Block the authorization in QM results recording

Hi All...
I am a QM consultant ...Have some problem reg authorization...
we have 2 level of authorization in QM module.
Where 1st level is only allowed to record the results, they should not be allowed reopen the closed results and edit the result. This we tried to do by using the result record status (Tcode for results recording QE01). but not able to restrict the users. the thing is when user enter the result and after doing the valuaiton & closing the status becomes - 5. after that the user should not be allowed to reopen means status - 2. How to do it???
Please share some inputs....
srini

Hello Srinivas,
For the inspector to valuate the result he needs authorization of value 3 for QESTATNEW, for closing he needs value 5 for QESTATNEW and for putting in process he needs value 2 for QESTATNEW.
Similarly, the initial status should be 1, 2, 3, 5 & 6 for successfully completing the operation.
Say, if the he does not have 3 for QESTATNEW then the valuate button (balance) will be disabled so he wont be able to change the status of the characteristic to 3.
If he does not have 5 for QESTATNEW then the close button (closed lock) will be disabled so he wont be able to change the status to 5.
If he does not have 2 for QESTATNEW then the put in process button (open lock) will be disabled so he wont be able to change status of the characteristic back to 2.
I hope I have cleared your doubt.
Regards,
Subbu

Similar Messages

  • Overwriting results in QE51N (results recording)

    Hi all,
    I have a situation here whereby we allow QM users to enter the results accordingly per sample lot in each inspection characteristic.
    Right before we perform UD, the QM manager would like himself only to have authorization to overwrite the values entered in results recording only. Is it possible for us to use this authorization object Q_CHAR_PRC to control? Or should we use user profile instead?
    Appreciate the advice thrown out. If there any questions, do let me know too!. Thanks!

    Hi Gajesh,
    Thanks for your reply. Could you advise what values I am able to maintain in the object Q_CHAR_PRC? I can only do SU53 screen but no access to authorizations even PFCG.
    What I can see now in my SU53 screen when I hit error is QESTATNEW = 5 and QESTATOLD = 3 and it also checks against the work centre and plant code.
    Thanks for your advice.

  • Usage decision vs result recording.

    Hi All Guru,
    I am new in QM , was MM & PP support. I am confused here about the usage decision vs result recording.
    I do understand in QM there's inspection lot , in order to release the inspection lot , i should released the UD.
    So what's the different between this both ?
    Can i have inspection lot without result recording ?
    Or can i have inspection lot without UD ?
    Please help to clarify my confuse.
    Thank you

    Hi Crag ,
    Thanks for understand because i am totally new in QM.
    I won't use QM for Notification here. I will use QM for stock transfer & QM in Delivery before PGI.
    As i know the basic requirement of QM 
    Setup the Master Data (QM View & all QM relavant data) ---> Type of inspection (which will determine which type of inspection to carry out ) -----> Inspection Lot Configuration --->Configuration for UD ----> Configuration for COA.
    Master data that which required
    Material master QM view,
    Master inspection characteristics,
    Task lists or inspection plans
    Code, Code groups and Selected sets.
    Quality info-record
    My Question :
    By having the above setup and configuration , without result recording can i have the COA to print out for either Post Process Inspection (Final FG) or Inspection at Delivery ?
    With the Master Data which i mention as above , is it sufficient for me to activate
    Post Process Inspection (Final FG - QM PP)
    QM Inspection at Delivery (QM /SD)
    QM stock transfer with inspection type 08.
    Hope to hear from you.
    Thank you

  • Displaying long text maintained for selected set codes in result recording

    Hi Gurus,
    I have maintained qualitative mic.For this mic i have defined selected set codes & for these selected set codes i have maintained long text.
    My client requirement is that this long text should be visible while doing result recording for the mic.Is this possible.
    Regards
    Amit

    How can they expect that?  Long text can be... well.. long.......  How can you include that on the same screen as results recording.  What if you have 5 charac with long text?  What if each selected set choice has long text and you had two choices for each?  That's ten sections of long text on one screen?   Impossible.
    Printing the long text on the cert shouldn't be a problem.  You just have to get someone to code it into the layout set.
    Craig

  • Preventing UD without results recording

    HI,
    We are able to do force closing of the inspection lots without results recording by registering the UD directly. How to prevent this? i.e. we dont want to register UD for lots without result recording for all the characterisitics. With User status we cannot achieve this because if we register results for some characteristics also the system status will be updated.
    Regards,
    Ravi Kumar C.

    hi
    yes as Mr.Shyamal mentioned, you can get through User status and in MIC slect the Required Characteristic radio button on control indicators,
    If you set this indicator, the inspection characteristic must be inspected.
    This means that you can only make a usage decision for the inspection lot after you have confirmed inspection results for this inspection characteristic.
    -pl check
    -ashok

  • QM-result recording after doing usage dcision and stock posting.

