BX MASTER-how to set up PCI slot to be a BUS MASTER

Hi, trying to install NIC EN1207D ,but when I go to check IP address ,it says "Media disabled".Running WIN ME ,installed drivers OK ,ACCTON(NIC manufacturer) says it needs to be installed on PCI BUS Master .How do I do that on this mobo .Thanks. ?(

I think they mean install the card in a PCI BUS Master slot (try another slot).

Similar Messages

  • Do I need a PCI slot that is a bus master to use DMA transfers?

    I want to install 3 PCI-6534, 1 PCI-6602, 1 PCI-6115 S board in a Industrial PC with a single board computer. Do all the PCI slots need to support "bus mastering" to us the DMA of all the boards?

    Hi Chris,
    Yes all the PCI slots must support bus mastering. That is the only way for our cards to take control and transfer data via DMA. Most PCs (including industrial PCs with PCI-to-PCI bridges) support bus mastering on all slots. If bus mastering happens to be disabled, here are some steps to change that in the bios:
    1. Reboot your computer. Watch for the message during reboot that instructs you on how to enter the BIOS/Setup. Some systems have these messages disabled, so you may need to check your computer's user manual for the keys to hit. Most computers use a function key (e.g., F1, F2, or F10), but it depends on the system.
    2. Once you enter the BIOS/Setup, look for an menu or option that will allow you to view settings for the PCI Bus. Typi
    cal menus will have names like "Advanced" or "Computer Setup". Some systems do not give you access to the settings for the PCI Bus, so if you do not see anything, check with your computer manufacturer for assistance.
    3. Look for an option to "Enable Bus Mastering" and select it.
    4. Save your setting and exit.
    I've also included some links to other helpful knowledge bases and a tutorial I found on the subject.
    Troubleshooting PCI-GPIB, PCI-DAQ, PCI-MXI-2, PCI-IMAQ Installation Problems
    http://digital.ni.com/public.nsf/websearch/F85046CC4811C066862566480065A34C?OpenDocument
    Why I Am Having DMA Problems with Image Acquisition in Windows NT?
    http://digital.ni.com/public.nsf/websearch/7ECD76F2F87299E8862564EB005A2F1F?OpenDocument
    An Excellent Tutorial on PCI Buses and Mastering
    http://www.pvinc.com/tutorial/tutorial-PCIbus.htm
    Hope that helps. Have a good day.
    Ron
    Applications Engineer
    National Instruments

  • How to reconfigure Cards installed in PCI slots

    Hi All
    My customer has OEL linux. installed on his HP DL380 G7 server. It has 4 Emulex LPe11002 dual port cards installed. The cards in PCI slot 3 and 5 are needed for network connection.
    So he needs to configure the cards in PCI slot 3 and 5 to be used for the network using port 0 on the cards.
    Any guidance help would be appreciated.
    Thanks

    those are HBA FC cards
    What protocol your costumer want to have on those cards?
    IPoFC ?if yes, I haven't done my self, how ever, I did read about time ago, and looks like due the costs of the hardware/switch, all the progress went to 10GE/24GE and infini band.
    not sure if IPoFC is something in the normal skill set of a linux sysadmin.
    What's the speed of those FC cards and switches?
    Alvaro

  • How to set up slider mobile menu widget on master and pages of mobile website in Muse

    Adobe Muse Slider Mobile Menu Widget by MuseThemes
    I am new to mobile website design and Muse, I love this widget, but I am not sure how to set it up on multiple pages.
    Do I put it on the master? Content covers it when it is on master, so I could use some help.
    Thanks so much, anyone know of tutorials or can anyone give me a game plan to set up. thanks so very much!

    Thanks, my issue was that the content was in front of the navigation menu see screen shot (taken in preview in Muse)

  • No ISA slot available in PC. How can I use PCI-85 Modbus Plus card with Lookout?

