BMR hints? W2k8r2 BMR from Dell Poweredge T310 to different Dell machine

Hello,
I've seen some other questions about this problem, but haven't read any responses that quite help me get to the other side of the problem I'm having.
I have a situation where I need to restore a bare metal backup from a Dell PowerEdge T310 server to an off the shelf computer.  It fails, of course, and I'm stuck about what's causing the failure so I can try to remedy it.
Both machines have the same storage space.  The T310 utilizes DELL PERC 6/i Adapter and contains 3 500 GB drives.  The other machine does not have this hardware.  I'm wondering if this is the trouble.
I was able to successfully restore this server, without any trouble whatsoever, to an old Dell OptiPlex 330 workstation with a single 1TB drive, but cannot get the same result when a Dell Inspiron i7 is used.
Both machines are ACPI x64-based PCs.
Do you think it's the missing PERC that's causing the problem?  From your experience, what are all the not-so-obvious things I should check? 
The fact that I can do a BMR to an old OptiPlex is amazing.  I didn't expect any problems with the new computer.
Thanks in advance for your assistance!
Beth

Hi,
We do not support restoring a system state backup from one computer to a second computer of a different make, model, or hardware configuration. We only provide commercially reasonable efforts to support this process. Even if the source and destination
computers seem to be identical makes and models, the source computers may have different drivers, hardware, or firmware than the destination computers.
According to your description, the two server have different RAID controller. BMR between the two servers will cause BSOD or system not boot issue.
How to: Bare Metal Restore of SBS2008 to different hardware with a different RAID controller?
http://social.technet.microsoft.com/Forums/en-US/019a504e-c109-4d18-a85f-4f03944ada05/how-to-bare-metal-restore-of-sbs2008-to-different-hardware-with-a-different-raid-controller?forum=windowsbackup
Regards,
Mandy
We
are trying to better understand customer views on social support experience, so your participation in this
interview project would be greatly appreciated if you have time.
Thanks for helping make community forums a great place.

Similar Messages

  • Dell PowerEdge Servers with non-dell storage

    yes I do I have a few 2950's that I run with WD red drives they work fine. moslty that stuff is to keep warranties upheld and to keep repeat customers coming back. its up to you how much you want to deal with. some of the raid functions and raid configurations may not be available if they have custom firmware from Xbyte or require custom firmware installed.personally if the server hardware is past dell's warranty I am using the cheapest most reliable drives I can get my hands on because at that point its on me any way. that also means wiping the PERC controller to default and rolling with default settings and then modifying them to what I need.Then again it goes back to how much responsibility do you want on you for this hardware. if you want as little as possible play by your distributors rules and have little or take it all yourself...

    Hi,
    I am pricing out some refurbished Dell PowerEdge servers primarily from xbyte.com and received feedback from them that they are extremely apprehensive about using non-dell storage in the server due to the custom firmware in the drives themselves. That being said they offer non-dell hard drives with custom xbyte firmware which apparently work... and yet they will still report a non-mission critical error in the manager.
    Does anyone run production servers with 3rd party drives? If it is not recommended to do so, does anyone run the "Xbyte drive firmware" in production servers?
    Thanks!
    This topic first appeared in the Spiceworks Community

  • Upgrade to Lion from Snow Leopard using a different time machine disk

    Hello.
    I have just purchased a new 2011 iMac which has got OSX Lion (10.7.2) installed on it. I have set up all my basic data on it. And I have set up 3 administrator user accounts on it to be shared between me, my dad and my wife.
    I also own a 2010 Mac Mini with HDMI connected to my television which has the Latest Snow Leopard OSX installed in it. It has only a single user - me.
    So that leads to the following questions:
    1) Is it possible to take a time machine backup of the new iMac which has Lion and use it via the migration assistant on the Mac Mini (Snow leopard) to upgrade the mac mini to Lion and have all my settings on the iMac on the mac mini?
    2) Will there be any compatibility issues of transferring from iMac to Mac Mini?
    3) Will i get my 3 administrator user setup on the mac mini as well in case above is possible?
    Thank you for any help and advise.

    Quick answers.
    1. no
    2. yes
    3. no
    Your only option is to install Lion onto the mini and then set up the other accounts.

  • Problems installing Solaris 10 on Dell PowerEdge 800

    Hi,
    I am experiencing some trouble when I attempt to install Solaris 10 on a Dell PowerEdge 800. It is equipped with two RAID disks controlled by a Dell CERC SATA 1.5/6ch (according to the BIOS).
    The installation program reports that it cannot write to the disk. This happens when it is about to start installing files. Tried setting it to a single volume and disable RAID. Same thing. Read another article saying something about disabling IDE, well it doesn't seem to help ...
    Any hints?

