Adapter not in the monitoring

Hello
I have a problem with sp12. I can not see the adapter in the monitoring. I now some people have the same problem in this forum. I have made all this steps. Then i have the adapter in the monitoring. I have use the  program rsxmb_activate_icf_services.
After i reboot the sap system and the adapters was not in the monitoring. Then i start the program rsxmb_activate_icf_services again, put it is no more working.
Thanks for some help?
Regards Tom

Hallo
Now, it is runnig.
1. First I clean the SLD Content with Note 764176
2. Check sld
3. Then I check the right for the xiafuser
4. Run the the programm RSXMB_ACTIVATE_ICF_SERVICES
5. Reimport the SAP_Basis softwarecoponent (Gudie from Michal)
6. Restart all adapter in the integration configuration.
Thanks for the help to all.
Regards Tom

Similar Messages

  • Sender file adapter not polling the file

    hi all,
    i have configured a filexifile scenario....
    but the file sender adapter is not polling the file at all....
    i dont c any message either in RWB or in SXMB_MONI
    i checked the adapter framework url at <i>http://<ximachine>;<port>/AdapterFramework</i>....and the status for the file adapter is green...
    but the message it gives there is
    <i>Sender Adapter v1014 for Party '', Service 'TASL_FILE_SENDER':
    Configured at 03:07:24 2006-02-02
    Up and running - no message processing until now
      last poll interval started 04:01:24 2006-02-02
      length 60,000 secs</i>
    y is the sender adapter not polling the file..
    i am using NFS as my File System....i gave the source directory as <i>d:/test_dir/</i>
    is this way of specifying the source directory on a windows machine correct...
    thanks
    pavan

    There is probably something wrong with the File Adapter.  You will need to go to the RunTime Workbench >> Component Monitoring >> Display >> Click on the Adapter Engine >> More information will display and click on the button 'Adapter Monitoring' >> A new window will display and click on the arrow next to your adapter engine.  This displays a list of adapters running on your system.  Green light means good; Red, you have a configuration problem.  Look at the error and try and resolve it.

  • Mini dvi to dvi adapter not working with monitor

    arright *** i got a mini dvi to dvi adapter which is connected to my vga monitor through a vga to dvi adapter. The computer recognizes the monitor in display preferences, but the monitor doesn't display anything it just sits in standby mode... any ideas why this isn't working? You'd think if the problem was going from vga-vga to dvi adapter-dvi to mini dvi adapter that it wouldn't even recognize the monitor but it does.
    well that *****, back to best buy to get the other one. Reason i got the dvi one is because i plan on getting a different monitor with dvi soon. But noo dvi adapter wont work with vga adapters.
    Message was edited by: Veiss

    The mini-DVD to DVI adapter doesn't pass through the analog video signals needed for VGA, so won't work with a DVI to VGA adapter. All the control signals are there, so the display is recognized, but there will be no picture.
    They could have used a DVI-D connector on the adapter, instead of DVD-I, so the DVI to VGA adapter wouldn't even plug in, but then it couldn't be used with some non-Apple LCDs, that use DVD-I connecters.

  • Sender File adapter not deleting the source file after reading

    Hi everyone,
    In the sender Communication channel i have choosen the "Delete" option after reading the source file. But it is reading the file, but it is not deleting the file. I have checked the file status. it is with full persmission.
    can anyone give solution to this.
    Thanx
    Bala

    Hi,
    1. set the mode to delete
    2. make sure the file is "deletable"
    3. check xiserver:port/MessagingSystem/monitor log to see what happens with the file
    (chec both audit and log in that link)
    Regards,
    michal
    <a href="/people/michal.krawczyk2/blog/2005/06/28/xipi-faq-frequently-asked-questions"><b>XI / PI FAQ - Frequently Asked Questions</b></a>

  • Sender File adapter not picking the file ABCD.PRN extension file

    Hi
    Am doing File to Abap Proxy scenario. My source will be in text format of fixed length of fileds 7.
    My souce file will be generated by a third party machine with the extension EEE150809.PRN. In my scenario my file adapter should pick the file and update the same in ECC via a Proxy.
    I have configured the Sender File adapter with Message Protocol -  Content Conversion but file adapter is not picking the file. I have checked the Communication channel and status is fine. But the same Communication Channel works for .XML file.
    What are the parameters that I have to consider with the file extension .PRN using File adapter?
    Thanks.
    S.

    Hi Swarna,
    You dont need to worry about the extension when picking the file. You can try using EEE* so that is picks all the files starting with EEE. If you have the fixed name then you can try giving EEE150809.*. Also EEE150809.PRN should not have any issue. Try to see in sender commu ication cahnnel for anyerrors. Probably there might be some network issues or authorisation issues. If you are reading with NFS then ask them to give necessary permissions. If you are reading through FTP check the user id and pwd you are using.
    Regards,
    ---Satish

  • File Adapter Not picking the files

    Hi All,
    We have a process wherein the file adapter picks up the file from a particular location and it processed thereafter. We get the files once every month. We noticed that if the files that are being dazzled are of the same, i.e if the same nomenclature is there for the file that was dazzled the previous month, the adapter does not pick up the file. Only after renaming the file, it picks the file and processed them.
    Any idea why the files that are dazzled with the same name are not being picked up.
    Thanks in Advance...!!

