Adding PCI-7833R to RTsi cable in MAX

I am trying to add my FPGA (PCI-7833R) to a RTSI cable in MAX.  The cable is connected in the chassis, and both the device and the cable appear in MAX.  However, when I right click on the cable and select "Add device to NI-RTSI cable," the FPGA does not appear as an option. What am I missing?
Attachments:
Untitled.png ‏161 KB

Hi PTARlab
Thanks for posting.
It's not possible to add the RTSI card to an R series card using MAX, as this is really configuring DAQmx devices not FPGA ones.
Instead, you can gain access to the RTSI lines directly in a Project Explorer. After you have added your PCI-7833R to a project, right click on the FPGA target and select New...>>FPGA I/O. In the next window, you can select all of the RTSI lines and add them to your project. 
Kind Regards
Chris | Applications Engineer NIUK

Similar Messages

  • RTSI cable configuration with PCIe 1433 card

    Hi All:
    I tried to trigger my line camera with RTSI signal.
    The layout is: trigerr signal  is generated from one PCI card 6259 (Dev2/ctr0). The line camera is connected with one PCIe 1433 card, and the two cards were connected with RTSI cable.
    The problem is that how to register or configure PCIe 1433 with RTSI cable in MAX, it seems I can only configure PCI card within RTSI cable ......
    If it is true, how should I do to rout the trigger signal to the camera, such as "route Dev2/ctr0 to Trigger line 0"?
    Below is printscreen of MAX Configuration. Attached is my VI.
    thanks a lot.
    Bob
    Attachments:
    Triggered with RTSI from DAQ.vi ‏63 KB
    camera configuration.jpg ‏218 KB

    Thanks a lot, the post helped.
    But I am still confused with the details:
    To camera and PCIe 1433 configruaration, as the attached pictures shows: RTSI is configurerd as Camera Control Line as number "2"; the exposure control of camera is defined as "triggered".
    In previous attached VI, you may find that the IMAQ configurer trigger is applied to define trigger  type as "RTSI", trigger number as "2".
    About ttrigger signal from PCI 6259 (Dev2), digital pulse is generated and output terminal is defined as ctr0 ( seems only ctr0 or ctr1 is option).
    So I still do not know how to route signal from "Dev2/ctr0" to "Imag0 CCL 2" in labview.
    By the way, I read  the online example "LL Triggered Ring using DAQmx Pulse Train", http://www.ni.com/example/29476/en/.  Within this VI,  the DAQmx Connect Terminals VI is applied to route the counter's output to a RTSI pin so the signal can be used by the IMAQ device. However Dev2/ctro is not recognized as scour terminal, only other items such as PFI, APFI or RTSI are avaible, and output signal source is also limited with similar things, sounds like just internal connectrion with Dev2.
    thanks a lot.

  • PCI-7833R RTSI Bus

    I'm in the process of integrating a second PCI-7833R into my project (a towable wideband echo repeater for submarine target emulation).
    The first board does the actual echo repeating (acquisition, trigger filtering, and detection, etc.)
    The second board will do optional signal generation and transmit equalization.
    Could I use the RTSI Bus as a data bus between the two boards? The project manager seems to treat them as general purpose IO.
    Where do I find the pinout and function description for the RTSI Bus Connector as this info is not in the PCI-7833R documentation.
    Thanks

    Hi,
    Yes, you can use the RTSI Line. However, you will need to connect the two 7833R board together through the RTSI connector using RTSI cable.
    The user manual for 78XX describes how to access and use the RTSI line on Page 36 (RTSI Trigger Bus). This knowledge base entry also provides the RTSI connector pinout for National Instruments PCI boards.
    Tunde

  • Creation of RTSI cable on remote RT PC

    Hi, I have two PCIe6363 boards on my remote RT PC. And I want to use RTSI cable to synchronize these two boards on one data acquisition task. BUT, I can not create the RTSI cable in the MAX, actually, I even did not find the option of NI-RTSI cable, please see the attached picture. The driver for DAQmx is NI-DAQmx 9.6.2. Could anyone please help me to figure out what is wrong with my system? and is it possible to sync two PCIe boards without the RTSI cable?
    Thanks a lot in advance!

