Alternative transaction to PFCG
Hi everyone,
I use PFCG to sequence the reports in a role. However since the deployment of the HR module all sensitive transaction have been withdrawn from the support team and this is one of them.
Does anyone know an alternative transaction I can use to but reports in sequence in a role?
Thanks
Gill
Hi Reddy,
Thanks for your note. However isn't this just another way to run transaction PFCG. My problem is that I no longer have access to PFCG either directly or via the Users Account.
I am looking for another way of being able to change the sequence that reports appear in a role. I used to use PFCG but can no longer use that option.
Regards
Gill
Similar Messages
-
C0pying an ESS transaction and customizing ess transaction through PFCG
Hi all,
I need help in copying a ITS ess transaction into a z transaction.
Ex: I am trying to copy PZ03 into ZPZ03. I am not sure whether i can just copy transaction pz03 to zpzo3. Please help me in how to copy a ITS transaction into a new Z transaction and if i wanna do some core modifications how can i do that.
And i think i can hide some buttons...without copying ITS ESS transaction through PFCG. Please help me in this too.
Thanks,
Kranthi.Hi Michael,
Does your problem still persist? Do you have new information regarding the problem?
If the problem is solved: Please mark this thread as answered. Thank you!
Best regards,
Henning. -
Sort list of transactions in PFCG
In transaction PFCG, under the MENU tab:
how can the transaction list under Role Menu be sorted alphabetically?Hi!
Due to the functions of this PFCG transaction, it is not possible here.
For this functionality, use a report in SE38 (or SA38) transaction: S_BCE_68001429
Regards
Tamá -
Non GUI alternative to PB10 Transaction (infpotypes 22 and 24)
Hi guys,
This is a java foreigner in the ABAP land.
I hope I am asking the correct question.
This is the situation:
In order to send a "candidates resume" (curriculum) in to SAP, the ABAP developers made for me a RFC which uses the transaction PB10 (applicant master data).
The RFC when tested in the SAP GUI works fine.
I wrote a java client which calls the RFC, send the parameters and expect the results. This client uses JCO to access SAP.
But, from the java client the RFC works PARTIALLY,
it doesnt fill the education a qualifications (infotypes 22 and 24), and throws error message:
"Exception condition "CNTL_ERROR" raised"
It seem there is an GUI missed, but from JCO I cannot use GUI.
So, I need a non-GUI alternative transaction to the PB10, which writes the data in the infotype 22 and 24.
So, the question here is:
Does somebody knows a non-GUI alternative to the PB10 in order to write the infotypes 22 and 24??
Thanks in advance,
Luisi do have a similar requirement ... from non sap system i am suppose to pass data which saves in table connected to pb10..can you send the RFC developed for your requirement.. it would be helpful for me..
thank you -
Transaction MC46 slow-moving items
Hi,
Is it possible to use this transaction to analyze per storage location ? or is there any alternative transaction for this requirement?
Thanks!Hi,
MC46 can not be used to analyse at the Storage location level as valuation is at the plant level,
You can try to customize a report to analyse slow moving items at the Storage location level,
The tables which can be used for the report MARD/MSEG.... the success of the report depends on how well the functional specifications are defined.
Regards
Merwyn -
Assign Z transaction on SRM portal under check status
Hi ,
I need to create the custom transaction(ZSC04) which is copy of BBPSC04 .
And also assign it under check status with New text .
How I can assign this ZSC04 under check status and will be called from
SRM portal ?
Thanks,
SSHi,
I have assigned Z transaction in PFCG ,it's visible on SRM portal but unable to call the required trnsaction .
Is it require to create ITS service and assign parameters for calling the z transaction on SRM portal ?
Thanks In advance .
Regards,
SS -
Authorization Object for Transaction code XSLT_TOOL
Hi Friends
When i try to use transaction xslt_tool the following error appears "You are not authorized to use transaction xslt_tool".
Can anyone give the Authorization object for transaction xslt_tool,
Regards.
WishvaGive access to the transaction in PFCG.
Then use SU53 to highlight any additional access required. -
User role maintenance (TX PFCG) : S_TCODE cannot be changed
Hello,
We have the following problem in the transaction code PFCG, when trying to edit the authorizations of a role:
the tree "S_TCODE" appears as "Standard" and can only be changed, if you set the authorization fields to "*" (full authorization) ,
please see the printscreen attached.
Is there a way to modify parts of "S_TCODE" ?
Thank you in advance.
Kind regards,
Noémi PocsaiHi Raymond,
Thank you for your reply.
My problem is that, I'd like to change the subtree "Transaction codes" , but it's not possible to edit this... or am I wrong?
Thank you in advance for an answer.
Kind regards,
Noémi -
Hi,
I am new to SAP
I have to grant SM37 to a user
How can I do that ?
Sorry if if it is a basic question
Thanks in advanceHi,
you have to add SM37 in a role which will be assigned to the user. you have to use transaction codes PFCG, SU01.
This is a basic question. you can go through AS ABAP Authorization topic in
http://help.sap.com/saphelp_nw70/helpdata/en/52/6714a9439b11d1896f0000e8322d00/frameset.htm
Lastly, the question related to SAP Security should be posted in the correct forum.
Regards,
Debasis. -
PFCG authorization objects vs SU53 checks
Hi all,
I was thinking I have understood for a long time authorization checks. But no.
So Here's my question.
When I ahd a transaction in PFCG menu, PFCG gets the authorization objects to maintain automatically (from SU24 checks). OK.
When testing the role in ECC : : error. SU53 qays that authorization objects are missing. How the tests are working regarding SU53 and PFCG ?
i.e tcode_de = MDBT in PFCG, PFCG gets M_MTDI_ORG object to maintain => OK
When testing my role, SU53 says that other objects is missing, i.e S_ADMI_FCD. I don't understand because this object is checked with 'NO' in ECC.
Thx.
LaurentHi
> When testing the role in ECC : : error. SU53 qays that authorization objects are missing. How the tests are working regarding SU53 and PFCG ?
The auth checks performed are dependent on lots of things: system config, functional config, master data setup, use of the transaction.
The config in SU24 can't cater for all of those options so SAP gives us the ability to make them more accurate for our particular situations.
> i.e tcode_de = MDBT in PFCG, PFCG gets M_MTDI_ORG object to maintain => OK
>
> When testing my role, SU53 says that other objects is missing, i.e S_ADMI_FCD. I don't understand because this object is checked with 'NO' in ECC.
You can't deactivate a check on an S_ or P_ auth object. These auths are fundamental methods of protecting the SAP application (S_) and personal data (P_)
As David says, the SU53 only shows the last auth failure and there is often lots of spurious stuff reported that isn't required to allow the transaction to process. In this respect ST01 is more useful as it (usually) shows you all the auth checks being evaluated so you can more easily focus on the important ones. -
Hi Everybody,
When the client is performing cycle counting process, they need to know how many times a material has been counted within the counting category (A, B or C) the material has associated.
Is there any way to obtain this info? Right now, they are using LX22 tx but it doesn´t have info enough.
Please let me know if there is any alternative transaction to LX22 which can give more information.
Regards,
Manish.Hi Avinash,
For ecatts check development class/package SECATT_DDIC and transaction SECATT.
For general text transaction is SO10 and tables are STXH and STXL.
For Object Naviagtor SE80 you can change development class.
For function groups check ENLFDIR table.
All transaction codes are stored in TSTC and TSTCT tables
Thanks
Lakshman -
Hi Friends,
I was face some Interview.
Please send answers to the questions?
How many data Fields and key fields we can create in DSO?
You can overwrite key fields or Data Fields?
Which up date we use in Delta queue extraction( v1 or v2 or v3)
Which message we get when transported request is failed?
what is the Structural difference between Infoucbe and DSO
Data Loading is taking huge time when we extract data from source system to BI system/ how to solve?(Before it took 3-4 Hours now data loading takes 4 days)What is the difference between Display Attribute and
Navigational Attribute? How to make display attribute and navigational
attribute?
How to load flat file data?
How to load Hierarchy file data?
What is HACR?
How to maintain HACR?
If any issue in HACR then how to resolve the issue?
What is Baby Cube?
Why we are creating Aggregates?
What is the use of Aggregates?
Is there
any particular field on that we can create Aggregates or we can maintain
Aggregate on any field?
What is
the different DSO available? And what is the difference between those DSO?
What is
replacement path?
What are
the extractor types?
• Application Specific
o BW Content FI, HR, CO, SAP CRM, LO Cockpit
o Customer-Generated Extractors
LIS, FI-SL, CO-PA
• Cross Application (Generic Extractors)
o DB View, InfoSet, Function Module
2. What are the steps involved in LO Extraction?
• The steps are:
o RSA5 Select the DataSources
o LBWE Maintain DataSources and Activate Extract Structures
o LBWG Delete Setup Tables
o 0LI*BW Setup tables
o RSA3 Check extraction and the data in Setup tables
o LBWQ Check the extraction queue
o LBWF Log for LO Extract Structures
o RSA7 BW Delta
Queue Monitor
3. How to create a connection with LIS InfoStructures?
• LBW0 Connecting LIS InfoStructures to BW
4. What is the difference between ODS and InfoCube and MultiProvider?
• ODS: Provides granular data, allows overwrite and data is in transparent
tables, ideal for drilldown and RRI.
• CUBE: Follows the star schema, we can only append data, ideal for primary
reporting.
• MultiProvider: Does not have physical data. It allows to access data from
different InfoProviders (Cube, ODS, InfoObject). It is also preferred for
reporting.
5. What are Start routines, Transfer routines and Update routines?
• Start Routines: The start routine is run for each DataPackage after the data
has been written to the PSA and before the transfer rules have been executed.
It allows complex computations for a key figure or a characteristic. It has no
return value. Its purpose is to execute preliminary calculations and to store
them in global DataStructures. This structure or table can be accessed in the
other routines. The entire DataPackage in the transfer structure format is used
as a parameter for the routine.
• Transfer / Update Routines: They are defined at the InfoObject level. It is
like the Start Routine. It is independent of the DataSource. We can use this to
define Global Data and Global Checks.
6. What is the difference between start routine and update routine, when, how
and why are they called?
• Start routine can be used to access InfoPackage while update routines are
used while updating the Data Targets.
7. What is the table that is used in start routines?
• Always the table structure will be the structure of an ODS or InfoCube. For
example if it is an ODS then active table structure will be the table.
8. Explain how you used Start routines in your project?
• Start routines are used for mass processing of records. In start routine all
the records of DataPackage is available for processing. So we can process all
these records together in start routine. In one of scenario, we wanted to apply
size % to the forecast data. For example if material M1 is forecasted to say
100 in May. Then after applying size %(Small 20%, Medium 40%, Large 20%, Extra
Large 20%), we wanted to have 4 records against one single record that is
coming in the info package. This is achieved in start routine.
9. What are Return Tables?
• When we want to return multiple records, instead of single value, we use the
return table in the Update Routine. Example: If we have total telephone expense
for a Cost Center, using a return table we can get
expense per employee.
10. How do start routine and return table synchronize with each other?
• Return table is used to return the Value following the execution of start
routine
11. What is the difference
between V1, V2 and V3 updates?
• V1 Update: It is a Synchronous update. Here the Statistics update is carried
out at the same time as the document update (in the application
tables).
• V2 Update: It is an Asynchronous update. Statistics update and the Document
update take place as different tasks.
o V1 & V2 don't need scheduling.
• Serialized V3 Update: The V3 collective update must be scheduled as a job
(via LBWE). Here, document data is collected in the order it was created and
transferred into the BW as a batch job. The transfer sequence may not be the
same as the order in which the data was created in all scenarios. V3 update
only processes the update data that is successfully processed with the V2
update.
12. What is compression?
• It is a process used to delete the Request IDs and this saves space.
13. What is Rollup?
• This is used to load new DataPackages (requests) into the InfoCube
aggregates. If we have not performed a rollup then the new InfoCube data will
not be available while reporting on the aggregate.
14. What is table partitioning and what are the benefits of partitioning in an
InfoCube?
• It is the method of dividing a table which would enable a quick reference.
SAP uses fact file partitioning to improve performance. We can partition only
at 0CALMONTH or 0FISCPER. Table partitioning helps to run the report faster as
data is stored in the relevant partitions. Also table maintenance becomes
easier. Oracle,
Informix, IBM DB2/390 supports table partitioning while SAP DB, Microsoft SQL
Server, IBM DB2/400 do not support table portioning.
15. How many extra partitions are created and why?
• Two partitions are created for date before the begin date and after the end
date.
16. What are the options available in transfer rule?
• InfoObject
• Constant
• Routine
• Formula
17. How would you optimize the dimensions?
• We should define as many dimensions as possible and we have to take care that
no single dimension crosses more than 20% of the fact table size.
18. What are Conversion Routines for units and currencies in the update rule?
• Using this option we can write ABAP
code for Units / Currencies conversion. If we enable this flag then unit of Key
Figure appears in the ABAP code as an additional parameter. For example, we can
convert units in Pounds to Kilos.
19. Can an InfoObject be an InfoProvider, how and why?
• Yes, when we want to report on Characteristics or Master Data. We have to
right click on the InfoArea and select "Insert characteristic as data
target". For example, we can make 0CUSTOMER as an InfoProvider and report
on it.
20. What is Open Hub Service?
• The Open Hub Service enables us to distribute data from an SAP BW system into
external Data Marts, analytical applications, and other applications. We can
ensure controlled distribution using several systems. The central object for
exporting data is the InfoSpoke. We can define the source and the target object
for the data. BW becomes a hub of an enterprise data warehouse.
The distribution of data becomes clear through central monitoring from the
distribution status in the BW system.
21. How do you transform Open
Hub Data?
• Using BADI we can transform Open Hub Data according to the destination
requirement.
22. What is ODS?
• Operational DataSource is used for detailed storage of data. We can overwrite
data in the ODS. The data is stored in transparent tables.
23. What are BW Statistics and what is its use?
• They are group of Business Content InfoCubes which are used to measure
performance for Query and Load Monitoring. It also shows the usage of
aggregates, OLAP and Warehouse management
http://www.ittestpapers.com/articles/713/3/SAP-BW-Interview-Questions---Part-A/Page3.html
Communication Structure and Transfer
rules
• Create and InfoPackage
• Load Data
25. What are the delta options available when you load from flat file?
• The 3 options for Delta Management with Flat Files:
o Full Upload
o New Status for Changed records (ODS Object only)
o Additive Delta (ODS Object & InfoCube)
Q) Under which menu path is the Test Workbench to be found, including in
earlier Releases?
