ANM, ACE module device type
I have a pair of ACE modules installed and maintained through ANM. We
started with ANM 2.X and recently upgraded to 3.0.
The ACE modules were running code A1(6.3) and are now on A2(2.3).
ANM is identifying the devices as Device Type ACE v1.0, and device types
seem to limit the features that ANM exposes for configuration.
The GUI does not expose the HTTP/SSL rewrite features in Expert mode, but I
can configure the devices in the CLI.
I have been unable to find an info on how devices are identified, or if they type
can be changed..
The exact module installed is a ACE20-MOD-K9. Can anyone shed some light
on if this is an 'ACE V1.0' and if not, how to convince ANM of the correct type?
Just a thought - when you upgraded did you change the default www user password on the ACEs? I remember the upgrade instructions instructing that this step was necessary to allow manipulation of the configuration via xml (which I believe the ANM tool requires to exercise its full functionality).
Similar Messages
-
Can not import ACE module to ANM
Hello,
Good day.
I recently facing an interesting problem.
We are running ANM 5.1.0 to manage our LB contexts, those contexts are configured on ACE20-MOD-K9 module which installed in Catalyst6500 switch. Our installation is like this, two ACE20-MOD-K9 modules installed into same Catalyst6513 different slots. And those two ACE modules serves different Data Halls, contexts configured on those modules are completely seperated, different VLAN, different subnet no relation at all.
I'm able to import the catalyst chassis into ANM and under Config>Guided Setup>Import Device>Modules, I'm able to see both ACE modules but only one module able to be imported, another one I can not even choose it. There are slightly difference those two modules show themselves in that page. The one I'm able to import shows exactly it's module type and version number but another one is showing someting strange.
Slot# Model Type Serial # State Version Description #VC
3 ACE20-MOD-K9 ACE v2.3 XXXXXX up A2(3.5) Application Control Engine Module 28
9 ACE20-MOD-K9 Module XXXXXX Not Imported ace2t_main_d Application Control Engine Module N/A <---problem module
Does any was facing samiliar problem?
ThanksI think I found something related to my issue.
In ANM operating Guidance,section"Importing ACE Modules after the Host Chassis has been Imported" mentioned some restriction. The module in slot 9 actually has samiliar situation, show module commands shows that Catalyst chassis doesn't really recognize the software version that might caused ANM not able to figure out if that module is supported or not so it makes a simple decision deny import. I will try to reboot that module see if we can fix this issue.
"Guidelines and Restrictions
ANM 3.0 and greater releases do not support the importing of an ACE module that contains an A1(6.x) software release or an ACE appliance that contains an A1(7.x) or A1(8.x) software release. If you attempt to import an ACE that supports one of these releases, ANM displays a message to instruct you that it failed to import the unrecognized ACE configuration and that device discovery failed.
However, if you perform an ANM upgrade (for example, from ANM 2.2 to ANM 3.0), and the earlier ANM release contained an inventory with an ACE module that supported the A1(6x) software release or an ACE appliance that supported the A1(7.x) or A1(8.x) software release, ANM 3.0 (and greater) allows the A1(x) software release to reside in the ANM database and will support operations for the release. ANM prevents a new import of an ACE module or ACE appliance that contains the unsupported software version.
We strongly recommend that you upgrade your ACE module or ACE appliance to a supported ACE software release, and that you instruct ANM to recognize the updated release. See the "Instructing ANM to Recognize an ACE Module Software Upgrade" section.
See the Supported Device Tables for the Cisco Application Networking Manager for a complete list of supported ACE module and ACE appliance software releases."
http://www.cisco.com/en/US/docs/app_ntwk_services/data_center_app_services/application_networking_manager/5.2/user/guide/UG_manage_devices.html -
We have a Custom built tool to manage our existing CSS boxes wherein we shutdown multiple Services at one single instance without affecting the entire VIP. The reason to do that is because of the following scenario. 10 Servers. Each server has multiple interfaces configured to support multiple websites thru IIS. Out of the 10 Web servers if we plan to remove one server for code upgrade/deployment, we take that server and shutdown all its configured services from the CSS using our tool.
