BackinBean scope is an unknown variable

JDeveloper 11.1.1.2.0
1) I have created unbounded task flow adfc-config with method="methodCall2":
<method-call id="methodCall2">
<method>#{backingBeanScope.MojeBina.zkopiruj}</method>
<outcome id="__21">
<fixed-outcome>test</fixed-outcome>
</outcome>
</method-call>
2) than I have registered managed bean in adfc-config task flow :
<managed-bean id="__16">
<managed-bean-name id="__14">MojeBina</managed-bean-name>
<managed-bean-class id="__15">Fa.view.backing.FakturyMain</managed-bean-class>
<managed-bean-scope id="__13">backingBean</managed-bean-scope>
<managed-property id="__18">
<property-name id="__17">table1</property-name>
<property-class>oracle.adf.view.rich.component.rich.data.RichTable</property-class>
<value id="__19">#{table1}</value>
</managed-property>
</managed-bean>
3) when I am trying to fill in field Method in methodCall2 by expresion builder by value #{backingBeanScope.MojeBina.zkopiruj} I get immediately red underline and blue hint: backinBean scope is an unknown variable. What I am doing wrong ?
Thanks for the advice
Petr

Nothing at all!
It's just that the backing bean scope can't be evaluated at design time. This scope is only available at runtime. JDev tries to evaluate the expression, gets an error (because the bean is not present at design time) and shows the red underline (see http://thepeninsulasedge.com/frank_nimphius/2010/03/09/gotchas-when-using-memory-scope-prefixes-in-el-to-access-managed-beans).
You can switch off this warning, but I can't remember how. I'll look into this.
Timo

Similar Messages

  • What is the scope of implicit loop variables?

    Hi,
    I'm facing some strange error from the ABSL editor (syntax checker).
    In ABSL the loop variables are implicit and don't have to be declared in the head section of the script.
    My question now is simple: How is the scope/visibility of such loop variables specified ?
    There's a complete code snippet below.
    In line no.9, there's the first time use of implicit loop variable 'task_inst'.
    Because of type inference, it will be typed as MasterDataWanneBe/Tasks (which is my own BO type).
    In line no.20, I want to use the same variable name in a different loop, outside the parenthesis/scope of the first first use.
    Now the ABSL syntax checker complains about incompatible types (see code snippet)
    Thus the type inference should result in the, (lets say 'local') type Project/Task, which is the one I was querying for.
    To me it looks like, that loop variables implicitly get a global scope (hopefully bound to this ABSL file only).
    I would like to see the scope/visibility of loop variables restricted to the parenthesis.
    In other words only inside the loop.
    Hint
    I heard (from little sparrows), that local variable scoping is not possible because of underlying
    generated ABAP code. If so, than it would be helpful to print warnings, in case of types are compatible
    but used in different scopes. Think about the unintended side effects.
    import ABSL;
    import AP.ProjectManagement.Global;
    var query_tasks;
    var query_tasks_param;
    var query_tasks_result;
    foreach (empl_inst in this.Employees) {
         foreach (task_inst in empl_inst.Tasks) {
             //   ^^^^^^^^^  first time use
              task_inst.Delete();
    // ===========================================================================
    query_tasks = Project.Task.QueryByResponsibleEmployee;
    query_tasks_param = query_tasks.CreateSelectionParams();
    query_tasks_result = query_tasks.Execute(query_tasks_param);
    foreach (task_inst in query_tasks_result) {
          // ^^^^^^^^^ Error: 4
          // The foreach loop variable is already inferred to an incompatible type:
          // Node(MasterDataWanneBe/Tasks). Expected Node(Project/Task)

    Yes, variable declarations in ByD Scripting Language indeed have (snippet) global visibility. In the FP 3.0 release the variables can be declared anywhere in the snippet (not only in the beginning, as with FP 2.6), however still not within code blocks, i.e. within curly braces ({}). Therefore variable name shadowing is still not supported and because of the global visibility of variables they cannot be reused for a different type, later in the same snippet. This is because of the statically typed nature of ByD Script, despite the type inference convenience.
    Kind regards,
    Andreas Mueller

  • Unknown variable or property name 'ReportFilePath'. Error accessing item 'Runstate.Root.Locals.ReportFilePath'. in TestStand