    Hi,
    I am afraid that you cannot achieve this via mstsc. It only refers to the display settings on the host machine. Therefore, you may have to change the display settings on A physically.
    Thanks.
    Jeremy Wu
    TechNet Community Support

  • PCI-7833r low voltage output problem

    Hi.
    I'm currently working with the PCI-7833R along with the SCB-68 box.  I'm using 6 analog output connectors to send DC voltages out from my computer.
    Most connectors are working fine, apart from AO1 which gives me slow reaction times and AO2 which is attenuated so that I get a maximum voltage of 1V instead of 10V.
    I have temporarily switched them and am using AO6 and AO7, but I would very much like to fix this problem so that I don't lose two precious connectors.
    I've checked the SCB-68 box but there doesn't seem to be any additional electrical components on these two circuits, so I believe this has something to do with the configuration of the FPGA on the computer.
    Does anyone have any ideas?
    Thanks,
    Orel.

    Hi, Joe.
    Thank you for your time.
    I measure the voltages out of the cable.  This is done for all outputs AO0-AO7, which is why I don't understand why there are differences.  I don't think it's the cable, because when I switch it from AO1 to AO6, for example, I get the right output.  This happens only for AO1 and AO2.
    Thanks,
    Orel.

  • PCI-6221 fails self-test in MAX but device manager says it's working

    Hi everyone,
    I bought a few PCI-6221 (37-pin) data acquisition cards and have been able to get one to work but 3 others don't work.
    Device Manager sees them and says they work.  MAX sees them and when I run Self Test, they fail with error number
    -50002.  Motherboards in non-working systems are PC Chips M957G and P25G.  OS is Windows XP Pro with SP2.
    I already tried uninstalling SW and the board, reinstalling SW and the
    board...autodetect etc works fine.  I even reformatted
    the HD on one of the computers and reinstalled the OS.  Anyone have any ideas?  Thanks in advance.  Halden
    [email protected]

    Thanks Tom for your suggestion to try NI-DAQ 8.0.  I just saw it today.  Yesterday,
    I was able to isolate 3 PCI-6221-37 boards as defective because they all wouldn't work in another computer while
    one other identical model card did work in that same computer.  I called to arrange to return them to NI and learned
    that for these 3, I needed NI-DAQ 8.0.  The fourth one was okay
    with NI-DAQ 7.5.  Apparently, this was a known problem. 
    I wish NI would have simply notified me that my boards would
    not work with the software sent with them and sent the NIDAQ 8.0 CD as soon as they knew rather than have me
    waste a day of my engineering time trying to figure it all out.  Booo NI.
    One of the boards has worked for almost a day under NIDAQ 8.0.  I was able to make some progress on the
    system I am building.  But then it stopped working.  LabVIEW
    (version 7.0 executable) programs would not open completely
    or would open slowly.  One that accessed the COM port only (no
    data acquisition) did work.  MAX opened very slowly or not at all
    and when I click on
    Devices and Interfaces, the hourglass is up for a long time and finally the + icon goes away indicating that MAX is not
    aware of any devices being present.  The Windows Device Manager says the board is present and working.  Windows
    Task Manager lists LabVIEW Runtime and MAX when only MAX is open and indicates that MAX is Not Responding.
    I shut down the computer, removed the PCI-6221 board, booted it up again, and MAX is the same way.  I uninstalled
    MAX and NI-DAQ LabVIEW 7.0 support and then reinstalled them.
    Now the MAX loading window is up for more than a minute and NIMAX.exe is listed in Task Manager's processes.  After
    the first minute, LabVIEW Runtime appears in the Task Manager's
    Applications list.  After a while longer, the MAX window finally
    opens
    and MAX is listed in the Applications.  I click on the + icon by Devices and Interfaces in MAX and the hourglass appears
    and Windows Task Manager says MAX is Not Responding.  Eventually, the + icon and the hourglass go away and
    the Task Manager lists LabVIEW Runtime and MAX as Running.
    I shut the computer off for several minutes, started it up again, and MAX is still takes a long, long time to open. 
    I haven't put the PCI-6221 card back in because MAX still isn't working.
    What do you suggest I do next?
    Thanks
    Halden

  • In Primavera Risk Analysis, the MIN. ML, MAX columns is for imput the minimum impact, most likely impact , maximum impact duration of a risk or the remaining duration for MIN, ML and adding remaining duration with maximum impact for MAX?

