[BUG] Agilent ESA PSA Series LabVIEW driver for Models E4401B and E4402B

Agilent ESA PSA Series LabVIEW driver are not working with Models E4401B and E4402B.
Driver Version 2.1.1
LabVIEW: 2009
Web Link: http://sine.ni.com/apps/utf8/niid_web_display.download_page?p_id_guid=309EBE8FF8BC0E76E0440003BA7CCD...
Problem: ID Query in "Agilent ESA PSA Series.lvlib:Initialize.vi". ID Answer from Instrument is not match with strings in Match Array. Somebody left whitespace at the strings end. ("Hewlett-Packard,\sE4401B\s" and "Hewlett-Packard,\sE4402B\s").
Everything else is working well.

Hi JCC,
Thanks for bringing this to our attention, a Corrective Action Request has been created: CAR - Corrective Action Request - #247239 and a member of R&D will take a look into this to get the issue resolved.
Kind Regards,
Applications Engineer

Similar Messages

  • Agilent ESA PSA configure acqusition vi error

    I tried using the ESA PSA driver with LabVIEW 8.0
    First I tried the configure vi to see that I am talking to the instrument, this works fine.
    Then I tried the example "Agilent ESA PSA Series Acquire trance.vi" and got an error -113 undefined header.
    Does someone have any idea what might cause this error?
    Ori Idan

    Tanya I am glad you responded. I tried to work some changes to the driver last year and I was not able to find a responsible party (i.e. National or Agilent).to work the recommendations I have into the driver to fix the issues. I'd like to work with you to make a number of recommendations in terms of fixing some shortfalls in the driver and also change the command grouping that is current. The Undefined Header error is being thrown due to inappropiate command grouping and doing commands not appropiate for the state the instrument is in. I have worked extensively with the PSA and ESA not only in Spectrum Analyzer mode, but have also worked in the Modulation Measure mode and can make a significant number of suggestions to improve. Please feel free to contact me offline at my email [email protected] (personal) or [email protected] (work) so we can follow thru on the suggestions. Thanks for replying on this and I look forward to working with you to address these issues and making a better driver. We have been considering rewriting this driver to fix the issues, but having National work it, keeping ownership and keeping the updates in the public domain is prefered. If you prefer to call my cell number is in the National database.

  • Is there any LabVIEW driver for the Agilent 53147A counter/power meter?

    I am trying to find a LabVIEW driver for the Agilent 53147A counter/power meter, but I cannot find it. Is there any?

    NI does not have a driver and a quick check with Agilent shows that they don't have a driver either.
    You can go to http://www.ni.com/devzone/idnet/ and request a driver. You will also find links on how to create your own driver. Your other option is to use the Instrument I/O Assistant.
    p.s. In the future, you should use the Instrument control board for posting questions. this board is for NI counter/timer products.

  • Looking for LabVIEW driver for Agilent (HP) 4349B High Resistance Meter

    I've been looking for a LabVIEW driver for Agilent (HP) 4349B High Resistance Meter.
    Does anyone have one?
    Thanks,
    Avner

    Hello,
    It looks like you'll get a reply by Friday; if not repost and I'll follow up for you
    Thank you,
    JLS
    Best,
    JLS
    Sixclear

  • Where can i find a Labview driver for the "8990a PEAK POWER ANALYZER" it's not on NI's site.

    where can i find a Labview driver for the "8990a PEAK POWER ANALYZER" it's not on NI's site.
    if there is no driver maybe you can tell me the closest instrument that comes to this one from the list at,
    http://search.ni.com/query.html?lk=1&col=alldocs&nh=500&rf=3&ql=&pw=595&qp=%2BContentType%3AInstrumentDriver+%2BIDNetManufacturer%3A%22Hewlett-Packard%22&qt=peak+power+analyzer&layout=IDNet
    so i could modify and use the driver

    Hello,
    It looks like Agilent/HP makes the 8990A, but I was not able to find a driver for it that we or Agilent has written for this device.
    Since I am not familiar with the 8990A, I cannot recommend which drivers might be similar, but you are pointed in the right direction. Agilent themselves might know more about which models use similar command sets so that you can modify a driver easily.
    Hope this helps.
    Scott B.
    Applications Engineer
    National Instruments

  • HP laserjet 1200 series pcl5 driver for windows 7 64bit and windows 8.1 64bit

    Dear
    I need
    HP laserjet 1200 series pcl5 driver for windows 7 64bit and windows 8.1 64bit
    can anyone provide me ? no links to read text, direct solution is welcomed
    thanks in all