    Hi all.
    I was using Teststand 4.2 up to last week and upgraded to TS 2013. In 4.2 I was using the following to get the location of the teststand report:
    Runstate.Root.Locals.ReportFilePath
    but with TS 2013 this no longer works.. is the following error:
    Unknown variable or property name 'ReportFilePath'.
    Error accessing item 'Runstate.Root.Locals.ReportFilePath'. in TestStand - Get Property Value (String).vi->
    I've tried the following now with no success:
    RunState.Root.Report.Location
    So my question is how can I get the location (path) of the report file during test programmatically please?
    Please find enclosed a screenshot of the report config:
    Solved!
    Go to Solution.
    Attachments:
    TS_ReportConfig.png ‏42 KB

    Shashidhar,
    Thanks for your help! With your tips, I finally got it to work. For anyone else trying to modify report names based on user input after the sequential process model sets the file name path I will re tell what I did:
    Edit the Ni_RerportGenerator.seq plugin found in C:\Program Files (x86)\National Instruments\TestStand 2014\Components\Models\ModelPlugins\
    You go into this file and add the step higlighted in Blue at that same location. Please see the expression I typed in the expression box. Setting Parameters.ReportOptions.NewFileNameForEachUUTStatus to true forces re-evaluation of the report name at the end of the sequentialmodel.seq.
    Then you add a FileGlobal in the sequenatialmodel.seq. I called my FileGlobal ReportFileName
    Then I added an expression in my test sequence that modified the the new FileGlobal I created:
    Finally I updated the report options (Go to Cofigure>Report Options > Report File Pathname and under File/Directory Options select "Specify Report File Path by Expression" and I entered my expression. It appears that you can disregard the evaluated report file path error (box below) because your pathname won't be generated until run-time.
    This worked well for me hopefully it will for others. 
    Thanks,
    Marco

  • "sCode=0xf​fffbc66: Descriptio​n: Unknown variable or property name 'ReportSty​le'. Error accessing item 'ReportSty​le' when trying to optn the ReportOpti​ons in TestStand 4.0.

    I get the error "sCode=0xffffbc66: Description: Unknown variable or property name 'ReportStyle'.  Error accessing item 'ReportStyle'. when trying to load the ReportOptions in TestStand 4.0.
    Has anyone seen this before?  If so how can I get around it as I will need to disable Report Generation for this system.
    Thank you

    Hello,
    I am not 100% sure how I resolved this issue as it was a few years ago.  However, I have attached the TestStandModelReportOptions.ini file that I used - hope this helps you.
    Attachments:
    TestStandModelReportOptions.ini ‏5 KB

  • Error Message in Terminal: unknown variable 'datadir=/usr/local/mysql/data'

    Hello,
    I'm on a Mac Pro Quad Core Intel Xeon (64-bit) using OS 10.6.4. I have mysqlnd 5.0.5-dev - 081106 - $Revision: 289630 $ and PHP Version 5.3.1.
    I have also installed phpMyAdmin 3.3.1 and have set up the relations tables in a pmadb within mysql; created a new database with tables; and created some new users. I am able to access and use mysql via phpMyAdmin.
    But now I am unable to login to mysql via the Terminal command:
    mysql -u root -p
    which now returns an error message of:
    /usr/local/mysql/bin/mysql: unknown variable 'datadir=/usr/local/mysql/data'
    my.cnf file reads:
    [mysqld]
    datadir=/usr/local/mysql/data
    socket=/var/mysql/mysql.sock
    #skip-grant-tables=1
    [client]
    datadir=/usr/local/mysql/data
    socket=/var/lib/mysql/mysql.sock
    and I can see the data directory in that location when using the Terminal.
    My questions:
    1. Is this related to anything I have done in setting up phpMyAdmin (tables, users)?
    2. Is this a permissions problem with the directory named /usr/local/mysql/data?
    Currently, the permissions and ownership are this:
    drwxr-x--- 11 _mysql wheel 374 Jun 29 12:10 data
    3. Is this a problem from upgrading to 10.6.4 recently?
    4. Is this a my.cnf problem?
    I would really like to be able to do things in the Terminal with mysql in addition to using phpMyAdmin.
    Many thanks for any help on this.
    Best,
    Shelley

