We are using CATS. For the purpose of available hours of an employee only the total of a week is needed. So for instance 25 h/week. We set up a week workschedule 25h/week with day schedule of 5 hours per day (hours evenly spread over the 25 hour week). However, I run into the problem that when I want to enter a leave in infotype 2001 for a certain day only 5 hours is allowed. But I need/want to enter 8 hours in infotype 2001 (user works 8, 8, 4, 5, 0).
If it works in infotype 2001 then it will also work in CAT2 and CAT6. Can anyone explain me how to set this up. I checked the following:
V_001P_D- Group Personnel Subareas for Attendances and Absences
V_T554S-Define Absence Types
V_554S_O - Determine Entry Screens and Time Constraint Classes
V_T551C - Define Counting Classes for the Period Work Schedule
V_503_E -Group Employee Subgroups for Time Quotas
V_001P_I - Group Personnel Subareas for Time Quotas
V_556R_B- Deduction rules for absence quotas
T556C- Counting rule
V_554S_Q - Assign Counting Rules to Absence Types
V_554Y_B and table V_T554Y
But I got lost somewhere in the tables above, the entries seem fine. I thought I had it with table V_554S_O where I set the availability on 9, but that did not help.  The field "whole day" (P2001-ALLDF) is grayed out next to the field number of absence hours (P2001-STDAZ). We only us HR for CATS purposes.
I think I'm overlooking something for a particular setting in one of the above tables? I'm not an HR consultant so .... tabel V_556R_B is a very cryptic one for me. Further in table T556C I checked and unchecked "Work according to daily work schedule", but still no effect, also other combinations..... Also this table T556C I do not understand....
What I only need is specfic settings so that I can enter more absence hours in 2001 then in the workschedule is permitted. No updates in any other infotypes are necessary. From the help documentation it seems possible, but I don't seem to get it working....
Thanks in advance.
Kind regards
Mirko
Edited by: Mirko Polisini on Feb 8, 2009 9:50 PM

Hello,
We need to implement HR as lean en mean as possible, so time evaluation is no issue. Just want to post 0190 (Leave) in infotype 2001, 8 hours for a workschedule day that for instance only has 5 hours. Else user needs to create 2 lines in CAT2, 5 hours and another on same day with 3 hours. During CAT6 I get the problem that the 3 hours cannot be posted, besides the fact that this workaround is very userunfriendly.
Hoping that setting up infotype 2003 is not necessary, makes just things more complex (HR is just a means to an end for using CATS). Does it mean that I then need to create and absence type that is attached to infotype 2003? How does it work?
Thanks in advance for your help.
Kind regards,
Mirko

Similar Messages

  • Curve fitting: Taking standard deviation into account

    Hi,
    Using LabView and Curvefitting. Following situation:
    I have 15points including their standard deviation. I also have set up my curvefitting with my individual gaussian fitting. Basically the fitting looks good.
    But how can i tell labview to take care about my already calculated standard deviation.
    I always compare it with my OriginPro fitting (same gaussian equation). If I only take my data X and Y I get the same results.
    But when I also indicate my standard deviation (in Origin), meaning X, Y and +-Y I get a more realistic result.
    And that is what I would like to do with LabView aswell but there is no possibility to take my +-Y in account, isn't it?
    (And no, the Origin VIs for LabView do not offer me this aswell. At least I don't see it )
    Anyone a hint?
    Thanks in advance
    Solved!
    Go to Solution.

    altenbach wrote:
    What is the "CurveFitting SubVi"?
    sorry, meaning CurveFitting Express.vi
    I have an equation like: a+b*10^(-c*(x-x0)^2)
    a, b are offsets. x0 is the center of my gaussian curve. and i'm interested in c which describes the width of the gaussian function.
    please have a look to the attached file:
    - the red dots are mmy data plus the standard deviation (white dots)
    - the green fitting curve is labview using the CurveFittingExpress
    - the yellow fitting curve is using LabView Non-Linear Fitting with weigthing
    - the blue fitting curve is the output I get using OriginPro. As you could see Origin is the only one taking care about the points at the edge (fitting inside the standard deviation)
    that means in terms of c:
    labview: 0.089
    origin: 0.053
    x0 is kinda similar. a,b, are different.
    that's it.
    Attachments:
    Capture.PNG ‏58 KB

