Hello experts,
I have configured technical monitoring in Japanese language.
In the workcenter, the monitoring screen is displayed in Japanese.
But the alert notification is sent in English like following image.
I want to receive the notification in Japanese language.
Could you please tell me how to correct the notification language?
Best regards,
Takashi Nasu
Hi Takashi,
The automatic emails are generated by the background job
'SAP_ALERT_CALCULATION_ENGINE' which created the alerts. This job is
setup in SM37 to run the program 'ACE_CALCULATION_CONTROLLER' in
English language. Hence the email is in english.
Please change the language in the job step to Japenese.
Kind regards,
Roland
Similar Messages
-
Email alert/notification not working with Exchange/Activesync
Hello, I have an Exchange Active sync setup that is otherwise working just fine. Up until this morning, I had the standard audible and vibrate alert when an email was 'pushed' to the iPhone (when locked). This stopped working. I now have to go into the email app, it seems to then 'check' for emails, and only then I receive an alert. I should mention that I upgraded to 2.1 this morning so this could be related. Is it possible that 'push' is not working properly? All my other 'push' settings are the same, and I deleted my account and re-established it to verify I did not miss anything. Thanks in advance.
I am experiencing the same issue. I logged a support incident with Apple; the tech I spoke to added an Exchange acocunt to his iPhone and had the same problem - no "push". He promised to get back to me tomorrow with hopefully a solution. I will keep you posted.
-
Once an alert notification is sent to me as an email. I see an attachment as 'Notification Detail.html'. When I open this attachment it redirects to wrong server name in the URL and the page displays the following message:
Unable to generate forwarding URL. Exception: oracle.apps.fnd.security.DataVerificationException: Invalid CRC length. 28
What and where the change has to applied to get the correct server name in the attachment URL.The problem got resolved. The following URL was wrong in Notification preferences
HTML Agent was
http://<wrongservername>:<wrongport>/pls/<wrongSid>
I did the following,
Login as Sysadmin in Oracle Application Manager OAM
Navigate To --> Workflow Manager-->Go
Notification Mailer link
Edit Workflow Notification Mailer
Clicked Advanced button
Clicked Next 3 times i.e Message Generation wizard page
There HTML AGENT URL was http://<wrongservername>:<wrongport>/pls/<wrongSid>
I corrected the above HTML Agent value and it worked.
Thanks everybody for the inputs.
One more good news to share. I became the active member in oracle forums today. -
Re: Broadband usage alerts being sent to incorrect...
Steve
Re: Broadband alerts going to wrong email address
I have exactly the problem you described and also had long fruitless discussions with BT. Did you mange to resolve the problem and how?
Many thanks
peterwot
Solved!
Go to Solution.I have the same problem as described in earlier posts ie sudden and unexplained increase in broadband use followed by a £5 charge. On investigation it emerges that alerts had been sent to an email address totally unknown to me and not the primary email as listed in my profile last ten years. Fruitless conversations with Customer Care team who say it cannot be changed although a BT error. When passed to Technical Support for further attempts the line predictably goes dead. Informed - in writing - they do not have an email address I can use!
How can I change the incorrect email address being used by BT for alerts?
Why is my broadband allowance suddenly being exceeded when I never download films, music etc?
Is one of the moderators able to help me please?
Many thanks
peterwot -
Incomplete/Incorrect Alert notifications
Good day all.
We set up application monitoring in our SolMan system. The only problem that we're having is that the alert messages we get are incorrect.
What basically happens is that the message placeholders are not replaced with the message variables in the alerts. If you open slg1 though, you get the full correct message.
E.g I would get a message like 'Unrecognized response from credit. & & & &' instead of 'Unrecognized response from credit. IND_AFFORD_IND = N is invalid for Appl.- 0050761111 for BP - 134900427'
So my question here is whether it would be possible for me to pull the correct alert text straight from slg1log or if there's is any other way of getting the message variables replaced..
Any help on this will be greatly appreciated.
Kindest Regards
Vincent
Edited by: Vinchacho on Aug 29, 2011 3:33 PMHi Lydia
I think there is some confusion here - I don't see the possible answer?
I am showing in the Mirror Monitor Screenshot that there was NO STATE CHANGE to show that the CONNECTION was lost!
Rather it is showing the state change to SYNCHRONIZING
Thanks Howard Diesel
Hi Howard,
Refer to this
article, in the Database Mirroring History dialog box, the possible mirroring states are as follows.
