Attribute_Chng_Run Failed.... Data loading not possible.

Hi Dear Expert,
I am facing  another issue. And this is little different.
This time Attribute_Change_Run got failed. And I am trying to activate it but no luck.
Due to this I am not able to load any data ( Master & Transactional Data ).  And the problem is I am not able to activate or delete the request in ODS and Cube  too. Whenever I click on delete or Activate button , its showing that is the Request is deleted with message RSM7** . And after few seconds, there is no reaction in system. The request are  still there in the CUBE and ODS. 
There is no short dump in ST22 too. I don't know how to proceed . Not getting any system error also.
Please suggest,
Sanjana

Hi Suman,
Thank you for replying .
I followed your steps by De-activating  Aggregates. But mu bad luck, Its not working too.
And one more thing I noticed, The Hierarchy /Attribute Change run got cancelled on 12-AUG-2011 at 7:00:09 AM.
When I checked in SM37  ..... The job  BI_WRITE_PROT_TO_APPLLOG  is getting cancelled from 11-AUG-2011 at 16:12:24 PM.
So I'm thinking , it might happen thet the ACR is getting cancelled due to BI_WRITE_PROT_TO_APPLLOG cancellation.
Please Suggest,
Sanjana

Similar Messages

  • 5310 "Data transfer not possible" calendar sync is...

    I'm trying to get my Nokia 5310 to synchronise its calendar with my work's Outlook 2003, using PC Suite 7.1.26.1.  At work they use Windows XP and Outlook 2003 SP2.  I don't want to bring my USB cable into work, so I'm using bluetooth to connect.  The connection itself works fine - I can browse the 5310's media content, calendar and contacts using my computer.
    The problem is with synchronising calendar with Outlook.  It just won't do it.  Every time, I get a "Data transfer not possible.  Check data connection" message on the phone and a "PC Sync was unable to locate your Outlook message store" error in the PC Suite sync log.
    Things I have tried:
    Repair PC Suite.
    Install new settings (spanner star button) and go through the wizard again.
    As 2, but with manually selecting the Outlook folders on my profile (which were, in any case, already preselected correctly).
    Copying a new profile and trying to sync with that.
    Putting in (the same) username/password in PC Suite and the phone's "sync and backup" option.
    None of these works.  My work computer will happily sync with Google calendars, but won't sync with my phone.
    I've had a good look through the forums but can't seem to find any solutions that work for me.  Does anyone have any ideas of how I can get this to work?

    Try one more thing. This worked for me.
    1. Remove ALL email profiles.  -
    2. Recreate profile - don't forget to write down your Email exchanger server address. This will force Microsoft outlook to startup as if your  a new user but will load your existing email from the server.
    3. Setup PC Sync -- again
    - this has been a pain in the neck!! - something gets corrupted in the profile that PC Sync does not like.

  • 6301 & PC Suite - "Data transfer not possible. Che...

    Well, as the title says really.
    Upgraded from 6280 -> 6301.
    I use Outlook 2003 and sync contacts & calendar.
    Sync'd the 6280 before finalising upgrade, plugged in the 6301 with a mini-usb cable (All driver reports it installed new hardware fine) once it had fully come into service and it wouldn't sync.
    The phone displays "Data transfer not possible. Check connection" and Nokia PC Sync shows the warning "The mobile phone as not responded". It's solution is "Please ensure your phone is in the standby mode, then restart the Synchronisation. "
    Have updated to latest version of PC Suite 6.85.
    A bit annoying, as I no longer have any contacts info on the new phone...
    Running XP, AMD 3ghz, 4gb ram.

    Having spent many hours on this I have now got it working...
    This is how :
    1. On the phone go to : Settings: Sync and Backup: Server Sync: PC Syncronisation and enter a username and password.
    2. Select Synchronise in Nokia PC Suite, in the Connected to 6301 window click the spanner (settings) icon. Now click the Adjustable wrench (Advanced) Icon and go to the sync profile tab and enter the same username and password that you used on the phone. Click OK twice and sync away...
    Message Edited by kage64 on 05-May-2008 11:04 PM

  • Data transfer not possible? Nokia 2700 classic syn...

