Acquire Analog and Digital inputs at the same time with 6025E card

I have 6025E DAQ card, all the analog channels are used
up. There are several digital signals, such as flowmeter. Can I acquire both kinds of data at the same time with my 6025E card? Thanks for your help.

I suggest you search the examples that ship with LV
Digital
Find Examples>>>Hardware Input and Output>>>Digital Input and Output>>>8255
for doing each type of I/O seperately.
When you have found two examples. Just try to run the two at the rate use need in your final app.
Post follow-ups Q's here. I am not personally familiar with that deveice so I can not speak from experience.
I would generally expect that if you sample rate is low (i.e. <10Hz) you maybe happy with the results. If you want to run faster or have the PC do something else at the same time, the timing of the signals form the DIO lines may be suspect.
So...
It depends.
Trying to help,
Ben
Ben Rayner
I am currently active on.. MainStream Preppers
Rayner's Ridge is under construction

Similar Messages

  • Airtunes - Analog and Digital output at the same time?

    Howdy,
    This may seem strange to ask, but can the Airport Express output audio in digital and analog formats at the same time? Is there a strange splitter cable that could do this for me?
    I recently learned that most AV receivers with digital inputs cannot output digital sources to their analog zone 2 outputs. The usual work-around is to connect their digital sources to the receiver by both analog and digital cables.
    Mikael

    I just learned the same thing. Does connecting the digital and analog connections to your reciever work ? Did you connect them to the same source or assign different sources for each? Thanks,

  • My ipod has a black screen.  I have tried to hold the sleep/off button and menu button at the same time with no luck.   I connected to my computer and tried restore on itunes -  still with a black screen a voice said "screen locked'  code 542

    My ipod has a black screen.  I have tried to hold the sleep/off button and menu button at the same time with no luck.   I connected to my computer and tried restore on itunes -  still with a black screen a voice said "screen locked'  code 542

    Is the iPad charged?  Plug it in with the charger/wall outlet for half an hour and try again to reboot by holding both the power and home buttons until the apple logo appears.

  • Write to serial port and digital port at the same time

    hello,
    I need to write to the digital port and the serial port at the same time. Right now I have the two vi's (to write to the serial port, write to the digital port) in the sequence structure. First I write the digital port, then write the serial port. Using the oscilloscope, the interval between these two executions is 10 ms; and I need to reduce this interval to as small as possible. I would appreciate help in any way. Thank you.

    Hello;
    This is a little tricky. Since the transition from one sequence to another is completely Software timed, and windows manages all tasks that are running at one given time, there isn't a method to reduce that transition time.
    The most you can do is try to optimize your code so all the time expent on the transition is due only to the task management.
    Hope this helps.
    Filipe A.
    Applications Engineer
    National Instruments

  • Why can't I use Airplay/Bluetooth audio output and Guitar input at the same time?

    Just trying to understand why it is not possible to use one of the 3rd party guitar input devices and have AirPlay/Bluetooth output turned on at the same time.  it would be very nice to be able to play wirelessely to the stereo instead of adding yet another cable to the mix.
    Thanks

    I found the answer:
    Use GarageBand for iOS with external output devices
    You can use GarageBand for iOS with external devices, including AirPlay, Bluetooth, and HDMI-equipped media devices. When using any of these devices there is no support of audio input.
    http://support.apple.com/kb/HT4622

  • Can I use Lightroom on my mac and my pc at the same time with only one subscription?

    Hello everyone,
    for five months now I have a Creative Cloud subscription for Lightroom and Photoshop. Till now I was just using it on my PC. Now I've bought me a MAC and would like to install Lightroom on the MAC either. Do I need a second subscription for MAC or can I use my subscription on the MAC and PC simultaneously?
    thx for feedback

    If you are asking if you can be running the subscription software on the two machines at the same time, the answer to that is no.  Per your license you can only be using one of the installations at a given time.
    If you are asking if you can have the software installed and capable of being used on both machines then the answer is yes... you just cannot have both machines in use  running the subscription software at the same time.