  • Table of contents file not taking book files into account

    Hi everyone,
    I've used Indesign's book panel to manage the chapters in a book that I've typeset. I set up the table of contents style (in a TOC document which is part of the books panel) and made sure that it used all the book chapters when compiling the table of contents by checking the option in the TOC styles diaglogue box.
    For some reason, the table of contents is ignoring all of the styles in the chapter files so it's not including anything in the table of contents other than a few headings that are within the file that contains the table of contents.
    I'm noticing that Indesign is creating a whole lot of duplicate files with a string of numbers appended to the file name, eg.
    Newbook_Cha531549083577
    These seem to duplicates of the chapter files but I have no idea why Indesign is creating them so I'm wondering whether I've got some corruption happening and whether this may be causing the problem with the table of contents.
    Has anyone had a similar problem and if yes, is there any solution?
    Really appreciate any advice.

    Peter,
    I'm having the same problem as gwh. The TOC won't go beyond the first document. All my style names are the same. I don't have style groups.
    To make the book I began with one long document that included all the chapters. I broke it into chapters by copying and pasting into new .indd documents (each one created by Save As from the first) and adding all those documents to the book.
    Generating the TOC from the one long .indd document works perfectly. I just can't get it to generate from the book (.indb) doc.
    I have all the documents in the book open. I have the first one active (in front). I generate the TOC, and I get only the entries for the first document. Here's a screenshot of my TOC box. I must be missing something really simple, huh?  (I'm using CS5)

  • Dynamic availability check not taking reservation accumulation into account

    We have 2 production orders for which the availability check had been done and situation is
    Finished good has 1 component and the Plant stock of the component is 99 EA.No other receipts are in place.
    Order1 is for quantity of 100 EA
    Order2(at a later date than order1) is 1 EA
    Post availaility check using COHV, Order1 is confirmed for 99 EA and is with MACM status and order2 has no commitment and is with MSPT status.
    Dynamic availability check for CO27 in OMCP config points to the same checking rule we used during the intial material availabillity check.
    In the Movement type config 261 movement type is assigned to dynamic avl.check - F  Message in any case: E mess. for non-avail., otherw. S mess.
    When we execute CO27 individually for the orders we can trap the error as per availability check commitments as we have seen earlier.
    But when we try to input both orders together in CO27 and do a pick list confirmation the second order gets the component issue with the first one not getting posted (expected to be partially to the tune of 99 EA) thereby violating the availability check results ultimately.
    Request your help in knowing whether this is the SAP design or am i missing some thing else?

    Query posted in the PP Forum and hence this is closed.

  • Dynamic vailability check not taking Reservation accumulation into account

    Hi,
    We have 2 production orders for which the availability check has been done initially and the situation is
    Finished good has 1 component and the Plant stock of the component is 99 EA.No other receipts are in place.
    Order1 for FG is for quantity of 100 EA
    Order2 for the FG (at a later date than order1) is 1 EA
    Post availaility check using COHV, Order1 is confirmed for 99 EA and is with MACM status and order2 has no commitment and is with MSPT status.
    Dynamic availability check for CO27 in OMCP config points to the same checking rule we used during the intial material availabillity check.
    In the Movement type config 261 movement type is assigned to dynamic avl.check - F Message in any case: E mess. for non-avail., otherw. S mess.
    When we execute CO27 individually for the orders we can trap the error as per availability check commitments as we have seen earlier.
    But when we try to input both orders together in CO27 and do a pick list confirmation the second order gets the component issue with the first one not getting posted (expected to be partially to the tune of 99 EA) thereby violating the availability check results ultimately.
    Request your help in knowing whether this is the SAP design or am i missing some thing else?
    Regards,
    SRK

    Query posted in the PP Forum and hence this is closed.

