Analysis Engine Not running

When i do "sh ver" over an IDS 4250XL 5.1(1)S243.0 it appears:
AnalysisEngine 2006_Feb_08_13.09 (Release) 2006-02-08T13:52:38-0600 NotRunning
What does it imply? How can i start it?
Thanks,

If the ananlysis engine is not running, your sensor is not analyzing dumped traffic (and is therefore useless).... To get it started, follow the steps below.
1. Create a service account user in CLI or IDM
2. Login using service account in CLI
3. Switch to root user by typing su and service account pwd
4. Type the following command at bash-2.05b# prompt: /etc/init.d/cids restart
5. To check if the sensor is "up" again, type su cisco. Then do a show version.
6. If you still experience issues, exit back to the service account and type reboot.
If the helps, please rate me..
Cheers,
Jay Walker

Similar Messages

  • Analysis Engine Not running for IPS in AIPSSM Module

    Hi all,
      The Analysis Engine is not running for IPS module in AIPSSM Module. Please let me know how can i resolve this issue and get the analysis engine of IPS to running status.
    Regards
    Kiran

    Hi Kiran,
    Ideally, what you can do is to remove the configuration on the ASA that sends traffic to IPS.
    The crash in sensorapp or analysis engine might be traffic, configuration related.
    We can try to reboot the IPS with no load on it by stopping sending traffic to it.
    You can remove the IPS policy from the ASA configuration.
    http://tools.cisco.com/squish/2f7A3
    What this will do is stop ASA from sending any traffic to IPS.
    Now do the hw-module module 1 reset command.
    See if the IPS module comes back up.
    If that also fails, then you can re-image the module.
    This will however erase the configuration on the module.
    The re-image procedure for SSM module:
    http://tools.cisco.com/squish/ee66a
    Hope this helps.
    Sid

  • Cisco ips 4206 Analysis Engine not running

    Cisco IPS 4206
    AnalysisEngine     BE-BEAU_E4_2010_MAR_25_02_09_7_0_2   (Ipsbuild)   2010-03-25T02:11:05-0500   NotRunning  
    Sensor health is showing critical .
    Application showing failed .
    Can any body help me on this,.

    We have had this issue in the past with our sensors and the only way that we were able to clear it was with a reboot of the sensor.  If you decide to reboot then you should probably do a "show tech" before the reboot and open a case with support to see what the root cause of the issue was.

  • ASA-SSC-AIP-5 Analysis Engine Not Responding

    Every couple of days I have been noticing that the IPS is in bypass mode and the Analysis Engine Status is often shown as not responding or is still loading something, and naturally, the CPU is pegged at 100%... so I have been reloading the IPS when this happens.
    2 Questions:
    Any general pointers of what often causes this, or things that I should look for when this is happening?  I know I did not give enough details for specific answers, but I am just looking for general ideas to start with.
    More importantly, what syslog messages might show up in the logs when the IPS goes into Bypass mode?  I'd like to setup a notification for these syslog messages so that I can troubleshoot immediately and determine the cause.
    IPS Version 6.2(2)E4
    Signature Version 559.0
    Cisco Adaptive Security Appliance Software Version 8.3(2)13
    Thanks.

    I would suggest that you upgrade the AIP-5 software to the latest version: 6.2.3(E4).
    Here is the release notes where a number of memory related bugs have been resolved:
    http://www.cisco.com/web/software/282549758/38029/IPS-6_2-3-E4_readme.txt
    You might also want to check if the AIP-5 module is overloaded with traffic, which can cause that issue.

