Adapter message monitoring: message in HOLD

Hi,
since we changed a scenario:
a) old scenario: R/3 --> XI --> BPM --> XI  --> FTP
b) new scenario R/3 --> XI   --> FTP
the messages stuck in adapter message monitoring.
Message-Interface is the same, CC is the same; just the way through BPM was canceled.
any suggestions?
Thanks
Regards Mario

Hi Mario,
messages are in status HOLD, when they need to be sent in exact order (EOIO), and an error occured in one (or more) queues. When you solve this error, restart the first message from the queue after this error and the items will be processed.
How to do that:
Go to messaging system servlet, find your message (in hold status) and click the Eye icon - Details. Now read the Conversation ID value - which is your queue ID.
Go to RWB, message monitoring, choose adapter engine( from combobox)-> display.Now click additional criteria, put the value of Conversation ID to conversation ID textbox. Start search. You'll see a lot of messages there in hold status I think, But find the one in System Error status. Try to resend this message, if it will not change its status (will still be in in System error), cancel it. Now restart first message from the queue, which was after this wrong one.
This should release the queue and process items.
If any questions, let me know.
Peter

Similar Messages

  • In Message Monitoring Message showing holding status

    Hi
    Can anyone solve this problem.Its urgent for me.
    My scenario is IDoc->XI->FILE
    The file i am trying to generate is an xml file which i am dropping in XI application server using File system.
    The problem is when i am going to see the message using transaction SXMB_MONI the perticular message interface is showing waiting for acknowladgement status .
    But in message monitoring in runtime workbench the it is showing following status:
    Adapter Engine
    <b>Holding</b>
    18.11.2005 05:42:09    
    CORP_SAP_DR2_030 http://limited.com/usa/sap_appl/retail/VendorsSAPAPOToMANU
    MIIA_Create  
    BS_MANU
    I am in SP14.
    Also the output xml file is not getting created in the XI application server.
    Please let me know the solution.
    Thanks
    Debraj Roy

    Hi Debraj
    HOLDING is a status which occurs normally for EOIO (Exactly Once In Order), so your message is set to Holding means some earlier message has not gone through. So until those messages are through this message will be in HOLDING state.
    Have a look at this link which explains how to handle such scenarios.
    http://help.sap.com/saphelp_nw04/helpdata/en/49/e3fb40ef74f823e10000000a155106/content.htm
    cheers
    Sameer
    Assign points if it helped you

  • In Message Monitoring Message showing Error:Message

    Hi
    Can anyone solve this problem.Its urgent for me.
    My scenario is IDoc->XI->FILE
    The file i am trying to generate is an xml file which i am dropping in XI application server using File system.
    The problem is when i am going to see the message using transaction SXMB_MONI the perticular message interface is showing waiting for acknowladgement status .
    But in message monitoring in runtime workbench the it is showing following status:
    Adapter Engine
    <b>Holding</b>
    18.11.2005 05:42:09    
    CORP_SAP_DR2_030 http://limited.com/usa/sap_appl/retail/VendorsSAPAPOToMANU
    MIIA_Create  
    BS_MANU
    I am in SP14.
    Also the output xml file is not getting created in the XI application server.
    Please let me know the solution.
    Thanks
    Debraj Roy

    hi debraj..
    is ur mesage ie sxmb_moni in red staus or scheduled status...??
    if in scheduled cud be errors with queues ...delete ur queues with tcodes : smq1 and smq2...
    and also hopefully u must have configured ur idoc correctly..
    https://websmp101.sap-ag.de/~form/sapnet?_SHORTKEY=01200252310000071155&_SCENARIO=01100035870000000202
    regards..
    vishal

  • All messages on hold in message monitoring

    Hi,
    If all of sudden (SOAP to idoc) ..for all the messages in message monitoring is on HOLDING status for all the interfaces.
    These interfaces were working fine earlier.
    In adapter monitoring , adapters are fine.
    i could not see anything SMq transaction also.
    what are the possiblities to cause this kind of error?
    Thanks