  • Digital input and digital output at the same time

    Hi all
    I have a PCI-6503 board. I have done 2 task that run simultaneously: the first one is port0_16 output and the second one is port2 input.
    I get sometimes (not every times...this is strange...) error-200587 saying:
    'Requested operation could not be performed, because the specified digital lines are either reserved or the device is not present in NI-DAQmx.
    It is possible that these lines are reserved by another task, the device is being used through the Traditional NI-DAQ interface, or the device is being reset. You might also get the error if the specified resource is currently in use by LabVIEW network variables bound to the DAQ Channel, or if the DAQ Channel is being used in any OPC Client software.
    If you are using these lines with another task, wait for the task to complete.  If you are using the device through the Traditional NI-DAQ interface, and you want to use it with NI-DAQmx, reset (initialize) the device using the Traditional NI-DAQ interface. If you are resetting the device, wait for the reset to finish.'
    In the attached VI i have recreated the basic structure of my real VI (the error is present even here of course...).
    How can i do?
    I want to have both digital input and digital output with the same PCI-6503 every single cycle... Is it possible?
    Please help me!!!
    Kind regards.
    I love the smell of napalm in the morning
    Attachments:
    DIO simultaneously error.vi ‏31 KB

    Hello Maverick,
    Did you have any luck with the example Raven sent you?
    In Raven's example, it properly passes the DAQmx task from one SubVI to another to avoid having to open the task again. These errors are likely to occur when you have multiple DAQmx calls in a VI that call the same task again without clearing the previously opened task. If at any given time you try to open a task that already is being used, you might receive an error "resource is reserved"... similar to your original example.
    If you are interested, here is an awesome link that gives a detailed explanation of the LabVIEW dataflow paradigm
    Learn 10 Functions in NI-DAQmx and Handle 80 Percent of Your Data Acquisition Applications
    Thanks and good luck!
    Jordan Randall
    National Instruments Italy

  • How to read two counters and writing AO at the same time with 6024?

    I use Labview to read two quadrature encoder outputs and I use the two
    counters
    of 6024E for this. I can read the encoders continuously. I also want to
    send an
    analog output with a period of 30 miliseconds
    while the reading of encoders is continuouing at the background. How can I
    do
    this. I searched the NI discussion forums and found that my device have
    only 1 DMA channel. Is it possible to overcome the problem using
    interrupt??(set device information.vi) Is there any example code about this
    problem?
    Thanks a lot.."

    Hi Ress,
    I think you might have asked this question twice by mistake. Following is the link to the one that was answered:
    http://exchange.ni.com/servlet/Redirect?id=12017430 .
    Thanks!
    Serges Lemo
    Application Engineer
    National Instruments

  • Bluetooth keyboard K810 and mouse T630 at the same time, repeating keys and mouse starts to stutter

    I use a Lenovo Thinkpad Tablet 2, Windows 8.1(core edition), x86 (32bit).
    If I pair a Bluetooth keyboard K810 and mouse T630 at the same time, with Wifi On, the keyboard starts repeating the keys and the mouse starts to stutter. Especially if WiFi is under load (when downloading something).
    This doesn’t happens if I pair only the keyboard, or if I pair mouse and keyboard with Wifi OFF.
    If I pair a Bluetooth keyboard and use a USB mouse with Wifi ON, everything works fine.
    If I pair a Bluetooth mouse and use a USB keyboard with Wifi ON, everything works fine.
    I think it is an issue with two Bluetooth devices paired at the same time with Wifi ON.
    So here is a summary:
    BT mouse and BT keyboard / Wifi ON ----> repeating chars and the mouse starts to stutter (bug)
    BT mouse and BT keyboard / Wifi OFF ----> works fine
    Only BT keyboard / Wifi ON ----> works fine
    Only BT mouse / Wifi ON ----> works fine
    USB mouse and BT keyboard / Wifi ON ----> works fine
    USB keyboard and BT mouse / Wifi ON ----> works fine
    Where is the problem? Is there any solution?
    Solved!
    Go to Solution.

    I have solved the problem. In the Wlan-Drives-Settings there is the "Bluetooth Collaboration" option. I put the value to "Disable" and now works everything like charm.
    Best regards, jC
    Broadcom manual:
    Bluetooth Collaboration
    Bluetooth Collaboration enables general purpose input/output transmit suppression protocol between the IEEE 802.11 media access control (MAC) and an external Bluetooth chip to minimize transmit interference. Bluetooth Collaboration is enabled by default.

  • How can i synchronize analog output and analog input timings to generate and measure voltage at the same time.

    how can i synchronize analog output and analog input timings to generate and measure voltage at the same time.

    Read this Tutorial
    http://zone.ni.com/devzone/cda/tut/p/id/3615#toc3
    And also refer to this link where You have repeated this question.
    PS: Please stick to one thread. That way, its easier to keep track of your query and answers

  • TS3280 How can i enable both paired bluetooth and ios keyboard input at the same time?

    How can i enable both paired bluetooth and ios keyboard input at the same time?
    This is needed for the app im working on. Need some user input via keypad as well as scanner input via a paired bluetooth scanner.

    You probably should not be using a keyboard bluetooth profile for a scanner, I am not a developer for apple so do not know the location for you to find out the correct profile you should be using for an input device that is not a keyboard. Sorry,
    I am sure if you navigate the apple developer site you will probaly finmd what you're looking for.
    https://developer.apple.com

  • How can I do to acquire and save date in the same time and in the same file when I run continual my VI without interrupti​on.

