C460 Rack Server with two VIC 1225 - UCSM vNIC placement policy
I am trying to integrate C460 having 2 VIC 1225 cards with UCSM. The objective is to have 2 ethernet interfaces assigned to each VIC , one per FI.
vNIC 1 on VIC 1 - FI A failover to FI B
vNIC 2 on VIC 1 - FI B failover to FI A
vNIC 3 on VIC 2 - FI A failover to FI B
vNIC 4 on VIC 2 - FI B failover to FI A
I have created a service profile with 4 vNICs and assigned to C460. When the UCSM is configured to use the system default for vNIC/vHBA placement policy, all 4 vNICs are assigned to one VIC. When trying to place them manually with 2 on vCon1 and 2 on vCon2, I am seeing insufficient resource error. Both the VIC are recognized and UCSM server tab shows both of them as adapters.
Could someone please let me know how to achieve it?
Thanks!
The C460 has an integrated BCM 57711 which would also be recognized by the system. What's most likely happening is that the VIC 1225s are on vCon1 and vCon3 and the BCM card is on vCon2, since FF is not supported on the Broadcom adapter this would cause the association to fail. Try placing the manual placement with vCon1 and vCon3 and see if this clears up the issue.
Steve McQuerry
UCS - Technical Marketing
Similar Messages
-
C460-M2 with 2 VIC-1225, managed by UCSM
C460-M2 with 2 VIC-1225; all documents show only one VIC-1225 (which has to be in PCI slot nr.1) single wire managment with a UCS FI ?
Is this a limitation ? or must the second VIC-1225 be connected to a switch outside the FI ?
Walter.I received the following answer
Good question Walter. The documentation is confusing. If running the C460 as part of a UCS integration, only 1 card is supported.Although the server supports 2 cards , slot 1 & 2 according to the specsheet. The datasheet states that upto 3 VIC can be supoprted int he server.
The Cisco CCW config tool allows you to configure 2 VIC1225 in the C460.
From the 460 spechseet.
http://www.cisco.com/en/US/prod/collateral/ps10265/ps10493/ps11587/spec_sheet_c17-662220.pdf
Page 24
The C460 server accommodates the Cisco 1225 Virtual Interface card, which is supported only in slots 1 and 2. Note, however, that if the server is running UCSM, only slot 1 is supported for the VIC card.
■ The Cisco Card NIC mode is currently supported only with a Cisco 1225 VIC (UCSC-PCIE-CSC-02) that is installed in PCIe slot 1.
■ The C460 server accommodates the Cisco 1225 Virtual Interface card, which is supported only in slots 1 and 2. Note, however, that if the server is running UCSM, only slot 1 is supported for the VIC card.
From the datasheet
http://www.cisco.com/en/US/prod/collateral/modules/ps10277/ps12571/data_sheet_c78-708295.html
System Requirements
The Cisco UCS VIC 1225 is designed for use only on Cisco UCS C-Series Rack Servers. A single Cisco UCS VIC 1225 is supported on Cisco UCS C260 M2, C460 M2, C220 M3, C240 M3, C22 M3, and C24 M3 rack servers. Up to three Cisco UCS VIC 1225 cards are supported on these servers depending on the slot configuration.
Anyone at Cisco want to clarify the above?
Message was edited by: NABIL YAGHI -
SCCM central site and primary site use the same SQL SERVER with two Instance.
Hi Guys,
I want deploy SCCM 2012 central site and primary site in my domain. But Only one Sql server for me. Any one can tell me how to install the central site server and primary site server with the same SQL SERVER with two instance.
Please remember to click “Mark as Answer” on the post that helps you, and to click “Unmark as Answer” if a marked post does not actually answer your question. This can be beneficial to other community members reading the thread.
Sean Xiao
TechNet Community SupportAlthough you can install like the configuration you said above, we do not recommend you do it this way. If your SQL box has problems, all the data will go away and you will not have data redundancy.