    In Primavera Risk Analysis, the MIN. ML, MAX columns is for imput the minimum impact, most likely impact , maximum impact duration of a risk or the remaining duration for MIN, ML and adding remaining duration with maximum impact for MAX?

    You are welcome. I'm glad you got it back up.
    (1) You say you did the symbolic link. I will assume this is set correctly; it's very important that it is.
    (2) I don't know what you mean by "Been feeding the [email protected] for several weeks now, 700 emails each day at least." After the initial training period, SpamAssassin doesn't learn from mail it has already processed correctly. At this point, you only need to teach SpamAssassin when it is wrong. [email protected] should only be getting spam that is being passed as clean. Likewise, [email protected] should only be getting legitimate mail that is being flagged as junk. You are redirecting mail to both [email protected] and [email protected] ... right? SpamAssassin needs both.
    (3) Next, as I said before, you need to implement those "Frontline spam defense for Mac OS X Server." Once you have that done and issue "postfix reload" you can look at your SMTP log in Server Admin and watch as Postfix blocks one piece of junk mail after another. It's kind of cool.
    (4) Add some SARE rules:
    Visit http://www.rulesemporium.com/rules.htm and download the following rules:
    70sareadult.cf
    70saregenlsubj0.cf
    70sareheader0.cf
    70sarehtml0.cf
    70sareobfu0.cf
    70sareoem.cf
    70sarespoof.cf
    70sarestocks.cf
    70sareunsub.cf
    72sare_redirectpost
    Visit http://www.rulesemporium.com/other-rules.htm and download the following rules:
    backhair.cf
    bogus-virus-warnings.cf
    chickenpox.cf
    weeds.cf
    Copy these rules to /etc/mail/spamassassin/
    Then stop and restart mail services.
    There are other things you can do, and you'll find differing opinions about such things. In general, I think implementing the "Frontline spam defense for Mac OS X Server" and adding the SARE rules will help a lot. Good luck!

  • La tarjeta NI PCI-6023E no me aparece en max

    La NI PCI-6023E no aparece abilitada en MAX y cuando quiero instalar el driver me pide un CD 2 el cual no tengo, uso Windows 7 y cuando bajo el driver de este link solo aparece el CD1
    http://www.ni.com/download/ni-daqmx-7.3/369/en/
    espero me puedan ayudar para lograr instalar con exito el driver
    gracias  
    Solved!
    Go to Solution.

    Hola;
    Primero que nada; tu versión de LabVIEW no está soportada para Windows 7; sino hasta la versión 2009 sp1. Es posible que LabVIEW no funcione como esperas, por lo que te recomendaría actualizar tu versión.
    Windows Version Compatibility with LabVIEW
    La versión más actual que puedes instalar de DAQmx es la 9.3 para LV 8.5 y Windows 7 que puedes descargar aquí.
    Exito

  • Cable Gateway Max accessing account

    HiI can't seem to get to the suggested URL for accessing my new cable gateway max modem.  I want to change the network key etc.Thanks!

    HI Louisa73 I tried http://192.168.0.1/ With success ! Good luck
    R

  • Mac Pro PCI Express Power "Booster Cable"

    hey
    anyone happen to buy that vid card power cable from welovemacs.com??
    http://www.welovemacs.com/9227128.html
    i'm planning to buy a pair.. but i'm not sure if it will fit....
    one end plugs into the motherboard.. the other end goes into the vid card
    but the question is does it fit the Mac Pro pci express power socket?
    and the other end of it does it fit any standard pc vid card? or is it also smaller?
    as i plan to buy this for my Mac Pro so i can power up the 8800 gtx
    thanks!