I understand in ACE, the control is not at the Rserver level, but at the Server farm wherein you have all you servers configured for multiple ports. If I want to take a server (which is configured for multiple websites and multiple ports), I have to navigate to each server farm in the GUI (ANM) and then select the rserver one at a time..U know, it is time consuming..
Since ANM uses mysql to store the data collected from ACE module, is there a way we can create custom tools to achieve our requirement. If possible, Could you please provide us more information on the ACE/ANM Interaction and the options to customize ANM features?
I checked and found from CISCO Site that ANM 1.2 is the latest and only available Software package to Manage ACE in GUI environment. Do you have any other recommendations are products?you can do it from the CLI.
Each rserver is defined with just an ip address and you define the port when using the rserver in a serverfarm.
By de-activating the rserver in global, you de-activate it in all serverfarms it is being used.
This does not seem possible with ANM so.
If you don't like CLI, you could use XML commands.
Gilles. -
When will ANM support ACE module A2(3.0)?
Hello,
We are using ANM 2.2 to manage our ACE modules running A2(2.2). I would like to upgrade our ACE modules to version A2(3.0). It was released on 12/Oct/2009 but ANM 2.2 still does not support it (although it does support A2(1.6a) which was published on 20/Oct/2009, after A2(3.0)). And 2.2 seems to be the latest version of ANM.
When can we expect ANM to officially support ACE module A2(3.0)?
Regards,
Marc.anm 3.0 will support ACE A2(3.0).
The current schedule date for next anm release is jan 2010.
Gilles. -
HI Experts,
We had some issue with Datacentre ACE modules. Both primary and DR ACE modules got restarted in 16 hours difference.
Unfortunately Syslog was not configured on the ACE and local logging got cleared after restart.
The current IOS version is A2(3.2). The modules uptime was around 300 Days.
Here is the log from 6509 switch during the restart
Primary DC 6509-1 .
Jul 10 18:52:05.383 WAT: %SVCLC-5-FWTRUNK: Firewalled VLANs configured on trunks
.Jul 10 18:56:47.291 WAT: %SNMP-5-MODULETRAP: Module 9 [Down] Trap
Jul 10 18:56:47.127 WAT: %OIR-SP-3-PWRCYCLE: Card in module 9, is being power-cycled off (Reset - Module Reloaded During Download)
Jul 10 18:56:47.271 WAT: %C6KPWR-SP-4-DISABLED: power to module in slot 9 set off (Reset - Module Reloaded During Download)
Jul 10 18:57:00.951 WAT: %OIR-SP-3-PWRCYCLE: Card in module 9, is being power-cycled off (Module not responding to Keep Alive polling)
Jul 10 18:57:00.951 WAT: %C6KPWR-SP-4-DISABLED: power to module in slot 9 set off (Module not responding to Keep Alive polling)
Jul 10 19:01:57.172 WAT: %DIAG-SP-6-RUN_MINIMUM: Module 9: Running Minimal Diagnostics...
.Jul 10 19:01:59.256 WAT: %SNMP-5-MODULETRAP: Module 9 [Up] Trap
Jul 10 19:01:58.700 WAT: %DIAG-SP-6-DIAG_OK: Module 9: Passed Online Diagnostics
Jul 10 19:01:59.256 WAT: %OIR-SP-6-INSCARD: Card inserted in slot 9, interfaces are now online
.Jul 10 19:02:04.548 WAT: %SVCLC-5-FWTRUNK: Firewalled VLANs configured on trunks
DR DC 6509-1 .
Jul 11 09:42:05.759: %LINK-5-CHANGED: Interface TenGigabitEthernet9/1, changed state to administratively down .
