BEx  Analyzer 3.x after 2004S Upgrade - Variable Screen

The variable screen has changed when using BEx Analyzer 3.x after upgrading to 2004S.  Is there an option to go back to the original version?  We are doing a "technical upgrade only" this weekend to our production system and did not want to impact our users in any way at this time.  There was a thread that started out asking about this issue but then switched to discussions about the Query Designer and the variable screen question was never answered.
Thank you for your help.

Yes, I can access RRMX.  However our users cannot.  They log on through Citrix directly to BEx Analyzer 3.x.  When I use transaction RRMX, it takes me to BEx Analyzer 2004S. 
Is there any way for our users to access the old variable screen using BEx Analyzer 3.x?  And if not, is there any documentation anywhere on the new variable screen that is being used for 3.x after technically upgrading to 2004S?
Thank you -
Ann

Similar Messages

  • BEX Analyzer not working after SAPGUI730 update

    Good day
    I really require your expert assistance with the following:
    The client has just upgraded to SAPLogon 7.30 file version 7300.3.1084 patch level 8, but they did not consider the application level and MO versions on any of the laptops.
    A few laptops are configured with Windows 8, Microsoft Office Professional Plus 2013 and Excel for 32 bit.
    Setups were run for "gui730_0-10010496: and "gui730_8-10010496".
    Everything works, except for BEx Analyzer that does not want to open at all.
    How do I fix this?
    Thanks in advance
    Cj

    Hi,
    The support for Microsoft Office 2013 is available only after BI-addon for SAP
    GUI 7.30 FEP300.
    See 1652769 - 730 GUI DVD - BEx tools - HW\SW requirements
    Have you satisfied this criteria?
    Regards,
    Michael

  • Imac not responding after mavericks upgrade- black screen

    Ever since I upgraded to Mavericks 2-3 weeks ago ....if I leave my mac for a while and then try to wake it up with a touch of mouse or keyboard, the screen remains black. The mac is still on as its warm .The only way to recover this is to :
    1. Pull out the plug - gives fresh reboot
    2. Keep the start button pressed for approx 5-10 secs, then press it again and the mac powers up...to the state it was when left ie not a fresh reboot.
    This is very annoying , has my wife yelling at me and no longer gives us the instant access from sleep we used to have ...
    Any help appreciated !
    Thanks Jon.
    I have a 27" iMac from August 2010 (ie v soon after CPU upgrade) , core i3 processor

    OK I appear to have fixed this ...after the Mavericks upgrade the screensaver was reset to loading photo's from "national geographic" which it did after a few mins...i have changed this to another option photo's of earch/space etc..now i can wake the imac from sleep immediately as before ....so now fixed !
    Jon

  • T 61 dead No bios get /post msg after bios upgrade /no screen

    hello  all , i  have  a  problem  i  had a  issue few days ago  download  bios update tools from  lenovo  site and  click  on (from laptop not bootable cd)  upgrade  when  i launch  program  it   got  hang  and  i  even  did  not  click  on  yes i  agree  for  upgrade  and  closed  that from task managed with  end task  as it  was  hanged  so  after   restart  laptop  there  no   boot  no  screen no beep  only power  ligts  on  and  when i  try  to  put  bios  bootable cd or any bootable cd it does not  get anything  just  cd rom  is  runing   but  nothing  get  or post  please help  me if  bios  corrupted  or dead what should i do  or  are there any  way to replace  bios chip etc i live in country  side  so  no  lenovo  support  here  thanks in  advance

    hi lead_org thanks for your reply   yes mate   i  did   it  also  did  try  to   remove  both  ram's and one by one  if i  take off  ram  then try to  start   it  give few beeps   but  if  put  ram back  and start   then nothing  coming  just  power  lights on and  cd rom is running  if i put any  cd  etc but  nothing  on  screen  like get or post  msg  for bios setting   etc

