Call LSMW from a Module pool screen

Hi SAP gurus,
In order to call an LSMW from a module pool screen, there is a Function module which I have used earlier, but unable to recollect it. Can someone please tell me the FM which we need to use ?

Sudhakar,
Create an LSMW and assign it to a tcode and then call this tcode from the module pool program so that it  will skip all the screens just by allowing the user to input the files and run the lswm.
Regarding the FM I have no idea.
K.Kiran.

Similar Messages

  • Regarding exit from the module pool screen

    h experts,
    i have developed a module pool report in which in the selection screen i have four fields which are mandatory ,when i execute the program without entering in the selection screen it do not allow to come out of the module pool screen ...what i want that without entering any input in the selection screen if i press exit button push button it will allow to come out of the screen for this what sud i do plz help me....

    Hi
    keep a button called <b>EXIT</b> on the screen
    Make the function type of that field as <b>E</b>
    in Flow logic write
    PROCESS AFTER INPUT.
    Forced Exit from the transaction from screen
      MODULE exit AT EXIT-COMMAND.
    double click on exit module and
    then in PAI write
    *&      Module  exit  INPUT
    Exit from the Transaction
    MODULE exit INPUT.
      CASE okcode.
        WHEN 'EXIT' OR 'CANCEL'.
          CLEAR okcode.
          LEAVE PROGRAM.
      ENDCASE.
    ENDMODULE.                 " exit  INPUT
    <b>Reward points for useful Answers</b>
    Regards
    Anji

  • Passing Data to Webdynpro from normal module pool screen

    Hi,
    I am working on a requireent, where I have a normal screen with some fields and a button. When I click on the button I want to navigate to the webdynpro screen and also pass the data from the screen to web dynpro.
    Any suggestion is really appriciated.
    Thanks
    Sanjaya

    Hi Sanjaya,
      DATA lv_app TYPE swfvtv-vval.
      DATA lv_url TYPE string.
      DATA lv_url_pre TYPE string.
      DATA lv_url_suff TYPE string.
      DATA lv_task TYPE swfvtv-task.
      DATA lv_memid TYPE string.
      DATA lt_param TYPE tihttpnvp.
      DATA ls_param TYPE LINE OF tihttpnvp.
      DATA lo_window_manager TYPE REF TO if_wd_window_manager.
      DATA lo_api_component  TYPE REF TO if_wd_component.
      DATA lo_window         TYPE REF TO if_wd_window.
    Get Application Name.
      lv_task = sworklist-external_type.
      DATA lt_swfvtv TYPE TABLE OF swfvtv.
      DATA ls_swfvtv TYPE swfvtv.
    Get WD parameters
      SELECT *
      FROM   swfvtv
      INTO   CORRESPONDING FIELDS OF TABLE lt_swfvtv
      WHERE  task EQ lv_task
      AND    vtyp EQ 'WD_ABAP'.
      IF sy-subrc NE 0.
        RAISE not_found.
      ENDIF.
    Create application name in PAPPL
    Get namespace
      READ TABLE lt_swfvtv INTO ls_swfvtv WITH KEY vpar = 'NAMESPACE' .
      IF sy-subrc EQ 0.
        CONCATENATE pappl ls_swfvtv-vval INTO pappl SEPARATED BY '/'.
      ENDIF.
    Get application name
      READ TABLE lt_swfvtv INTO ls_swfvtv WITH KEY vpar = 'APPLICATION' .
      IF sy-subrc EQ 0.
        CONCATENATE pappl ls_swfvtv-vval INTO pappl SEPARATED BY '/'.
      ENDIF.
    Construct URL for application name.
      lv_url = pappl.
      CALL METHOD cl_wd_utilities=>construct_wd_url
        EXPORTING
          application_name = lv_url
          in_parameters    = lt_param
        IMPORTING
          out_absolute_url = lv_url.
      SPLIT lv_url AT '?' INTO lv_url_pre lv_url_suff.
      IF lv_url_suff IS NOT INITIAL.
        CONCATENATE '&' lv_url_suff INTO lv_url_suff.
      ENDIF.
      CONCATENATE lv_url_pre '?sap-client=' sy-mandt '&sap-language=' sy-langu lv_url_suff '&WI_ID=' sworklist-external_id
    INTO   lv_url.
    Create window for application.
      lo_api_component  = wd_this->wd_get_api( ).
      lo_window_manager = lo_api_component->get_window_manager( ).
      lo_window         = lo_window_manager->create_external_window(
                            url = lv_url
                            has_menubar = abap_false
                            has_toolbar = abap_false
                            has_location = abap_false ).
      lo_window->set_window_size( width = '700' height = '500' ).
      lo_window->open( ).
    This is the code to generate the URL for a Web Dynpro Application.
    modify the code according to need.
    Hope this will help you.
    Thanks &Regards,
    Arvind
    Hey i dont know why is this coming like this when posted.
    Copy-paste this in modify in editor.
    Edited by: Arvind Patel on Jun 16, 2010 2:35 PM