You need to configure the different SQL Port and SQL Broke service port e.g.
SQL port 4023 SQL Broke Service port 4022 for CAS instance
SQL port 4024 SQL Broke Service port 4021 for PRI instance
Juke Chou
TechNet Community Support
I agree with Johan and this configuration should not be used. But I want to clarify that the default ports for "SQL port" (actually, SQL over TCP) is 1433 and the SQL Broker Service uses 4022. The configuration above should work but the "correct" would be
to use 1433 and 4022 for the CAS and 10434 and 4023 for the Primary :)
You can read more about Network Ports used by Configuration Manager here
http://technet.microsoft.com/en-us/library/hh427328.aspx#BKMK_CommunicationPorts
/Tim
Tim Nilimaa | Blog: http://infoworks.tv | Twitter: @timnilimaa -
Mac Mini Server with two displays
I am about to purchase the new MMS, but I want to clarify two things first.
I just got off the phone with Apple Customer Service. I asked them, if it's possible to connect two displays, one via Thunderbolt, the other via mini port at full 2500x1440 res. The guy said, it's possible with two Thunderbolt displays, however, he seemed not to sure about it. Further, he couldn't say anything about the possibility of connecting one Thunderbolt and an older Cinema display at full res.
Does anybody know?
Thanks!I'm not sure about the full res on HDMI. They always had the dual link adapter for the mini display port, not sure how this HDMI one will work out. Maybe they'll offer a special adapter in time?
You can see the available ports here: http://www.apple.com/macmini/design.html
and tech info here: http://www.apple.com/macmini/specs.html -
C Series Rack Server-possible to manage via UCSM although diferent location
Hello,
Is it possible to have a C series rack server link up to a UCS domain in another location? We have a campus environment and in the location where we are considering a rack server, there is no existing UCS domain/6248 interconnects. There is however, a Cisco Nexus 5000. Not sure if that helps.Hello Allan,
Please refer to the link which will surely help you to resolve your query-
http://www.cisco.com/en/US/docs/unified_computing/ucs/c-series_integration/ucsm2.1/b_UCSM2-1_C-Integration_chapter_010.html -
VPN Server with two router local network
I just got a Mac Mini Server 2011 to set up as a home server. One of the main features I want to use is a VPN so I can access my files on my local network when I'm away from home. I live in Japan and I have a Japanese optical connection to the internet that runs through two boxes before I can use it in any form: some sort of modem, and a "gateway" which I literally just found out is also acting as a router and serving DHCP addresses. In addition, I have a 2TB Time Capsule that, until just recently, I had been using in the "Share a Public IP" mode because I didn't realize the gateway was also issuing DHCP addresses. I cannot simply plug my TC into the modem in place of the gateway - both are required to access the internet.
Until today I had both routers using DHCP on the local networks they each created. Under that environment, I had finally configured Lion Server to file share (easy), manage network accounts (moderate), and serve Profile Manager (difficult). But despite my best efforts at mapping the ports on the Time Capsule, I just couldn't get the ports open using tools like canyouseeme.org, so the VPN was a no-go. That's when I realized the gateway could be a router too, so with some creative google searches, and extensive use of google translate, I was able to figure out how to open ports on the gateway. It does it pretty differently from the Time Capsule and other routers I've seen. It asks you define the host on the LAN (what i assume to be the target IP), the protocol (TCP vs. UDP), and then a range of ports for it to open. I plugged in the IP of the Time Capsule, opened all the UDP ports (since it was an option to just open all, and I figured 1) the TC would still protect my network and 2) it would just be a test), but I still couldn't see the ports as being open.
So then I got desperate, and I switched the TC back to Bridge Mode, reconfigured the Server and my MBP (my client Mac) to the new IP addresses being served by the Japanese gateway, and tried again. I think I reconfigured the DNS settings in Server Admin properly to account for the change in IP, and then updated the services in Server.app, but now I can't even get to my server homepage (the apple placeholder page) using either its IP or its .private domain, and to make matters worse, I STILL can't seem to get the ports open (yes, I changed the port mapping to send it directly to the server IP as the target after the change).
