C220 M4 w/ VIC1225 and Nexus 5548

I have four UCS C220 M4 servers that each have a VIC 1225 and are connected up to a Nexus 5548.  I have set them to trunk ports and have set the appropriate VLANs in ESX and the portgroups.  I can ping the gateway and other hosts on the network, but for some reason I can't ping any of the other C220 M4 servers that have a VIC1225.  All of the C220's can ping other devices on the network, but not each other.  Is there some setting I need to modify on the VIC or switch?  Currently the VIC is running as Classical Ethernet mode.

There is no special configuration to make connectivity work in the rack servers, I assume these servers are in standalone mode and not integrated with UCSM.
What L3 device is doing your Inter-Vlan routing? Is it the N5K these servers are connected to or there is another device doing this job?   If it is the N5K, are all the servers in the same network segment? I mean, is there a single SVI or multiple?  can your Nexus 5K ping each of the servers?
-Kenny

Similar Messages

  • Prime Infrastructure 2.0 and Nexus 5548, SSH credentials fail

    Hi,
    I'm having problem getting the Prime Infrastructure 2.0 to login with SSH to a Nexus 5548 to do an inventory. I get "Wrong Telnet/SSH credentials". But when I use the same credentials from another SSH-client it works fine. I also tested to SSH from the console of the Prime-server and that also works fine.
    Any ideas???
    Regards,
    Stefan Lindkvist

    I have PI 2.0 working against Nexus 5k's in two different installations. See below for an example (click to enlarge).
    Have you put in an entry in both the login and enable fields (even though they are not separately required when logging in directly)?

  • Adapter-fex Supported VICs and Nexus Switches

    HI,
    I am thinking of using C220M4 in standalone mode. I have been reading about adapter-fex and I am wondering which Cisco VIC supports adapter-fex and which Nexus Switch will support adapter-fex.
    I am thinking of using a VIC1225 and Nexus 3000.
    Thanks.

    I believe that adaptor fex is supported only with Nexus 5k and N2k:
    Network Adapter Virtualization Design (Adapter-FEX) with Cisco Nexus 5500 Switches and Cisco Nexus 2232 Fabric Extenders
    http://www.cisco.com/c/en/us/products/collateral/switches/nexus-5000-series-switches/guide_c07-690080.html
    http://www.cisco.com/c/en/us/products/collateral/switches/nexus-5000-series-switches/data_sheet_c78-657397.html

  • FCoE with Cisco Nexus 5548 switches and VMware ESXi 4.1

    Can someone share with me what needs to be setup on the Cisco Nexus side to work with VMware in the following scenario?
    Two servers with two cards dual port FCoE cards with two ports connected to two Nexus 5548 switches that are clusterd together.  We want to team the ports together on the VMware side using IP Hash so what should be done on the cisco side for this to work? 
    Thanks...

    Andres,
    The Cisco Road Map for the 5010 and 5020 doesn't include extending the current total (12) FEX capabities.  The 5548 and 5596 will support more (16) per 55xxk, and with the 7K will support upto 32 FEX's.
    Documentation has been spotty on this subject, because the term 5k indicates that all 5000 series switches will support extended FEX's which is not the case only the 55xx will support more than 12 FEX.  Maybe in the future the terminology for the 5k series should be term 5000 series and 5500 series Nexus, there are several differences and advancements between the two series.

  • Fabric with two Nexus-5548 and a brocade switch does not get fabric updates

    We have a fabric containing two Nexus 5548 and a Brocade 5000 switch in interop mode 2. When i make changes to the zoning, the first nexus (the fabric principal) and the brocade switch see the zone changes. The second Nexus switch does not see it. There are no error messages but  the change just can't be seen.  What can i do to find out, what goes wrong ?