The menu path is: Tools - ABAP Workbench - Test - Test Workbench.
Q) I want to delete a BEx query that is in Production system through request. Is
anyone aware about it?
A) Have you tried the RSZDELETE transaction?
Q) Errors while monitoring process chains.
A) During data loading. Apart from them, in process chains you add so many
process types, for example after loading data into Info Cube, you rollup data
into aggregates, now this rolling up of data into aggregates is a process type
which you keep after the process type for loading data into Cube. This rolling
up into aggregates might fail.
Another one is after you load data into ODS, you activate ODS data (another
process type) this might also fail.
Q) In Monitor----- Details (Header/Status/Details) à Under Processing (data
packet): Everything OK à Context menu of Data Package 1 (1 Records): Everything
OK ---- Simulate update. (Here we can debug update rules or transfer rules.)
SM50 à Program/Mode à Program à Debugging & debug this work process.
Q) PSA Cleansing.
A) You know how to edit PSA. I don't think you can delete single records. You
have to delete entire PSA data for a request.
Q) Can we make a datasource to support delta.
A) If this is a custom (user-defined) datasource you can make the datasource
delta enabled. While creating datasource from RSO2, after entering datasource
name and pressing create, in the next screen there is one button at the top,
which says generic delta. If you want more details about this there is a
chapter in Extraction book, it's in last pages u find out.
Generic delta services: -
Supports delta extraction for generic extractors according to:
Time stamp
Calendar day
Numeric pointer, such as document number & counter
Only one of these attributes can be set as a delta attribute.
Delta extraction is supported for all generic extractors, such as tables/views,
SAP Query and function modules
The delta queue (RSA7) allows you to monitor the current status of the delta
attribute
Q) Workbooks, as a general rule, should be transported with the
role.
Here are a couple of scenarios:
1. If both the workbook and its role have been previously transported, then the
role does not need to be part of the transport.
2. If the role exists in both dev and the target system but the workbook has
never been transported, and then you have a choice of transporting the role
(recommended) or just the workbook. If only the workbook is transported, then
an additional step will have to be taken after import: Locate the WorkbookID
via Table RSRWBINDEXT (in Dev and verify the same exists in the target system)
and proceed to manually add it to the role in the target system via Transaction
Code PFCG -- ALWAYS use control c/control v copy/paste for manually adding!
3. If the role does not exist in the target system you should transport both
the role and workbook. Keep in mind that a workbook is an object unto itself
and has no dependencies on other objects. Thus, you do not receive an error
message from the transport of 'just a workbook' -- even though it may not be
visible, it will exist (verified via Table RSRWBINDEXT).
Overall, as a general rule, you should transport roles with workbooks.
Q) How much time does it take to extract 1 million (10 lackhs) of records into
an infocube?
A. This depends, if you have complex coding in update rules it will take longer
time, or else it will take less than 30 minutes.
Q) What are the five ASAP Methodologies?
A: Project plan, Business Blue print, Realization, Final preparation & Go-Live - support.
1. Project Preparation: In this phase, decision makers define clear project
objectives and an efficient decision making process ( i.e. Discussions with the
client, like what are his needs and requirements etc.). Project managers
will be involved in this phase (I guess).
A Project Charter is issued and an implementation strategy is outlined in this
phase.
2. Business Blueprint: It is a detailed documentation of your company's
requirements. (i.e. what are the objects we need to develop are modified
depending on the client's requirements).
3. Realization: In this only, the implementation of the project takes place (development
of objects etc) and we are involved in the project from here only.
4. Final Preparation: Final preparation before going live i.e. testing,
conducting pre-go-live, end user training etc.
End user training is given that is in the client site you train them how to
work with the new environment, as they are new to the technology.
5. Go-Live & support: The project has gone live and it is into production.
The Project team will be supporting the end users.
Q) What is landscape of R/3 & what is landscape of BW. Landscape of R/3 not
sure.
Then Landscape of b/w: u have the development system, testing system, production system
Development system: All the implementation part is done in this sys. (I.e.,
Analysis of objects developing, modification etc) and from here the objects are
transported to the testing system, but before transporting an initial test
known as Unit testing
(testing of objects) is done in the development sys.
Testing/Quality system: quality check is done in this system and integration
testing is done.
Production system: All the extraction part takes place in this sys.
Q) How do you measure the size of infocube?
A: In no of records.
Q). Difference between infocube and ODS?
A: Infocube is structured as star schema (extended) where a fact table is
surrounded by different dim table that are linked with DIM'ids. And the data
wise, you will have aggregated data in the cubes. No overwrite functionality
ODS is a flat structure (flat table) with no star schema concept and which will
have granular data (detailed level). Overwrite functionality.
Flat file
datasources does not support 0recordmode in extraction.
x before, -after, n new, a add, d delete, r reverse
Q) Difference between display attributes and navigational attributes?
A: Display attribute is one, which is used only for display purpose in the
report. Where as navigational attribute is used for drilling down in the
report. We don't need to maintain Navigational attribute in the cube as a
characteristic (that is the advantage) to drill down.
Q. SOME DATA IS UPLOADED TWICE INTO INFOCUBE. HOW TO CORRECT IT?
A: But how is it possible? If you load it manually twice, then you can delete
it by requestID.
Q. CAN U ADD A NEW FIELD AT THE ODS LEVEL?
Sure you can. ODS is nothing but a table.
Q. CAN NUMBER OF DATASOURCES HAVE ONE INFOSOURCE?
A) Yes of course. For example, for loading text and hierarchies we use
different data sources but the same InfoSource.
Q. BRIEF THE DATAFLOW IN BW.
A) Data flows from transactional system to analytical system (BW). DataSources
on the transactional system needs to be replicated on BW side and attached to
infosource and update rules respectively.
Q. CURRENCY CONVERSIONS CAN BE WRITTEN IN UPDATE RULES. WHY NOT IN TRANSFER
RULES?
Q) WHAT IS PROCEDURE TO UPDATE DATA INTO DATA TARGETS?
FULL and DELTA.
Q) AS WE USE Sbwnn, sbiw1, sbiw2 for delta update in LIS THEN
WHAT IS THE PROCEDURE IN LO-COCKPIT?
No LIS in LO cockpit. We will have datasources and can be maintained (append
fields). Refer white paper
on LO-Cockpit extractions.
Q) Why we delete the setup tables (LBWG) & fill them (OLI*BW)?
A) Initially we don't delete the setup tables but when we do change in extract
structure we go for it. We r changing the extract structure right, that means
there are some newly added fields in that which r not before. So to get the
required data ( i.e.; the data which is required is taken and to avoid
redundancy) we delete n then fill the setup tables.
To refresh the statistical data.
The extraction set up reads the dataset that you want to process such as,
customers orders with the tables like VBAK, VBAP) & fills the relevant communication
structure with the data. The data is stored in cluster
tables from where it is read when the initialization is run. It is important
that during initialization phase, no one generates or modifies application
data, at least until the tables can be set up.
Q) SIGNIFICANCE of ODS?
It holds granular data (detailed level).
Q) WHERE THE PSA DATA IS STORED?
In PSA table.
Q) WHAT IS DATA SIZE?
The volume of data one data target holds (in no. of records)
Q) Different types of INFOCUBES.
Basic, Virtual (remote, sap remote and multi)
Virtual Cube is used for example, if you consider railways reservation all the
information has to be updated online. For designing the Virtual cube you have
to write the function module that is linking to table, Virtual cube it is like
a the structure, when ever the table is updated the virtual cube will fetch the
data from table and display report Online... FYI.. you will get the information
: https://www.sdn.sap.com/sdn
/index.sdn and search for Designing Virtual Cube and you will get
a good material designing the Function Module
Q) INFOSET QUERY.
Can be made of ODS's and Characteristic InfoObjects with masterdata.
Q) IF THERE ARE 2 DATASOURCES HOW MANY TRANSFER STRUCTURES ARE THERE.
In R/3 or in BW? 2 in R/3 and 2 in BW
Q) ROUTINES?
Exist in the InfoObject, transfer routines, update routines and start routine
Q) BRIEF SOME STRUCTURES USED IN BEX.
Rows and Columns, you can create structures.
Q) WHAT ARE THE DIFFERENT VARIABLES USED IN BEX?
Different Variable's are Texts, Formulas, Hierarchies, Hierarchy nodes &
Characteristic values.
Variable Types are
Manual entry /default value
Replacement path
SAP exit
Customer exit
Authorization
Q) HOW MANY LEVELS YOU CAN GO IN REPORTING?
You can drill down to any level by using Navigational attributes and jump
targets.
Q) WHAT ARE INDEXES?
Indexes are data base indexes, which help in retrieving data fastly.
Q) DIFFERENCE BETWEEN 2.1 AND 3.X VERSIONS.
Help! Refer documentation
Q) IS IT NESSESARY TO INITIALIZE EACH TIME THE DELTA UPDATE IS USED?
No.
Q) WHAT IS THE SIGNIFICANCE OF KPI'S?
KPI's indicate the performance of a company. These are key figures
Q) AFTER THE DATA EXTRACTION
WHAT IS THE IMAGE POSITION.
After image (correct me if I am wrong)
Q) REPORTING AND RESTRICTIONS.
Help! Refer documentation.
Q) TOOLS USED FOR PERFORMANCE TUNING.
ST22, Number ranges, delete indexes before load. Etc
Q) PROCESS CHAINS: IF U has USED IT THEN HOW WILL U SCHEDULING DATA DAILY.
There should be some tool to run the job daily (SM37 jobs)
Q) AUTHORIZATIONS.
Profile generator
Q) WEB REPORTING.
What are you expecting??
Q) CAN CHARECTERSTIC INFOOBJECT CAN BE INFOPROVIDER.
Of course
Q) PROCEDURES OF REPORTING ON MULTICUBES
Refer help. What are you expecting? MultiCube works on Union condition
Q) EXPLAIN TRANPSORTATION OF OBJECTS?
Dev---àQ and Dev-------àP
Q) What types of partitioning are there for BW?
There are two Partitioning Performance aspects for BW (Cube & PSA)
Query Data Retrieval
Performance Improvement:
Partitioning by (say) Date Range improves data retrieval by making best use of
database [data range] execution plans and indexes (of say Oracle database engine).
B) Transactional Load Partitioning Improvement:
Partitioning based on expected load volumes and data element sizes. Improves
data loading into PSA and Cubes by infopackages (Eg. without timeouts).
Q) How can I compare data in R/3 with data in a BW Cube after the daily delta
loads? Are there any standard procedures for checking them or matching the
number of records?
A) You can go to R/3 TCode RSA3 and run the extractor. It will give you the
number of records extracted. Then go to BW Monitor to check the number of
records in the PSA and check to see if it is the same & also in the monitor
header tab.
A) RSA3 is a simple extractor checker program that allows you to rule out
extracts problems in R/3. It is simple to use, but only really tells you if the
extractor works. Since records that get updated into Cubes/ODS structures are
controlled by Update Rules, you will not be able to determine what is in the
Cube compared to what is in the R/3 environment. You will need to compare
records on a 1:1 basis against records in R/3 transactions for the functional
area in question. I would recommend enlisting the help of the end user community
to assist since they presumably know the data.
To use RSA3, go to it and enter the extractor ex: 2LIS_02_HDR. Click execute
and you will see the record count, you can also go to display that data. You
are not modifying anything so what you do in RSA3 has no effect on data quality
afterwards. However, it will not tell you how many records should be expected
in BW for a given load. You have that information in the monitor RSMO during
and after data loads. From RSMO for a given load you can determine how many
records were passed through the transfer rules from R/3, how many targets were
updated, and how many records passed through the Update Rules. It also gives
you error messages from the PSA.
Q) Types of Transfer Rules?
A) Field to Field mapping, Constant, Variable & routine.
Q) Types of Update Rules?
A) (Check box), Return table
Q) Transfer Routine?
A) Routines, which we write in, transfer rules.
Q) Update Routine?
A) Routines, which we write in Update rules
Q) What is the difference between writing a routine in transfer rules and
writing a routine in update rules?
A) If you are using the same InfoSource to update data in more than one data
target its better u write in transfer rules because u can assign one InfoSource
to more than one data target & and what ever logic u write in update rules
it is specific to particular one data target.
Q) Routine with Return Table.
A) Update rules generally only have one return value. However, you can create a
routine in the tab strip key figure calculation, by choosing checkbox Return
table. The corresponding key figure routine then no longer has a return value,
but a return table. You can then generate as many key figure values, as you
like from one data record.
Q) Start routines?
A) Start routines u can write in both updates rules and transfer rules, suppose
you want to restrict (delete) some records based on conditions before getting
loaded into data targets, then you can specify this in update rules-start
routine.
Ex: - Delete Data_Package ani ante it will delete a record based on the
condition
Q) X & Y Tables?
X-table = A table to link material SIDs with SIDs for time-independent
navigation attributes.
Y-table = A table to link material SIDs with SIDS for time-dependent navigation
attributes.
There are four types of sid tables
X time independent navigational attributes sid tables
Y time dependent navigational attributes sid tables
H hierarchy sid tables
I hierarchy structure sid tables
Q) Filters & Restricted Key figures (real time example)
Restricted KF's u can have for an SD cube: billed quantity, billing value, no:
of billing documents as RKF's.
Q) Line-Item Dimension (give me an real time example)
Line-Item Dimension: Invoice no: or Doc no: is a real time example
Q) What does the number in the 'Total' column in Transaction RSA7 mean?
A) The 'Total' column displays the number of LUWs that were written in the
delta queue and that have not yet been confirmed. The number includes the LUWs
of the last delta request (for repetition of a delta request) and the LUWs for
the next delta request. A LUW only disappears from the RSA7 display when it has
been transferred to the BW System and a new delta request has been received
from the BW System.
Q) How to know in which table (SAP BW) contains Technical Name / Description
and creation data of a particular Reports. Reports that are created using BEx
Analyzer.
A) There is no such table in BW if you want to know such details while you are
opening a particular query press properties button you will come to know all
the details that you wanted.