    I have Ovi setting on my 2700 classic, everytime i try to sync contacts - the prompt comes like "data transfer not possible". Help me with it also plz tell me any way of getting contacts back on phone/sim from ovi without PC. Addl. Info:- i had syncd the phone successfully on gprs without pc and i am so hoping that their must be some way out. Thanks

    I am also having the same problem. I am using Nokia 7210. Please help me

  • PC Suite 7 – Data transfer not possible. Check dat...

    When I try to use (open, update, modify etc.) the “contacts list” in PC suite version 7.0.7, I always have the following error: “Data transfer not possible. Check data connection”. Instead the SMS list works fine. My phone is Nokia 6267.
    Anyone has a solution?
    Best Regards
    Bix123

    Hi everyone,
    I had the same problem for months with many PC Suite versions & both XP service packs until I tried a phone setting just for testing and everything worked out fine In my phone (3110c) under Settings / Connectivity / Data Transfer / PC Sync, I filled in a random User name & Password and voila!!! All contacts copied just fine!!! I hope this works with other models with the same menu as well. It looks that it's not a PC Suite problem after all (at least for me that is).
    Hope I helped you guys
    Spiros
    Greece

  • How to Debug the Failed Data loads?

    Hi..All
    Can Any one plz explain How to Debug the different types of Failed Data Loads?
    Thanks & Regards
    Jonn

    Hi Jonn,
             If any data failed ....1st analyze where it occurs according to that what we have to decide...
    Analysis:
    1.Check the Status Tab in RSMO--here we can get error information
    2.Check the Details Tab in RSMO--here we can get whether extraction is completed,and where it is exactly failed i.e while updating from PSA or in Update rules etc
    3.Check the corresponding request job log in SM37.
    4.Check whether any shortdump in ST22.
    5.Check the Request status in the Target...some times activation job failed in SM37 but in the Target we found as activated.
    6.Check BD87 Transaction for any IDOC errors.
    7.Check SM58 for TRFCs
    Hope this helps u.....
    Mohan

  • Error while activating DSO ....date is not possible....

    Hi all,
    While activating the DSO ,I am getting the following error: Value '20022009' of characteristic 0DATE is not possible
    In FEB 20/02/2009 is possible ...but why system giveing this message...?
    Any suggessions...on this..
    Thanks....Bk
    Edited by: BK BI on Feb 24, 2009 9:39 AM

    Hi BK,
    Looks like in your case 20 is being considered as month which is obviously invalid hence no SID could be generated for 0calday and hence the DSO fails when activation.
    Now as Daya and anil mention you could change the date to format yyyymmdd and try reloading the file.
    The general principle would be go to menu settings ---> status and check the logged on date ...the format being shown to you is the format you can try loading in.
    Or go to System --- > User profile -
    > Own data --->defaults tab .... check the data format there and enter the value in that format in your file..
    Hope it helps,
    Regards,
    Sunmit.

  • Master data delta update to data souce not possible

    Hi,
    0material_att data source delta update failed for a few days from the process chain and when I tried to manually run the delta infopackage, I got this message:
    Last delta update is not yet completed
    Therefore, no new delta update is possible.
    You can start the request again
    if the last delta request is red or green in the monitor (QM activity)
    I did "manage" for this data source but none of the failed delta run showed in there. I also looked for cancelled jobs in sm37 but nothing came up either. So I ran a full upload without deleting the data as my user is waiting for this fix to be shown in the report. What can I do now to enable the delta run again without deleting the data?
    sharon

    Hi Sharon,
    chk in RSMO for that master data 0material_attr, if there are any red/yellow req. If so change the QM status to RED again and goto IP and trigger the load again (it wil say that earlier delta has failed and if u want to Repeat ;ast delta,) in that give OK and exe the load again.
    In some cases, the datasource will not support repeat deltas, in that case do a re-init for the master data load. (no need to delete any datas.)
    Hope this helps. If you have any queries please ask.
    Thanks!
    Dharini

  • EM12c install failed and deinstall not possible?