To add insult to injury, the wired ethernet connection I had been running from my TC to the MM Server is now reporting a cable unplugged (it's not), even when I plug it directly into the gateway, though I am able to connect wirelessly.
Does anyone have any idea what's going on? Why can't I get these ports open? (By the way, I called my ISP and they said they aren't blocking any of the ones I'd want to use for VPN.)
What is the *better* set up - using the TC as a second LAN, serving its own DHCP addresses, or using it in Bridge mode?
Why did these changes sever my wired connection?
I was getting even more problems (like loss of internet connectivity on all devices) using the TC in bridge mode, so I decided to go back to the dual network setup.Hello Eric,
As I mentioned above.
For external Internet access, I would create a Generation
1 VM
and use 2 Legacy Network Adapters for
the Interfaces . Connect it to the External and Internal network, and then install VM Linux IPFire (How
to install) and
configure IPFire with RED and GREEN interface.
You don't need router or any firewall.
I have the same set-up that you are trying to do in your lab and it's working great.
All my VMs / computers on the LAN have their gateway the Linux VM.
Hope this help.
Regards,
Charbel Nemnom
MCSA, MCSE, MCS, MCITP
Blog: www.charbelnemnom.com
Please remember to click “Mark as Answer” on the post that helps you, and to click “Unmark as Answer” if a marked post does not actually answer your question. This can be beneficial to other community members reading the thread. -
New physical server - with two DC's - need help!
My scenario is I have a small business who has two locations. The "IT" guy is set in a way that he wants to do this, and he has contracted me to help.
Site 1
192.168.1.x network
SBS 2003 server (on really old hardware) Lets call this server SBS1
Site 2
192.168.2.x network
Is a domain controller thats a global catalog. The two sites replicate. Lets call this server Server2
SIte 2 Site VPN between the two offices
The OLD IT guy took an image of the SBS server six months ago, and put it on newer hardware. But it was never implemented. Since 6 months ago, not much has changed, a few new PC's and a few new users.
The current "IT" guy wants to put the imaged SBS that is the newer hardware server into the network and decom the old SBS server.
The network can be taken down, and downtime is okay. This doesnt need to a quick drop in and go.
My concern is, if I drop in the imaged server of the SBS server that was done six months ago, its going to look and say hey, there are some accounts that I dont have, so im going to remove them from Server2.
Whats the best way going about this?
I have suggested some other routes, but the "IT" guy is insistent on doing this, and well he's paying me by the hour so im fine following his lead.
Also the "IT" guy is willing to recreate missing user accounts if that happens.Some more information, the SBS server is not really being used as an SBS server. Exchange is not running, no sharepoint, etc.
Its basically a file server, print server, and DC.
When they did the image -this was six months ago-, they just cloned the old SBS server to new hardware. Now the IT guy wants to drop that cloned SBS server onto the network. I know i'll have to re copy all the users data files, etc.
I just need to know how AD is going to react. Is the Server 2, going to push its AD updates to the SBS server because its 6 months old? Or will the SBS say, hey im supposed to be the main DC, so update to my old information?
Are there any other huge issues that could happen? The image being six months old, is that going to cause huge issues with replication?
Should I just take a new image and put onto the server that currently has the six month old image?
Please help. Thank you. -
Is a one server with two system IDs configuration valid when using MSCS
As the last step in my upgrade from BW30b to BI70 I need to introduce Java.
My newly upgraded ABAP BI70 system is running on a Microsoft Cluster and it was my intention to add Java as a separate system(SID). When doing this it appeared I would be able to add the two systems to the same cluster group by selecting "Support of multiple SAP systems in one MSCS cluster" but this resulted in errors and I have found note 967123 which tells me not to chose this option when using MSCS.