    Ouch, deprecated is not the word i wanted to read
    We are using 5.1(3)N1(1a) on nexus-rz1-a
    and 6.0(2)N1(2) on nexus-rz2-a.
    The fabric can be seen :
    nexus-rz2-a# show fcs ie vsan 10
    IE List for VSAN: 10
    IE-WWN                   IE     Mgmt-Id  Mgmt-Addr (Switch-name)
    10:00:00:05:1e:90:57:27  S(Rem) 0xfffc01 10.88.133.110 (bc-san1)
    20:0a:00:2a:6a:72:ba:01  S(Loc) 0xfffc1c 10.88.133.105 (nexus-rz2-a)
    20:0a:54:7f:ee:7f:dc:01  S(Adj) 0xfffc0b 10.88.133.100 (nexus-rz1-a)
    [Total 3 IEs in Fabric]
    nexus-rz1-a# show fcs ie vsan 10
    IE List for VSAN: 10
    IE-WWN                   IE     Mgmt-Id  Mgmt-Addr (Switch-name)
    10:00:00:05:1e:90:57:27  S(Adj) 0xfffc01 10.88.133.110 (bc-san1)
    20:0a:00:2a:6a:72:ba:01  S(Adj) 0xfffc1c 10.88.133.105 (nexus-rz2-a)
    20:0a:54:7f:ee:7f:dc:01  S(Loc) 0xfffc0b 10.88.133.100 (nexus-rz1-a)
    [Total 3 IEs in Fabric]
    I try to distribute the zoneset this way:
    zoneset distribute vsan 10
    Zoneset distribution initiated. check zone status
    nexus-rz1-a# show zone status
    VSAN: 10 default-zone: deny distribute: full Interop: 2
        mode: basic merge-control: allow
        session: none
        hard-zoning: enabled broadcast: disabled
    Default zone:
        qos: none broadcast: disabled ronly: unsupported
    Full Zoning Database :
        DB size: 6291 bytes
        Zonesets:1  Zones:62 Aliases: 44
    Active Zoning Database :
        DB size: 10243 bytes
        Name: FABRIC1  Zonesets:1  Zones:60
    Status: Zoneset distribution completed at 08:06:00 UTC Dec  3 2013
    nexus-rz2-a# show zone status
    VSAN: 1 default-zone: deny distribute: active only Interop: default
        mode: basic merge-control: allow
        session: none
        hard-zoning: enabled broadcast: disabled
    Default zone:
        qos: none broadcast: disabled ronly: unsupported
    Full Zoning Database :
        DB size: 4 bytes
        Zonesets:0  Zones:0 Aliases: 0
    Active Zoning Database :
        Database Not Available
    Status:
    VSAN: 10 default-zone: deny distribute: full Interop: 2
        mode: basic merge-control: allow
        session: none
        hard-zoning: enabled broadcast: disabled
    Default zone:
        qos: none broadcast: disabled ronly: unsupported
    Full Zoning Database :
        DB size: 6291 bytes
        Zonesets:1  Zones:62 Aliases: 44
    Active Zoning Database :
        DB size: 10243 bytes
        Name: FABRIC1  Zonesets:1  Zones:60
    Status: Activation completed at 13:03:42 UTC Dec  2 2013

  • FCoE using Brocade cards CNA1020 and Cisco Nexus 5548 switches

    All,
    I have the following configuration and problem that I am not sure how to fix:
    I  have three Dell R910 servers with 1TB of memory and each has two  brocade 1020 CNA cards dual port.  I am using distributed switches for  the VM network and a second distributed switch for VMotion.  I have two  of the 10G ports configured in each distributed switch using IP Hash.   The management network is configured using a standard switch with two 1G  ports.
    The  Nexus configuration is we have two nexus 5548 switch connected together  with a trunk.  We have two VPC's configured to each ESX hosts  consisting of two 10gig ports in each VPC with one port going to each  switch.  The VPC is configured for static LAG.
    What  I am seeing is that after a few hours the virtual machines will not be  accessible via network anymore.  So if you ping the VM it will not work  and if you get on the console of the VM then ping the gateway then  nothing as well but if you try to ping another virtual machine on the  same host on the same VLAN then it will work so traffic is going through  the ESX backplane.  If I reboot the ESX host then things will work  again for another few hours or so then the problem repeats.
    The version of vSphere I am using is ESXi4.1
    Please assist I am stuck.
    Thanks...

    Here is the link for Nexus and Brocade interoperability Matrix
    http://www.cisco.com/en/US/docs/switches/datacenter/mds9000/interoperability/matrix/Matrix7.html#wp313498
    usually this table would show those models those have been tested and verified
    However I do not see  Brocade 5300 listed in the table . It could be, interoperability may have not been tested by both vendors perticularly to 5300 type Model.