    "Connecting the range extender to an Ethernet network so that the range extender could act as a wireless access point instead of a range extender."
    Yes, I am essentially using it as an access point for the Mac Pro (attaching a simple ethernet cord in the back, it will automatically get a handshake with the network), and a wireless extender for my P.C. laptop and Power Mac G4.
    If this doesnt work, I'm gonna move my cable modem and wireless router to my office (and attach Mac Pro directly to modem or router).
    I dont want to have to buy a new Apple Router when I have a perfectly good D-link system going. It currently works with my roomates Powerbook and Airport Express Sation (air tunes), as we got it working last night. If all else fails, I wait till the new express card comes out and get it installed at my local store.

  • Controlling PCI-1422 with Labview instead of MAX

    Hello Experts,
    I want your help in one of my problem. I have a camera from Sensors Unlimited which is SU-640 1.7 RT-D and a NI parallel card PCI-1422. I can use and acquire data with MAX from the camera but I want to operate,use and acquire images from the camera using LabView. Is there any way of exporting or using the camera with Labview instead of writing a fresh code in LabView? 
    Does LabView offer any support or reads automatically from PCI-1422 or any possible solution that I get the block diagram code for using this camera in LabView.
    Please let me know, reply.
    Any help or suggestions will be highly appreciated.
    Thanks in advance!
     

    Nitai wrote:
    Thanks but again it requires writing and struggling with coding and experience on  LabView skills.
    Just wondering something easy. I tried one of the example and it worked actually but I am trying to get more ideas or options to make it look better and impressive.
    You want something and easy and doesn't require any effort on your end?    Hire someone who knows how to program in LabVIEW.

  • Cable gateway max C6300 firmware update in bridge mode

    Hi, does anyone know if the gateway max cable modem (netgear C6300) will still get the OTA firmware update if it's in bridge mode?  I've given up waiting for fixes and am going to put my own router and access point in. Thanks

    As long as it has a connection to the internet, I am pretty sure it will get an update.
    You could try live chat maybe they have a better answer
    https://livechat.telstra.com/TCOM:Crowdsupport:Consumer
    Since it's a staggered release some modems won't get updated till July

  • PCI-4472 self calibration error under MAX

    Hi,
    Our PCI-4472 appeared to have offsets on the order of several hundred microvolts, so I tried a self calibration under MAX (version 4.1.0.3001) to try to reduce them. The self calibration gave me the error message:
    "Measurement taken during calibration produced an invalid AI gain calibration constant."
    Does anyone know where I can find troubleshooting information for this issue, or have any suggestions on how to fix it?
    Thanks,
    Ron Norton
    Faculty Research Assistant
    Gravitation Experiment Research Group
    Department of Physics
    University of Maryland
    College Park, MD

    I am posting this for an applications engineer, intended for this to post last in a linear fashion ~
    I have attached screen grabs of the self test and calibration panels.
    When running the "self-test" panels within MAX, all tests pass.
    I performed the tests after hitting "reset" in MAX.
    Current versions of software installed: Labview Full Dev 8.2., and Max 8.5.
    All upgrades have been applied.
    Ai1 is setup to measure a voltage differential of 1-5 VDC based upon a "differential" input
    across a precision resistor. I have setup custom scale, 1V = -40`C 5V = +180`C.
    I have tried setting sample rates of: 3 @3Hz, 10@60Hz, 100 @600Hz, etc...
    As I run the self test, and it's the same when I launch Labview and work within a VI, I see
    the wave output with what looks like a square wave. I have put a scope on the wire pair
    and do see steady voltage levels. Sensor has a current loop supplying external excitation.
    Sensor output passes thru a linearization circuit operating at 60Hz.
    In the 3rd image I captured Ai0 which is similarly setup in "differential" 1-5VDC input to scaled output.
    You can see the graph image captures the trailing signal just like on Ai1 analog channel.
    I have verified from Omega that the sensor is wired correctly supplying current loop,
    and also taken the wires and "twisted" the pairs for less EMI/RFI crosstalk/noise.
    The sensor and it's power supply are brand new purchased directly from Omega.
    I am planning to send this to a local vendor for calibration, SE Labs in Santa Clara, but if it's
    a matter of the boards circuitry being damaged than it needs repair. I started here about
    3 months ago and after asking around found the PCI-6250 DAQmx board was available.
    Problem is I don't know the history, besides the 2 year calibration expiring Nov of 2006.
    The 1 thing I have not tried is moving the PCI to another slot, but FYI I have just this week
    moved the PCI card over to another workstation that exceeds minimum hdw requirements.
    This card was installed in a Pentium III @848MHz workstation with 424MB of ram.
    Facts are the graph output of both channels look exactly the same in either pc.
    The previous user was an engineer, whom may have exceeded voltages/parameters
    on the analog and/or digital inputs. Thank you again for your knowledgeable replies!
    Sincerely,
    Phil Johnson
    Hardware Technician
    http://www.digitalpersona.com/

