BEx Web Application Designer trouble, fonts doesn't change

Hello all
I have some trouble with BEx and his fonts. i create a graph using BEx, and i want to change the fonts and the size of the text. Everything is ok up to this, the display show the good result , but after, i want to publish the page on our portal with the graph inside it. But when we do that, all the font of the graph change back to a standard police (look like arial)
I ve search a little bit in all the note, and i ve found 596825 and 1028690. I ve follow the instruction, and i have check the igs, set up patch 19, and check the log. All the font that i ve set are loaded when i restart the igs, but still when i display the pages, the display is still in standard format. I m not sure i ve changed my gfwchart file like i have to do , can someone check it (( i m trying to set Courrier New for test : http://img519.imageshack.us/img519/360/print4vr9.jpg )
Can someone help me?
Regards
Chris

I ve notice something that could be interresting
I ve normally set up igs 6.40, with patch 20. but when i look in the status area
REGISTERED_INTERPRETER
Server Port Type Version Author
PRYEDBW 41001 BWGIS 6400.0.15.10 SAPPH10
PRYEDBW 41001 CHART 6400.0.15.1007 SAPGFW
PRYEDBW 41001 IMGCONV 6400.0.15.0 SAPPH10
PRYEDBW 41001 XMLCHART 6400.0.15.1003 SAPKG10
PRYEDBW 41001 ZIPPER 6400.0.15.2 SAPPH10
PRYEDBW 41002 BWGIS 6400.0.15.10 SAPPH10
PRYEDBW 41002 CHART 6400.0.15.1007 SAPGFW
PRYEDBW 41002 IMGCONV 6400.0.15.0 SAPPH10
PRYEDBW 41002 XMLCHART 6400.0.15.1003 SAPKG10
PRYEDBW 41002 ZIPPER 6400.0.15.2
but i have restart the igs after each upgrade. Must i erase de rfc link and recreate them? or is there any way to upgrade this informations?

Similar Messages

  • Calling a webservice from within Bex Web Application Designer

    Hi
    I have a web-template built with BEx web application designer which also contains textboxes. This text should be stored by calling a webservice (standard BI-documents are not an option).
    Can anyone tell me how I could call a webservice from within the BEx web template to store the text contained in the textbox? The webservice-call should include some of the filter-varialbes of the web application.
    Is this only possible by the use of a JavaScript WebItem? If so - does anyone have an example of such a JavaScript.
    Thanks a lot in advance.
    Kind regards.
    Christoph

    Thanks for your response. The BSP page would work out fine if I only needed to save the data.
    But the next time I call the webtemplate, the textarea should be filled by another webservice call with the stored text (so the text can be modified und saved again). This will not be possible by calling a BSP page.
    Do yoiu have any suggestions how to integrate the text (return value from the webservice call) into the textbox in the webtemplate?
    Kind regards.
    Christoph

  • Print PDF file with the lay out created in the BEx web application designer

    Got the following questions (problems) when print a web report created in BEx Web Application Designer to a PDF file:
    1. The tile (which has a company logo and report name in it) was not printed, is it possible to print a title (with company logo) on each page of the PDF file?
    2. Want print the filters that have value specified on the PDF file, is it possible to do this?
    Any help is appreciated, thanks.

    Hi Simon,
    you can achieve this requirement i.e. using this way of implementation:
    1. Create a new template which contains the required fields (company logo etc) and set the visibility of the top container to "hidden". Add a empty data provider to this template and add the filter values (variable names) you want to display on the PDF. However be aware that the name for the (empty) data provider must match the name of the data provider within the original template you want to print.
    2. Open your original template and include the template you created in step 1 (Advanced: Web Templates). Choose the appropriate location (above/below the analysis item.
    3. Check the settings of your export command: do not set a special web item to be printed.
    If you export the template within web the second template should be printed correctly.
    Brgds,
    Marcel