  • How to call program in the Module pool screen

    hi ,
    i am having 2 screen when we press enter in first screen we will go to second screen in second screen i want to call a standard ALV program but second screen is already having some fields i want tthis report in down part of the screen
    please help me for that
    Edited by: ankita12345 on Nov 19, 2009 12:27 PM

    Hi,
    Its your choice. If you want a ALV display, then create a custom container and display data like this
    DATA: custom_container1 TYPE REF TO cl_gui_custom_container.
    IF custom_container1 IS INITIAL.
          CREATE OBJECT custom_container1
            EXPORTING
              container_name              = 'CUST_CONT1'
            EXCEPTIONS
              cntl_error                  = 1
              cntl_system_error           = 2
              create_error                = 3
              lifetime_error              = 4
              lifetime_dynpro_dynpro_link = 5
              OTHERS                      = 6.
          IF sy-subrc <> 0.
            MESSAGE ID sy-msgid TYPE sy-msgty NUMBER sy-msgno
                       WITH sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
          ENDIF.
          CREATE OBJECT grid1
            EXPORTING
              i_parent          = custom_container1
            EXCEPTIONS
              error_cntl_create = 1
              error_cntl_init   = 2
              error_cntl_link   = 3
              error_dp_create   = 4
              OTHERS            = 5.
          IF sy-subrc <> 0.
            MESSAGE ID sy-msgid TYPE sy-msgty NUMBER sy-msgno
                       WITH sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
          ENDIF.
          CALL METHOD grid1->set_table_for_first_display
            CHANGING
              it_outtab                     = t_itemdetails[]
              it_fieldcatalog               = t_itemfc
            EXCEPTIONS
              invalid_parameter_combination = 1
              program_error                 = 2
              too_many_lines                = 3
              OTHERS                        = 4.
          IF sy-subrc <> 0.
            MESSAGE ID sy-msgid TYPE sy-msgty NUMBER sy-msgno
                       WITH sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
          ENDIF.
        ENDIF.
    If you want to have a table control, then you can do so. Search the SDN, you will find loads for your reference.

  • How to create select-options on module pool screen

    Hi all
    I want get a range of values from the user from the module pool screen.
    Is there any element available on module pool screen like select options on the selection screen of reports.
    reply me ASAS.
    Thanks.

    hi krishna
    actually I want to display the details of PO numbers from 45000100 to 45000150. user will enter this range on the module pool screen just as we enter on the selection screen of report. My question is do we have a button like select-option on the module pool screen.
    Plz . reply me ASAP.
    Thanks.

  • Call module pool screen from ABAP Webdynpro

    Hi All
    I designed one screen in normal classical dynpro in SE80 for module pool program. I want to call that screen layout design in webdynpro view layout.
    So please help me how can i call that module pool screen from my ABAP webdynpro 

    Hi
    Thank you for your great replay. But Mr Ramakrishnappa and Mr Katrice as your reference i go through that but when i insert the program name and screen number program is end with a run time error saying
    dynamic type conflict when assigning reference.
    Please refer the below snap shot

  • Copying from report output to a module pool screen

    Hi to all experts
    My requirement is to call a transaction when i click a button in module pool programme .when i execute that transaction an alv report is displayed and user selects some records that should be copied over to the module pool screen.