  • Adding wireless laptop to eMac cable modem

    My eMac 700 mhz is connected to a cable modem via ethernet. I want to add a wireless laptop also using the cable modem so I can use the laptop anywhere, without having to add Airport on the eMac also. How can this be done?

    You can do this with a wireless router - any model sold by your local computer shop will do, and should cost you around $30-60. At home:
    - connect the cable modem to the router's WAN or "internet" port
    - connect the eMac to one of the router's LAN ports
    - your new laptop will of course connect wirelessly
    All this can also be done exactly as I described with an Apple Airport Extreme Base Station (costs $199). For that premium price you get a device that is arguably easier to set up for Mac users, and you get a built in USB port that can be used to share a connected printer between both the eMac and the laptop.

  • How to synchronize two PCI-6602 via RTSI for semi-period counting of four signals?

    Hello,
    I try to measure 4 PWM signals. For that, I created 4 tasks (newest DAQmx), each with semi-period measuring one signal.
    I want to use DMA so I have two 6602 for each two signals.
    The task aquire a finite number of samples.
    This works fine when starting the tasks subsequently.
    Now I want to start the tasks via a trigger on the RTSI bus.
    But I have no idea how to get this done.
    I use the MX drivers for the first time an find it very difficult to get through the help files.
    I looked at many examples but did not find a solution.
    Most of the time my experiments end with an error message saying that the property is not applicable to this task, or s.th.similar.
    Ans sometimes, when there seems to be a trigger defined, the task will not wait for the trigger and time out.
    Is the anybody who can help me out of this?
    Maybe a little sample program?
    I program in CVI.
    Many Thanks
    Michael.

    This topic is discussed here:
    http://forums.ni.com/ni/board/message?board.id=250&message.id=13383&requireLogin=False
    Hope this helps!

Maybe you are looking for

  • A few "technical" iPhone questions

    Believe it or not, I'm not going to complain about the price drop! Instead, I've owned my iPhone for a couple of days now, and have a few burning questions: 1) Does the iPhone have the ability to keep nagging me that I missed a call? 2) Many times, w

  • How can i pass a varible from a page to another

    Hello , if i have 2 pages for example page1.php and page2.php and i have a varible at page1.php "$x=10;" and i want to pass it to page2.php to use it . How ??? bec. i am doing a site and a user enters his username and i want to use that username at m

  • Apple 20" Model A1038 Screen Shake

    I recently purchased the DVI to ADC adapter to connect my Cinema Display monitor to my PC that uses Radeon HD 4850 video card. The monitor displays fine, but ever now and then the picture shakes vertically. I do not know what is causing this shaking

  • ALV USING ABAP OBJECTS

    HI ALL. WHY I AM NOT ABLE TO COLOUR u2018LIFNRu2019 COLUMN USING FIELDCATALOG(FCAT). HERE IS THE SOURCE CODE. PLZ HELP ME OUT. *& Module pool       ZOOPSDEMO                                         * PROGRAM  ZOOPSDEMO                               .

  • Hide navigation area from Shopping Cart window

    Hi All, We are facing a strange issue in Shopping Cart Page.. From the POWL screen when we are clicking on "Display" button it is opening  com.sap.pct.srm.core.iv_shopprof iview in a new window. But all the navigation are still showing in the page. W