Agent Failover and AD Integration in Operations Manager
Hi
I got some queries around SCOM agent failover and AD Integration:
Does the discovery wizard differentiates between domain-joined and workgroup systems in terms of deploying agent on them?
Why do we ever need Active Directory Integration with Operations Manager as described here
http://technet.microsoft.com/en-us/library/hh212922.aspx
- is it required for non-domain joined Windows systems or any other systems? All the other documents I read are saying that Windows agents can failover to other available MS in resource pool if their currently assigned MS fails and fails back automatically
as soon as it comes back online.
Is the automatic failover applicable to agents installed using client push (Discovery Wizard) Or it applies to agents installed manually using MOMAgent.msi?
Also referred to this article
http://blogs.technet.com/b/meamcs/archive/2013/05/10/is-ad-integration-or-manual-scom-agents-required-to-allow-automatic-windows-agent-failover-between-multiple-scom-management-servers.aspx
but doesn’t seems to be having grip on it so far. Request some details on the above points.
Thanks
Taranjeet Singh
zamn
Hi,
For the first question, I don't think we can use discovery wizard to install agent on non-domain joined computers. Please refer to the below links for how to deploy SCOM agent to non-domain computers:
http://blogs.technet.com/b/quenguyen/archive/2011/07/13/monitoring-non-domain-servers-using-scom.aspx
http://blogs.technet.com/b/stefan_stranger/archive/2012/04/17/monitoring-non-domain-members-with-om-2012.aspx
For the second question, as we can read from the below link:
http://blogs.technet.com/b/meamcs/archive/2013/05/10/is-ad-integration-or-manual-scom-agents-required-to-allow-automatic-windows-agent-failover-between-multiple-scom-management-servers.aspx
SCOM windows agents automatic failover does not require AD integration or PowerShell scripting or Configuration Manager or manual agents installation specially for small to medium environment and agents distribution between different SCOM management servers
can be accomplished through push agents wizard, and windows agents failover can be simply verified from event viewer.
Regards,
Yan Li
Regards, Yan Li
Similar Messages
-
Cisco IPT and Microsoft System Centre Operations Manager
Hi All
Does anybody used Cisco IPT with System Centre Operations Manager?
Does System Centre Operations Manager supports Cisco CallManager OS and Hardware for monitoring?
Thanks
VKSHi David,
Thanks for your reply. I have gone through the links which you have mentioned. As per the Overview of Operations Manager 2007 R2 section in What's New & Improved in Operations Manager 2007 R2 document it is clearly mentioned the below points:
Delivers monitoring across Windows, Linux and Unix servers–all through a single console.
Extend end to end monitoring of distributed applications to any workload running on Windows, Unix and Linux platforms.
The Cisco Servers are also Windows and Linux Based.
Thanks & Regards,
Vaijanath -
CallManager 4.2 and 6.0 on Operations Manager
Hi All,
I can add the publisher and 4 Subscribers belonging to the CallManager 4.2 Cluster on Operations Manager 2.0.2. But for some reason when I add the Publisher on CCM 6.01, the Opeations Manager throws the "Unreachable" error. I am pretty sure that I put in the correct credentials. Can anyone please suggest what is going wrong here?Same cluster ID perhaps?
See Section 3.1.5.3 of the Deployment Best Practices Doc.
http://www.cisco.com/en/US/prod/collateral/netmgtsw/ps6491/ps6705/ps6535/ps7121/prod_white_paper0900aecd8067e2e6.pdf
Thanks,
Michael. -
Hello,
We are currently implementing a Devops solution with SCOM 2012 SP1 and TFS 2010 SP1 and we would like to synchronize APM alerts with TFS and the Operational Issue WorkItem. However we are not
able to sync anything.