    I have the same problem on a dell 750 with the SERC controller. I can add some more information but if you get a solution I would appreciate the detail.
    1) If I install Solaris via the SERC in RAID 1 mode then the alarm on the SERC goes off as soon as I start to write to the disk.
    2) I bypassed the SERC and installed on a single disk straight off the motherboard. Time the install crashed at the same point but this time the error message told me that the first available cylinder was number 3! Ah
    3) I reconnected the disk via the SERC, rebuilt the RAID array and made a mistake. I created a RAID 0 (striped) array and installed the software starting from cylinder 3. I got a complete solaris install that rebooted fine and is fully working.
    BUT I NEED A MIRRORED SYSTEM SO
    4) I rebuild the machine again this time RAID 1 and again the crash occured at exactly the same point i.e. as soo as I start to write to the disk.
    Whether or not DELL / Adaptec support Solaris should not be an issue. This is a BIOS configurable RAID controller that can be fully serviced (e.g. disks replaced) from the BIOS. The system sees the array as a disk via the controller and indeed it is seeing it.
    The SERCs own data configuration data should be on sectors which are not visible to solaris VIA the SERC so we shouldnt be able to damage them but I suspect that this may not be the case.
    I suspect that the answer is in the partition layout and who or what creates them (I dont mean the Solaris slices but the FDISK partitions)
    To make matters worse, since I need the machine working I went back to disks straight of the motherboard and configured again and used metadevices to set up a fully mirrored systemas I have done many times before on sparc (but never on Solaris x86)
    This worked fine but I thought that I would test bootability in the event of disk failure. There isnt any!
    if disk 1 fails then the motherboard wont accept disk 2 unless you swap the cables and move it do disk 1 and by then the boot sectors are wrong for the address of the device. I can probably solve this by building both disks in slot one but who wants a mirrored server that you have to open up and move a cable when the disk fails. I think I may have to ditch SATA and go back to SCSI !

  • Solaris 8 installation problem on Dell PowerEdge 500SC

    Hi,
    I am having TWO PROBLEMS installing Solaris 8 on Dell PowerEdge 500SC.
    This hardware spec is:
    Pentium-III at 1GHz
    256MB 133MHz ECC SDRAM
    20GB 7200RPM ATA100 EIDE hard drive (on integrated ATA-100 controller)
    48X EIDE CD-ROM drive (on integrated ATA-100 controller)
    Motherboard: unknown
    more details: http://www.dell.com/us/en/esg/topics/esg_pedge_sc_towermain_servers_3_pedge_500sc.htm
    FIRST PROBLEM is the following message was shown at the hardware probe.
    WARNING: ACPI Tables not in Reclaim Memory
    Warning: Resource Conflict - both devices are added
    NON-ACPI device: PNP0C01
    Port: C00-C01, C06-C08, C14, C50-C52, C6C-C6F,
    CD6-CD7
    F50-F57
    ACPI device: PNP0C01
    Port 814-85B, 580-58F, C00-CD7, F50-F58
    At this time, I was using "Solaris 8 (Intel Platform Edition) 10/01" released version.
    I am not sure what this means, but it was RESOLVED with using newer "x86 DCA boot diskette (Patch-ID# 110930-05)".
    But, the SECOND REAL PROBLEM is another one. It just happens booting the kernel after the hardware probe. I get the following messages about 2 minutes later, after beginning to load kernel.
    WARNING:/pci@0,0/pci-ide@1/ata@1 (ata1): timeout: abort request, target=0 lun=0
    WARNING:/pci@0,0/pci-ide@1/ata@1 (ata1): timeout: about device, target=0 lun=0
    WARNING:/pci@0,0/pci-ide@1/ata@1 (ata1): timeout: reset target, target=0 lun=0
    WARNING:/pci@0,0/pci-ide@1/ata@1 (ata1): timeout: reset bus, target=0 lun=0
    After another 1 or 2 minutes I get more error and the system reboots.
    Please give me any suggestion or advice!
    Thanks.
    Kazuyoshi

    I've been having the exact same problems on a PowerEdge 500SC. I have managed to get Solaris up and running on the machine, however. I booted the DCA from the floppy disk and installed from the CD-ROM. When the DCA is ready to scan for devices I use the "Specific Scan" option to tell it to look for specific devices. I tell it to scan for all devices in the listing and in doing so the DCA finds ISA-based IDE controllers. After it provides a listing of the devices it found I use the "Device Tasks" option and the "View/Edit Devices" menu item then delete the Bus Mastering IDE controller device. Once the screen comes up to ask for a boot device, the drives will show up as on the ISA controllers.
    I have to go through this process every time I boot the machine but I am able to make the system run at least.
    I haven't figured out the ACPI problem, yet.
    Regards,
    Doug

