Alphanumeric Number Range For Serial Number
Hi Friends
How can i use alpha-numeric number range for serial numbers.I am using serial number profile For GR Process
Regards
Vivek
Hi,
You may check link
http://help.sap.com/erp2005_ehp_03/helpdata/EN/3c/abc157413911d1893d0000e8323c4f/frameset.htm
Ramesh
Similar Messages
-
Number range for serial Number in production order
Hi all,
I want to use the Serial Number in production Order ... It should be generated automatically ... when i try this system creating the serial number from 1.....i want the number to start from 2000000 , How to configure this number range ....
Please advise me ...
Regards,
kumarDear
Following steps are required in Serial Number Management :
1. OIS2 or Go to path SPRO > Plant Maintenance and Customer Service > Master Data in Plant Maintenance and Customer Service > Technical Objects > Serial Number Management > Define Serial Number Profiles. There enter "2" in Stkck column for your serial profile.
2.SPRO->SAP Customizing Implementation Guide->Plant Maintenance and Customer Service->Master Data in Plant Maintenance and Customer Service->Technical Objects->Equipment->Equipment Categories->Define Number Ranges
3. IQ01 Create Serial Number
4. MM02 You need to add the above created Serial Number Profile in the Material Master ion the work scheduling view .
5. CO02 Assigning the Serial Number through Production Order,
Also Serial Number can be created automatically by clicking on u201CCreate Serial Number Automaticallyu201D , Release the Order
6. MB31 Do the GR for the above created Production Order and Check in MMBE for serial Numbers
Try and check
Regards
JH
Edited by: Jiaul Haque on Nov 22, 2010 7:43 AM -
Define Number Range for Reference Number
Hi all,
I am trying to maintain Different Number ranges for Loans in ESS.
Once i maintain Define Number Range for Reference Number in Loans ESS and trying to raise a new loan from ESS is till see that the ref number is still displayed 0 while raising the New Loan.
No From Number To Number
10
I maintained range for number range number 10.
Pls suggest me on this.
The above scenario works for claims but not for Loans
Regards
VijaySolved my self...!
-
Any FM for create an external number range for equipment number ????
Hi all,
Any FM for create an external number range for equipment number??????
thanks & regards
indu.Hi
you can use below FM to get number range
CALL FUNCTION 'NUMBER_GET_NEXT'
EXPORTING
nr_range_nr = 'Z1'
object = 'ZTEST'
object = 'ZFIREC'
quantity = '1'
subobject = p_compcd
toyear = p_fisc
IMPORTING
number = v_seqno.
thanks & regards,
bhupal. -
External number range for equipment number
Hi All,
How to maintain external number range for equipment number?( t-code IE01)
Thanks in advance,
SoumyenduDear ,
Go to...
spro -
pm/cs -
master data in pm/cs ---technical objects ---equipment -equipment categoriesdefine number ranges
Regards,
Ishwar -
Hi , We are using Park and Post functionality for invoice verification.
The number range (Logistics ) defined for RD (Post invoice ) and RS (Cancel Invoice) is 01.
The Number intervals defined for number range 01 are
Number Year From TO Current number
Range
01 9999 5105600101 5105699999 5105603042
But surprizingly when we do MIR7 (Park document ) , current number gets increased by 10 , instead of single.
For example , earlier the current number here (in spro) was 5105603030. I created a MIR7 document, the number given to me in MIR7 was 5105603029 and system didn't change current number in spro.
I created the another document , the number given to me in MIR7 was 5105603030 and system didn;t change the current number in SPRO this time also.
BUT WHEN I CREATED a another document in MIR7 , number given to me was 5105603031 but current number (in SPRO) was changed to 5105603040.
I am not sure , why it is changing CURRENT number with interval of 10 ??
Need yr help
Regards
Shreyhi,
Please check the custumized settings for MIR7, may be u have given in reverse order and the interval between two documents may be 10. please go through the accounting document number ranges.
Thanks & Regards
Swathi -
Different Number Range for Batch number in MIGO
Hi Techies,
I have a requirement to assign the internal range number to Batch Number as K120101701 for CHARG field in MIGO. Where K1 is the Storage location, 2010 is year, 17 is current date 01 is the serial Number. Next day the number range should be K120101801, 18 is next day's date. How can I achieve this?
Thanks & Regards,
Muralikrishna P
Edited by: muralipsharma on Nov 17, 2010 5:35 PM
Moderator Message: Do not dump your specifications here for others to do your work. Try on your own first.