Here is our environments :
Products :
SCOM
System Center Operations Manager 2012 SP1
French
OS: Windows 2012 SP1 Std x64
French
DB: SCOM SQL Server 2012 SP1 x64
Management Pack
MP Operations Manager TFS Work Item Synchronisation 7.0.9538.0
MP Alert Attachement 7.0.9538.0 (We have also try the version in the VM DEVOPSALL : 7.0.9538.1005)
TFS
Team Foundation Server 2010 SP1
French 10.0.40219.1
OS: Windows 2008 R2 SP1 Std x64
French
DB: TFS SQL Server 2008 x64
TFS 2012 Object Model Installer (We have also try the version 2010)
Here is our configuration :
TFS Platform
This a French platform with a project based on the Process Template SCRUM 1.0 alone in a Team Project collection. The Operational Issue import completed successfully. It’s possible to manipulate
Operational Issue for all of its states from TFS.
SCOM Platform
We followed the documentation at :
http://technet.microsoft.com/en-us/library/jj883936.aspx
to configure SCOM Alert Attachment and Operation Manager Tfs Work Item Synchronization. Everything seems to be ok. All configurations succeed. We did not configure Intellitrace collector.
The problem occurs when we are trying to push an APM alert to TFS. When we assigned an alert to the Engineering nothing is synchronized in TFS. There is no error in the event viewer on the TFS
server. But, on the SCOM server we get 2 exceptions raised by Microsoft.EnterpriseManagement.Modules.Apm.TfsWISync.OMModules. We provide you the log of the SCOM Server in this mail.
Detailed exceptions :
Exception message are in French. In English it could be : OEF expected. The followed elements are not closed : Source, Link.
Microsoft.SystemCenter.TfsWISync.SyncAttachments.Rule
TFS Work Item Synchronisation ServerName
{EC924637-2725-7C94-8F37-013B657F4530}
Microsoft.EnterpriseManagement.Modules.Apm.TfsConnector.OMModules.ReadOpenAlertsModule
System.Xml.XmlException: Fin de fichier inattendue. Les éléments suivants ne sont pas fermés : Source, Link. Ligne 1, position 65537.
à System.Xml.XmlTextReaderImpl.Throw(String res, String arg)
à System.Xml.XmlTextReaderImpl.ParseElementContent()
à System.Xml.XmlReader.ReadString()
à System.Xml.XmlReader.ReadElementString(String name)
à Microsoft.EnterpriseManagement.Modules.Apm.TfsConnector.Common.DataItems.Links.DeserializeInternal(XmlReader reader)
à Microsoft.EnterpriseManagement.Modules.Apm.TfsConnector.Common.DataItems.Links.Deserialize(String mappings)
à Microsoft.EnterpriseManagement.Modules.Apm.TfsConnector.OMModules.ReadOpenAlertsModule.InitializeConfiguration(XmlReader reader)
à Microsoft.EnterpriseManagement.Modules.Apm.TfsConnector.OMModules.ReadOpenAlertsModule..ctor(ModuleHost`1 moduleHost, XmlReader configurationReader, Byte[] previousState)
Microsoft.SystemCenter.TfsWISync.SyncWorkItems.Rule
TFS Work Item Synchronisation ServerName
{EC924637-2725-7C94-8F37-013B657F4530}
Microsoft.EnterpriseManagement.Modules.Apm.TfsConnector.OMModules.ReadAlertsSyncModule
System.Xml.XmlException: Fin de fichier inattendue. Les éléments suivants ne sont pas fermés : Source, Link. Ligne 1, position 65537.
à System.Xml.XmlTextReaderImpl.Throw(String res, String arg)
à System.Xml.XmlTextReaderImpl.ParseElementContent()
à System.Xml.XmlReader.ReadString()
à System.Xml.XmlReader.ReadElementString(String name)
à Microsoft.EnterpriseManagement.Modules.Apm.TfsConnector.Common.DataItems.Links.DeserializeInternal(XmlReader reader)
à Microsoft.EnterpriseManagement.Modules.Apm.TfsConnector.Common.DataItems.Links.Deserialize(String mappings)
à Microsoft.EnterpriseManagement.Modules.Apm.TfsConnector.OMModules.ReadAlertsSyncModule.InitializeConfiguration(XmlReader reader)
à Microsoft.EnterpriseManagement.Modules.Apm.TfsConnector.OMModules.ReadAlertsSyncModule..ctor(ModuleHost`1 moduleHost, XmlReader configurationReader, Byte[] previousState)
According to you, is there a possible incompatibility of the synchronization system with French environments?