  • Problem with Installation on DELL Poweredge with Hardware RAID 1

    Hello Arch LInux community, 
    I am a newbee with good linux knowledge of working on linux but not much of systems administration. I am very much interested to install Arch Linux on my new desktop which is a Dell poweredge having hardware RAID 1(PERC .... controller). It has windows 7 OS on its first partition.
    I saw on the controller's BIOS menu that there are 2 1tb hard drives with something like --:--:00 and --:--:01 labels. And they were partitioned into two logical volumes which are visible once I boot into Arch linux live CD as, /dev/sda (about 250GB, and has windows OS on it) and /dev/sdb (about 700GB).
    Firstly, I am confused with the hard disk labels: even though they are logical partitions (i.e: combined by RAID 1, they are seen as /dev/sda and /dev/sdb). In the arch linux Beginner's wiki, there is some description on configuring for RAID, which included mdadm or mdadm_udev module specification. I did include these modules, and followed the installatin instructions carefully. I was trying to install on /dev/sdb, with the following partitioning:
    Sector map of partitions on /dev/sdb  : 1542848512 : 735.7 GiB
    Disk identifier (GUID) : 967BF308-6E5E-43AD-AB2E-94EB975C3603
    First usable sector = 34 Last usable sector  = 1542848478
    Total  free space is 2023 sectors
    Number        Start    End                  Size             Code    Name
                      34    2047                     FREE    
    1               2048    2099199        1024.0 MiB    EF00            EFI System
    2          2099200    2103295         2.0 MiB    EF02      BIOS boot partition
    3          2103296    2615295         250.0 MiB    8300      Linux filesystem
    4          2615296    212330495         100.0 GiB    8300     Linux filesystem
    5       212330496    317188095      50.0 GiB    8300     Linux filesystem
    6       317188096    1541924863    584.0 GiB    8300            Linux filesystem
         1541924864     1542848478                         FREE    
    The instruction on the Beginner's wiki is somewhat difficult to understand for beginners. Especially I wasn't sure whether to make EFI System partition and BIOS boot partition or just EFI system partition. So I made both as per the instructions.
    Is using UEFI compulsory, on UEFI based systems?
    A little bit more sub-headings or division of instructions, in the Beginner's wiki,  based on the usage scenarios can be very beneficial for newbees like me.
    I am finally getting the following error when I select the Arch Linux from the GRUB menu. Why it can't find the device?  I shall wait for your initial responses, and will give more specifics of my installation to find out any wrong step that I may have made.
    [ 0.748399] megasas: INIT adapter done
    ERROR: device 'UUID=40e603e9-7285-4ec8-8a06-a579358a52a0' not found. Skipping fsck
    ERROR: Unable to find root device 'UUID=40e603e9-7285-4ec8-8a06-a579358a52a0' .
    You are being dropped to a recovery shell
    Type 'exit' to try and continue booting
    Sh: can't access tty; job control turned off
    [rootfs /]#

    Well, you can see your RAID partitions and you're getting GRUB to load, and you are even being dropped to the recovery shell which means that the /boot partition is being found and is accessible. All vary, vary good things.
    I would boot into the Arch live CD/USB again. Then check the UUID of the / Root partition. To do this I just check the log listing of /dev/disk/by-uuid
    ls -l /dev/disk/by-uuid
    Hopefully the UUID for the /root partition in the /boot/grub/grub.cfg is incorrect, and all you need to do is change it from 'UUID=40e603e9-7285-4ec8-8a06-a579358a52a0' to the correct UUID.
    If the UUID is correct... then maybe the correct driver module is not complied into the initramfs. You could try adding that mdadm to the MODULES= list in /etc/mkinitcpio.conf then rebuild the initramfs again.
    mkinitcpio -p linux
    Hum..., the whole /dev/sda and /dev/sdb.... hum, You know... Maybe you need to change the line in /boot/grub/grub.cfg
    set root='hd1,msdos1'
    The hd1 is the equivalent to /dev/sda and the msdos1 is the equivalent of the First Partition i.e. /dev/sda1.. (note this is my disk yours may correctly have different numbers and not be a msdos partition)... owe wait... hum, you know I am fairly sure that like is really the root disk where the /boot partition is and has no relation to the / Root partition... Someone clear that up please.... It is hard for me to recall and I have my / Root parition encrypted, so It is hard for me to make heads or tails of that one right now, but that could be the problem too i.e. try changing hd1 to hd2 or hd0 or something.
    Owe, and it may be faster if you just make temporary corrections to the GRUB menu by hitting the "e" key on the menu entry you want to change then hit.. I think F10 to boot the modified entry. That way you don't need to keep booting into the Live CD/USB
    Last edited by hunterthomson (2012-09-20 05:52:33)

