Assembly indicator in BOM doesnu2019t consider BOM Usage
In a business scenario we are using two types of BOM 1. Production BOM & 2. Engineering BOM.
Letu2019s say for Material 'A' there is an engineering BOM & it consists of two components say 'B' & 'C'.
Material 'C' has its own BOM but with usage "Production".
Still in transaction CS03, when we display Engineering BOM (Usage: 2) for Material A.
Assembly indicator for material 'C' is active though there is no engineering BOM for material 'C'.
Is there is any condition for checking BOM usage for assembly indicator? Or what can be the solution to take into consider BOM usage.
PP gurus please help.
Many thanks in advance.
Hi Sumedha
BOM usage defines the area (such as engineering/design or production) where a BOM can be used.
when ur material A is having C as component and C is having its own bom so it will show that in the system. bom usage is only for using the bom in diffrent area
if u have an engineering/design BOM and if u want to use that in production that time it will give an error
or massage that BOM usage is not as per requriement
hope u got it
regards
Sachin
Similar Messages
-
Dear Gurus
Please tell me, In which table I can find assembly indicator with related to a BOM.
Thanks & Best Regards
CharithHi Rupesh,
Use FM CS_BOM_EXPL_MAT_V2 with input as given below.
CAPID - PP01
DATUV -System date
EMENG - Quantity as 1
MKTLS = X
MEHRS = X
MTNRV = Parent Material Number
SVWVO = X
WERKS = Plant
From the output internal table STB get the Field XTLTY. If XTLTY = M, then consider that as Assembly. Apart from this you can also use the Internal table MATCAT. All the Materials MATNR in this table MATCAT are nothing but assemblies.
Hope its clear.
Thanks & Regards,
Ramagiri -
Copying assembly indicator in BOM
hI ,
i AM COPYING A bom FROM ONE plant to other plant ..In first plant item is a sub-assembly with assemby indicator. When i am copying to other plant this indicator is not copying. Because of which i couldn't able to see its components.
Regards
PatnaikPatnaik,
BOM Copy happens at single level only. When you are copying the BOM from one plant to another only the Header material BOM gets copied. You need to create/Copy the subassembly BOM for the new plant. Once this is done system would automatically activate the "Assembly Indicator" in the header level bom for subassembly components.
Regards,
Prasobh -
How to find 'Assembly' indicator in a BOM explosion FM
Hi experts,
I need a function module to explode BOM for Materials which are having checked by Assebmly indicator.
I tried fm : CS_BOM_EXPL_MAT_V2. But i didnt find a field for this indicator.
Can any of you tell me how to find weather 'Assembly' indicator of a material is checked, using a FM.
Please !
Thanx.
Matt.Hi,
U can find it in another way by using Table MARC,
if the value of SOBSL field is 50 in MARC then its an assembly.
Hope it helps!!
Regards,
Pavan -
Assembly Indicator in BOM Level
hi,
can any one let me known any function module to get the list of all materials at BOM
i,e if i give a material number i should get all the material including the assembly for materials.
or let me known where the assembly indicator will stored at table level
i have seen CS_BOM_EXPL_MAT_V2 function module which give all levels of the materials and gives the assembled
material also but
My requirement is for given date range, plant and material i should get materials including assemblies with the total quantity used in that given date range.
Regards,
R K.
Edited by: R K on Aug 12, 2010 2:17 PMhi,
Thank you very much for effort in helping me on the issue,
I have already seen all the table in the list previously.
i closed the issue, using the fm CS_BOM_EXPL_MAT_V2
after using the above fm we will get all the assembly materials
into table MATCAT and passed all those materials and date range to S026 table which gives
quantity day wise, collected those quantities material wise into another final table .
Regards,
R K -
Table for Assembly indicator checkbox in BOM
Please inform me about Table for Assembly indicator checkbox in BOM
Field name--- STLKZ.
If table is not there then how to find if this field is checked or Not checked in development programDear Mayuresh,
There is no table where in you can get this information which has got an assembly of its won.
Either you can use CS11,CS12 or CS13 for limited level explosion or else to identify for which
components an assembly exists for itself.
Or else at Functional module level.
Regards
Mangalraj.S -
Co-product indicator is not copied to BOM
Hi Experts,
I have created the materials with co-product indicator in MRP2view and using this material as component in BOM. However the co-product indicator is not copied to the BOM in Item details basic data view. When I crate a production order, components are not having co-product indicator in production order component view.
When I create the BOM, system is accepting the quantity with negative value.
What could be the reasons that system is not copied the co-product indicator in BOM.
Pl provide your valuable suggestions.
Best answer will be rewarded.
Thanks & Regards,
Surya
+919000440032.Hi
Steps for the coproduct feature in SAP are as follows :
1. Create Material Masters for the main product and Coproduct. Select the Indicatore co-product for the co-product material. In MRP 2 View click the Joint Production Tab and maintain the Approtionment Structure i.e. One Main product is equal to X coproducts.
2. Create the BOM for the Main product and maintain the Co-product as an Item with negative quantity and click the Coproduct check box in item detail manually. Then only this will be flowing to Production order .
Note : System by default will not make it to flow to BOM from the MaterialMaster. You need to manually tick the check box in BOM either during BOM Creation or change.
Hope this will help you.
regards
radhak mk -
Cad indicator in BOM header or bom item
Hi All
Cad indicator in bom header or bom item is set only using the CAD interface.The system sets this indicator if the bom header or item is generated in a CAD system and transferred to the SAP System via an interface.