    Shelley Schreiber wrote:
    Thanks for your suggestion, etresoft, but this was not helpful, I'm afraid. Removing datadir=/usr/local/mysql/data did not work. And prior to using phpMyAdmin, I was able to login via Terminal with this in place.
    Try removing my.cnf. It isn't required and seems to be giving you problems.
    Also, the mysql socket value is what comes with new Macs with Snow Leopard.
    MySQL doesn't come on any new Mac except with Snow Leopard Server. I think we've had this conversation before and came to the conclusion that you don't have the server version, just a jacked up client.
    I am noticing that the Terminal error message I get is saying:
    /usr/local/mysql/bin/mysql: unknown variable . . .
    whereas the data directory path is /usr/local/mysql/data
    There is no data directory in /usr/local/mysql/bin/mysql
    The program that is reporting the error is is /usr/local/mysql/bin/mysql.
    My MySQL installation does not have a my.cnf file. It does have a number of example cnf files that I could use if I wanted to jack up my installation. None of them have a "datadir" value in them. If you don't want to get rid of my.cnf altogether, the just get rid of all of the datadir values inside it.

  • Step_description unknown variable error in built operator interface

    I'm getting the following error when I execute a seq. from a built LabVIEW operator interface:
    Error evaluating expression
    Unknown variable or property name 'STEP_DESCRIPTION'.
    Error accessing item 'STEP_DESCRIPTION'.
    Some searching is leading me to an issue with the localization languages files? Not sure what exactly.
    Message Edited by Michael Aivaliotis on 11-06-2007 01:09 PM
    Michael Aivaliotis
    VI Shots LLC
    Attachments:
    1.png ‏10 KB

    Here is a guess: try right clicking on the step list and select a different step list configuration. If the problem goes away, then your current step list configuration has a column specified by expression and there is a problem with the expression.
    Message Edited by James Grey on 11-06-2007 03:14 PM

  • [HELP] Error, Unknown variable or property name '', error. No Details???

    Our production team ran some of our TestStand software when it froze.  Upon exiting the report file contained only one error:
    “Error, Unknown variable or property name ''. [Error Code: -17306, Unknown variable or property name.]”
    This has not happened before with this test sequence.
    Now I have seen this before, during development of other TestStand projects, but there are usually details of the unknown variable in the error.  This one just has empty quotes!  There are around twenty sequences called in this software.  Is this a rouge error, a symptom of the freeze, or do we have an unknown variable issue in these sequences?
    Christopher Povey
    Senior Test Systems Engineer for BAE Systems.

    Hi Christopher,
    As you say as part of the Error Message you should of had the Variable name.
    With this freeze and if you had to force exit of the TestStand, it would seem that to get any report at all you must be doing some sort of 'On the Fly' reporting. If so, can you pin point what the test sequence was doing to try to identify the cause of the freeze.
    Maybe you are obtaining the variable name dynamically and because of the crash this value was not obtained and therefore you were passing an empty string. Hence no variable name in error message.
    Regards
    Ray Farmer

  • Why does DB_PLImpotExportProperties throw "Unknown variable or property name. (Error = -17306)"?

    When I run GenericImportExport.seq, the call to  DB_PLImpotExportProperties brings up the Import/Export dialog. When I copy that step into my existing sequence, the error "Unknown variable or property name. (Error = -17306)" is thrown. I can see no difference between the two. They also appear to be running in the same environment.
    Any suggestions?
    Solved!
    Go to Solution.

    So this was bothering me enough that I went back and recreated the problem. I cannot even call the entire sequence without getting this error.
    I added a step to my test sequence that makes a call to the sequence GenericImportExport.seq in a separate file (where it was installed). Right-clicking on the the step and selecting "Run Selected Steps" causes the subject error.
    I CAN use the tool menu "Import/Export properties..." or open the sequence itself and run ImportExport without a problem.