    Hi Bhavesh,
    It is exactly once in Order.
    This is really useful info which u send.
    I could not find conversion id and sequential number as stefan mentioned in that blog in my message monitoring in config. table columns(in extended filter criteria)
    But already  i tried to cancel the those messages as well as resend  but i could not do.
    I guess my user do not have access to that.
    Any other inputs/useful blogs?
    Thanks
    Edited by: Raja on Aug 14, 2008 5:47 PM
    Edited by: Raja on Aug 14, 2008 5:52 PM

  • SOAP messages not visible in RWB - Message Monitoring - Adapter Engine

    Hi,
    following scenario:
    ERP is sending IDocs to PI.
    Within PI an integration process sends the IDoc data through a SOAP (WS) receiver channel to a system far far away.
    In RWB -> Communication Channel Monitoring I can see all delivered messages selecting my SOAP channel.
    But:
    I can´t see the SOAP messages in RWB -> Message Monitoring -> Messages of Adapter Engine.
    In RWB -> Message Monitoring -> Messages of Integration Engine I only see SOAP messages with status "Error".
    Successful column is empty.
    Do I have to adjust some system / monitoring parameters also seeing SOAP messages in RWB->Message Monitoring?
    Thanks in advance,
    André

    Hi Ravi,
    thanks.
    But there are thousands of successful messages delivered to the receiver.
    These successful messages can only be seen in the Channel Monitoring.
    I can´t find these successful messages in Message Monitoring.
    Only some with status "Error" are displayed.
    Strange...
    Cheers,
    André

  • Data Persistency in Message Monitoring of RWB

    Hi All,
    I am dealing with Sync. Interfaces and need to monitor the messages from Message Monitoring.
    I have 2 Problems in the monitoring : -
    1.     I can only see the messages for last 2 hrs in Message Monitoring.
            Messages Older then 2 hours are not getting displayed.
    2.     Also if i am unable to see complete set messages in the 2 hr interval.I mean randomly                 
             messages are getting lost in message monitoring.
    Is there any setting we need to maintain for Message Monitoring?
    Helpful Answers will be rewarded points.
    Thanks & Regards,
    Zabiulla

    Hi
    have  a look at this SAP Note 1031773 - Activating the message overview in RWB message monitoring
    message struck in adapter eng.(RWB message monitoring)
    http://help.sap.com/saphelp_nw70/helpdata/EN/45/0ea84637643c0ae10000000a11466f/frameset.htm
    http://help.sap.com/saphelp_nw70/helpdata/EN/be/38f0d8cbfe11d2a5f80060087832f8/frameset.htm
    Thanks
    Edited by: Abhishek Agrahari on Jan 8, 2009 8:14 AM

  • Resend Message from Seeburger message monitoring

    Hi friends,
    I want to know that is there any possiblity of resending the message from Seeburger message monitoring tool.
    One of the messages failed due to a problem in sender ID.
    I want to resend this message. is it possible ?
    Note: Message send out successfully from communcation channel to AS2 adapter.
    Thanks
    Sunil.

    Hi Sunil,
       Please let me know what error you can see in Seeburger Workbench.
    In My view you can see the below type of error with State u201CError on send, will be retriedu201D
    If Any Message failed in AS2 Adapter may be due to any reason
    1. Wrong Sender/ Receiver ID
    2. Wrong URL
    3. Firewall rules are not in place
    4. Partner Production site is down and you are unable to connect to him
    Messages with above errors will appear with Success Flag in SXMB_MONI. But they will be caught by Seeburger Adapter and will be in the Error Status in SEEBURGER WORK BENCH
    The only way to find/restart those messages is go to Runtime Work Bench Messages Monitoring --> Messages form Component (Adapter Engine) ---> System Error Status.
    Any Message which failed in Seeburger Level can be seen only in Runtime Workbench.
    Regards,
    Rama.

