Hi
My scenario is JMS -> XI -> MAIL
every message of the JMS should b collected into 1 mail
I have devloped my BPM according to the Collect pattern in SAP BASIS
my problem is that the messages of the BPM are stucked in the outbound queue with a green flag!
even tought the queue is registed,and no messages r there
so the bpm is trigged but some how get stucked
did some1 experinced the same issue
Thx,Shai

Ok
now i solved the green flag issue
the user WS-Batch was locked  ( dont use CUA in your project )
now my bpm falied at mapping
my secnarion is N..1 Messages
so I have 2 mapping programs , 1 adds dummy corrlation to each message which is 000 and the other 1 is doing the N..1 adding
my problem is that the XML required for both is Diffrent!!
because when u use multi mapping it add more elements ( Messages and Message1 )
any1 have idea how to solve that issue?

Similar Messages

  • BPM Collect Scenario errors at transform stage

    The BPM Collect scenario is using a Fork within a Block.
    Branch 1 - Loop Receive Append Container Endloop
    Branch 2 - Receive step of triggerIdoc
    End of Block
    Transform step - multiline container of XML documents to one XML document
    Send step
    BPM Errors at Transform step with JCo mapping not available.
    Whilst BPM in Error (Workflow in Error) more messages being received but never processed as the RECEIVE event is "lost" for these messages.
    We are looking at redesigning the BPM to reduce the likelihood of this transform error.
    In the meantime was looking at ways to Alert the administrator straight away to the error. As we have a workaround to get the process going and to pick up the stranded messages. So have started setting up the ALERT categories as described in How to Guide, for Adapter and Interface. Will this work?
    Also in the Transform step there is a box (system exception) but I can't enter anything in. Is there a way to do this if the Alert category doesn't report an error in the BPM. OR do I have to add the Transform step into a Block of its own?
    Advice gratefully received if we come up with a working solution will post it out here. Have spent a large amount of time reading posts and blogs on here but have not got a clear picture yet of what is best to do.
    thanks,

    > Whilst BPM in Error (Workflow in Error) more messages
    > being received but never processed as the RECEIVE
    > event is "lost" for these messages.
    This should give you an issue called Parked Messages. The best way to deal with this is to actually define a Local Correlation. In the Block Step properties, you will have an option, Use Correlation --> Give the name of the Correlation . This will make sure that when there is an error, the Correlation become inactiva and a new BPM instance is created.
    > In the meantime was looking at ways to Alert the
    > administrator straight away to the error. As we have
    > a workaround to get the process going and to pick up
    > the stranded messages. So have started setting up the
    > ALERT categories as described in How to Guide, for
    > Adapter and Interface. Will this work?
    Not sure if this will work. The issue is that the messages are passed to the IE already and will be in wait step waiting for an active BPM 's receive step How will another interface pick up this message?
    > Also in the Transform step there is a box (system
    > exception) but I can't enter anything in. Is there a
    > way to do this if the Alert category doesn't report
    > an error in the BPM. OR do I have to add the
    > Transform step into a Block of its own?
    This is what is called exception handler. Defined a Exception handler for the Block. Right Click block, insert Exception Branch, give name of the Hanler and then you can select this in the Transformation Step's System Error. This is like Try - Catch of Java.
    Regards
    Bhavesh

  • BPM collect messages error

    Hi
    we are experiencing problems in BPM Collect pattern, error is not clear.
    Our payload before input to BPM
    <record>
    <row>
    <key>1</key>
    <val1>1</val1>
    </row>
    <row>
    <key>1</key>
    <val1>1</val1>
    </row>
    </record>
    this is given to BPM, and BPM is following exact collect pattern in SAP Documentation like
    1. Block with restricted by correlation (/record:key1), deadline with 1 minute, used by correlation
    2. within Block, unlimited loop, with started recieve step, activated correlation, and append records with container operation
    3. multi-mapping transform step, with multiple records to single record and followed by send step.
    we are getting error in the blok step, no description of error.
    BPM is activated without any errors
    Please advise, appreciate all ur help.