    Yous should use ALV OOps concept to capture the selected data in the ALV report , and once you return back you can update yr module pool .

  • Trigger a workflow from module pool screen at save button

    Hi,
    I am new to workflow.Please help me.My requirement is trigger a custom workflow from module pool screen at save button.
    Scenario is: Create a Z screen for material creation and after pressing save button workflow should trigger to approver and approver emailid should be fetch from Z table and have to provide a link in work flow for Z t-code which displays a report of material pending for approval..
    Please suggest me process how i can acheive this..
    Thanks

    Hi,
    If you're using standard bapi's to save the material, you can then use either the standard events which are already triggered or you coul add a change document for material changes or creation.
    Then this event can be the trigger of your custom workflow.
    Kind regards, Rob Dielemans

  • How to use table maintenance view in module pool screen

    hi ,
    want to use table maintenance view in a module pool screen so that i can edit, insert, delete and update date in to the ztable.please help.

    You can simply call it via SM30.   Or you can call the table maintence view from any program(report or module pool) using a function module.
      call function 'VIEW_MAINTENANCE_CALL'
           exporting
                action                       = 'U'
                view_name                    = 'Z_Table_Name'
           exceptions
                client_reference             = 1
                foreign_lock                 = 2
                invalid_action               = 3
                no_clientindependent_auth    = 4
                no_database_function         = 5
                no_editor_function           = 6
                no_show_auth                 = 7
                no_tvdir_entry               = 8
                no_upd_auth                  = 9
                only_show_allowed            = 10
                system_failure               = 11
                unknown_field_in_dba_sellist = 12
                view_not_found               = 13
                others                       = 14.
    Regards,
    RIch Heilman

  • How to insert tabstrip control in module pool screen painter

    Hi all!
    plz tell e how to use tabstrip control in module pool screen painter.Also plz give me an example program using tabstrip control.

    To insert tabstrip just open layout of screen and press on the tabstrip button there .
    Use this souce code further to activate it .
    CONTROLS tabstrip TYPE TABSTRIP.
    DATA: okcode TYPE sy-ucomm,
    dynnr TYPE sy-dynnr,
    flag type flag,
    active like tabstrip-activetab .
    call SCREEN 100.
    *& Module USER_COMMAND_0100 INPUT
    text
    MODULE USER_COMMAND_0100 INPUT.
    data: lv_okcode type syucomm.
    lv_okcode = okcode.
    clear okcode.
    case lv_okcode.
    WHEN 'TAB1'.
    dynnr = '0110'.
    WHEN 'TAB2'.
    dynnr = '0120'.
    WHEN 'TAB3'.
    dynnr = '0130'.
    WHEN 'TAB4'.
    dynnr = '0140'.
    WHEN 'TAB5'.
    "check authorization, if authorization fails
    flag = 'X'. "set the global flag
    active = 'TAB1'. "store active tab in global variable
    dynnr = '0110'. "set the screen number
    WHEN 'BACK' or 'EXIT'.
    leave program.
    ENDCASE.
    IF lv_okcode(3) = 'TAB'.
    tabstrip-activetab = lv_okcode.
    ENDIF.
    ENDMODULE. " USER_COMMAND_0100 INPUT
    *& Module STATUS_0100 OUTPUT
    text
    MODULE STATUS_0100 OUTPUT.
    SET PF-STATUS 'MAIN'.
    SET TITLEBAR 'xxx'.
    IF tabstrip-activetab IS INITIAL OR
    dynnr IS INITIAL.
    tabstrip-activetab = 'TAB1'.
    dynnr = '0110'.
    ENDIF.
    "set the activetab explicilty here
    if flag eq 'X'. "from authorization failure
    tabstrip-activetab = active. "'TAB1'
    clear flag.
    endif.
    ENDMODULE. " STATUS_0100 OUTPUT

