Bex Analyzer - Filling cells

Dear all,
simple question:
İn bex analyzer report shows as follows:
A   -B - C-  120 usd -- 4 pc
   -    -       D -120 usd- -4 pc
when its same char, it does not paste A again in the second line as it repeats.
Is there any chance we can tweak that in bex analyzer and excel fills every cell?
Thanks
Edited by: john mcquade on Jan 25, 2010 1:39 PM
Edited by: john mcquade on Jan 25, 2010 1:40 PM

Hi John,
In the BEx Query Designer open the overall settings for the query and uncheck "Hide Repeated Key Values" in the display tab.
BR
Stefan

Similar Messages

  • Front-end memory and limitation cells of the BEX Analyzer

    Hi BI experts,
    After BW upgrade from BI 7.3 to BI 7.4 some heavy workbooks stopping to work, the error is "Client Out of Memory", the cause of this error is the memory capacity of .NET framework, this process can allocate a maximum of approximately 1.2 gigabytes (GB).
    The notes 1040454 and 1411545 says that it´s possible to execute something like 750,000 cells but we made some adjusts and we could increase it until 1,800,000 cells, below some configuration we´ve made:
    Query Designer:
    Result Rows Always
    Supress;
    Display as Text or key;
    Supress Zeros as Active (All Values = 0) and Effect on rows and columns.
    Bex Analyzer:
    Display Sort Icons Disable;
    Apply formating Disable;
    Allow navegation Disable;
    We need some orientation how to further increase this limitation, or leaving the query lighter or increasing the memory limitation of .net framework or backing to BEX 3.5 funcionalities.
    Has anyone encountered such problems in the update? Some alternative solution ?
    Thanks !

    Hello Caio,
    The limitation lies on .Net Framework 32 bits which can handle 1.2 gigabytes.
    You are reaching 1.8 Million because your datacells has no data or almost no data.
    There is a KBA documenting your issue: SAP Note 1860872
    There you will find a recommendation of Openhub, that allows you to extract data.
    Just remember that BEx Analyzer is a tool for query navigation, not mass data extraction.
    Kind Regards,
    Edward John
    SAP AGS

  • Cell definition in Query Design within Bex Analyzer

    Hello,
    I would like to use special cell definition to visualizing the difference row definition between 2 columns (last year and actual year). With "Cell Definition" function in Query Design within Bex Analyzer there's a option to select a new restricted key figure for a related cell. But as a result I just can see a star (*) against a result number in that field. Do you have an idea, how can I solve this problem?
    Thanks and Regards,
    Nuran

    Hi again Dirk,
    there's not a unit problem. We use 2 different restricted key figure definition for a same row. The first restricted (or can be decribed as calculated key figure) key figure must be used in the first column to represent the value of the last year. And at the same row with usage of same text (for example: cost of goods sold)the second restricted key figure should be used to show the value of actual year (B2:costs in euro). The problem is the key figure definitions are totaly different; they're using different account groups etc. Cause of, I wanted to use cell definition function. In the first value field (B1) should be shown first key figure but I just get star (*) and a wrong value in the formula field of excel (between the toolbars and the result area).
    Thanks for your reply.
    Nuran

  • Changing scaling factor for each cell in Bex Analyzer

    Hi,
    We have a query with 2 structure (1 structure in rows, 1 in columns). We execute the query with Bex Analyzer in Excel.
    We would like to change the scaling factor for each cell. If we use the function 'Properties' for the active cell (context menu), we can change the scaling factor only for one cell.
    Is it possible to change it for the complete table?
    We use BI 7.0, patch 14.
    Thanks,
    Peter
    Edited by: Péter Egyedi on Jan 25, 2008 5:18 PM

    Have you got the solution for this problem?

  • Cell in Bex analyzer

    Hi
    can you please tell me the use of Cells in Bex analyzer.
    Will it have effect on signs (+/-).
    Regards,
    Anita

    Hi  ,
    I got th Solution.Thanks for your help.
    User is using 2 structures on different axes within your query there is the problem
    The problem is this. You have to structures for example. Structure one as the members A, B, C and structure two X, Y, Z.
    you've switched on the sign reversal for row Y and column C.
    All fields in this area are no on sign reversal.
    But! If you now swich of the sign reversal for row Y, the sign reversal
    for cell Y/C is also switched of.
    This is what happens in your query.
    If you want to have the sign reversal back in the whole row C you have
    to switch of the sign reversal for row C, save the query and switch in
    the sign reversal for row C once again (and save).
    You can refer note 332915 & 568630 for ore details.
    If you would like to activate the +/- sign reversal for the whole column
    again, you must first deactivate the +/- sign reversal for that column
    store the structure/query and then activate the +/- sign reversal again
    Thanks & regards,
    Anita

  • BEX Analyzer 7.0 - Use the content of an excel cell as an input value

    Hi all,
    Is it possible to use the content of an excel cell as an input value for a bex variavel?
    Iu2019m using bex analyzer 7.0.
    Thanks in advance,
    Cátia Coelho Silva

    Hi Catia,
    Yes it is possible to import values from exel. But this will gives you "INCORRECT INPUT PARAMATERS"..
    So it is still best to use "Notepad" as your import file type.
    Just copy your input parameters on the notepad then upload it via 'import text file'.
    Please be sure to use Multiple selection type variable.