You will find your information about technical names and description about
queries in the following tables. Directory of all reports (Table RSRREPDIR) and
Directory of the reporting component elements (Table RSZELTDIR) for workbooks
and the connections to queries check Where- used list for reports in workbooks
(Table RSRWORKBOOK) Titles of Excel Workbooks in InfoCatalog (Table
RSRWBINDEXT)
Q) What is a LUW in the delta queue?
A) A LUW from the point of view of the delta queue can be an individual
document, a group of documents from a collective run or a whole data packet of
an application
extractor.
Q) Why does the number in the 'Total' column in the overview screen of
Transaction RSA7 differ from the number of data records that is displayed when
you call the detail view?
A) The number on the overview screen corresponds to the total of LUWs (see also
first question) that were written to the qRFC queue and that have not yet been
confirmed. The detail screen displays the records contained in the LUWs. Both,
the records belonging to the previous delta request and the records that do not
meet the selection conditions of the preceding delta init requests are filtered
out. Thus, only the records that are ready for the next delta request are
displayed on the detail screen. In the detail screen of Transaction RSA7, a
possibly existing customer exit is not taken into account.
Q) Why does Transaction RSA7 still display LUWs on the overview screen after
successful delta loading?
A) Only when a new delta has been requested does the source system learn that
the previous delta was successfully loaded to the BW System. Then, the LUWs of
the previous delta may be confirmed (and also deleted). In the meantime, the
LUWs must be kept for a possible delta request repetition. In particular, the
number on the overview screen does not change when the first delta was loaded
to the BW System.
Q) Why are selections not taken into account when the delta queue is filled?
A) Filtering according to selections takes place when the system reads from the
delta queue. This is necessary for reasons of performance.
Q) Why is there a DataSource with '0' records in RSA7 if delta exists and has
also been loaded successfully?
It is most likely that this is a DataSource that does not send delta data to
the BW System via the delta queue but directly via the extractor (delta for
master data using ALE change pointers). Such a DataSource should not be
displayed in RSA7. This error is corrected with BW 2.0B Support Package 11.
Q) Do the entries in table ROIDOCPRMS have an impact on the performance of the
loading procedure from the delta queue?
A) The impact is limited. If performance problems are related to the loading
process from the delta queue, then refer to the application-specific notes (for
example in the CO-PA area, in the logistics cockpit area and so on).
Caution: As of Plug In 2000.2 patch 3 the entries in table ROIDOCPRMS are as
effective for the delta queue as for a full update. Please note, however, that
LUWs are not split during data loading for consistency reasons. This means that
when very large LUWs are written to the DeltaQueue, the actual package size may
differ considerably from the MAXSIZE and MAXLINES parameters.
Q) Why does it take so long to display the data in the delta queue (for example
approximately 2 hours)?
A) With Plug In 2001.1 the display was changed: the user has the option of
defining the amount of data to be displayed, to restrict it, to selectively
choose the number of a data record, to make a distinction between the 'actual'
delta data and the data intended for repetition and so on.
Q) What is the purpose of function 'Delete data and meta data in a queue' in
RSA7? What exactly is deleted?
A) You should act with extreme caution when you use the deletion function in
the delta queue. It is comparable to deleting an InitDelta in the BW System and
should preferably be executed there. You do not only delete all data of this
DataSource for the affected BW System, but also lose the entire information
concerning the delta initialization. Then you can only request new deltas after
another delta initialization.
When you delete the data, the LUWs kept in the qRFC queue for the corresponding
target system are confirmed. Physical deletion only takes place in the qRFC
outbound queue if there are no more references to the LUWs.
The deletion function is for example intended for a case where the BW System,
from which the delta initialization was originally executed, no longer exists
or can no longer be accessed.
Q) Why does it take so long to delete from the delta queue (for example half a
day)?
A) Import PlugIn 2000.2 patch 3. With this patch the performance during
deletion is considerably improved.
Q) Why is the delta queue not updated when you start the V3 update in the
logistics cockpit area?
A) It is most likely that a delta initialization had not yet run or that the
delta initialization was not successful. A successful delta initialization (the
corresponding request must have QM status 'green' in the BW System) is a
prerequisite for the application data being written in the delta queue.
Q) What is the relationship between RSA7 and the qRFC monitor (Transaction
SMQ1)?
A) The qRFC monitor basically displays the same data as RSA7. The internal
queue name must be used for selection on the initial screen of the qRFC
monitor. This is made up of the prefix 'BW, the client and the short name of
the DataSource. For DataSources whose name are 19 characters long or shorter,
the short name corresponds to the name of the DataSource. For DataSources whose
name is longer than 19 characters (for delta-capable DataSources only possible
as of PlugIn 2001.1) the short name is assigned in table ROOSSHORTN.
In the qRFC monitor you cannot distinguish between repeatable and new LUWs.
Moreover, the data of a LUW is displayed in an unstructured manner there.
Q) Why are the data in the delta queue although the V3 update was not started?
A) Data was posted in background. Then, the records are updated directly in the
delta queue (RSA7). This happens in particular during automatic goods receipt
posting (MRRS). There is no duplicate transfer of records to the BW system. See
Note 417189.
Q) Why does button 'Repeatable' on the RSA7 data details screen not only show
data loaded into BW during the last delta but also data that were newly added,
i.e. 'pure' delta records?
A) Was programmed in a way that the request in repeat mode fetches both
actually repeatable (old) data and new data from the source system.
Q) I loaded several delta inits with various selections. For which one is the
delta loaded?
A) For delta, all selections made via delta inits are summed up. This means, a
delta for the 'total' of all delta initializations is loaded.
Q) How many selections for delta inits are possible in the system?
A) With simple selections (intervals without complicated join conditions or
single values), you can make up to about 100 delta inits. It should not be
more.
With complicated selection conditions, it should be only up to 10-20 delta
inits.
Reason: With many selection conditions that are joined in a complicated way,
too many 'where' lines are generated in the generated ABAP
source code that may exceed the memory limit.
Q) I intend to copy the source system, i.e. make a client copy. What will
happen with may delta? Should I initialize again after that?
A) Before you copy a source client or source system, make sure that your deltas
have been fetched from the DeltaQueue into BW and that no delta is pending.
After the client copy, an inconsistency might occur between BW delta tables and
the OLTP delta tables as described in Note 405943. After the client copy, Table
ROOSPRMSC will probably be empty in the OLTP since this table is
client-independent. After the system copy, the table will contain the entries
with the old logical system name that are no longer useful for further delta
loading from the new logical system. The delta must be initialized in any case
since delta depends on both the BW system and the source system. Even if no
dump 'MESSAGE_TYPE_X' occurs in BW when editing or creating an InfoPackage, you
should expect that the delta have to be initialized after the copy.
Q) Is it allowed in Transaction SMQ1 to use the functions for manual control of
processes?
A) Use SMQ1 as an instrument for diagnosis and control only. Make changes to BW
queues only after informing the BW Support or only if this is explicitly
requested in a note for component 'BC-BW' or 'BW-WHM-SAPI'.
Q) Despite of the delta request being started after completion of the
collective run (V3 update), it does not contain all documents. Only another
delta request loads the missing documents into BW. What is the cause for this
"splitting"?
A) The collective run submits the open V2 documents for processing to the task
handler, which processes them in one or several parallel update processes in an
asynchronous way. For this reason, plan a sufficiently large "safety time
window" between the end of the collective run in the source system and the
start of the delta request in BW. An alternative solution where this problem
does not occur is described in Note 505700.
Q) Despite my deleting the delta init, LUWs are still written into the
DeltaQueue?
A) In general, delta initializations and deletions of delta inits should always
be carried out at a time when no posting takes place. Otherwise, buffer
problems may occur: If a user started the internal mode at a time when the
delta initialization was still active, he/she posts data into the queue even
though the initialization had been deleted in the meantime. This is the case in
your system.
Q) In SMQ1 (qRFC Monitor) I have status 'NOSEND'. In the table TRFCQOUT, some
entries have the status 'READY', others 'RECORDED'. ARFCSSTATE is 'READ'. What
do these statuses mean? Which values in the field 'Status' mean what and which
values are correct and which are alarming? Are the statuses BW-specific or
generally valid in qRFC?
A) Table TRFCQOUT and ARFCSSTATE: Status READ means that the record was read
once either in a delta request or in a repetition of the delta request.
However, this does not mean that the record has successfully reached the BW
yet. The status READY in the TRFCQOUT and RECORDED in the ARFCSSTATE means that
the record has been written into the DeltaQueue and will be loaded into the BW
with the next delta request or a repetition of a delta. In any case only the
statuses READ, READY and RECORDED in both tables are considered to be valid.
The status EXECUTED in TRFCQOUT can occur temporarily. It is set before
starting a DeltaExtraction for all records with status READ present at that
time. The records with status EXECUTED are usually deleted from the queue in
packages within a delta request directly after setting the status before
extracting a new delta. If you see such records, it means that either a process
which is confirming and deleting records which have been loaded into the BW is
successfully running at the moment, or, if the records remain in the table for
a longer period of time with status EXECUTED, it is likely that there are
problems with deleting the records which have already been successfully been
loaded into the BW. In this state, no more deltas are loaded into the BW. Every
other status is an indicator for an error or an inconsistency. NOSEND in SMQ1
means nothing (see note 378903).
The value 'U' in field 'NOSEND' of table TRFCQOUT is discomforting.
Q) The extract structure was changed when the DeltaQueue was empty. Afterwards
new delta records were written to the DeltaQueue. When loading the delta into
the PSA, it shows that some fields were moved. The same result occurs when the
contents of the DeltaQueue are listed via the detail display. Why are the data
displayed differently? What can be done?
Make sure that the change of the extract structure is also reflected in the
database and that all servers are synchronized. We recommend to reset the
buffers using Transaction $SYNC. If the extract structure change is not
communicated synchronously to the server where delta records are being created,
the records are written with the old structure until the new structure has been
generated. This may have disastrous consequences for the delta.
When the problem occurs, the delta needs to be re-initialized.
Q) How and where can I control whether a repeat delta is requested?
A) Via the status of the last delta in the BW Request Monitor. If the request
is RED, the next load will be of type 'Repeat'. If you need to repeat the last
load for certain reasons, set the request in the monitor to red manually. For
the contents of the repeat see Question 14. Delta requests set to red despite
of data being already updated lead to duplicate records in a subsequent repeat,
if they have not been deleted from the data targets concerned before.
Q) As of PI 2003.1, the Logistic Cockpit offers various types of update
methods. Which update method is recommended in logistics? According to which
criteria should the decision be made? How can I choose an update method in
logistics?
See the recommendation in Note 505700.
Q) Are there particular recommendations regarding the data volume the
DeltaQueue may grow to without facing the danger of a read failure due to
memory problems?
A) There is no strict limit (except for the restricted number range of the
24-digit QCOUNT counter in the LUW management table - which is of no practical
importance, however - or the restrictions regarding the volume and number of
records in a database table).
When estimating "smooth" limits, both the number of LUWs is important
and the average data volume per LUW. As a rule, we recommend to bundle data
(usually documents) already when writing to the DeltaQueue to keep number of
LUWs small (partly this can be set in the applications, e.g. in the Logistics
Cockpit). The data volume of a single LUW should not be considerably larger
than 10% of the memory available to the work process for data extraction
(in a 32-bit architecture with a memory volume of about 1GByte per work
process, 100 Mbytes per LUW should not be exceeded). That limit is of rather
small practical importance as well since a comparable limit already applies
when writing to the DeltaQueue. If the limit is observed, correct reading is
guaranteed in most cases.
If the number of LUWs cannot be reduced by bundling application transactions,
you should at least make sure that the data are fetched from all connected BWs
as quickly as possible. But for other, BW-specific, reasons, the frequency
should not be higher than one DeltaRequest per hour.
To avoid memory problems, a program-internal limit ensures that never more than
1 million LUWs are read and fetched from the database per DeltaRequest. If this
limit is reached within a request, the DeltaQueue must be emptied by several
successive DeltaRequests. We recommend, however, to try not to reach that limit
but trigger the fetching of data from the connected BWs already when the number
of LUWs reaches a 5-digit value.
Q) I would like to display the date the data was uploaded on the
report. Usually, we load the transactional data nightly. Is there any easy way
to include this information on the report for users? So that they know the
validity of the report.
A) If I understand your requirement correctly, you want to display the date on
which data was loaded into the data target from which the report is being
executed. If it is so, configure your workbook to display the text elements in
the report. This displays the relevance of data field, which is the date on which
the data load has taken place.
Q) Can we filter the fields at Transfer Structure?
Q) Can we load data directly into infoobject with out extraction is it
possible.
Yes. We can copy from other infoobject if it is same. We load data from PSA if
it is already in PSA.
Q) HOW MANY DAYS CAN WE KEEP THE DATA IN PSA, IF WE R SHEDULED DAILY, WEEKLY
AND MONTHLY.
a) We can set the time.
Q) HOW CAN U GET THE DATA FROM CLIENT IF U R WORKING ON OFFSHORE PROJECTS.
THROUGH WHICH NETWORK.
a) VPN…………….Virtual
Private Network, VPN is nothing but one sort of network
where we can connect to the client systems sitting in offshore through RAS
(Remote access server).
Q) HOW CAN U ANALIZE THE PROJECT AT FIRST?
Prepare Project Plan and Environment
Define Project Management
Standards and
Procedures
Define Implementation Standards and Procedures
Testing & Go-live + supporting.
Q) THERE is one ODS AND 4 INFOCUBES. WE SEND DATA AT TIME TO ALL CUBES IF ONE
CUBE GOT LOCK ERROR. HOW CAN U RECTIFY THE ERROR?
Go to TCode sm66 then see which one is locked select that pid from there and
goto sm12
TCode then unlock it this is happened when lock errors are occurred when u
scheduled.
Q) Can anybody tell me how to add a navigational attribute in the BEx report in
the rows?
A) Expand dimension under left side panel (that is infocube panel) select than
navigational attributes drag and drop under rows panel.
Q) IF ANY TRASACTION CODE LIKE SMPT OR STMT.
In current systems (BW 3.0B and R/3 4.6B) these Tcodes don't exist!
Q) WHAT IS TRANSACTIONAL CUBE?