Thanks for your help.
Gregory OTT => http://twitter.com/gregory_ott
ALM Engineer at Tekigo => www.tekigo.comHi,
To monitor the complete TFS infrastructure, you need additional monitoring packs that alert you about a wide range of problems with TFS components. When you import the TFS Work Item Synchronization management pack, it is a best practice to
also import and configure these monitoring packs, you can double check these:
Monitoring Integration between Operations Manager and TFS in System Center 2012 SP1
http://technet.microsoft.com/en-us/library/jj899893.aspx
We
are trying to better understand customer views on social support experience, so your participation in this
interview project would be greatly appreciated if you have time.
Thanks for helping make community forums a great place. -
VRealize Operations Management Packs for Lenovo Compute and Lenovo Network Switches
Lenovo Systems Management Community Members:
Blue Medora is currently developing a two new and distinct VMware vRealize Operations Management Packs aimed at Lenovo datacenter technology -- a vROps MP for Lenovo Compute as well as a vROps MP for Lenovo Network Switches. Our target is to release both vROps MPs in the September timeframe. Both of the MPs will support vROps v6+. If vROps integration with Lenovo Compute and/or Lenovo Network Switches is something that is relevant to you, our product management team is very interested in talking to you about what aspects of the Lenovo-based compute and network infrastructure you like to see surfaced in vROps, models of Lenovo servers and network switches your your organization most commonly leverages, as well as any specific troubleshooting / diagnostic use cases you have around Lenovo compute and network.
Please drop us a line at [email protected] if you'd like to participate in a pre-release program for the vROps MPs for Lenovo Compute and Lenovo Network Switches.Sorry for being a bit slow in responding. Adapting the settings for my wired ethernet adapter as rdhw suggested solved the problem. (But since I am not using any wake-on features, I simply opted to turn them off instead.)
Interestingly, I had previously looked at these settings in the BIOS and turned them off there (forgot to mention this), but it appears the Device Manager settings were overriding the BIOS settings.
So, I still find Access Connections to be slow (it will take maybe half a minute or so to figure out what is happening when I switch between wireless and wired connections), and also getting the X200 to go to sleep takes more time than it used to do (it used to go to sleep momentarily when I, say, closed the lid, whereas now it will need to think for 10-15 seconds first), but at least everything works reasonably well now.
Which is nice, and I don't want to break anything that I don't have the time to fix, so I think I will leave it at this for the time being. Thanks so much for the help (and for the prompt reply)! -
How to get performance data out of SCOM and into a 3rd party management tool
Hi
I am creating an integration between a 3rd party management tool and System Center Operations Manager 2012 R2. I need to export performance data from SCOM into our application for both HyperV servers and virtual machines. Our application runs on
linux so I cannot do any .NET programming.
What is the best way to do this? I am aware of using the Usage SPF web service but this will not share performance data for the hyperv servers, just the virtual machines .
thanks in advanceHi,
We can use SQL query to get SCOM data out, but about how to send those data into your application, this should be related with how you develop your application.
Here is an article about Operations Manager integation, hope it helps:
http://social.technet.microsoft.com/wiki/contents/articles/12804.system-center-2012-integration-guide-operations-manager.aspx
Regards,
Yan Li
Regards, Yan Li -
How to get alerts out of SCOM and into a 3rd party management tool
Hi
I am creating an integration between a 3rd party management tool and System Center Operations Manager 2012 R2. I need to export alerts such as Power Off / Power On / Configuration change for both virtual machines and hyperv servers from SCOM
into our application. Our application runs on linux so I cannot do any .NET programming, however I can run Powershell scripts remotely using WinRM.
What is the best way to do this? I am aware of using the powershell cmdlet Get-SCOMAlert but is there any other way that does not involve polling?
thanks in advanceThink of Orchestrator as a "router", that will route information and workflows between SCOM, and [insert 3rd party product here]. Depending on your 3rd party product, there may be an "integration pack" for it that Orchestrator can use for out of the
box tasks.