    My application is to communicate with two Modicon PLCs using Modicon's ModBus Plus (PCI based PCI-85) network card inside my PC, and using Lookout as an SCADA software. Since there is no ISA slot available in new PCs, I can not use Modicon's ISA-85 Modbus Plus networc card. But Lookout does not support PCI based PCI-85 card, how can I use PCI-85 card then, with Lookout? Why doesn't Lookout support it? I asked the following question from from the Modicon's representative about it:
    If I purchase Modbus Plus Driver Suite CD (SWMXDS001, 05, or 10 etc),will I be able to use Lookout SCADA software (by the way, it supports standard MB+ prtocol) for my application? If yes, can I use any version of an
    y of the ISA, PCI, or PCMCIA based MB+ card?
    His answer was:
    The Modbus Plus Driver Suite will talk to any version of card, PCMCIA, ISA, and PCI. The question now is will the SCADA package you are
    planning on using be able to talk to the Modbus Plus Driver Suite? You must contact National Instruments and ask them if they support Modbus Plus, and if
    they used the MB+ system developement kit to develop their product. Or if they wrote their own MB+ drivers, do they work with Modicon hardware?

    Hi,
    currently Lookout does not support the PCI-85 card. The only card supported for Modbus Plus is SA-85. Please see for further information:
    Where can I Find Drivers for Communicating to PLCs, RTUs, and Other Industrial Hardware?
    How to configure the SA-85 card for Modbus Plus
    Hope this helps
    Roland

  • How to set custom master page for social/sites.aspx in sharepoint 2013

    How to set custom master page for social/sites.aspx in sharepoint 2013.?
    File path is
    C:\Program Files\Common Files\microsoft shared\Web Server Extensions\15\TEMPLATE\FEATURES\SocialDataStore\SocialDataStoreList\sites.aspx
    Thanks in advance

    Hi,
    You could open the sites.aspx in Notepad or SharePoint designer, and set the master page to your own master page directly via editing:
    <%@ Page language="C#" MasterPageFile="~masterurl/custom.master"      Inherits="Microsoft.SharePoint.Portal.WebControls.FollowedContentWebPartPage,Microsoft.SharePoint.Portal,Version=15.0.0.0,Culture=neutral,PublicKeyToken=71e9bce111e9429c"
    %>
    Regards,
    Rebecca Tu
    TechNet Community Support

  • How to set default field values in customer master data.

    hi,
    I want to set default values in customer master data (account group wise).
    but
    I don't know how to set it .
    please help me.
    (I don't want to change field status in account group rather than I want to set default values for field. )
    thank you.

    hi,
    this is to inform you that,
    in SAP there is no such a provision.
    but
    in LSMW there is an option of CONSTANT VALUES.
    check in SHD0 - also
    please check and confirm
    balajis\a

  • Strange Case..!! How 2 set an item as a master block to it's db items block

    Hello All,
    i have a question pls.
    ================
    How 2 set an item as a master block to it's related db items in the same data block; as follows:
    ============
    1-i have to enter the item's value ('LAB_TEMP' ) once then;
    2-the other related items in the same data block r changed record each time i navigate to the next record but this item is never changed in this case only if i re-entered another value as (master-detailed rel.). i tried to copy the value of this item to a display item called 'Temp' but it is changing according to the records frequency by default
    ===========================================================
    I tried the following code on when-new-record-instance & on post-changed Triggers as follows:
    ============================================================
    IF :LAB_TEMP IS NOT NULL THEN
    SET_ITEM_PROPERTY ('LAB_TEMP',ENABLED,PROPERTY_FALSE);
    SET_ITEM_PROPERTY ('LAB_TEMP',NAVIGABLE,PROPERTY_FALSE);
    SET_ITEM_PROPERTY ('TEMP',VISIBLE,PROPERTY_TRUE);
    SET_ITEM_PROPERTY ('LAB_TEMP',VISIBLE,PROPERTY_FALSE);
    :TEMP := :LAB_TEMP;
    ELSE
    SET_ITEM_PROPERTY ('LAB_TEMP',ENABLED,PROPERTY_TRUE);
    SET_ITEM_PROPERTY ('LAB_TEMP',NAVIGABLE,PROPERTY_TRUE);
    SET_ITEM_PROPERTY ('TEMP',VISIBLE,PROPERTY_FALSE);
    SET_ITEM_PROPERTY ('LAB_TEMP',VISIBLE,PROPERTY_TRUE);
    :TEMP := :LAB_TEMP;
    END IF;
    ============================================================
    even this generates unable to set enable property or visible prop. error
    ====================================================
    Someone help me with this pls.??
    ========================
    Thanks in advance,
    Regards,
    Abdetu..