Jul 11 09:42:05.763: %SNMP-5-MODULETRAP: Module 9 [Down] Trap
.Jul 11 09:42:05.763: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet9/1, changed state to down
Jul 11 09:42:05.599: %OIR-SP-3-PWRCYCLE: Card in module 9, is being power-cycled off (Reset - Module Reloaded During Download)
Jul 11 09:42:05.747: %C6KPWR-SP-4-DISABLED: power to module in slot 9 set off (Reset - Module Reloaded During Download)
Jul 11 09:42:05.767: %LINK-SP-5-CHANGED: Interface TenGigabitEthernet9/1, changed state to administratively down
Jul 11 09:42:05.771: %LINEPROTO-SP-5-UPDOWN: Line protocol on Interface TenGigabitEthernet9/1, changed state to down .
Jul 11 09:42:14.535: %SVCLC-5-SVCLCNTP: Could not update clock on the module 9, rc is -1
Jul 11 09:42:19.395: %OIR-SP-3-PWRCYCLE: Card in module 9, is being power-cycled off (Module not responding to Keep Alive polling)
Jul 11 09:42:19.395: %C6KPWR-SP-4-DISABLED: power to module in slot 9 set off (Module not responding to Keep Alive polling)
Jul 11 09:47:15.819: %DIAG-SP-6-RUN_MINIMUM: Module 9: Running Minimal Diagnostics... .
Jul 11 09:47:19.871: %MLS_RATE-4-DISABLING: The global switching mode is now 'truncated'. Disabling the Layer2 Rate Limiters. .
Jul 11 09:47:19.903: %SNMP-5-MODULETRAP: Module 9 [Up] Trap Jul 11 09:47:19.633: %DIAG-SP-6-DIAG_OK: Module 9: Passed Online Diagnostics Jul 11 09:47:19.905: %OIR-SP-6-INSCARD: Card inserted in slot 9, interfaces are now online .
Jul 11 09:47:21.079: %LINK-5-CHANGED: Interface TenGigabitEthernet9/1, changed state to administratively down
Jul 11 09:47:20.912: %LINK-SP-3-UPDOWN: Interface TenGigabitEthernet9/1, changed state to down
Jul 11 09:47:21.080: %LINK-SP-5-CHANGED: Interface TenGigabitEthernet9/1, changed state to administratively down
.Jul 11 09:47:25.039: %SVCLC-5-FWTRUNK: Firewalled VLANs configured on trunks
.Jul 11 09:47:25.047: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet9/1, changed state to up
Jul 11 09:47:24.520: %LINK-SP-3-UPDOWN: Interface TenGigabitEthernet9/1, changed state to down
Jul 11 09:47:25.056: %LINK-SP-3-UPDOWN: Interface TenGigabitEthernet9/1, changed state to up
Jul 11 09:47:25.060: %LINEPROTO-SP-5-UPDOWN: Line protocol on Interface TenGigabitEthernet9/1, changed state to up
Please let me did anyone face this issue before or is it any known BUG?HI All, Thanx for the help. Got the resaon from show version output.
last boot reason: NP 1 Failed : SRAM Parity Error Chan 3
Also got the TAC comment on SRAM party error
The SRAM parity error presented in the core file is not due to a software issue.
The issue is the result of a "bit-flip" within the SRAM itself which can occur as a
result of environmental conditions. This "bit-flip" is rectified by a simple reboot of
the system, which would occur with the generation of the core file. Cisco internal
testing and customer experience has shown that these types of issues can occur
with very low frequency, but do not required an RMA of the device.
If there are multiple instances of this issue on the same module, a proactive RMA/EFA
of the device would be in order.
ACE is susceptible to this because of the way it uses SRAM to store control information
and packet data as opposed to scratch-pad storage. Almost any 1-bit flip will be detected as a
parity error. Cisco has recognized the issue and is taking action to ensure this will not be
an issue on the next generation of the ACE module. The next generation module design
and timeline is currently under review.
Thnx again for the help
Aslam -
ACE30 - Accessing the ACE Applicance Device Manager
Hi...