    Hi
    i´m having big trouble to install the EM 12c. My first installation try failed, so i think i make a big mistake and delete the folders manually and also with sqlplus delete the sysman schema.
    But now every installation hangs on that point
    INFO: oracle.sysman.top.oms:Still Running...
    INFO: oracle.sysman.top.oms:Still Running...
    INFO: oracle.sysman.top.oms:Still Running...
    INFO: oracle.sysman.top.oms:Still Running...
    INFO: oracle.sysman.top.oms:Still Running...
    INFO: oracle.sysman.top.oms:Still Running...
    INFO: oracle.sysman.top.oms:Completed...
    INFO: oracle.sysman.top.oms:exiting the thread...
    INFO: oracle.sysman.top.oms:[Initializing the EM RCU Runner, Running the Schema Action, Schema Action Completed Successfully]
    INFO: oracle.sysman.top.oms: action logger path calculated finally: /u02/app/oracle/EM12/oms/sysman/log/schemamanager/m_012012_0409_PM/m_012012_0409_PM.TRANSX/
    INFO: oracle.sysman.top.oms:The transx command execution is completed with the status 0
    INFO: oracle.sysman.top.oms:process_id:16oeq76ms5dhu
    INFO: oracle.sysman.top.oms:Failure...
    INFO: oracle.sysman.top.oms:1 error(s) happened in performing the action:
    INFO: oracle.sysman.top.oms:1):
    ORA-00955: name is already used by an existing object
    File:/u02/app/oracle/EM12/oms/sysman/admin/emdrep/sql/core/latest/availability/availability_synonyms.sql
    Statement:CREATE PUBLIC SYNONYM MGMT_AVAILABILITY FOR MGMT_AVAILABILITY
    INFO: oracle.sysman.top.oms:The plug-in Repository Configuration has failed its perform method
    After that i try to delete the failure EM 12c installation with RepManager but it fails again
    ./RepManager vc-db1 1521 vcdb -action dropall -dbUser sys -dbPassword myPassword -dbRole sysdba -reposName SYSMAN -reposPassword myPassword -mwHome /u02/app/oracle/em12c -mwOraHome /u02/app/oracle/em12c/oms -oracleHome /u02/app/oracle/em12c/oms
    processing arguments
    compiling arguments for validation
    Enter password for: sys
    done checking required user credentials...
    done creating arguments...
    creating logger..
    Connection exception in action logger path calculated: /u02/app/oracle/em12c/oms/sysman/log/schemamanager/
    action logger path calculated: /u02/app/oracle/em12c/oms/sysman/log/schemamanager/
    action logger path calculated finally: /u02/app/oracle/em12c/oms/sysman/log/schemamanager/
    no action logger file name from previous session
    action logger filename after search: emschema.log
    action logger filename finally: emschema.log
    filename: /u02/app/oracle/em12c/oms/sysman/log/schemamanager/emschema.log
    newly created: /u02/app/oracle/em12c/oms/sysman/log/schemamanager/emschema.log
    Driver: oracle.jdbc.driver.OracleDriver
    jdbcUrl = jdbc:oracle:thin:@(DESCRIPTION=(ADDRESS_LIST=(ADDRESS=(PROTOCOL=TCP)(Host=vc-db1)(Port=1521)))(CONNECT_DATA=(SID=vcdb)))
    action to perform is: drop
    action is non-transx - RCU based action
    logger null: check if repos user exists..
    logger null: found connection for DB user
    logger null: query DB for repos user existence check
