Dear PI Gurus,
I am kinda new to PI(XI) environment, and my self confused when I try to search failed messages in XI. I saw in Status group, there is Application Error, system Error and Error under SXMB_MONI. And I am wondering what is the different between these errors. Worst to come it all errors, Why we do have this separated errors? Can anyone tell me, what is the difference between this errors?
Thank You
Regards
Ramesh

Hi
- Application Error  related to SOAP
just look at tgis Blog
/people/jin.shin/blog/2007/05/21/handling-web-service-soap-fault-responses-in-sap-netweaver-xi
also look at this Thread  for SXMB_MONI-system error occured
SXMB_MONI-system error occured during persist
Regards
Abhishek
Edited by: Abhishek Agrahari on Jan 21, 2009 7:48 AM

Similar Messages

  • " SYSTEM ERROR" with ERROR CATEGORY: Message and ERROR ID : GENERAL

    HI all
    I m doing JDBC -> XI -> SOAP -> XI -> FILE ( XML) scenario .I have implemented it using  BPM .
    But ,In MONI , i am getting a "SYSTEM ERROR " with "ERROR CATEGORY : MESSAGE" and "ERROR ID : GENERAL" .and 
    One thing more is there my all adapters are active (JDBC,FILE) in runtime workbench but SOAP adapters i am not able to see it there as its services are not defined in there .Is this problem is because SOAP adapters are not defined in runtime workbench ?

    Hi Colin
    I are using SP 3.0
    I have checked the Communication channel monitoring and Adapter monitering also but in mine case when i want to see the SOAP adapter in adapter monitoring , the SOAP ICON is disabled there ,so i am not able to see whats the status of my SOAP adapter i have used in my scenario
    Thanks and Regards
    Abhishek

  • System Warning and Error Messages in Plant Maintenance

    Hi All,
    Where can I find the list of system warning and error messages for Plant Maintenance?
    Thanks
    Andrew

    Hi,
    Follow the following path in SPRO. Some of the standard messages you will fond there:
    Plant Maint & Customer Serivces - Maintenanace & Service Processing - Maint. & Service Orders - Message Control.
    SM

  • Creative Cloud Installation Failed Download Error - Error Type -7 and Error Code - 401

    I subscribed to Creative Cloud in December 2012 and have been trying to install the applications, but the "Installation Failed" through the Adobe Application Manager. (see screenshot)
    Here is a line from my log file:
    01/08/13 11:08:48:346 | [WARN] |  | ASU | PDApp | DownloadError |  |  | 6120 | Download Error has come with GDE Error type - -7 and error code - 401
    I tried searching for the same error code in the "knowledge base" but couldn't locate any.
    I am on a Windows 7 (x64) machine. I also have CS5.5 installed.
    Anyone have this problem? Please help or point me in the right direction if you can. Thanks!

    Thanks Romsinha,
       I tried the above steps, with no luck.  I have admin rights on both laptop and desktop I'm trying to install to.  I have updated my AAM on both machines with no issue (when using the direct link above). But when I click the 'Try' link to download an application, it shows the scrolling status bar for a few seconds, then  "Installation Failed"  'Download error. Press Retry to try again or contact customer support. (-7)'   Retry only produces same results.
    Both machines are running Win 7 Pro - SP1 64bit
         (laptop - 16 GB RAM & Core i7-2760QM 2.40 GHz processor)
         (desktop - 8 GB RAM & Xeon W3520 2.67GHz processor)
    I am running in a corporate setting with I'm sure all sorts of Firewall protection etc...
    I'm planning on asking for a CC membership, but wanted to check out the new features first....
    Thanks!

  • Error message R6034 and Error 7 (windows error) 1114

    Hi!
    I have tried installing the latest itunes update and it has failed. I get the runtime error message R6034 and Error 7 (windows error) 1114. I have tried many times, uninstalling and reinstalling the versions as advised in some of the related threads but still face the same issue. I am now unable to get in Itunes. My computer runs on windows vista, 32 bit. Please advice resolution.
    Thanks,

    Doublechecking. Have you worked through the following user tip?
    Troubleshooting issues with iTunes for Windows updates