  • Odd netowrking issues on 2 Dell PowerEdge servers

    Hi, we have recently installed two Dell PowerEdge servers both set-up with Windows Server 2008 R2. I used the Dell Systems Management disk to install the OS which pre-loads certain drivers, etc.
    Since the install I have been trying to track down and fix some very strange behaviour with both servers, in particular with MS Exchange 2007 and IIS.
    The issues on server 1 (file server) are no access to Windows Updates (0x80072EE2), certain users on other VPN sites having problems accessing certain areas of our Intranet that require authentication, odd problems using IE on the server - for example
    I can go to Google, carry out a search but when I click on a result it just sits there waiting for Google. There are no issues with users on the same site, and there are no issues accessing the server shares from any site.
    The issues on server 2 (Exchange server) are even more odd and have me rapidly pulling out my hair. With the site we can send and receive between this server and an old Exchange 2003 server with no problems, Public Folder replication from the old server
    to the new is occurring with no problems and we can send messages with large attachments both to external users and users on other sites. However when we start looking at incoming connections this is where it gets odd. Incoming external messages over 4Mb are
    delayed and eventually bounced - our provider says that they are getting timeouts. Incoming messages with attachments from two other internal Exchange 2007 sites are getting delayed and from one sites are not getting through at all. Messages without attachments
    are not getting through at all. In the Exchange logs I am seeing Connection Timeout and Connection Dropped messages.
    I am very sure that the problem is not with message size as all parameter relating to message size are set to 100Mb. I know it is not a firewall issue as redirecting incoming external messages to the old Exchange server is fine.
    To my mind this looks like there is something on these servers which is messing with http/https/smtp when communicating outside the local subnet. I have checked for viruses and mal-ware and for testing purposes disabled AV and firewall but this makes no
    difference.
    I have two other PowerEdge server on another site with similar configurations which have been working fine for 18 months. The only big difference I can see between the servers is that these two are the only one where I used the Dell Systems Management disk
    to install the OS. I have Googled 80072EE2 and it does appear that other have seen the same problem and their way to resolve it was to wipe and reinstall directly from the Microsoft disk and no use the Dell Systems Management Disk.
    However, this is not an option here as these servers are both in a live environment (I know, should have made sure everything was running properly before going live, but these had to be put in place rapidly to replace failing servers).
    From what I can see of the servers it does appear that somewhere along the line Dell have used files which are causing some networking issues on these two servers - can anyone advise me if there is a reasonably straight-forward way to remove the network
    components form the servers and then reinstate from the Microsoft disk?
    I have tried the fixed relating to Windows Update from the suggestion offered searching for 80072EE2.
    I have tried installing the latest Dell drivers for the network adaptor, and also the latest Broadcom ones.
    I have tried switching off various Offload settings on the NIC as suggested by other although that was more relating to Hyper-V issues.
    Anything else I should be looking at, or can anyone tell me what else to look for on the servers?
    Many thanks, Eddie

    Hi Eddie,
    Based on your description, we have many different problems in two servers as below,
    In the file server.
    -> The issues on server 1 (file server) are no access to Windows Updates (0x80072EE2).
    -> odd problems using IE on the server - for example I can go to Google, carry out a search but when I click on a result it just sits there waiting for Google.
    I noticed that you mentioned that you have tried the fixed relating to Windows Update. Have we solved this issue? And another issue, IE could access Google but can’t access
    the links in search result. It seems that this issues are related to name resolution. To verify if the name resolution works fine. Please ping the DNS server at first. If we can ping DNS server, we can also ping
    www.google.com and other domain names to verify the function of name resolution. Please try to use ipconfig /flushdns and ipconfig /registerdns command in server 1. And the DNS port(53) was opened. After this, if the problem
    still exist, please involve the administrator of DNS server to help verify if the domain name resolution has some problems.
    -> certain users on other VPN sites having problems accessing certain areas of our Intranet that require authentication
    I’m a little unclear about this part. If the VPN connection has set up successful, it is possible that the user need be authenticate when the user access some resource of the
    Intranet. So what is the certain areas and what prompt we received.
    In the Exchange server.
    ->Incoming external messages over 4Mb are delayed and eventually bounced - our provider says that they are getting timeouts. Incoming messages with
    attachments from two other internal Exchange 2007 sites are getting delayed and from one sites are not getting through at all. Messages without attachments are not getting through at all. In the Exchange logs I am seeing Connection Timeout and Connection Dropped
    messages.
    -> I am very sure that the problem is not with message size as all parameter relating to message size are set to 100Mb.
    We can send messages but we can’t receive messages, it was delayed or it can’t get through. And I notice that you mentioned that the message size is
    not the problem. To verify if the network have problems about the size messages. We can also download a file whose size is over 5Mb from the Internet. If we can download the file, maybe it’s not the network problems.
    -> I know it is not a firewall issue as redirecting incoming external messages to the old Exchange server is fine.
    Maybe we could also turn off the firewall temporarily to see if the firewall block some connection.
    -> To my mind this looks like there is something on these servers which is messing with http/https/smtp when communicating outside the local subnet.
    If we think the http/https/smtp are related to this issues, maybe we could check if all ports about this service was opened.
    And due to server 2 is an Exchange server, there might be some wrong with the Exchange services. We have the related Exchange forum with professional
    to deal with this issue. If there are still some problems with Exchange server, maybe we can try to create a new thread about Exchange.
    Best Regards,
    Tina