It appears my options are a separate server all together or an ABAP+Java install which limits our upgrade options on each stack.
If anyone has found a work around for this I would be very interested.
Thank youHi Helmut,
Not sure how the D-Link works, but it looks like it has Wireless 802 also from the specs, so the Ethernet & Wireless would each have an IP & different MAC addies.
I always thought one Mac address can have only one IP address.
Nope, you can prove this to yourself on your Mac, In Network>Show:>Network Port Configurations, highlight say Ethernet, Copy, give that another IP Manually if you wish... -
UCS C-Series VIC-1225 to Nexus 5000 setup
Hello,
I have two nexus 5000 setup with a vpc peer link. I also have an cisco c240 m3 server with a vic-1225 card that will be running esx 5.1. I also have some 4 2248 fabric extenders. I have been searching for some best practice information on how to best setup this equipment. The nexus equipment is already running, so its more about connecting the c240 and the vic-1225 to the nexus switches. I guess this is better to do rather than to connect to the fabric extenders in order to minmize hops?
All documention I have found involves setup/configuration etc with fabric interconnects which I dont have, and have been told that I do not need. Does anyone have any info on this? and can point me in the right direction to setup this correctly?
More specifically, how should I setup the vic-1225 card to the nexus? just create a regular vpc/port-channel to the nexuses? use lacp and set it to active?
Do I need to make any configuration changes on the vic card via the cimc on the c240 server to make this work?Hello again, Im stuck
This is what I have done. I have created the vPC between my esx host and my two nexus 5000 switches, but it doesnt seem to come up:
S02# sh port-channel summary
Flags: D - Down P - Up in port-channel (members)
I - Individual H - Hot-standby (LACP only)
s - Suspended r - Module-removed
S - Switched R - Routed
U - Up (port-channel)
M - Not in use. Min-links not met
Group Port- Type Protocol Member Ports
Channel
4 Po4(SD) Eth LACP Eth1/9(D)
vPC info:
S02# sh vpc 4
vPC status
id Port Status Consistency Reason Active vlans
4 Po4 down* success success -
vPC config:
interface port-channel4
switchport mode trunk
switchport trunk allowed vlan 20,27,30,50,100,500-501
spanning-tree port type edge trunk
vpc 4
interface Ethernet1/9
switchport mode trunk
switchport trunk allowed vlan 20,27,30,50,100,500-501
spanning-tree port type edge trunk
channel-group 4 mode active
Im unsure what I must configure on the cisco 240M3(esx host) side to make this work. I only have the two default interfaces(eth0 and eth1) on the vic-1225 installed in the esx host, and both have the vlan mode is set to TRUNK.
Any ideas on what I am missing?
Message was edited by: HDA -
Issues configuring VIC 1225 in C240
I'm trying to configure a C240 server with the VIC 1225 installed.
First off, I'd like to know if it's even possible to use this without Fabric Interconnects or Nexus switches. Assume I'm just hooking them up to some regular 10GbE switches. I can change this but wante to have a better idea of my design decisions - not a lot of info regarding when the VIC 1225 can or should be used outside this context.'
Secondly, I am following the directions here:
http://www.cisco.com/en/US/docs/unified_computing/ucs/c/sw/cli/config/guide/1.4.1/b_Cisco_UCS_C-Series_CLI_Configuration_Guide_141_chapter_01001.html#task_3C31BD7B25BF4CF6839B7B12DE014482
I've verified that the VIC is installed in slot 1 visually as well as through the output below, but the output below isn't what I expected per the documentation. I'm not able to get into the scope of this adapter, and it's showing up in "show pci-adapters" and not "show adapters". It's like it's not even being recognized as a VIC.