  • Message status "Holding" - Message monitoring adapter framework

    Hello,
    We have some messages with the status "Holding" in a queue in the message monitoring in the adapter framework.
    Normally you have to restart the first message of that queue. The message with the status "system error". Unfortunately this message is not available anymore because it is older than 30 days and the retetion period is 30 days.
    I already read the blog about "[How to deal with stuck EOIO messages in the XI 3.0 Adapter Framework|http://www.sdn.sap.com/irj/scn/weblogs;jsessionid=(J2EE3417100)ID1887311350DB01819286872323159351End?blog=/pub/wlg/3566]"
    The blog does not mention what to do when the first message (sequential number) is not available anymore.
    Is it possible to restart the messages in the queue in that case?
    Thanks
    Kind regards
    Frank

    Unfortunately this message is not available anymore because it is older than 30 days and the retetion period is 30 days.
    I assume that the message was deleted.....in this case the next message in the queue will be blocking the queue....so try resending this message....even the blog mentions that you either solve the error or cancel the message....so now start from the second message....if possible solve the error for this message....if not possible to resolve then cancel it so that rest of the queue gets processed
    From the blog:
    Now the erroneous message is the first message in the display. You can look at the error reason, try to fix the problem and
    resend or cancel the message to release the queue.
    Regards,
    Abhishek.

  • Messages on Holding at Message Monitoring under Runtime Workbench

    Hello Colleagues,
    we have currently the problem that a lot of messages for some interfaces are in status Holding under Message Monitoring at Runtime Workbench for PI 7.1.
    I'm not able to resend the messages with status Holding as well as change status to cancel.
    Quality of Service for the Interfaces are Exactly Once in Order.
    I assume an error message blocks the queue and due to the fact we have Exactly Once in Order configured all following messages be in status Holding.
    Is my assumption right?
    But, I am not abel to find any messages in status error with blocks the queue!
    How can I solve that issue?
    Many thanks in advance!
    Jochen

    I assume an error message blocks the queue and due to the fact we have Exactly Once in Order
    configured all following messages be in status Holding.
    AE should have least number of EOIO messages at a given instance...otherwise Holding is what you get.....and holding is common with EOIO....so see if you can chagne the QoS of some messages to EO
    But, I am not abel to find any messages in status error with blocks the queue!
    Never you will get an error in SXMB_MONI....or the queue blocked....
    When your message goes out of IE...the corresposding message entry is marked with chequered flag...observe in MONI you will see this....however in AE the message can fail if not able to send to the target system....
    For some more understanding refer my answer in this thread:
    Re: Restarting Error's in SXMB_MONI
    Regards,
    Abhishek.

  • Message got struck in hold status in message monitoring.

    Hi SDNers,
                 I am doing Idoc to File scenario. I triggered an Idoc and it is successfully processed in XI and got struck in message monitoring with hold status.
                 After repetetive attempts of restarting the message, still it is in hold status.
                 Even if I tried to cancel the message, it is not cancelling as it is in hold status.
                Can anybody please help how to process the message or can anybody explain how to cancel the message from message monitoring, which is in hold status.
    Regards,
    Jayaram.G

    Hi,
    If the message that has not yet been delivered is not in error state, the problem cause is probably that the message is blocked in the QRFC queues of the Integration Engine.
    Check queue status
    Call the Integration Server and call transaction SMQR in the sender and receiver Integration Engine in the corresponding system client.
    Check the status of the scheduler and the status of the XBQ* and XBT* queues:
    u25CF     Inbound qQueues
    XBTI* (ExactlyOnce)
    XBQI* (ExactlyOnceInOrder)
    u25CF     Outbound queues
    XBTO* (ExactlyOnce)
    XBQO* (ExactlyOnceInOrder)
    u25CF     Acknowledgment queues
    XBTB* (ExactlyOnce)
    XBQB* (ExactlyOnceInOrder)
    u25CF     Large message queue
    XBTL* (ExactlyOnce)
    If the scheduler has the status Waiting, it is waiting for free work processes. This is why delays occur when XML messages are processed.
    If not all necessary queues are registered, you can search for queues with the name prefix above using transaction SMQ2. Use transaction SXMB_ADM to register the queues in this case.

  • Wrong port in FTP receiver adapter - no errors in message monitoring?