    Hi.
    You may download the Universal Print Driver PCL5 below, it is compatible with both Windows 7 or 8 64-bit.
    For USB select Plug n Play, for network select Tradiotional Mode and follow the steps by setting a TCP/IP Port with the IP Address of the printer:
    http://h20566.www2.hp.com/portal/site/hpsc/template.PAGE/public/psi/swdDetails/?sp4ts.oid=29790&spf_...
    Please let me know of any issuesm
    Shlomi
    Say thanks by clicking the Kudos thumb up in the post.
    If my post resolve your problem please mark it as an Accepted Solution

  • RS232 Labview driver for SR830 lockin Amplifier

    Hi,
    I want to install Labview driver for Stanford Research SR830 lockin amplifier for RS232 port. NI has drivers for GPIB but I could not find any for RS 232 comm port.
    Please let me know how can I find driver for RS232 port.
    Regards,
    Nitin

    Dear Jason S,
    I also want to communicate with sr 830 with the RS232 interface. You said I had to rewrite the whole thing. What does that really mean? Rewrite the driver? If so, what language will it be?
    JasonS' wrote:
    Hello Nitshu-
    As you mentioned, this driver only supports GPIB, and not RS-232.  This driver was originally created in 1994, so it was not created using VISA.  This means that to convert this driver you would need to essentially rewrite the entire thing.  There are not currently any plans to update this driver to support RS-232, but you could easily communicate with it by adding a GPIB Interface to your system.
    Let us know if you have any specific questions we can help answer.
    Jason S.
    Applications Engineer
    National Instruments
    Thank you for answering my question

  • Labview driver for HP 8560 EC Spectrum Analyzer

    I'd appreciate it very much if somebody help to find
    Labview driver for HP 8560 EC Spectrum Analyzer using GPIB.

    Unfortunately I was unable to find a driver for this instrument either. This leaves you with one of a couple options. First, I would like you to submit a request for this driver at:
    http://zone.ni.com/idnet/other.htm
    We develop drivers based on demand and popularity so the more requests we have for it, the greater the possibility that we will develop one.
    If you would like to try developing your own instrument driver (or modify the existing one), we have documentation, model instrument drivers, and driver templates to help at :
    http://zone.ni.com/idnet/development.htm
    We also have a syndicate of third party vendors that specialize in National Instruments' products and services. Some of the vendors specialize in driver development. I would sugg
    est contacting one of the Alliance members at:
    http://www.ni.com/alliance
    Good Luck.
    Kim L.
    Applications Engineer
    National Instruments

  • Looking for LabView driver for Suruga-Seiki motorized stage controller model D70

    I'm Looking for LabView driver for Suruga-Seiki (Japan)motorized stage controller model D70, GPIB or RS232 (optional model D92).

    Hi,
    Unfortunately, I was unable to locate a driver for your instrument. I would like you to submit a request for this driver at: http://zone.ni.com/idnet97.nsf/instrumentdriverrequest/ and with the instrument manufacturer. We develop drivers based on demand and popularity so the more requests we have for it, the greater the possibility that we will develop one.
    If you would like to try developing your own instrument driver (or modify the existing one), we have documentation, model instrument drivers, and driver templates to help at :
    http://www.ni.com/devzone/idnet/development.htm
    We also have a syndicate of third party vendors that specialize in National Instruments' products and services. Some of the vendors specialize in driver development. I would s
    uggest contacting one of the Alliance members at:
    http://www.ni.com/alliance
    An instrument driver is a collection of functions that implement the commands necessary to perform the instrument�s operations. In short, someone read the instrument user manual and implemented some of the functionality in a program for the end user. Instrument drivers are not necessary to use your instrument. They are merely time savers to help you develop your project so you do not need to study the manual before writing a program.
    There are example VI's in LV on Instrument Connectivity. If you go to the Help menu >> Examples.. >> I/O, you will see a couple and Examples.. >> Fundamentals for File and String manipulation. I would suggest tweaking them to suit your application. Also the specific command that your instrument responds to can be found from it's manual.
    Some useful resources for your application are
    ni.com > NI Developer Zone > Development Library > Instrument Connectivity
    http:/
    /search.ni.com/?col=alldocs&layout=TechResources&ql=a , to search examples and knowledge bases
    Hope this helps!
    Best Regards,
    Aaron K.
    Application Engineer
    National Instruments

  • How to build a Labview driver for a USB device?