    Any body got the solution for this . I am having same problem .
    My Payload as follows
      <?xml version="1.0" encoding="UTF-8" ?>
    - <ns0:BpmPatternCollectMessageToBeCollected xmlns:ns0="http://sap.com/xi/XI/System/Patterns">
      <ID>1</ID>
      <OverallNumber>1</OverallNumber>
      </ns0:BpmPatternCollectMessageToBeCollected>
    for BPMPattrenCollectTime BPM and I amhaving error on outbound side in BPE
    when I dig into technical details The BPM details as follows
    Error during result processing of work item for Reciving Message Step
    Regards
    Murali

  • BPM Collect pattern is not coming out  and it is in loop.

    Hi Experts,
    We have implemented a BPM Collect Time pattern and it was working fine in Dev and QA environments perfectly. Couple of days back we have some server issue in Dev environment and Basis team has done some thing with File Storage. From that time, all our BPM's were not working in Dev. It is showing that the block is waiting for some event to trigger and it is in Process state.  We have set it for 5 min and block is not coming out from loop.   We exported the code to QA and it is working in QA.  We tried SWU3 transaction as given in the below forum and it didn't help us.
    bpm collect time infinite loop error
    Some one please help us.
    Thanks
    Venkat
    Edited by: Venkata Gupta on Nov 27, 2008 12:54 AM

    Hi
    Is Your BPM having deadline branch ?
    If there is any system Exception then catch it.
    http://help.sap.com/saphelp_nw04/helpdata/en/33/4a773f12f14a18e10000000a114084/content.htm.
    According to thread mentioned by you ,Schedule your Missed Deadline Branch.
    Also check your BPM using transaction SXMB_MONI_BPE and find out which step have error.

  • BPM Collect Transformation Step Raise Alert need help

    Hi,
    Scenario BPM Collect.
    Block 1 - Multiple xml messages received and collected into multiline container.
    Block 2 - Transform multiline container element into single message. Mapping Error throw Transformation Exception.
    Block 2:Exception Branch - Transform multiline container element to error multiline container element (based on BpmPatternReqRespTimeOut with a twist).
    Block 2:Exception Branch - Send multiline container element to Communication Channel for further error analysis.
    Block 2:Exception Branch - Throw Alert BPM_ALERT Transformation Failure message.
    Getting Compilation errors because I am not allowed to output a multiline container element...?
    Behaviour without the Exception Branch Transform and Send is that the first message collected in the ccBPM goes to Green Flag and the others goto chequered flag when the BPM_ALERT is thrown. This is not desirable behaviour.
    Would like to output multiple line container element so I easily know which group of messages failed ie file 1,2,3... so that I can go to the Error folder and repost them in the Sender Communication Channel if required.
    Once this is working I am trying to identify which file had the conversion problem so I can filter if out from the others and process the others attempting to pass information from a UDF as to which item in the multiline container element I reached before I had a problem int he original mapping...?
    I have read Michal Krawcyzk's blog on ALERT variables and Help on Throwing Alerts etc but I am progressing slowly with my solution...
    thanks,
    V

    Thankyou Chirag for those Blogs.
    The first is the one I have looked at most recently and the second has given me an idea.
    If I change my mapping of the multiline container element each line holds an xml message to the error element by calling a UDF to map the payload across then at least I would have output my Payload that errored? I will try it and see Java coding is not my forte currently.
    thanks,
    V

  • BPM Collect Message dependent AND time dependent

    Hi
    I have a IDOC to file scenario where I have to collect all the IDOC until I receive a stop IDOC.
    Once the End collect IDOC is received I have to do a n:1 transformation and write the file to the FTP.
    The problem is, at times the IDOC which is suppose to end the collect loop gets stuck in ECC R3 system.
    So Im wondering If I can do something like say, we have two options inside BPM both time dependent and message dependent.
    In this case which ever comes first (the Stop/END IDOC or the Time say 3 mins) will end the collect process.
    Can anyone pls suggest will it work and if so what are the additional steps I have to introduce in the BPM.
    Pls advice.
    Right Now these are the steps in the BPM Collect Message dependent.
    1. Block (I have used correlation)
    2. Fork inside the block
    3. Fork branch one has a look with end condition as 1=1; then a receive step and a container operation inside the loop.
    4. Fork branch two receives the end collect idoc.
    5. Transform step outside the block.
    6. Send step.
    Thanks
    Prasanna