I've got basic connectivty to our ACE30 module and when I try connecting to the management IP address (attached to the Admin context), I see a very basic GUI which only lists the CSM to ACE config conversion tool. I don't see a GUI as detailed in the document:
http://www.cisco.com/en/US/docs/app_ntwk_services/data_center_app_services/ace_appliances/vA1_7_/configuration/device_manager/guide/UG_over.html#wp1072950
How do I get the ACE Applicance Device Manager GUI working so that I can then configure real servers, serverfarms etc rather than via the GUI?
Having read through copious amount of documentation I can't seem to find a refrence that would help here. This should be a fairly straight forward exercise - do I need to install some other software to get the full fledged GUI working?
thanks
SheldonOnly the ACE 4710 appliances have the GUI. If you are looking for a GUI for the ACE30 module you will need to use Cisco Application Network Manager (ANM) It will provide the GUI for the ACE30 to be able to configure it. As you have seen, only the conversion tool is available on the module.
-
How to Virtual IP configuration in ACE module?
Hi,
I am in the process of configuring load balancing on ACE module but struggling to configure virtual IP address for ACE module.
I'm working on ACE30 module and using software version A5 (1.2). ACE module is in slot of Catalyst 6504 switch.
Can anybody please post the steps/commands to perform this activity? An early response would be appreciated.
Regards,
Rachit.Hi Rachit,
Here is a basic configuration example:
access-list Allow_Access line 10 extended permit ip any any
rserver host test
ip address 10.198.16.98
inservice
rserver host test2
ip address 10.198.16.93
inservice
serverfarm host test
rserver test 80
inservice
rserver test2 80
inservice
sticky http-cookie test group2
cookie insert
serverfarm test
class-map match-all VIP
2 match virtual-address 10.198.16.122 tcp eq www
policy-map type loadbalance first-match test
class class-default
sticky-serverfarm group1
policy-map multi-match clients
class VIP
loadbalance vip inservice
loadbalance policy test
loadbalance vip icmp-reply active
nat dynamic 1 vlan 112
interface vlan 112
ip address 10.198.16.91 255.255.255.192
access-group input Allow_Access
nat-pool 1 10.198.16.122 10.198.16.122 netmask 255.255.255.192 pat
service-policy input NSS_MGMT
service-policy input clients
no shutdown
ip route 0.0.0.0 0.0.0.0 10.198.16.65
Here is the configuration guide:
http://tools.cisco.com/squish/101AD
Cesar R -
hi,
Is it possible to load balance VIP hits on two ACE Modules in an active/active configuration. Or is it that only per FT group only single context could be active.
Regards.You can have 1 context active on one ACE and the other context active on the other ACE.
If you have 2 Vip, you can have 1 vip belonging to one context and the other vip belonging to the other context.
Like this, you split the traffic between the 2 devices which allows you to handle more traffic than what 1 device could normally do.
If one device can handle all your traffic, I prefer to only have 1 active unit and 1 standby.
Easier to implement and troubleshoot.
Gilles. -
Reuse of context in ACE module
Hi all, just have a question about som reuse of resources in a ACE module context. I don't want to make a new context, and can reuse most of the existing configuration in one of my context. The config is not complex and difficult, but I'm not sure if I can do this.
The primary goal is to loadbalance 2 webservers with a new vip, new serverfarm, stickygroup, policy-map and different nat-pool.
Since I haven't decided the ip addresses to be used, they are just xx in the config below.