    Hello everyone,
    This issue was solved as:
    ==================
    1-i created a separate db block
    2-created a text item called 'TEMP' with db=NO
    3-In the db block that i want to deal with it as:Master item to it's other related detailed items to that item which is called 'LAB_TEMP' ;
    * Copy value from property: TEMP.
    By this way i could entered a value i the ndb item called TEMP once & consequently this value is entered copyed 4 each new record i entered.
    This is an intial solution works fine at least 4 now, a Fried helped me with this i would like 2 share this info 2 others may be a new idea would help...
    Thanks always,
    Abdetu..

  • How to set the field SKB1-FDLEV as requestred-entry in G/L Master data?

    Hi All,
    Could anyone tell me how to set the field SKB1-FDLEV as requestred-entry in G/L Master data?
    Thanks
    Gandalf

    hi
    Go to OB26
    select Your criteria ( create, change or display)
    double click on it
    again double click on Bank/financial details
    there you will find the Planning level make it require entry
    save
    with regards
    ramanuja chary

  • How to set 'Material Master' tab as default in standard transaction CG54?

    Hi All
    I am having a requirement to call the transaction CG54 from a custom program. On calling the transaction, I need to put some default values to the input fields and the default tab selected should be 'Material Master'. I am able to default input fields using BDC Transaction call. Can anybody guide me how to set Material Master tab as the default tab selected?
    Thanks in advance
    Rinzy Deena Mathews