    HI gurus,
    My client is steel manufacturing industry.The requirement of client is that, after doing usage decision and stock posting they want to do result recording.Thy want it like this because in case of urgency they pass the material and afterward they do the result recording.Is such a scenario is possible in standard sap.If yes pls. provide me the solution.
    Thanks in advance.

    I wouls suggest you look at Jan's suggestion.  Setting everything as LT characteristics is
    1) not a good quality practice
    2) you would still have to manually to the UD I believe, auto UD won't work.  So if you have to manually process the lot anyway, you may as well just make the sotck posting and leave the lot open for results recording.
    Craig

  • How to see MIC number in Result Recording Screen

    Hi,
    During result recording  (thru QE51N/ QA32 ) in result recording screen we see MIC short text but not the MIC number.
    How to get the MIC number during result recording screen?
    Already we have used Info Field for this & get the MIC number Directly in result recording screen but User like to go for other option.
    Thanks in advance.

    I  think  you wont get MIC no instandard SAP

  • Status profile for Result recording & UD

    Hi
    I am using a status profile for restricting the UD (QM_L_004)without result recording. The stages are INIT and QFIN with the required settings.
    But users even after doing result recoding are getting an error while choosing the UD code. The error is Close Inspection - Complete. I have maintained this status on QFIN as ALLOWED and SET. I checked for authorisation (SU53) and found that it is giving for Object category QL1 for status profile ( QM_L_004).
    I request you all to please give me the details on this object category. Where it is linked & also should i extend the other object category QL2, QL3 and what will be its effects.
    we have issue of people not attaching MICs in inspection plan and giving only UD. I want to address this issue also
    Thanks In advance

    Dear,
    Suppose status no. for 1st one is 10 and for next one is 20. so for 1st one you put lowest and highest value 10 to 10. same way for secone one put 20 to 20.
    Now initially 10 is active now for second status put set when RR staus has acieved. In the same prohibit UD. Means select that button in which it does not allowed. This setting is only for status no. 10.
    Now setting for second status press set button wheen RR done. So it will get activated when RR done. Now in this select UD allowed radio button.
    Do this way, it will work.
    Regards,
    Kaushal Rai

  • Results Recording Work List By Work Centre

    Experts,
    My Inspection Plans have two work centres.
    Can I run a report which lists how many results (not UD) each work centre has recorded on a particular day?
    Thanks
    Welshy

    Hi,
    Quite unique and interesting!
    As per my knowledge there is no specific standard report for this. You may have to go with work around- Z report for this. I do have a suggestion. Just check whether feasible.
    1.     The date on which result recording is carried out gets stored in QAMR table. The field is QAMR-ERSTELLDAT.
    2.     Work centers 2 in number, means you are dealing with 2 operations.
    3.     The main task here I think, is to correlate inspection lot number with its work centers which is quite cumbersome, even if you try to link QALS, PLPO, CRHD tables with each other.
    4.     Node number in table QAMR (field VORGLFNR) is nothing but operation number. Instead of work center if you go with operation number as input, may serve the purpose.
    5.     Give input as inspection lot number, date of result recording QAMR-ERSTELLDAT and operation (optional)
    6.     For the given input date if you find any data in QAMR, you may conclude RR is carried out on this date.
    7.     Rest of the details (material code, material description, vendor etc) you can very well fetch once you know inspection lot number.
    Regards,
    Anand Rao

  • Activating defect class during result recording.

    Hello Friends
    I have created Defect class with few codes, during result recording defect class is 'GREY' not allowing to select code (only display).
    I want it's should be available so that one can choose the relevant code from defect class whille doing result recording.
    Kindly provide your expertise comments to do the same.
    Regards
    Swanad

    Dear Swanad
    Please do the following setting
    In Result recording screen  > Go to Setting (Menu button ) > Defect Class on
    By doing this when you do result recording and the reading is out of spec then after the valuation pop up defect class will get popped up. You can select any one of the defect class
    Regards
    Gajesh

  • Single Result Recording

    Hi Experts,
    I have a scenario where the MIC should be created for single result recording, but user wants to record less number or results in system . This can be achieved by putting either no scope or less scope.But once we record a less number, grays of the Inspected samples to lesser number according to the sample results entered.
    The requirement is Single result recording, but the inspected samples should be able to be modified irrespective of the no. of results entered.
    For egs.
    Sample size to inspect: 100 (single values)
    User enters values for only 5 out of 100.
    But user should be able to specify the Inspected samples  as 100. (this is because in this scenario they would record only the results out of spec results, if in spec.results they don't want to record the results data)
    Alternate is to use Summarized result recording, but it does not allow to record individual records for these out of spec. results.
    Thanks
    Jomy

    dear jomy
    Seems difficult. tried with lot options not working. Wait for experts comments
    regards
    gajesh

  • Employee ID & Password at the time of Results Recording

    Hi Gurus,
    At the time of results recording there is a need of entering employee id, password & some additional text. Is it possible?
    Thanks in Advance,
    Sandeep

    Hi
    Use digital signature for this scenario.  SPRO > Envt>Central functions>Auth.Mgt>Dig Sign. In this signature method for results recording.  All this linked with Material Authorization Group in MM-QM View. Read more on digital signature. You will get the solution.