  • 4215 IPS 5.x analysis engine woes

    I've got about 20 4215's that i'm upgrading from 4.1 to 5.x
    Like everyone else I've had nothing but problems with the 5.1x (analysis engine just stops running)
    I've tried upgrading using a brand new image, using both the 5.0(1) and 5.0(2) images. However, with both of those I get the following errors:
    Modify virtual sensor "vs0" configuration?[no]: yes
    Warning: The AnalysisEngine is initializing, virtual-sensor "vs0" can not be configured.
    and..
    sensor# conf t
    sensor(config)# serv analysis-engine
    sensor(config-ana)# virtual-sensor vs0
    sensor(config-ana-vir)# physical-interface fast
    fastEthernet0/0 fastEthernet1/0 fastEthernet1/2
    fastEthernet0/1 fastEthernet1/1 fastEthernet1/3
    sensor(config-ana-vir)# physical-interface fastEthernet1/3
    sensor(config-ana-vir)# ex
    sensor(config-ana)# ex
    Apply Changes:?[yes]:
    Error: editConfigDeltaAnalysisEngine : Analysis Engine is busy
    What's the deal with this? It sometimes takes several resets just to work. Sometimes I have to wait 10 minutes. Sometimes it just doesn't work at all. I can't even upgrade to 5.0(6) or anything because, you guessed it, my analysis engine is busy.
    Does it normally take that long for it to allow me to make changes? Anybody have any ideas?

    After a re-image there will always be a period of time when the Analysis Engine is busy.
    The Analysis Engine can take up to about 30 minutes on a low end sensor like the IDS-4215 to completely initialize itself.
    It takes all of the regular expression signatures and will compile the regular expressions together into what you can consider one giant regular expression. It was what we call a regular expression cache file.
    The creation of the regular expression cache file was speeded up as part of a bug fix in the 5.0(6) Service Pack.
    So what to do:
    After you do a re-image of the sensor just let it sit for 20 to 30 minutes. Then execute "iplog-status". If it tells you analaysisEngine is busy then keep waiting. It is tells you No Ip Logs are available then it is ready to go. (Any other command that queries the AnalysisEngine would work as well) This way you can also check the Analysis Engine status before going through and typing up all of the config changes.
    Resetting the sensor while the Analsysis Engine is busy just prolongs the initialization, the Analysis Engine will have to redo some of the intialization.
    My recommendation for versions right now is to load 5.0(1) or 5.0(2) base image. Wait for 20 to 30 minutes till Analysis Engine is responding, then load the 5.0(6) Service Pack. When you load the 5.0(6) Service Pack there will once again be a big jump in signatures so there will be another initialization period.
    Once that initialization is done, then load the latest Signature Update.
    As for version 5.1(1) there are some known issues that cause Analysis Engine to stop Running. Don't confuse these bugs with the standard initialization time for Analysis Engine. Analysis Engine veing busy is normal and expected after a re-image or upgrade, an Analysis Engine "Not Running" is a bug.
    If you are seeing "Not Running" for Analysis Engine when executing "show version" then please contact the TAC. There is a engineering patch for some of these issues, but it does requiring running special engineering builds that are in the process of going through testing.
    Cisco is working on these issues and will be releasing an official update as soon as the fixes have been fully tested at Cisco.
    Until those 5.1(1) issues are addressed, your options would be to contact the TAC and possibly obtain the special engineering build, or downgrade to the 5.0(6) version as mentioned above.

  • Restarting Analysis Engine on IDSM-2

    Hi All,
    I have an IDSM-2 module and I have noticed that the analysis engine stops very frequently (I do a show version and I see the analisys engine not running). Is there a way to restart it without reseting the module?
    I also see the following message:
    Note: /etc/modules.conf is more recent than /lib/modules/2.4.30-IDS-smp-bigphys/modules.dep
    does anybody know what does it mean?
    Regards

    Hi Vicente,
    The work around was to disable auto-update, sigs 3333 and 5597 (SMB MSRPC Messenger Overflow). I have no idea why this was the work around but it seems to have worked. They are also supposed to have a minor version upgrade on Monday that fixes this issue I just found out.
    Cheers