    I have purchased a USB Hall probe (a device that measures magnetic fields) and now I need to build a LabVIEW driver for it (the company that sells this device did not build drivers for it, to keep the price down I suppose). The USB device does come with an operating software, but what I need is to control the device using LabVIEW. I have some experience with LabVIEW, but none with building drivers. I don´t really know where to start, so any advice would be helpful.

    To do USB in LabVIEW you'll want to get the NI-VISA driver. After you've got VISA, check out a few examples: 
    USB Instrument Control Tutorial
    Six Things You Need to Know about USB Instrument Control
    There are also examples built in to LabVIEW (under Help>>Find Examples to open the NI Example Finder, then under Hardware Input and Output>>VISA)
    Tim W.
    Applications Engineering
    National Instruments
    http://www.ni.com/support 

  • Driver Intel USB 3.0 Driver for Intel 8 and U/Y Series doesn't work with a specific Kingston USB

    Hello guys, just the other problem I'm facing with the 840 G2
    I'm working in the MDT image for the HP 840 G2 and I would like to comment you one problem that I found with the USB 3.0 drivers. Based in your webpage, the last HP USB 3.0 official drivers are:
    Intel USB 3.0 Driver for Intel 8 and U/Y Series Products
    3.0.1.41 A from 15 dic 2014
    I have found that those drivers doesn't work properly; if you insert a Kingston DTSE9 (32GB) the content of the usb will not be accessible randomly. The event viewer will display:
    The driver detected a controller error on \device\harddisk1\DR13
    To solve this problem you have to obtain the last version of the drivers from the Intel webpage:
    https://downloadcenter.intel.com/download/22824/USB-3-0-Driver-Intel-USB-3-0-eXtensible-Host-Control...
    I have all the drivers properly installed and it seems that the computer is working fine, however I'm a little worry thinking if I should update all the driver to avoid possible problem like this one.
    If you have found similar problems it would be nice to share it.
    Thank you very much.

    Hi,
    Please use the following post:
        http://h30434.www3.hp.com/t5/forums/replypage/board-id/General/message-id/76373
    Thanks.
    BH
    **Click the KUDOS thumb up on the left to say 'Thanks'**
    Make it easier for other people to find solutions by marking a Reply 'Accept as Solution' if it solves your problem.

  • Does anybody already developed or knows where can I find a LabVIEW driver for a CETA 800 equipment?

    Ronaldo Schwarz
    Selco Sistemas Eletronicos Ltda

    Ronaldo,
    I just did a search of the web (and of NI resources), and I could not find any helpful pages offering information on LabVIEW drivers for this CETA 800 equipment.
    The only suggestion I have is that perhaps the manufacturer of the device may have a driver, or may perhaps know of someone who does provide one.
    I hope you are able to find a LabVIEW driver for this instrument. If you end up having to write one of your own, you can visit www.ni.com/idnet to find several resources on writing your own instrument drivers.
    Have a pleasant day.
    Sincerely,
    Darren Nattinger
    Applications Engineer
    National Instruments
    Darren Nattinger, CLA
    LabVIEW Artisan and Nugget Penman

  • LabVIEW driver for a ControlTechniques motor controller

    Anyone know of LabVIEW driver for a ControlTechniques
    Unidrive motor controller?
    Or any info/pointers to programming them via LabVIEW?
    Any help much appreciated
    Paul
    Dr Paul Rocca - Managing Director
    Brill Engineering Ltd, 3 Longwood Court,
    Love Lane, Cirencester, Gloucestershire
    GL7 1YG. www.brill-eng.co.uk
    Phone: 01285 883888 Fax: 01285 883876
    NI Alliance Member Since 1992
    Please note that calls may be recorded using our leading edge digital
    recording product AudioPC.
    Any opinions expressed in the email are those of the individual and not
    necessarily of the Company. This email and any files transmitted with it are
    confidential a
    nd solely for the use of the intended recipient. It may
    contain material protected by lawyer-client privilege. If you are not the
    intended recipient or the person responsible for delivering to the intended
    recipient, be advised that you have received this email in error and that
    any use is strictly prohibited. If you have received this email in error ple
    ase notify the Security Manager by telephone on +44 (0)1285 883821 or by
    email to [email protected]

