Hi Spring,
You can see your message at any stage in XI. This can be viewed with the help of Runtime WorkBench(RWB). A few options available in the Runtime Workbench are:
1. ADAPTER MONITORING This allows you to trace out the errors and problems occuring in your Adapters running on the j2ee engine.
2. END to END Monitoring This is similar to your SXMB_MONI and allows you to monitor the entire message flow.
3. PERFORMANCE MONITORING This is used to monitor the performance of your entire XI server.
Also, go through these links for further info,
https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/cbc7d790-0201-0010-bea6-c549902e93e2
http://help.sap.com/saphelp_nw04/helpdata/en/41/b715045ffc11d5b3ea0050da403d6a/content.htm
http://help.sap.com/saphelp_nw04/helpdata/en/96/0a2441509fa831e10000000a1550b0/content.htm
http://help.sap.com/saphelp_nw04/helpdata/en/5a/f72040599a8f5ce10000000a155106/content.htm
http://help.sap.com/saphelp_nw04/helpdata/en/25/9c2f3ffed33d67e10000000a114084/content.htm
Hope this helps.
Regards,
abhy
Similar Messages
-
After updating to Maverick on my Mac - unable to open numbers or pages docs on iPad or iPhone any suggestions or info?
I Just found it on the apple site, it arrived on a cd a few days later and worked just fine again.
i would recommend backing everything up just in case. Better safe than sorry, trust me. I've lost so much when i didnt back up once when re-installing the system.
IT shoulldnt erase everything, bt it might, so back up just in case
should you loose everything, then i have some tips on moving stuff fromyour iphone/ipod to the computer -
Messages on Holding at Message Monitoring under Runtime Workbench
Hello Colleagues,
we have currently the problem that a lot of messages for some interfaces are in status Holding under Message Monitoring at Runtime Workbench for PI 7.1.
I'm not able to resend the messages with status Holding as well as change status to cancel.
Quality of Service for the Interfaces are Exactly Once in Order.
I assume an error message blocks the queue and due to the fact we have Exactly Once in Order configured all following messages be in status Holding.
Is my assumption right?
But, I am not abel to find any messages in status error with blocks the queue!
How can I solve that issue?
Many thanks in advance!
JochenI assume an error message blocks the queue and due to the fact we have Exactly Once in Order
configured all following messages be in status Holding.
AE should have least number of EOIO messages at a given instance...otherwise Holding is what you get.....and holding is common with EOIO....so see if you can chagne the QoS of some messages to EO
But, I am not abel to find any messages in status error with blocks the queue!
Never you will get an error in SXMB_MONI....or the queue blocked....
When your message goes out of IE...the corresposding message entry is marked with chequered flag...observe in MONI you will see this....however in AE the message can fail if not able to send to the target system....
For some more understanding refer my answer in this thread:
Re: Restarting Error's in SXMB_MONI
Regards,
Abhishek. -
Error while opening Adapter Monitoring in Runtime Workbench
Hi,
I am unable to open Adapter Monitoring from
Runtime Workbench -> Component Monitoring -> Adapter Monitoring
When I tried to open, I am getting following message in the new window:
"The page cannot be displayed"
Please let me know where I can enable this option.
Thanks,
Yogi.Hi,
Go thru this SAP Note- 768456,928862
Also this doc may help u-https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/a0e1ba1a-e86e-2910-ee83-b73b54abc7d4
Regards,
Moorthy -
Problems after new installation (Runtime workbench not working as expected)
Hello
We have just finished installing new ECC & Netweaver in our company.
On PI side, I created a sample file (Payload) and did IR and ID configuration
and saw the payload getting picked up from the source directory and getting
posted in the target directory successfully.
However, when I went to Runtime Workbench and clicked on the Adapter and
File adapter to see the messages, I dont see anything. It is just blank.
However, when I click on Display it shows integration server and 4 items under it. 4th item is Adapter Engine which has a RED button next to it, indicating there is some problem.
When I click on the Adapter button to see the list of adapters, i see again a red button next JPR. However, File doesn't show any error message. But when I double click on File adapter, instead of showing successful messages, it shows a blank screen as if no file has been transmitted.