  • Displaying MIR4 attachment list TIF image in module pool screen

    Hi All,
    I have a screen with a custom container and I tried to call a TIF image from MIR4 which is in attachment list(which is stored in archived link).
    I need a function module to display this image in my Module pool screen using the container.
    I tried using below code
    * Create controls
         CREATE OBJECT container_1
           EXPORTING
             container_name = 'CONTAINER'.
    *    create object container_2
    *      exporting container_name = 'PICTURE_CONTROL_2'.
         CREATE OBJECT PICTURE_CONTROL_1
           EXPORTING
             parent = container_1.
    *    CREATE OBJECT PICTURE_CONTROL_2 exporting parent = container_2.
    CALL METHOD PICTURE_CONTROL_1->LOAD_PICTURE_FROM_URL
           EXPORTING
    *    URL    = 'SAPR3://984BE16932C81EE3B2AA1E3B0D12C6FF'
    *      URL    = 'file://E:\Personal\New_Passport4.jpg'
    *       URL    = 'SAPR3://984BE16932C81EE3B2BDF8E44B035648.TIF'
    *URL    = 'SAPR3://SAPR3CMS/get/100/Z1/984BE16932C81EE3B2BDF8E44B035648//.TIF'.
         URL    = 'SAPR3://WebRepository/0020698212/DEMOWORD97SAPLOGO?Version=00000'
         IMPORTING
              RESULT = lv_result.
    CALL METHOD PICTURE_CONTROL_1->set_display_mode
         EXPORTING
           display_mode = PICTURE_CONTROL_1->display_mode_fit_center.
    But I am able to display this URL    = 'SAPR3://WebRepository/0020698212/DEMOWORD97SAPLOGO?Version=00000' and not able to display my archive link image which is in TIF.
    note: Display image of Arc.link Doc.type ZBUSI_TIF (doc.class TIF)
    Please help me on this.
    Thanks
    Geetha Charan

    Hi sai,
    Please refer th procedure.
    For the select-options you might have defined a selection screen.
    Next you can fetch the entire data that you wanted to display in a module pool into an internal table.
    you can call the screen you defined for o/p upon the selection.
    Then, You define a screen XXXX  and a table control in the scree, and in the PAI module of the screen
    you write a chain end chain processing in which you can display the contents of your internal table.
    OR
    if you want the selection also to be in the module pool,  then for displaying the O/P you can definr a sub-screen of the initial screen and you can call that sub-screen on selcting, which can be done with a function code.
    Hope this helps

  • Display Continuous Fluctuations in Input Data in Module Pool Screen

    Dear All,
    We are working on a Weighbridge Interface scenario, where the weighbridge is sending data to a digitizer, which is connected to the COM port of a PC. The objective is to read the data from the digitizer, and display in a Module pool screen. However, there is one more requirement: the weight may fluctuate until it stabilizes, and the fluctuations have to be displayed on screen. For example, the tare weight of a vehicle may be 12.4 TON, but when the vehicle is standing on the weighbridge, the weight may vary from 10.4 to 12.4 TON. The idea is to capture the stable weight, so that any discrepancies can be avoided. In the current IT system implementation, the fluctuations in the weight are displayed. But using ABAP, can these fluctuations be captured? For example, we may design a screen containing a field for capturing the weight, and the weight displayed there automatically refreshes as soon as there is a change in the digitizer reading. Is this possible to achieve? If so, how?
    Awaiting answers.
    Thanks and Regards,
    Sid