    Hi,
    While configuring file adapter to pick up the files cross verify with file name putting in the directory location against the
    "Includes files with name pattern" "Excludes file with name pattern" file name..
    let say if u kept .*txt if picks the files txt with any name and one more think once after picking up the file from particular location are u enabling (delete file once read) option in configuration(It all depends on ur req)..
    cross check the schema element of the file pattern.

  • File adapter not writing the file correctly

    Hi,
    I am facing an issue where the file created on the destination is not with the correct data. eventhough the payload that was sent out from XI to the adapter is correct.
    Issue was with a mltiple element which was written once eventhough the payload shows multiple existance.
    we had changed the occurance of that element from 1 to unbounded.
    If anyone has any idea do let me know
    Regards
    Nikhil

    I tried to redo the config objects but still the same issue is there. anyone has any idea

  • IGo universal adapter not charging the battery?

    Since yesterday I have realized that my apple adapter for the PowerBook G3 PDQ (aka wallstreet) has died. I plugged in the adapter and the battery icon just stays the way it is. So I plugged in the iGo Juice 70 and yeah the laptop shows the thunderbolt on the battery. Since I know when you use the laptop while charging, it is suppose to charge slowly. In two hours it said the battery is full. I thought the adapter charged it faster. Today I used it in battery mode and it show a full battery. When it was at 92% the laptop fell asleep. I checked the battery tester and it shows that the battery is empty. So I plugged in the same adapter, woke up the laptop, and it showed it was charging from 0% and in one minute it went up to 100%. I also have realized that the battery tester doesn't light up when it is charging. I tried this in OSX 10.2.8 and OS 9.2.2. Is it the adapter, laptop, battery??? Something else???

    Vstream,
    It does not sound like a power adapter issue. Since the adapter will power/run the powerbook, it has sufficient voltage to also charge the battery. Be sure to check if the battery charges in sleep or when turned off. You mentioned that the battery showed 100% charged; you then disconnected the power adapter and let the 'book run on battery; at 94% the 'book shut down. This has nothing to do with the power adapter; you either have a failing battery or a hardware problem in the 'book. Your problems are almost certainly a bad battery with classic symptoms...test LEDs refusing to light and random shutdowns when running on battery.
    A definitive test is swapping batteries with a known-good Wallstreet, but this is usually not an available option.

  • Lightroom not using the Monitor Profile

    I have recently set up a new computer with a new monitor. When I got PS and Lightroom set up on the new system I noticed that when viewing photos in both applications the colors are VERY different compared to how they look viewed online or in another photo viewer from my desktop (windows 8). I also noticed that when I opened PS I got a message saying that the Monitor Profile is "bad" and I could opt out to ignore the profile. When I did ignore it the color looks fine. Blacks are black, gray's are gray, etc . . . Anyway, I am wondering if there is a way I can have Lightroom ignore the profile as well. I have a monitor calibrator and I will try that, but I am wondering if it will do anything only because other applications look fine. Hope someone can shed some light on this!

    First of all, Photoshop and Lightroom are fully color managed applications that will actually use the monitor profile to display the image.Many other applications (viewers/browsers) are not and will just ignore it. So there's a difference right there.
    That said, when you get that message in Photoshop, it means exactly what it says. That profile is bad and should not be used.
    The real solution is to use a calibrator to make a new custom profile for your monitor. Until you get that up and running, use sRGB IEC61966-22.1 as monitor profile. You set this up in Control Panel > Color Management > Devices:

  • My wireless adapter not detecting the Network

    I have a Lenovo 3000 Y100 Laptop. My Wireless network adapter is Intel PRO Wireless 2200B/G. I dont know why but it is not detcting the wireless network in my office network. Do i need some more driver or patch to apply.
    Premanand

    tiki_icwai, Welcome to the forum.
    Try the link below to find solutions to the Intel Pro Wireless 2200b/g adapter connection problems.
    http://www.intel.com/support/wireless/wlan/sb/CS-025332.htm
    Hope this would help you.

  • Windows 10 does not recognize the Monitor as PnP

    Windows 10 has my FT220 HQL touch monitor listed as "generic" and limits the resolution.  Windows 7 recognized the monitor and offred the highest resolution the monitor supports.  The resolution in Windows 10 is very poor and it limits the resolution.  I went through the initial start up procedure as described in the Quick Guide, but it did not help.  The auto Adjust does not improve it either.   I do not see win 10 drivers on the web site.  Is this the problem?  Why doesn't win 10 recognize the monitor?  How do I correct?

    I downloaded the win 8 drivers from the Acer site, but they would not load.  I had a chat with an Acer support person which was useless.  I just revered to windows 7 (easy option in 10), and full function is restored.  I'll check the Acer site from time to time and wait for a win 10 driver.  My Windows 10 upgrade button is still showing, and a copy is reserved.  Thanks for the response.