    Hi Abhishek/ Raj
    Thanks!!
    I have done the changes let me confirm after testing it once. In the mean time I have one more question regarding the same BPM, as I have mentioned in the first post, the BPM contains the 6 steps mentioned but the the 6th step is inside another block (Block2).
    The steps 1 to 4 are inside Block1.
    The step 5 ie the transformation step (n:1) is in between the Blocks ie not inside any block (hope im not confusing).
    The second block is for sending the file to the FTP and based on the acknowledgement (transport level) I have to send an email.
    So Block2 already contains a deadline branch, it is to wait for the positive acknowledgement for say 3 mins and send the error email if incase we dont get positive ack within the time limit.
    My doubt is,
    1. Is it the only way (having two block and two wait steps) to achieve this.
        (one block for collecting and one block for ack)
    2. Is there any way I can have a single Block in the BPM insted of two. If so what are the steps.
        Having single block, Will improve anything??
    Thanks
    Prasanna

  • The Cube with ID = Rate doesn't exist in the collection Error Message

    When doing a Full Optimization in the Rate cube I get a "The Cube with ID = Rate doesn't exist in the collection" error message. What is causing this error and how do I fix it?

    I have seen this error when reporting services was not properly configured. can you connect to http://servername/reports ?
    If not try to fix reporting services first, this solved the problem for me in the past.
    But usually in this case all the aplications are giving this error when modifying. Is this also the case in your appset?
    Does Apshell work when you modify the application there?
    -Joost

  • BPM for error handling and acknowledgements

    Hi,
    Can any one tell me how to handle BPM for error handling and acknowledgements in one scenario.
    Please send me the link if you have other wise give me the solution on the same.
    Thanks,
    Nagesh

    Hi !
    Just check out these links This might help you.
    Usually Application Level Acknowledgement is considered during Sync communication. If you are using RFC, you can make use of Sync communication. So you can handle it without bpm, provided your both sender and receiver are sync interfaces.
    To know about Ack-
    http://help.sap.com/saphelp_nw2004s/helpdata/en/f4/8620c6b58c422c960c53f3ed71b432/content.htm
    you can not dirrectly access the content of the ACK, however the BPM shows different behaviours based on the ACK status. E.g. if the ACK contains a success message the BPM will continue in its normal process, if the ACK contains a permanent error, it will either stop or go through an exception branch (provided such a branch has been defined). Have a look at the documentation: http://help.sap.com/saphelp_nw04/helpdata/en/43/65ce41ae343e2be10000000a1553f6/content.htm It doesnt"t state the above mentioned behaviour in detail but says that you need to define an exception branch.
    The trickiest part is always to find out, when you will get a transient vs. as permanent error ack. If you are using ACKs with Proxies refer also to this link http://help.sap.com/saphelp_nw04/helpdata/en/29/345d3b7c32a527e10000000a114084/content.htm and this http://help.sap.com/saphelp_nw04/helpdata/en/f4/8620c6b58c422c960c53f3ed71b432/content.htm
    http://help.sap.com/saphelp_nw04/helpdata/en/29/345d3b7c32a527e10000000a114084/content.htm
    http://help.sap.com/saphelp_nw04/helpdata/en/7b/94553b4d53273de10000000a114084/content.htm
    <b>The following link has entire configuration of Receiver XI Adapter (including acknowledgements)</b>
    http://help.sap.com/saphelp_nw04/helpdata/en/f4/0a1640a991c742e10000000a1550b0/content.htm
           <b>   eror handling in BPM.  
    </b>
    1. CCMS monitoring
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/42fb24ff-0a01-0010-d48d-ed27a70205a8
    2. BPM Monitoring
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/e7bc3a5a-0501-0010-1095-eb47159e169c
    3. Monitoring XML Messages http://help.sap.com/saphelp_nw04/helpdata/en/41/b715045ffc11d5b3ea0050da403d6a/frameset.htm
    /people/sap.user72/blog/2005/11/29/xi-how-to-re-process-failed-xi-messages-automatically
    monitoring BPm https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/e7bc3a5a-0501-0010-1095-eb47159e169c
    Reconciliation of Messages in BPM - /people/krishna.moorthyp/blog/2006/04/08/reconciliation-of-messages-in-bpm
    Also see the below BPM related links
    check list for BPM https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/3bf550d4-0201-0010-b2ae-8569d193124e
    /people/shabarish.vijayakumar/blog/2005/08/03/xpath-to-show-the-path-multiple-receivers
    http://help.sap.com/saphelp_nw04/helpdata/en/3c/831620a4f1044dba38b370f77835cc/content.htm
    http://help.sap.com/saphelp_nw04/helpdata/en/62/dcef46dae42142911c8f14ca7a7c39/content.htm
    http://help.sap.com/saphelp_nw04/helpdata/en/de/766840bf0cbf49e10000000a1550b0/content.htm
    http://help.sap.com/saphelp_nw04/helpdata/en/cb/15163ff8519a06e10000000a114084/content.htm
    http://help.sap.com/saphelp_nw04/helpdata/en/08/16163ff8519a06e10000000a114084/content.htm
    Many other examples can be found under the following link at help.sap.com
    http://help.sap.com/saphelp_nw04/helpdata/en/14/80243b4a66ae0ce10000000a11402f/frameset.htm
    And some weblogs
    https://weblogs.sdn.sap.com/pub/wlg/1403 [original link is broken] [original link is broken] [original link is broken]
    /people/siva.maranani/blog/2005/05/22/schedule-your-bpm *****
    /people/krishna.moorthyp/blog/2005/06/09/walkthrough-with-bpm
    /people/michal.krawczyk2/blog/2005/06/11/xi-how-to-retrieve-messageid-from-a-bpm
    /people/arpit.seth/blog/2005/06/27/rfc-scenario-using-bpm--starter-kit
    /people/sravya.talanki2/blog/2005/08/24/do-you-like-to-understand-147correlation148-in-xi
    /people/michal.krawczyk2/blog/2005/09/04/xi-do-you-realy-enjoy-clicking-and-waiting-while-tracing-bpm-steps *****
    /people/udo.martens/blog/2005/09/30/one-logical-system-name-for-serveral-bpm-acknowledgements *****
    /people/sudharshan.aravamudan/blog/2005/12/01/illustration-of-multi-mapping-and-message-split-using-bpm-in-sap-exchange-infrastructure
    /people/kannan.kailas/blog/2005/12/07/posting-multiple-idocs-with-acknowledgement
    Also have a look at these seminars,
    https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/media/uuid/daea5871-0701-0010-12aa-c3a0c6d54e02
    https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/media/uuid/e8515171-0701-0010-be98-e37bec4706cc
    Thanks !!!
    Regards
    Abhishek Agrahari
    Questions are welcome here!!
    <b>Also mark helpful answers by rewarding points</b>