    logger null: REPOS_CONN is null in check repos user... creating new one
    jdbcUrl = jdbc:oracle:thin:@(DESCRIPTION=(ADDRESS_LIST=(ADDRESS=(PROTOCOL=TCP)(Host=vc-db1)(Port=1521)))(CONNECT_DATA=(SID=vcdb)))
    jdbcUrl = jdbc:oracle:thin:@(DESCRIPTION=(ADDRESS_LIST=(ADDRESS=(PROTOCOL=TCP)(Host=vc-db1)(Port=1521)))(CONNECT_DATA=(SID=vcdb)))
    logger null: connection is found null
    Error found: Validierungsfehler für Aktion: [DROP]. Die Fehlerursache war: [null repos-connection found]
    Dropping MDS schema...
    Enter sys user password : stty: Standardeingabe: Das Argument ist ungültig
    stty: Standardeingabe: Das Argument ist ungültig
    Verify : stty: Standardeingabe: Das Argument ist ungültig
    stty: Standardeingabe: Das Argument ist ungültig
    Common components home from environment is /u02/app/oracle/em12c/oracle_common
    Befehlszeile wird verarbeitet...
    Utility für das Erstellen des Repositorys - Voraussetzungsprüfungen werden ausgeführt
    Globale Voraussetzungen werden geprüft
    RCU-6013:Das angegebene Präfix ist nicht vorhanden. Vorhandene Präfixe sind: Keine
    RCU-6091:Validierung von Komponentenname/Schemapräfix nicht erfolgreich.
    Dropping OPSS schema...
    Befehlszeile wird verarbeitet...
    Utility für das Erstellen des Repositorys - Voraussetzungsprüfungen werden ausgeführt
    Globale Voraussetzungen werden geprüft
    RCU-6013:Das angegebene Präfix ist nicht vorhanden. Vorhandene Präfixe sind: Keine
    RCU-6091:Validierung von Komponentenname/Schemapräfix nicht erfolgreich.
    Component is already dropped
    Dropping APM schema...
    Befehlszeile wird verarbeitet...
    Utility für das Erstellen des Repositorys - Voraussetzungsprüfungen werden ausgeführt
    Globale Voraussetzungen werden geprüft
    RCU-6013:Das angegebene Präfix ist nicht vorhanden. Vorhandene Präfixe sind: Keine
    RCU-6091:Validierung von Komponentenname/Schemapräfix nicht erfolgreich.
    Component is already dropped
    Dropping BIP schema...
    Enter sys user password : stty: Standardeingabe: Das Argument ist ungültig
    stty: Standardeingabe: Das Argument ist ungültig
    Verify : stty: Standardeingabe: Das Argument ist ungültig
    stty: Standardeingabe: Das Argument ist ungültig
    Common components home from environment is /u02/app/oracle/em12c/oracle_common
    Befehlszeile wird verarbeitet...
    Utility für das Erstellen des Repositorys - Voraussetzungsprüfungen werden ausgeführt
    Globale Voraussetzungen werden geprüft
    RCU-6013:Das angegebene Präfix ist nicht vorhanden. Vorhandene Präfixe sind: Keine
    RCU-6091:Validierung von Komponentenname/Schemapräfix nicht erfolgreich.
    Is it not possible to delete the existing object with sqlplus, so that the installation process doens´t stopped with this terrible error message above?
    So i don´t know how to get a working Enterprise Manager 12c installation, hope anyone can help me in this issue.
    Kind regards
    ACID25
    Edited by: ACID25 on 24.01.2012 02:26
    Edited by: ACID25 on 24.01.2012 06:10
    Edited by: ACID25 on 24.01.2012 06:10