  • Nexus 5548 and Define static route to forward traffic to Catalyst 4500

    Dear Experts,
    Need your technical assistance for the Static routing in between Nexus 5548 and Catalyst 4500.
    Further I connected both Nexus 5548 with Catalyst 4500 as individual trunk ports because there is HSRP on Catalyst 4500. So I just took 1 port from each nexus 5548, make it trunk with the Core Switch (Also make trunk from each Switch each port). Change the speed on Nexus to 1000 because other side on Catalyst 4500 line card is 1G RJ45.
    *Here is the Config on Nexus 5548 to make port a Trunk:*
    N5548-A/ N5548-B
    Interface Ethernet1/3
    Switchport mode trunk
    Speed 1000
    Added the static route on both nexus for Core HSRP IP: *ip route 0.0.0.0/0 10.10.150.39 (Virtual HSRP IP )*
    But I could not able to ping from N5548 Console to core Switch IP of HSRP? Is there any further configuration to enable routing or ping?
    Pleas suggest

    Hello,
    Please see attached config for both Nexus 5548. I dont have Catalyst 4500 but below is simple config what I applied:
    Both Catalyst 4500
    interface gig 3/48
    switchport mode trunk
    switchport trunk encap dot1q
    On Nexus 5548 Port 1/3 is trunk
    Thanks,
    Jehan

  • DCBX Between Linux and Nexus QOS

    Hi Guys
    i have a server with 2 physical links only.
    over this link im passing 2 vlans in trunk ( can be Portchannel to VPC or bond active passive , doesnt matter to me ) .
    vlan 302 is for data
    vlan 303 is for backup
    server on vlan 303 is pushing traffic on that link and would take as much
    bandwidth as we would give it , and would therefore cause communication issues to vlan 302 . ( congestion ) .
    I would like to talk about my options here , to avoid congestions .
    thought about enabling dcbx on clients ( linux ) and pfc ( priority flow
    control ) to be able to negotiate qos and bw allocation according to COS IEEE 802.1p .
    the idea is to have either the traffic prioritized/limit/shaped before/when its ingressing the nexus port .
    the dcbx looks very cool like i said , it's kind of like what the nexus has with the CNA Card .
    when it can send the linux nic through dcbx the qos parameters to apply ! ( ah ok , i see now its exactly the same )
    ps linux dcbx link : http://manpages.ubuntu.com/manpages/precise/man8/dcbtool.8.html
    Ingress Queuing Policies
    You can associate an ingress policy map with an Ethernet interface to guarantee bandwidth for the specified traffic class or to specify a priority queue.
    The ingress policy is applied in the adapter to all outgoing traffic that matches the specified CoS value.
    When you configure an ingress policy for an interface, the switch sends the configuration data to the adapter. If the adapter does not support the DCBX protocol or the ingress policy type-length-value (TLV), the ingress policy configuration is ignored.
    did anyone here tried it or implemented dcbx before ?
    anyway id be happy to hear your wise and helpfull suggestions please
    Thanks Thanks !!!

    Found the answer.
    Anatomy of RX packet counters on a Cisco Nexus 5548:
    Nexus5548# show int eth1/29 
      RX      
        6387682660 unicast packets  1495485 multicast packets  164 broadcast packets 
        6389178309 input packets  589693485138 bytes
        5146969 jumbo packets  0 storm suppression bytes
      * "input" = unicast + multicast + broadcast (all non-jumbo)
      * "jumbo" = frames sized 1519 bytes to the MTU bytes defined on the interface
      * "jumbo" frames are counted separately from non-jumbo ("input")
      * (unicast, multicast and broadcast "jumbo" frames appear to be rolled into the 
            one "jumbo" counter)
    This can be seen another way with the 'count detail' command, correlated to "show int" output:
    Nexus5548# show int eth1/29 count detailed
    Ethernet1/29
      Rx Packets:                                  6389178309 <-- input
      Rx Unicast Packets:                          6387682660 <-- unicast
      Rx Multicast Packets:                           1495485 <-- multicast
      Rx Broadcast Packets:                               164 <-- broadcast
      Rx Jumbo Packets:                               5146969 <-- jumbo
      Rx Bytes:                                  589693485138
      Rx Packets from 0 to 64 bytes:                  1059418 <-- non-jumbo start
      Rx Packets from 65 to 127 bytes:             6072007478       +
      Rx Packets from 128 to 255 bytes:              11055520       +
      Rx Packets from 256 to 511 bytes:             287107435       +
      Rx Packets from 512 to 1023 bytes:             12801466       +
      Rx Packets from 1024 to 1518 bytes:                  23 <-- non-jumbo end
      Rx Trunk Packets:                            6387682823 <-- unicast + broadcast
    fyi.