  • BPM: Permanent error in BPE inbound processing

    Hi guys...
    i am having a problem in my scenario which is involving BPM.
    The problem is when i execute the interface it is showing green flag aginst PE in sxmb_moni and in smq2 one queue is showing with sysfail and BPM: Permanent error in BPE inbound processing  error.
    yes..i searched on SDN and found resources like Note number 1126656
    i checked al the steps which were earlier mentioned posts like:
    SWWL:  there are no entries existing
    SMQ2: cleared the queues ,regenerated but still no luck.
    My undertsanding is no work is being generated at all .
    I checked BPM with F7 : its correct no errors
    BPM has return code of 0 in sxi_cache
    In ID BPM is latest and refreshed.
    Is there any way i can overcome this problem.
    Your inputs will be of real help.
    Thanks in advance.
    Regards,
    Kiran.

    My undertsanding is no work is being generated at all .
    If you are getting the error for Source ---> BPM  flow then there is a possibility that the ID objects (RD, Interface determination) are to be blamed.
    1) Recreate these particular ID objects/ make some dummy changes
    2) Activate and ensure that Cache is refreshed
    3) Delete the entry in the queue (or delete the queue)....do this only if the XI system is not of Quality, production
    4) some times the BPM cannot be triggered from sending a test message from RWB .... so make a testing from the source application .... this particular case has heppened to me and hence suggesting to you.
    Regards,
    Abhishek.