    Hi
    i´m having big trouble to install the EM 12c. My first installation try failed, so i think i make a big mistake and delete the folders manually and also with sqlplus delete the sysman schema.
    But now every installation hangs on that point
    INFO: oracle.sysman.top.oms:Still Running...
    INFO: oracle.sysman.top.oms:Still Running...
    INFO: oracle.sysman.top.oms:Still Running...
    INFO: oracle.sysman.top.oms:Still Running...
    INFO: oracle.sysman.top.oms:Still Running...
    INFO: oracle.sysman.top.oms:Still Running...
    INFO: oracle.sysman.top.oms:Completed...
    INFO: oracle.sysman.top.oms:exiting the thread...
    INFO: oracle.sysman.top.oms:[Initializing the EM RCU Runner, Running the Schema Action, Schema Action Completed Successfully]
    INFO: oracle.sysman.top.oms: action logger path calculated finally: /u02/app/oracle/EM12/oms/sysman/log/schemamanager/m_012012_0409_PM/m_012012_0409_PM.TRANSX/
    INFO: oracle.sysman.top.oms:The transx command execution is completed with the status 0
    INFO: oracle.sysman.top.oms:process_id:16oeq76ms5dhu
    INFO: oracle.sysman.top.oms:Failure...
    INFO: oracle.sysman.top.oms:1 error(s) happened in performing the action:
    INFO: oracle.sysman.top.oms:1):
    ORA-00955: name is already used by an existing object
    File:/u02/app/oracle/EM12/oms/sysman/admin/emdrep/sql/core/latest/availability/availability_synonyms.sql
    Statement:CREATE PUBLIC SYNONYM MGMT_AVAILABILITY FOR MGMT_AVAILABILITY
    INFO: oracle.sysman.top.oms:The plug-in Repository Configuration has failed its perform method
    After that i try to delete the failure EM 12c installation with RepManager but it fails again
    ./RepManager vc-db1 1521 vcdb -action dropall -dbUser sys -dbPassword myPassword -dbRole sysdba -reposName SYSMAN -reposPassword myPassword -mwHome /u02/app/oracle/em12c -mwOraHome /u02/app/oracle/em12c/oms -oracleHome /u02/app/oracle/em12c/oms
    processing arguments
    compiling arguments for validation
    Enter password for: sys
    done checking required user credentials...
    done creating arguments...
    creating logger..
    Connection exception in action logger path calculated: /u02/app/oracle/em12c/oms/sysman/log/schemamanager/
    action logger path calculated: /u02/app/oracle/em12c/oms/sysman/log/schemamanager/
    action logger path calculated finally: /u02/app/oracle/em12c/oms/sysman/log/schemamanager/
    no action logger file name from previous session
    action logger filename after search: emschema.log
    action logger filename finally: emschema.log
    filename: /u02/app/oracle/em12c/oms/sysman/log/schemamanager/emschema.log
    newly created: /u02/app/oracle/em12c/oms/sysman/log/schemamanager/emschema.log
    Driver: oracle.jdbc.driver.OracleDriver
    jdbcUrl = jdbc:oracle:thin:@(DESCRIPTION=(ADDRESS_LIST=(ADDRESS=(PROTOCOL=TCP)(Host=vc-db1)(Port=1521)))(CONNECT_DATA=(SID=vcdb)))
    action to perform is: drop
    action is non-transx - RCU based action
    logger null: check if repos user exists..
    logger null: found connection for DB user
    logger null: query DB for repos user existence check