Edited by: kishan P on Nov 18, 2010 11:31 AMjust check with following code . it will give all badi and user exit in the transaction . in selection screen u have to pass tcode and package
<<copy-paste from http://naveenvishal.wordpress.com/2009/07/05/user-exits-and-badi-list-for-a-t-code/ or some other location>>
Moderator Message: DO NOT copy-paste other people's work without giving them due credit. If you continue this, you user-id will have to be deleted.
Edited by: kishan P on Nov 18, 2010 11:36 AM -
Number Ranges for the Serial Number Profiles
Hi All,
We wanted to trace the Goods movement based on the serial numbers. we could make this possible by attaching the serial number profile with relevant procedure (Stock Chk) to the Material.
Now the issue left out is of Number range and the pop-up for the existing serial numbers for the material. Is it possible to define Number Ranges (Ext. / Int) to the Serial Number profile ? Also, to get a pop-up for the serail numbers of material currently in Stock, which can be issued. Currently, I have to get the detail of sr. No. thru' IQ09 / IQ03.
Pls advise.
Shekhar.Hi,
Yes. In IMG under Plant maintenance -- > Technical objects -->Serial No profile.
Here you can create diff profile with difff procedures.
And mention the properties of each.
There is a material master record for each type in the system. For control purposes, the company wants to know which customer received which collector type, and which serial number(s) of the collector type were supplied to the customer, when the individual solar collectors were delivered.
It is therefore necessary to assign a serial number to the customer delivery in addition to the material number.
A serial number master record is created with the assignment of the serial number. You can maintain data fields specific to the serial number in the master record.
At a later date, it may be necessary to enter equipment master records for materials that have already been serialized and delivered to customers, for example, if the producer of the solar collectors also has to perform maintenance activities for the customers and therefore wants to use all the functions available in the equipment master record for a serialized material.
In order to keep this option open at any time, you must define a number range for serial numbers. The numbers assigned from this number range are not the serial numbers but reserved keys that stand for the combination of material number and serial number and the equipment number that may possibly be assigned.
You can also define one or more serial number profiles.
The serial number profile defines how and under which conditions a serial number is assigned for a material.
Note
A material can only be assigned serial numbers after the required serial number profile has been entered in the material master for a specific plant. -
MIGO -Number range for trans./event type WE in year 2012 does not exist
Hi to all
i got one erro while going do MIGO , error is
Number range for trans./event type WE in yar 2012 does not exist .But i checked in OBA7 for the document type WE for that company code i have already maintain number ranges for the year 2011. but system showing error message is WE in year 2012 does not exist . how it showing .Actually My fiscal year is 2011 . why system asking maintain number ranges WE in year .After that i maintaion number ranges for the fiscal year 2012 . and try to post MIGO but i got the same error .Please help us in this sence
Error Details :
Number range for trans./event type WE in yar 2012 does not exist
Message no. M7562
Diagnosis
The number range for document number assignment has not been maintained in the year 2012 for the transaction/event type WE.
Procedure
Contact your system administrator.
If you are authorized to do so, do you want to check the number ranges for the
u2022 Material documents
u2022 Reservations?
Thanks in Advance
RajeshHi Tej,
Even I am getting the same error
"number range for trans./event type WE in year 2014 does not exist"
I have maintained the below number range in tcode OMBT,
Am I missing anything?? Please help!! -
Number range for trans./event type WA in year 2010 does not exist
Dear Sir,
when i used t-code mb1c to initiate the stock, it occured this error message 'Number range for trans./event type WA in year 2010 does not exist'. i've used t-codes(OBMT,FBN1,OBH2), but it still doesn't work. can you tell me how to solve this problem, please? thanks! the detail error messages as below:
Number range for trans./event type WA in year 2010 does not exist
Message no. M7562
Diagnosis
The number range for document number assignment has not been maintained in the year 2010 for the transaction/event type WA.
Procedure
Contact your system administrator.
If you are authorized to do so, do you want to check the number ranges for the
Material documents
Reservations?Follow the below instruction as specified in note 370236.
Maintain the number range intervals in Transaction OMBT or in Transaction SNUM. For every interval of the previous year, there should exist an interval with a year specification that is larger than or equal to the current year.Then assign the interval to a number range group.
The attached analysis report 'ZNRIVCHECK' carries out the following check:
If the year and the document type are entered, the report checks whether an interval exists for the document type and for the year.