Also down at the bottom of the Runtime Work Bench Screen
Self-Tast Status and
Are Communication Channels without errors
also show a Red buttons next to it.
By double clicking on 'Are communication Channels without errors - Details", I get the following error message:
1 communication channels have an error status0 communication channels inactive0 communication channels not providing any status information0 adapters logging communication-channel-independent processing errors .
This is a fresh new install and any feedback on this will be greatly appreciated.
ThanksNot answered completely. But still closing to make room for new questions
-
Error in Runtime Workbench, Component Monitoring, Proxy Runtime
Hi,
I have the following error in the Runtime Workbench, under Component Monitoring->Integration Engines->Proxy Runtime. The error message is Ping Status: Unable to logon to system xxx in language EN with user XIRWBUSER. However, I am unable to find out where the account and password are specified in order to correct this. Any help would be appreciated.Hi,
it can be for some system configured on http destination or the sld system configured for this server.
take a look at tx sxmb_adm for the http destination to discover witch destination is been used. then, on sm59, find the server that is been called for this http destination and check on that server if this user is ok there.
to check sld, go to tx sld_apicust discover witch is the sld system configured for this server. After log on to sld system and check the user.
Maybe the user is ok on the destination system, so, check the password on sm59 (if the problem is with an http dest) or sld_apicust (if the problem is the connection to sld).
regards.
roberti -
SOAP Adapter + asynchronous message + Runtime Workbench
Hi
I have problem with error monitoring in Runtime Workbench -> Message Monitoring
I have SOAP adapter deployed on Apache Axis.
I have flow SOAP->XI->SOAP (asynchronous mode)
It works great until receiver adapter generate error.
I can see error message in defaultTrace log but in
Message Monitoring-> Details I see only "SOAP: response message
contains an error Application/UNKNOWN/APPLICATION_ERROR - application fault".
SOAP message from receiver adapter (with error) looks like that
<?xml version="1.0" encoding="UTF-8"?>
<soapenv:Envelope xmlns:soapenv="http://schemas.xmlsoap.org/soap/envelope/"
xmlns:xsd="http://www.w3.org/2001/XMLSchema"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<soapenv:Body>
<soapenv:Fault>
<faultcode>Client</faultcode>
<faultstring>Internal Server Error</faultstring>
<detail>
<myfaultmessage>
<type>RABAX_STATE</type>
<message>Divide by 0 (type 1).</message>
</myfaultmessage>
<ns1:hostname xmlns:ns1="http://xml.apache.org/axis/">pslupkowski</ns1:hostname>
</detail>
</soapenv:Fault>
</soapenv:Body>
</soapenv:Envelope>
I'm think that this message is not well formated and
Adapter Engine can't find some tags during parsing this
message. Any ideas how to solve this problem?
I'm just want to see error description from <myfaultmessage> tag in Message MonitoringHi,
Did you check the log on adapter engine?
http://<host>:<port>/MessagingSystem/monitor/monitor.jsp
Take a look to this monitor, here you can see both messages (request and response).
Cheers,
Ricardo. -
No "Adapter monitoring" in runtime workbench
We appear to having difficulties with our SOAP adapter in XI 3.0.
I have searched through the forum, and most queries relate to SOAP Adapter being greyed out in adapterframework, but it is not even available in the list.
We do no have the Adapter Monitoring as an option in our runtime workbench, either. How can we add this?
Any thoughts gratefully received!Hi Barry,
have you tried: http://server:port/mdt/amtServlet ?
this is the address of the adapter monitoring
the old address ( < sp4 as far as I remember) of the adapter monitor:
http://hostname:portnumber/AdapterFramework/monitor/monitor.jsp
regards,
michal
Message was edited by: Michal Krawczyk -
Messages are on HOLD in runtime workbench
Hi All,
I need your help. I don't know how to solve the following problem.
We have a message (idoc xml with a standard business document header from a gs1 xml) which will be send from a logical system in XI to another logical system in xi (same system).
The mapping is from one message - to more messages. This means one message comes in and dependent from the message two different message types could be go out (only one at one time). If the mapping is to one of these interface then it is also possible that one incoming message can create two or more output messages (same message type). And with this I have the problem. If more then one message is created in this mapping then this messages stay on hold in the runtime workbench. (If only one message is created, it is working fine). The QoS is for the messages "Exactly Once In Order" - thats what I see in the runtime workbench. The QoS in the sender communication channel is "Exactly Once".