    logger null: REPOS_CONN is null in check repos user... creating new one
    jdbcUrl = jdbc:oracle:thin:@(DESCRIPTION=(ADDRESS_LIST=(ADDRESS=(PROTOCOL=TCP)(Host=vc-db1)(Port=1521)))(CONNECT_DATA=(SID=vcdb)))
    jdbcUrl = jdbc:oracle:thin:@(DESCRIPTION=(ADDRESS_LIST=(ADDRESS=(PROTOCOL=TCP)(Host=vc-db1)(Port=1521)))(CONNECT_DATA=(SID=vcdb)))
    logger null: connection is found null
    Error found: Validierungsfehler für Aktion: [DROP]. Die Fehlerursache war: [null repos-connection found]
    Dropping MDS schema...
    Enter sys user password : stty: Standardeingabe: Das Argument ist ungültig
    stty: Standardeingabe: Das Argument ist ungültig
    Verify : stty: Standardeingabe: Das Argument ist ungültig
    stty: Standardeingabe: Das Argument ist ungültig
    Common components home from environment is /u02/app/oracle/em12c/oracle_common
    Befehlszeile wird verarbeitet...
    Utility für das Erstellen des Repositorys - Voraussetzungsprüfungen werden ausgeführt
    Globale Voraussetzungen werden geprüft
    RCU-6013:Das angegebene Präfix ist nicht vorhanden. Vorhandene Präfixe sind: Keine
    RCU-6091:Validierung von Komponentenname/Schemapräfix nicht erfolgreich.
    Dropping OPSS schema...
    Befehlszeile wird verarbeitet...
    Utility für das Erstellen des Repositorys - Voraussetzungsprüfungen werden ausgeführt
    Globale Voraussetzungen werden geprüft
    RCU-6013:Das angegebene Präfix ist nicht vorhanden. Vorhandene Präfixe sind: Keine
    RCU-6091:Validierung von Komponentenname/Schemapräfix nicht erfolgreich.
    Component is already dropped
    Dropping APM schema...
    Befehlszeile wird verarbeitet...
    Utility für das Erstellen des Repositorys - Voraussetzungsprüfungen werden ausgeführt
    Globale Voraussetzungen werden geprüft
    RCU-6013:Das angegebene Präfix ist nicht vorhanden. Vorhandene Präfixe sind: Keine
    RCU-6091:Validierung von Komponentenname/Schemapräfix nicht erfolgreich.
    Component is already dropped
    Dropping BIP schema...
    Enter sys user password : stty: Standardeingabe: Das Argument ist ungültig
    stty: Standardeingabe: Das Argument ist ungültig
    Verify : stty: Standardeingabe: Das Argument ist ungültig
    stty: Standardeingabe: Das Argument ist ungültig
    Common components home from environment is /u02/app/oracle/em12c/oracle_common
    Befehlszeile wird verarbeitet...
    Utility für das Erstellen des Repositorys - Voraussetzungsprüfungen werden ausgeführt
    Globale Voraussetzungen werden geprüft
    RCU-6013:Das angegebene Präfix ist nicht vorhanden. Vorhandene Präfixe sind: Keine
    RCU-6091:Validierung von Komponentenname/Schemapräfix nicht erfolgreich.
    Is it not possible to delete the existing object with sqlplus, so that the installation process doens´t stopped with this terrible error message above?
    So i don´t know how to get a working Enterprise Manager 12c installation, hope anyone can help me in this issue.
    Kind regards
    ACID25
    Edited by: ACID25 on 24.01.2012 02:26
    Edited by: ACID25 on 24.01.2012 06:10
    Edited by: ACID25 on 24.01.2012 06:10