◦Unknown
◦Synchronizing
◦Synchronized
◦Suspended
◦Disconnected
According to the error 1479, it indicates that the Mirrorred instance doesn’t receive any responses to ping for 10 seconds from Principal server. It is caused by network latency. To work around this issue, we can increase the timeout value from default 10 seconds
to higher value via the following T-SQL. For more details, please review this blog:
Adjusting the automatic failover time for SQL Server Database Mirroring.
ALTER DATABASE dbName SET PARTNER TIMEOUT 20
Thanks,
Lydia Zhang -
Anyone having alerts with mixed languages like this?
I'm getting alerts (see screenshot) with mixed languages. Is this a lion bug?
I've reinstalled a clean system and repaired disk and permisions but it's still happening.
Regards,
AdamGo to System Preferences and check which language you have at the top of the list?
-
E-mail Alert Notification Action doesn't work
Don't receive Alert notifications on email.
Attributes-> Actions-> Critical Action send to email.
At occurrence Critical Alert of the notification are not sent on email.
If a host or the agent are not accessible, the notification is sent on my email.
How to solve this problem or where see Actions log.
I use the built in module of sending notificationns email.sh.
Whether it's necessary to adjust on each server "Sendmail" for sending notifications or to adjust "Sendmail" on a server where it's installed SunMC.
Enough in that case it's better to use Halcyon PrimeAlert EventAction????
Any Idea?You're right: if you're using the default out-of-the-box email actions, then you need to make sure sendmail is set up on every system with an Agent.
Quite often production systems are running restricted Solaris installs without sendmail, or are behind a firewall that denies email.. that's when you'd really want EventAction (so you only need sendmail on your SunMC Server).
EventAction really is the way to go for any kind of SunMC notification/integration... ...but I work for Halcyon, so you have to assume I'm a biased vendor :)
Regards,
[email protected]
http://www.HalcyonInc.com -
Alert notification whenver stock is posted to a Sto location
Hi Gurus,
My client has following requiremets:
1 An alert notification to be generated to QC department whenever the stock is posted to the sto loc QCH1(inspection lot number should be updated in the alert)
2 An alert to be generated QC department whenevr there is sales good return.(The sto loc is GRN1)
Please guide me how this is possible.
Do we need to use workflow or some enhancements.
Please give details about how to proceed with the enhancements.
Thanks iin advance
Regards
AnkushHi
I think you did not understand my earlier reply. Whenever GR is made when you tick print and choose individula slip in genral tab the requirement is triggered for a message. Utilize that for notification. It can be sent as mail or idoc which can be received in 3rd party system as well.
In output determination for your inventory message schema you should have your output type. (config in output determination)
Then maintain condition record in MN21 for your output type, transaction/event type WE, Print version is 1, print item also 1, and choose simple mail option, send immediatly option and in communication give receipient. It will work as a simple mail
Regards
Antony -
Final Request for Clarification of Mitigating Alerts & Notifications
Hi
Firstly thank you to Tavi, Frank and Hersh. I really appreciate your speedy responses and it has shone light on this topic for me.
I'd like to summarise to ensure I have clearly understood. The mitigating controls, users, controllers and approvers are maintained in the 'Mitigation' tab.
The alerts are emails and relate to the execution of the defined mitigating controls (reports). If the controls are not executed in defined period an alert will be sent to the monitor to remind them or alert them that this activity is to be performed. The Monitor is the person assigned to run these controls reports in specified period.
The notification logs read from R3 logs and will look specifically for mitigated users. It will check to see if they run a combination of the mitigated transactions e.g. create vendor, raise invoice. If this combination of transactions occur a log will generate with relevant details. My question here is 'are notification logs sent my e mail and who is person to receive them, is it the monitor?' If not, where are they to be found. Is this a resource hungry activity and is it recommended.
Is the Monitor the only role relating to above.
Thanks so much in advance.Dear Grainne,
You are most welcome!!
Well, you are all corect for your understanding and summarizations.
Regarding your question - 'are notification logs sent my e mail and who is person to receive them, is it the monitor?' If not, where are they to be found. Is this a resource hungry activity and is it recommended?"
1. Yes, the notification would be sent to monitor who would be the person to say whether the User ID being Mitigated has done something wrong or is perfect as per the business governance. The answer to whether this this can be a resource hungry activity depends on the number of mitigated users and the resource requirement would be directly proportional to the number of mitigation Controls you have set up, which can be further drilled down to the number of mitigated or conflivting transactions used by the User and the frequesncy of the same.
2. The answer to whether it is recommended or not is YES for sure, or else there is no purpose for setting up risks analysis and monitoring.
Regards,
Hersh. -
How to configure ML Server to send Alert Notifications by mail?