  • Leave approved in Portal is not getting updated in Infotype 2001

    Hello,
    I am using the standard WF - WS12300111 for Leave Request in the Portal.
    The workflow is working fine in the portal; Manager could approve / reject the leave request in MSS and it is updating the portal Team calendar and ESS Employee Leave details.
    However the approved leave is not getting updated in the Absence infotype 2001 in the back-end system.
    Could you help ? 
    Kind Regards
    Desy

    Program (SE38) - RPTARQPOST has to be scheduled in order to update the status of leave requests and post to PA2001 after they have been approved.
    Is there any other way ?

  • To Complete the task without taking complete action in BPM worklist.

    In my project ,there is one requirement that to complete the task without taking complete action in BPM worklist.
    So I am trying to acheive this using JAva API of BPM worklist.
    For that I have followed the approach given in below link
    http://technology.amis.nl/2007/02/invoking-bpel-worklist-api-from-remote-server-with-java/
    Created java application and imported all the required libraries and jars.
    while running this application it is giving following error
    NoClassDefFoundError: oracle/j2ee/ws/common/jaxws/ServiceDelegateImpl
    This is due to absence of 'ServiceDelegateImpl.class' which should be present in webclient.jar ,
    I have also added the same jar from jdeveloper\webservices\lib folder.
    but the thing is ServiceDelegateImpl class is missing in webclient.jar.
    I have downloaded the same jar from internet and tried various versions also.
    still the problem persists.
    Which jar should I add ? or any other configutation is required ?
    Am I following correct approach?
    Any suggestions on other approach would be appreciated.
    Thanks in advance.

    Hi Marc,
    You can set the task Process Owner (i.e. TaskProcessOwner) to the group which Bowman and
    Laura belong to from SharePoint Designer, then they should be able to complete the re-assigned task.
    http://www.fourbuckeyes.com/2013/06/07/task-delegation-in-sharepoint-2010-approval-workflows/
    http://community.rightpoint.com/blogs/viewpoint/archive/2012/04/17/sharepoint-designer-2010-workflow-advanced-properties.aspx
    Thanks
    Daniel Yang
    TechNet Community Support

  • RE:ABAP HR infotype 2001 document number

    Hello All,
    When we save a record in infotype 2001 (Absence) in Pa30 it creates internally a document  number.I wanted to know is there any Tcode where we can see this document number? I know the BAPI name but i want the tcode where we can see the document number. Please help me regarding this.
    Thanks and Regards.
    Salish.

    Hi,
    The document number generated for each record would get stored in the database table PA2001 under the field AWREF for that record.
    Hope this helps.
    Thanks,
    Harini
    Edited by: Harini Gopinath on Oct 20, 2009 6:17 PM

  • FMLA standard hours infotype 2001 not editable when working with date range

    Hi All,
    The issue described below arises at the Juncture between FMLA Workbench and Absence Infotype IT2001.
    When we try to tie a FMLA Request to Absences the process takes us to the Infotype PA2001 screen wherein we would like the Absence Hours Field to be Editable so that we could enter Hours (less than full day).
    The process works fine when the FMLA absence is for a single day, i.e. if an employee availed a FMLA leave on a day (whether full day or part of a day) the Absence Hours field (PA2001-STDAZ) is editable and the user can enter any number of hours of his choice.
    But the process faces a glitch when the FMLA absence spans over a period of time (i.e. an employee availed a FMLA leave for over a period wherein each day may or may not be a full day absence, in this scenario it would be best if the system allow the user to enter Absence Hours so that the User could enter the exact number of Absence hours correctly. But unfortunately, when an absence spans multiple days the Infotype 2001 screen dynamically turns the Absence Hours field (PA2001-STDAZ) uneditable (grayed out) and the system forcefully enters hours equal to the sum of the work schedule hours for each working day covered in the span of period for which we are trying to enter FMLA Absence Hours.
    I have used the USER EXIT and the BADI route and tried to change the Screen Table to editable, but with no luck.
    Wondering, if anyone of you could help me out of this glitch.
    Thanks in Advance.