  • Max number of entries in the variable input list (F4) of Bex Analyzer Query

    Dear BW experts,
    When I run the Bex Analyzer query, it pops up the variable input screen.
    If I don't know the specific value of the variable, then I can click on the input help (F4) to get a list of available values.  There is a max number of entries coming back to the list.  For my BW system, it is currently returning 500 values.  For other people and SAP Help document, it could be 1000.
    My question is: Do you know where we can configure/set this max value? Is it a global setting?
    Thanks in advance for your help in this matter.
    Kevin-

    Murali & Pra,
    Thanks for both of your answers.  I think the answers that you provided are for BW 7.X version.
    It is flexible and exactly the way it should be for each user to customize a specific variable.
    I am running BW 3.5 query, and don't see the "Settings" option/button after I got the list of single values back.
    Is there a way to set this up for BW 3.5 query Analyzer?  My max value is always 500 for all variables.  Is there a place for setting this value and save for the next time.
    Any help from any BW experts is appreciated.

  • Problem-taking a long time to open Bex Analyzer

    We upgraded from BW 3.1 to BI 7.0 SP9, Front End SP 9, Patch 3, Revision 370 and have a problem when we try to access Bex Analyzer.  The response time is very poor. It can take as long as 3 minutes (or longer) for Bex Analyzer to open after we click on the Bex Analyzer option.  When we were on BI 7.0, Front End SP 7, the response time was better but since upgrading to FEP 9, the time to open Bex Analyzer from our PCs is very long. Has anyone else experienced this problem? If so, how was it resolved? Thanks

    You might want to trouble shoot with web log from BINW2004s forum topper and Front end Champ Prakash ...
    <a href="https://www.sdn.sap.com/irj/sdn/weblogs?blog=/pub/wlg/4087">https://www.sdn.sap.com/irj/sdn/weblogs?blog=/pub/wlg/4087</a>
    Hope it Helps
    Chetan
    @CP..

  • BEx Analyzer Varibale screen cancellation results in inactive buttons

    Hi All,
    In my workbook when I cancel the variable screen pop up it results in an inactive workbook. That is, after the cancellation the buttons will not work. We cannot do any operation in it. We can only work in the workbook once we enter the design mode and exit from it.
    SAP note 413448 says to upgrade patch. But it is for BW system and BW FEP version 2.0. We are on BI 7.0.
    Is there any other alternative for this problem.
    Thanks and Regards,
    Jerry

    jerryabap wrote:
    Hi Arun Bala,
    >
    > We are currently on BI 7.0 SP 20. Moreover the note does not explain the error after cancelling varibale screen.
    >
    > Any other inputs please.
    >
    > Thanks and Regards,
    Hm, Is it so. Could be some program error? As in Note 1424498 - BEx Web 7.0: Issues after Cancel in Variable Screen http://goo.gl/Dd8fw. Other option is to personalize the variables.You can check this post for more details. http://goo.gl/g4OQZ. Alternatively have you tried the following :-
    1. In General Tab --> Refresh WB on Open (enable)
    2. In Variables Tab --> Process Variables on Refresh (disable)
    Thanks & Best Regards, @{

  • Variable screen issue in BEX !!

    Hi Gurus,
    Problem Description - When any query is opened through u2018Web BEx Analyzeru2019->u2019New Analysisu2019 button in portal , variable screen is shown and report is getting executed. Again, if we open same query from u2018Web BEx Analyzeru2019->u2019New Analysisu2019 (Donu2019t close the session use same session), Variable screen will NOT be shown at Second time. Directly, Query will be executed with previous Variable values & result will be shown.
    I have modified following parameters but it did not take any effect to the variable screen problem.
    VARIABLE_SCREEN, MELT_VARIABLES, VARIABLES_CLEAR, USE_PERSONALIZATION
    100% points are assigned
    kindly do the needy
    Sherwin
    Edited by: sherwin paul on Jun 24, 2008 1:13 PM