If the year is entered or the year and the number range object are entered, the program checks whether the intervals of the previous years exist for all of the year-dependent objects in the specified year.Check whether intervals are needed for all entries of the results list and whether the interval was assigned to the number range groups.
thanks
G. Lakshmipathi -
External Alphanumeric Number Range for Internal Orders
Hello,
I am trying to create external number range for Internal Order Type. I want to create internal orders which will have internal order number as alphanumeric and some will be in only numbers.
How should be the range look like, so that I have flexibility to enter Internal Order number as whatever format I want i.e. T123, 12MP, 1234, ABCD etc.
Any help will be appreciated.
Thanks.how many do you need?
Just one, that covers all?
a0000000 - zzzzzzzz -
External Alphanumeric Number range for order
Hi ,
My requirement is to create an external number range for one PM order type where
first 8 places from left can be alphanumeric and next 4 places should be numeric only .
like EQ12341H0112
here last numeric characters(in bold) actually will specify month and year in format MMYY (0112 means jan2012) . So I doesn't want system to accept last four characters as 1312 or 0012 also (because month should be in range 01 to 12 only)
How I can achieve the same.What number range i should define for external entry .
Regards
PM
Edited by: PM_SAP87 on Jan 18, 2012 11:41 AMHi,
You will not be able to achieve this specific logic by just defining a number range. What you can do is define an external number range that is alphanumeric and use exit IWO10017 to format and validate user entry.
-Paul -
"Alphanumeric" number ranges for material matser
Hi all,
What are the sequence of steps needed to create "Alphanumeric" number ranges for material matser. Can anyone explain me the steps.
ThanksHi,
To add to what Sridhar has said ....we have got 2 number ranges only...
either internal or extenal.....
Better idea is to have internal only untill or unless it is at all required so.
It all depends on material type....
In internal it is more easy to maintain the ranges....but in case of extenal....lot more precaution is required.
Award if any thing answer you query .
Thanks
Dipak -
Alphanumeric number range for object QMERKRUECK
Hi all
I have raised a question on number range object QMERKRUECK few days back.
Internal number assignment for object QMERKRUECK (numbers are in critical area)
With reference to the same please let me clear, if it is possible to create alpha numeric number range for the same object.
I tried in SNRO but system does not allow for this.Next is , if any userexits are there to achieve this.
I know, this issue is hardly seen in any implementation but if anybody has gone through this and got a proper solution, please share your experience.
Regards
D MohantyHello,
You can define number range for Purchase requistions in OMH7 transaction agaist each number range number and you assign can assign these number range number to your purchase requistion document types in SPRP >> Materials management >> Purchasing >> Purchase requistion >>Define doucment type.
E.g for NB doc type number range number is 20
and in OMH7 number range number 20 has interval from- 2000000000 to 2099999999
same way
for RV doc type number range number is 21
and in OMH7 number range number 21 has interval from- 2100000000 to 2199999999
Regards,
Shailesh -
Model or serial number ranges for buying a used Airport Express?
Hi --
I am interested in buying a few used Airport Expresses. Is there a way to determine which generation or version a given Airport Express belongs to, e.g. by serial number range or model number?
Thanks,
RamonBasically there are only two versions of the AirPort Express: 802.11b/g (Model# A1084 / Part# M9470LL/A) & 802.11n (Model# A1264 / Part# MB321LL/A) Note: The Part#s provided are USA-specific.
Maybe you are looking for
-
My iTunes App Store icon was deleted how do I get it back??
My apps store was deleted along with my camera on my iPad. I am trying to figure out how I can get these back? Normally you down load apps from the App Store but that is deleted so I am unable to download any apps including the camera. Help! Thanks!
-
How to migrate reports from Development QA Production environment
Hello, we have 3 Oracle Discoverer 10.1.2.3 environments and I would like to know what is the correct way to migrate reports from DEV to QA and to PROD. I'm researching about this by a couple of days and didn't find anything handy. The most likely wa
-
I hope his is the right forum for such a discussion. We all know Appleworks Days are numbered. But I, for one wish it wasn't so and would like so see some dialogue on keeping applesorks for another generation. The below was a post in conclusion to a
-
Why can't I download Adobe Premiere?
Hi, I'm a subscriber of Adobe Creative Cloud. Up to now I had (almost) no problems. Today I tried to download Adobe Premiere, which is shown in my list of apps and services on the web. When I click on the download link next to the Premiere Icon the A
-
Can i use ios5 with an iPhone 3
I own an iPhone 3G ( first generation). Can I upgrade the operating system to iOS5? Are they compatible?