    Hello all
    We're on XI 3.0 SP16 and have created / configured a HTTP XML -> XI -> FTP Server scenario. In the receiver comm. channel (ftp) we had specified a wrong port number and always wondered, why we never got errors in message monitoring. Everything seemed to be processed correctly... but no file arrived on the FTP server (receiver) side!
    After correcting the wrong FTP port number in the receiver FTP comm. channel everything went fine.
    We now encountered a similar problem with a RFC receiver adapter. We're using it in another scenario HTTP XML -> XI -> RFC to SAP R/3 (4.7).
    For some reason it died (red status in adapter monitor) and it was no more possible to do RFC calls from XI to SAP R/3 (normal RFC adapter, NO proxies).
    In XI message monitor everything seemed to be ok but no message arrived till SAP R/3. Nothing in any queue...
    After deactivating and reactivation the RFC receiver comm. channel it worked again BUT ALL PREVIOUSLY SENT messages seem to be lost.
    Is it really the way it works? Does XI integration engine at runtime NOT catch whether or not a RFC or FTP receiver adapter died, thus is not able to tell somewhere in message monitor that a message could not be delivered at all?
    I'm really confused here but hopefully I simply don't understand some easy principles to take into account...
    Our SAP R/3 is on rel. 4.70 with Web AS 6.20. The XI 3.0 plugin is not installed. Do we need to go with server proxies there and use QOS = best effort?!?
    Thanks for some suggestions.
    Best regards,
    Renaud

    Hi Michal
    Thanks... works great for normal XML based messages!
    Now, what if I wanted to pass binary files from one ftp server via BPM to another ftp server in order to enable the transport acknowledgment?
    The files polled from ftp server using the ftp sender adapter are all in binary format (ARJ). No xml data in there. How should the message format look like in BPM for the receiving step? Or: how to make sure not to loose the binary content when passing through BPMs?
    I need this sort of scenario because of the tansport acknowledgment and because I need to have some sort of message splitting (send the binary file over to a second ftp server and additionally send some kind of info message to SAP R/3 regarding thin binary file).
    BTW: in the MessagingSystem/monitor/monitor.jsp I do not see sender / receiver information. Is this normal? It's quite of a bad thing to look inside each message in order to find out what message I'm having in front of me...
    Thanks a lot for your support and patience!
    Kind regards,
    Renaud

  • Jdbc adapter error on confirmation message in message monitor (rwb)

    I have the scenario iDoc -> PI 7 - > jdbc (AS400 odbc driver).
    When I do INSERT statements, the data is stored in the Database and the RWB message monitoring shows status Successfull.
    However, for every insert, an other message shows up in the message monitoring with reversed Sender and Receiver (so it looks like a confirmation message is trying to find its way back to XI). This message first is is Status "Waiting", and after some time gets in Status "System Error".
    As I am not expecting any responses in my XI configuration (as I have no place to send them to), I want to stop these messages showing up in the Adapter Engine (as there will be many Error Status messages that are of no interest to me).
    How can I stop these messages, or what should I do in XI to process them (and dump them in my receiver determination). I have NO  BPM involved .

    Hi,
    For each open connection a entry is made j2ee stack.So when the it reaches to max and execption is thrown.
    In Jdbc adapter configuration -> advance mode -> Set -> Disconnect from the database after processing each message.
    Should solve the prob
    <b>Cheers,
    *RAJ*
    *REWARD POINTS IF FOUND USEFULL*</b>

  • File Adapter picks up the file but cant see it in MONI/Message Monitoring

    Hi
    I am using FCC in Sender File Adapter and have only one sub structure under Recordset hence I have not used the 'Key Field Name' though ''Key Field Type' by default is 'String(Case-Sensitive)'. Besides the 'fieldNames' heading I have mentioned all the fields of the sub structure in the same order as I have mentioned in the Data Type.
    The problem that I am facing is that even though the file is picked up from ftp successfully still I cant see any traces of it in either MONI or Message Monitoring though
    The error that I receive in the MDT is -
    Success : Entire file content converted to XML format
    Warning : Empty document found. Proceed without sending message
    Success : File "Test.csv" deleted after processing
    and I have data in the file.
    Can u suggest a solution?
    Warm regards,
    Vaibhav

    > Hey
    > >>So I have filled my test excel file with the values
    > A and B in adjacent columns
    > are you picking up some .xls file?if yes,then Content
    > conversion wont work,You have to create adapter
    > module processor and you have to add to your module
    > processor bean to the adapter...Just check the
    > following procedure...
    > https://www.sdn.sap.com/irj/sdn/weblogs?blog=/pub/wlg/
    > 1967
    > Thanx
    > Aamir suhail
    Hi Aamir
    I had a look at the blog and according to that I will need to create a module...the prob with that is in the blog he hasnt provided the full steps for that. Also I had tried this thing earlier of using an excel file and saving it in .csv format and it had worked. I cant figure out what the error is this time
    Have u worked on creating amodule for excel files b4?
    Vaibhav