So what's an integration pack? Well - think of it like a management pack, but for Orchestrator. SCOM does monitoring, but it doesn't know how to monitor something unless you install the relevant management pack. The management pack contains
all the rules/monitors for monitoring whatever it is you wish to monitor.
Well, an integration pack is similar in concept, except it tells Orchestrator how to interface and integrate with whatever it is you're trying to perform tasks with.
For what you want to do, there is a SCOM integration pack. This is a set of tasks that can get alerts and events out of Operations Manager (there are also tasks that can create and close alerts in Operations Manager).
From what I can imagine - you would want to get alerts out of SCOM when they happen (so you would use one of the SCOM orchestrator tasks to "get alert if status = new, and source = myapplication"), and then you can pass that alert to another task - such
as write it to a CSV file or something. You could then have another task that picks up that CSV file, and passes it to your application where it can be captured. Or you could use the CSV to populate variables in a powershell script, and then powershell
that information into your app.
There are many ways you could do this, but I do believe that Orchestrator would be the better option.
http://www.dreamension.net -
Management pack version difference in System Center - Operations Manager 2012 R2 - Help us.
Hi,
I have SC Operation manager 2012 r2 in my environment. It has managed with multiple management servers.
I have import some unsealed MPs through Ops SDK code and by manually using Operation manager console.
Here with i tried to install higher version of MPs and upgrade its version from 1.1.0.0 to 6.0.0.0.
case 1:
After successful installation of some MPs and check Operation manager console, it showing newly upgraded version(6.0.0.0).
Then i have import that MP and checked its version inside it showing 1.1.0.0(older version).
Here the imported MP has 1.1.0.0 version and console showing its version as 6.0.0.0.
Why it showing different versions in imported MP(inside xml) and Operations manager console view?
case 2:
After that i tried to import other MPs using console. But it showing below error;
Verification failed with 1 errors:
Error 1:
Found error in 2|Monitoring.ActiveDirectory_server|6.0.0.0|Monitoring.ActiveDirectory_server|| with message:
Could not load management pack [ID=Monitoring.Base, KeyToken=9e875220a3987e0b, Version=6.0.0.0]. The management pack was not found in the store.
: Version mismatch. The management pack ([Monitoring.Base, 9e875220a3987e0b, 1.1.0.0]) requested from the database was version 6.0.0.0 but the actual version available is 1.1.0.0.
Its happened in multiple management servers scenario. So Is any possibility to happen because of multiple management servers scenario?. There is no issues in this same MPs while i tried in single management server. These same MPs are imported and working
fine in single management server scenario.
Help me to solve these 2 issues!!
Thanks,
satheesh1) At first, you should make sure that the imported MP has correct version. I will open the XML of the imported MP and check its current version e.g.
When you open the xml file of imported MP, the version number is shown as
<Manifest>
<Identity>
<ID>Microsoft.SystemCenter.Visualization.Component.Library.Resources</ID>
<Version>1.0.0.2</Version>
<Identity>
<Name>Resources library</Name>
<References>
<Reference Alias="System">
<ID>System.Library</ID>
<Version>1.0.0.1</Version>
From the above sample, the imported MP version number is 1.0.0.2.
2) I am using operation console to import the management pack and check the version number in operations console whether it is updated to new version 1.0.0.2
3) Using operations console to export the MP which has imported in step 1) and open it to check what is the version number of MP. Make sure that the version is 1.0.0.2
4) If the above procedure provide a prefer match of version number, re-import all problematic MP.
5) At last, you may use the following SQL to check whether the correct version number of MP is stored in DB successful
select version, friendlyname from managementpackview where friendlyname like 'Microsoft.SystemCenter.Visualizatio%'
Roger -
How does failover and load distribution work in Operations Manager resource pools?
Hello everyone,
I have a couple of questions in regard to failover and load distribution in resource pools.
What is the criteria for an x-plat or network device to initiate a failover?