    Hi Sid,
    just a suggestion for the refreshing of an ABAP screen: you can use class CL_GUI_TIMER, but it only handles whole seconds, i.e. 1 second, 2 seconds and so on, but not 0.5 seconds...
    An example of an ABAP listing could be the following:
    *& Report  ZZAVV001
    REPORT  zzavv001 NO STANDARD PAGE HEADING.
    CONSTANTS: c_yes(1) TYPE c VALUE 'X'.
    DATA: BEGIN OF t_bseg OCCURS 0.
            INCLUDE STRUCTURE bseg.
    DATA: END OF t_bseg.
    data: d_num_bkpf type i,
          d_num_bseg type i.
    PARAMETERS: interval TYPE i DEFAULT 5.  "meaning 5 seconds
    *       CLASS lcl_receiver DEFINITION
    CLASS lcl_receiver DEFINITION.
      PUBLIC SECTION.
        METHODS:
          handle_finished FOR EVENT finished OF cl_gui_timer.
    ENDCLASS.                    "lcl_receiver DEFINITION
    * Global data
    DATA:
      test       TYPE i,
      receiver   TYPE REF TO lcl_receiver,
      timer      TYPE REF TO cl_gui_timer.
    START-OF-SELECTION.
      CREATE OBJECT timer.
      CREATE OBJECT receiver.
      SET HANDLER receiver->handle_finished FOR timer.
      timer->interval = interval.
      CALL METHOD timer->run.
      PERFORM load_data.   "or whatever you have to do to read the weight
      PERFORM show_list.   "or whatever you have to do to print the weight you've read
    *       CLASS lcl_receiver IMPLEMENTATION
    CLASS lcl_receiver IMPLEMENTATION.
      METHOD handle_finished.
        PERFORM carga_datos.
        PERFORM muestra_listado.
        CALL METHOD timer->run.
      ENDMETHOD.                    "handle_finished
    ENDCLASS.                    "lcl_receiver IMPLEMENTATION
    *&      Form  load_data
    *       text
    FORM load_data.
      clear: d_num_bkpf,
             d_num_bseg.
      select single count( * )
        into d_num_bkpf
        from bkpf.
      select single count( * )
        into d_num_bseg
        from bseg.
    ENDFORM.                    "load_data
    *&      Form  show_list
    *       text
    FORM show_list.
      get time.
      skip to line 1.
      position 1.
      write: / 'Date / Time:', sy-datum, sy-uzeit.
      write: / 'Number of BKPF records:', d_num_bkpf.
      write: / 'Number of BSEG records:', d_num_bseg.
    ENDFORM.                    " show_list
    Okay, it's just a tiny code snippet, but I hope it may help you by designing auto-refreshing screens.
    Kind regards,
    Alvaro

  • Module-pool screen field value under POV event

    Hi All,
    I have one issue...please suggest me solution for this.
    In module-pool program i have one screen(1000) which has one field(hrname_1000).
    Under this event:
    PROCESS ON VALUE-REQUEST.
    FIELD hrname_1000  MODULE hrname_1000.
    under this module hename_1000 i have used F4IF_INT_TABLE_VALUE_REQUEST to put a search help for field hrname_1000.
    after that i am trying to retrive HR related stuff's based on the field on module-pool i.e i am using hrname_1000 in the where condition.
    but problem is that im not getting value for hrname_1000 which im giving in the module-pool screen.
    thats y my select query is not working.
    Where as im getting values for the hrname_1000 under PBO & PAI.
    It will look like below.
    PROCESS ON VALUE-REQUEST.
    FIELD hrname_1000  MODULE hrname_1000.
    (under the above module)
      SELECT DISTINCT ename plans FROM pa0001 INTO CORRESPONDING FIELDS OF TABLE itab WHERE stell = '50001026'.
          LOOP AT itab INTO wa WHERE ename = hrname_1000.
          ENDLOOP.
    Please suggest
    Thanks & regards
    Ansumesh