  • Dell PowerEdge SC1420 with Ultra 320 scsi dirves

    I am having a problem with installing Solaris 10 on the Dell PowerEdge SC1420 with Ultra 320 SCSI drives using PERC 320/DC Controller. The installation hangs at Configuring Devices and gives me some output messages:
    NOTICE: MSG From Adapter: NMI ISR: NMI_BUS_INTERFACE_UNIT_ERROR
    NOTICE: MSG From Adapter: NormPrioCommand was received with Fib StructType = 0xf
    The notices keeps cycling.
    Has anyone experience this issue?
    Any suggestions are appreciated.
    Thank you,
    Brian

    Update:
    I've got the box to install Solaris 10, however, I had to remove 2 sticks of memory. Originally, the box came with 4GB of memory but now I am down to 2GB. Don't know why this is the case but I am able to proceed with the installation without any error or notice messages. Can someone explain to me why this is the case? I will put the memory sticks back in and boot with the OS installed to see what happens and will update my results.
    Thanks,
    Brian

  • Stuck Dell PowerEdge 2550 not REALLY supported?

    Hi all,
    I've been trying to get Solaris 8 installed on a Dell PowerEdge 2550 I just got in, and I'm not having any luck. This is unfortunate, as its my one sole server for a small biz I'm trying to get going. Sigh. Anyway, the problem is that after booting off the CD and installing the boot image onto the HD (which seems to go fine), I reboot and it hangs at the:
    Solaris Boot Loader           Version 2.0
    And that's it... can't get to the blue screen boot manager and continue. I've tried the latest drivers from Dell for the 7899, the Ultra160 drivers straight from Adaptec... all for naught. Tried reconfiguring (mostly turning stuff off) on the Adaptec, nada.
    I called up Dell support, who were basically useless. Told me some load of crap about "Well, we can't get Solaris 8 to work on any of our stuff". Which is odd, coz Sun lists this system as a supported configuration, along with a bunch of other Dells. Not to mention the tech on the sales call that told me it would work, along with the built-in PERC3 raid controller. Which doesn't, of course.
    Anyone had a similar problem that they've managed to get around? Otherwise I'll have to call them to come pick it back up. Which'll set me back another 2 weeks, sigh. Anyway,
    Gory details:
    PIII 1.26mhz
    2 18.2GIG Fujitsu drives
    Adaptec 7899
    Built in PERC3/DI RAID controller (currently disabled and completely unsupported)
    2x2 split backplane.
    I've also been trying the Solaris 9 EA install, but I can't get it to configure the jumpstart directory correctly. Anyone have a step-by-step for doing it? Thanks,
    Lucas.

    Lucas,
    We had similar problems with a PowerEdge 1550 a few weeks back, but found that turning off the ACPI settings (see below) and using the latest DCA diskette from the Sun website, everything worked perfectly including the AIC-7899 and dual NIC detection.
    A possible workaround is to disable the kernel ACPI module. If the problem
    is happening during installation, the boot floppy must be modified. Mount the
    boot floppy and add the following line to bootenv.rc:
    setprop acpi-user-options '0x2'
    Run the installation again, ACPI should be disabled and the installation
    should continue without a problem.
    If the problem occurs after installation the same line can be added to
    the top of /etc/bootrc and ACPI will be disabled on the next reboot.
    Hi all,
    I've been trying to get Solaris 8 installed on a Dell
    PowerEdge 2550 I just got in, and I'm not having any
    luck. This is unfortunate, as its my one sole server
    for a small biz I'm trying to get going. Sigh.
    Anyway, the problem is that after booting off the CD
    and installing the boot image onto the HD (which
    seems to go fine), I reboot and it hangs at the:
    Solaris Boot Loader           Version 2.0
    And that's it... can't get to the blue screen boot
    manager and continue. I've tried the latest drivers
    from Dell for the 7899, the Ultra160 drivers straight
    from Adaptec... all for naught. Tried reconfiguring
    (mostly turning stuff off) on the Adaptec, nada.
    I called up Dell support, who were basically useless.
    Told me some load of crap about "Well, we can't get
    Solaris 8 to work on any of our stuff". Which is
    odd, coz Sun lists this system as a supported
    configuration, along with a bunch of other Dells.
    Not to mention the tech on the sales call that told
    d me it would work, along with the built-in PERC3 raid
    controller. Which doesn't, of course.
    Anyone had a similar problem that they've managed to
    get around? Otherwise I'll have to call them to come
    pick it back up. Which'll set me back another 2
    weeks, sigh. Anyway,
    Gory details:
    PIII 1.26mhz
    2 18.2GIG Fujitsu drives
    Adaptec 7899
    Built in PERC3/DI RAID controller (currently disabled
    and completely unsupported)
    2x2 split backplane.
    I've also been trying the Solaris 9 EA install, but I
    can't get it to configure the jumpstart directory
    correctly. Anyone have a step-by-step for doing it?
    Thanks,
    Lucas.