  • BPM Collect Pattern Scenario :Container is empty for the loop at run time

    Hi Friends,
    I am working on BPM Collect Pattern Scenario after looking into the example delivered by SAP in namespace http://sap.com/xi/XI/System/Patterns and IP name as BpmPatternCollectPayload.
    After configuring the same and when it is run, I see strange behaviour as illustrated below
    1. Container step is empty and not able to see the counter for which it needs to be incremented at runtime
    2. I understand that Loop should start and it need to be incremented as when we get a new message into the same BPM.
    But I observe that it is creating a new message and loop never stops and completes the condition and comes out to go to next step.
    Request your help.
    Regards,
    Hussain

    Hi,
    define or declare a variable with name counter and type as integer in Container where you define abstarct variables...
    Thanks,
    Madhu

  • BPM Collect Pattern:File to IDoc

    Hi,
    My scenario is File to Idoc. An invoice excel file will be sent by the vendor.The excel has a built in macro, which converts the excel to a csv file and file is placed in a file share server.
    *Logic of Macro: *
    There will be a button in the excel file containing macro. In one excel file there would be multiple invoices that contains different number of item lines, The macro checks the u2018Invoice Numberu2019, lines with the same invoice number will be saved in one CSV file. So for example a excel file contains 5 invoices, when press the button that contains the macro, there will be 5 CSV files created under the same path, each CSV file contains one invoiceu2019s information.
      After this I have to post the Inovices in to SAP using an IDoc.
    So, I am using BPM collect pattern to achieve this. In the collect pattern,  I see a correlation defined on one of the source fields,  What does correlation exaclty do in my  case. Let's say I have defined a correlation on Source field called Invoice number.
    BTW I am using FCC on the filed adapter to change the CSV(Invoice) to xml
    Thanks,
    Kiran

    Hi
    to use Xpath for your receiver det. ref these blogs;
    a combination of logics should help you in this case ...
    Customise your 'XPATH' Expressions in Receiver Determination
    XPath to show the path (Multiple Receivers)
    File to Multiple IDocs (XSLT Mapping)
    Try removing BPM from ur scenario.
    1:n could be achieved without BPM
    Various multi-mappings and Optimizing their Implementation in Integration Processes (BPM) in XI.
    Regards,
    Suryanarayana

  • BPM collect pattern based on payload

    Hi,
    i am doing BPM Collect pattern based on stop message which is RFC. Means, i need to collect the IDOCs until i get the RFC from another system.
    For this i am using predefined pattern BPMcolllect pattern which is in BASIS SWCV.
    is it possible to do with out correlation?
    if correlation is required, there should be one common fiield between two messages?
    Thanks,
    karthik

    Hi ,
    Your design it self wrong, when you develop interface as a sender IDoc , then how come you will receive RFC in to BPM??
    so check your requirement with your client, if you want to collect messages there are different ways, implementing patterns in last option.
    search in sdn.
    Regards,
    Raj

  • IDoc to Soap, with BPM - Permanent error in BPE inbound processing

    Hi Experts,
    IDoc to Soap, with BPM - > Permanent error in BPE inbound processing
    How to rectify this any issue???
    Thanks-
    sk

    Hi,
    The inbound processing encountered a permanent error and the queue therefore stopped.
    The error message "Permanent error in BPE inbound processing" may be caused by the following:
    - At the start or when you process a process instance, the inbound processing encounters an exception that was not handled. This exception is triggered, for example, by a transformation step, a synchronous send step or a control step but it was not caught in an exception handler branch. If the exception that was not handled occurs in the first transaction of the started process instance, the system does not write the process instance to the database but it sets the queue that has this error message to the error status.
    Refer to the help in Note 1082099
    - The inbound processing triggers this error if the correlation evaluation shows that a message should be delivered to a process instance that has the status "error". Since delivery to process instances that contain errors is not permitted, the queue is stopped.
    Use the simulation of the message delivery in the detail view of the relevant queue LUW to determine the relevant process instance for the affected message and use transaction SXMB_MONI_BPE "Continue Process Following Error" (or transaction SWF_XI_SWPR) to continue. If you cannot continue the process instance, check whether you can logically delete the instance. In this case, use the method that is described in Note 807906 to logically delete a process instance.
    Check whether your system contains other process instances that have errors in order to detect similar problems. Use transaction SXMB_MONI_BPE "Continue Process Following Error" or transaction SWF_XI_SWPR.
    Use the report RSWF_CRL_MAINTAIN to check all of the correlation instances in question or the relevant process instances that you can reach using "Display Work Item".
    - Messages that cannot be delivered because no correlation instance can be found may lead to the error that is mentioned here. Check whether the causes that are outlined in Note 1094028 affect your case.
    Hope this will help you.
    Regards
    Aashish Sinha
    PS : reward points if helpful.