  • File Sender adapter not reading the first line

    Hi,
    I have a scenario configured from file to jdbc adapter.
    However, I found a problem in my file sender adapter. My file adpater always not picking up the first line from my text even I have set the 'Document Offset' to 0.
    Any Ideas? Thanks.
    Regards,
    Pua

    Hi Latika Sethi,
    My complete input text file is as below, it contains only 2 testing records:-
    H1|DIZ1                          |A0016507    |10000020|09/2007
    H2|ABC0001
    D|P|0001|Gaji Pokok       |   1,000.09
    D|D|0002|Denda              |   1,000.00
    D|P|0003|Elaun               |   1,000.00
    H1|PUA1                        |A0016508    |10000021|09/2007
    H2|ABC0002
    D|P|0001|Gaji Pokok       |   2,744.09
    D|D|0002|Denda              |   2,000.00
    D|P|0003|Elaun               |   2,000.00
    After the message mapping, I found the pipeline existed in sxmb_moni as below:-
    <?xml version="1.0" encoding="utf-8"?>
    <ns:mt_rmp03B_filejdbc_sender xmlns:ns="urn:rmp03:pdrm:ips:jdbcjdbc">
    <PaySlip>
    ..<Header2>
    .... <IC>ABC0001</IC>
    .. </Header2>
    .. <Details>
    .... <Jenis>P</Jenis>
    .... <No>0001</No>
    .... <Deskripsi>Gaji Pokok</Deskripsi>
    .... <Jumlah>1,000.09</Jumlah>
    .. </Details>
    </PaySlip>
    <PaySlip>
    .. <Header1>
    .... <Nama>PUA1</Nama>
    .... <KWSP>A0016508</KWSP>
    .... <NoGaji>10000021</NoGaji>
    .... <Bulan>09/2007</Bulan>
    .. </Header1>
    .. <Header2>
    .... <IC>ABC0002</IC>
    .. </Header2>
    .. <Details>
    .... <Jenis>P</Jenis>
    .... <No>0001</No>
    .... <Deskripsi>Gaji Pokok</Deskripsi>
    .... <Jumlah>2,744.09</Jumlah>
    .. </Details>
    </Payslip>
    There are 2 payslips as for the top payslip node...Header1 tag is missing. It means that during the file sender step....the first line of my record which is :-
    "H1|DIZ1                          |A0016507    |10000020|09/2007"
    is not read into the xi pipeline. Basically this is the problem i faced.
    Has somebody facing the same problem before? Currently I have no choice but moved the First line of the text into Second line and left the first line of the text become null/ empty line. As such both records can be successfully read by the XI.
    However what I wondered is sometimes clients will do insert the records into the first line and this might made some data loss.
    Thanks...

  • File Adapter not picking the file

    Hi Experts,
      I am trying to create a Legacy-XI-R/3 scenario. I am using a file adapter as the sender communication channel and a ABAP proxy at the receiver end. I have given the path of my input file in the legacy system, but the file is not picked up by the adapter. Can any one tell me where I might have gone wrong?

    Hi,
       Just want to add one more suggestion.
    Check the Host name, where the File is kept and try to use the directory path as
    <HostName>\<DirName>.
    Hope this help.
    Aj.

  • JMS adapter not picking the file

    Hello,
    I am working jms to jms scenario on PI7.0 Service Pack13. file is not able to pick up sendar JMS Channel. I am using WebSphereMQ Transport Protocol. JMS drivers are installed.
    I checked all parameters of JMS Adapter. no mistake in parameters. What is the problem. Please suggest as soon as possible.
    Thanks

    Hi,
    Whether the Driver file has been mentioned in Provider XML  file and check  the messages  are in the right sender Queue.
    Check the Port and Protocol are right one.
    Regards
    Agasthuri Doss

  • Unable not find the monitoring object(idoc monitoring ) in BPmon

    Hello Guys,
         As part configuration  of IDOC monitoring in BPmon configuration ,while i am creating monitoring object for IDOC monitoring (solman_workcenter->Business process operations ->setup Business process monitoring  -->selected  the solution --> business scenarios -->
    As mentioned above i could not able to find the IDOC monitoring template  in the droup down list
    Components level on manage system:-
    ST-PI       2008_1_710 SP 08
    ST-A/PI   01Q_731 SP2
    I have done the load monitoring definition by selecting respective local component and clicked on load monitoring definitions 
    Please help me on resolving the issue.
    Regards,
    Pavan

    Hello Calvin van der Walt,
    Please upgrade ST-PI & ST-A/PI component to latest level.I resolved my issue by doing ST-PI & ST-A/PI component upgarde.
    I had raised an OSS message eith SAP on this isssue and SAP has asked us for ST-PI & ST-A/PI component upgarde.
    So please go with ST-PI & ST-A/PI component upgarde it will resolve your issue.
    Regards,
    Pavan

Maybe you are looking for