A) Transactional InfoCubes differ from standard InfoCubes in that the former
have an improved write access performance level. Standard InfoCubes are
technically optimized for read-only access and for a comparatively small number
of simultaneous accesses. Instead, the transactional InfoCube was developed to
meet the demands of SAP Strategic Enterprise Management (SEM), meaning that,
data is written to the InfoCube (possibly by several users at the same time)
and re-read as soon as possible. Standard Basic cubes are not suitable for
this.
Q) Is there any way to delete cube contents within update rules from an ODS
data source? The reason for this would be to delete (or zero out) a cube record
in an "Open Order" cube if the open order quantity was 0.
I've tried using the 0recordmode but that doesn't work. Also, would it
be easier to write a program that would be run after the load and delete
the records with a zero open qty?
A) START routine for update rules u can write ABAP code.
A) Yap, you can do it. Create a start routine in Update rule.
It is not "Deleting cube contents with update rules" It is only
possible to avoid that some content is updated into the InfoCube using the
start routine. Loop at all the records and delete the record that has the
condition. "If the open order quantity was 0" You have to think also
in before and after images in case of a delta upload. In that case you may
delete the change record and keep the old and after the change the wrong
information.
Q) I am not able to access a node in hierarchy directly using variables for
reports. When I am using Tcode RSZV it is giving a message that it doesn't
exist in BW 3.0 and it is embedded in BEx. Can any one tell me the other
options to get the same functionality in BEx?
A) Tcode RSZV is used in the earlier version of 3.0B only. From 3.0B onwards,
it's possible in the Query Designer (BEx) itself. Just right click on the
InfoObject for which you want to use as variables and precede further selecting
variable type and proce -
Useful Interview Questions and Answere
Hi All
Some of the Real time question.
Q) Under which menu path is the Test Workbench to be found, including in earlier Releases?
The menu path is: Tools - ABAP Workbench - Test - Test Workbench.
Q) I want to delete a BEx query that is in Production system through request. Is anyone aware about it?
A) Have you tried the RSZDELETE transaction?
Q) Errors while monitoring process chains.
A) During data loading. Apart from them, in process chains you add so many process types, for example after loading data into Info Cube, you rollup data into aggregates, now this rolling up of data into aggregates is a process type which you keep after the process type for loading data into Cube. This rolling up into aggregates might fail.
Another one is after you load data into ODS, you activate ODS data (another process type) this might also fail.
Q) In Monitor----- Details (Header/Status/Details) à Under Processing (data packet): Everything OK à Context menu of Data Package 1 (1 Records): Everything OK -
Simulate update. (Here we can debug update rules or transfer rules.)
SM50 à Program/Mode à Program à Debugging & debug this work process.
Q) PSA Cleansing.
A) You know how to edit PSA. I don't think you can delete single records. You have to delete entire PSA data for a request.
Q) Can we make a datasource to support delta.
A) If this is a custom (user-defined) datasource you can make the datasource delta enabled. While creating datasource from RSO2, after entering datasource name and pressing create, in the next screen there is one button at the top, which says generic delta. If you want more details about this there is a chapter in Extraction book, it's in last pages u find out.
Generic delta services: -
Supports delta extraction for generic extractors according to:
Time stamp
Calendar day
Numeric pointer, such as document number & counter
Only one of these attributes can be set as a delta attribute.
Delta extraction is supported for all generic extractors, such as tables/views, SAP Query and function modules
The delta queue (RSA7) allows you to monitor the current status of the delta attribute
Q) Workbooks, as a general rule, should be transported with the role.
Here are a couple of scenarios:
1. If both the workbook and its role have been previously transported, then the role does not need to be part of the transport.
2. If the role exists in both dev and the target system but the workbook has never been transported, and then you have a choice of transporting the role (recommended) or just the workbook. If only the workbook is transported, then an additional step will have to be taken after import: Locate the WorkbookID via Table RSRWBINDEXT (in Dev and verify the same exists in the target system) and proceed to manually add it to the role in the target system via Transaction Code PFCG -- ALWAYS use control c/control v copy/paste for manually adding!
3. If the role does not exist in the target system you should transport both the role and workbook. Keep in mind that a workbook is an object unto itself and has no dependencies on other objects. Thus, you do not receive an error message from the transport of 'just a workbook' -- even though it may not be visible, it will exist (verified via Table RSRWBINDEXT).
Overall, as a general rule, you should transport roles with workbooks.
Q) How much time does it take to extract 1 million (10 lackhs) of records into an infocube?
A. This depends, if you have complex coding in update rules it will take longer time, or else it will take less than 30 minutes.
Q) What are the five ASAP Methodologies?
A: Project plan, Business Blue print, Realization, Final preparation & Go-Live - support.
1. Project Preparation: In this phase, decision makers define clear project objectives and an efficient decision making process (i.e. Discussions with the client, like what are his needs and requirements etc.). Project managers will be involved in this phase (I guess).
A Project Charter is issued and an implementation strategy is outlined in this phase.
2. Business Blueprint: It is a detailed documentation of your company's requirements. (i.e. what are the objects we need to develop are modified depending on the client's requirements).
3. Realization: In this only, the implementation of the project takes place (development of objects etc) and we are involved in the project from here only.
4. Final Preparation: Final preparation before going live i.e. testing, conducting pre-go-live, end user training etc.
End user training is given that is in the client site you train them how to work with the new environment, as they are new to the technology.
5. Go-Live & support: The project has gone live and it is into production. The Project team will be supporting the end users.
Q) What is landscape of R/3 & what is landscape of BW. Landscape of R/3 not sure.
Then Landscape of b/w: u have the development system, testing system, production system
Development system: All the implementation part is done in this sys. (I.e., Analysis of objects developing, modification etc) and from here the objects are transported to the testing system, but before transporting an initial test known as Unit testing (testing of objects) is done in the development sys.
Testing/Quality system: quality check is done in this system and integration testing is done.
Production system: All the extraction part takes place in this sys.
Q) How do you measure the size of infocube?
A: In no of records.
Q). Difference between infocube and ODS?
A: Infocube is structured as star schema (extended) where a fact table is surrounded by different dim table that are linked with DIM'ids. And the data wise, you will have aggregated data in the cubes. No overwrite functionality
ODS is a flat structure (flat table) with no star schema concept and which will have granular data (detailed level). Overwrite functionality.
Flat file datasources does not support 0recordmode in extraction.
x before, -after, n new, a add, d delete, r reverse
Q) Difference between display attributes and navigational attributes?
A: Display attribute is one, which is used only for display purpose in the report. Where as navigational attribute is used for drilling down in the report. We don't need to maintain Navigational attribute in the cube as a characteristic (that is the advantage) to drill down.
Q. SOME DATA IS UPLOADED TWICE INTO INFOCUBE. HOW TO CORRECT IT?
A: But how is it possible? If you load it manually twice, then you can delete it by requestID.
Q. CAN U ADD A NEW FIELD AT THE ODS LEVEL?
Sure you can. ODS is nothing but a table.
Q. CAN NUMBER OF DATASOURCES HAVE ONE INFOSOURCE?
A) Yes of course. For example, for loading text and hierarchies we use different data sources but the same InfoSource.
Q. BRIEF THE DATAFLOW IN BW.
A) Data flows from transactional system to analytical system (BW). DataSources on the transactional system needs to be replicated on BW side and attached to infosource and update rules respectively.
Q. CURRENCY CONVERSIONS CAN BE WRITTEN IN UPDATE RULES. WHY NOT IN TRANSFER RULES?
Q) WHAT IS PROCEDURE TO UPDATE DATA INTO DATA TARGETS?
FULL and DELTA.
Q) AS WE USE Sbwnn, sbiw1, sbiw2 for delta update in LIS THEN WHAT IS THE PROCEDURE IN LO-COCKPIT?
No LIS in LO cockpit. We will have datasources and can be maintained (append fields). Refer white paper on LO-Cockpit extractions.
Q) Why we delete the setup tables (LBWG) & fill them (OLI*BW)?
A) Initially we don't delete the setup tables but when we do change in extract structure we go for it. We r changing the extract structure right, that means there are some newly added fields in that which r not before. So to get the required data (i.e.; the data which is required is taken and to avoid redundancy) we delete n then fill the setup tables.
To refresh the statistical data. The extraction set up reads the dataset that you want to process such as, customers orders with the tables like VBAK, VBAP) & fills the relevant communication structure with the data. The data is stored in cluster tables from where it is read when the initialization is run. It is important that during initialization phase, no one generates or modifies application data, at least until the tables can be set up.
Q) SIGNIFICANCE of ODS?
It holds granular data (detailed level).
Q) WHERE THE PSA DATA IS STORED?
In PSA table.
Q) WHAT IS DATA SIZE?
The volume of data one data target holds (in no. of records)
Q) Different types of INFOCUBES.
Basic, Virtual (remote, sap remote and multi)
Virtual Cube is used for example, if you consider railways reservation all the information has to be updated online. For designing the Virtual cube you have to write the function module that is linking to table, Virtual cube it is like a the structure, when ever the table is updated the virtual cube will fetch the data from table and display report Online... FYI.. you will get the information : https://www.sdn.sap.com/sdn/index.sdn and search for Designing Virtual Cube and you will get a good material designing the Function Module
Q) INFOSET QUERY.
Can be made of ODS's and Characteristic InfoObjects with masterdata.
Q) IF THERE ARE 2 DATASOURCES HOW MANY TRANSFER STRUCTURES ARE THERE.
In R/3 or in BW? 2 in R/3 and 2 in BW
Q) ROUTINES?
Exist in the InfoObject, transfer routines, update routines and start routine
Q) BRIEF SOME STRUCTURES USED IN BEX.
Rows and Columns, you can create structures.
Q) WHAT ARE THE DIFFERENT VARIABLES USED IN BEX?
Different Variable's are Texts, Formulas, Hierarchies, Hierarchy nodes & Characteristic values.
Variable Types are
Manual entry /default value
Replacement path
SAP exit
Customer exit
Authorization
Q) HOW MANY LEVELS YOU CAN GO IN REPORTING?
You can drill down to any level by using Navigational attributes and jump targets.
Q) WHAT ARE INDEXES?
Indexes are data base indexes, which help in retrieving data fastly.
Q) DIFFERENCE BETWEEN 2.1 AND 3.X VERSIONS.
Help! Refer documentation
Q) IS IT NESSESARY TO INITIALIZE EACH TIME THE DELTA UPDATE IS USED?
No.
Q) WHAT IS THE SIGNIFICANCE OF KPI'S?
KPI's indicate the performance of a company. These are key figures
Q) AFTER THE DATA EXTRACTION WHAT IS THE IMAGE POSITION.
After image (correct me if I am wrong)
Q) REPORTING AND RESTRICTIONS.
Help! Refer documentation.
Q) TOOLS USED FOR PERFORMANCE TUNING.
ST22, Number ranges, delete indexes before load. Etc
Q) PROCESS CHAINS: IF U has USED IT THEN HOW WILL U SCHEDULING DATA DAILY.
There should be some tool to run the job daily (SM37 jobs)
Q) AUTHORIZATIONS.
Profile generator
Q) WEB REPORTING.
What are you expecting??
Q) CAN CHARECTERSTIC INFOOBJECT CAN BE INFOPROVIDER.
Of course
Q) PROCEDURES OF REPORTING ON MULTICUBES
Refer help. What are you expecting? MultiCube works on Union condition
Q) EXPLAIN TRANPSORTATION OF OBJECTS?
Dev-àQ and Dev-----àP
Q) What types of partitioning are there for BW?
There are two Partitioning Performance aspects for BW (Cube & PSA)
Query Data Retrieval Performance Improvement:
Partitioning by (say) Date Range improves data retrieval by making best use of database execution plans and indexes (of say Oracle database engine).
B) Transactional Load Partitioning Improvement:
Partitioning based on expected load volumes and data element sizes. Improves data loading into PSA and Cubes by infopackages (Eg. without timeouts).
Q) How can I compare data in R/3 with data in a BW Cube after the daily delta loads? Are there any standard procedures for checking them or matching the number of records?
A) You can go to R/3 TCode RSA3 and run the extractor. It will give you the number of records extracted. Then go to BW Monitor to check the number of records in the PSA and check to see if it is the same & also in the monitor header tab.
A) RSA3 is a simple extractor checker program that allows you to rule out extracts problems in R/3. It is simple to use, but only really tells you if the extractor works. Since records that get updated into Cubes/ODS structures are controlled by Update Rules, you will not be able to determine what is in the Cube compared to what is in the R/3 environment. You will need to compare records on a 1:1 basis against records in R/3 transactions for the functional area in question. I would recommend enlisting the help of the end user community to assist since they presumably know the data.
To use RSA3, go to it and enter the extractor ex: 2LIS_02_HDR. Click execute and you will see the record count, you can also go to display that data. You are not modifying anything so what you do in RSA3 has no effect on data quality afterwards. However, it will not tell you how many records should be expected in BW for a given load. You have that information in the monitor RSMO during and after data loads. From RSMO for a given load you can determine how many records were passed through the transfer rules from R/3, how many targets were updated, and how many records passed through the Update Rules. It also gives you error messages from the PSA.
Q) Types of Transfer Rules?
A) Field to Field mapping, Constant, Variable & routine.
Q) Types of Update Rules?
A) (Check box), Return table
Q) Transfer Routine?
A) Routines, which we write in, transfer rules.
Q) Update Routine?
A) Routines, which we write in Update rules
Q) What is the difference between writing a routine in transfer rules and writing a routine in update rules?
A) If you are using the same InfoSource to update data in more than one data target its better u write in transfer rules because u can assign one InfoSource to more than one data target & and what ever logic u write in update rules it is specific to particular one data target.
Q) Routine with Return Table.
A) Update rules generally only have one return value. However, you can create a routine in the tab strip key figure calculation, by choosing checkbox Return table. The corresponding key figure routine then no longer has a return value, but a return table. You can then generate as many key figure values, as you like from one data record.
Q) Start routines?
A) Start routines u can write in both updates rules and transfer rules, suppose you want to restrict (delete) some records based on conditions before getting loaded into data targets, then you can specify this in update rules-start routine.
Ex: - Delete Data_Package ani ante it will delete a record based on the condition
Q) X & Y Tables?
X-table = A table to link material SIDs with SIDs for time-independent navigation attributes.
Y-table = A table to link material SIDs with SIDS for time-dependent navigation attributes.