    I've attached a VI that I am using to acquire amplitude from Spectrum analyzerse. I tried to connect amplitude ouput to the VI Write Characters To File.vi and Write to Spreadsheet File.vi. Unfortunately when I run continual this VI without interruption, labview ask me many time to enter a new file name to save a new value.
    So, How can I do to aquire and save date in the same time and in the same file when I run continual my VI for example during 10 min.
    Thank you in advance.
    Regards,
    Attachments:
    HP8563E_Query_Amplitude.vi ‏37 KB

    Hi,
    Your VI does work perfectly. Unfortunately this not what I want to do. I've made error in my last comment. I am so sorry for this.
    So I explain to you again what I want to do exactly. I want to acquire amplitude along road by my vehicle. I want to use wheel signal coming from vehicle to measure distance along road. Then I acquire 1 amplitude each 60 inches from spectrum analyzer.
    I acquire from PC parallel port a coded wheel signal coming from vehicle (each period of the signal corresponds to 12 Inches). Figure attached shows the numeric signal coming from vehicle, and the corresponding values “120” and “88” that I can read from In Port vi.
    So I want to acquire 1 time amplitude from spectrum analyser each 5
    period of the signal that I am acquiring from parallel port.
    So fist I have to find how can I count the number of period from reading the values “120” and “88” that I am acquiring from In Port (I don’t know the way to count a number of period from reading values “120” and “88”).
    Here is a new algorithm.
    1) i=0 (counter: number of period)
    2) I read value from In Port
    3) If I acquire a period
    i= i+1 (another period)
    4) If i is multiple of 5 (If I read 5 period)
    acquire 1 time amplitude and write to the same
    file this amplitude and the corresponding distance
    Distance = 12*i). Remember each period of signal
    Corresponds to 12 Inches).i has to take these
    values: 5,10,15,20,25,35,40,45,50,55,60............
    5) Back to 2 if not stop.
    Thank you very much for helping me.
    Regards,
    Attachments:
    Acquire_Amplitude_00.vi ‏59 KB
    Figure_Algorithm.doc ‏26 KB

  • AirPlay Mirroring and Output via Digital Adapter at the same time

    Hello,
    Is it possible to use AirPlay Mirroring to an apple tv and the digital Adapter at the same time?
    We want to get the Screen on a beamer and a tv at the same moment.
    If this isn't possible are there any chances to get AirPlay mirroring working on two Apple TVs at the same time?
    We are using the newest iPad Air
    Greets

    Unfortunately not. One output is supported at a time. But perhaps you can use some sort of an HDMI signal splitter? I've not tried it, and perhaps it won't work at all, but you might try outputing directly to a splitter that then can be connected to both a TV and beamer.

  • Problem connecting Firewire device and external HD at the same time

    Hi. I'm attempting to record digital audio through a Presonus Firepod A/D interface via a Firewire 400 to 800 cable connected to one of the Firewire 800 ports on a mid-2010 Mac Pro running Snow Leopard.
    The problem is that if I have an external HD connected to one of the other Firewire 800 ports on the computer and powered on at the same time, the connection to the Presonus Firewire device is not recognized by the Mac Pro. Not only that, performance of the Mac Pro is affected adversely and System Profiler is unable to list any Firewire devices. If I turn the external HD off, the Presonus device is recognized and listed in System Profiler and the machine runs fine. I'm able to connect two external hard drives via separate Firewire 800 ports on the Mac Pro and both drives mount w/ no problem. It's only when I try to connect one of the external HDs and the Presonus audio device at the same time that the problem occurs.
    I used this same arrangement on a PowerMac G5 running Tiger w/ no problems whatsoever. If the 400 to 800 cable is bad, I would think it wouldn't work at all, but it does when only the Presonus Firepod is connected and powered on. Any ideas?

    Have done more research and apparently this is not an uncommon problem: overloading the Firewire bus when connecting an audio device along with an additional device like an external hard drive. As I understand it now, audio signal is a bandwidth hog and the solution is to get a Firewire PCIe card which will have its own independent Firewire bus and which I'll use exclusively for my audio device.

  • Itrip and car charger at the same time?

    I've noticed that all the iTrips for the 5th generation video iPod connect via the dock connector at the bottom. Is it possible to use an in car charger and an iTrip at the same time, as they both connect via the same input?
    Thanks

    That is not possible, but they do make an iTrip specifically for the car. It chargers at the same time. Check Griffin's website.
    My friend hasa it and loves it. The charger actually helps the iTrip get a stronger signal.

Maybe you are looking for