Any help would be appreciated.
ucs-c240-m3 /chassis # scope adapter 1Error: Managed object does not exist, use show command to list valid targetsucs-c240-m3 /chassis # scope network-adapter 1Error: Managed object does not exist, use show command to list valid targetsucs-c240-m3 /chassis # scope pci-adapter 1% Incomplete commanducs-c240-m3 /chassis # scope pci-adapter 1 <CR> Press Enter keyucs-c240-m3 /chassis # scope adapter Cisco Systems UCS Virtual Interface Card dimm-summary Information common to all DIMMs fan-policy Fan Policy parameters firmware Get all Components Firmware flexflash Cisco FlexFlash Controller gpu Show GPU cards present in the system hdd Host local hard disk drive network-adapter Show network adapters present in the system storageadapter RAID Controllerucs-c240-m3 /chassis #Matt,
The VIC 1225 is fully supported as a stand-alone card outside of UCSM and by default it runs in Classical Ethernet mode which means it's supported with any IEEE standard 10GE switch.
The VIC is not supported in Slot 1 in the C240, it is supported in Slot 2 or 5
(http://www.cisco.com/en/US/docs/unified_computing/ucs/c/hw/C240/install/replace.html#wp1337242).
Without being installed in the proper slots, the NC-SI connector at the end of the PCIe bus will not be conencted and the CIMC has no interface to to configure the card. Once you have installed it in a supported slot you should be able to scope chassis and show the adapter. Then scope to the adapter as shown below
ucs-c240-m3# scope chassis
ucs-c240-m3 /chassis # show adapter
PCI Slot Product Name Serial Number Product ID Vendor
2 UCS VIC 1225 FCH162974VP UCSC-PCIE-C... Cisco Systems Inc
ucs-c240-m3 /chassis # scope adapter 2
ucs-c240-m3 /chassis/adapter #
Once you are able to see your VIC let me know if you have additional questions.
Steve McQuerry
UCS - Technical Marketing -
C240 M3 with VIC 1225 VMware network issue
Just got my hands on a few C240 M3′s with the VIC 1225 adapter and began setting them up as a VMware 5.1 U1 cluster. I’ve configured 8 vNICs per host: 2 for Management, 2 for VMotion, 2 for iSCSI, and 2 for VM traffic. Each pair of vNICs has one pinned to uplink 0 and the other to uplink 1. vNICs are set to trunk mode in the VIC since I am tagging multiple VLANs from VMware. The hosts are physically connected to a stacked pair of Cisco 4500-X switches; physical uplink 0 to one switch, uplink 1 to the other switch. Switch ports are trunked to allow the VLANs we plan to use. Portfast is enabled. VMware vSwitches using Source Port ID for Load Balancing and the vNICs are active/active for Management and VM traffic. No port channel or Etherchannel is configured on the swtiches.
After creating a VM for vCenter and joining the hosts to it, I started migrating existing VMs from an old cluster and saw odd network behavior. It seems whenever a VM or vmkernel interface are on any vNIC pinned to the same physical uplink on the same host, they can’t talk to each other.
Example: VM1 and VM2 are on host 1. VM1′s network adapter is pinned to vNIC1 using VLAN 10 which uses physical uplink 0. VM2′s network adapter is pinned to vNIC2 using VLAN 10 which uses physical uplink 1. VM1 and VM2 can ping each other. If I move VM2′s network adapter to any vNIC that uses physical uplink 0, just like VM1, then VM1 and VM2 can no longer ping each other. Or if host 1′s management IP is pinned to vNIC 1 on physical uplink 0, any VM on host 1 using a vNIC also pinned to physical uplink 0 cannot ping the host.
Anyone have any ideas? Is something configured incorrectly on the switch? On the VIC?
Thanks!Hello Michael,
I assume VIC is operating Classical Ethernet ( CE ) mode and VM1 and VM2 are in different vswitchs for the non-working scenario, ( where there vNICs used by vSwitch are pinned to physical uplink ) .
If this is the scenario, the frames have to be switched upstream switch and needs to be forwarded back on the same switch interface. Any IEEE standards based switch will not forward such traffic flow.