  • Grid Control EMC Clariion Metric Collection Error

    Hi,
    I just deployed the EMC Clariion plugin and I get a metric collection error:
    Storage Processor Configuration Collection Failure
    Can't call method "che_freemem" on un undefined value at /<agent_path/sysman/admin/scripts/emx/emc_clariion_storage/emc_clariion_processor.pl line 127.
    Anyone got any idea?
    Cheers,
    Olivier

    It could be a parsing error due to unstrucured format of the navicli out put.
    other metrics and reports should work fine.
    Not a consistent error . Not seen on other deployments.

  • Microsoft SQL Server Metric Collection Errors

    Hi
    I've installed the Microsoft SQL Server plugin.
    I've added a SQL server for monitoring.
    It only monitors / picks up Cache Hit Ratio.
    Then i'm getting the following Metric Collection Errors:
    Database Oct 31, 2006 2:35:45 PM Collection Failure Missing Properties : [pro...
    [b]SQL Server Process Oct 31, 2006 2:35:45 PM Collection Failure Missing Properties : [pro...
    [b]Processor Oct 31, 2006 2:35:45 PM Collection Failure /u/oracle10/OracleHomes/a...
    Error Log Entry Oct 31, 2006 2:31:32 PM Collection Failure Missing Properties : [pro...
    [b]MSSQL DatabaseFile Oct 31, 2006 2:31:32 PM Collection Failure Missing Properties : [pro...
    [b]SQL Server Role Oct 31, 2006 2:31:32 PM Collection Failure Missing Properties : [pro...
    [b]MSSQL Transaction Log Oct 31, 2006 2:31:32 PM Collection Failure Missing Properties : [pro...
    [b]Database Parameter Oct 31, 2006 2:29:10 PM Collection Failure Missing Properties : [pro...
    User Oct 31, 2006 2:29:10 PM Collection Failure Missing Properties : [pro...
    [b]Integrated Security Setting Oct 31, 2006 2:29:10 PM Collection Failure Missing Properties : [pro...
    [b]MSSQL FileGroup Oct 31, 2006 2:27:10 PM Collection Failure Missing Properties : [pro...
    Login Oct 31, 2006 2:25:14 PM Collection Failure Missing Properties : [pro...
    [b]Registry Setting Oct 31, 2006 2:24:21 PM Collection Failure Missing Properties : [pro...
    [b]SQL Server Oct 31, 2006 2:24:21 PM Collection Failure Missing Properties : [pro...
    [b]Database Setting Oct 31, 2006 2:24:21 PM Collection Failure Missing Properties : [pro...
    Target  <servername>.local
    Type  Microsoft SQL Server
    Metric  Database
    Collection Timestamp  Oct 31, 2006 2:35:45 PM
    Error Type  Collection Failure
    Message  [b]Missing Properties : [provided_host_os]
    Thnx,
    Kenneth

    Not sure if you got the plug-in working. If not, read on...
    The error is due to failure in internal computation of the SQL Server Host related information.
    Ensure that
    1. All pre-requisites (specified in SQL Server plug-in Installation Guide) are satisfied
    2. Provided property values for discovery of the SQL Server target are correct
    - JDBC URL has correct port number
    - If you are using older version of SQL Server plug-in, the name of SQL Server
    instance that you provided is correct

Maybe you are looking for

  • Updating the pa2006

    Hi Expert, I have to update the one field of the IT2006 record of a particular personal no. Each pernr has a two records in the table. I have to update the record with subty field value =50. so when I am using loop at it_pa2006 ( which is of type it2

  • It it possible to create chat, small games in Project Siena ?

    It 

  • Mac Mini Background changes at boot

    I'm helping a friend with her mac mini and every time she reboots it resets the background image to the Yosemite default.  She's done all the updates and she only has 1 desktop running in Mission Control.  I have tried creating a second desktop, chan

  • Wireless Point to Point Cisco 1242ag

    Hi Is it possible to set up some sort of authentication where the root bridge and non-root bridge only associate with the opposites MAC address?

  • New iTunes slower?

    OK, so maybe it's just me, but does anyone else think the new version of iTunes is reaaallly slow when importing music (from a CD for instance) and downloading movies or shows? It took about 40 minutes to downloand a Law and Order episode the other d