Hi
Can you please let me know the relevant configurations to be done for automatically populating Move In Meter Read from historical read.
I have already done configurations at "Define Control Parameters for Meter Reading Data Processing" but still Move In read is not populating automatically.
Regards
Sat
Thanks for your reply but I have cheked SPRO setting the suggested check box is already uncheked.
I beleive the setting you have suggested is meant for default meter reading during move in but my problem is automatic creation of meter reading order with reason 01 during move in
Similar Messages
-
Automatic creation of meter reading order with RR 01 after move in
Hi Experts,
I am working with DM module of SAP ISU. Currently I am facing a problem that after move-in a periodic order with RR 01 is created automatically by the system.
Ex: Move in date is 01.01.2010. Monthly Portion is used with Schedule record 01.01.2010, 01.02.2010, 01.03.2010, 01.04.2010 and so on.
If current system date is 20.07.2010 then Meter reading order is created automatically by the system for sch MRD 01.08.2010.
Please let me know how to overcome this problem
Thanks in advance.Thanks for your reply but I have cheked SPRO setting the suggested check box is already uncheked.
I beleive the setting you have suggested is meant for default meter reading during move in but my problem is automatic creation of meter reading order with reason 01 during move in -
EL32: Automatic monitoring of meter reading results
When we updated to ECC6 year ago, the transaction EL32 stopped functioning. We fill in the parameters and no report is generated - nada, zilch, null.
Is the transaction not supported in ECC6? If so, is there a replacement transaction and what is it? El32 had several parameters available. Is any functionality of EL32 available elsewhere in another transaction? What is/are it/they?
Are we now doomed to code our own programmes to replace EL32's functionalities?
Thank you to anyone who can help.
mkiHI,
EL32 still runs in ECC6.0 and we have not doomed to code our own programmes. So cheer up.
Please check your configurations
SAP Customizing Implementation Guide -> SAP Utilities -> Device Management -> Meter Reading -> Basic Settings -> Define Automatic Monitoring of Meter Reading Data
Or the table TE935
Hope this helps.
Regards,
Manish
Edited by: Manish Bisht on Jul 9, 2009 10:42 AM -
Move in -Move out and Aperiodic meter reading order, No auto service Ord
Hi ISU Experts,
I have a following problem in ISU,
When create a Move In or a Move out, the system should automatically create a Meter read Order and a Service Order in the Background.
Same case is applicable for the Aperiodic meter read order, whenever I create a Aperiodic meter read order, the system should create a service order/ notification automatically in the background,
As mentioned above, In both the cases no service order/notifications is getting cretaed.
I have maintained the SPRO settings for Aperiodic meter reading and for Move in and Move out , the service order creation checkbos is checked.
Please anybody can throw some light, help me out what may be the problem, or any other SPro settings are to be maintained, any enhancement has to be done.
Your inputs will be highly appericiated .
Best Regards
SureshHi,
I am stuck with the same issue. I have checked the check box to create service order/notification from the meter reading order. Please let me know if you have found any resolution
Thanks,
Dhana -
MRO and Meter Read report and reconciliation
Hi,
I am creating Meter read orders for all MRU's in a portion and need to reconcile the number of orders created and after the read results have been received, i again need to check for how many orders reads have been received and how many are still open.
What is the standard way of doing this. I am aware of using EABL and EABLG. Will again need to understand what is a better way.
Thanks,
Monis Shakeelwe have a custom report which counts the number of orders, & results every day. After a few days the orders are filled (mostly) & business processes monitor the outstanding open orders.
The report is based on the schedule records (TE417 & TE418) as well as the meter reading results tables (EABL/G)
Alternatively: transaction EL32 can be used to monitor meter reading data.
SAP Utilities --> Device Management --> Meter Reading --> Basic Settings --> Define Automatic Monitoring of Meter Reading Data
However we've never used this functionality so I have very limited experience with its subtleties.
user exit EDMLADUE is utilized here.
I'd be interested in any 'better way' you end up pursuing. -
DM - Meter Reading Workflow functionality
Hi all,
I have a customer's requirement that the estimated MR should be "corrected" automatically in case the next actual MR arrives and it is less then the estimation done before.
Can anybody help me via the customizing and the development (if any required)?
I have found the Customizing section Define Automatic Monitoring of Meter Reading Data, that works in co-operation with the function module EXIT_SAPLEL01_020, but I am not sure if this is the recommended way of solving this problem.
Thanks in advance for your feedback, regards,
Bou.LisHi Bou.Lis,
Standard SAP Triggers the event ASSESSED in the Business object - ISUCONTRCT. Use this to assess the meter reads and estimate the reads.
Obviously you may also need to cancel the billing documents if you are adjusting the meter reads for the period billed. In that scenario you can use BILLDOCAUT -> BDOCSFORREVERSAL and BILLDOCAUT -> ADJREVERSETAB.
For re-estimation you can leverage using the FM ISU_ACTION_ASSESSING. This FM estimates for all the registers, so you might want to customize and re-estimate only for implausible meter reads registers.