How is load distributed in a resource pool - Is it round-robin, performance based or something completely different?
In case more than two management servers are in the same pool, and a management server becomes unavailable, how is load distributed among the remaining resource pool members?
Any help is appreciated.
Thx,
ClausHi,
Resource Pools are a collection of Health Services working together to manage instances assigned to the pool.
Workflows targeted to the instances are loaded by the Health Service in the Resource Pool that ends up managing that instance.
If one of the Health Services in the Resource pool were to fail, the other Health Services in the pool will pick up the work that the failed member was running.
And I would like to share this article with you. Hope it helps.
http://www.systemcentercentral.com/how-does-the-failover-process-work-in-opsmgr-2012-scom-sysctr/
Niki Han
TechNet Community Support -
VMM Agent Not Monitored By Operations Manager
I am getting this alert
VMM Agent Not Monitored By Operations Manager
I have VMM 2012 sp1 and SCOM 2012 sp1 so please kindly tell me the solution.For VMM Agent Not Monitored By Operations Manager, Please, Send if there is error in event viewer
Also Check below link to help you in Fix your Issue
http://blogs.technet.com/b/operationsmgr/archive/2012/01/23/potential-issues-with-vmm-2012-opsmgr-integration.aspx
For Configuration of Operation Manager to monitor VMM, Refer to below link
http://www.systemcentercentral.com/configuring-pro-integration-between-opsmgr-2012-and-vmm-2012/
Please remember, if you see a post that helped you please click "Vote As Helpful" and if it answered your question, please click "Mark As Answer". -
SCOM 2012 SP1- Getting Event ID 20070 on some agents and Event ID 200000 on management servers
On a significant number of my 2012 SP1 Agents, I am getting the following Event IDs in my OperationsManager event log:
20070
The OpsMgr Connector connected to XXXXXX.domain.net, but the connection was closed immediately after authentication occurred. The most likely
cause of this error is that the agent is not authorized to communicate with the server, or the server has not received configuration.
21006
The OpsMgr Connector could not connect to XXXXXX.domain.net:5723. The error code is 10060L(A connection attempt failed because the connected
party did not properly respond after a period of time, or established connection failed because connected host has failed to respond.).
21015
OpsMgr was unable to set up a communications channel to XXXXXX.domain.net. Communication will resume when XXXXXX.domain.net is available and
communication from this computer is allowed.
On my various 2012 SP1 Management Servers, I am getting the following Event IDs in my OperationsManager event logs:
20000
A device which is not part of this management group has attempted to access this Health Service.
Requesting Device Name: servername.domain.com
Here are my settings and what I have tried:
We have agents assigned by AD-integration, and they are receiving their proper assignment
Agents are manually installed with SCCM 2012
“Automatically approve new manually installed agents” is selected
I have rebuilt the Health Service State folder and rebooted the service on the agent server
I have rebuilt the Health Service State folder on my management server and rebooted it to reset all services
On several agent servers that I am experiencing this issue, they are on the same network as their assigned management server, so there is no firewall issue.Hi,
Here is a KB for your reference.
Troubleshooting gray agent states in System Center Operations Manager
http://support.microsoft.com/kb/2288515
We
are trying to better understand customer views on social support experience, so your participation in this
interview project would be greatly appreciated if you have time.
Thanks for helping make community forums a great place. -
Hi Community,
I submitted this question because I'm a bit stuck with SCOM 2012 R2, I'll try to explain briefly what is happening right now in my environment, we have a DEV SCOM Deployment in which all the roles are installed in a single server, this servers is a
VMware machine running Windows Server 2008R2.
The Initial installation of the SCOM Operations Manager and all the other components was not performed by me but by a co-worker, unfortunately he doesn't remember much about the initial configuration. So i had to pickup where he left things about a year
ago, neither of us are SCOM experts, and we have almost no previous experience with previous versions of this application.
Now the problem that I'm facing is the following, all the DEV Servers are Domain Controllers and one of the indication within the "Guide for System Center Management Pack for Active Directory for Operations Manager 2012" states the following
Configuration
Supported?