    Paul,
    I have experienced similar issues with the behaviour of variable selection screens e.g. variable screen appears in the Bex Excel version but not the web version. One of our consultants has suggested that the behaviour depends on whether the variables are optional or mandatory, something I've yet to confirm.
    Regards,
    PP

  • Variable Screen Does Not Display in Bex Web Analyzer after first time

    We recently upgraded from BW 3.1 to BW 7.0 (without upgrading specifically to 3.5).  We are having a problem with our Web Bex Analyzer not showing the variable screen although the variable screen is displayed successfully when running the same query from the Bex Analyzer.  Based on feedback from other posts regarding similar topics, we modified the 0analysis_pattern template to ensure that Display Variable Screen was checked on.  We are finding that when we open the Web Bex Analyzer and do a New Analysis, the first query we try to run will always have the variable screen displayed successfully.  Any susbsequent queries we try to run by clicking on New Analysis in that same open window will not show the variable screen and will start executing open ended.  This is occurring regardless of whether the query has mandatory or optional variables and we have confirmed that there is no personalization set for the variables being used.  We have tried it with several different queries and the results are consistent.  The first query you run shows the variable screen successfully and any queries run after that do not.  Any help in resolving this would be greatly appreciated as we have exhausted our resources researching and troubleshooting this problem.

    We did open an OSS note and heard back from SAP.  We made the recommended setting, see their response below, but as they stated, it will only show variable screens for queries that have at least one mandatory variable entry after the first query is opened. 
    Response from SAP: 
    Please check if the following setting is made within your template --
    In the 'Standard Actions' of the Web Template, do you have the setting
    'Action Before First Display' set to OPEN_VARIABLE_DIALOG
    The behaviour of the variable screen is different if you use mandatory
    variables and optional variables. If you have only optional variables,
    the Display Variable does not force the variable screen.
    Also, using the parameter VARIABLE_SCREEN=X only influences the
    web application at STARTUP. This would not come into affect when you
    use the 'New Analysis' button. This button resets the dataprovider so
    this would not affect the variable screen and would not redisplay the
    variable screen as you require.