  • SNP Optimizer Read Error Error id : 600 and Error id : 812

    Hi All,
    I am rebuilding my SNP in a new SCM environment.  I have transfered my PDS's and WorkCenters/Capacity via the CIF.  These appear fine when I display and have performed the LC Check for the resouces using the TOOLS at  /n/sapapo/res01 tcode but all appeared green.  I am using standard Hierachies and think they are fine and assigned to the Planning area correctly. 
    When I press the "oprimizer" ...It runns until it gets to the "Loading Planning Data" then it fails with a "Error when Reading Planning Data" and "Optimizer: an internal error occured".  This error occurs very quick once it starts this process and complexity does not seem to matter. 
    When lookinjg at the Trace File of the log I see the below activity that seems to be the cause but I do not know what the errors mean or where to reference them? Has anyone else encountered this previousluy or know where can investigate this further.  Any help or directions on Error id : 600 and Error id : 812 would be great!
    Thanks in advance for all your assistance in this!  
    ===
    <i> 19.04.2011 19:04:39 core_msgmgr.cpp(440) 'MsgMgr' * Sending progress number 801 to OutputInterface from []
    <i> 19.04.2011 19:04:40 core_msgmgr.cpp(440) 'MsgMgr' * Sending progress number 802 to OutputInterface from []
    <i> 19.04.2011 19:04:41 snpopsvr_script.cpp(176) 'SuperVisor' Running in 700 data version mode...
    <i> 19.04.2011 19:04:41 snpopsvr_script.cpp(862) 'SuperVisor' Interpreted run time limitation as minimum run time (300 sec.), set run time limitation to 900 seconds.
    <i> 19.04.2011 19:04:41 core_msgmgr.cpp(440) 'MsgMgr' * Sending progress number 803 to OutputInterface from []
    <i> 19.04.2011 19:04:43 core_supervisor.cpp(728) 'SuperVisor' <M> Invoking module 'SNPRModelGenerator' [6]->init
    <i> 19.04.2011 19:04:43 core_supervisor.cpp(750) 'SuperVisor' <M> Returning from module 'SNPRModelGenerator' [6]->init = success [ctx size : 0]
    <i> 19.04.2011 19:04:43 core_supervisor.cpp(728) 'SuperVisor' <M> Invoking module 'SNPRModelGenerator' [6]->download
    <i> 19.04.2011 19:04:43 rfc_connection.cpp(599) 'MsgMgr' <rfc> calling function module /SAPAPO/MSDP_OPT_UPLOAD
    <e> 19.04.2011 19:04:53 snpopsvr_script.cpp(286) 'SuperVisor' <!> CORE EXCEPTION : 14 =
         RFC_RC (RFC_EXCEPTION) Exception raised
         RFC_ERROR_GROUP (RFC_ERROR_APPLICATION_EXCEPTION) The called function module raised an exception
         key=ERROR
         message=ERROR
         exception=ERROR
    <i> 19.04.2011 19:04:53 core_msgmgr.cpp(394) 'SuperVisor' <GUI MSG> Error id : 600 [class : <default>] - no params
    <i> 19.04.2011 19:04:55 core_msgmgr.cpp(394) 'SuperVisor' <GUI MSG> Error id : 812 [class : <default>] - no params
    <i> 19.04.2011 19:04:56 optsvr_main.cpp(1166) 'MsgMgr' Current check values:
    [CHECK_EQUAL]
    [CHECK_UPPERBOUND]
    nPEAK_MEMORY_linuxx86_64 = 79488
    [CHECK_LOWERBOUND]
    <i> 19.04.2011 19:04:56 optsvr_main.cpp(1209) 'MsgMgr' Performance values:
    bSuccess     false
    nCPU_TIME     0
    nPEAK_MEMORY     79488
    nREAL_TIME     17
    SNP BuildMode     Release
    SNP Runtime requested     900
    tracefile     optsvr_trace20110419_190439_2e12.log
    <i> 19.04.2011 19:04:56 optsvr_main.cpp(1235) 'MsgMgr' Performance Monitor values:
    nCPU_TIME     0
    nPEAK_MEMORY     79488
    nREAL_TIME     17
    <i> 19.04.2011 19:04:56 optsvr_dsr.cpp(96) 'MsgMgr' <writeDSRdata> tracing not active => no DSR written
    <i> 19.04.2011 19:04:56 optsvr_main.cpp(1256) 'SuperVisor'
    Finished->FAILED ...