Agent-less monitoring
No
After my first review I notice that our servers were being monitor by agent-less mode and given the above statement from the Operations Guide the only way that we could ever get those domain controllers monitor by SCOM would be by installing the agent on
each server, so I read somewhere (Can't remember where) that in order to install the agents in all the servers I should first remove them from the Agent-less node, which I did. Then I tried to use the discovery wizard to get the agent install in all of them
but it didn't matter how many times I try the servers never show up.
I read in a Tech Net Article that you had to modify the security settings so SCOM would let me decide if I wanted to approve it or not.
--> http://technet.microsoft.com/en-us/library/hh212853.aspx
I performed the suggested steps from the article but still the servers were not showing up, not even if I run the Discovery wizard, so I decided to go and perform the installation manually in a couple of servers I was able to install the agent in one of
the Domain Controllers, I configured the agent to use a service account that has Domain Admin rights. An hour after I installed the agent I went back to the Operations Console Manager and I check under Pending Action but the Server was not showing up. So i
went back to the Internet to try to find out if someone else had experience the same problem, and in one website some mentioned that if the servers were not showing up it was probably because they were still register in the SCOM Database, now I have no idea
of how i can check that or How can i remove them from there to have them available again, but what troubles me the most is that even after i installed the agent manually the server were not being recognize.
I went to the Event Viewer and I found one particular event that caught my attention, see below :
Log Name: Operations Manager
Source: Health Service Modules
Date: 6/12/2014 12:48:19 PM
Event ID: 11551
Task Category: None
Level: Error
Keywords: Classic
User: N/A
Computer: MyManagementServer
Description:
Computer verification failure for Machine Name: MyManagementServe is 0x800706BA. The RPC server is unavailable.
Event Xml:
<Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
<System>
<Provider Name="Health Service Modules" />
<EventID Qualifiers="49152">11551</EventID>
<Level>2</Level>
<Task>0</Task>
<Keywords>0x80000000000000</Keywords>
<TimeCreated SystemTime="2014-06-12T16:48:19.000000000Z" />
<EventRecordID>1945680</EventRecordID>
<Channel>Operations Manager</Channel>
<Computer>MyManagementServer</Computer>
<Security />
</System>
<EventData>
<Data>MyManagementServe</Data>
<Data>0x800706BA</Data>
<Data>The RPC server is unavailable.</Data>
</EventData>
</Event>
Not sure if this is related to the problem that I'm facing right now, but , I make sure that the RPC Services were running and also the related dependencies too. There's no Firewall enable in any of the servers and DNS seems to be working properly.
Ports 135 / 5723 are open and listening so since I ran out of ideas, I would like to know if some of the experts in this field could perhaps give me some guidelines.
There's one caveat that I haven't mention yet and that is related to SQL, I checked and my user just has read access to SQL i'm not sure if that could affect this but i think is worth mentioning.
My main goal is to have all the servers showing up in the Operations Manager Console.
So thanks all in advance !
Oscar LoriaSo you can ping and nslookup from your ms to these agents and vice versa right? I wouldn't do a manual install, I would push the agent from the management server. You can uninstall the agent manually, or use cleanmom to get rid of them. Then
do an install from the console. When you initiate the install from the console (management server), should it run into any issues it will dump out an error which will give you an idea of where the problem may be.
From Holmans post on this:
e MOM Server could not execute WMI Query "Select * from Win32_OperatingSystem" on
computer “servername.domain.com”
Operation: Agent Install
Install account: DOMAIN\account
Error Code: 800706BA
Error Description: The RPC server is unavailable.
The MOM Server could not execute WMI Query "(null)” on
computer “servername.domain.com”
Operation: Agent Install
Install account: DOMAIN\account
Error Code: 800706BA
Error Description: The RPC server is unavailable.
8004100A
800706BA
1. Ensure agent push account has local admin rights
2. Firewall is blocking NetBIOS access. If Windows 2008 firewall is enabled, ensure “Remote Administration (RPC)” rule is enabled/allowed. We need port 135 (RPC) and the DCOM port range opened for console push through a firewall.