There are four types of sid tables
X time independent navigational attributes sid tables
Y time dependent navigational attributes sid tables
H hierarchy sid tables
I hierarchy structure sid tables
Q) Filters & Restricted Key figures (real time example)
Restricted KF's u can have for an SD cube: billed quantity, billing value, no: of billing documents as RKF's.
Q) Line-Item Dimension (give me an real time example)
Line-Item Dimension: Invoice no: or Doc no: is a real time example
Q) What does the number in the 'Total' column in Transaction RSA7 mean?
A) The 'Total' column displays the number of LUWs that were written in the delta queue and that have not yet been confirmed. The number includes the LUWs of the last delta request (for repetition of a delta request) and the LUWs for the next delta request. A LUW only disappears from the RSA7 display when it has been transferred to the BW System and a new delta request has been received from the BW System.
Q) How to know in which table (SAP BW) contains Technical Name / Description and creation data of a particular Reports. Reports that are created using BEx Analyzer.
A) There is no such table in BW if you want to know such details while you are opening a particular query press properties button you will come to know all the details that you wanted.
You will find your information about technical names and description about queries in the following tables. Directory of all reports (Table RSRREPDIR) and Directory of the reporting component elements (Table RSZELTDIR) for workbooks and the connections to queries check Where- used list for reports in workbooks (Table RSRWORKBOOK) Titles of Excel Workbooks in InfoCatalog (Table RSRWBINDEXT)
Q) What is a LUW in the delta queue?
A) A LUW from the point of view of the delta queue can be an individual document, a group of documents from a collective run or a whole data packet of an application extractor.
Q) Why does the number in the 'Total' column in the overview screen of Transaction RSA7 differ from the number of data records that is displayed when you call the detail view?
A) The number on the overview screen corresponds to the total of LUWs (see also first question) that were written to the qRFC queue and that have not yet been confirmed. The detail screen displays the records contained in the LUWs. Both, the records belonging to the previous delta request and the records that do not meet the selection conditions of the preceding delta init requests are filtered out. Thus, only the records that are ready for the next delta request are displayed on the detail screen. In the detail screen of Transaction RSA7, a possibly existing customer exit is not taken into account.
Q) Why does Transaction RSA7 still display LUWs on the overview screen after successful delta loading?
A) Only when a new delta has been requested does the source system learn that the previous delta was successfully loaded to the BW System. Then, the LUWs of the previous delta may be confirmed (and also deleted). In the meantime, the LUWs must be kept for a possible delta request repetition. In particular, the number on the overview screen does not change when the first delta was loaded to the BW System.
Q) Why are selections not taken into account when the delta queue is filled?
A) Filtering according to selections takes place when the system reads from the delta queue. This is necessary for reasons of performance.
Q) Why is there a DataSource with '0' records in RSA7 if delta exists and has also been loaded successfully?
It is most likely that this is a DataSource that does not send delta data to the BW System via the delta queue but directly via the extractor (delta for master data using ALE change pointers). Such a DataSource should not be displayed in RSA7. This error is corrected with BW 2.0B Support Package 11.
Q) Do the entries in table ROIDOCPRMS have an impact on the performance of the loading procedure from the delta queue?
A) The impact is limited. If performance problems are related to the loading process from the delta queue, then refer to the application-specific notes (for example in the CO-PA area, in the logistics cockpit area and so on).
Caution: As of Plug In 2000.2 patch 3 the entries in table ROIDOCPRMS are as effective for the delta queue as for a full update. Please note, however, that LUWs are not split during data loading for consistency reasons. This means that when very large LUWs are written to the DeltaQueue, the actual package size may differ considerably from the MAXSIZE and MAXLINES parameters.
Q) Why does it take so long to display the data in the delta queue (for example approximately 2 hours)?
A) With Plug In 2001.1 the display was changed: the user has the option of defining the amount of data to be displayed, to restrict it, to selectively choose the number of a data record, to make a distinction between the 'actual' delta data and the data intended for repetition and so on.
Q) What is the purpose of function 'Delete data and meta data in a queue' in RSA7? What exactly is deleted?
A) You should act with extreme caution when you use the deletion function in the delta queue. It is comparable to deleting an InitDelta in the BW System and should preferably be executed there. You do not only delete all data of this DataSource for the affected BW System, but also lose the entire information concerning the delta initialization. Then you can only request new deltas after another delta initialization.
When you delete the data, the LUWs kept in the qRFC queue for the corresponding target system are confirmed. Physical deletion only takes place in the qRFC outbound queue if there are no more references to the LUWs.
The deletion function is for example intended for a case where the BW System, from which the delta initialization was originally executed, no longer exists or can no longer be accessed.
Q) Why does it take so long to delete from the delta queue (for example half a day)?
A) Import PlugIn 2000.2 patch 3. With this patch the performance during deletion is considerably improved.
Q) Why is the delta queue not updated when you start the V3 update in the logistics cockpit area?
A) It is most likely that a delta initialization had not yet run or that the delta initialization was not successful. A successful delta initialization (the corresponding request must have QM status 'green' in the BW System) is a prerequisite for the application data being written in the delta queue.
Q) What is the relationship between RSA7 and the qRFC monitor (Transaction SMQ1)?
A) The qRFC monitor basically displays the same data as RSA7. The internal queue name must be used for selection on the initial screen of the qRFC monitor. This is made up of the prefix 'BW, the client and the short name of the DataSource. For DataSources whose name are 19 characters long or shorter, the short name corresponds to the name of the DataSource. For DataSources whose name is longer than 19 characters (for delta-capable DataSources only possible as of PlugIn 2001.1) the short name is assigned in table ROOSSHORTN.
In the qRFC monitor you cannot distinguish between repeatable and new LUWs. Moreover, the data of a LUW is displayed in an unstructured manner there.
Q) Why are the data in the delta queue although the V3 update was not started?
A) Data was posted in background. Then, the records are updated directly in the delta queue (RSA7). This happens in particular during automatic goods receipt posting (MRRS). There is no duplicate transfer of records to the BW system. See Note 417189.
Q) Why does button 'Repeatable' on the RSA7 data details screen not only show data loaded into BW during the last delta but also data that were newly added, i.e. 'pure' delta records?
A) Was programmed in a way that the request in repeat mode fetches both actually repeatable (old) data and new data from the source system.
Q) I loaded several delta inits with various selections. For which one is the delta loaded?
A) For delta, all selections made via delta inits are summed up. This means, a delta for the 'total' of all delta initializations is loaded.
Q) How many selections for delta inits are possible in the system?
A) With simple selections (intervals without complicated join conditions or single values), you can make up to about 100 delta inits. It should not be more.
With complicated selection conditions, it should be only up to 10-20 delta inits.
Reason: With many selection conditions that are joined in a complicated way, too many 'where' lines are generated in the generated ABAP source code that may exceed the memory limit.
Q) I intend to copy the source system, i.e. make a client copy. What will happen with may delta? Should I initialize again after that?
A) Before you copy a source client or source system, make sure that your deltas have been fetched from the DeltaQueue into BW and that no delta is pending. After the client copy, an inconsistency might occur between BW delta tables and the OLTP delta tables as described in Note 405943. After the client copy, Table ROOSPRMSC will probably be empty in the OLTP since this table is client-independent. After the system copy, the table will contain the entries with the old logical system name that are no longer useful for further delta loading from the new logical system. The delta must be initialized in any case since delta depends on both the BW system and the source system. Even if no dump 'MESSAGE_TYPE_X' occurs in BW when editing or creating an InfoPackage, you should expect that the delta have to be initialized after the copy.
Q) Is it allowed in Transaction SMQ1 to use the functions for manual control of processes?
A) Use SMQ1 as an instrument for diagnosis and control only. Make changes to BW queues only after informing the BW Support or only if this is explicitly requested in a note for component 'BC-BW' or 'BW-WHM-SAPI'.
Q) Despite of the delta request being started after completion of the collective run (V3 update), it does not contain all documents. Only another delta request loads the missing documents into BW. What is the cause for this "splitting"?
A) The collective run submits the open V2 documents for processing to the task handler, which processes them in one or several parallel update processes in an asynchronous way. For this reason, plan a sufficiently large "safety time window" between the end of the collective run in the source system and the start of the delta request in BW. An alternative solution where this problem does not occur is described in Note 505700.
Q) Despite my deleting the delta init, LUWs are still written into the DeltaQueue?
A) In general, delta initializations and deletions of delta inits should always be carried out at a time when no posting takes place. Otherwise, buffer problems may occur: If a user started the internal mode at a time when the delta initialization was still active, he/she posts data into the queue even though the initialization had been deleted in the meantime. This is the case in your system.
Q) In SMQ1 (qRFC Monitor) I have status 'NOSEND'. In the table TRFCQOUT, some entries have the status 'READY', others 'RECORDED'. ARFCSSTATE is 'READ'. What do these statuses mean? Which values in the field 'Status' mean what and which values are correct and which are alarming? Are the statuses BW-specific or generally valid in qRFC?
A) Table TRFCQOUT and ARFCSSTATE: Status READ means that the record was read once either in a delta request or in a repetition of the delta request. However, this does not mean that the record has successfully reached the BW yet. The status READY in the TRFCQOUT and RECORDED in the ARFCSSTATE means that the record has been written into the DeltaQueue and will be loaded into the BW with the next delta request or a repetition of a delta. In any case only the statuses READ, READY and RECORDED in both tables are considered to be valid. The status EXECUTED in TRFCQOUT can occur temporarily. It is set before starting a DeltaExtraction for all records with status READ present at that time. The records with status EXECUTED are usually deleted from the queue in packages within a delta request directly after setting the status before extracting a new delta. If you see such records, it means that either a process which is confirming and deleting records which have been loaded into the BW is successfully running at the moment, or, if the records remain in the table for a longer period of time with status EXECUTED, it is likely that there are problems with deleting the records which have already been successfully been loaded into the BW. In this state, no more deltas are loaded into the BW. Every other status is an indicator for an error or an inconsistency. NOSEND in SMQ1 means nothing (see note 378903).
The value 'U' in field 'NOSEND' of table TRFCQOUT is discomforting.
Q) The extract structure was changed when the DeltaQueue was empty. Afterwards new delta records were written to the DeltaQueue. When loading the delta into the PSA, it shows that some fields were moved. The same result occurs when the contents of the DeltaQueue are listed via the detail display. Why are the data displayed differently? What can be done?
Make sure that the change of the extract structure is also reflected in the database and that all servers are synchronized. We recommend to reset the buffers using Transaction $SYNC. If the extract structure change is not communicated synchronously to the server where delta records are being created, the records are written with the old structure until the new structure has been generated. This may have disastrous consequences for the delta.
When the problem occurs, the delta needs to be re-initialized.
Q) How and where can I control whether a repeat delta is requested?
A) Via the status of the last delta in the BW Request Monitor. If the request is RED, the next load will be of type 'Repeat'. If you need to repeat the last load for certain reasons, set the request in the monitor to red manually. For the contents of the repeat see Question 14. Delta requests set to red despite of data being already updated lead to duplicate records in a subsequent repeat, if they have not been deleted from the data targets concerned before.
Q) As of PI 2003.1, the Logistic Cockpit offers various types of update methods. Which update method is recommended in logistics? According to which criteria should the decision be made? How can I choose an update method in logistics?
See the recommendation in Note 505700.
Q) Are there particular recommendations regarding the data volume the DeltaQueue may grow to without facing the danger of a read failure due to memory problems?
A) There is no strict limit (except for the restricted number range of the 24-digit QCOUNT counter in the LUW management table - which is of no practical importance, however - or the restrictions regarding the volume and number of records in a database table).
When estimating "smooth" limits, both the number of LUWs is important and the average data volume per LUW. As a rule, we recommend to bundle data (usually documents) already when writing to the DeltaQueue to keep number of LUWs small (partly this can be set in the applications, e.g. in the Logistics Cockpit). The data volume of a single LUW should not be considerably larger than 10% of the memory available to the work process for data extraction (in a 32-bit architecture with a memory volume of about 1GByte per work process, 100 Mbytes per LUW should not be exceeded). That limit is of rather small practical importance as well since a comparable limit already applies when writing to the DeltaQueue. If the limit is observed, correct reading is guaranteed in most cases.
If the number of LUWs cannot be reduced by bundling application transactions, you should at least make sure that the data are fetched from all connected BWs as quickly as possible. But for other, BW-specific, reasons, the frequency should not be higher than one DeltaRequest per hour.
To avoid memory problems, a program-internal limit ensures that never more than 1 million LUWs are read and fetched from the database per DeltaRequest. If this limit is reached within a request, the DeltaQueue must be emptied by several successive DeltaRequests. We recommend, however, to try not to reach that limit but trigger the fetching of data from the connected BWs already when the number of LUWs reaches a 5-digit value.
Q) I would like to display the date the data was uploaded on the report. Usually, we load the transactional data nightly. Is there any easy way to include this information on the report for users? So that they know the validity of the report.
A) If I understand your requirement correctly, you want to display the date on which data was loaded into the data target from which the report is being executed. If it is so, configure your workbook to display the text elements in the report. This displays the relevance of data field, which is the date on which the data load has taken place.
Q) Can we filter the fields at Transfer Structure?
Q) Can we load data directly into infoobject with out extraction is it possible.
Yes. We can copy from other infoobject if it is same. We load data from PSA if it is already in PSA.
Q) HOW MANY DAYS CAN WE KEEP THE DATA IN PSA, IF WE R SHEDULED DAILY, WEEKLY AND MONTHLY.
a) We can set the time.
Q) HOW CAN U GET THE DATA FROM CLIENT IF U R WORKING ON OFFSHORE PROJECTS. THROUGH WHICH NETWORK.
a) VPN .Virtual Private Network, VPN is nothing but one sort of network where we can connect to the client systems sitting in offshore through RAS (Remote access server).
Q) HOW CAN U ANALIZE THE PROJECT AT FIRST?
Prepare Project Plan and Environment
Define Project Management Standards and
Procedures
Define Implementation Standards and Procedures
Testing & Go-live + supporting.
Q) THERE is one ODS AND 4 INFOCUBES. WE SEND DATA AT TIME TO ALL CUBES IF ONE CUBE GOT LOCK ERROR. HOW CAN U RECTIFY THE ERROR?
Go to TCode sm66 then see which one is locked select that pid from there and goto sm12
TCode then unlock it this is happened when lock errors are occurred when u scheduled.
