BI 7.0 Tools for Source System - ECC 6.0

Our company have following version for BI 7.0, before the upgrade (R/3 4.6) and even after the upgrade (ECC 6.0).
2) What is the recmended version of BI tools that can be applied with ECC 6.0 Version. I see some the some of the business Contents are still missing.
3) What is the latest version of BI 7.0 tools we have in the market ?
BI_CONT,      703,  0007
PI_BASIS,      2005_1_700,0013
SAP_ABA,      700, 0013
SAP_BASIS, 700, 0013
SAP_BW,      700, 0015
ST-A/PI,      01J_BCO700,0000
ST-PI,      2005_1_700,0005
Thanks as always
BI

The versions that you have mentioned for ECC 6.0 are quite enough.
Only one thing you have to do is upgrade the support package level to the latest one.
Other than that, it will be well compatible with ECC 6.0 server.
Hope this would help you.

Similar Messages

  • Background job is running for long tome in source system (ECC)

    Hi All,
    Background job is running for long tome in source system (ECC) while extracting data to PSA.
    I checked in ECC system SM66,SM50 the job is still running
    in SM37 the job is Active
    There are only maximum 7000 records the extractor is 2LIS_02_ITM but it is taking 11 to 13 hours to load to PSA daily
    I had checked enhancements every thing is correct.
    Please help me on this how can I solve this issue.
    Regards
    Supraja K

    Hi sudhi,
    The difference between Call customer enhancement...  and  Result of customer enhancement:... is very less we can say this as a second.
    The difference is between LUWs confirmed and 1 LUWs -
       and Call customer enhancement -
    Please find the job log details below, and give me the solution to ressolve this
    01:06:43 ***01:06:43 * ztta/roll_extension........... 2000000000                              *                 R8           050
                     R8           048
    01:06:43 1 LUWs confirmed and 1 LUWs to be deleted with function module RSC2_QOUT_CONFIRM_DATA     RSQU          036
    06:56:31 Call customer enhancement BW_BTE_CALL_BW204010_E (BTE) with 5.208 records                  R3           407
    06:56:31 Result of customer enhancement: 5.208 records                                              R3           408
    06:56:31 Call customer enhancement EXIT_SAPLRSAP_001 (CMOD) with 5.208 records                      R3           407
    06:56:31 Result of customer enhancement: 5.208 records                                              R3           408
    06:56:31 PSA=1 USING SMQS SCHEDULER / IF [tRFC=ON] STARTING qRFC ELSE STARTING SAPI                 R3           299
    06:56:31 Synchronous send of data package 1 (0 parallel tasks)                                      R3           410
    06:56:32 tRFC: Data Package = 0, TID = , Duration = 00:00:00, ARFCSTATE =                           R3           038
    06:56:32 tRFC: Start = 00.00.0000 00:00:00, End = 00.00.0000 00:00:00                               R3           039
    06:56:32 Synchronized transmission of info IDoc 3 (0 parallel tasks)                                R3           414
    06:56:32 IDOC: Info IDoc 3, IDoc No. 1549822, Duration 00:00:00                                     R3           088
    06:56:32 IDoc: Start = 04.10.2011 06:56:32, End = 04.10.2011 06:56:32                               R3           089
    06:56:32 Altogether, 0 records were filtered out through selection conditions                      RSQU          037
    06:56:32 Synchronized transmission of info IDoc 4 (0 parallel tasks)                                R3           414
    06:56:32 IDOC: Info IDoc 4, IDoc No. 1549823, Duration 00:00:00                                     R3           088
    06:56:32 IDoc: Start = 04.10.2011 06:56:32, End = 04.10.2011 06:56:32                               R3           089
    06:56:32 Job finished                                                                               00           517
    Regards
    Supraja

  • Error in code page mapping for Source system whil loading the data from ECC

    HI Gurus,
    I am working in a implementation project, Recently our BI sand box is up, when i am doing my load from 0comp_code_attr it is throwing an error "Error in code page mapping for source system"(This is my first load from ECC).
    In details tab it is showing as the data is sent from the source system but the data is not reaching to the PSA.
    Please let me know if there are any settings needs to be made.
    Many thanks in Advance
    Jagadeesh

    HI V,
    Thanks for your quick response. I did it but it didn't resolve the issue. since the system id which i am having is 3 digits(LEC) but there it is taking only 2 digits, so i clicked on the button called Propose system ids, it has praposed LE, but the issue is stil there.
    Do we need to do any settings in LBWE??
    Thanks and Regards
    Jagadeesh

  • RSAR2318 : IDoc type for source system T90CLNT090 is not available

    Hi all,
    I am working on BI + ECC 6.0. Have created a ODS object using RSA1OLD. While activating the ODS, am getting this error:
    1. Error:
    R7I028
    Object could not be activated
    2. Error:
    RSAR238
    IDoc type for source system T90CLNT090 is not available
    Error when creating the export datasource and dependent objects
    Error RSAR238 : IDoc type for source system T90CLNT090 is not available
    I have already checked trx & dtps, but could not find resolution.
    Kindly help me with this error.
    Thanks and regards,
    MS