  • 'Unknown variable'-​error in TSIviStepT​ype: Uses the german bolean value 'Falsch' instead of 'false'

    Hi
    I had to install MSVC onto a working test system. This is a PII/450 with 450MB RAM, running a german W2kSP2 and NI-SW from the english DevSuite Prof Test Edn, amoung others LV7.1, TS3, Switch Executive (SE) 2.
    I had to install a german MSVC6 for debugging purposes. Its installer asked me for permission to replace some ressource files with german ones, which I -of course- denied. Nevertheless after this installation my TSIviSteps generate an error with a language-related problem:
    Error executing substep 'Post'.
    An error occurred calling 'RunStep' in 'ISubstep' of 'TestStand Ivi Step Types'
    An error occurred while executing the step.
    TestStand IVI Step Type Error:
    An error occured when evaluating the properties of the step.
    Details: Unknown variable or property name 'Falsch'.
    Error accessing item 'Falsch'. - Wait for Debounce
    Source: TSIviStepTypes
    -17300; Value invalid or out of range.
    Any easy solution? There must be a simple ressource file to be replaced. I'd dislike the idea of re-installing TS. BTW, Re-installing all the drivers and SE did not help.

    The error you are seeing is because of a problem in the code for the TSIviSteps.dll. The code is written with Visual Basic 6.0. The error only occurs for the "Wait for Debounce" setting, which is only used for the Switch Executive Connect/Disconnect operation. Internally there is a cast of a boolean value stored in a step property to a string expression value. If the OS regional setting selects a non-English default language and the corresponding VB6xx.DLL (language resource file) is available, the MSVBVM60.DLL casts the boolean value to a localized string value. So for a German OS, if the VB6DE.DLL file is available the cast returns Falsch or Wahr instead of False or True. When TestStand tries to interpret Falsch or Wahr as a constant expression it
    errors as described. The problem exists in TS 2.0.1, 3.0 and 3.1.
    The workaround is to either remove the VB6DE.DLL language resource file or change the default language to English. We hope to fix the cast code in a future release.
    Scott Richardson (NI)
    Scott Richardson
    National Instruments

  • How to use window.confirm in a JavaScript with unknown variables

    On my delete category page the user can pick the category it wishes to delete from a dropdown list (which is generated by rows in my database).
    When the user hits the "Delete" button ths OnClick runs a JavaScript that sends the delete request to a .jsp page that handles all my insert, update and delete queries.
    <input name="delete" type="button" id="delete" onClick="post('delete');return false;" value="Delete">
    function post(actValue)
         document.MyForm.action.value = actValue ;
         document.MyForm.submit() ;
    }So far, so good. But:
    Before the site goes to this last jsp page I want a pop-up window that ask's for a confirmation of the delete-request.
    So I changed the OnClick and I made another JavaScript::
    <input name="delete" type="button" id="delete" onClick="delete('categoryName');return false;" value="Delete">
    function deleteConfirm(categoryName)
         if( window.confirm("Are you sure you want to delete: " + categorieNaam + "?") == true)
              post('delete');
              return false;
    }The problem is, when the page is loaded, we don't know yet what category the user wants to have deleted. So categoryName is unknown.
    How can I make this work?

    You have the category in a dropdown list?
    <select name="catToDelete">
    <option value="cat1">cat1</option>
    <option value="cat2">cat2</option>
    <option value="cat3">cat3</option>
    </select>
    You can use javascript attributes such as
    var toDelete = document.all.catToDelete;
    // the value it will submit
    var selectedValue = toDelete.value;
    // the selected index
    var selectedIndex = toDelete.selectedIndex;
    // the option that is selected
    var selectedOption = toDelete.options[selectedIndex];
    // the text of that option
    var theText = selectedOption.textYou should be able to extract the info you need from that I hope.
    Cheers,
    evnafets

  • Error Code 17306 Unknown Variable or Property Name " Locals.Mod​el"

    I get the above message when i run the step f(x) SetFileGlobal operator...No code module adapter is used.
    I have attached my seq file and only second and third step are erroring out..I checked the rest of the sequences they work fine. Any help is appreciated.
    Thanks
    Attachments:
    0960.seq ‏42 KB

    Hi,
    Open your sequence file in the Sequence Editor.
    Select the Sequence that you wish to add Locals to, and make this the active sequence i.e the one thats visible to you, Usually it displays the MainSequence  when first loaded.
    Select the Locals Tab
    In the right hand side of the display, there will be the variable ResultList.. This will be an empty array of Result.
    Place your cursor in this position of the display and press the Right Mouse button. You will see an a popup menu of which the Top Item is Insert Local.. If you select this you will get an other set of options which are the different types of Variables that are available to you. Select a variable type, such as a Number. This will be inserted into right hand side under the ResultList array. It will be highlight ready for you to enter the name of the variable. If you double click on the variable you will get the Properties Dialog. You will beable to a new value.
    The User Manual, should beable to explain on this.
    I would recommend trying to get on the Basic TestStand course.
    hope this helps
    Regards
    Ray Farmer
    Regards
    Ray Farmer