Is it possible to configure Mountain Lion Server to send out Alert notification by e-mail without enabling full Mail services?
I don't want to run the Mail service on the Server. I'm quite happy with my ISP's mail service. Besides, I have a dynamic public IP address, hence no rDNS entry (so I couldn't run Mail if I wanted to). And I don't have the expertise to configure and maintain the Mail service. But I would like to get the Server to send me any important alert notifications by e-mail.
I have access to an authenticated SMTP server I can use to relay the outbound alert notification emails. But I don't know how to coerce the alert service into using it. Is it possible to do so, or does one need the full-blown Mail service to be configured (with both dovecot and postfix running) in order to get Alerts to be e-mailed?
Thanks for any help.@MrHoffman,
Thanks for the pointers and suggestions.
The config for my ISP's SMTP server is correct. I specified the port (:465), and double-checked userid/password. It's the same as used by all our e-mail clients (a half-dozen or so on various Macs, iPhones, iPads, Linux boxes), all of which work fine from my LAN.
As for DNS, it seems OK. (I am indebted to you for the excellent series of articles on servers and networking at http://labs.hoffmanlabs.com/node/1705 )
The changeip command reports:
The names match. There is nothing to change.
dirserv:success = "success"
However, I should point out that I do not have the DNS service enabled on ML Server. I already have a local DNS running on my gateway router. (it's an instance of the dnsmasq process that is part of Tomato firmware). It has local names defined for all the servers and hosts on my LAN, and provides rDNS for them as well.
However, what I haven't done is enabled the Mail service. You've (slightly) misunderstood the core of my plan. My intent is not simply to secure the local mail server against remote access. I don't want either remote or local users from accessing the mail server. I don't want it listening for POP or IMAP connections from anywhere (on my LAN or remotely). I don't want it receiving inbound mail from anywhere. I don't want it relaying outbound mail for any client on my LAN. All I want the ML Server to be able to do is to send me alerts (by e-mail) when it's in need of attention. Other appliances on my LAN (eg. a NetgearReadyNAS) can send me e-mails when they are unhappy, and I hope I can coerce the ML Server to do the same.
I know I don't have the expertise to operate and maintain my own mail server, and I'm quite happy with the mail service provided by my existing network service provider. Plus, I'm behind a cable modem with a dynamic IP address, so I'm unable to establish my own rDNS record (which I understand is required to handle inbound mail).
It looks like the next step is to turn on the Mail service. But I'm sure it's going to be unhappy since there's no MX record set-up. I was hoping there was a way that ML Server could simply send out its own outbound alerts (using my ISP's SMTP relay) without having the incoming part of the mail service active. But perhaps Apple didn't anticipate that sort of configuration. -
Hi,
We are using SAP 3.1. In Polish Language, The meu's and sub menus are populating incorrectly. Meaning.. Its showing combination of "#" sign as this error only with Polish language and other languages is working fine.
for example in screen,
Materia#
Bran#a prsem
Please let me know if you need further information and help me out.
Thanks in Advance
SaravanaHi,
Please post few more details like how this started. Is it because of upgrade (SP/Kernel) etc?
Thanks,
Manoj -
Alert notification configuration for Deadline
We are in SRM7.0. For Sc and PO,I have to send alert when the workitem is not processed for 48 hours. I did the configuration in SPRO. The system is trying to send the alert. Whne I check the log in SLG1, it is giving the error message as 'No alert category found'.
When I check the SOST, I see mails with subject 'Alert could not be delivered. Please check document &OBJECT_ID&'. All are in
error status. The send method used is 'RML'. I could see the message 'Cannot process message, no route from <user1> to <user2>.
In SCOT, there is no node created under RML.
Can anyone help me in configuring this alert notification for deadline?
Thanks,
SivagamiHi
Did you Verify your configuration in IMG > Application Server>Basis Services-->Generic Business Tools --> Alert Management
These configurations are required for you to set up Deadline monitoring
1. IMG activity Define Transaction Types
2. IMG activity Define Events
3. IMG activity Define Alert Categories - In the event schema the alert categories are assigned as Subcategories only to events that are to generate alerts. They determine the recipients and the subscribers ( Subscription) and also the short and long text of the alerts. SRM supplies a predefined alert category for the relevant object type in the classification SRM Alerts and you can copy and modify this.
This is done in Event Control for the Object TYpe and Event Schema Combination in Deadline Monitoring COnfiguration under Process Controlled workflow configuration. Make sure each event which you are scheduling is having a Event Category and Subcategory of the Event. Seems you are missing something here.