  • Are Dell Poweredge 2900 servers compatible with Oracle VM?

    I am seeking information on installing Oracle VM on a new model dell poweredge 2950 server. The existing hardware is pre-installed with "validated" Virtualization – VMware® ESX software 3.x.
    This pre-installed "validated" Virtualization is partly installed on an SD-Card/USB device attached to the mother board. The existing white paper at DELL does not address this SD-Card/USB configuration [http://www.dell.com/downloads/global/solutions/ovm_ref_config_final.pdf?c=us&cs=04SP10&l=en&s=bsd] . I prefer a response from the Oracle VM team or Dell Employee.
    Edited by: Rajendra on Oct 9, 2008 2:03 PM
    Edited by: Rajendra on Oct 9, 2008 2:03 PM

    I am not sure if Oracle VM server 2.1.2 will install in a Dell PE 2950 but I have installed it on a PE 1950 with no problems. After installation I turrned on VM in the bios and I have been able to install and run a couple of PVMs on it. If the 1950 and 2850 use the same motherboards then it should work for you too.
    However, I have to admit to a concern with this server which may require me to reinstall the OS on it. I have a dual port qlogic HBA installed on it. "Lsmod |grep ql " indicates that the qlogic modules are installed but there are no relevant entries in /proc/scsi. If I boot up the server and use the qlogic firmware, i am able to verify that the card is installed and I am able to get the MAC addresses.
    I have installed VM server on 2850's with older qlogic cards and did not encounter this sort of problem. I am not sure if this is caused by the newer qlogic card, the 1950 Motherboard, or some other factor.
    Unfortunately, this server is physically located 50 miles away from me and I am unable to test out different theories. The first chance I get , I plan to install RH Linux and the usual EMC software on this server, configure it to see LUNS on the SAN then reinstall VM server on it. That should either eliminate a lot of question marks for me or give me some directions to address the issues.

  • All RAM is not  shown by Dell PowerEdge 2650 redhat 4 linux system

    Hi,
    I have Dell™ PowerEdge™ 2650 server having 4 GB ram and i install Redhat 4 linux on it. But in the bios it shows 4 GB and 256 MB ram which i checked physically but in my OS it shows like.
    [root@htss06 ~]# free -m
                       total       used       free     shared    buffers     cached
    Mem:           248        247          1          0          4         59
    -/+ buffers/cache:        182         65
    Swap:          511         10        501It's very strange i am not very good about servers. after googled i found
    re-map the missing
    ram from where your bios hole is located
    but don't know how.
    Thanks
    umesh

    [root@htss06 ~]# cat /boot/grub/grub.conf
    # grub.conf generated by anaconda
    # Note that you do not have to rerun grub after making changes to this file
    # NOTICE: You have a /boot partition. This means that
    # all kernel and initrd paths are relative to /boot/, eg.
    # root (hd0,0)
    # kernel /vmlinuz-version ro root=/dev/VolGroup00/LogVol00
    # initrd /initrd-version.img
    #boot=/dev/sda
    default=1
    timeout=5
    splashimage=(hd0,0)/grub/splash.xpm.gz
    hiddenmenu
    title Red Hat Enterprise Linux AS (2.6.9-5.ELhugemem)
    root (hd0,0)
    kernel /vmlinuz-2.6.9-5.ELhugemem ro root=/dev/VolGroup00/LogVol00 rhgb quiet
    initrd /initrd-2.6.9-5.ELhugemem.img
    title Red Hat Enterprise Linux AS (2.6.9-5.ELsmp)
    root (hd0,0)
    kernel /vmlinuz-2.6.9-5.ELsmp ro root=/dev/VolGroup00/LogVol00 rhgb quiet
    initrd /initrd-2.6.9-5.ELsmp.img
    title Red Hat Enterprise Linux AS-up (2.6.9-5.EL)
    root (hd0,0)
    kernel /vmlinuz-2.6.9-5.EL ro root=/dev/VolGroup00/LogVol00 rhgb quiet
    initrd /initrd-2.6.9-5.EL.img
    [root@htss06 ~]# uname -a
    Linux htss06.htss.com 2.6.9-5.ELhugemem #1 SMP Wed Jan 5 19:38:36 EST 2005 i686 i686 i386 GNU/Linux
    [root@htss06 ~]#

  • Dell Poweredge Server Configurations

    Change from 3 drives to at least 4 and as per Gary D Williams says get out of raid5 (aim for raid10 if you can). Also have no idea about how much storage you actually need, so you might want to calculate your storage requirements using a raid calculator.
    Usually best to add the 2nd cpu on build. Is a pain to add it later.
    Depending upon how many VM's you're adding and if you have other roles you need to run, you may want to bump up your ram a bit (ram is cheap......)