  • Create a VC Model for BEx queries with Cell Editor

    Hello All,
    I am trying to create a VC Model for BEx queries with Cell Editor.
    BW Development Team has created a BEX query with complex restrictions and calculations using Cell Editor feature of BI-BEX.
    The query output in BEx analyzer is correct where all values are being calculated at each Cell level and being displayed.
    But, while creating VC model, system is not displaying the Cells.Thus, no VC Model can be created.
    I have executed below steps:
    1. Created a VC Model for BEx Query - ZQRY_XYZ
    2. Create Iview -> Create a dataService -> Provide a Table from the Output
    In the Column field system is not showing any of the Cells (present in Cell Editor)
    Please help me to solve this issue.
    Thanks,
    Siva

    Hi
    If 'Cell Editor' is been used then that query must have the structure in it. You have to select that 'structure' object in your 'VC Table'.
    If you select that then you will get the required result in the output. This structure will be the structure where 'cell reference' is used in BI query, You have to select that structures name.
    Regards
    Sandeep

  • Error in Bex Analyzer including the filter button command in Callback macro

    Hello,
    I have the following problem with the function filter button in the Bex Analyzer included in the callback macro:
    Because of using 2 hierarchies in the filter the setting drill down to level 2 in the query gives no right output in the Bex Analyzer. The drill down level 2 is not shown. SAP recommends the include of a filter button to solve this problem. With a filter button in the sheet the problem was solved.
    But after including the filter button command in the callback macro I get an error in MS Excel.
    The callback macro starts, the filter was set by the user and the data was refreshed. Because of the refreshing of the filter the callback function the callback function starts several times. After setting the filter the first time, the following macro avoids the several starting of the set filter function:
    Sub CallBack(ParamArray varname())
    On Error GoTo err_handler
       Dim lRange As Range
       Set lRange = varname(1)
    'Filter entfernend/delete filter
    Dim ZeichenFilter As Long
    ZeichenFilter = Len(Sheet4.Cells(41, 3).Value)
    Dim Filter1 As String, Filter2 As String
    Filter1 = Left(Sheet4.Cells(28, 3), ZeichenFilter)
    Filter2 = Left(Sheet4.Cells(41, 3).Value, ZeichenFilter)
    If Filter1 <> Filter2 And Filter2 <> "" Then
        onAction = True
        onAction = False
    End If
    'Filter setzen mit einmaligem durchlaufen/set filter and run one time
    If onAction = False Then
        onAction = True
        Call Sheet4.BUTTON_55_Click
        onAction = False
    End If
    exit_handler:
        Exit Sub
    err_handler:
        MsgBox Err.Description, vbOKOnly, "Error in " & " setMusterSub"
        Resume exit_handler
    End Sub
    After the filter was set the callback macro starts the second time. Then the Bex Analyzer erros with the sandglass. The working on VBA is possible, but not the working with Bex Analyer . Values in Excel weren’t shown.
    How can I avoid this error?

    Once I am adding VAR_VALUE_1 to the static parameters, the system generates two messages error:
    Program error in class SAPMSSY1 method : UNCAUGHT_EXCEPTION
    System error in program SAPLRRS2 and form GET_SID-1
    Best Regards,
    Hanit

  • Problem of hierarchy in bex analyzer

    Dear all,
    I met a problem when I using Bex analyzer to run a query, there is a characteristic 0CS_PLEVEL (posting level) with a hierarchy. If the characteristic is displayed in the row or column, i can filter with the hierarchy node, everything seems to be fine. But if the 0CS_PLEVEL is set to be a free characteristic in the query, when I filter with hierarchy text node (not leaves), then there will be wrong message about 'No applicable data found', but if I add drill down according to Posting Level in rows, it indeed has data value.
    And I tried filtering value with same hierarchy node with other query which is built based on Multiprovider, everything is fine.
    I wonder if there is any speciall setting for filtering by hierarchy node in the query based on virtualprovider 0BCS_VC11?
    Your reply will be appreciated.