    Hi,
       I don't think this is possible.
       You cannot make the Hours field editable for a date range.
       I don't think its feasible to enter absence hours on a day basis given a date range.
       Better think of creating a custom infotype to enter absence hours .
       (Design would be : based on the date range entered , say 01.01.2011 to 05.01.2011 , you should get five input enabled
         boxes(dynamically) for five days to enter the absence hours , this is not possible in standard infotype ..... )
    Regards,
    Srini.

  • INFOTYPE 2001 AND 2002

    When i book absence in infotype 2001 or book an attendance in infotype 2002, if i put 6.51, the system automatically changes it to 6.52 hrs. I just want the system to take 6.51. How is this possible. Can this be done through configuration. Please help
    Thanks

    hi,
    This Absence Hours is changing automatically to accomodate the absence start Time and End Time.
    Say in your eg,
    I assume Personal workshedule start Date - End date iis 8.00 - 17.00.
    You are trying to input6.51,system will automatically change to 6.52 to get the correct start Time and End Time.(eg: 08:00 - 15:31)
    Manoj.

  • PCL4 TABLE LOG FOR INFOTYPE 2001 IS NOT WORKING IN QUA 070 CLIENT

    Heloo,
    Could some one let me know the ways to capture the log of infotype 2001.
    I have used PCL4 table to capture all the changes made to INFTY 2001.
    This is working fine in DEV 070.
    But not working in QUA 070.
    Could someone let me know what is the problem and the solution.
    Thanks a lot for your efforts.

    Hi Lata!
    I created the absences (T554S):
    Ps grouping, Absence type text
    04,0100 VACATION WORKIN DAYS (quota working fine)
    34,0100 VACATION NATURAL DAYS
    When I check your steps I have this information
    1. Absence type screen no. should be 2001.
    I have checked in table T554S.
    Screen number quota working fine: 2001
    Screen number quota working bad: 2001
    2. Quota deduction should be selected in V_554S_Q table
    Check quota deduction quota working fine: is checked
    Check quota deduction quota working bad: is checked
    3. Check that in counting rule you have assigned correct deduction rule.
    Counting rule for quota working fine: is 010
    Counting rule for quota working bad: is 030
    The counting rule 030 is created for me, maybe this is the problem is a similar copy of the rule 010. It has different conditions because in Psgroup "04" the vacations are working days but in group "34" the vacations are natural days.
    4. In deduction rule check whether correct quota no. you have maintained.
    In deduction rule working fine the absence quota type is 10, standar leave, days
    In deduction rule working bad the absence quota type is 30,                        ,days
    I've checked the absence quota type and are similars:
    In 10 absence quota type
    ESG Time quota types: 1
    PS Grpg tm Quota Typ: 01
    Absence quota type: 10
    Time/measurement unit: Days
    Time constraint class: 02
    In 30 absence quota type:
    ESG Time quota types: 3
    PS Grpg tm Quota Typ: 02
    Absence quota type: 30
    Time/measurement unit: Days
    Time constraint class: 02
    What's wrong?
    Kind regards,
    Julian

  • IT2001 error, no time constraint reachion for infotype 2001 with tm const00

    Dear Seriors,
    When I try to add any absence, it show the below given error message (red colour), but if I hit the enter button it allows me to mark absence.
    no time constraint reachion for infotype 2001 with time constraint class 001
    What might be the reason?
    Regards
    ET

    The time constraint class is used to check for collisions between Time Management infotypes (2001 to 2012). It allows you to specify different regulations for checking for collisions between individual subtypes.
    The views Time Constraint Reaction to Time Management Infotypes (V_554Y_B) and Global Time Constraint Reaction (V_T554Y) contain rules for the collision check.
    Please explore on this.