    Hello all,Early morning we received three configurations from Dell for our server updates.Since i'm not so associated with server class hardware, please give advice on this configurations..we are planning to Migrate our Active directory Domain to the R630 and will be installing Vmware Hyper visor on R430.Configuration are as follows.1.Dell PowerEdge R630 Server TECHNICAL SPECIFICATIONS / 27865290
    1 PowerEdge R630 Motherboard1 Intel Xeon E5-2609 v3 1.9GHz,15M Cache,6.40GT/s QPI,No Turbo,NoHT,6C/6T (85W) MaxMem 1600MHz1 Chassis with up to 8, 2.5" Hard Drives, up to 2 PCIe Slots (WithOptional Riser)1 Bezel 8 Drive Chassis1 Riser with up to 1, x8 PCIe Slots + 1, x16 PCIe Slots for x8, 2 PCIeChassis with 1 Processor1 Electronic System Documentation and OpenManage DVD Kit, PowerEdgeR6301 2133MT/s RDIMMs1 Performance Optimized2 8GB RDIMM,...
    This topic first appeared in the Spiceworks Community

  • How to get the drivers for Dell PowerEdge M620 in INF format?

    How to get the drivers for  Dell PowerEdge M620.
    We tried downloading
    http://www.dell.com/support/home/us/en/19/product-support/product/poweredge-m620/drivers but they are in exe?
    How to get inf files for those?

    As Jason pointed out, they can be extracted, I believe this can be done with 7zip also... Or you can just install one M620 from scratch, install the Dell drivers and then use this tool:
    http://gallery.technet.microsoft.com/ConfigMgr-Driver-Injector-aae7d17d to grab the drivers in .inf format.

  • Dell Poweredge 2800 Solaris?

    Hi,
    I have a Dell PowerEdge 2800 server. It has three 73Gig SCSI diska and three 146 Gig SCSI disks.
    This system comes with LSI 53c1030 controllers. The drives are hot plug and the dell backplane has a device that appears on the SCSI bus PE/PV 1 x8 SCSI bp.
    This machine hangs in configuring devices Solaris 10 GA.
    In solaris 9 it sort of works with the Driver from LSI but the I/O rate is limited to 8 Megabytes/ Second (if your lucky, normally running at 1 meg/second). The file systems on the diska have been corrupted three times in 1 day. The messages file has a repeated error message
    ID 3658 kern.info <Default cyl 8921 alt 2 hd 255 sec 63>
    The verify disks in the controller bios takes around 100 minutes for the 73 gig scsi and says its complete at 86%!
    Has anybody got any idea how to get this box working?
    Please Help!