    Thanks for the reply...
    I was able to manually enter and save an SNP planned order via the planning book. 
    I have failures where my Input material is UOM=TON and Output is UOM=TON and also where input is UOM=TON and output is UOM=KG. I am able to switch between these UOM's in the planning book and product view.
    When I have DEBUG2 on via OPT10 I see:
    Message Log:
    Input parameters
    Customizing Settings
    Active BAdI Implementations
    Step 1: Data read and model creation started at 16:36:35 on 04/22/2011
    Runtime 00:00:00 to measuring point Step_1_Start
    Runtime 00:00:01 to measuring point Initializations
    Runtime 00:00:00 to measuring point Arc_Read
    Runtime 00:00:01 to measuring point SNP_Planed_Order_Deletion
    Runtime 00:00:00 to measuring point Procurment_and_Transport_Order_Deletion
    Runtime 00:00:00 to measuring point Arcmat_Read
    Error occurred when reading data
    Trace File:
    <1> 22.04.2011 16:36:36 rfc_connection.cpp(631) 'MsgMgr' <rfc> RfcCall for /SAPAPO/MSDP_OPT_UPLOAD
    <1> 22.04.2011 16:36:36 rfc_connection.cpp(640) 'MsgMgr' <rfc> RfcReceive for /SAPAPO/MSDP_OPT_UPLOAD
    <2> 22.04.2011 16:36:38 core_linux_proc.cpp(40) 'MsgMgr' Mem measurement (KB): current=144108 peak=144108
    <2> 22.04.2011 16:36:40 core_linux_proc.cpp(40) 'MsgMgr' Mem measurement (KB): current=144108 peak=144108
    <2> 22.04.2011 16:36:42 core_linux_proc.cpp(40) 'MsgMgr' Mem measurement (KB): current=144108 peak=144108
    <e> 22.04.2011 16:36:43 snpopsvr_script.cpp(286) 'SuperVisor' <!> CORE EXCEPTION : 14 =
         RFC_RC (RFC_EXCEPTION) Exception raised
         RFC_ERROR_GROUP (RFC_ERROR_APPLICATION_EXCEPTION) The called function module raised an exception
         key=ERROR
         message=ERROR
         exception=ERROR
    <i> 22.04.2011 16:36:43 core_msgmgr.cpp(394) 'SuperVisor' <GUI MSG> Error id : 600 [class : <default>] - no params
    <i> 22.04.2011 16:36:43 core_msgmgr.cpp(394) 'SuperVisor' <GUI MSG> Error id : 812 [class : <default>] - no params
    <i> 22.04.2011 16:36:43 optsvr_main.cpp(1166) 'MsgMgr' Current check values:
    [CHECK_EQUAL]
    Thanks again!

  • System error code 5 (and error code 80240016)

    I was having trouble with Windows updater (error code 80240016) when I tried to install SP1, and then found the solution was to open service command and follow the instructions given on this microsoft site (http://support.microsoft.com/default.aspx/kb/957307) . BUT it didn't work, because for some reason access was denied and it kept saying 'System Error Code 5".  I don't know what it means and how to fix it!
    Please help, I can't update windows until this issue is resolved!

    Hi
    Sorry that article did not help.
    I was under the impression that the article was operating system agnostic and that the settings would work for any version of Windows.
    I would recommend that you take advantage of the free, unlimited support that Microsoft is offering for Windows Update issues.
    This will connect you directly with the support engineers that specialize in WU problems. Be sure and include an exact description of the problem, including the proxy connection you use.
    Windows Update No-Charge, Unlimited Support:
    https://support.microsoft.com/oas/default.aspx?gprid=6527
    You might also want to peruse the Windows Update newsgroup to see if anyone there may have seen and possibly solved a similar problem.
    Discussions in Windows Update:
    http://www.microsoft.com/communities/newsgroups/en-us/default.aspx?dg=microsoft.public.windowsupdate&cat=en_US_56d1dd45-de9e-4fc5-9bc1-2d1d0de6daee&lang=en&cr=US
    Good luck.
    If this post helps to resolve your issue, click the Mark as Answer button at the top of this message.
    Ronnie Vernon
    Microsoft MVP
    Windows Desktop Experience

  • Install error on CC and ERROR code 50. Also AE would crash due to full disk cache and close unable to select from menu to change.

    I have recently installed and used Creative Cloud and also install several applications. The apps and cc ran fine but Adobe AE would crash upon startup of the app in which is prompted a message stating ...the drive which it is installed on does not have enough memory or disk cache is full. Please change in preferences. I attempt to do so but AE shuts down after I select ok. I installed the cleaner tool and uninstalled all Adobe products and attempted to reinstall creative cloud and now I get a "...We've encountered the following issues: Creative Cloud desktop failed to install. (Error code:50)
    I have been trying to resolve this issue for three weeks now which I did finally get it to work by opening the AE by selecting a AE file. I was able to use it 3 times for the amount charged for the monthly fee and I also downloaded several of the other apps but was
    unable to use them due to this issue then uninstalled with Adobe cleaner tool!
    PLEASE HELP!
    Message was edited by: Paul Whitehurst

    Jeff,
    I have tried to install on another drive after downloading Creative Cloud clean-up and uninstalled all adobe creative cloud. So if I erase my temp folders it might work?
    Please help I have basically paid for my 2nd month and only used a few times.
    Thanks,
    Paul