  • Analysis Engine is Not Running

    Hi Guys!
    I´m looking for your help about an issue with an Cisco IPS (B-BEAU) that is showing the Analysis Engine=NotRunning
    These are the SO and Version of my IPS:
    Version: 7.0(6)E4
    OS Version: 2.4.30-IDS-smp-bigphys
    If I execute the show events command I get the following lines:
    ct-sensorApp.650 not responding
    evStatus: eventId=1326914865100530240 vendor=Cisco
      originator:
        hostId: XXXXXXXX
        appName: modprobe
        appInstanceId:
      time: 2013/07/13 02:11:05 2013/07/12 20:11:05 CST
      syslogMessage:
        description: Note: /etc/modules.conf is more recent than /lib/modules/2.4.30-IDS-smp-bigphys/modules.dep
    The following lines show the result for the show status command:
    XXXXXX# show health
    Overall Health Status                                   Red
    Health Status for Failed Applications                   Red
    Health Status for Signature Updates                     Not Enabled
    Health Status for License Key Expiration                Red
    Health Status for Running in Bypass Mode                Red
    Health Status for Interfaces Being Down                 Red
    Health Status for the Inspection Load                   Green
    Health Status for the Time Since Last Event Retrieval   Not Enabled
    Health Status for the Number of Missed Packets          Green
    Health Status for the Memory Usage                      Not Enabled
    Health Status for Global Correlation                    Not Enabled
    Health Status for Network Participation                 Not Enabled
    Security Status for Virtual Sensor vs0   Green
    Security Status for Virtual Sensor vs1   Green
    Do you have any idea what's wrong here?
    I'll appreciate any help about it,
    Thanks folks!!!

    Hi Manuel,
    Pre-7.0.8 versions have issues with the latest signature updates, so most likely you will face this issue after every signature upgrade. So I suggest you to upgrade at least to 7.0.8 or 7.1.7.
    HTH
    Luis Silva
    "If you need PDI (Planning, Design, Implement) assistance feel free to reach"
    http://www.cisco.com/web/partners/tools/pdihd.html

  • Analysis Enginer showing not running

    Analysis Engine is not running and giving Error:
    Error: getAnalysisEngineStatistics : ct-sensorApp.598 not responding, please check system processes - The connect to the specified Io::ClientPipe failed

    I fixed this issue once using the following procedure:
    https://supportforums.cisco.com/docs/DOC-3589
    If the above procedure or reload does not fix the issue as suggested on the following link:
    https://supportforums.cisco.com/docs/DOC-5121/diff;jsessionid=82FA4EB3696EC0C97B6394F996EEAA5E.node0?secondVersionNumber=2
    You have to contact TAC, as mentioned below:
    http://www.cisco.com/en/US/docs/security/ips/6.0/installation/guide/hwTS.html#wp1122031
    Regards
    Farrukh
    Message was edited by: Farrukh Haroon

  • CCADStatus.jsp not showing up (Analysis Engine Daemon Manager)

    We are in GRC5.3 SPS19 and I have configured our system as per the note 999785.  I am able to see the http://<server>:<port>/sap/CCBgStatus.jsp, I am seeing that the job is being run, but when I try "http://<server>:<port>/sap/CCADStatus.jsp" while I am not getting other than the heading "Analysis Engine Daemon Manager"
    Heap is already at 2048M as per the note 999785. Can somebody advise what needs tobe checked.

    Hi,
    try note 1176262 - Analysis Daemon Page is Blank/ BG Jobs stay in ready status.
    /Vit

  • FR and Web Analysis reports will not run in workspace

    I have configured both FR and Web Analysis and then re-configured workspace to pick them up. 'Reporting and Analysis shows up in my foundation metadata under workspace. All my related ports are enabled.
    Database connection manager, import financial reporting reports, preferences financial reporting, tools/link to web analysis, do not appear in workspace.
    get 'required application context analyzer is missing. please contact your adminstrator.' error when try to run a web analysis or financial reporting report from workspace.
    Web analysis as a client with reports is working fine.
    Financial reporting allows me to create a database connection, create a report, pdf preview from the client but web preview breaks with generic page not found error.
    Any suggestions would be most appreciated.