Q) Can anybody tell me how to add a navigational attribute in the BEx report in the rows?
A) Expand dimension under left side panel (that is infocube panel) select than navigational attributes drag and drop under rows panel.
Q) IF ANY TRASACTION CODE LIKE SMPT OR STMT.
In current systems (BW 3.0B and R/3 4.6B) these Tcodes don't exist!
Q) WHAT IS TRANSACTIONAL CUBE?
A) Transactional InfoCubes differ from standard InfoCubes in that the former have an improved write access performance level. Standard InfoCubes are technically optimized for read-only access and for a comparatively small number of simultaneous accesses. Instead, the transactional InfoCube was developed to meet the demands of SAP Strategic Enterprise Management (SEM), meaning that, data is written to the InfoCube (possibly by several users at the same time) and re-read as soon as possible. Standard Basic cubes are not suitable for this.
Q) Is there any way to delete cube contents within update rules from an ODS data source? The reason for this would be to delete (or zero out) a cube record in an "Open Order" cube if the open order quantity was 0.
I've tried using the 0recordmode but that doesn't work. Also, would it
be easier to write a program that would be run after the load and delete
the records with a zero open qty?
A) START routine for update rules u can write ABAP code.
A) Yap, you can do it. Create a start routine in Update rule.
It is not "Deleting cube contents with update rules" It is only possible to avoid that some content is updated into the InfoCube using the start routine. Loop at all the records and delete the record that has the condition. "If the open order quantity was 0" You have to think also in before and after images in case of a delta upload. In that case you may delete the change record and keep the old and after the change the wrong information.
Q) I am not able to access a node in hierarchy directly using variables for reports. When I am using Tcode RSZV it is giving a message that it doesn't exist in BW 3.0 and it is embedded in BEx. Can any one tell me the other options to get the same functionality in BEx?
A) Tcode RSZV is used in the earlier version of 3.0B only. From 3.0B onwards, it's possible in the Query Designer (BEx) itself. Just right click on the InfoObject for which you want to use as variables and precede further selecting variable type and processing types.
Q) Wondering how can I get the values, for an example, if I run a report for month range 01/2004 - 10/2004 then monthly value is actually divide by the number of months that I selected. Which variable should I use?
Q) Why is it every time I switch from Info Provider to InfoObject or from one item to another while in modeling I always get this message " Reading Data " or "constructing workbench" in it runs for minutes.... anyway to stop this?
Q) Can any one give me info on how the BW delta works also would like to know about 'before image and after image' am currently in a BW project and have to write start routines for delta load.
Q) I am very new to BW. I would like to clarify a doubt regarding Delta extractor. If I am correct, by using delta extractors the data that has already been scheduled will not be uploaded again. Say for a specific scenario, Sales. Now I have uploaded all the sales order created till yesterday into the cube. Now say I make changes to any of the open record, which was already uploaded. Now what happens when I schedule it again? Will the same record be uploaded again with the changes or will the changes get affected to the previous record.
A)
Q) In BW we need to write abap routines. I wish to know when and what type of abap routines we got to write. Also, are these routines written in update rules? I will be glad, if this is clarified with real-time scenarios and few examples?
A) Over here we write our routines in the start routines in the update rules or in the transfer structure (you can choose between writing them in the start routines or directly behind the different characteristics. In the transfer structure you just click on the yellow triangle behind a characteristic and choose "routine". In the update rules you can choose "start routine" or click on the triangle with the green square behind an individual characteristic. Usually we only use start routine when it does not concern one single characteristic (for example when you have to read the same table for 4 characteristics). I hope this helps.
We used ABAP Routines for example:
To convert to Uppercase (transfer structure)
To convert Values out of a third party tool with different keys into the same keys as our SAP System uses (transfer structure)
To select only a part of the data for from an infosource updating the InfoCube (Start Routine) etc.
Q) What is ODS?
A) An ODS object acts as a storage location for consolidated and cleaned-up transaction data (transaction data or master data, for example) on the document (atomic) level.
This data can be evaluated using a BEx query.
Standard ODS Object
Transactional ODS object:
The data is immediately available here for reporting. For implementation, compare with the Transactional ODS Object.
A transactional ODS object differs from a standard ODS object in the way it prepares data. In a standard ODS object, data is stored in different versions ((new) delta, active, (change log) modified), where as a transactional ODS object contains the data in a single version. Therefore, data is stored in precisely the same form in which it was written to the transactional ODS object by the application. In BW, you can use a transaction ODS object as a data target for an analysis process.
The transactional ODS object is also required by diverse applications, such as SAP Strategic Enterprise Management (SEM) for example, as well as other external applications.
Transactional ODS objects allow data to be available quickly. The data from this kind of ODS object is accessed transactionally, that is, data is written to the ODS object (possibly by several users at the same time) and reread as soon as possible.
It offers no replacement for the standard ODS object. Instead, an additional function displays those that can be used for special applications.
The transactional ODS object simply consists of a table for active data. It retrieves its data from external systems via fill- or delete- APIs. The loading process is not supported by the BW system. The advantage to the way it is structured is that data is easy to access. They are made available for reporting immediately after being loaded.
Q) What does InfoCube contains?
A) Each InfoCube has one FactTable & a maximum of 16 (13+3 system defined, time, unit & data packet) dimensions.
Q) What does FACT Table contain?
A FactTable consists of KeyFigures.
Each Fact Table can contain a maximum of 233 key figures.
Dimension can contain up to 248 freely available characteristics.
Q) How many dimensions are in a CUBE?
A) 16 dimensions. (13 user defined & 3 system pre-defined )
Q) What does SID Table contain?
SID keys linked with dimension table & master data tables (attributes, texts, hierarchies)
Q) What does ATTRIBUTE Table contain?
Master attribute data
Q) What does TEXT Table contain?
Master text data, short text, long text, medium text & language key if it is language dependent
Q) What does Hierarchy table contain?Hi DST
This is a great effort and gesture. thank you on behalf of all the newbies.
PJ -
HI,
friends i need some FAQS for the interviews .
thanks and regards
shafeeq ahmedHi Shafeed,
Here are some questions and answers.
1)name the two table that providedetail information about data source
2)how and when can you control whether repeat delta is requested?
3)how can you improve the performance of aquery
4)how to prevent duplicate record in at the data target level
5)what is virtual cube?its significance
6)diff methods of generic datasource
7)how to connect anew data target to an existing data flow
8)what is partition
9) SAP batch process
10)how do you improve the info cube design preformance
12)is there any diff between repair run/repaire request.if yes then please tell me in detail
13)difference between process chain and infopackage group
diff between partition/aggregate
ANS--
1) Hi Santosh
Please find some of the answers here...
For Q 3) Query Performance can be improved by making the Aggregates having all the Chars & KF used in Query.
Q 5) Virtual Cube : InfoProvider with transaction data that is not stored in the object itself, but which is read directly for analysis and reporting purposes. The relevant data can be from the BI system or from other SAP or non-SAP systems.
VirtualProviders only allow read access to data.
Q 6) Diff Methods of Generic datasource using Transaction RSO2 :
a) Extraction from DB Table or View
b) Extraction from SAP Query
c) Extraction by Function Module
2) Important BW datasource relevant tables
ROOSOURCE: Table Header for SAP BW OLTP Sources
RODELTAM: BW Delta Process
ROOSFIELD: DataSource Fields
ROOSGEN: Generated Objects for OLTP Source, Last changed date and who etc.
3) For Q 8) i think you mean table partition
You use partition to improve performance. You can only partiton on 0CALMONTH or 0FISCPER
4) 1. ROOSOURCE
6. Generic Extarction using 1.Views 2. Infoset Queries , 3. Function modules
5) Hi Santosh
Pls note down the Q& ANS
Some of the Real time question.
Q) Under which menu path is the Test Workbench to be found, including in earlier Releases?
The menu path is: Tools - ABAP Workbench - Test - Test Workbench.
Q) I want to delete a BEx query that is in Production system through request. Is anyone aware about it?
A) Have you tried the RSZDELETE transaction?
Q) Errors while monitoring process chains.
A) During data loading. Apart from them, in process chains you add so many process types, for example after loading data into Info Cube, you rollup data into aggregates, now this rolling up of data into aggregates is a process type which you keep after the process type for loading data into Cube. This rolling up into aggregates might fail.
Another one is after you load data into ODS, you activate ODS data (another process type) this might also fail.
Q) In Monitor----- Details (Header/Status/Details) à Under Processing (data packet): Everything OK à Context menu of Data Package 1 (1 Records): Everything OK -
Simulate update. (Here we can debug update rules or transfer rules.)
SM50 à Program/Mode à Program à Debugging & debug this work process.
Q) PSA Cleansing.
A) You know how to edit PSA. I don't think you can delete single records. You have to delete entire PSA data for a request.
Q) Can we make a datasource to support delta.
A) If this is a custom (user-defined) datasource you can make the datasource delta enabled. While creating datasource from RSO2, after entering datasource name and pressing create, in the next screen there is one button at the top, which says generic delta. If you want more details about this there is a chapter in Extraction book, it's in last pages u find out.
Generic delta services: -
Supports delta extraction for generic extractors according to:
Time stamp
Calendar day
Numeric pointer, such as document number & counter
Only one of these attributes can be set as a delta attribute.
Delta extraction is supported for all generic extractors, such as tables/views, SAP Query and function modules
The delta queue (RSA7) allows you to monitor the current status of the delta attribute
Q) Workbooks, as a general rule, should be transported with the role.
Here are a couple of scenarios:
1. If both the workbook and its role have been previously transported, then the role does not need to be part of the transport.
2. If the role exists in both dev and the target system but the workbook has never been transported, and then you have a choice of transporting the role (recommended) or just the workbook. If only the workbook is transported, then an additional step will have to be taken after import: Locate the WorkbookID via Table RSRWBINDEXT (in Dev and verify the same exists in the target system) and proceed to manually add it to the role in the target system via Transaction Code PFCG -- ALWAYS use control c/control v copy/paste for manually adding!
3. If the role does not exist in the target system you should transport both the role and workbook. Keep in mind that a workbook is an object unto itself and has no dependencies on other objects. Thus, you do not receive an error message from the transport of 'just a workbook' -- even though it may not be visible, it will exist (verified via Table RSRWBINDEXT).
Overall, as a general rule, you should transport roles with workbooks.
Q) How much time does it take to extract 1 million (10 lackhs) of records into an infocube?
A. This depends, if you have complex coding in update rules it will take longer time, or else it will take less than 30 minutes.
Q) What are the five ASAP Methodologies?
A: Project plan, Business Blue print, Realization, Final preparation & Go-Live - support.
1. Project Preparation: In this phase, decision makers define clear project objectives and an efficient decision making process (i.e. Discussions with the client, like what are his needs and requirements etc.). Project managers will be involved in this phase (I guess).
A Project Charter is issued and an implementation strategy is outlined in this phase.
2. Business Blueprint: It is a detailed documentation of your company's requirements. (i.e. what are the objects we need to develop are modified depending on the client's requirements).
3. Realization: In this only, the implementation of the project takes place (development of objects etc) and we are involved in the project from here only.
4. Final Preparation: Final preparation before going live i.e. testing, conducting pre-go-live, end user training etc.
End user training is given that is in the client site you train them how to work with the new environment, as they are new to the technology.
5. Go-Live & support: The project has gone live and it is into production. The Project team will be supporting the end users.
Q) What is landscape of R/3 & what is landscape of BW. Landscape of R/3 not sure.
Then Landscape of b/w: u have the development system, testing system, production system
Development system: All the implementation part is done in this sys. (I.e., Analysis of objects developing, modification etc) and from here the objects are transported to the testing system, but before transporting an initial test known as Unit testing (testing of objects) is done in the development sys.
Testing/Quality system: quality check is done in this system and integration testing is done.
Production system: All the extraction part takes place in this sys.
Q) How do you measure the size of infocube?
A: In no of records.
Q). Difference between infocube and ODS?
A: Infocube is structured as star schema (extended) where a fact table is surrounded by different dim table that are linked with DIM'ids. And the data wise, you will have aggregated data in the cubes. No overwrite functionality
ODS is a flat structure (flat table) with no star schema concept and which will have granular data (detailed level). Overwrite functionality.
Flat file datasources does not support 0recordmode in extraction.
x before, -after, n new, a add, d delete, r reverse
Q) Difference between display attributes and navigational attributes?
A: Display attribute is one, which is used only for display purpose in the report. Where as navigational attribute is used for drilling down in the report. We don't need to maintain Navigational attribute in the cube as a characteristic (that is the advantage) to drill down.
Q. SOME DATA IS UPLOADED TWICE INTO INFOCUBE. HOW TO CORRECT IT?
A: But how is it possible? If you load it manually twice, then you can delete it by requestID.
Q. CAN U ADD A NEW FIELD AT THE ODS LEVEL?
Sure you can. ODS is nothing but a table.
Q. CAN NUMBER OF DATASOURCES HAVE ONE INFOSOURCE?
A) Yes of course. For example, for loading text and hierarchies we use different data sources but the same InfoSource.
Q. BRIEF THE DATAFLOW IN BW.
A) Data flows from transactional system to analytical system (BW). DataSources on the transactional system needs to be replicated on BW side and attached to infosource and update rules respectively.
Q. CURRENCY CONVERSIONS CAN BE WRITTEN IN UPDATE RULES. WHY NOT IN TRANSFER RULES?
Q) WHAT IS PROCEDURE TO UPDATE DATA INTO DATA TARGETS?
FULL and DELTA.
Q) AS WE USE Sbwnn, sbiw1, sbiw2 for delta update in LIS THEN WHAT IS THE PROCEDURE IN LO-COCKPIT?
No LIS in LO cockpit. We will have datasources and can be maintained (append fields). Refer white paper on LO-Cockpit extractions.
Q) Why we delete the setup tables (LBWG) & fill them (OLI*BW)?
A) Initially we don't delete the setup tables but when we do change in extract structure we go for it. We r changing the extract structure right, that means there are some newly added fields in that which r not before. So to get the required data (i.e.; the data which is required is taken and to avoid redundancy) we delete n then fill the setup tables.
To refresh the statistical data. The extraction set up reads the dataset that you want to process such as, customers orders with the tables like VBAK, VBAP) & fills the relevant communication structure with the data. The data is stored in cluster tables from where it is read when the initialization is run. It is important that during initialization phase, no one generates or modifies application data, at least until the tables can be set up.