I would recommend working with a solid workflow developer who has IS-U knowledge.
Hope this helps.
Sai -
For few devices Meter Read order 09 information created automatically.
Hi,
In our one of the clients ISU system for EVC meters two Information read Orders are automatically created few days before every 01 order creation for the particular device. Please provide the information due to what the Information Read order 09 is created .
With RegardsCheck Meter control group is filled in register data of device. Control group allows to create multiple meter reading order in between periodic billing with meter reading reason
09.Please make control data blank from device modification transaction if
interim meter reading order is not required.
Thanks,
Laxmi. -
is there a way to set Thunderbird to automatically move mail I have read into an old mail folder?
I would start by creating a filter that looks like the one in the picture, but if you were run the filter automatically when getting new mail, it might behave oddly if new mail arrives while you're reading a message.
http://kb.mozillazine.org/Filters_(Thunderbird)
Another approach could be to use the Age in Days + is greater than + 1 criterion in the filter. -
Is there a way to automatically move mail from one folder to another?
Is there a way to periodically, automatically, move mail from one folder to another?
For example, I'd like to move mail from one of my IMAP/Archives folders to my MyMac/Archive folder and I'd like this to happen without intervention.
Can this be done?I'll try to be more specific.
When I'm done with an email, I archive it.
Because I have multiple email accounts, this results in emails in multiple Archive folders (one per account).
I'd like to have these automatically all moved into one (on my Mac). -
Previous Meter Reads and Usage are not correct after meter Proration
It seems that during proration there are two meter reading available the one with the Meter Reading type as 03 ( Automatic Estimation ) and other is Meter Reading type 01 - MR By employee that is being retrieved. The 03 reading type seems to be the reading after the proration and the o1 reading is the reading done before the proration . The reads are coming out on our invoices incorrectly. Usually there will only be one Meter reading to be picked up. but it seems do proration it splits meter into 2 entries. The entry with with metering type 01 has the correct previous and current meter reads but incorrect usage. The entry with meter read 03 has the incorrect previous meter read and correct current meter read but incorrect usage. Our print work bench generated fiction is calling SU_DB_ERCHZ_SELECT_BILL_NEW to retrieve the values but the values that it retrieves are not correct., The second records is being put on the invoice. The form that exist in the SU_DB_ERCHZ_SELECT_BILL_NEW is called db_erchz_select_join and is used to retrieved the usage and meter reads.. This information is then passed to out user exit.
The previous meter read should be 5,073,998 and the usage should be 7500
Service Meter No. Previous Read Current Read Usage
Water 750009 5,092,748 5,148,998 56250Try resetting the PMU…
http://docs.info.apple.com/article.html?artnum=14449
… and then subsequently calibrating your battery…
http://docs.info.apple.com/article.html?artnum=86284 -
Cursor automatically moves to the address bar when I open a new page
Ever since I installed Firefox 4, when I open a new tab the typing cursor automatically moves to the address bar instead of the search engine bar. I have the tab mix plus addon. A solution appears to have been found for the same problem with the newtabhomepage addon, but since the two are not compatible with each other, I don't want to switch addons. Is there any way I can fix this?
Thanks!If your using the 'New Tab Homepage' extension then this happens when you upgrade to Firefox.
Open up Firefox and click on Ctrl+Shift+A to bring up the add on/extensions menu. Have a look in the Extensions bit for an Extension that has a version no of 0.4.3. if you have it then it needs uninstalling. Then download the new file from the mediafire link
http://www.mediafire.com/?v1113g9noytswdv
You will then be asked if you sure you want to install it and drag it on to the extensions page in Firefox.
Once installed restart Firefox. Once restarted your homepage will load whenever you start a new tab. -
Meter Reading date – estimating EL30
Morning,
Do you know how can I change the meter reading date when I run the estimation process through transaction EL30?
See the problem.
This customer has a custom estimation development. But, I see that meter reading date in the estimation enhancement is set with the scheduled meter reading date.
However, I would need to change this date to the system-date when the estimation is triggered through tx. EL30.
Is there any enhancement before the estimation module, to change the meter reading date automatically?
Thanks.Hi,
use function module ISU_DB_TE418_SELECT_DAT_TUR_NX or ISU_DB_TE418_SLCT_N_ADATSOLL_T for the next date and ISU_DB_EANL_SINGLE_ALL_TS to get the MRU of the installation first.
KR
Uwe -
EL 27 Correction of Implausible Meter Reads
Hi All,
I am trying to release impalusible Meter Readings via TCode EL27, by entering a Premise. Two things are happening:
1. Direct Release of MR occurs . (no idividual correction screen opens)
2. Individual Correction screen opens. (no direct release)
I debugged quite a few cases and have reached a few conclusions:
FOR INDIVIDUAL CORRECTION SCREEN TO OPEN:
Pre-requisite = Value of ORIGIN_ESTIM = 6
With this pre u2013 requisite, when there is 1 installation, with 1 register then in EL27, individual correction screen will open and MRu2019s can be edited.