    In some of the cases the screen field is present in the screen but not holding the value in the required structure or field.
    so here u need to check the option of reading the screen field values explictly..
    //once u hit an enter and do the f4 i think the value will be there ...but if u dont hit enter and do an F4 the value cannot hold and i think u r in this case ..
      1.Fill the screen field name in the structure dynpread.
    DATA: BEGIN OF DYNP_VALUES OCCURS 10.
            INCLUDE STRUCTURE DYNPREAD.
    DATA: END   OF DYNP_VALUES.
    DYNP_VALUES-FIELDNAME = 'HRNAME_1000'.
      APPEND DYNP_VALUES.
    * read screen values
      CALL FUNCTION 'DYNP_VALUES_READ'
        EXPORTING
          DYNAME     = HELP_REPID  "call the repid of ur prog
          DYNUMB     = HELP_DYNNR "pass the screen number
        TABLES
          DYNPFIELDS = DYNP_VALUES
        EXCEPTIONS
          OTHERS     = 1.
    now dynp_values hold the field name and field value of the screen .
    now
    SORT DYNP_VALUES BY FIELDNAME.
        READ TABLE DYNP_VALUES WITH KEY 'HRNAME_1000' BINARY SEARCH.
        IF SY-SUBRC EQ 0.
          HELP_XXXX = DYNP_VALUES-FIELDVALUE. "store the value into a variable
          TRANSLATE HELP_XXXX TO UPPER CASE.               
        ENDIF.
    Now check the code with the value if its getting populated which once there will make ur select work ..
    Vijay..

  • Variants for module pool screena

    Hi,
    I tried creating a variant for module pool screen by using the FM : RS_CREATE_VARIANT.
    For this i created a dummy report which has the same parameters as the fields in the screen.
    CALL FUNCTION 'RS_VARIANT_CONTENTS'
            EXPORTING
              report                      = gc_dummy_rep
              variant                     = 'variant5'
            MOVE_OR_WRITE               = 'W'
            NO_IMPORT                   = ' '
            EXECUTE_DIRECT              = ' '
          IMPORTING
            SP                          =
            tables
            L_PARAMS                    =
            L_PARAMS_NONV               =
            L_SELOP                     =
            L_SELOP_NONV                =
              valutab                     = lt_params
            OBJECTS                     =
            FREE_SELECTIONS_DESC        =
            FREE_SELECTIONS_VALUE       =
          EXCEPTIONS
            VARIANT_NON_EXISTENT        = 1
            VARIANT_OBSOLETE            = 2
            OTHERS                      = 3
          IF sy-subrc <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
            WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
          ENDIF.
    but when i try to retrieve the values stored in the variant using FM : RS_VARIANT_CONTENTS.
    CALL FUNCTION 'RS_VARIANT_CONTENTS'
            EXPORTING
              report                      = gc_dummy_rep
              variant                     = 'variant5'
            MOVE_OR_WRITE               = 'W'
            NO_IMPORT                   = ' '
            EXECUTE_DIRECT              = ' '
          IMPORTING
            SP                          =
            tables
            L_PARAMS                    =
            L_PARAMS_NONV               =
            L_SELOP                     =
            L_SELOP_NONV                =
              valutab                     = lt_params
            OBJECTS                     =
            FREE_SELECTIONS_DESC        =
            FREE_SELECTIONS_VALUE       =
          EXCEPTIONS
            VARIANT_NON_EXISTENT        = 1
            VARIANT_OBSOLETE            = 2
            OTHERS                      = 3
          IF sy-subrc <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
            WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
          ENDIF.
    I get an error message : variant5 not found.
    is there anything that i miss here?
    or is the way i use to create variant for module pool screen not right?
    Regards,
    Kamini

    Hi,
    To avail save variant option in module pool screen,
    1. You need to create a data base table similar to INDX table with the fields RELID, VARI_NAME
    PROG_NAME
    UNAME
    SRTF2, MEMORYID, CLUSTR,  CLUSID. And the remaining fields can be anything.
    2. Enable the Save button in the Function keys part of GUI Status. And Add a push button for Get variant.
    3. When Save button clicked call a screen with a single field for variant (let us say g_var). After g_var entered, in the PAI of the initial screen export all the screen values to the created database index using the statement .
                         EXPORT: g_characteristics_tab TO DATABASE zav0257(ch) ID g_var,
                                       s_auart TO DATABASE zav0257(au) ID g_var.
                         So that the values will be exported to database.
                         Then update the fields(VARI_NAME,PROG_NAME,UNAME) of  the database table using modify from work area. 
                         So that you will have the history of variance existence.
    4. Next time , when the user clicks on Get Variant option, call another screen to enter the variant name. Then import the values for that variant from the memory id in the database table.
    It worked for me.