If we upload bom with our upload program then this indicator cannot be set.
Is there is any way by which we can set it for all boms which are uploaded through upload program ?Hi,
Why would you want to do that? Wouldn't it be incorrect representation?
Regards,
Vivek -
Table field for Assembly indicator
Hi,
What is the table in which the assembly indicator (BOM) is getting stored?
Regards,
Charumathi.BHi,
Check table STPO and field is STKKZ.
You can check out this link for BOM related tables-
http://www.sap-basis-abap.com/sappp007.htm
Regards,
Sujit -
Production BOM and Engineering BOM
Dear Gurus ,
I want to know difference between Eng BOM and Prod BOM . We have standard multilevel engineering BOM but if I use that BOM for routing assignment I can only see 1 st level components . Can I put all components in single level so that I can assign them in FG routing and pick list will have all the components ?
We are thinking of considering all assy as phantom so that there would be only one prod order for FG .
NealHi,
The engineering BOM is as designed material BOM. It may include all the part upto the level of nuts & Bolts & also the engineering drawings. But in Production BOM you may not include the engg drawings & the C class material like nut & bolt, which may be planned on Reorder point planning.
I hope the answer is clear.
Regards,
Prashant -
How to convert WBS bom to material BOM in PP-ps scenario
Hi experts
i am working on PP -PS scenario anyone can suggest how to convert wbs bom to material BOM as well as what are the further steps related to project mrp as well as project planning
your valuable reply is really appreciated
with regards
shaikHi,
In additional to the above u can choose the BOM usage as 3- Universal.
And then transfer WBS BOM using CN33.
Regards
JB -
Hi All,
We have a business scenario where there is Group BOM without plant and a Plant BOM with same usage (2).
We hava requirement below
If we make any changes in Group BOM with a change number, Plant BOM is also updated. But if we make any changes to Plant BOM with change number, Group BOM should not be updated.
Any ideas how we can map this requirement?
Both BOM have same usage - engineering -> 2
Regards,
Aby ThomasAny changes in Group BOM with a change number, Plant BOM is also updated when they are referenced to each other (CS07).
In this case both share the same BOM number and changes are always reflected both ways.
In my opinion a solution would be :-
1) Dereference the BOM's (CS09) , this will remove the plant bom from system.
2) Create the plant BOM (as a copy of group bom)
3) And then build enhancements in CS02 to copy online the changes in group BOM to plant BOM. -
How to Switching Alternate BOM to Primary BOM
Dear All
Need help...
I have already try to switch from alternate BOM to primary BOM. but why it can not effect anything? any step that i mis?
my step is :
1. Navigate to the Substitute Components window. choosing the Substitutes button from the Bills of Material window.
2. Enter a substitute item for the component.
3. Enter the quantity of the substitute item needed to replace the full component quantity.
its correct ??
Best Regards,
The poohMRP plans according to primary bom. If you run ASCP constrained plan, you can set the plan options such that it will look at alternates as well.
If you run MRP or unconstrained bom, you will have to change the primary bom itself (via ECO or BOM changes).
You can also consider using the alt. bom when creating the work order manually.
Sandeep Gandhi -
Creation of Variant BOM using Simple BOM
Hi
I am havign a production BOM, i wanted to create Variant BOM using Production BOM.
Pls let me know, whether we have any Function modules for the same.
Regards
MDcheck SAP std.program to create variant BOM .
<b>RCSBI030</b>
Regards
Prabhu -
Function Module for creating Functional Location BOM and Equipment BOM
Hi All,
Is there any function module for creating and changing Functional Location BOM and Equipment BOM ???Hi,
Tables for Eq., BOM: EQST, STKO, STPO.
Tables fro Fun., Loc., BOM: TPST, STKO, STPO.
You can use FMs: CS_BOM_EXPL_TPL_V1, CS_BOM_EXPL_EQU_V2 & CS_BOM_EXPL_MAT_V2 for extracting the appropriate BOM related data.
And for the Alternatives please check the customizing or check with your respective Module experts for the appropriate configuration.
Hope this helps.
Best Regards, Murugesh AS
Maybe you are looking for
-
BI Modeling Question - Load time, efficiency
Hi Experts, This is a two-part question. Scenario: I have a Standard DSO- overwrite (DSO1) at accounting line item level which pushes data to another Standard DSO-overwrite (DSO2) at Monthly Level. This Monthly DSO pushes data to a cube for Monthly
-
Album illustrations don't match
Since a while the album illustrations don't match up on my iPhone. They're synchronised on iTunes, but when I play music on my iPhone, I never get the right album illustration. What's up with that?
-
Error Message and Shut Down When Trying to Add Security Policy
Acrobat 8.1.5 I'm trying to add a security policy. When I click on Finish, I get a message saying there has been an error and Adobe must shut down. I've checked for updates, restarted Adobe, restarted my computer. Nothing is helping. Here's the deta
-
List of SAP Modules applicable to a Pharmaceutical Organization
Hi, I am looking for list of SAP Modules applicable to Pharmaceuticals Organization. Please let me where can I find this information. Regards, Shruti
-
Can any body tell me how much bw configured on port from below mentioned config details.
sh int GE-WAN3/1.720 GE-WAN3/1.720 is up, line protocol is up Hardware is GigabitEthernet Interface, address is 0013.7f6d.2bc0 (bia 0013.7f6d.2bc0) MTU 4474 bytes, BW 1000000 Kbit, DLY 10 usec, reliability 255/255, txload 29/255, rxload 130/