  • Telephony Issues on Nexus 5548

    Dear Viewers,
    I have Nexus 5548 devices in one of my client data centers and i have one 3750 switch to which all of these Avaya voice servers connect.
    The 3750 switch was initially connected through a L2 Link to a 6509 catalyst switch and the telephony applications were working correctly.
    The problem arises when i move this 3750 layer 2 link to a Nexus 5548 (OS version 5.1(3)N1 switch. All telephony calls coming from the outside (External calls) are not working as required but the internal calls work as usual.
    What is odd is that when i migrate this L2 link back to the 6509 switch, all works as usual. This is just a layer 2 connection and i am wondering why this is not possible.
    The vlan is accepted on all relevant trunks. I also deactivated igmp snooping on this voice vlan on the Nexus 5548 thinking it would help but in vain.
    Any ideas and suggestions are welcome.
    regards.
    Alain

    This is my radius config......  on a 5K
    radius-server timeout 7
    radius-server host 10.28.42.20 key 7 "Password" auth-port 1645 acct-port 1646 authentication accounting
    radius-server host 10.28.42.21 key 7 "Password" auth-port 1645 acct-port 1646 authentication accounting
    aaa group server radius Radius-Servers
     server 10.28.42.20
     server 10.28.42.21
    aaa authentication login default group Radius-Servers
    ip radius source-interface Vlan1
    aaa authentication login default fallback error local
    And it is currently working. On the radius server i also had to do this to make the users admins once logged in:
    https://supportforums.cisco.com/document/137181/nexus-integration-admin-access-free-radius

  • Install pbr feature nexus 5548

    I am in need of Policy Based Routing for a new project.  At my core I have a couple of Nexus 5548s clustered together.  I go into configure terminal and run the command "feature pbr" and the return is invalid.  So I check the license with the command "show license usage" and I get the following output:
    Feature                      Ins  Lic   Status Expiry Date Comments
                                     Count
    FCOE_NPV_PKG                  No    -   Unused             -
    FM_SERVER_PKG                 No    -   Unused             -
    ENTERPRISE_PKG                Yes   -   Unused Never       -
    FC_FEATURES_PKG               Yes   -   Unused Never       -
    VMFEX_FEATURE_PKG             No    -   Unused             -
    ENHANCED_LAYER2_PKG           No    -   Unused             -
    LAN_BASE_SERVICES_PKG         Yes   -   In use Never       -
    LAN_ENTERPRISE_SERVICES_PKG   Yes   -   Unused Never       -
    From here I see that the enterprise package is installed and is unused.  How can I gain access to the enterprise features?  I found a document here that says "Ensure that you are in the correct VDC (or use the switchto vdc command). "  The switchto vdc command is also invalid.  What am I missing?
    Eric

    I realise this is a very old post however I wanted to post here in case others are still looking for this feature. PBR is now supported in version 6.0(2)N2(1) on Nexus 5k.
    RELEASE NOTES: http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5500/sw/release/notes/6_02/Nexus5500_Release_Notes_6_02.html#pgfId-472355

  • TACACS Nexus 5548 Authorization

    I am having an issue with authorization on the Nexus 5548. Note: The tacacs configuration has and still works correctly with all non-Nexus gear.
    Authentication succeeds, and initiatial authorization passes. However, all sh and config commands fail, though AAA Autho Config-Commands .... and Commands Default Group <Grp Name), are configured.
    ACS generates the following error: 13025 Command failed to match a Permit rule. The Selected Command Set is DenyAllCommands. I created an AllowAll, but am unclear how to associate this with Access Policy.
    Any help would be greatly appreciated.

    Hello,
    Hope the attached document points you into the right direction.
    Regards.

  • Nexus 5548 L3 daughter card flapping

    Hi guys,
    Anyone of you here that experienced the logs below on their Nexus box:
    2011 Dec 12 06:24:45 GDCNXS5K01 %BTCM-2-BTCM_LOG_ROUTER_ERR: router card in slot 3 has internal link(s) flapped:     router ports down: 0x1a108000 0x1a109000 0x1a10a000 0x1a10b000 0x1a10c000 0x1a10d000 0x1a10e000 0x1a10f000
    I am getting this log at least once a day. Seems like it is shutting down the SVI of the box after the said log occured. Good thing I have enable vPC and I am able to access the NXS5K through the vCP keepalive link (mgmt).
    I have two Nexus 5548, but only one is experiencing the said error.
    Any inputs, suggestions would be greatly appreciated.
    Thanks,
    Edzel

    We had this same problem this past weekend, only in module 2 on a 5596.
    In our case, we had rebooted our primary Nexus and found the following message immediately preceeded the BTCM error you noted:
    %$ VDC-1 %$ %NOHMS-2-NOHMS_DIAG_ERROR: Module 2: Bootup diag detected major event: Forwarding ASIC failure: Ethernet2/9 Ethernet2/10 Ethernet2/11 Ethernet2/12 Ethernet2/13 Ethernet2/14 Ethernet2/15 Ethernet2/16
    We replaced the module.  A "show diag results module 3" would probably show you the same thing.  However, I don't think the error message will show up until you reboot.
    If your flapping Nexus is secondary, you probably won't notice anything major, but if it is your primary, it would probably affect your routing.