Do you have any idea?
Thanks and regards
ManuelaHi Mathias,
thats the information in the rwb:
Attribute Value
Status Holding
Repeatable Yes
Cancelable Yes
Error Category
Error Code
Start 07.02.2008 10:46:59
End
Sender Party
Sender Service EU_GBO
Receiver Party
Receiver Service EU_GBO
Interface http://unilever.com/Xproc/ProcComm/GS1/ItmDtaNot/xi
Align_Item_Data_Notification_V2_1_ABS
Quality of Service Exactly Once in Order
Message 47aa17db-8e63-0158-0000-000091374080
Reference
Conversation ID MMFSERIALIZE0018
Version 0
Edited No
Serialization Context INBOUND_MMFSERIALIZE0018__
Direction INBOUND
Message Type Recv
Profile XI
Connection SOAP_http://sap.com/xi/XI/System
Transport HTTP
End Point http://ex1c002a:58300/MessagingSystem/receive/AFW/XI
Authorization
Sequential Number 105
Number of Retries 3
Failed 0
Retries 300000
Valid to
Persist Until 14.02.2008 10:46:59
Schedule Time 07.02.2008 10:46:59
2008-02-07 10:46:59 Success Processing child message of multi-message with message ID 47aa0c4f-ce91-0122-0000-000091374080
2008-02-07 10:46:59 Success Using connection SOAP_http://sap.com/xi/XI/System. Trying to put the message into the receive queue.
2008-02-07 10:46:59 Success Message successfully put into the queue.
2008-02-07 10:46:59 Success The message was successfully retrieved from the receive queue.
2008-02-07 10:46:59 Success The message status set to HOLD.
MMh external I think is not possible. Because it comes from a logical system in XI and goes from a logical system to XI. But on step before it comes from a SAP system. COuld it be there?
REgards
Manuela -
Communication channel doesn't show in runtime workbench
Hi,
In Integration monitoring Runtime Workbench does not show communication channel list in communication channel monitoring. It shows empty but we have created lot of communication channels. This is problem in XI adapter or any other problem? Please can anyone tell the solution for that.
Regards
VijayHi,
If ur searching for Xi and Receiver IDOC adapter in RWB.U cant find them in RWB then run in IS.try to check ur sender adapter and u can find the complete flow of it.
Thanks and Regards,
Phani Kumar -
Pls explain Runtime workbench and sxmb_moni
1)pls explain Runtime workbench and sxmb_moni.
Hi
The most important concepts:
sxmb_moni gives the errors of <b>ABAP Stack</b> i.e. I<b>ntegration Engine</b> errors.
RWB gives the errors of <b>Java Stack</b> i.e. <b>Adapter Engine</b> errors.
Rest check out these
https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/cbc7d790-0201-0010-bea6-c549902e93e2
http://help.sap.com/saphelp_nw04/helpdata/en/41/b715045ffc11d5b3ea0050da403d6a/content.htm
http://help.sap.com/saphelp_nw04/helpdata/en/96/0a2441509fa831e10000000a1550b0/content.htm
http://help.sap.com/saphelp_nw04/helpdata/en/5a/f72040599a8f5ce10000000a155106/content.htm
http://help.sap.com/saphelp_nw04/helpdata/en/25/9c2f3ffed33d67e10000000a114084/content.htm
https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/2f2a9fa2-0a01-0010-32ac-d281db722b86
Thanks -
Multiple message resend in Runtime workbench
hello experts,
Right now i m facing some problem to resend multiple messages at a time in the Runtime workbench.
If i get too many error message in Runtime workbench -> message monitoring then will anybody tell me that how i can send them at a time?
Please help me out in this case... because it is very difficult for my client to send messages one by one....
Thank you very much.
Regards,
Chaitanya.....Hey experts,
Thanx for quick replies... but the matter is i m getting error in data... so i will not be able to get that message in error into the SXMB_MONI.