You might want to take advantage of Adapter-FEX or adapt changes to design to accommodate such traffic flows.
HTH
Padma -
C240 with VIC 1225 : enable Failover
Hi,
I have a C240M3 with a VIC 1225. I would want to enable failover.
In order that, i have to enable NIV mode. But it seems to me that i could not.
Why ????
how to solve this issue ???
C240-FCH1749V0VC /chassis/adapter # set
cli CLI options
description Adapter description
fip-mode Enable/disable FIP
vntag-mode Enable/disable VNTAG
niv-mode not present.....
C240-FCH1749V0VC /chassis # show adapter 2 detail
PCI Slot 2:
Product Name: UCS VIC 1225
Serial Number: FCH17457ESH
Product ID: UCSC-PCIE-CSC-02
Adapter Hardware Revision: 6
Current FW Version: 2.1(3a)
VNTAG: Disabled
FIP: Enabled
Configuration Pending: no
CIMC Management Enabled : yes
VID: V03
Vendor: Cisco Systems Inc
Description:
Bootloader Version: 2.1(3a)
FW Image 1 Version: 2.1(3a)
FW Image 1 State: RUNNING ACTIVATED
FW Image 2 Version: 2.1(3a)
FW Image 2 State: BACKUP INACTIVATED
FW Update Status: Idle
FW Update Error: No error
FW Update Stage: No operation (0%)
FW Update Overall Progress: 0%
C240-FCH1749V0VC /chassis #
any detail on NIV
My C240 is connect to Catalyst 3750.
Many thx.
Nicolas.Hello Kenny,
My main question is « how to use and to configure failover on VIC 1225 ». I have already configure failover on B-serie but never on c-series
For more details (please see diagram in attach), my issue is that my C240 on DRP site (just 40 metres from main site) is connected to local switch (C3560) and to LAN core (C4506 on main site). This connection on 2 Catalyst devices seems to be a problem for vSphere :
i could see that : as soon as I connect the 2 ports, C240 lost connection to vCenter ; CIMC is still pinging.
I could read on ucsguru forum, someone has the same issue with 2 catalyst.
I do not have a lot of time for this deployment and installation. So, I told me to use actif/passif should be the faster way. If I connect only a cable (by shuting/ no shuting an interface on a catalyst), it works. In order to do that, automatically, I would want to implement failover on VIC1225
Any suggestion on my issue is welcome.
Many thanks.
Nicolas. -
Memory for Cisco C200m2 rack server
Hi
I have an C200m2 rack server with 3x2GB of ram memory. I want to extend that to atleast 12Gb of ram how should
Add 1st 8GB module = 3X2GB + 8GB
or remove the old memory and replace it with 3x4GB
//THi Tobias ,
Check this information:
When considering the memory configuration of your server, you should consider the following items:
•DIMMs within the server should all be the same type, speed, and size. Do not mix different size DIMMs or DIMMs with different clock rates in the same server. Doing so causes the system to set the memory system speed to that of the slowest installed DIMMs.
•DIMMs can be used either in a one DIMM per Channel (1DPC) configuration or in a two DIMMs per Channel (2DPC) configuration.
•There are blue and black DIMM slots. Populate blue slots in a bank first.
Please check the link for further details:
http://www.cisco.com/en/US/prod/collateral/ps10265/ps10493/c200m2_lff_specsheet.pdf
Hope this help!
David -
Sql server with multiple instance
hi All,
i want to install sql server with two instance and i want to assign two separate is ips for both default instance and named instance and both should work like
two different server
note: If i logged with one ip(default instance) it should show its own databases not both or named instance databases
thanks
chintalaHi chintala,
According to your description, if you want to assign the two different IP to stand for default instance
and named instance, I recommend you set up aliases on a SQL Server with multiple instances. For example, a physical server is named WinServer and 2 instances of SQL Server named WinServer and WinServer\instance1.