FOR DIRECT RELEASE:
Apart from the above prerequisite & condition, FOR u201CANY OTHERu201D CONDITION, the correction screen will not open and MRu2019s cannot be edited.
Value of Origin_estim can be viewed on the individual correction screen "Execute Correct Implausible Meter Reading Results" screen; Forecast data tab--> Origin
Values of Origin:
1 - Past MR results
2 - Period Consumption
3 - Reference value
4 - Proration
5 - External Determination
6 - Estimation not Possible
Also, is this phenomenon of direct release/ correction screen display DEPENDENT on MR REASON???
Thanks in advance,
Prajakt Dhumal
Edited by: prajakt k dhumal on Oct 28, 2010 9:28 AMHello,
It should be possible to get to the correction screen by selecting the line you want to correct an click on 'correct'...
You could skip this and release directly but there should be always an option to go into the correction screen as long as the meter reading is "still implausible".
Only time this happens is if the meter reading is automatically plausible e.g. if no extrapolation was possilbe. You should get a
message about this.
It will only enter the correction screen if there is an "invalid meter reading result". If it is valid now (without doing changes) there is no need for correction anymore therefore it is released immediately.
The correction screen is not build to handle more than one meter reading at a time. Hence there is no way you correct more than one meter reading at the same time i.e. count_eabl >= 2.
Hope this is helpful ...
Regards
Olivia -
I have put my Michel Thomas french lesson cd's onto my ipod but when each track finishes it does not automatically move onti the next track. I have ticked the option "part of a gapless album".
naturescape_peopletecture wrote:
and made a "brush-arrowhead" as you can see in the image below.
To answer your questions need to know who you made a brush arrowhead.
The default arrowhead are specifically designed with a bounding box designed to not have this problem, and even have this option
You are wanting arrows in the middle of a line so would recommend a scatter brush.
And a stacked appearance with 2 strokes.
Though you may not like who the dashes are lining up here so if you go back to the first method I show, you can do a few paths too get this. -
T-code el31(Meter Reading data) output modification
Hi all,
i am working in the sap isu industry. I just want to know whether the output screen of the standard transaction code el31 can be modified or not.
if yes how? I wanted to add one more field to the ALV output of the el31 Installation-Meter reading result.you can try with user exit
http://www.sap-img.com/abap/a-short-tutorial-on-user-exits.htm
http://www.sapgenie.com/abap/code/abap26.htm
http://www.sap-img.com/abap/what-is-user-exits.htm
http://wiki.ittoolbox.com/index.php/HOWTO:Implement_a_screen_exit_to_a_standard_SAP_transaction
http://www.easymarketplace.de/userexit.php
http://www.sap-img.com/abap/a-short-tutorial-on-user-exits.htm
http://www.sappoint.com/abap/userexit.pdfUser-Exit
Transaction Code - EL31 Manual Monitoring
Exit Name Description
EDMASSES IS-U: User-Defined Validation for Overestimation
EDMEL231 IS-U: Meter Reading Result - Incorporation of Subscreen
EDMFOLUP IS-U: Determine follow-up actions during MR result entry
EDMLELAE IS-U: User Exit Too Static. Evaluation of Evaluated Data.
EDMLELDE IS-U: Dependent validations based on user exit
EDMLELSV IS_U: User Exit After Saving Meter Reading Results
EDMMR002 IS-U: Change to Gas Date During Meter Reading Result Entry
EDMMRRES IS-U: Change readings during upload (before validation)
EDMMRSTR IS-U, Display Additional Fields for Street Route Maintenance
EDMSUPBI IS-U: Automatic Suppression of Billing/Deac. Meter Readings
No of Exits: 10
Rewards if useful.......................
Minal
Maybe you are looking for
-
How to use a Logical Database in Function Module.
Hi Experts, I want to use a logical database in a Function Module to fetch data from a standard SAP table into a Internal table for certain filter conditions. How can I get get this done???? I called LDB_PROCESS FM in my FM, but I could not figure ou
-
Is there a way to save a restored session (without opening it) to bookmarks?
I kinda get carried way with opening tabs, like I'll have 50-200 open at any time. And you can imagine what it's like when Firefox crashes and you attempt to restore a crashed session - all the tabs reopen at the same time. Is there any way to save a
-
USER-EXIT / ENHANCEMENT / BADI -- Material Valuation Class (MBEW-BKLAS)
Hi, I m looking for any user-exit, enhancement or BADI which is triggered while executing MIGO!!!! . For example, for good movement 101related to a purchase order. If MIGO item (material) have batch management we have to inform the batch number (ma
-
How to undelete an icon?
My Good email icon went bye bye. Apple suppose to be "so easy to use" don't provide a way to restore an icon? Extremely urgent. Please help !!! Thanks in advance
-
Export Catalog content to R12 instance
cancelled post Edited by: Imperialist on 10-Sep-2010 08:23