  • BEx Analyzer 7.1 Issue after upgrade to MS Office 2007

    Hi
    We upgraded MS Office 2003 to 2007 and installed SAP GUI 7.10 (Patch 9). The OS is Windows XP (SP3).
    We have also applied "BI AddOn Patch for GUI 7.10"
    When we run BEx Analyser from Windows start menu or RRMX , we notice the error message: "A critical program error occurred. The program has to close. Please refer to the trace for further information".
    Following is the trace details:
    Trace Started as: 10/3/2008 11:25:26 AM*
    ListSeparator: ,
    ExcelVersion: 12.0
    AddinVersion: 7100.2.700.1344
    BExCompression.SupportsCompression: Compression NOT supported
    Could not load file or assembly 'vjslib, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a' or one of its dependencies. The system cannot find the file specified.
    BExCheckFrontend.CheckFrontend: No Check performed (20081002) 0.156257
    10/3/2008 11:28:36 AM----
    System.Exception: CriticalProgramError ---> System.Exception: CriticalProgramError ---> System.Exception: CriticalProgramError ---> System.Exception: CriticlaProgramError ---> System.Exception: CriticlaProgramError ---> System.Exception: CriticalProgramError ---> System.ArgumentException: The item with the specified name wasn't found.
       at Microsoft.VisualBasic.CompilerServices.LateBinding.LateGet(Object o, Type objType, String name, Object[] args, String[] paramnames, Boolean[] CopyBack)
       at Microsoft.VisualBasic.CompilerServices.NewLateBinding.LateGet(Object Instance, Type Type, String MemberName, Object[] Arguments, String[] ArgumentNames, Type[] TypeArguments, Boolean[] CopyBack)
       at com.sap.bi.et.analyzer.addin.BExChart.get_Chart(ChartDescription iChart, BExExcelItem iItem)
       at com.sap.bi.et.analyzer.addin.BExItemGrid.UpdateCharts()
       --- End of inner exception stack trace ---
       at com.sap.bi.et.analyzer.addin.BExItemGrid.UpdateCharts()
       at com.sap.bi.et.analyzer.addin.BExItemGrid.OnRender(Boolean iForceRendering)
       at com.sap.bi.et.analyzer.api.BExItem.Render()
       --- End of inner exception stack trace ---
       at com.sap.bi.et.analyzer.api.BExItem.Render()
       at com.sap.bi.et.analyzer.api.BExApplication.Render()
       --- End of inner exception stack trace ---
       at com.sap.bi.et.analyzer.api.BExApplication.Render()
       at com.sap.bi.et.analyzer.addin.BExExcelApplication.OpenQueryThreaded(BExParameter iParameter)
       --- End of inner exception stack trace ---
       at com.sap.bi.et.analyzer.addin.BExExcelApplication.OpenQueryThreaded(BExParameter iParameter)
       at com.sap.bi.et.analyzer.addin.BExThreads.ProcessParameterSubExecuter.Execute()
       at com.sap.bi.et.analyzer.addin.BExExcelApplication.OpenQuery(OSObjectInformation iObjectDescription, String iRRIVariableName, String iRRIVariableValue)
       at com.sap.bi.et.analyzer.addin.BExThreads.ProcessOpenQueryExecuter.Execute()
       --- End of inner exception stack trace ---
       at com.sap.bi.et.analyzer.addin.BExThreads.ProcessOpenQueryExecuter.Execute()
       at com.sap.bi.et.analyzer.addin.BExMenu.ProcessOpenQuery()
       at com.sap.bi.et.analyzer.addin.BExUserInteraction.Process(String iStepName)
       --- End of inner exception stack trace ---
       at com.sap.bi.et.analyzer.addin.BExUserInteraction.Process(String iStepName)
       at com.sap.bi.et.analyzer.addin.BExUserInteraction.ProcessUserInteraction(Sub iSubDelegate, BExStepType iStepType)
       at com.sap.bi.et.analyzer.addin.BExMenu.Process(CMD iCMD)
       at com.sap.bi.et.analyzer.addin.BExMenu.ProcessCMD(CMD iCMD)
       at com.sap.bi.et.analyzer.addin.BExConnect.ExcelCommunication.ProcessBExMenuCommand(String iCMD)
    CriticalProgramError
       at com.sap.bi.et.analyzer.addin.BExUserInteraction.Process(String iStepName)
       at com.sap.bi.et.analyzer.addin.BExUserInteraction.ProcessUserInteraction(Sub iSubDelegate, BExStepType iStepType)
       at com.sap.bi.et.analyzer.addin.BExMenu.Process(CMD iCMD)
       at com.sap.bi.et.analyzer.addin.BExMenu.ProcessCMD(CMD iCMD)
       at com.sap.bi.et.analyzer.addin.BExConnect.ExcelCommunication.ProcessBExMenuCommand(String iCMD)
    Regards
    Madhu

    Hi
    This problem is solved.. We need to change the global settings in BEx Analyzer.. Following are the steps:
    -     After executing RRMX, BEx Analyzer screen opens
    -     Open Global Settings
    -     Select u201CDefault Workbooku201D tab
    -     Click u201CUse SAP Standardu201D
    -     And then execute the query
    Regards
    Madhu

  • Message when opening BEx Analyzer after an upgrade to 3.5

    When I open BEx Analyzer after an upgrade to 3.5, I get a message:
    Internal Error when generating the history.  Use a different view
    Is this because it is the first time I am logging onto BEx after the upgrade or is this an issue? Thanks

    Niten,
    As A.H.P suggested what version of BW did you upgrade from ? and what version of SAPGUI are you using - try and reinstall SAPGUI or install SAPGUI6.40 final.
    Also please give your front end support pack levels. This could also be due to a front end SP issue.
    Some other things that could help would be :
    Were there any problems / issues when upgrading ?
    Arun
    !!!!  Oops looks like I posted at the same time as you!!!!
    Message was edited by: Arun Varadarajan