    Hi,
    In the Exception definition,Make sure you have selected following :
    In Display tab    ->    Select Exception affects data cells
    in cell restrictions tab  -> Exception affects everything
    After that,once you execute the query,Exceptions should be shown on all levels.

  • IP - Issues with Input Query: Works on Bex analyzer but not on Web

    I am doing the following:
    Created a Aggregation level for a multi provider which has only real time infoproviders associated with it
    Created the query using Bex Query Designer availing all the options for planning
    When I execute this query it executes using a web template and does not open up the Key Figure cells for input, I had tried using the Web Application designer with Save button but still the same issue
    I tried the same on Bex analyzer and it works fine
    Please help to resolve the above issue.
    Thanks in advance.

    Hi Ram,
    Cells should be input enabled on the web just running the query. No need to create a Webtemplate, altough you need to have the webtemplate to be able to use the "save data" function.
    Maybe your query is not input ready at all, and you're misinterpreting analyzer layout.
    To test this, please enter some plan data in analyzer, right click and choose "save".
    Please check if data is written to the real time infoprovider.
    Hope this helps you.
    Regards,
    Miguel P.

  • Macro not working in BEx Analyzer

    Can you please explain why my Macro is not working?
    We're on BI 7 with Excel 2007. I have done the following:
    1) Open Workbook from BEx Analyzer and the result display on the worksheet. The was inserted in C10 and therefore, the result was display from C10 onwards.
    2) I have created a Macro with the following code:
    Sub Macro1()
    ' Macro1 Macro
        Range("C5").Select
        With Selection.Interior
            .Pattern = xlSolid
            .PatternColorIndex = xlAutomatic
            .Color = 65535
            .TintAndShade = 0
            .PatternTintAndShade = 0
        End With
    End Sub
    3) When click to run the Macro manually, I can see the color of C5 is changed.
    4) Now I have include this Marcro in Workbook Setting ->Exits tab, Run Macro on Refresh. Here I enter my Marco name.
    5) In Workbook Setting ->General tab, I also set the Refresh Workbook on Open option.
    6) I have also set the Trust Center setting: select Trust access to the VBA project and Enable all macros.
    7) Then I save the Workbook.
    8) when I re-open the Workbook, the color of C5 is not change!!!
    Can you please help.

    Aglukas,
    Thanks again. I understand the name of the Macro can be anything and this is how to create the Macro:
    1) Run workbook, the query result display on the screen.
    2) In Excel 2007, I click on Developer tab ->Macro.
    3) Enter Macro name (Macro1) and click on Create button.
    4) I have VB editor open with following:
    Sub Macro1()
    End Sub
    5) So added the following code to Macro routine in VBA Module:
    Sub Macro1()
    With ThisWorkbook.Sheets("Sheet1")
    Stop
    .Activate
    .Cells(15, 1).Interior.Color = RGB(220, 254, 250)
    End With
    End Sub
    6) I then added the Macro1 to Workbook Setting ->Exit tab, and click on Add Macro button.
    When I run/refresh the workbook, I didn't get into debug mode at all!!!
    What is wrong in above steps?
    Please advice, thanks.

  • BEx Analyzer (7.x): currency change when new formula created

    Hi All,
    I have a strange one.  Query is executed in BEx analyzer.  A new formula is created outside the query results window using excel functionality, and the currency changes from USD to DM. 
    Example query results: 
    Cell A1: Var 1 = $150.00
    Cell B1: Var 2 = $160.00
    Cell C1: Var 3 = $70.00
    New formula created using excel functionality:  =sum(A1+B1) displays as 310.00 DM
    The language settings have been checked for the operating system and for SAP (user data) and they appear to be correct.  Is there another setting to be checked?
    Thanks,
    Pam

    sap said it was working as designed.  suggested we look at regional settings on laptop and make a workbook template with us settings.

  • BEx Analyzer - Convert to formula - Dynamics of a hierarchy

    Hi BI-Experts,
    I have a question regarding the BEx Analyzer built in functionality "convert to formula".
    Once I have done this, the report is more ore less static, establishing a fixed link between the cell and the query result.
    (BExGetData(u201CDATA_PROVIDER_1u201D,F8,E10)
    Let's say I had included a G/L account hierarchy and converted the analysis grid item to formulas: I will lose drill down functionality of the hierarchy, drag & drop etc.. I can live with that.
    But what happens, if I update the G/L hierarchy in BI by uploading from ECC and someone added an additional text node and 3 new G/L accounts. They won't appear in my "convert to formula" report, even when refreshing, right?
    Does anyone know a work-around for a highly formatted report in BEx Analyzer which keeps the layout when refreshed (only way I know is with "convert to formula") AND using hierarchies which should be able being updated?
    Every hint is much appreciated!
    Kind Regards,
    Steffen Lange