3. Inspect WMI service, health, and rebuild repository if necessary
4. Firewall is blocking ICMP (Live OneCare)
5. DNS incorrect
http://blogs.technet.com/b/kevinholman/archive/2009/01/27/console-based-agent-deployment-troubleshooting-table.aspx
Regards, Blake Email: mengotto<at>hotmail.com Blog: http://discussitnow.wordpress.com/ If my response was helpful, please mark it as so, if it answered your question, then please also mark it accordingly. Thank you. -
Agent disappeared automatically and it appeared in pending management after 6 months.
We had a server (Windows server 2003 64 bit) which was installed and was working fine. Suddenly it disappeared automatically and it appeared in pending management after 6 months. We noticed it only when it came to pending management that the server disappeared
from Agents managed TAB. When we checked the server and found that SCOM was uninstalled or disappeared or what ever. We re installed SCOM now and now from past 1 week we see that the agent is fine.
We are using SCOM 2007R2 CU4 in our environment.
I want to know the reason for this. Post installation of SCOM after this incident we checked the event logs and found the data for the last working of SCOM in that server and found the below events. I was not able to get that much old data in the SCOM Management
server. But got the data from the Agent.
Screen shot:
===========================
Event id: 21033
103
101
21403
21402
5399
1000
45
Below are the contents of the event log
21033:
========
The Management Group CINSCOM was removed from the Microsoft Operations Manager Agent.
For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp.
=======================================================================
Event id: 103
==========
HealthService (2912) Health Service Store: The database engine stopped the instance (0).
For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp.
======================================================================
Event id:101
=========
HealthService (2912) The database engine stopped.
For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp.
==========================================================================
Event id :21403
============
The process started at 12:22:31 PM was terminated because the HealthService requested the workflow to stop, some data may have been lost.
Command executed: "C:\WINDOWS\system32\cscript.exe" //nologo "C:\Program Files\System Center Operations Manager 2007\Health Service State\Monitoring Host Temporary Files 112\4723\AD_Replication_Partner_Op_Master_Consistency.vbs"
cinmlgc25.e2k.ad.ge.com false
Working Directory: C:\Program Files\System Center Operations Manager 2007\Health Service State\Monitoring Host Temporary Files 112\4723\
One or more workflows were affected by this.
Workflow name: AD_Replication_Partner_Op_Master_Consistency.Monitor
Instance name: CINMLGC25
Instance ID: {E49A1DCD-88C3-5615-102B-E8321298AEFF}
Management group: CINSCOM
For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp.
================================================================================
Event id:21402
=============
Forced to terminate the following process started at 12:22:31 PM because it ran past the configured timeout 120 seconds.
Command executed: "C:\WINDOWS\system32\cscript.exe" //nologo "C:\Program Files\System Center Operations Manager 2007\Health Service State\Monitoring Host Temporary Files 112\4723\AD_Replication_Partner_Op_Master_Consistency.vbs"
cinmlgc25.e2k.ad.ge.com false
Working Directory: C:\Program Files\System Center Operations Manager 2007\Health Service State\Monitoring Host Temporary Files 112\4723\
One or more workflows were affected by this.
Workflow name: AD_Replication_Partner_Op_Master_Consistency.Monitor
Instance name: CINMLGC25
Instance ID: {E49A1DCD-88C3-5615-102B-E8321298AEFF}
Management group: CINSCOM
For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp.
=================================================================================
Event id 5399
==========
A rule has generated 50 alerts in the last 60 seconds. Usually, when a rule generates this many alerts, it is because the rule definition is misconfigured. Please examine the rule for errors. In order to avoid excessive load, this rule will be
temporarily suspended until 2013-10-21T12:32:11.0039243-04:00.
Rule: Unexpected_SAM_Failure_5_Rule
Instance: CINMLGC25
Instance ID: {E49A1DCD-88C3-5615-102B-E8321298AEFF}
Management Group: CINSCOM
For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp.