The changes I want to implement are in bold. Will this work for me?
probe http WEBGUI_D2
description Probe for http mot webgui
interval 10
passdetect interval 10
passdetect count 1
request method get url /D2/auth/login.aspx
expect status 200 302
header User-Agent header-value "IDENTITY"
rserver host cwi003
description content server logon
ip address 10.163.22.27
inservice
rserver host cwi004
description content server logon
ip address 10.163.22.28
inservice
rserver host cwi503
description content server logon 2
ip address 10.163.22.23
inservice
rserver host cwi504
description content server logon 2
ip address 10.163.22.24
inservice
serverfarm host SF_LOGON_D2
probe WEBGUI_D2
rserver cwi003 80
inservice
rserver cwi004 80
inservice
serverfarm host SF_LOGON2_D2
probe WEBGUI_D2
rserver cwi503 80
inservice
rserver cwi504 80
inservice
sticky ip-netmask 255.255.255.255 address source STICKYGROUP1
timeout 20
replicate sticky
serverfarm SF_LOGON_D2
serverfarm SF_LOGON2_D2
class-map match-all VS_LOGON_D2
3 match virtual-address 10.163.22.13 any
class-map match-all VS_LOGON2_D2
3 match virtual-address 10.163.22.xx any
policy-map type loadbalance first-match PM_ONE_ARM_LB
class class-default
sticky-serverfarm STICKYGROUP1
policy-map multi-match PM_ONE_ARM_MULTI_MATCH
class VS_LOGON_D2
loadbalance vip inservice
loadbalance policy PM_ONE_ARM_LB
nat dynamic 5 vlan 1240
class VS_LOGON2_D2
loadbalance vip inservice
loadbalance policy PM_ONE_ARM_LB
nat dynamic 6 vlan 1240
interface vlan 1240
description Client_server
ip address 10.163.22.11 255.255.255.0
peer ip address 10.163.22.12 255.255.255.0
access-group input INBOUND
nat-pool 5 10.163.22.14 10.163.22.17 netmask 255.255.255.192 pat
nat-pool 6 10.163.22.xx 10.163.22.xx netmask 255.255.255.192 pat
service-policy input PM_ONE_ARM_MULTI_MATCH
no shutdown
ip route 0.0.0.0 0.0.0.0 10.163.22.1
BR
GeirThanks for your reply.
Hope I understand you correct. This sould be the config I need to paste into the existing context.
rserver host cwi503
description content server logon 2
ip address 10.163.22.23
inservice
rserver host cwi504
description content server logon 2
ip address 10.163.22.24
inservice
serverfarm host SF_LOGON2_D2
probe WEBGUI_D2
rserver cwi503 80
inservice
rserver cwi504 80
inservice
sticky ip-netmask 255.255.255.255 address source STICKYGROUP2
timeout 20
replicate sticky
serverfarm SF_LOGON2_D2
class-map match-all VS_LOGON2_D2
3 match virtual-address 10.163.22.xx any
policy-map type loadbalance first-match PM_ONE_ARM_LB2
class class-default
sticky-serverfarm STICKYGROUP2
policy-map multi-match PM_ONE_ARM_MULTI_MATCH
class VS_LOGON2_D2
loadbalance vip inservice
loadbalance policy PM_ONE_ARM_LB2
nat dynamic 6 vlan 1240
interface vlan 1240
nat-pool 6 10.163.22.xx 10.163.22.xx netmask 255.255.255.192 pat
Br
Geir -
Ace module in bridged mode with client nat
Could someone confirm whatever a NAT is supported for ACE-20 module, please?
Let me to explain technical details.
I do need to convert working CSM(SLB) config to ACE configuration and I am not quite sure
if the configuration below is correct. ACE module should be configured in bridge mode with two
vlans - vlan 36 (client) and vlan 436 (server) - bridged with interface bvi 36.
NAT on ACE configurad as "nat dynamic 1025 vlan 436" into corresponding
"policy-map type loadbalance"
Could you check two parts of configs and advise me if the ACE config is
properly converted from CSM and will be working in the same way (especialy for NAT).
Thank you in advance.