  • Error 8J 290 and Error in method PO_POST

    Hi Guys
    When changing prices to an existing PO linked to a sales order our client gets the following errors after clicking save button:
    "No update of sales order 16668 from purchase order
    (error 8J 290)"
    and then
    "System error (error in method PO_POST)". 
    Why is this happening? Kindly Rush me any answers, oss notes, etc.
    Our client is using SAP-AFS ECC 6.0 version.
    thanks
    Maruthi Ram
    Edited by: MARUTHI RAM on Oct 31, 2008 6:56 AM

    Hi,
    As per your thread it seems that PR has been generated automatically while creation of Sales Order and you have converted it to PO. (Same as Third-Party Sales Process). If yes then read following carefully.
    If a PO has not yet been created, to confirm the quantity change in the requisition, change the sales order with transaction code VA02. Select the item and choose Schedule lines for item. Double-click the schedule line with the confirmed quantity. Choose the Procurement tab, choose Edit and check if the quantity for the purchase requisition has also been updated.
    If a PO has already been created, to confirm the PO change, change the sales order with transaction code VA02. Choose Document flow. Select the purchase order and choose Display document.
    Result: - The sales order quantity has been changed. If a PO existed, you have changed the PO quantity. Otherwise, you have changed the requisition quantity.
    In short, first change the Sales Order quantity and then change the PO Quantity.

  • I get error MSVCR80.dll and error 7 when i try to open itunes

    I'm trying to open itunes on my PC and it comes up with errorMSVCR80.dll and error 7 (windows error 126) and will not open. Any suggestions?

    Solving MSVCR80 issue and Windows iTunes install issues.

  • Everytime i open itunes it says "error code (-42032)" and "error code (42022)" how can i resovle this problem?

    this problem has recently occured for unkown reasons, i opened itunes and error messages where there, i have tried re-installing itunes but it freezes and makes me cancel the dowload. when i plugged my i-pod into the computer it didnt open itunes (which it should do) and when i opened itunes the ipod connection wasnt being picked up. how can i fix this problem?

    Hello DrewyBoi
    Check out the article below to completely remove iTunes and associated software in order. Then install iTunes again; your library will still be intact after the installation.
    Removing and Reinstalling iTunes, QuickTime, and other software components for Windows XP
    http://support.apple.com/kb/HT1925
    Thanks for using Apple Support Communities.
    Regards,
    -Norm G. 

  • Using error codes.txt and error rings don't allow parameter inputs like custom error rings?

    The error ring is very useful, especially with its parameterized inputs you can specific with %s, %f and %d parameters.  I'd like to do the same thing in my fixed error codes using the error ring so that I can localize them into mulitple languages, but it seems that LabVIEW error codes from project text files never detect or support the parameter inputs, you get a error ring, but no input parameters.  If you use the same string in a customer error code, it gives you the parameter input but then its hardcoded and you can't localize it.  What gives?
    Is there some other way to configure the error rings to use a project file for the error codes but still support the parameter inputs?
    Solved!
    Go to Solution.

    Hi Mike_King
    Here is a VI snippet that I created with two different approaches, in the first one I used the format into string, the second one the function search and replace.
    Here are some links with information about the functions that I used.
    Format Into String Function - LabVIEW 2011 Help
    Search and Replace String Function - LabVIEW 2011 Help
    Regards
    Esteban R.
    Attachments:
    Generate error code.png ‏34 KB

  • Error messages: "Done, but with errors on page" and "Error on page" on the Verizon log-in page.

    How do I remove/correct the page errors above? The error msgs only appear on the VZ web site log-in page.

    Those are typically from what I presume you're using is Internet Explorer not liking the way some of the code is formatted on the website. They can be ignored if you are not having issues with the site. Each browser will complain about something and call it an Error in some way or another. You have to have an extremely basic page to not have a complaint about an error, or one crafted for every web browser out there.
    ========
    The first to bring me 1Gbps Fiber for $30/m wins!

  • Error Code: -3 and Error -1404

    When I attempted to download the latest iTunes update, it appears as though iTunes installed fine, but there was an error with the included Quicktime. The error code is 3.
    Then when trying to run iTunes, the message comes up that I need Quicktime version 7.0.3, and what I have is 7.0.2, so re-install.
    After going around in that circle a few times, I download the standalone Quicktime installer, but that yields error 1404 and 1402.
    Next, I uninstall iTunes, discard the relevant files in the iPod bin folder, and attempt to again install iTunes. Same error messages as originally.
    I don't know how to proceed now. I have no access to iTunes or updating my iPod. These "upgrades" always seem to be a headache...
    Any help would be appreciated. Thanks.