Suppose i have 2 scenarios... 1 related to invoice and 1 related to orders... now the situation is like if order will be present into my receiver system then only it will accept invoice otherwise my invoice message will go into the error... this error i will get into the RWB only.
so suppose first my invoice message come and it went into the error in RWB... and then order message went into the receiver... so now without change i can resend the message and it will give into the reciever system.....
so if i have nearly 50-60 msg in error then if i want to resend it once how i can do?
Hey i hv already tried that multiple selection option but it is allowing me to select multiple messages but it is sending only one message at a time...
So number of times i have to press resend button.... so please tell me if any other settings are required....
Thanks in advance...
Regards,
Chaitanya............. -
Unable to send a test message (XML file) at the runtime workbench..
Hi,
we are not able to send a test message (XML file) at the runtime workbench just to test Idoc's. From the component monitoring, under the integration engine, test message- i have given all the parameters like sender and receiver service, interface namespace with the user id and password details. when i say send message it is throwing error while sending. not even displaying any error to attach here. I beleive it is a configuration problem in the integration directory. what do you reckon guys?
OS- win 2003 DB-Oracle 10.2.0.4
SAP PI 2004s basis SPS 18
Appreciate your much needed help!
Thx
SreeIt is a sender Idoc. we are using sender agreement and comm channel.
Why are you using a channel and agreement for IDOC....we dont need it when IDOC is sender!
All the channels and agreements (if created) are in XI/ PI and we can delete them if they are not required
Edited by: abhishek salvi on Mar 11, 2010 11:49 AM -
How can I define payload authorizations in Runtime Workbench?
Hi there,
I am trying to define JAVA-authorizations in our PI-landscape. My recent problem is that I am trying to give our developers the opportunity to read message payloads in the Runtime Workbench.
So far I have only been able to do this with administrator rights and this is no option. In the future I'd even have to distinguish between authorizations for different types of messages (according to namespaces et cetera) like you can do it in ABAP via the authorization object S_XMB_MONI, but first I'd like to at least assign payload authorizations without administrator rights.
Any ideas?
Regards
Mario>
Mario Marschall wrote:
> Now that's a little better as it at least deals with viewing authorizations. But as I said before, we've already accomplished that in the ABAP stack. Now I'd like to know how to do this in the Runtime Workbench, but I guess it's just not possible right now...
there is no configuration to be done in RWB.....however there is some in the VA (i.e. the JAVA stack)....check the note which i have provided in previous reply...
Regards,
ABhishek. -
Java.lang.NoClassDefFoundError in Runtime Workbench
Hello,
I am getting java.lang.NoClassDefFoundError: com/sap/aii/rwb/rtcheck/rtcserver/Processor error while trying to run Component Monitoring in runtime workbench.
Please advise!!
Thanks a lot
Edited by: Chanakya Sharma on Jun 13, 2010 9:47 AMDear Mark,
Thansk a lot. Even I was thinking on those lines.
But not sure, is their any way we can undeploy SP5 patch and come revert back to SP4?
I am facing one more issue in the following thread, I think it is also because of the same SP mismatch issue. Could you please have a look and post your expert comments there as well?
HTTP 500 Internal Server Error in SXMB_MONI
Thanks for support!!
Maybe you are looking for
-
IPTC information reverting to older version when opening in CS5
Ok, I will try to explain this as clearly as I can. I am having an issue with the IPTC information for an image (in this case keywords) reverting to a older version when I open the tiff image in photoshop CS6 compared to CS2. The keywords were added
-
CRM_ORDER_MAINTAIN - parameter data discarded - where is this happening?
Hello All, I'm having trouble with CRM_ORDER_MAINTAIN - many threads suggested break-pointing it while using the on-line transaction CRMD_ORDER and that has got me through a few problems. However it's not a possible strategy for a few remaining issu
-
Problems with certain websites
I have BB 8830 worldphone. I am having problems accessing certain websites. Have Verizon wireless as carrier. Using opera mini i cant log into a lot of credit card accounts or the verizon log on screens. What settings should I be using on my ph
-
How do I update to mac os x 10.6
how do I update to mac os x 10.6
-
Hi All, i've just bought an used x61 which is working fine, except the LEDs inside LCD cover. I replaced the inverter + LCD ribbon cable + BT module inside, but the only progress what i mention is that the ThinkLight LED is working fine and the Wifi