CSM config
=======
vlan 36 client
ip address 10.36.3.3 255.255.255.0 alt 10.36.3.4 255.255.255.0
gateway 10.36.3.1
vlan 436 server
ip address 10.36.3.3 255.255.255.0 alt 10.36.3.4 255.255.255.0
natpool WEB-MAIL 10.36.3.100 10.36.3.100 netmask 255.255.255.0
sticky 30 netmask 255.255.255.255 address source timeout 60
probe SHAREPOINT tcp
interval 30
failed 120
open 3
port 80
probe WEBMAIL-443 tcp
interval 5
failed 60
open 2
port 443
serverfarm WEBMAIL-443
nat server
nat client WEB-MAIL
predictor leastconns
real 10.36.3.101 443
inservice
real 10.36.3.102 443
inservice
probe WEBMAIL-443
serverfarm WEBMAIL-80
nat server
nat client WEB-MAIL
predictor leastconns
real 10.36.3.101 80
inservice
real 10.36.3.102 80
inservice
probe SHAREPOINT
vserver WEBMAIL-443
virtual 10.36.3.100 tcp https
serverfarm WEBMAIL-443
sticky 60 group 30
replicate csrp sticky
replicate csrp connection
persistent rebalance
inservice
vserver WEBMAIL-80
virtual 10.36.3.100 tcp www
serverfarm WEBMAIL-80
replicate csrp connection
persistent rebalance
inservice
ACE config
=======
probe tcp WEBMAIL-443
interval 5
open 2
passdetect interval 60
port 443
probe tcp SHAREPOINT
interval 30
open 3
passdetect interval 120
port 80
serverfarm host WEBMAIL-443
predictor leastconns
probe WEBMAIL-443
rserver 10-36-3-101 443
inservice
rserver 10-36-3-102 443
inservice
serverfarm host WEBMAIL-80
predictor leastconns
probe SHAREPOINT
rserver 10-36-3-101 80
inservice
rserver 10-36-3-102 80
inservice
class-map match-all WEBMAIL-80
match virtual-address 10.36.3.100 tcp eq www
class-map match-all WEBMAIL-443
match virtual-address 10.36.3.100 tcp eq https
sticky ip-netmask 255.255.255.255 address source 30
serverfarm WEBMAIL-443
replicate sticky
timeout 60
policy-map type loadbalance first-match WEBMAIL-80
class class-default
serverfarm WEBMAIL-80
nat dynamic 1025 vlan 436 serverfarm primary
policy-map type loadbalance first-match WEBMAIL-443
class class-default
sticky-serverfarm 30
nat dynamic 1025 vlan 436 serverfarm primary
parameter-map type http HTTP_ADV_OPT
persistence-rebalance
policy-map multi-match IFVLAN36-POLICY
class WEBMAIL-80
appl-parameter http advanced-options HTTP_ADV_OPT
loadbalance policy WEBMAIL-80
loadbalance vip inservice
loadbalance vip icmp-reply active
class WEBMAIL-443
appl-parameter http advanced-options HTTP_ADV_OPT
loadbalance policy WEBMAIL-443
loadbalance vip inservice
loadbalance vip icmp-reply active
interface vlan 36
bridge-group 36
service-policy input IFVLAN36-POLICY
mac-sticky enable
no shutdown
interface vlan 436
bridge-group 36
nat-pool 1025 10.36.3.100 10.36.3.100 netmask 255.255.255.0
no shutdown
interface bvi 36
ip address 10.36.3.3 255.255.255.0
peer ip address 10.36.3.4 255.255.255.0
no shutdownHello F.Makarenko-
You will want to use PAT while you do nat, so change the natpool configuration to this:
nat-pool 1025 10.36.3.100 10.36.3.100 netmask 255.255.255.0 pat
You also need to apply the nat like this:
policy-map multi-match IFVLAN36-POLICY
class WEBMAIL-80
appl-parameter http advanced-options HTTP_ADV_OPT
loadbalance policy WEBMAIL-80
loadbalance vip inservice
loadbalance vip icmp-reply active
nat dynamic 1025 vlan 436
class WEBMAIL-443
appl-parameter http advanced-options HTTP_ADV_OPT
loadbalance policy WEBMAIL-443
loadbalance vip inservice
loadbalance vip icmp-reply active
nat dynamic 1025 vlan 436
If you are going to build out a lot of classes, you can instead do source nat like this:
policy-map multi-match IFVLAN36-POLICY
class WEBMAIL-80
appl-parameter http advanced-options HTTP_ADV_OPT
loadbalance policy WEBMAIL-80
loadbalance vip inservice
loadbalance vip icmp-reply active
class WEBMAIL-443
appl-parameter http advanced-options HTTP_ADV_OPT
loadbalance policy WEBMAIL-443
loadbalance vip inservice
loadbalance vip icmp-reply active
class class-default
nat dynamic 1025 vlan 436
Regards,
Chris Higgins -
Hi,
I am trying to configure FT on ACE modules, with the following commands
ft interface vlan 20
ip address 172.16.20.1 255.255.255.252
peer ip address 172.16.20.2 255.255.255.252
no shutdown
ft peer 1
heartbeat interval 300
heartbeat count 10
ft-interface vlan 20
ft group 1
peer 1
priority 150
associate-context Admin
inservice
The moment I enter the command 'ft interface vlan 20', it gives a prompt that 'interface vlan20 is not associated with ft', how do I resolve this ? Do I need to enable something ?Hi have the following config which seems to be working fine for me... check your vlan20 interface is up
ft interface vlan 212
ip address 172.31.1.221 255.255.255.252
peer ip address 172.31.1.222 255.255.255.252
no shutdown
ft peer 1
heartbeat interval 300
heartbeat count 20
ft-interface vlan 212
ft group 2
peer 1
priority 50
peer priority 150
associate-context Admin
inservice
HQ-ACE1/Admin# sh int
vlan212 is up, administratively up
Hardware type is VLAN
MAC address is 00:23:5e:25:72:f1
Mode : routed
IP address is 172.31.1.221 netmask is 255.255.255.252
FT status is standby
Description:not set
MTU: 1500 bytes
Last cleared: never
Last Changed: Tue Sep 6 12:46:06 2011
No of transitions: 1
Alias IP address not set
Peer IP address is 172.31.1.222 Peer IP netmask is 255.255.255.252
Assigned from the Supervisor, up on Supervisor
8654909 unicast packets input, 735611030 bytes
1151150 multicast, 161 broadcast
0 input errors, 0 unknown, 0 ignored, 0 unicast RPF drops
13020418 unicast packets output, 1672055521 bytes
0 multicast, 163 broadcast
0 output errors, 0 ignored -
Simple SLB with the ACE Module
Hello,
i have some problems with a ACE module i am currently tesing.
I have a simple Serverfarm with two Servers.
But there seems to be some Problems with the Loadbalancing i not understand:
1) I use Round Robin, but the ACE seems to put me serval times to the same server. I notice this, because i have different content on both servers, also different URLs.
2) withz the show serverfarm statement the total connects do not increment.
switch/slb-c1# show serverfarm webfarm
serverfarm : webfarm, type: HOST
total rservers : 2
----------connections-----------
real weight state current total
---+---------------------+------+------------+----------+--------------------
rserver: web1
10.0.33.201:0 8 OPERATIONAL 0 0
rserver: web2
10.0.33.200:0 8 OPERATIONAL 0 0
switch/slb-c1# show service-policy L4_LB_VIP
Status : ACTIVE
Interface: vlan 300
service-policy: L4_LB_VIP
class: L4_VIP_CLASS
loadbalance:
L7 loadbalance policy: L7_SLB_POLICY
VIP Route Metric : 77
VIP Route Advertise : DISABLED
VIP ICMP Reply : ENABLED
VIP State: INSERVICE
curr conns : 0 , hit count : 15
dropped conns : 0
client pkt count : 10198 , client byte count: 420991
server pkt count : 23367 , server byte count: 34915173
I have attatched the Config.
Any Idea what is going on?what version do you have ?
I would recommend to run the very recent A1.4.
This is something that really should work.