    >
    Steffen Lange wrote:
    >
    > But what happens, if I update the G/L hierarchy in BI by uploading from ECC and someone added an additional text node and 3 new G/L accounts. They won't appear in my "convert to formula" report, even when refreshing, right?
    >
    > Kind Regards,
    > Steffen Lange
    Thats right, as now the key figure values are basic excel formulas though they refer your dataprovider.
    The only option is to update the value of the hierarchy (new nodes etc) in the workbook too, you can add a new row and insert the new hierarchy value it should pick it up and key figures populated accordingly (you may need to put right row column value for your key figure calculation formula).
    Edited by: Praveen G on Aug 12, 2009 3:54 PM

  • BEx Analyzer: User ID based performance issue

    Hello Ladies and Gents,
    <b>The issue:</b>
    My BW team just upgraded our system to 2004s and we are experiencing an odd userid based performance issue.  If we run a query from the BEx Analyzer with user ID 'A' it takes about 3min for the variable selection screen to appear. If I log into the same machine user ID 'A' was using on my user ID B the query variable selection screen appears within seconds. What could possibly cause this?
    <b>What we know so far:</b>
    1. Investigated the security roles, seems like that is not the issue.
    2. It is PC client independent.  Two different user IDs(A and B) on the same machine running the same query in the same way (clicking through the BEx browser) produces different response times for the appearance of the variable selection screen. 
    Points will be rewarded and help will be greatly appreciated!

    User specific personalization is retrieved before displaying the input variables. That might be a possibility, but hard to see it making such a difference.  Do you always try the sequence of User A, then User B, or have you confirmed that when you start with User B, it is quick, and tehn slow whne trying User A?
    Probably the best approach is to activate Trace and then logon with User A, turn trace off and print or save, then do the same thing for User B and compare.  The trace will show you all the various SQL stmts and such that run as part of your trying to launch the query.
    Please post back anything you learn.
    Some info on Personalization  for the Help pages.
    Personalization in BEx
    Use
    This function allows users to fill variables with user-specific values, to save user-specific accesses to BI objects for the history view in the BEx Open dialog box, and to save user-specific start views for Web applications.
    Integration
    The personalized data is stored in different DataStore objects, according to the personalization area.
    ·        User-specific variable values are stored in the DataStore object 0Pers_VAR.
    ·        Personalized data for the history view is stored in the DataStore object 0Pers_BOD.
    ·        Personalized start views for the Web application are stored in the DataStore object 0Pers_WTE.

  • Bex Analyzer 7.0 - BexEventHandler in Netweaver 2004s

    Hi, I noticed that in Bex Analyzer 7.0, there is a new class called BexEventHandler which gets hit each time I select a cell or a worksheet within my VBA code.  This did not happen in Analyzer 3.5.  And because of this, I am experiencing major performance issue in my macro.
    I have a workbook that contains 10 queries (10 worksheets) and a VBA code that merges all the data from the queries into 1 single worksheet.  Upon conversion to 7.0, my code is now running extremely slow as it is always going to the BExEventHandler class at each cell.select or sheet.select.
    Does anyone know how to bypass this BexEventhandler in Bex Analyser 7.0??
    Would appreciate any feedback you can provide.
    Thanks,
    Sheila

    Hi, I found the command in VBA that does disables the Bex event handler code.
    Application.EnableEvents = False
    Set this to false before your code starts and set it to true again after your code.

Maybe you are looking for

  • Drag n Drop question

    hi. this is what i want to do: drag a file from a windows desktop, drop it into an applet that exists in a browser. the applet reads the local path and filename of the dropped object, and uses that to retrieve the file from the local system and uploa

  • Pro Applications Update 2009-01 doesn't change version numbers?

    Hi, I ran the Pro Applications Update 2009-01 on my FCS installation. The update seemed to work fine, but when I open up FCP or any of the other apps, the version numbers are not changed. From the Pro Application Update page: "Pro Applications Update

  • Menuitem enable Flex 2

    I am positive this has to be simple. How can you programmatically disable/enable a menuitem in Flex 2. I have been beating my head against the wall for two hours now. Any help would be appreciated. Thanks so much for any help! CurtKauf

  • After hiding photoshop and returning, all collapsed document windows uncollapse

    Hi, I'm on Photoshop CS6 with my documents in the 'float all in wondows' view. I have say 20 documents open, 19 collapsed into the dock with the one document left i'm working on. I hide photoshop to go to the desktop, click back into photoshop when d

  • N8 screen will not turn on ...New phone just bough...

    N8 screen will not turn on ...New phone just bought today and screen will not come on