    Hi,
    You can use panel while creating reports and put all the graphs on it .
    Panels color can be changed.
    Thanks
    Yashwant

  • SAP j2ee engine is not running error while applying patches.

    Hi all,
    Iam in the process of aplpying patches using JSPM tool , for some of them iam getting the error messages , when i checked the log file for this tool it says:
    SAP J2ee engine is not running , unable to login to  <HOST name> with id <Login id>.
    Iam very new to this activity ,can anybody help me in this regard , i wil be very thankful.
    Thanks and Regards.
    Niyati.

    Hi,
    What exactly do you see when you say that the status in the MMC is OK? I don't think it can be green if you say that you get a message saying "Service Unavailable" when you try to login. If you get that message, it means that the service hasn't either been started or could not be started in case of an error. In this case the server status in the MMC should be yellow (or gray in case none of the services could be started)...
    Could you perhaps check it again? Another point to check would be if the connection to the database is OK. If you are using MySQL MaxDB, you could use the Database Manager tool to check this. Sometimes the log files fill up the database and the server cannot start because the database is full. In such cases you will need to clear the logs and then restart the entire cluster.
    Sameer

  • J2EE Engine is not Running

    Hi All:
    I start my XI server and found the J2EE Engine is not running what will be the main cause of this?? I tried to open the  Visula Admin but it is throwing an Error <i>Defult user parametes not find</i>
    What can be the cause of it??
    Thanks
    Farooq.

    Hi Farooq,
    For queries regarding user name and password, Please refer the page no 16 of the following pdf:
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/a0e1ba1a-e86e-2910-ee83-b73b54abc7d4
    I hope this helps.
    Regards,
    Shibani
    *Reward with points if helpful*

  • Critical Action and Role/Profile Analysis job in not running in GRC 5.3

    Hi Team,
    I  am working for a client where GRC 5.3 is installed( support pack 4 and patch 1).
    The installation is complete and also the post processing is done.
    We have scheduled a periodic ( weekly ) incremental background job for Critical Action and Role/Profile.
    Following are the parameter setting used:
    Task: Risk Analysis -Batch
    Batch Mode : Incremental
    First time it run successfully on 28th June'09 and it is completed with spool also. But next time it is supposed to run on 4th of July'09 . But it does not. And since then it is in same state.
    I am not able to find any reason that why it is behaving this way where other incremental jobs are running successfully.
    It will be helpfull if any one can guide me providing the solution.
    Regards,
    Kakali

    Hi Varun,
    I go to the Job History Button. It shows the following data only :
    2009-06-28 00:00:59 Done Job Completed successfully
    2009-06-27 23:45:00 Started RAR_PE1CLNT100_Critical Action and Role/Profile Analysis started :threadid: 0
    Under the Last Run Colomn it shows 28th June ( Status -completed)
    Under Next Run Date it is showing 4th July
    Follwoing are the list of Updates available From SP05
    When executing the critical roles/profile jobs in background, a message
    "error while executing the Job: null" comes up. ---( this one is for which come under Informer Tab)
    Background job spools are not available after upgrade from 5.2 to 5.3.
    Critical action and critical role/profile analysis cannot be run in
    background by system. --- ( But in my case It ran for once )
    Selection parameters (System, User and User Group) have been provided for
    "Critical Action and Role/Profile Analysis" in Configuration->Background
    Job->Schedule Job. --- ( it means it run usually)
    Critical Actions report in detail view shows no results after executing the
    Risk Analysis Job in the background. The same report shows data when
    executed in the foreground. ( this one is for which come under Informer Tab )
    When there is only one periodic job configured in RAR, this job fails to
    start after the first time in the specified time. ( this is not true, becoz there other periodic jobs running successfuly)
    Unable to run Informer - audit reports - critical role and profiles with
    logical systems. ( this is again under Informer Tab )
    I had gone through this  earlier also, but not able to match any update with my problem. If if have any other suggestion you can provide me the same.
    Is there any way to check for job log so that I can check what is the problem. View Log option is also greyed out as we have sap logger set up as a default logger Parameter. I have made it enable just to check but there is nothing.
    Please Guide.
    Regards,
    Kakali

  • Why do different versions of the LabVIEW Run-Time Engine not compatible?