    M Sharma wrote:
    But how exactly can I create when T90CLNT is not active? Help please.
    Yes, you would need to check with BASIS team how they have created an alternate source system (for debugging) & prepare a RFC b/n these systems. Can you just check the settings in the source system and BI source system...and check the source system for the same BI system. Right click > Check and then do a restore or take the help of basis to fix it. What I think is a possible solution is : RSA1 > Source system > Search System > Right Click > Activate

  • RSAR238 : IDoc type for source system T90CLNT090 is not available

    Hi all,
    I am working on ECC 6.0. Have created a ODS object using RSA1OLD. While activating the ODS, am getting this error:
    1. Error:
    R7I028
    Object could not be activated
    2. Error:
    RSAR238
    IDoc type for source system T90CLNT090 is not available
    Error when creating the export datasource and dependent objects
    Kindly help me with this error.
    Thanks and regards,
    Dhanapal

    Hi,
    Check the same in SDN..
    Object ZDUMMY could not be activatedMessage no. R7I028
    Re: DSO Activation problem
    http://sap.ittoolbox.com/groups/technical-functional/sap-bw/test-cases-for-module-human-capital-management-1425016
    http://sap.ittoolbox.com/groups/technical-functional/sap-bw/idoc-type-for-source-system-t90clnt090-is-not-available-message-no-rsar238-1431565
    Thanks
    Reddy

  • Error in codepage mapping for source system

    Hi Experts,
    I am getting the following error while loading data from ECC only for Account COPA datasource.
    Error in codepage mapping for source system. Error text:
    Message no. RSDS_ACCESS013
    Regards,
    Sandeep Sharma

    Hi Sandeep,
    This is a issue related to idocsRFC connections from teh sourcesystem....
    U can contact ur BASIS team to solve this...
    From their end they have to chk the unprocessed/errored idocs in BD87...
    They have to run a report:RBDAGAIN to process the errored idoc's in the source which are in STATUS:'02'.
    This is a solution for temporarilrly basis...
    If this occurs regularly they have to change the settings in SM59 which is so important...
    Refer exact note for this: 784381
    The SAP note 613389 may also be relevant for the error message "Could not find code page for receiving system", please check the information given in the note and see if you can use it to resolve the problem.
    Regards,
    Marasa.

  • Issues on Sources System ECC and BI

    Dear Friends,
    I ‘m trying to get data’s (extractions) from ECC 6.0 QA 110 to BI DEV 100. But I only have the Source System to the ECC 6.0 DEV without any data, this connections is working very well. I asked the Basis Consultant to do another connection of the BI DEV 100 with the ECC 6.0 QA 110 using RFC connections with Bitemote with sapall,  between ECC and BI.  He already did it and I can see at SPRO under SAP NetWeaver > SAP BIW > Links to Other Systems > General Connection Setting > Assign Logical System to Client, on both sides in BI and ECC. The question is, do I need to do Any configuration at the BI side to active (create?) this new Source System ECC 6.0 QA 110? I hope I’m clear. Thanks in advance.
    Antony

    Hi Frank,
    I can't imagine any issues compared to other installations. The only thing you need to take care about is that in BI you can only work in one client and in your ecc system you can have multiple clients to work in. These will be treaten as different source systems for your bw.
    regards
    Siggi

  • Error in code page mapping for Source System

    Hi All,
    We are Loading data into BI system from MDM System.
    It was loading fine but Yesterday we got an error " Error in code page mapping for Source System"
    Message Class: RSDS_ACCESS 13.
    We alreday tried to Search any IDOCs with error/unprocessed , but there isn't any.
    Any pointers for this error will be Helpful.
    Regards,
    Mayank

    Our SP currently SAPKW70019 , the SAP note mentioned above required to apply SP for 13, which we already beyond that...unfortunately we still face the same problem .. almost every day ..
    any advice.. ?
    Edited by: Edi Erwan  Abu Talib on Jun 22, 2009 8:22 AM

  • Initialisation option for source system in schedular tab

    What initialisation option for system in schedular tab signifies? Does it acts as pointer and points to the last record loaded in cube or ods?

    Hi....
    Welcome to SDN..........
    Initialisation option for source system in schedular tab........
    shows to you all the init you made for a specific datasource/sourcesystem...if you find a row here, it means that the init channel is active and you can load delta for that specific flow.....
    Initialization may with data transfer or without Data Transfer.......If you do with data transfer it will set the init flag............as well as it will fetch the data from set up table...........if you do without data transfer it will only set the init flag.....it will not fetch any records.........As soon as this init flag get set.......delta queue will get generated in the source system........after that any changes or new records will go to the delta queue.............So initialization load will be followed by delta load......
    When you have to reinit, first of all you have to delete this row and then request a new initial load, otherwise the system cannot allow to perform a new init (with overlapping condition) if you don't deete the previous one....
    Hope this helps
    Regards,
    Debjani.......

  • How to design EDW for source systems from different Time-Zones

    How to design EDW for source systems from different Time-Zones?
    Suppose IT landscape has a global BW in New York, and source systems in americas, europe and asia, then how the time-zones effect on time related things like delta selections on date or timestamp etc.