    OK guys,
    I've got it rocking. thanks to the new itmpt driver released by LSIlogic a couple of days ago for download on their site.
    these are the exact steps, how to install Solaris 10 x86 (03/05 release) on a Dell 1850 Dual Xeon 3Ghz, with 2x73GB SCSI disks, using an LSI 1030 controller.
    1. go into the bios in the Dell, and disable the Raid mode, this is done in the Integrated Peripherals, just set the raid card to SCSI enabled. Also, make sure the boot device has the diskette above the hard drive or CD.
    2. download yourself the 119376-01 SD.ITU from sun.
    3. make yourself a DCA diskette (you can get the file called d1_image from the DVD, which you can mount on another pc)
    4. mount that DCA diskette on some linux box, or wincrap box, it is a DOS formatted diskette, and edit the file [solaris/bootenv.rc] file and add a line at the bottom with the following:
    setprop acpi-user-options 0x4
    5. boot the machine with the DCA diskette, and the DVD in the drive (make sure the diskette is booting), and then F4 to add a driver, and add the SD.ITU diskette. Then continue as always (F2....)
    6. When asked what boot option, choose Interactive installation text in CONSOLE MODE (option 4) (believe me, you will need this due to a bug in the graphical install)
    7. continue with the full install, you will notice that even though the e1000g0 is "skipped" on the test, it actually recognizes that you are networked, weird.
    8. at the end of the full install it will ask you to add the SD_11... diskette again, so do that, and press enter. If at this point it complains that it cannot find the sd driver in the diskette, then press enter again, and it will find it (this may or may not occur randomly).
    9. the box will reboot, and the bootup will take a long while doing some SMF stuff (i.e. how to hide inetd so that noone can telnet in any longer hahhaa). During this process, go to the lsilogic.com site, and download yourself the following file: itmpt-x86-5.06.00.zip
    10. unzip that file, and you will notice that it contains itmpt-x86-50600-itu.dd and also itmpt-x86-50600.tar.Z
    the itmpt-x86-50600-itu.dd is an ITU, but it only contains a solaris 9 version of the thing, so it wont be useful at boot time. Ergo, we will use the package file itmpt-x86-50600.tar.Z
    11. Now that you are networked, copy that itmpt-x86-50600.tar.Z file into your dell, and uncompress untar it. Then change into the install folder it creates, and just type pkgadd -d . Go ahead and install the thing.
    12. not it is important that you make sure you do exactly as the installpkg tells you. You need to vi /etc/driver_aliases and comment out the mpt "pci1000,30" and mpt "pci1000,50" lines (i.e. add a # as the first char of the line).
    and UNCOMMENT the ones you will see at the bottom, called itmpt "pci1000,30" and itmpt "pci1000,50"
    in my case the itmpt "pci1000,54" is already uncommented, leave as is.
    13. touch /reconfigure
    14. reboot
    15. PTG.
    The key end effect that was desired:
    - I now get 50-100 megabytes / sec sending data from disk to disk, which is paaaarfect !.
    - Hyperthreading is recognized properly, I can now see 4 cpus,
    - The 8GB of swap I have is recognized.
    In response to Solaris being junk, and moving to Linux or BSD, well, this is not an OS-War thread, but I can guarantee the following premises are true:
    a. the easier to install an OS, the more latent incompatibilities are added to a running system, which invariably manifest themselves at 4 AM, or when you least expect them.
    b. wincrap is not and OS, it's just a bad, sad joke on humanity.
    c. BSD will invariably freeze your whole operation as soon as you have 10 heavy applications accessing the disks heavily for more than a minute.
    d. Linux will invariably need a reboot once in a while, specially when you run more than 5 different heavy apps with lots of ram manipulation, and disk action. (note, if using heavy NFS, then the reboot will be needed once a week or less)
    e. Solaris (sparc or X86) is the only one that allows me to sleep and smile (once it's installed of course), and will not freeze no matter what you throw at it, I have a dual cpu x86 at constant load 3 or 4, doing webserver, database, php runner, and batch image processing, with an uptime of 1200 days.
    cheers to all, wish you luck.

  • Big hard disks in older Dell Poweredge servers

    the 2960 is something like 7 years old so the technology at that stage would be limited as to what it supports.
    To be fair they'll be limits on todays hardware as well. so in 7 years time you'll be asked the same question perhaps ?
    But yes the spec sheet agrees with you 2TB is the max size for a single disk,

    Hi,We've just decommissioned some older servers from our school and my manager is looking to re purpose them into just some spare storage for back ups.We have a Dell Poweredge 2950 which according to Dell's spec has a PERC 6/1 card in it.I'm not terribly knowledgable on RAID cards.According to various google searches that come up, this card doesn't support 2TB disks.We are looking to get a pair of 8Tb disks for this. Is it worth looking to get a better disk controller card for this, or is this not really feasible?I've got two HP Microservers (original N36L and a newer G8, one is getting a 3TB upgrade next week) so maybe one of these might be better for a cheap big storage solution.I'm kind of disappointed that so many enterprise grade servers don't have the means to take rapidly more generous capacity hard disks.
    This topic first appeared in the Spiceworks Community

Maybe you are looking for

  • Qosmio G10-100: Installing second HDD & obtaining mounting bracket

    I'd like to install a second hard drive. Any instructions or general tips on how to do so would be greatly appreciated. I'm looking at purchasing a HITACHI T7K500 Desktar 2.5" - 320 GB Interface: SATA 3.0 GB/s serial & ATA Ultra 133 parallel. Is this

  • Backup from rman coldbackuk

    DB 10.2.0.5 OS Linux I restore the database from a rman cold backup. I am getting the below error while starting the database. SQL> alter database open; alter database open ERROR at line 1: ORA-01589: must use RESETLOGS or NORESETLOGS option for data

  • No eligible version of Logic found in Applications Folder ?

    The Logic Pro 7.1.1 update installs fine on the G4 and G5 macs (running 10.3.9 with RME PCI audio hardware) but on the Powerbooks (667 DVI, running 10.4.1, no ext audio hardware) it refuses to install. The installer does open and for a splitsecond so

  • Help me PLEASE, I am stuck!!!!

    Hi everybody and happy new year to all of you. I do not know if this is the right forum for this post, if not please let me know!! I am asking for your help because I am really not getting anywhere with my project. So you guys are my last hope. I am

  • Photoshop Filter like paper currency/Wall Street Journal author pic?

    WSJ articles often have the article author's image in a small box. It's a B/W line drawing style reminiscent of images on paper currency. It there a photoshop filter that can produce similar images from photos of people? Thanks