  • NW 2004s Bex Analyzer Variable screen Vs 3.X Bex Analyzer

    Hi,
    In 3.X, if you select refresh for a workbook having multiple queries, then the function refreshes all queries and the system displays the variable screen for each query in the workbook.
    In NW 2004s, if i have the same workbook and refreshing the workbook will display only one variable screen having all the variables all the queries are using.
    This is good. <b>Except</b> <i>for refreshing workbook which is already having different "material number" in different queries.</i>
    In this scenario how do we refresh the workbook and keep the material number different for the queries the workbook is using. The variable screen in NW 2004s will show only one variable "material number" and assigning a material number will change the workbook
    <i>(Implies both the queries will be using same material number after refresh-hence unable to keep the workbook same)</i>
    We are on <b>SPS 8/FEP 801.</b>
    We applied the note <b>953402</b> (variables are displayed when you  refresh all queries)
    After applying the note we added ANALYZER-VARIABLE_REFRESH_3X=X in the RSADMIN table.
    Still in NW 2004s, only one VARIABLE SCREEN is displayed will all the variables the query is using.
    Please let me know if any information is available.
    Thankyou,
    -Sini

    Hi,
    We applied to OSS NOTE # 953402 inorder to prompt the varaible like 3.X. This note did not do anything. Please advice if any other note is available or not.
    Having a common or (one) variable screen is difficult to maintain. I had lot of problem trying to keep a workbook same as in 3.X. Diificult to perform workbook conversion.
    Example:
    I am performing workbook conversion. This workbook which I am trying to convert has multi queries.
    In one query it shows material number starting with say for eg: BA, CB and no restriction is given for cal year/month and this query has plan version as mandatory variable. (NOTE: no hierarchy)
    Other query has hierarchy for material number and the hierarchy shows material starting with BA01* and cal/year restricted to 01/2006 and 02/2006.
    When I convert the workbook from 3.X to 2004s
    1.) hierarchy drilldown icon disappears when I open the workbook in NW 2004s Analyzer
    2.) Inorder to get the drilldown icon back I clicked on "refresh" which doesn't not work consistenly.
    So I always click on "variable" icon and entered the values for the mandatory variable (plan version) and assigned hierarchy (XYZ).
    3.) After executing it, both of my query shows hierarchy.
    4.) I turned off hierarchy in one of query, set filter value for material number to  BA, CB.....( NOTE: Inorder to turn off the hierarchy I have to first deactivate it and then refresh it to make it work.
    NOTE: later I was unable to turn it ON.
    5.) The other query has hierarchy orginally(before conversion) it has 3 level drilldown and after converting it just has only one level drilldown. ( I was not able to get the original one back. I was able to filter it my material number say BA01* and cal year.
    RESULT: Unable to make the workbook indentical to 3.X. Conversion was not that succesfull.
    NOTE:
    1. The hierarchy activation/deactivation does not work properly.
    2. For eg: Select filter value for material number, the text/key shows the expected value. But If I search for those values I do not get the result. The search on material with hierarchy does not seems to work properly.
    Please let me know if you need any further details and also let me know if there any OSS Note available.
    Thankyou,
    -Sini

  • NW 2004s Bex Analyzer Variable screen problem

    Our BW system was upgraded from 3.1 to NW 2004s (SPS 8/FEP 9).
    When we refresh the query in the workbook that has multiple queries, then the variable screen displays the variables from all queries.
    For example: Query 1 has Posting Period single value variable, Query 2 - Posting Periods interval variable. When Query 1 is refreshed, the Variable input screen will display both variables - Posting Period single value variable and Posting Periods interval variable.
    Please let me know if you need any further details and if there are any OSS notes available.
    Thank you,
    Elena.