  • Customize menubar clock and date in NOT possible from 10.6

    it was very simple in 10.5 but from 10.6 there is NO way to customize (without other programs) the date... for example: mar 15 apr @ 15:30:20
    And I saw that is not possible to change a single point in colon (10.15.13 or 10:15:13)
    No suggestion?

    I've try but with SL is not possible to edit the file com.apple.menuextra.clock.plist. When you try with editor and save it it return as original and nothing changed in menubar...
    The only thing that I desire is the possibility to change the date/clock as in Leopard 10.5

  • Period 000 failing data load when using formula FISCPER_CALMONTH

    Hello all,
    I am having issue with my data loads from yesterday, I am using this formula to get calendar month FISCPER_CALMONTH( FISCPER, FISCVAR, FISCYEAR, 0 ).
    But my data loads fail when the FISCPER is 2008000 at this formula with error message
    "An error occured in a function of the formula
    Message no. RS_EXCEPTION000"
    We are using the fiscal year variant N6, is there any other setting that we need to do on BW side.
    Thanks in advance

    Hello Manfred,
    This is what my table T009B looks like for N6 variant, so how do I modify this ?
    Fi.Year Variant Year Calendar month Calendar day Posting period Year shift
    N6              0000 01             31           007            0
    N6              0000 02             29           008            0
    N6              0000 03             31           009            0
    N6              0000 04             30           010            0
    N6              0000 05             31           011            0
    N6              0000 06             30           012            0
    N6              0000 07             31           001            +1
    N6              0000 08             31           002            +1
    N6              0000 09             30           003            +1
    N6              0000 10             31           004            +1
    N6              0000 11             30           005            +1
    N6              0000 12             31           006            +1

  • Deleting the Master Data is not possible

    hai
    Im loaded the Master Data .
    I want to delete the Master Data. So how can i delete ??
    Im trying to delete Master Data by context menu of the Master InfoObject .But im unable to delete the master data .
    I heard that it is big issue.
    So what can i do for deleting the master data.
    pls tell me
    rizwan

    hai all
    Thanks for quick reply .
    I deleted the data from InfoCube and ODS .
    Im trying to delete the master data attribute data by context menu of master infoobject . But it is says that "Not all master data can be deleted".
    I looked at the help from that message .It says that i need to go SLG1 transaction and then delete like that
    But i dont have authorization for that transaction(SLG1).
    So plese tell me what i ahve to do for deleting the master data .
    txz
    rizwan

  • How Offiline Data loading is possible from MS Access DB to Oracle DM

    HI All,
    I am new to Oracle.
    I am trying to migrate few tables from MS Access DB to Oracle DB (10g)
    I have used the migration utility from the Sql Developer tool.
    I was successful in creating the schema and also transferring the data for tables.
    But if my data in Access DB is updated everyday then how am i suppose to link this to newly created oracle tables?
    Is there any way to do this?
    And if i want to load the Oracle tables offline using "Generate Offline Data Move Scripts" option in sql developer then how do i do it?
    I tried using the option "Generate Data Move Scripts" right click option on converted object then the utility created few files on my local machine.
    I am not able to make my way fwd.
    Please help me.
    regards,
    Sushil

    Hi Sushil,
    I will try to address each of your questions:
    Q: "if my data in Access DB is updated everyday then how am i suppose to link this to newly created oracle tables? Is there any way to do this?"
    A: Depending on your reasons for maintaining the use of the MS Access database, you have two options.
    1. lf you are continuing to use the MS Access database because the application front end is MS Access forms & reports then you could just create linked tables to the newly migrated Oracle tables. Doing so will mean that any data modified via the frond end forms & reports will be saved directly in the Oracle database.
    2. If you wish to continue saving data to the MS Access database, then transfer it to the Oracle database, then you can just use the "Migrate Data" option in Oracle SQL Developer Migration Workbench to carry out this task. You just need to ensure that you've an open connection to your migration repository, and have the converted model for the migrated database. You will then just transfer the data online, like you have already done.
    Q: "And if i want to load the Oracle tables offline using "Generate Offline Data Move Scripts" option in sql developer then how do i do it?"
    A: To migrate your MS Access data offline, you need to do the following:
    1. Run the Exporter tool for MS Access, and select the "Export for Oracle SQL Developer" option. On the second screen of the tool, browse to the location of your MDB file, provide a location for the output directory and ensure you select the "Export Table Data" option before you click the "Export" button. This option generates a .DAT file for each table containing data in your MDB file.
    2. In Oracle SQL Developer, once you have carried out your migration, select the Migration > Script Generation > Generate Data Move Scripts menu item and select the Converted Model to generate the scripts for. An "MSAccess" folder will be generated in the path specified in the "Generate Offline Data Move Files" dialog.
    3. Navigate to the "MSAccess" folder generated in step 2, and this folder should contain a "oracle_ctl.bat" file, which
    for your converted model.
    4. Edit the "oracle_ctl.bat" file and update the script to replace <Username>/<Password> with the actual username/password combination required to connect to the migrated schema e.g. for a migrated Northwind database, this combination would be northwind/northwind. Save the changes to the file.
    5. Copy the .DAT files generated in step 1 to the /MSAccess/Oracle folder. The .ctl files refer to the .DAT file in order to load the data into Oracle using SQL*Loader.
    6. Open each of the .ctl files and check the file name referenced on the 2nd line of the file e.g. infile '[Categories].null', where the file name is "Categories.null". The ".null" part must be updated to ".dat". This is a known issue and a fix for this will be available in a future release of the Oracle SQL Developer Migration Workbench. Save the changes to the .ctl files.
    7. Open up a Command Prompt & navigate to the /MSAccess folder, and run the "oracle_ctl.bat" file to load the data into the Oracle database tables. If you experience any issues during this process, check the output in the command prompt & try to resolve any reported issues. If you are unable to do so, please refer to the Migration Workbench forum - Database and Application Migrations If you cannot find a solution from the existing threads, please post a new thread, giving the full syntax of any reported error messages.
    I hope this helps.
    Regards,
    Hilary