    Harry,
    Here is a post that I added three weeks ago. It includes a solution that worked for me. I hope that it works for you! Good luck.
    Hey troubled Podheads,
    I was one of the legion with problems in downloading iTunes6 and QT7 for Windows until I tried something (I must say that I am not a pc wizard and I don't know the technical reasons for why the following worked, it just did! So if there are any pc geeks out there, be sure to chime in). Anyway, this is what I did. First uninstall QuickTime if you do have it on your pc. If not, just go to the next step:
    Go to START, then RUN. Type in regedit and then click OK. Your REGISTRY EDITOR should open. You should see HKEYLOCALMACHINE in the scroll down menu on the left, with a small box to its left. Make sure that the inside of the box has a negative sign - this will open up the next set of subfolders. Next, make sure that the subfolder, SOFTWARE, has a negative sign in the small box to its left. Next, make sure that there is a negative sign in the box next to the subfolder entitled, Apple Computer, Inc. You'll see at least three subfolders: iPod, iTunes and QuickTime. Click once on the QuickTime folder until it is highlighted and then delete it. You will be asked if you want to delete QuickTime and its subfolders. Click ok and then close out the Registry Editor.
    Next, download the stand alone QuickTime 7 at this link (you may have to cut and paste this link to open this website):
    http://www.apple.com/quicktime/download/standalone.html
    When you download the stand alone QT7, you may get a couple of error messages (I did), but if you repeatedly click ok (like I did), the QT7 player should load with no problems.
    Again, I am no pc geek, but this worked for me and I have gained access to iTunes6 (with video capacity) and my complete library is intact. Nothing like trial and error!! Good luck -- I hope this works for all of you frustrated Podheads out there!

  • How does the Error Row Definition and Error Message Lookup setup work?

    Suppose I use web ADI to load data to PA_TRANSACTION_INTERFACE_ALL (This is Oracle standard Interface table for Projects)
    I call a Importer (The Importer is called post upload of data to above Interface Table). The Importer will update the Interface table columns (TRANSACTION_STATUS_CODE) and (TRANSACTION_REJECTION_CODE) with values based on the clearing all validations. If validation fails, the column, TRANSACTION_STATUS_CODE is updated with value 'R' and TRANSACTION_REJECTION_CODE has the error code. This error code is stored in the Lookup, with Lookup Type = 'TRANSACTION REJECTION REASON'
    I define the Error Row Definition as follows -
    select * from PA_TRANSACTION_INTERFACE_ALL where TRANSACTION_STATUS_CODE = 'R' and BATCH_NAME = $param$.batchname (BATCH_NAME is populated in the Web ADI Template)
    I define the Error Message Lookup as -
    select meaning from apps.fnd_lookup_values where lookup_type ='TRANSACTION REJECTION REASON'
    and language='US' and lookup_code = $param$.TRANSACTION_REJECTION_CODE
    I have defined the , Document Row : Interface Attribute Mapping - with the column, ORIG_TRANSACTION_REFERENCE (THe column with the Unique value for a row and links the Excel row with the Interface table)
    I feel my setups are fine. Still why the Error -
    An error has occurred while running an API import. The ERRORED_ROWS step 275:ER_501996, parameter number 1 must contain the value BIND in attribute 1.

    Duplicate post -- https://community.oracle.com/thread/2615675

  • Error-1073​807253 and Error-1073​807360

    Hi,
    I am currently working a code for some scales (GFK 330a) I can get them to read out using the Basic Read/Write vi found in the examples. I have made a few slight modifications to the code by putting it in a while loop and adding a Wait till (ms) function in it so it only takes data every second. I keep getting these two errors while using this code 1) Error-1073807253 occurred at VISA Read (Hex 0xBFFF006B) a framing error occurred during transfer and 2) Error-1073807360 occurred at Property Node (Hex 0xBFFF0000) unknown system error (misc. error). After I hit ok on the error screen the program goes back to work and gives me the correct data until another error occurs then I repeat the process. I can't sit at the computer waiting to hit ok everytime an error comes up. What do I need to do to fix these errors? Here is a picture of my program.
    Thanks,
    Chet
    Attachments:
    Scale_code.png ‏84 KB

    You say that you are absolutely sure that your settings (baud rate, stop bit, etc.) are exactly the same in Measurement and Automation Explorer (MAX) as they are on your device?
    How did you implement the delays in your program? Have you tried the delay configuration in the following example?
    http://digital.ni.com/public.nsf/allkb/F3E0621CB71​AA16786256F970000FC57