Gilles. -
ACE Module Radius with ACS 4.2
Hi,
I am able to authenticate to my ACE modules via Radius, but when I login it does not give my Admin rights. Does anyone have a fix for this? My ACS admin has been working with TAC since last week to no avail.
John...You have to use a custom AV pair on TACACS server under user setup to make it work. ACE uses RBAC (role based Access Control) and for that you have to pass the context and User Role from Tacacs server to ACE to make it work.If there is no RBAC info is pushed from Tacacs server and user just get authenticated then the default role assigned by ACE is Network-Monitor.
Following steps (On tacacs server) will make it work
1. Select your user
2. goto tacas+ settings
3. Select " shell (exec)" checkbox
4. Select "custom attributes" checkbox
5. Type your context and role information in custom attrib box, using following format
shell:*
for e.g (if context name is Admin, domain is default-domain and you want to assign role "Admin" to this user )
shell:Admin*Admin default-domain
Hope it helps
Syed -
Convert_otf - Identify device type
Hi Experts
I am more of a functional consultant, so please excuse if this is simple thing to find out.
We are calling functional module CONVERT_OTF through a custom program to convert outputs of billing documents into a PDF file.However the PDF file generated has alignment and formatting issues. So we checked further and our ABAP consultant mentioned that the device type 'SCREEN' is used while converting the output into PDF format. This device type does not have any formats attached we we can see through transaction SPAD. So they feel this is the reason for incorrect format / misalignment of PDF output.
So we want to change the device type 'SCREEN' to 'WINSAP' which has all the required formats attached to it.
However our abaper does not not know when the program calls for device type and where to change it. He feels that output device type is called by standard FM CONVERT_OTF and we need to check with SAP on the same.
Therefore we need to know how we can change device type for this requirement.If someone has worked similar query, please help us to resolve this. Any pointers would be highly appreciated.
Regards,
SantoshHi Santosh,
If your requirement is to save the preview as PDF of the billing documents, you just need to type PDF! in the command field of the print preview screen and do a f8 then a pop will come up and then you can save or print the preview.
Note : you have to type PDF in Capitals and along with ! (exclamation mark symbol) i.e. PDF! .
Hope this helps.
BR
Dep
Edited by: DeepakNandikanti on Aug 16, 2011 8:57 PM -
Inventory collection fails for ACE module (RME 4.3.1)
I am trying to collect the inventory and ultimately the configurations for my ace modules. When i try to do an inventory collection I get the error
Device sensed, but collection failed
Anybody have any ideas?
ChrisPost your IC_Server.log.
Please support CSC Helps Haiti
https://supportforums.cisco.com/docs/DOC-8895
https://supportforums.cisco.com
Maybe you are looking for
-
Photo issue on iPhone 4 after iOS5 update
Since i have updated my White iPhone 4 to iOS5 some of my apps pictures dont appear just the text underneath them. I thought nothing of this at first as after a while they do appear but then others will dissapear! I tried to use the camera and i can
-
TCP Callback function passing data to teststand
Hi, I'm trying to pass data via a TCP Callback function to teststand using the TCP steptype that I downloaded from Ni. When I open a connection, container data is passed to the dll on which it creates a connection, the dll in part creates a TCP Callb
-
2nd gen Apple TV + External USB Hard Drive
My question is, Can i connect an external hard drive to the USB port of the AppleTV and play its content on TV? OR If i had a Time Capsule and put all my Videos and TV shows on it, could I play those on the AppleTV via wifi?
-
Incorrect domain name, switching to 'untrusted' :newbies here..
Starting emulator in execution mode Running with storage root DefaultColorPhone Incorrect domain name, switching to 'untrusted' java.lang.SecurityException: untrusted domain is not configured at com.sun.midp.security.Permissions.forDomain(+98) at com
-
Can't connect to internet on XP
I just created a Windows XP partition on my iMac, and I can't get the **** thing to connect to the internet now. I'm pretty sure the version of XP I installed is pre SP2 and 3. Can anyone help me figure out how to get connected to the internet on my