    Hello Prakash
    In BW 3.5 we had, if we have a Workbook with more than one Query, while refresh, if our cursor used to be outside the Query area, then it used to ask "Do you want to refresh all Queries on Workbook", if we say, it used to refresh all the Queries,  by Promting Variable Screen multiple times.
    "Melt" kind of function in this case should help.
    But do we have method to refresh one query of the sheet only and not rest of them. I am afraid you may say no. But thought to recheck at least once more.
    Pankaj Gupta

  • Bex analyzer variable screen input ready?

    Hi Experts,
    If we open a query in the Bex analyzer (BI 7.0 – netweaver 2004s), it seems only possible for us to enter variables in the dialog screen after the pushbuttons Ctrl + K for each variable.  Is it possible to change the default setting in the BEx analyser variable screen, so that the variables are ready for input (without the ctrl + k)?
    In the SAPhelp information, only the following information is provided.
    Prerequisites
    In the BEx Analyzer, you have executed a query that contains variables and you want to change or personalize one or all of the variables in the query.
    Procedure
    1.      In the analysis toolbar, choose Change Variable Values or in the menu, choose BEx Analyzer ® Change Variable Values.
    The Select Values for Variables dialog box appears. Follow the instructions to select a value to assign to the variable.
    2.      Specify a variant name and values for the variables for which you want to change the current values.
    Switch to display mode or use the pushbuttons Ctrl + K to enter values.
    Kind regards
    Dennis
    Message was edited by:
            D.C.M. van den Oord

    Hello All,
    We have a similar issue only in 2004s query designer when we execute a query via the web. We have the variable set up to accept multiple single values and we can pick multiple single values and add them, however, we cannot paste a list of, for example, personnel numbers from an excel spreadsheet into the web selection box to add multiple single values at one time.  Does this functionality exist?
    Regards,
    Ann Bohn

  • BEx Analyzer Query Selection Variable Screen Issue

    We are in the process of applying support packs to our system--BI7.01 and we are going from SP04 to SP10.  After the application of support packs, when we execute a query (or a workbook with attached query), the query variable screen that normally appears does not, the query just executes without being able to filter/enter selection criteria.
    We are using BEx Analyzer 3.5--long story about not upgrading to BEx 7.x.  In our systems without support packs, the queries/workbook execute as expected.  I've tried making a variable mandatory in one of the queries as a test and the selection screen then appears; however, we have hundreds of queries.
    I've searched SDN and OSS and have found some similar issues, but not a solution.  Any help is greatly appreciated.  Thanks.
    Norris

    Hello Michael,
    Thanks for the informationit's funny as I think I was stumbling upon this notegoing support pack by support pack--when you posted it. 
    We applied to our development system and we are now getting the selection screens, so it does appear to resolve the situation.  Thanks again for the information.
    Norris

Maybe you are looking for

  • Can i have the same Apple-Id-Account to two iPhone?

    Can i have the same Apple Id Account to two iPhone? Or do I need to get a new one? With iPod you can have more than one to the same ID? Regards , Yvonne

  • Cannot Get Sound Added to PDF from InDesign Export

    I am trying to export and InDesign document for the purpose of creating an interactive PDF. Here are the steps I am taking: 1.     create indesign cs6 file; 2.     export it as a swf file; 3.     import swf file in new indesign cs6 document; 4.     e

  • Can't reinstall InDesign CS3

    I was a longtime PageMaker user, and upgraded from PageMaker 6.5 to InDesign CS3 a few years ago. I'm not a designer, so use it mostly for family projects.  Last month my computer died and I took it to a computer shop, where they had to wipe it clean

  • No server was available to process the request

    Greetings, BO that I have is XI R2 with service pack 5. The report is Desktop Intelligence. I can change the values of the prompts in Desktop Intelligence but when I try modify the values of the prompts of some reports in schedule of Infoview, I rece

  • Roadtrip question/problem

    I bought one of the FM transmitters and it is the Road Trip one and it worked with my ipod nano then all of a sudden it stopped working for just my ipod not any one elses. What could the problem be?