    Hi All
    Solved the issue by myself.
    Initialization of tab in transaction CG54 is based on the values in the standard table TCGSGP - EHS: Search parameter (reproduction from SET/GET memory).
    Calling of the transaction CG54, with default values and parameters can be done with the help of following standard function module:
    *-- Types
      TYPES : BEGIN OF t_obj_tab.
              INCLUDE STRUCTURE rcgapplobj.
      TYPES : END OF t_obj_tab.
      TYPES : tt_obj_tab  TYPE t_obj_tab OCCURS 20.
      TYPES: BEGIN OF t_zplm02,
               sbgvid TYPE zppr_de_sbgvid,
             END OF t_zplm02.
    *-- Internal Tables
      DATA: li_obj_tab    TYPE tt_obj_tab WITH HEADER LINE,
            li_report     LIKE rcgstdrecn OCCURS 20 WITH HEADER LINE,
            li_variant    LIKE rcgstdrecn OCCURS 20 WITH HEADER LINE,
            li_subid_tab  TYPE espre_subid_rep_tab_type WITH HEADER LINE,
            li_report_m   LIKE rcgstdrecn OCCURS 20 WITH HEADER LINE,
            li_variant_m  LIKE rcgstdrecn OCCURS 20 WITH HEADER LINE,
            li_subid_tab_m TYPE espre_subid_rep_tab_type WITH HEADER LINE,
            li_zplm02     TYPE STANDARD TABLE OF t_zplm02.
    *-- Structures
      DATA: ls_addinf     TYPE rcgaddinf,
            ls_rcgradmsel TYPE rcgradmsel,
            lw_zplm02     TYPE t_zplm02.
    *-- Variables
      DATA: lv_trtype     TYPE rcgdialctr-trtype VALUE 'D',
            lv_actype     TYPE rcgdialctr-actype VALUE 'D',
            lv_viewappl   TYPE tcgl3-repappl     VALUE 'MATMASTER',
            lv_sel_valdat TYPE rcgradmsel-valdat,
            lv_sel_langu  TYPE rcgradmsel-langu,
            lv_ucomm      TYPE syucomm,
            lw_gen        TYPE char10,
            lv_flag       TYPE esp1_boolean,
            lv_werks      TYPE werks_d,
            lv_bsbgvid    TYPE zppr_de_bsbgvid.
    *-- Parameters
      ls_addinf-aennr      = sy-datum.
      ls_addinf-valdat     = sy-datum.
      ls_rcgradmsel-sbgvid = iw_gen.
      ls_rcgradmsel-matnr  = p_matnr.
      ls_rcgradmsel-namcat = 'MATNR'.
      ls_rcgradmsel-reprefflg = abap_true.
      ls_rcgradmsel-numcat = 'NUM'.
    *-- Application Object
      li_obj_tab-repappl = 'MATMASTER'.
      li_obj_tab-objectkey = p_matnr.
      APPEND li_obj_tab.
    *-- Evaluate selection screen and fill keytab
      CALL FUNCTION 'C1G0_KEYTAB_FILL_FROM_RADMSEL'
        EXPORTING
          i_radmsel             = ls_rcgradmsel
          i_valdat              = ls_addinf-valdat
          i_actype              = lv_actype
          i_flg_popup_no_param  = abap_true
        IMPORTING
          e_flg_cancel          = lv_flag
        TABLES
          i_applobj_tab         = li_obj_tab
          e_keytab_report       = li_report
          e_keytab_variant      = li_variant
          e_subid_refreport_tab = li_subid_tab
        EXCEPTIONS
          OTHERS                = 1.
    *-- Initilize Report Header Buffer
        CALL FUNCTION 'C1AP_ESTDH_BUF_INIT'
          EXPORTING
            i_aennr  = ls_addinf-aennr
            i_valdat = ls_addinf-valdat.
    *-- Parameters
        ls_addinf-aennr      = sy-datum.
        ls_addinf-valdat     = sy-datum.
        ls_rcgradmsel-sbgvid = iw_gen.
        ls_rcgradmsel-matnr  = p_matnr.
        ls_rcgradmsel-namcat = 'MATNR'.
        ls_rcgradmsel-reprefflg = abap_true.
        ls_rcgradmsel-numcat = 'NUM'.
    *-- Application Object
        li_obj_tab-repappl = 'MATMASTER'.
        li_obj_tab-objectkey = p_matnr.
        APPEND li_obj_tab.
    *-- Initial report block tree of information
        CALL FUNCTION 'C1G2_ENTRY_INQUIERY'
          EXPORTING
            i_trtype              = lv_trtype
            i_actype              = lv_actype
            i_addinf              = ls_addinf
            i_viewappl            = lv_viewappl
            i_sel_valdat          = lv_sel_valdat
            i_sel_langu           = lv_sel_langu
            i_rcgradmsel          = ls_rcgradmsel
          IMPORTING
            e_okcode              = lv_ucomm
          TABLES
            i_keytab_report       = li_report
            i_keytab_variant      = li_variant
            i_subid_refreport_tab = li_subid_tab
            i_applobj_tab         = li_obj_tab.
    With Regards
    Rinzy Deena Mathews.

  • How to set custmer master block for posting & how to set the status .....