  • Bex Web Application Designer issue: portal communication error

    hi experts,
    I am working with Bex Web Application Designer in BI7. we are using SP9. When i try to use the Web template its giving below error.
    The Requested operation could not be performed due to portal communication error.
    its message class is RSBOPLAP and message number is 018 and description is Java System error: An unknown error occured During portal communication.
    when i double click the below error details given.
    Diagnosis
    An error occurred in the BI components on the SAP J2EE Engine.
    System Response
    Procedure
    Contact your system administrator to have the error analyzed in detail.
    Procedure for System Administration
    Start the Visual Administrator, log on to the SAP J2EE Engine and choose "<J2EE_SID>" ->"Server" -> "Services" -> "Log Viewer".
    The file "defaultTrace.trc" includes detailed information about the error that occurred. In Windows, you can find this file in the Log Viewer under "Cluster <computer name>" -> "Server <server number>" -> "<drive>:\usr\sap\<SID>\JC<INSTANCE>\j2ee\cluster\server<NUMBER>\log". ". In Unix, the file is located under "/usr/sap/<SID>/JC<INSTANCE>/j2ee/cluster/server<NUMBER>/log".
    If the file does not include enough detail about the error, you can increase the log level to obtain more information. To do this, choose "<J2EE_SID>" -> "Server" -> "Services" -> "Log Configurator". On the "Locations" tab page, choose "com" -> "sap" -> "ip" -> "bi" -> "webapplications". Using the selection list on the right side of the screen, you can increase the log level, whereby "DEBUG" represents the log level with the most information. You can save your settings by choosing the "Save" icon. The change to the log level is active immediately. Once you have successfully analyzed the error, you should set the log level back to its default value using the appropriate pushbutton; continuous writing to the log file negatively affects the overall performance of the system.
    please give solutions to resolve the issue.
    regards
    vadlamudi

    hi shambhu,
    thanks for the reply, yes its related to basis but they are unable to trace it out. is SP9 support Bex Report Designer and Bex WAD??
    regards
    vadlamudi

  • RSBOLAP 018  Java system error in BEx Web Application Designer

    Hello,
    while doing inside BEX Web Application Designer "validation of webtemplate" with
    command "validate on server"  I get following error message of WAD  :
    " Message RSBOLAP 018   description : Java system error : an Unknow Error occured during portal communication"
    My procedure till now was ( please see results as screenshots in attachment) :
    a) ckecking prerequisites for "Java template installer'" --> result "prerequisites.jng"
    b) running "Java template installer" ->  " result templateInstaller.jpg"
    c) running Bex Web Application Designer as mentioned above results in error
       message as mentioned above
    d) running Diagnostic & Support Desktop Tool  --> "result Diagnostic support desktop tool.jpg"
    It says that something is wrong with "BI Mastersystem" because of failed connect to
    message server.
    Please advice me what I should do.
    Thanks in advance
    Regards,
    Oscar

    Hello
    It is obvious that the connection between the ABAP and the Java is not working.
    There should be a JCo RFC from the portal side to the ABAP stack set up and an RFC from the ABAP stack to the portal.
    Check the entries of the table RSPOR_T_PORTAL
    The RFC specified here should be the one mentioned above (ABAP - Java)
    Check the name of the system should be SAP_BW
    Is the parameter icm/host_name_full set on the ABAP stack with the domain name ?
    Connect to the BI portal:
    http://FQDN:5NN00/irj/portal
    Navigate to system administration -> system configuration -> system landscape -> expand "portal content" -> systemlandscape -> SAP_BW
    Right click on SAP_BW - Open - Object
    Here you need to maintain these:
    ITS Description - BW ABAP Logical System Name - Tx SCC4 or BD54
    ITS Host Name  - FQDN_OF_BW_ABAP:port - You can use the value of icm/host_name_full parameter and retrieve port number from Tx SMICM - Services
    ITS Path - /sap/bc/gui/sap/its/webgui
    ITS Protocol  - Select http
    Logical System Name  - BW ABAP Logical System Name - Tx SCC4 or BD54
    Logon Method  -SAPLOGONTICKET
    Message server - BW ABAP FQDN
    SAP Client - BW ABAP Client Number
    SAP System ID (SID) - BW ABAP SID
    Server Port - 39NN
    Web AS Description - BW ABAP Logical System Name - Tx SCC4 or BD54
    Web AS Host Name - FQDN_OF_BW_ABAP:port - icm/host_name_full and retrieve port number from Tx SMICM - Services
    Web AS Path - /sap/bw/BEx
    If everything is set properly then do a test connection.
    Good Luck
    RB

  • Bex Web Application designer 3.x  windows 7

    Good Morning,
    Im trying to use Bex Web Application Designer SAP BW 3.x doenst working at windows 7.
    its ask one version above ie 5.
    Im using ie 8, i cant install the ie 7.
    there is anyway i solve this problem?
    i patched of last support package, even it not working
    thank u
    regards,
    Amit