Q) SIGNIFICANCE of ODS?
It holds granular data (detailed level).
Q) WHERE THE PSA DATA IS STORED?
In PSA table.
Q) WHAT IS DATA SIZE?
The volume of data one data target holds (in no. of records)
Q) Different types of INFOCUBES.
Basic, Virtual (remote, sap remote and multi)
Virtual Cube is used for example, if you consider railways reservation all the information has to be updated online. For designing the Virtual cube you have to write the function module that is linking to table, Virtual cube it is like a the structure, when ever the table is updated the virtual cube will fetch the data from table and display report Online... FYI.. you will get the information : https://www.sdn.sap.com/sdn/index.sdn and search for Designing Virtual Cube and you will get a good material designing the Function Module
Q) INFOSET QUERY.
Can be made of ODS's and Characteristic InfoObjects with masterdata.
Q) IF THERE ARE 2 DATASOURCES HOW MANY TRANSFER STRUCTURES ARE THERE.
In R/3 or in BW? 2 in R/3 and 2 in BW
Q) ROUTINES?
Exist in the InfoObject, transfer routines, update routines and start routine
Q) BRIEF SOME STRUCTURES USED IN BEX.
Rows and Columns, you can create structures.
Q) WHAT ARE THE DIFFERENT VARIABLES USED IN BEX?
Different Variable's are Texts, Formulas, Hierarchies, Hierarchy nodes & Characteristic values.
Variable Types are
Manual entry /default value
Replacement path
SAP exit
Customer exit
Authorization
Q) HOW MANY LEVELS YOU CAN GO IN REPORTING?
You can drill down to any level by using Navigational attributes and jump targets.
Q) WHAT ARE INDEXES?
Indexes are data base indexes, which help in retrieving data fastly.
Q) DIFFERENCE BETWEEN 2.1 AND 3.X VERSIONS.
Help! Refer documentation
Q) IS IT NESSESARY TO INITIALIZE EACH TIME THE DELTA UPDATE IS USED?
No.
Q) WHAT IS THE SIGNIFICANCE OF KPI'S?
KPI's indicate the performance of a company. These are key figures
Q) AFTER THE DATA EXTRACTION WHAT IS THE IMAGE POSITION.
After image (correct me if I am wrong)
Q) REPORTING AND RESTRICTIONS.
Help! Refer documentation.
Q) TOOLS USED FOR PERFORMANCE TUNING.
ST22, Number ranges, delete indexes before load. Etc
Q) PROCESS CHAINS: IF U has USED IT THEN HOW WILL U SCHEDULING DATA DAILY.
There should be some tool to run the job daily (SM37 jobs)
Q) AUTHORIZATIONS.
Profile generator
Q) WEB REPORTING.
What are you expecting??
Q) CAN CHARECTERSTIC INFOOBJECT CAN BE INFOPROVIDER.
Of course
Q) PROCEDURES OF REPORTING ON MULTICUBES
Refer help. What are you expecting? MultiCube works on Union condition
Q) EXPLAIN TRANPSORTATION OF OBJECTS?
Dev-àQ and Dev-----àP
Q) What types of partitioning are there for BW?
There are two Partitioning Performance aspects for BW (Cube & PSA)
Query Data Retrieval Performance Improvement:
Partitioning by (say) Date Range improves data retrieval by making best use of database execution plans and indexes (of say Oracle database engine).
B) Transactional Load Partitioning Improvement:
Partitioning based on expected load volumes and data element sizes. Improves data loading into PSA and Cubes by infopackages (Eg. without timeouts).
Q) How can I compare data in R/3 with data in a BW Cube after the daily delta loads? Are there any standard procedures for checking them or matching the number of records?
A) You can go to R/3 TCode RSA3 and run the extractor. It will give you the number of records extracted. Then go to BW Monitor to check the number of records in the PSA and check to see if it is the same & also in the monitor header tab.
A) RSA3 is a simple extractor checker program that allows you to rule out extracts problems in R/3. It is simple to use, but only really tells you if the extractor works. Since records that get updated into Cubes/ODS structures are controlled by Update Rules, you will not be able to determine what is in the Cube compared to what is in the R/3 environment. You will need to compare records on a 1:1 basis against records in R/3 transactions for the functional area in question. I would recommend enlisting the help of the end user community to assist since they presumably know the data.
To use RSA3, go to it and enter the extractor ex: 2LIS_02_HDR. Click execute and you will see the record count, you can also go to display that data. You are not modifying anything so what you do in RSA3 has no effect on data quality afterwards. However, it will not tell you how many records should be expected in BW for a given load. You have that information in the monitor RSMO during and after data loads. From RSMO for a given load you can determine how many records were passed through the transfer rules from R/3, how many targets were updated, and how many records passed through the Update Rules. It also gives you error messages from the PSA.
Q) Types of Transfer Rules?
A) Field to Field mapping, Constant, Variable & routine.
Q) Types of Update Rules?
A) (Check box), Return table
Q) Transfer Routine?
A) Routines, which we write in, transfer rules.
Q) Update Routine?
A) Routines, which we write in Update rules
Q) What is the difference between writing a routine in transfer rules and writing a routine in update rules?
A) If you are using the same InfoSource to update data in more than one data target its better u write in transfer rules because u can assign one InfoSource to more than one data target & and what ever logic u write in update rules it is specific to particular one data target.
Q) Routine with Return Table.
A) Update rules generally only have one return value. However, you can create a routine in the tab strip key figure calculation, by choosing checkbox Return table. The corresponding key figure routine then no longer has a return value, but a return table. You can then generate as many key figure values, as you like from one data record.
Q) Start routines?
A) Start routines u can write in both updates rules and transfer rules, suppose you want to restrict (delete) some records based on conditions before getting loaded into data targets, then you can specify this in update rules-start routine.
Ex: - Delete Data_Package ani ante it will delete a record based on the condition
Q) X & Y Tables?
X-table = A table to link material SIDs with SIDs for time-independent navigation attributes.
Y-table = A table to link material SIDs with SIDS for time-dependent navigation attributes.
There are four types of sid tables
X time independent navigational attributes sid tables
Y time dependent navigational attributes sid tables
H hierarchy sid tables
I hierarchy structure sid tables
Q) Filters & Restricted Key figures (real time example)
Restricted KF's u can have for an SD cube: billed quantity, billing value, no: of billing documents as RKF's.
Q) Line-Item Dimension (give me an real time example)
Line-Item Dimension: Invoice no: or Doc no: is a real time example
Q) What does the number in the 'Total' column in Transaction RSA7 mean?
A) The 'Total' column displays the number of LUWs that were written in the delta queue and that have not yet been confirmed. The number includes the LUWs of the last delta request (for repetition of a delta request) and the LUWs for the next delta request. A LUW only disappears from the RSA7 display when it has been transferred to the BW System and a new delta request has been received from the BW System.
Q) How to know in which table (SAP BW) contains Technical Name / Description and creation data of a particular Reports. Reports that are created using BEx Analyzer.
A) There is no such table in BW if you want to know such details while you are opening a particular query press properties button you will come to know all the details that you wanted.
You will find your information about technical names and description about queries in the following tables. Directory of all reports (Table RSRREPDIR) and Directory of the reporting component elements (Table RSZELTDIR) for workbooks and the connections to queries check Where- used list for reports in workbooks (Table RSRWORKBOOK) Titles of Excel Workbooks in InfoCatalog (Table RSRWBINDEXT)
Q) What is a LUW in the delta queue?
A) A LUW from the point of view of the delta queue can be an individual document, a group of documents from a collective run or a whole data packet of an application extractor.
Q) Why does the number in the 'Total' column in the overview screen of Transaction RSA7 differ from the number of data records that is displayed when you call the detail view?
A) The number on the overview screen corresponds to the total of LUWs (see also first question) that were written to the qRFC queue and that have not yet been confirmed. The detail screen displays the records contained in the LUWs. Both, the records belonging to the previous delta request and the records that do not meet the selection conditions of the preceding delta init requests are filtered out. Thus, only the records that are ready for the next delta request are displayed on the detail screen. In the detail screen of Transaction RSA7, a possibly existing customer exit is not taken into account.
Q) Why does Transaction RSA7 still display LUWs on the overview screen after successful delta loading?
A) Only when a new delta has been requested does the source system learn that the previous delta was successfully loaded to the BW System. Then, the LUWs of the previous delta may be confirmed (and also deleted). In the meantime, the LUWs must be kept for a possible delta request repetition. In particular, the number on the overview screen does not change when the first delta was loaded to the BW System.
Q) Why are selections not taken into account when the delta queue is filled?
A) Filtering according to selections takes place when the system reads from the delta queue. This is necessary for reasons of performance.
Q) Why is there a DataSource with '0' records in RSA7 if delta exists and has also been loaded successfully?
It is most likely that this is a DataSource that does not send delta data to the BW System via the delta queue but directly via the extractor (delta for master data using ALE change pointers). Such a DataSource should not be displayed in RSA7. This error is corrected with BW 2.0B Support Package 11.
Q) Do the entries in table ROIDOCPRMS have an impact on the performance of the loading procedure from the delta queue?
A) The impact is limited. If performance problems are related to the loading process from the delta queue, then refer to the application-specific notes (for example in the CO-PA area, in the logistics cockpit area and so on).
Caution: As of Plug In 2000.2 patch 3 the entries in table ROIDOCPRMS are as effective for the delta queue as for a full update. Please note, however, that LUWs are not split during data loading for consistency reasons. This means that when very large LUWs are written to the DeltaQueue, the actual package size may differ considerably from the MAXSIZE and MAXLINES parameters.
Q) Why does it take so long to display the data in the delta queue (for example approximately 2 hours)?
A) With Plug In 2001.1 the display was changed: the user has the option of defining the amount of data to be displayed, to restrict it, to selectively choose the number of a data record, to make a distinction between the 'actual' delta data and the data intended for repetition and so on.
Q) What is the purpose of function 'Delete data and meta data in a queue' in RSA7? What exactly is deleted?
A) You should act with extreme caution when you use the deletion function in the delta queue. It is comparable to deleting an InitDelta in the BW System and should preferably be executed there. You do not only delete all data of this DataSource for the affected BW System, but also lose the entire information concerning the delta initialization. Then you can only request new deltas after another delta initialization.
When you delete the data, the LUWs kept in the qRFC queue for the corresponding target system are confirmed. Physical deletion only takes place in the qRFC outbound queue if there are no more references to the LUWs.
The deletion function is for example intended for a case where the BW System, from which the delta initialization was originally executed, no longer exists or can no longer be accessed.
Q) Why does it take so long to delete from the delta queue (for example half a day)?
A) Import PlugIn 2000.2 patch 3. With this patch the performance during deletion is considerably improved.
Q) Why is the delta queue not updated when you start the V3 update in the logistics cockpit area?
A) It is most likely that a delta initialization had not yet run or that the delta initialization was not successful. A successful delta initialization (the corresponding request must have QM status 'green' in the BW System) is a prerequisite for the application data being written in the delta queue.
Q) What is the relationship between RSA7 and the qRFC monitor (Transaction SMQ1)?
A) The qRFC monitor basically displays the same data as RSA7. The internal queue name must be used for selection on the initial screen of the qRFC monitor. This is made up of the prefix 'BW, the client and the short name of the DataSource. For DataSources whose name are 19 characters long or shorter, the short name corresponds to the name of the DataSource. For DataSources whose name is longer than 19 characters (for delta-capable DataSources only possible as of PlugIn 2001.1) the short name is assigned in table ROOSSHORTN.
In the qRFC monitor you cannot distinguish between repeatable and new LUWs. Moreover, the data of a LUW is displayed in an unstructured manner there.
Q) Why are the data in the delta queue although the V3 update was not started?
A) Data was posted in background. Then, the records are updated directly in the delta queue (RSA7). This happens in particular during automatic goods receipt posting (MRRS). There is no duplicate transfer of records to the BW system. See Note 417189.
Q) Why does button 'Repeatable' on the RSA7 data details screen not only show data loaded into BW during the last delta but also data that were newly added, i.e. 'pure' delta records?
A) Was programmed in a way that the request in repeat mode fetches both actually repeatable (old) data and new data from the source system.
Q) I loaded several delta inits with various selections. For which one is the delta loaded?
A) For delta, all selections made via delta inits are summed up. This means, a delta for the 'total' of all delta initializations is loaded.
Q) How many selections for delta inits are possible in the system?
A) With simple selections (intervals without complicated join conditions or single values), you can make up to about 100 delta inits. It should not be more.
With complicated selection conditions, it should be only up to 10-20 delta inits.
Reason: With many selection conditions that are joined in a complicated way, too many 'where' lines are generated in the generated ABAP source code that may exceed the memory limit.
Q) I intend to copy the source system, i.e. make a client copy. What will happen with may delta? Should I initialize again after that?
A) Before you copy a source client or source system, make sure that your deltas have been fetched from the DeltaQueue into BW and that no delta is pending. After the client copy, an inconsistency might occur between BW delta tables and the OLTP delta tables as described in Note 405943. After the client copy, Table ROOSPRMSC will probably be empty in the OLTP since this table is client-independent. After the system copy, the table will contain the entries with the old logical system name that are no longer useful for further delta loading from the new logical system. The delta must be initialized in any case since delta depends on both the BW system and the source system. Even if no dump 'MESSAGE_TYPE_X' occurs in BW when editing or creating an InfoPackage, you should expect that the delta have to be initialized after the copy.
Q) Is it allowed in Transaction SMQ1 to use the functions for manual control of processes?
A) Use SMQ1 as an instrument for diagnosis and control only. Make changes to BW queues only after informing the BW Support or only if this is explicitly requested in a note for component 'BC-BW' or 'BW-WHM-SAPI'.
Q) Despite of the delta request being started after completion of the collective run (V3 update), it does not contain all documents. Only another delta request loads the missing documents into BW. What is the cause for this "splitting"?
A) The collective run submits the open V2 documents for processing to the task handler, which processes them in one or several parallel update processes in an asynchronous way. For this reason, plan a sufficiently large "safety time window" between the end of the collective run in the source system and the start of the delta request in BW. An alternative solution where this problem does not occur is described in Note 505700.