===================================================================================
Eventid: 1000
==============
AD Replication Partner Op Master Consistency : The script 'AD Replication Partner Op Master Consistency' failed to executethe following LDAP query: '<LDAP://loumlgc02.e2k.ad.ge.com/DC=e2k,DC=ad,DC=ge,DC=com>;(&(objectClass=infrastructureUpdate)(fSMORoleOwner=*));fSMORoleOwner;Subtree'.
The error returned was 'Table does not exist.' (0x80040E37)
For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp.
======================================================================================
Event id:45
============
AD Replication Partner Op Master Consistency : Unable to determine infrastructure Op Master on domain controller 'loumlgc02'.
For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp.
=======================================================================================
Can any one please help...Hi,
Based on my understanding, that you re-installed your SCOM, and now everything works fine. You want to know that why your SCOM run into problem 6 months before, right?
According to the event logs in your agent, we could not tell what happened to your Operation manager. What I can see is that the management group was removed from the agent then. And there are some errors when moniored by the former management group.
I would like to suggest you check out what actions have you do on your former management group 6 months before. Maybe we can check the operation manager logs on your management server.
Regards,
Yan Li
Regards, Yan Li -
HP Operations Manager integration pack 7.1 for SCORCH Error
Hi
I am using the HP Operations Manager integration pack 7.1 for SCORCH this is working well sending messages in both directions from SCOM2012 to HP OM and from HP OM to SCOM with the get message/acknowledge message objects but the monitor message object does
not work at all. No errors are logged and we can see the traffic in a network trace. The monitor message object just never triggers.
has anyone else seen this issue ?
ThanksThe problem that I had was with the HP OM función "Monitor Message". Web service didn´t response Orchestrator.
After all I fond the solution, If you Want the Orchestrator to monitor Messages from HPOM you should
define a filter by message group on the activity "monitor Message";
In this case that's because HPOM has the visibility of the user, configured through the atribute "Message Group".
I hope will be useful.
Regards -
VMM Connection to Configuration Manager and Operations Manager
Hi,
i was wondering how do i connect Virtual Machine Manager to Configuration Manager. do i need to have operations manager installed and up and running? or can i connect it to SCCM directly as it is being the main component.
From my understanding of the VMM is that it is used for provisioning and controlling of Hyper visors (cytrix, Vmeare, etc.).
why do i need to go through the Operation Manger? why can i not connect directly to SCCM?
whats the Advantages of using operations manager instead of using CM?
Thanks.VMM has no direct link to Configuration Manager at all.
VMM has a direct link to Operations Manager, which can be integrated and monitor the entire fabric (compute, networking and storage).
The synergy here is that every thing in VMM, will get exposed for monitoring in SCOM.
Configuration Manager has a different approach - as VMM is responsible for the
datacenter - while Configuration Manager manages the clients and eventually applications within the servers/clients.
-kn
Kristian (Virtualization and some coffee: http://kristiannese.blogspot.com )
Maybe you are looking for
-
Error exporting BI Report to Excel
Hi All, We are experiencing strange error, while exporting to Excel. We have a sales report which extract data for 3 regions US, ASIA, EUROPE. The amount of data for particular month is as follows: No Of Rows File
-
Print output of service entry sheet
Dear users, I have configured message output determination for service entry sheet,partner function for vendor and printer configuration from MN13. However when I am running T Code ML83, and putting a service entry sheet no. the message ' no purchasi
-
Problem refreshing the Tree Component icons
Hello, I'm using the Tree, adding the nodes dinamically, following the example: http://www.netbeans.org/kb/55/vwp-databasetree.html This Tree shows the access permissions from the users, and show a red icon on the itens without permissions and a gree
-
Derive 'company code' and 'currency'??
Hi there, I have <b>company cody, chart of account, and currency</b> in my planning level. <b>How can I derive 'chart of account' & 'currency' from 'company code'</b> if I don't like to 'manually' enter 'chart of account' and 'currency' everytime whe
-
Candidate Data -- E-Recruiting
In Create Internal Applications / External Applications service (Recruiter role) in the Candidate Data group there is title / second title field What is purpose of this field, what values are typically used and where do you make the settings. I check