    Dear Amit,
    unfortunately I get the same error here when I try to run the WAD 3.5 under Windows 7. I only can hope that there will be a work around, as SAP will officially support Win7 only with SAPGui 7.20 which will be released in Q1 next year. I did not get any information that BW 3.5 will still be included in Gui 7.20, but probably someone who is reading the forum from SAP can provide an answer...
    Another strange thing which I discovered in Win7 is, that when I execute a query and the variable screen is displayed, most of my variable descriptions are missing. When I toggle back and forth some windows everything appears correctly. So I guess that (hopefully) the display device driver needs only another update...
    Regards,
    Andreas

  • BEX Web application Designer displaying Java Communication Error

    Hi,
    When we are using the BEX Web application Designer to create new web template, it throws error saying "Java Communication Error: An UnKnown Error Occured During Portal Communication."
    ====================================================
    Diagnosis
    An error occurred during communication with the BI components on the SAP J2EE Engine.
    System Response
    Procedure
    Contact your system administrator to have the error analyzed in detail.
    ====================================================
    Kindly help to resolve this issue.
    Regards, Krish

    Hi,
    Please check below document for connection between BI and Portal
    https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/d082fe32-5037-2b10-3288-fd009f695c74
    You might be doing something wrong in any of these steps.
    Regards,
    Kams

  • XCelsius + BICS + Publish to EP + BEx Web Application Designer

    Dear Friends,
    Any one have idea about how we can publish an XCelsius Dashboard (with BICS connectivity) to the SAP Enterprise portal using Bex Web Application Designer?
    I tried to publish the dashboard using the iView, by following the below link.
    http://wiki.sdn.sap.com/wiki/display/BOBJ/IntegrationofanXcelsiusdashboardinNetWeaverEnterprisePortal
    Since it can only support individual report, I can not use this option in my client.
    Appreciate your help to provide me the information how we can publish the dashboard using Bex Web Application Designer.
    Thanks & Regards,
    Ajish George

    Hi,
    Did creating the iView using the instructions in the link work for one Xcelsius report?  Can you explain what you requirement is or expand on your comment "Since it can only support individual report, I can not use this option in my client.".  One iView can only launch one object.  If you have multiple BW connected XC files to launch I think that you will have to create multiple iViews with the "DASHBOARD=" each XC file value in each iViews  BEx Web iView query string parameter  setting.
    If you only want one link off of your Portal then you could create a BW 7.0 Web application where you could use objects like buttons to launch each individual URL string for the seperate dashboards.  The challenge with this would be that your URLs would be static and if you are using a regular BW landscape, DEV / QAS / PRD, then you would need to employ logic find and  update the system part of the URL.  I am not sure how this would be done, but it would probably require JavaScript.  If you do report development in your PRD system this would not be an issue.
    From a support perspective I would suggest using a container iView to group your XC reports together and then create a seperate iView for each XC report.  This eliminates dealing with the system identifier as the Portal enviroment manages this as the objects are transported through the systems.  A container iView with the action iViews in it would look like a menu structure on your Portal.
    Rgds,
    Mel

  • Bex Web Application Designer launched from desktop NOT SSO (single sign-on)

    NW 2004s
    BI 7.0
    The SSO from the Portal to BI/BW is working correctly, The SSO from BI/BW to the POrtal is working correctly.
    The problem is from the desktop, launching Bex Web Application DEsigner, it prompts to Logon to the BI system, then when you execute the selection it prompts you to log on to the Portal. I would expect the Portal logon to be SSO. Is there an SSO option for the Bex WAD I need ?
    Is there a  Bex tool or desktop configuration that I need to implement?
    Thanks in advance for any help
    Sarah

    Hello Sarah,
    Please refer this SSO SAP Pages
    http://help.sap.com/saphelp_nw04s/helpdata/en/12/9f244183bb8639e10000000a1550b0/content.htm
    For Portals
    http://help.sap.com/saphelp_nw04s/helpdata/en/89/6eb8deaf2f11d5993700508b6b8b11/content.htm
    You can also refer this forum
    /thread/342517 [original link is broken]
    Hope it helps
    Thanks
    Chandran
    Edited by: Chandran Ganesan on Feb 6, 2008 8:26 PM

  • BEx Web Application Designer with portal...