We need to add 1 IP addresse to the WinServer, there is one IP address already assigned to WinServer, 192.168.1.1, by adding one new IP's, 192.168.1.2 .
We need to move into DNS to configure our host names and aliases. The physical machine must be steup as a static IP in DNS. SQLAlias1, which point to the default instance on WinServer, will be setup as a DNS with an address of 192.168.1.1.
SQLAlias2, which will point to WinServer\Instance1, will be setup as a new Host (A) record in DNS with an address of 192.168.1.2.
When everything has been completed on the DNS side, you need to open up SQL Server Configuration Manager on WinServer and configure the protocols for each instance one at a time, restart the 3 SQL services.
For more information about how to set up aliases on a SQL Server with multiple instances, you can review the similar article.
http://kevine323.blogspot.com/2013/08/setting-up-aliases-on-sql-server-with.html
Regards,
Sofiya Li
Sofiya Li
TechNet Community Support -
Multiple ESS access to single EP server from two backend servers.
Hi Experts,
I have one concern regarding ESS.
Can we do or can we make two ESS access (R3 server1 and R3 Server2) from one Portal server.
I heard that from one portal server (ESS) we can connect multiple clients which are from backend R3 (example client 100 and client 200)
My requirement is :
We have two R3 backend servers and one EP(ESS) server.
Can we access two backend systems from one EP server with Two ESS tabs.
I am expecting Multiple jco settings, multiple SSo, Multiple SLD, Multiple SPRO Menu settings, UWL settings.
Multiple service specific settings to be access by using single EP server(Multiple ESS Tabs)
Please help me for doing this.
Regards
Kumar.yes you can do so As Pooja indicated also refer
Please have a look at the Note 596698
Thanks for clearing that up, Now if I understand the issue
correctly :
1 Portal, Two backend R/3 System, This can be done, Now then
if you dont want the particular application disable that
r/3 as you are aware that the links appear from V_T7XSSSERRES.
Here you can also make sure some applications appear or no.
Accessing multiple Backends in WebDynpro:
How it can be done?
1) Define different JCO Destinations
The logical System names have to be defined in the Web Dynpro Content
Administrator.
Different clients or completely different Systems can be accessed
given that the function modules called exist in those systemsThe logical System to be used can be passed to the Web Dynpro
Application by using a URL Parameter
The URL Parameter can be easily maintained in the iView Property when
using the portal.
The standard way to handle this is to create copies (via delta-link) of
all the business package iviews and change the 'System' property in the
newly created iviews to point to the correct system Alias. From the
portal point of view this is all that is required in order to point an
view to a different system
Refer these links for further information:
https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/com.sap.km.cm.
docs/library/webas/webdynpro/How%20to%20Use%20the%20Web%20Dynpro%20Conte
nt%20Administrator.pdf
Maybe you are looking for
-
How can I identify and delete duplicates on the latest version of itunes?
How can I identify and delete duplicates on the lastest version of iTunes?
-
Need help with Java Programming
Hello All, I dont know how to save all the lines separatly and then work with the numbers? Example TxtIn: 2 5 0 9 2 3 4 // I dont know how many lines will appear, and dont know how many numbers in a line 1 2 3 9 1 5 4 2 0 0 5 6 2 5 1 9 4 6 1 5 4 9 1
-
Hey I updated to the 4.3.4 program today and since then I have no key tones or Msg tones anyone else having this problem or have a solution?? my Ringtone is fine!!
-
I have a problem with nokia 5000.I want to have that digital clock as screensaver and I know that must make the following settings: Power saver: off Sleep mode: off Screensaver: digital clock but at my nokia 5000 i don't have power saver to set of
-
Navigation to "Multi Query Data Explorer portal takes more time than single Query Data Explorer. Is there any way to optimize the screen navigation? I have copied the "Custom Control Central Portal" from Demo environment.