Q) Despite my deleting the delta init, LUWs are still written into the DeltaQueue?
A) In general, delta initializations and deletions of delta inits should always be carried out at a time when no posting takes place. Otherwise, buffer problems may occur: If a user started the internal mode at a time when the delta initialization was still active, he/she posts data into the queue even though the initialization had been deleted in the meantime. This is the case in your system.
Q) In SMQ1 (qRFC Monitor) I have status 'NOSEND'. In the table TRFCQOUT, some entries have the status 'READY', others 'RECORDED'. ARFCSSTATE is 'READ'. What do these statuses mean? Which values in the field 'Status' mean what and which values are correct and which are alarming? Are the statuses BW-specific or generally valid in qRFC?
A) Table TRFCQOUT and ARFCSSTATE: Status READ means that the record was read once either in a delta request or in a repetition of the delta request. However, this does not mean that the record has successfully reached the BW yet. The status READY in the TRFCQOUT and RECORDED in the ARFCSSTATE means that the record has been written into the DeltaQueue and will be loaded into the BW with the next delta request or a repetition of a delta. In any case only the statuses READ, READY and RECORDED in both tables are considered to be valid. The status EXECUTED in TRFCQOUT can occur temporarily. It is set before starting a DeltaExtraction for all records with status READ present at that time. The records with status EXECUTED are usually deleted from the queue in packages within a delta request directly after setting the status before extracting a new delta. If you see such records, it means that either a process which is confirming and deleting records which have been loaded into the BW is successfully running at the moment, or, if the records remain in the table for a longer period of time with status EXECUTED, it is likely that there are problems with deleting the records which have already been successfully been loaded into the BW. In this state, no more deltas are loaded into the BW. Every other status is an indicator for an error or an inconsistency. NOSEND in SMQ1 means nothing (see note 378903).
The value 'U' in field 'NOSEND' of table TRFCQOUT is discomforting.
Q) The extract structure was changed when the DeltaQueue was empty. Afterwards new delta records were written to the DeltaQueue. When loading the delta into the PSA, it shows that some fields were moved. The same result occurs when the contents of the DeltaQueue are listed via the detail display. Why are the data displayed differently? What can be done?
Make sure that the change of the extract structure is also reflected in the database and that all servers are synchronized. We recommend to reset the buffers using Transaction $SYNC. If the extract structure change is not communicated synchronously to the server where delta records are being created, the records are written with the old structure until the new structure has been generated. This may have disastrous consequences for the delta.
When the problem occurs, the delta needs to be re-initialized.
Q) How and where can I control whether a repeat delta is requested?
A) Via the status of the last delta in the BW Request Monitor. If the request is RED, the next load will be of type 'Repeat'. If you need to repeat the last load for certain reasons, set the request in the monitor to red manually. For the contents of the repeat see Question 14. Delta requests set to red despite of data being already updated lead to duplicate records in a subsequent repeat, if they have not been deleted from the data targets concerned before.
Q) As of PI 2003.1, the Logistic Cockpit offers various types of update methods. Which update method is recommended in logistics? According to which criteria should the decision be made? How can I choose an update method in logistics?
See the recommendation in Note 505700.
Q) Are there particular recommendations regarding the data volume the DeltaQueue may grow to without facing the danger of a read failure due to memory problems?
A) There is no strict limit (except for the restricted number range of the 24-digit QCOUNT counter in the LUW management table - which is of no practical importance, however - or the restrictions regarding the volume and number of records in a database table).
When estimating "smooth" limits, both the number of LUWs is important and the average data volume per LUW. As a rule, we recommend to bundle data (usually documents) already when writing to the DeltaQueue to keep number of LUWs small (partly this can be set in the applications, e.g. in the Logistics Cockpit). The data volume of a single LUW should not be considerably larger than 10% of the memory available to the work process for data extraction (in a 32-bit architecture with a memory volume of about 1GByte per work process, 100 Mbytes per LUW should not be exceeded). That limit is of rather small practical importance as well since a comparable limit already applies when writing to the DeltaQueue. If the limit is observed, correct reading is guaranteed in most cases.
If the number of LUWs cannot be reduced by bundling application transactions, you should at least make sure that the data are fetched from all connected BWs as quickly as possible. But for other, BW-specific, reasons, the frequency should not be higher than one DeltaRequest per hour.
To avoid memory problems, a program-internal limit ensures that never more than 1 million LUWs are read and fetched from the database per DeltaRequest. If this limit is reached within a request, the DeltaQueue must be emptied by several successive DeltaRequests. We recommend, however, to try not to reach that limit but trigger the fetching of data from the connected BWs already when the number of LUWs reaches a 5-digit value.
Q) I would like to display the date the data was uploaded on the report. Usually, we load the transactional data nightly. Is there any easy way to include this information on the report for users? So that they know the validity of the report.
A) If I understand your requirement correctly, you want to display the date on which data was loaded into the data target from which the report is being executed. If it is so, configure your workbook to display the text elements in the report. This displays the relevance of data field, which is the date on which the data load has taken place.
Q) Can we filter the fields at Transfer Structure?
Q) Can we load data directly into infoobject with out extraction is it possible.
Yes. We can copy from other infoobject if it is same. We load data from PSA if it is already in PSA.
Q) HOW MANY DAYS CAN WE KEEP THE DATA IN PSA, IF WE R SHEDULED DAILY, WEEKLY AND MONTHLY.
a) We can set the time.
Q) HOW CAN U GET THE DATA FROM CLIENT IF U R WORKING ON OFFSHORE PROJECTS. THROUGH WHICH NETWORK.
a) VPN .Virtual Private Network, VPN is nothing but one sort of network where we can connect to the client systems sitting in offshore through RAS (Remote access server).
Q) HOW CAN U ANALIZE THE PROJECT AT FIRST?
Prepare Project Plan and Environment
Define Project Management Standards and
Procedures
Define Implementation Standards and Procedures
Testing & Go-live + supporting.
Q) THERE is one ODS AND 4 INFOCUBES. WE SEND DATA AT TIME TO ALL CUBES IF ONE CUBE GOT LOCK ERROR. HOW CAN U RECTIFY THE ERROR?
Go to TCode sm66 then see which one is locked select that pid from there and goto sm12
TCode then unlock it this is happened when lock errors are occurred when u scheduled.
Q) Can anybody tell me how to add a navigational attribute in the BEx report in the rows?
A) Expand dimension under left side panel (that is infocube panel) select than navigational attributes drag and drop under rows panel.
Q) IF ANY TRASACTION CODE LIKE SMPT OR STMT.
In current systems (BW 3.0B and R/3 4.6B) these Tcodes don't exist!
Q) WHAT IS TRANSACTIONAL CUBE?
A) Transactional InfoCubes differ from standard InfoCubes in that the former have an improved write access performance level. Standard InfoCubes are technically optimized for read-only access and for a comparatively small number of simultaneous accesses. Instead, the transactional InfoCube was developed to meet the demands of SAP Strategic Enterprise Management (SEM), meaning that, data is written to the InfoCube (possibly by several users at the same time) and re-read as soon as possible. Standard Basic cubes are not suitable for this.
Q) Is there any way to delete cube contents within update rules from an ODS data source? The reason for this would be to delete (or zero out) a cube record in an "Open Order" cube if the open order quantity was 0.
I've tried using the 0recordmode but that doesn't work. Also, would it
be easier to write a program that would be run after the load and delete
the records with a zero open qty?
A) START routine for update rules u can write ABAP code.
A) Yap, you can do it. Create a start routine in Update rule.
It is not "Deleting cube contents with update rules" It is only possible to avoid that some content is updated into the InfoCube using the start routine. Loop at all the records and delete the record that has the condition. "If the open order quantity was 0" You have to think also in before and after images in case of a delta upload. In that case you may delete the change record and keep the old and after the change the wrong information.
Q) I am not able to access a node in hierarchy directly using variables for reports. When I am using Tcode RSZV it is giving a message that it doesn't exist in BW 3.0 and it is embedded in BEx. Can any one tell me the other options to get the same functionality in BEx?
A) Tcode RSZV is used in the earlier version of 3.0B only. From 3.0B onwards, it's possible in the Query Designer (BEx) itself. Just right click on the InfoObject for which you want to use as variables and precede further selecting variable type and processing types.
Q) Wondering how can I get the values, for an example, if I run a report for month range 01/2004 - 10/2004 then monthly value is actually divide by the number of months that I selected. Which variable should I use?
Q) Why is it every time I switch from Info Provider to InfoObject or from one item to another while in modeling I always get this message " Reading Data " or "constructing workbench" in it runs for minutes.... anyway to stop this?
Q) Can any one give me info on how the BW delta works also would like to know about 'before image and after image' am currently in a BW project and have to write start routines for delta load.
Q) I am very new to BW. I would like to clarify a doubt regarding Delta extractor. If I am correct, by using delta extractors the data that has already been scheduled will not be uploaded again. Say for a specific scenario, Sales. Now I have uploaded all the sales order created till yesterday into the cube. Now say I make changes to any of the open record, which was already uploaded. Now what happens when I schedule it again? Will the same record be uploaded again with the changes or will the changes get affected to the previous record.
A)
Q) In BW we need to write abap routines. I wish to know when and what type of abap routines we got to write. Also, are these routines written in update rules? I will be glad, if this is clarified with real-time scenarios and few examples?
A) Over here we write our routines in the start routines in the update rules or in the transfer structure (you can choose between writing them in the start routines or directly behind the different characteristics. In the transfer structure you just click on the yellow triangle behind a characteristic and choose "routine". In the update rules you can choose "start routine" or click on the triangle with the green square behind an individual characteristic. Usually we only use start routine when it does not concern one single characteristic (for example when you have to read the same table for 4 characteristics). I hope this helps.
We used ABAP Routines for example:
To convert to Uppercase (transfer structure)
To convert Values out of a third party tool with different keys into the same keys as our SAP System uses (transfer structure)
To select only a part of the data for from an infosource updating the InfoCube (Start Routine) etc.
Q) What is ODS?
A) An ODS object acts as a storage location for consolidated and cleaned-up transaction data (transaction data or master data, for example) on the document (atomic) level.
This data can be evaluated using a BEx query.
Standard ODS Object
Transactional ODS object:
The data is immediately available here for reporting. For implementation, compare with the Transactional ODS Object.
A transactional ODS object differs from a standard ODS object in the way it prepares data. In a standard ODS object, data is stored in different versions ((new) delta, active, (change log) modified), where as a transactional ODS object contains the data in a single version. Therefore, data is stored in precisely the same form in which it was written to the transactional ODS object by the application. In BW, you can use a transaction ODS object as a data target for an analysis process.
The transactional ODS object is also required by diverse applications, such as SAP Strategic Enterprise Management (SEM) for example, as well as other external applications.
Transactional ODS objects allow data to be available quickly. The data from this kind of ODS object is accessed transactionally, that is, data is written to the ODS object (possibly by several users at the same time) and reread as soon as possible.
It offers no replacement for the standard ODS object. Instead, an additio -
KEU5 – It does not found senders (emisor) for segment.
Dear Expert Sap
Please, I try to explain the following scenary :
I had created one purcharse using ME21N transaction, that it had one service and imputation on cost center (CeCo)
I had created document using ML81N and accepting.
I can lookup posting document FI and it is correct.
I can lookup posting document profit center cost
But it did not create posting on COPA. Because It did not have configuration or specified OKB9: Cost Ctr (KSTAR) assigned - > Cost element master (KOSTL).
When I am excuting this report S_ALR_87013611 - Cost Centers: Actual/Plan/Variance.
I are seing income as statistical posting under cost centres.
Cost centres cannot have 'real' income postings. It is correct.
Because Cost Ele category is equal “12” and (Cost Ele category 11 or 12) are posted AS statistical on cost centers.
Finally:
Bussines need that "posted as statistical on cost centers" => it should create on COPA.
We are thinking that we can using a cycle in KEU5 transacction.
But whem we are executing transaction KEU5 son it get this message:
– It does not found senders (emisor) for segment.
Unfortunately, I am not found one note oss.
Could you check this and recommend the best option? or could you recommend any note oss, please?
All your recomendations will be welcome.
Thanks a lot for your recomendation and help.
Best regards,
Gustavo HermozaThank you very much for your answer, Ronghua!!!
I am thinking about your recomendation about using substitucion (OKC9) to derivate the PAOBJNR as reael account assignment.
It will probably be good idea but Step(Okc9) does not derivate or move characteristics to RKE_GET_ACCTNR Function. Because we dont not know this characteristics.
We had reviwed cost line items for cost center and we are seeing that all document are Material Document and this document dont have fields to derivate characteristics.
Another alternative:
Transaction KA02 change category element.
Field change CElem Category is not possible (transaction data already exists)
Diagnosis
To ensure the consistency of existing data, you can only change object CElem Category if no transaction data exists in the change period; that is, neither plan data nor actual data has been posted.
As transaction data already exists, it is not possible to change objects in this time period.
Procedure
If you still want to change the object, select a suitable change interval by choosing "Edit -> Analysis period...".
I want to show this post it is good.
Profitability segment - ERP SD - SCN Wiki
Thanks a lot for your recomendation and help.
Best regards,
Gustavo Hermoza
Maybe you are looking for
-
My positive experience with FCPX.
In an effort to present the other side of the coin on this forum, that FCPX can work very well, here is my story. For the last 8 years I've been using Final Cut Express on an older Macs. It worked fine for my various projects, although the incessant
-
How can I generate a map file with LabVIEW?
We wish to use a product which inserts code into our executable to prevent tampering with it by crackers. The program, however, takes the executable file, as well as the map file (which is commonly generated by c++ compilers) and uses the map file t
-
Firefox will not load any websites at all
I have been using Firefox for more than awhile, as IE 10 would not work for me, but a few days ago Firefox stopped working all together. I will click Firefox and all that happens is it loads a New Tab, and it has a blank page with no web address. If
-
Bonjour , j ai un probleme avec mon port mini display , j ai brancher mon adaptateur mini display port pour hdmi sur mon mac et raccordé ma tv philips 119 cm recente avec un cable hdmi 1.4 qui fonctionne sur mon autre pc, et rien ne se passe. Dans le
-
Hello my name is Ian. I have 23 numbered pdf docs. I want to merge into one and have them list in order. I have Adobe Export pdf. Thank you for any help. Ian