For more information, see the Help Portal under
http://help.sap.com/ -> SAP R/3 Enterprise, Release 4.70 -> SAP-NetWeaver Components -> SAP Web Application Server -> Basis-Services / Communication Interface -> Business Workplace and Services -> Alert Management -> Alert Category
4. Then you schedule Background job for generating Deadline Alerts. Job SWWDHEX is schedule for this purpose. This is done in Automatic Workflow Customizing(SWU3) --> Maintain Runtime Environment -->Schedule Background job for Missed Deadlines
See also
Note 1051787 - SRM notifications not displayed in UWL
Regards
Virender Singh -
HTC Trophy Alerts/Notifications
For those that have used the phone, a few questions about various HTC Trophy alerts/notifications--for things like missed calls, voicemails, SMS/MMS messages, emails, etc.: 1. For any of those items mentioned above, is there a way to have an alert/notification that not only appears on a live tile but in some other place (perhaps even where you can read part of a message that was sent and/or see who called for a missed call)? 2. Is it possible to set any of these alerts/notifications to be repeatable? For example, if you have a missed call or a new text message, but you weren't by your phone when you got it, could you set things up so that it alerts you every few minutes or so if you wanted to? 3. There seems to be a notification LED present on the phone, is it used for anything else other than battery charging notifications (perhaps again for something like missed calls, voicemails, messages, etc.)? Is it configurable in any way? Thank you.
Strange, for some reason none of the spacing was retained in my first post and it all just appeared as continuous text.
In any case, now that some people have had the phone for a bit, anyone observed anything in the way of (repeatable) alerts/notifications for missed calls, voicemails, text/picture/video messages, etc. as well as any relationship of those alerts/notifications to the notification LED that should be located essentially within the Verizon logo at the top of the phone? -
I had a .mac account that was converted to mobile me, and then to icloud. Whenever someone sends me an ical invite to my .me address, i do receive an email but not an alert/notification on my iphone. If the invite is sent to .mac address i do receive the alert. In fact, sinceOS5 i dont beleive i am receving any alerts from .me ical. . I have checked all the settings. The only thing that makes sense in in the icloud settings unders account it says @mac.com, instead of me.com. I can not change it, I have tried signing out and signing back in under .me but it switichign account right back .mac. Anyoen else experiencing this? i think this is somethign that apple will need to fix but i dotn have teh slightest how to get them to do it?? any help would be great! thanks!
Yes, there are at least 2 other threads discussing the same problem. This seems to be happening to a lot of people, including me. I have only seen one possible fix (trashing the preference file and starting over), but this seems to be a widespread problem and not one involving personal preferences.
-
Alert Notification Email - Information Broadcasting
Dear Forum members ,
I am wondering to setup an alert notification email for Information Broadcasting, so if the job for any reason was failed then system will send an alert notification email to SAP Administrator person
Is any body can help to solve my question ?
Thanks for any help
Regards
udinpetotHi Peggy,
I got a similar requirement but cant able to find a solution for this. Please help me if you have a solution.
A email notification need to be sent to the recipient email id maintained in the broadcaster setting, if the broadcasting fails due to any particular reason.
I started to write a custom program to determine the broadcasting log, but i was not able to find the link between the broadcaster setting and its log (particularly for the scheduling option)
Please let me know if there is any better solution than the custom program.
Thanks a lot for your help
Thanks.
Suresh Kumar
Maybe you are looking for
-
Table For Header Text Old Value
Hi, Could Anyone helpme in finding the table for Header text of the PO , as We know to find the current PO Header Text,by usinf th FM READ_text but i want to to find the header text for the po before Updated , Thanks in advance Regards Priyanka M Ja
-
Is it possible to use my G4 as an external HD to my Intel G5? If yes how is it done? Do I have to remove everything from the G4 drive? Thanks for any help. Marilyn
-
My messages usage says I have 2.9GB of (saved) Messages. Thing is I have not 1 saved message, I delete them all. How can I clear this usage?
-
Derivation of wrong commitment item in ML81N
Dear all, A material document is created in ML81N with expenses a/c Dr. & provision for expenses a/c Cr & the budget is cosumed with debit of the expenses.& also Cr of this provision for expenses.Because the system defaulting the committment item of
-
Parent & Entity Currency Adjustments
Hi Guys, I have no idea of HFM :) We are receiving extracts from HFM which contains data at different levels (Entity Currency, Entity Currency Total, Entity Curr Adj, Parent Curr, Parent Curr Total, Parent Curr Adj). From these extracts we pick up th