    Dear all,
    Right now we are using EP for execution of reports.. till now we have used querydesiner only...
    Now the requirement is to use  BEx Web Application Designer with portal...can anyone give me some idea abt how to connect the EP with  WAD..
    Points will be awarded
    regards
    venu

    Dear Venu,
    Please check this link:
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/b0a5216a-349c-2a10-9baf-9d4797349f6a
    Regards,
    Ramkumar.

  • I get 'SAP BEx web Application designer has stopped workin' when click WAD

    Hi,
    When I click on WAD(Web Application Designer option from Business Explorer menu),
    I get "SAP BEx web Application designer has stopped working".
    I am running VISTA.
    Any hints on how to deal with this problem?
    Thanks

    Hi,
    I uninstalled and installed again the GUI and Bex Explorer
    I installed again SetUpAll.exe and selected:
    --SAP GUI for Windows 7.10 (Compilations3)
    --BW 3.50 Add-On for SAP GUI 7.10
    --Business Explorer
    On completion, I had two options for WAD:
    --Web Application Designer (SAP BW 3.x)
    --Web Application Designer
    When I point my mouse on "Web Application Designer " for selection, there is a message that
    "Business Explorer Web Application Designer  - Can only be used in SAP NetWeaver 7.1"
    and when I go ahead to click on it, I get the error message I reported in my initial post
    If I select Web Application Designer (SAP BW 3.x), it takes me in alright but the view is a bit different, in that in the New template of the Web Application, on the right pane, I do not see the icon for DataProvider which used to be there when I used to work in "Web Application Designer" instead of  "Web Application Designer (SAP BW 3.x)"
    Any hints?
    Thanks

  • BEx Web Application Designer Execution Errors

    Hi there,
    When I execute report via BEx Web Application Designer, the error message is shown as 
         The metadata of "ITE" "CHART_ITEM" are incorrect for parameter "LEGEND_POSITION"
         The metadata of "ITE" "CHART_ITEM" are incorrect for parameter "LEGEND_POSITION"
    I can not get the review form.
    Did anyone meet this problem? How to resolve it?
    Thanks in advance
    Edited by: Jonas Sun on Oct 2, 2008 12:40 PM
    Edited by: Jonas Sun on Oct 2, 2008 12:41 PM

    Hi
    In the XHTML code for the web template check the value being assigned to LEGEND_POSITION . If its some worng value assigned then please chnage it and execute the web template.

  • BEx Web Application Designer old tool?

    Hi,
    Someone told me that BEx Web Application Designer is an old tool that's not used anymore. And that Visual Composer and Web Dynpro are better tools to use. Is this correct?
    Also, I was wondering if anyone could explain the difference between BEx Web Application Designer, Visual Composer and Web Dynpro. What situations do one use the different tools?
    Kind regards,
    Maria Perez

    Maria
    Welcome to SDN
    Bex Web Application is not an old tool and it is widley used for Web Reporting.
    Actually the purpose of these three tools are different so all of them are extensively used.
    Please see the following links for more details
    Visual Composer
    https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/45bfd990-0201-0010-e1b3-a38f22a5b5b2
    Webdynpro
    https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/7bfea990-0201-0010-44a7-84a74971b795
    Web Application Designer
    http://help.sap.com/saphelp_nw04/helpdata/en/1a/456a3badc1b315e10000000a114084/content.htm
    Hope this helps
    Thnaks
    Sat

  • Bex Web application designer

    Hi all,
    I have to customize a report that has been generated by the Bex Web application designer. The report is available on our portal under "Business Intelligence" > "Business explorer" > "Bex Portfolio".
    I need to understand the technical context. The generated report, is it a BSP? If yes, where can I find it in BW (which name)? I already know that in transaction RSRT I can retrieve the name of an ABAP program that has been generated by Bex, but I don't manage to figure out what it's used for.
    Thanks in advance,
    Jeroen

    Hi,
    Thanks for your reply.
    I want to add a contextmenu item 'do sth'. When the user rightclicks on a cell in the BW report & chooses 'do sth', an existing iView should be opened with some parameters that are dependent on where the user clicked in the report. Can all this be achieved in the WAD?
    Edit: I've been reading the WAD help and it seems to be possible using javascript. I'll open a new thread for more info on retrieving the parameter values.
    Thanks,
    Jeroen