    LabVIEW Run-Time Engine to become more and more big
    Why do different versions of the LabVIEW Run-Time Engine not compatible?
    " 一天到晚游泳的鱼"
    [email protected]
    我的个人网站:LabVIEW——北方客栈 http://www.labview365.com
    欢迎加入《LabVIEW编程思想》组——http://decibel.ni.com/content/groups/thinking-in-labview
    Solved!
    Go to Solution.

    jwdz wrote:
    LabVIEW2020 ....... ,it look like?
    You need to express your ideas more clearly. We cannot fill in the blanks and read between the lines if the post has no substance.
    jwdz wrote:
    It will affect the future development of LabVIEW, right?
    What is "it"?
    There are many things that affect the future development of LabVIEW, starting with NI management, all the smart people in LabVIEW development, the economy, the LabVIEW users, etc.
    If you are worried about the increasing size of the distribution, the good news is that the cost of data storage and data transmission has dropped much more dramatically. Even though newer versions are bigger due to great and welcome new features, the improvements in infrastructure have actually made the distribution and storage significantly easier over the years and will continue to do so. Trust me!
    Nobody wants to go back to a LabVIEW version that fits on a floppy disk!
    LabVIEW Champion . Do more with less code and in less time .

  • WAS SP9 SR1 ABAP+Java Add in installation , j2EE engine is not running

    I have completely installed SAP Netweaver SP9 SR1 WAS ABAP+JAVA addin and Installed XI completely. After few days j2EE engine stops running. I have applied the license after requesting from SAP Mareketplace and applied in WAS ABAP using SLICENSE transaction.
    Issue faced
    1. Tried to connect j2ee engine home page which is showing.
    Dispatcher is running but no server connected.
    Now I have removed the WAS J2EE installation and removed the client on which WAS j2EE engine installed. After doing this I tested the WAS ABAP which is running fine. Now I am again installing WAS Java addin. Which installed success fully and have seen the j2ee engine server page running.  But proceeding further to install JAVA Dialog instance I am facing folloing issues
    2. while installation step 8 and 9 as per SAP INSTANCE GUI .
    3. And J2EE engine is again stopping.
    Can any one help me to install J2ee dialog installation and resolving these issues.
    Anand Verma
    HCL technologies

    Hi Anand,
    J2EE Engine has a separate licensing mechanism. If the temporary license expires, the server will shut down every 30 minutes. You install a permanent license using Visual Administrator in service "Licensing Adapter".
    In any case, a look into the log files of the engine can provide further information. They are found at
    .../<SID>/<INSTANCE>/j2ee/cluster/server<n>/log
    Kind regards,
    Juergen Kremp

Maybe you are looking for

  • How to play wikipedia sound files (Ogg) in Safari 6.0.3?

    I'm pretty sure the answer to this one is that it can't be done, but just in case I've missed something in my web searching. I used to be able to play them under OSX 10.6.8. For instance, these sound files: http://en.wikipedia.org/wiki/Beethoven_symp

  • How can i fix start botton ? Every time i need to press more to work.

    How can i fix start botton ? Every time i need to press more to work.

  • Spinning Beach ball for 1 hour after Lion X installation, pls help

    I have the Spinning Beach ball for 1 hour after Lion X installation, pls help How long is it going to take? Using Mac Book Pro corei5 with all previous updates. Thanks

  • Vip configuration

    Hi, While configuring vip network configuration using vipca, i am getting one window that is "Network Interfaces" As i seen in so many cluster ware installations screen shorts there they got eth0 (public) and eth1 (private) in "This page displays sup

  • Notification of new email in sub-folders

    Dear all, I have created several rules for my inbox so that specific emails move into specific folders. The problem that I am having is that when Mail receives a new email fitting the rules, it makes the new message sound and then moves the email int