    LV can interface to 232, 485, Devicenet... depending on what the controller has.
    You could find a LV/CVI driver for this (232/GPIB/ethernet only) instrument at http://www.ni.com/devzone/idnet/default.htm . If it's not listed there, it leaves you with one of a couple options. First, I would like you to submit a request for this driver at: http://zone.ni.com/idnet97.nsf/instrumentdriverrequest/
    We develop drivers based on demand and popularity so the more requests we have for it, the greater the possibility that we will develop one.
    If you would like to try developing your own instrument driver (or modify the existing one), we have documentation, model instrument drivers, and driver templates to help at :
    http://www.ni.com/devzone/idnet/development.htm
    We also have a syndicate of third party vendors that specialize in National Instruments' products and services. Some of the vendors specialize in driver development. I would suggest contacting one of the Alliance members at:
    http://www.ni.com/alliance
    An instrument driver is a collection of functions that implement the commands necessary to perform the instrument�s operations. In short, someone read the instrument user manual and implemented some of the functionality in a program for the end user. Instrument drivers are not necessary to use your instrument. They are merely time savers to help you develop your project so you do not need to study the manual before writing a program. With all of this work already done for you in the driver, instrument drivers can significantly reduce development time.
    There are example VI's in LV on Instrument Connectivity. If you go to the Help menu >> Examples.. >> I/O, you will see a couple and Examples.. >> Fundamentals for File and String manipulation. I would suggest tweaking them to suit your application. Also the specific command that your instrument responds to can be found from it's manual.
    Some useful resources for your application are
    ni.com > NI Developer Zone > Development Library > Instrument Connectivity
    http://search.ni.com/?col=alldocs&layout=TechResources&ql=a , to search examples and knowledge bases
    Hope this helps.

  • Has anybody got a labview driver for Lecroy 9410 ?

    Has anybody got a labview driver for Lecroy 9410 ?

    Unfortunately I was unable to find a driver for this instrument either. This leaves you with one of a couple options. First, I would like you to submit a request for this driver at:
    http://zone.ni.com/idnet/other.htm
    We develop drivers based on demand and popularity so the more requests we have for it, the greater the possibility that we will develop one.
    If you would like to try developing your own instrument driver (or modify the existing one), we have documentation, model instrument drivers, and driver templates to help at :
    http://zone.ni.com/idnet/development.htm
    We also have a syndicate of third party vendors that specialize in National Instruments' products and services. Some of the vendors specialize in driver development. I would sugges
    t contacting one of the Alliance members at:
    http://www.ni.com/alliance
    If you have any further queries, please let me know

  • Does sombody have a labview driver for the Scanlab rtc2 scanner controller

    From the German firm Scanlab we have a RTC2 isa card with a dll. Has somebody already written a labview driver for this card ?
    greetings from the Netherlands

    Hello Martin,
    First, don t worry it shouldn t be very complicated  I work at a reasearch center with physicist and an hospital with physicians, we probably work on something very similar, like eye surgery assisted by laser
    1- First thing first, does your scanner works with the examples provided with Scanlabs? ex.: "Hpgl.exe" with an "*.PLT" file?
    2- If so, have a look at my load correction subVI, I always do a reset before I start working with the scanner control, only once at the beginning. If the function returs :"0" zero, it s working if not, come back to me.
    regards
    Lukasz
    Attachments:
    LOAD CORR FILE (SubVI).vi ‏9 KB

Maybe you are looking for

  • After upgrading from ASA 8.2 to 9.1(2) not able to get web site

    Dears, ASA Version has been upgraded from 8.2 to 9.1(2). Since then, website is not accessible from outside. Diagnosis: Many web sites are deployed behind the ASA. When anyone accesses website from outside, the following error is reported: The page c

  • NAT ASA5512 8.6(1)2 in and out

    Hello Everyone, This is my first post so please forgive me if I miss something. I have an ASA5512 running 8.6(1)2 that I am trying to NAT a public IP address from my ISP to multiple phone systems on the inside of my network. One of these phone system

  • The performance of TransparentLoad

    On usermanaged cache group, I use the query of 'select * from table where keyvalue=?'     to transparentLoad into TT 1M rows from Oracle database. It costs 852s. Even when I set Logging=0,DurableCommits=0,LockLevel=1 for the data store, It still cost

  • Camera Raw Apparently Missing On Second Installation Of Elements 10

    I have installed Elements 10 onto my desktop which works fine. When opening a .NEF file or when opening a JPEG using 'Open As Raw', the Camera Raw interface comes up. I have also installed Elements 10 onto my netbook. Whilst the prgram itself works f

  • "New root object" menu not available

    I'm using SJS Directory Server 5.2patch3 on Solaris 9, installed silently through state file and all seems to work fine (even if I don't understand why I have to repeat the installation more than one time since the first one doesn't create the proper