  • Servers connected to Nexus 5548 only getting 200 Mbps of throughput

    Servers connected to NExus 5k were only getting 100 Mbps of throughput. So I disabled Flow control recieve on all the ports. After this we are getting 200 Mbps of speed. The servers are connected throuh 10 gig port. Could you guys please suggest why the throguhput is still low? Atleast we should get 1Gbps of thrpoughput.

    Hi Adam,
    I think we probably need a little more information to go on. Can you answer the following?
    What type of servers and NICs?
    What OS are you running on the servers?
    What cables do you have from the servers to the switch?
    Are the two servers in the same subnet or is the traffic between them routed?
    If routed, is that in the Nexus 5548 or some other router?
    How are you testing throughput?
    Presumably you're not seeing any errors on the switch ports that the servers are connected to?
    Regards

  • Configuring FET-10G-SR for NEXUS 5548/2248

    Hey everyone-
    I am a little newer with configuring switches and routers, and I have been asked to troubleshoot a FET-10G-SR in our NEXUS 5548 and NEXUS 2248.  I am aware that the ports need to be configured to except FET parts, and I have tried using the "switchport mode fex-fabric" command to configure the ports, but the command will not work for some reason. Can anyone help me with configurations step by step to have these parts work properly? Any help will be greatly appreciated. Thank you!
    Chris Hazell

    It should normally work unless the port is not the proper type of has a configuraiton applied that's incompatible.
    Can you provide the output for "show run int eth ___" and "show int eth___" (substituting your interface number for the "___") for the interface in question?
    Also, if it's the first fex you are adding, you must have enabled "feature fex" globally.

  • EEM on Nexus 5548

    Hi all,
    I'm new to EEM and we are investigating using it to solve some issues that we are having, However, I can't seem to find any definitive information which tells me whether EEM is available in the nexus 5548 switches. Can anyone here help to confirm if this is the case? If not yet avalable for the 5548s, are there any indications as to when it might become available?
    thanks,
    Ram

    Might want to try the 6.0(2)N1(2) and later code.  I have it loaded on a N6004 and EEM is available there.  It is of course the NX-OS flavor of EEM but it is there. 
    N6K-Switch# show ver | grep 'System version'
      System version: 6.0(2)N1(2)
    N6K-Switch# conf t
    Enter configuration commands, one per line.  End with CNTL/Z.
    N6K-Switch(config)# event manager ?
      applet       Create/Modify an Event Manager Policy
      environment  Configure an environment variable
      policy       Register a script policy and activate it
    N6K-Switch(config)# event manager
    Mike

Maybe you are looking for

  • Please assist: NoClassDefFoundError: com/sun/msv/datatype/xsd/IntType

    Hi, I've developed a very simple schema and used jaxb of jwsdp-1.2 to generate the related data model. After that, I created a number of generated objects, and marshaled them out to an XML file. It worked perfectly, however, after making some unrelat

  • How to have button in down state as page opens

    On opening a new "blank" subsidiary page using "getURL", there are 2 buttons on the new page. Each button plays a moveclip. (The first movieclip is already playing as the new page opens). I'd like to have the corresponding button already in the down

  • Oracle Express Tips/Whitepapers on Design and Performance ?

    Hi all, I was wondering if someone could please provide me with some information to find Articles / White Papers / Tips on Oracle Express, design and performance tuning etc., Thanks for your help in advance. RN null

  • Trying to insert this color picker. Javascript Question.

    This is what I would like to do: jQuery Color Picker, Selector, Chooser Plugin - colpick.com This is the code: <div class="color-box"></div> <div class="color-box"></div> <div class="color-box"></div> $('.color-box').colpick({ colorScheme:'dark', lay

  • Anyone using Grid Control in a non-Oracle VM environment ?

    We are setting up a VMWare system for our databaes and application servers. SInce we're not using Oracle's VM product... does any one have any experience with using VMWare ? Any tips suggestions ? I am attempting to figure out how the agents would pi