  • Infotype 82 linked to infotype 2001

    Hi everibody, 
    can someone tell me whether it is possible to customize infotype 2001, linked to infotype 82?
    In fact in the infotype only fields AWART, BEGDA and ENDDA are displaied, and in this context we can only manage the "full day" vacation.
    We'd rather like to manage the single vacation hours, using the input field STDAZ in the table control of the infotype 2001, linked to infotype 82.
    Can someone give me suggestions about this?
    Thank you in advance
    Cinzia

    If i understand correctly, you want to be able to input hours instead of full days in infotype 82 right ? In order to be achieved this will definitely need some coding.
    I have created an infotype in a client for work accidents, similar to 82 but with table control for the absences associated to an accident, so the accident itself is in infotype 9127 (in this case) and then the absences associated with this accident are in 2001 and this association i used a field in 2001 that wasn't used for anything (AWREF i think). So i generated a unique number through an interval and saved it in infty 9127 and then in the corresponding absence in 2001 in field AWREF.
    In your case, since you want to use this standard infotype, on way to do this might be creating an adittional field in infotype 82 using PM01 to enhance the infotype. This field would be "hours". Then using BADI HRPAD000INFTY you can get the creation of infotype 2001 for this absence and use that value through seting a parameters or passing it in the PSPAR structure for example. There are a few ways to achieve this, but still it will need some coding.
    Edited by: Pedro Guarita on Oct 13, 2010 2:08 PM

  • Query in infotype 2001(Absenses)  and 2005(Overtime)

    Dear Freinds,
                   I have one query in infotype 2001(Absenses) when iam entering the  the absence hours  as 2 hours it is defaulting the start date time (beguz) 9.00 and end time (enduz) 11.00 ....which my user is not accepting ......they wantedn it to act like the overtime (2005) it is deducting the end of the time 18.00 (6.00p.m) as the Beguz as 18.00 pm and Enduz as 20.00 pm..........i would like to know can we change for the 2001 also in this way .......by using the concept of 2005 in the user exit EXIT_SAPFP50M_002  or in the BADI BAdI HRPAD00INFTY , however i am unable to change , could any one please let  me know if you  has implemented please let me know .
    thanks & regards
    madhuri

    Hi,
    i don; think we can modify IT2001, since we have IT2005 to enter Overtime.
    It is better to use IT2005 for overtime. One more thing here, how can we treat absence hours as Ovetime hours?
    thanks,
    vasu.

  • Disable Delete Button for infotype 2001 subtype 0025

    I want to Disable Delete Button for infotype 2001 subtype 0025 only in PA30/61.
    Is there any EXIT available

    Hi
    Try it .
    Somebody already given this type of answers.
    Pls first use Search then post.
    Well FYI,
    <b>There is a standard User Exit for PA30 / 40 for PBO and PAI events.
    ZXPADU01 for PBO and
    ZXPADU02 for PAI events.
    By writing proper code in here for the IT2001, you can write your rules.
    PBAS0001 ( PA: Pers.Admin./Recruitment: Default values and checks ),</b>
    Manoj Shakya.

Maybe you are looking for

  • Job cancelled While loading data from DSO to CUBE using DTP

    Hi All,   while i am loading data frm DSO to CUBE the job load is getting cancelled. in the job overview i got the following messages     SYST: Date 00/01/0000 not expected.    Job cancelled after system exception ERROR_MESSAGE wt can be the reason f

  • How to insert Data in a table from iFS.

    Hi, We have an application that communicates with the customer through iFS. I am asked to add a new functionality to that application that will populate a table in the database with customer id, customer inserted file name and internal file name afte

  • Doesn't recognize the flash player

    i installed flash player long time ago, and it worked perfect. But recently whenever i try to run a flash based aplication says: "this application needs flash, flash is not installed". I didn't paid much attention, because i was using firefox plugin,

  • Help with Applescript, please?

    I am working on a script that will allow me to copy/move folders from my Mac to a Windows shared drive, without overwriting the entire existing folder and losing other files that may already exist in it. The commands work fine from a terminal, the pr

  • Network won't load; states 'Loading Network', but never does. Help.

    After returning home after a house refubishment, had to get TalkTalk engineers to reconnect me.  Now have internet and Fibre Optic access.  But, as above, when I click on the Network icon, it keeps saying: Loading Network ...'  But never does.  There