  • Messages are Holding in message monitoring tool

    Hi All,
    I am facing the problem with messages which are in holding state.
    My scenario is file to proxy. The file content contains of EDI. my scenario is already gone to production last year.
    and its working fine. Used java mappings for validation of EDI file. its running successfully.
    where as in Dev system till october first i used to load the files in FTP inbox folder and messages were processed successfully.
    But from october first week when i load the files in FTP inbox, file has been picking succesfully and can see the logs in sender comm channel  but the i can see that my interface is in holding state in message monitoring tool and its not going to receiver comm channel. I have loaded 5 files and all are in holding state. 
    even i have cancelled first error message and tried to resend the next message swhich is in holding state, but this is not happening.
    i am using EOIO queue.
    when i cancel the error message remaining messages should processed automatically but its not getting processed here.
    sequencing of the interface triggering is
    1. Interface_1
    2. Interface_2
    3. Interface_3
    4. Interface_4
    Here i am stucking up with the first interface itself.Here only first interface is in holding state.
    can any one advise what could be the problem..
    I m on SP 10.
    Thanks,
    Bhaskar

    Hi Abhijit,
    Even after unchecking the checkbox maintain order at runtime, its not working.
    i think there is no disturbed in message processing sequence.
    my first sender interface itself going into hold state.
    i have cancelled the hold message, even after that remaining messages are processing automatically.
    and also i could not fine any messages in SMQ1 and SMQ2.
    I also deresister and registered te queues and activated.
    Kindly advise what would be the problem..
    in production its working fine and development its not working fine.
    Thanks,
    Bhaskar

  • PI 7.1 - Message Monitoring - Adapter Engine (Database Overview)

    Hi Friends,
    In Message Monitoring --> Adapter Engine --> Database (Overview) is not working. It throws the following error message.
    no_connection Exception Message: RemoteException in Method: CentralViewManager: getIProfiles( IApplication, boolean ). Communication-related failure. Message: java.rmi.RemoteException: Service call exception; nested exception is: com.sap.engine.services.webservices.jaxrpc.wsdl2java.ClientProtocolException: An error occured while reading data from the destination sap.com/com.sap.aii.af.service.profile.proxy/com.sap.aii.af.service.statistic.proxy.ProfileProcessor/basicPort_Document. The error was: com.sap.security.core.server.destinations.api.DestinationException An error occurred while reading the destination sap.com/com.sap.aii.af.service.profile.proxy/com.sap.aii.af.service.statistic.proxy.ProfileProcessor/basicPort_Document, type WebService. The error was Internal error during the decryption process...
    But, Adapter Engine --> Database option is working. What could be the problem ?
    Kindly clarify, friends.
    Kind regards,
    Jegathees P.

    Hello friend,
    May be it is related with connection problem check with your basis people .
    Regards,
    Ravi.

Maybe you are looking for

  • Sap instance is not starting

    Hi this is sathyan here i have SAP 4.6c on win2k and recently when i started the server the nessage server is working ok but the dispatcher starts and then stops immediately. and all the work process end not able to find out the problem please help b

  • KDE, aRts, and the recent flac update

    Good morning, I am running kde 3.3.1. No issues. I performed a pacman -Syu recently, and the flac package was updated. At this point, I lost my sound, specifically aRts is not running in KDE. So KDE native apps that use aRts, such as noatun, and the

  • Transparent Table with Invoicing Plan Information

    Hello, I just want to know what transparent table have the Invoicing Plan Information from a Line Item. Regards, Hector

  • How to use Tomcat

    Hello friends I want to use some functions which are in Java Servlet Specification 2.3. I found that I have to use Tomcat for this. Any one who know about it please help, to find where I will get Its setup and required information to run the servlet

  • Hi Experts, the result of a table content in se16n?

    Hi Experts, in the ALV output of se16n, some columns are in green, what does this stand for? thanks. Kind regards Dawson