    As you said BW is global in NY, your source system must be global too. People from various locations can connect to same source system and thus timestamps for delta is always maintained as 1 single time. We have same scenario in our project. Our R/3 system is used by users in US and Europe. So we run deltas twice in day to make sure we got deltas from both locations.
    If scenarios was such that all locations connect to separate R/3 system, then obviously you have multiple queues. That is unique delta queue for each source system so deltas will be pulled as per data in respective queues.
    Abhijit

  • Error in codepage mapping for source system. Error

    Hi BW Experts,
    I am facing following error:
    Error message: Error in codepage mapping for source system. Error text:
    Details: Inbound Processing ( 1000  Records ) : Errors occurred
                Error in codepage mapping for source system. Error text:
                Update PSA ( 0 Records posted ) : Missing messages
    I repeated the delta working and everything fine.
    Does anybody know why this error occurs?

    Run rsa13 (for bi 7.0) find your source system which one you are using for data transfer and double  click on it and find special options there select  the optioned i mentioned already.
    Please search SDN you can fin threads related to this thread
    if not let me know.
    Regards.

  • Error in codepage mapping for source system. Error text:

    guyz,
    im facing the below issue in prod.
    Error in codepage mapping for source system. Error text:
    Message no. RSDS_ACCESS013
    Collection in source system ended
    Error message during processing in BI
    Diagnosis
    An error occurred in BI while processing the data. The error is documented in an error message.
    System Response
    A caller 01, 02 or equal to or greater than 20 contains an error meesage.
    Further analysis:
    The error message(s) was (were) sent by:
    Inbound Processing
    Procedure
    Check the error message (pushbutton below the text).
    Select the message in the message dialog box, and look at the long text for further information.
    Follow the instructions in the message.
    need your guidance,
    cheerz,
    raps.
    Edited by: raps on Mar 1, 2012 9:39 AM

    Hi ,
    Kindly go throught the following threads for your issue resolution::
    Error in code page mapping for Source System
    Erroe in source system
    Regards,
    Arpit

  • Initialisation options for source system

    If I am in an InfoPackage and seleet the option "Initialisation options for source system" and have more than one entries, is there any way that I can delete just one of the entries? Thanks

    Hi there as a test scenario I am trying to delete one entry but it deletes both giving a message as below pre deletion, what am I doing wrong? Thanks
    There are active init selections in source system for this data source
    Therefore, only ALL init selections can be deleted at once
    Do you want to delete all init selections (all channels)?

  • Deletion of request from init option for source system

    Hello Experts,
    Iam using 3 IP.
    IP for init load with data transder, IP for init load without data transfer & Delta.
    now with data transfer IP is not used.
    i trigered "without data transfer IP", then accidentally "triggered with data transfer IP".
    then manually made the request red & deleted data by right clicking datasource-->manage & deleted all the requests(2) available.
    now before i load init without data transfer request exists in "init option for source system".
    when trying to delete IP
    "There are active init selections in source system for this data source. Therefore, only ALL init selections can be deleted at once. Do you want to delete all init selections (all channels)?"
    when i choose yes....it takes a long time & gives run_time error status.
    Guys, this issue is solved.
    I deleted the without data transder first.
    now when I load delta, I got error.
    "Job terminated in source system --> Request set to red"
    regards
    KV
    Edited by: K V on Apr 10, 2009 2:16 PM

    Hi KV.........
    U r doing init without data transfer..............it means it will not pick any records...........it will just set the init pointer and along with that Delta queue will get generated.........after that whenever any changes will be done.........or any new records will come.......it will get reflected in the Delta queue.......
    So next time when u run the delta load..........data will be fetched from the Delta queue...........
    So check the delta queue.......it may happen that there r no new or changed records..................
    So check............may be delta queue is 0..............
    Also check the update mode for the datasource in LBWE(if Logistic datasource)............if the update mode is Queued delta or unserialized V3 update........then data will first get accumulated in the Extract queue(LBWQ) or update table respectively.............so to fetch records in the Delta queue u hav to schedule the V3 jobs in LBWE............otherwise Delta queue will be empty and fetched records will be 0........
    Regards,
    Debjani......

  • Initialisation option for source system

    Hi Gurus
    Can anyone explain clearly about
    Initialisation option for source system
    Thanks in advance
    Raj

    Hi,
    This option is used when you want to init / re-init delta loads from source system (R/3 or BW Datamart). You have to set-up your Initialization before you can run your deltas.If you have already deltas loaded or want to load deltas from source you have to do an init load. In case you have already loaded deltas you have to delete the existing Init Request from your data target and perform re-init.
    You have two options Init with data transfer and without data transfer.
    Init is just setting path for deltas to follow.
    Steps for Re Init from R/3 to BW
    1)Delete the contents of Application area 11 inRSA7 delta queue/LBWQ
    2) Delete the setup table for the application 11 in LBWG
    3) Delete the initialization information in BW , By deleting the 'initializing option for source system ' from infopackage(delta initialization).
    4) Delete the PSA and data in Datatargets.
    5) Fill the setup table for the application 11.
    6) Execute the delta initialization infopackage for these Datasources.
    Thanks,
    JituK