  • BEx Web Application Designer - formatting text_item

    Hello,
    I'm a newbie at the Web Application Designer and I collected my first experience in it. Now I am having a problem with the formatting from a text_item. Afterward changing the font size and color, I saved the report but nothing changed. I ticked the attribute 'Display Text Only' from the text_item and specified the horizontal alignment of the text_item and it worked. If I change the font size and font attribute to "bold", it doesn't work.
    Have anyone a solution? Thank you for helping!
    Kind regards
    Tobias Kreuser

    Hi Stefan,
    I don't know where I write the <(remove) b> Object < (remove)/b> in the code. Because my code is displayed different as your. The name of the text-items are "text_item_1" and "text_item_2".
    Here is my code:
    <bi:GROUP_ITEM name="GROUP_ITEM_ANALYZE" designheight="600" designwidth="600" >
                                <bi:CHILD_ITEM_REF value="CONTAINER_LAYOUT_ITEM_3" />
                                <bi:PADDING value="X" />
                                <bi:GROUP_DESIGN value="SECONDARYCOLOR" />
                                <bi:WITH_CAPTION type="CHOICE" value="" />
                                <bi:CONTAINER_LAYOUT_ITEM name="CONTAINER_LAYOUT_ITEM_3"  designwidth="600" designheight="600" >
                                    <bi:ROW_LIST type="ORDEREDLIST" >
                                        <bi:ROW type="ORDEREDLIST" index="1" >
                                            <bi:COLUMN type="COMPOSITE" index="1" >
                                                <bi:CHILD_ITEM_REF value="TEXT_ITEM_1" />
                                                <bi:COLSPAN value="1" />
                                                <bi:HALIGN value="CENTER" /> 
                                            </bi:COLUMN>
                                            <bi:COLUMN type="COMPOSITE" index="2" >
                                                <bi:CHILD_ITEM_REF value="TEXT_ITEM_2" />
                                                <bi:COLSPAN value="1" />
                                                <bi:HALIGN value="CENTER" />
                                            </bi:COLUMN>
                                        </bi:ROW>
    <bi:TEXT_ITEM name="TEXT_ITEM_1" designheight="70" designwidth="200" >
                                        <bi:TEXT_BINDING type="CHOICE" value="TEXT_CONTENT" >
                                            <bi:TEXT_CONTENT value="TOP" />
                                        </bi:TEXT_BINDING>
                                        <bi:TEXT_DESIGN value="EMPHASIZED" />
                                        <bi:RENDER_AS_TEXT value="X" />
                                    </bi:TEXT_ITEM>
                                    <bi:TEXT_ITEM name="TEXT_ITEM_2" designheight="70" designwidth="200" >
                                        <bi:TEXT_BINDING type="CHOICE" value="TEXT_CONTENT" >
                                            <bi:TEXT_CONTENT value="BAD" />
                                        </bi:TEXT_BINDING>
                                        <bi:TEXT_DESIGN value="EMPHASIZED" />
                                        <bi:RENDER_AS_TEXT value="X" />
                                    </bi:TEXT_ITEM>
    Perhaps you can help me with my code?
    Kind regards
    Tobias

Maybe you are looking for

  • Recording to DVD from DVR

    I used to have Bright House, when a progeam was finished being watched on the DVR an option was to "Record to VCR." (We used the DVD recorder). There is no option like this with FIOS. I called Verizon support (HAHA) and the agent told me - get this -

  • HT4910 photo stream is not putting pictures on my computer

    My pictures are no longer being sent to my photostream folder on my computer.  The photostream folder is on my phone and photostream is turned on in the iCloud control panel on my laptop but the pics will not transfer for some reason.  Help. Thanks,

  • Can't install new mini HELP!

    Could some kind soul give me step by step instructions on how to install my new mini. Having read through some of the topics I seem to have a common problem. My pc will not recognise the new device and consequently it seems the rest of the install pr

  • PDF format

    Hi all, I have a requirement that in the selection-screen i want to put a pushbutton 'Preview'.By clicking it should show a file which is already saved in the desktop of PC which is PDF format. Thank you

  • Treo 700wx calendar not synching

    Hi, I am using a Treo 700wx and have been using it to synch with Exchange for a year successfully.  I recently had a problem that resulted in a hard reset of my phone so I had to reset up the Active Synch options.  Everything but my calendar is re-sy