  • Want to change the Result Recording Result

    Hi All,
    I have a problem Please help me out or suggest me is it possible to do-
    Result Recording is done and saved for a particular lot and result is accepted and i did UD for that and accepted as well as i posted to un-restricted stock with Acceptance and saved.
    Now my client want to chance the result and reject it and post it to blocked stock again do UD.
    This is our normal requirement here.
    Regards,
    siddharth shanker

    Hi,
    You have to explain your  client the process and its pros and cons, once you give UD and post the stock then how will that be canceled. Keeping apart SAP, in actual domain practice also  when you accept the lot you can't reject it on same challan, you have to so separate process.
    Here best way is to assign 08 Insp type to that material and create the lot using 322 movement type (MB1B) and again reinspect and post it to block and send back to vendor. This is only if you need to record results again, otherwise you can directly post from unrestricted to Block stock using movement type 344 i.e. from unrestricted to block then purchase person will send it back to Vendor. You can raise notification to keep record of this movement.
    Best Regards,
    Shekhar

  • Error While saving the tabulator results recording(QE71)

    Hi Experts ,
    through the Tcode QE71 i'm recording the inspection points and the inspection results but while Saving the recorded results , the system is giving error as " No Orignal values " and also as "inspection Pt 99999 of the Characteristics .....is not avaialable".
    What might be the possible reason for the same. But when i'm entering the results through the Tcode QE01 all the results are saved and closed.
    Can anybody help me out of this.
    B'regards
    Krishna

    Hi,
    Can you call your web service using jQuery not in an app successfully?
    As the error message suggests, it might be an error on the server side.
    I suggest you do a simple test to check whether you can call the web service using jQuery.
    Here are two links would provide more information about troubleshooting this error for your reference:
    http://sadomovalex.blogspot.com/2013/08/return-json-from-asmx-when-call-it.html
    http://www.codeproject.com/Tips/761116/Troubleshooting-an-Issue-With-Calling-an-asmx-Web
    Feel free to reply with the test result if the issue still exists.
    Best regards
    Patrick Liang
    TechNet Community Support

  • Result recording resukts are not reflecting in the batch

    Hi,
    I have one query which i am unable to get thrgh
    I have recorded the characterstics results in the results recording ,The recorded results need to reflect into the batch(MSC3N)
    What is the procedure to follow
    Please help me out
    Regards,
    Sravanthi

    Hi
    Steps Followed,
    u2022 Creation of class Characteristic (CT04)
    u2022 Creation of Batch Class (CL01)
    u2022 Assignment of above created classed characteristic to the Batch Class at the time of class creation. (CL01)
    u2022 Assignment of batch class to material master in classification view. (MM01)
    u2022 Creation of MIC with reference to above created Class characteristic (QS21)
    u2022 Creation of inspection plan with above MIC (QP01)
    u2022 Creation of new batch (external numbering) for the material (MSC1N)
    u2022 Creation of manual lot for 89 lot origin (QA01)
    u2022 Result recording and usage decision (QA32)
    please refer
    Re: QM_Class Characteristic
    Regards
    Sujit

Maybe you are looking for

  • I have over 19,000 pics on my Mac. Only 4,000 are showing up in the cloud. How do I get all of my pics on the cloud? I have purchased the storage

    I have merged my iPhoto and Photo app. I have over 19,000 pics on my Mac but only 4,000 are showing up in the cloud. I added some pictures yesterday to my Mac that I had taken, but they do not show up on any of my other devices. What is wrong?

  • LIRC - 100% cpu usage while pressing a button

    Hi all. I'm having some problems with latest lirc versions. It just uses 100% of my cpu while I press any key on the remote. For example, with xbmc, pressing a remote control button makes a one second video lag and frame dropping due to high cpu usag

  • Image layout

    Hi Quick question...im wanting to have an image on a page, with text next to that image not underneath it. I am currently using a simple two column one row table, with the image in one box and the text in the other which is ok. Wondering if anyone ha

  • Deploy project with Ethercat

    Hi All! I need some help. I created a project which is made of two parts. The host run on a Standard PC (display HMI...) , the second part works on a PXI controller (RT) linked to a 9144 Ethercat. I debugg my project and everything works perfectly, I

  • Bug in windows 2012 server?

    Hello. I have the following configuration: 27 win 2012 servers with HV managed by one of them (let's say HV02) via Server Manager. If i select one of them (HV03 - let's say) from the 'All servers' group and i click on Tools -> Services, I should get