  • Initialize delta without data transfer not possible

    Hullo,
    I want to switch the upload procedure for an ODS from full to delta. For I have researched SAP Note 689964 and executed the program RSSM_SET_REPAIR_FULL_FLAG for the ODS-object and datasource. It successfully modified the request and set the 'REPAIR_FULL' flag.
    Now I want to change the InfoPackage from Full update to Delta. According to the note I have to perform an init simulation, my problem is that the option initialize delta without data transfer is in display mode only (i.e. it's gray and I cannot select it).
    The InfoSource in question is "0HR_PY_1". I've checked several others and with some it is possible to select the initialization simulations and with others it's not.
    My questions are a) Why is it this option grayed out? and b) What can I do to enable the selection of this option?
    Any help is appreciated.

    Hullo AK,
    thanks for pointing out that note, sadly it's for "0HR_PY_PP_1" and not "0HR_PY_1".
    However it lead us to note '611199'...
    <b>Symptom</b>
    Some attributes of the following DataSources are not defined.
    0HR_PY_1 DataSource:
    - Commit after initialization phase
    - DeltaInit Simulation
    0HR_PY_PP_1 DataSource:
    - Commit after initialization phase
    0HR_PY_PP_2 DataSource:
    - Commit after initialization phase
    <b>Other terms</b>
    PXDW, extractor, posting transfer, settlement, PCPO, PCP0
    <b>Reason and Prerequisites</b>
    The SAP settings for the DataSources are incomplete.
    The following attributes should be set:
    0HR_PY_1 DataSource:
    - Commit after initialization phase: no commit
    <u>- DeltaInit Simulation: Mode is not supported</u>
    0HR_PY_PP_1 DataSource:
    - Commit after initialization phase: no commit
    0HR_PY_PP_2 DataSource:
    - Commit after initialization phase: no commit
    <b>Solution</b>
    Import the corresponding Support Package into the Plug-In Releases 2003.1 and 2002.2 and copy/activate the DataSources in the plug-in system again.
    If the correction is imported, you can <i>no longer select the "DeltaInit simulation"</i> option for the delta initialization of the <b>0HR_PY_1</b> DataSource/InfoSource.
    As long as you have not imported the correction or you are using an even older plug-in release, you should never select the "DeltaInit simulation" option during the delta initialization for the 0HR_PY_1 DataSource/InfoSource. <b>The 0HR_PY_1 DataSource does not support this mode.</b>
    The 0HR_PY_1 DataSource only supports the delta initialization (without the DeltaInit simulation) and subsequent delta calls.
    Sadly enough, not what I wanted to read, but well at least I now know that I shouldn't look into this solution anymore.
    Again, thanks for your help.

  • Formula Variable for Date/year not possible

    Hi, I have a query where I want to create a formula variable for a year that I can use in a user exit to populate other variables.  When I go to create a formula variable there is not option for a date or year variable.  I only see Amount; Quantity; Price; Number.  Is it possible just to create a formula variable for a year input without having a year time characteristic in the query?
    Thanks!

    I just ended up creating a Formual Variable as a number.  Thank You