    < MODERATOR:  Message locked.  Please read the [Rules of Engagement|https://www.sdn.sap.com/irj/sdn/wiki?path=/display/home/rulesofEngagement] before posting next time. Use an appropriate subject in your message thread. >
    Hi ...
    How to set custmer master blocked for posting & how to set the status has deleted. please provide the steps for the above two actions.
    thanks

    Hi,
    U can use T-code FD05 for Blocking the customer and
    T-code FD06 in order to set for deletion,
    Assign Points if useful,
    Regards,

  • How to set up the output device in output determinatin with customer master

    Hi,
    I am doing the output determination using customer master and not conditions technique.  Can anybody please let me know how to set up the output device . I have done the following:
    1)  assigned output determination procedure DB00001 to acct group 0001
    2)  added output type BA00 to customer master documents tab with print as the medium.
    3)  On creating a sales order and changing it its giving the message
    BA00     515     No printer defined for output BA00
    Please provide me with some suggestions , how to resolve this issue.
    thanx
    Jayant

    1. tcode V/30 -> check BA00 type -> goto  "print" tab -> what's set in the "print param." field?
    2. IMG ->SD -> basic functions -> output control -> define print parameters -> V1 output -> for BA00 output type -> Assign a default printer. This is related with the "print param." set in step 1.
    For example: if "print parame." is set to '1' in V/30, then the default printer is assigned to sales organization.
    You can check F4 search help on the "print param." field (in V/30) to see what options you have.
    If you want to specify printer by customer account, you may need to use userexit.
    Edited by: Harry Wu on Jun 23, 2010 9:18 AM

  • How to set up replenishment or what must maintain in master data?

    I seted up replenishment in master data but it was not available when the stock less than minimum. So I will set what and How to set it.

    1) MAintain min. bin quantity and max bin quantity in WM2 view of material master.
    2)Whenever the bin quantity will fall below the min. bin quantity system will propose for replenishment.
    3) This is valid only for fixed bin so fixed bin needs to be maintained in WM2 view of material master.
    4) Run LP21 and system will create a TR automatically

  • How to set master cost center to required input in the maintaining position

    Dear experts,
             I have two questions in the HCM module,could you please tell me?
    Issue 1: How to set the column of master cost center to required input in the maintaining position screen?
    Issue 2: some of position has two cost center, i have maintained two cost center(cost center 1:90%,cost center 2:10%) percentage in the tab of cost distribution with trasaction code ppome.when i post to accounting,it only post to master cost center 100%,it can not distribute two cost center, Could you please tell me the reason?
    Looking forward to your reply.
    Best regards,
    Merry

    HI,
    Plz check with ur FICO Consultants as master Cost Center r desgined by them
    They will Loop group of Cost Centers to Master Cost Center.
    This concept has started in ECC 6.0 Version 
    Regards,
    Kiran

  • How to set unequal columns using master pages in InDesign CS3?

    How to set unequal columns using master pages in InDesign CS3?

    I don't have CS3 anymore but I don't think this has substantially changed in the last few versions of InDesign.
    Choose View > Grids & Guides > uncheck Lock Column Guides. Then drag the column guides to the position you want.

Maybe you are looking for

  • Opening Hyperlinks in New Browser Window?

    Hi All, Does anyone know how to have keynote open a hyperlink in a new browser window? I have exported my keynote presentation to a quicktime moive and posted it on the web. However, when someone clicks on one of the hyperlinks it opens the new websi

  • Icon Preview Problem in Finder

    Hi, I've had my new MacBook for about a month now, and as my photo collection has grown I'm starting to notice that while using CoverFlow (which I have as the default view for most of my folders), there are always some icons that appear as a generic

  • Phantom wireless network!

    Hi. I'm not really sure what piece of hardware or software is causing this problem, so this may not be the right place to ask, but here's the deal: I have a wireless network consisting of a Linksys WRT54G (The one pretty much everyone has), a PowerBo

  • Downloaded the pdf converter to word....how do I run the program?

    downloaded the pdf converter to word....how do I run the program?

  • Slow typing input

    Hi. I put a Microsoft Word file in my Dropbox then opened it in Pages on my iPad. It is about 7 pages long with many bullet points. When I am editing the file in Pages the typing input is terribly slow, I can type an entire sentence before it appears