  • Unknown variable or property name stationGlobals.Revision

    I am having problems with a stationGlobals variable on one deployed system in the field. I stop on that step on the development system and the deployment system here in the lab and the variable exists. 
    On the system having the problem the station options was not pointing to the correct location for the stationGlobals.ini. So I had them change the cfg preference and sent them a copy of the stationGlobals.ini file. They rebooted the system but the error persists.
    Sure would appreciate your thoughts on this.
    jh

    Thanks for the post. It turns out that the .ini file was overwritten when the station options were changed on the deployment system. They were changed to alleviate the problem I addressed in my Station options not copied to deployment post.
    jh

  • Sort on an unknown variable value

    Can anyone tell me how to sort a report whether it be EVDRE or EVGTS on a derived value..
    i.e.
    Actual_Turnover, Budget_Turnover, Turnover_Variance
          *1000000,             1500000,                  -500000
    I want to sort on the variance without having it stored in the application as a member.
    The problem I have is that I am using 4.2 sp3 which is pre the evdre builder.

    As you noted in 4.2 sp3, sortcol and sort range are not part of the EVDRE.  You have two options, one is to use an EVENE fuction to sort the memberset during the query using MDX or you can return an EVDRE or EVEXP expansion and use an excel macro to sort.  The first option requires MDX knowledge and may decrease performance depending on the size of the resultset but would be returned sorted using built in webexcel refresh.  The second option would require a button (with refresh and sort macro code) and results would only be sorted when the user refreshes through the button and not the toolbar refresh.  Remember when sorting with a macro to select the entire data range and rowkey range.

  • Error code -17306; Unknown variable or property name.

    What does this error code mean in Test Stand, And what are solutions to this problem

    Hi Reiter,
    There are many reasons for this error as Nick has pointed out.
    I have attached an example illustrating a typical situation.
    One of the steps tries to read the value of a boolean in Locals of MainSequence. An error -17306 is generated if the boolean is not present.
    The first step in Main gives you the option to skip or not skip the next step in the sequence.
    The next step writes True to Locals.MyBoolean. (not this step has the option 1 - Insert if Missing)
    The following steps Reads the boolean Locals.MyBoolean.
    Hope this helps to resolve your problem
    Regards
    Ray Farmer
    Regards
    Ray Farmer
    Attachments:
    Skip_Next_Step.seq ‏29 KB

  • Error -17306 Unknown variable or property name

    I get the above error when trying to deploy from Windows 2000 to a Windows XP professional?

    Hi,
    Have you got the ProcessModel sequence file "SequentialModel.seq" on you Deployed system.
    You should find it in "TestStand\Components\NI\Models\TestStandModels" folder or "TestStand\Components\User\Models\TestStandModels" folder.
    Regards
    Ray Farmer
    Regards
    Ray Farmer

Maybe you are looking for

  • Sender File Adapter Wildcard

    Is it possible to get PI to traverse an unknown file system searching for files to drag in through the file adapter FTP ? I know the file adapter can be configured for multiple sorce directories, but can it be configured to search any directory with

  • Some comments on PDFs are not printed

    Hello, I've noticed that when making comments in Acrobat XI Pro, some of the comments are not printed as they are shown on the screen. For example, on one document I have a text box with two lines of text in it, but only the border of the text box an

  • How to use Cisco ASA5510 as an IPS

    We have a Cisco ASA5510 w ith ASA-SSM-10 module but we´d like to know how to configure it as an IPS. We have it in the same network but in a simulate enviroment 2 different network segments.

  • Can I display a double line of bookmarks on the bookmark toolbar?

    Foxfire 31.0, XP Pro, Currently I can only get 7 items in bookmark toobar, I would like about 10. Thanks.

  • COMPONENT MONITORING  in the RWB is not working /throwing error

    HI I ve recently installed a new PI 7.0 SP 18 , but my COMPONENT MONITORING  in the RWB is not working , as i click on COMPONENT MONITORING it throws an error : java.lang.NoClassDefFoundError: com/sap/aii/rwb/exceptions/HttpException , pl help thanks