  • How to add logo in module pool screen

    Hi Expert,
    I need to display company logo in the module pool screen
    how this can be added ?
    Regards
    Bikas

    Hi,
    create a custom control called 'CUSTOM_CONTROL'
    CONSTANTS: CNTL_TRUE  TYPE I VALUE 1,
          CNTL_FALSE type i value 0.
    data:h_picture       type ref to cl_gui_picture,
         h_pic_container type ref to cl_gui_custom_container.
    data: graphic_url(255),
          graphic_refresh(1),
          g_result like cntl_true.
    data: begin of graphic_table occurs 0,
            line(255) type x,
          end of graphic_table.
    data: graphic_size type i.
    data: g_stxbmaps type STXBITMAPS,
          l_bytecnt  type i,
          l_content   TYPE  standard table of bapiconten initial size 0.
    g_stxbmaps-tdobject = 'GRAPHICS'.
    g_stxbmaps-tdname = 'ENJOY'.
    g_stxbmaps-tdid = 'BMAP'.
    g_stxbmaps-tdbtype = 'BMON'. 
    call function 'SAPSCRIPT_GET_GRAPHIC_BDS'
         exporting
              i_object       = g_stxbmaps-tdobject
              i_name         = g_stxbmaps-tdname
              i_id           = g_stxbmaps-tdid
              i_btype        = g_stxbmaps-tdbtype
         importing
              e_bytecount    = l_bytecnt
         tables
              content        = l_content
         exceptions
              not_found      = 1
              bds_get_failed = 2
              bds_no_content = 3
              others         = 4.
    call function 'SAPSCRIPT_CONVERT_BITMAP'
         exporting
              old_format               = 'BDS'
              new_format               = 'BMP'
              bitmap_file_bytecount_in = l_bytecnt
         importing
              bitmap_file_bytecount  = graphic_size
         tables
              bds_bitmap_file        = l_content
              bitmap_file            = graphic_table
         exceptions
              others                 = 1.
    call function 'DP_CREATE_URL'
         exporting
            type                 = 'image'           
            subtype              = cndp_sap_tab_unknown
            size                 = graphic_size
            lifetime             = cndp_lifetime_transaction
         tables
            data                 = graphic_table
         changing
            url                  = graphic_url
         exceptions
            others               = 4 .
    create object h_pic_container
           exporting container_name =  'CUSTOM_CONTROL'.
    create object h_picture exporting parent = h_pic_container.
    call method h_picture->set_display_mode
         exporting
              display_mode = cl_gui_picture=>display_mode_normal.
    call method h_picture->load_picture_from_url
         exporting url    = graphic_url
         importing result = g_result.
    or you can check the program RSDEMO_CUSTOM_CONTROL
    check link :
    How to insert Image on Screen
    thanks
    Parvathi

Maybe you are looking for

  • Data rate supported by 6533

    Hello, Can someone tell me what is the data rate supported by PCI 6533. i mean transfer the data from peripheral to the hard disk of the PC.

  • [SOLVED]"permission denied" when building pkg

    most consistantly, I get the error when a pkgbuild has the line: ./autogen.sh in building linphone-git, mediastreamer-git and ortp-git another time, I got burned with the line: ./system.tmp from building wiimms-iso-tools and the last pkg I tried to b

  • Trying to assign refference pernr

    I am on ERP 2004 without concurrent employement or Global Employee Management implemented. I have a single employee with a pernr in US and a pernr in Canada. I am trying to assign a reference pernr to each so they will be linked in HRP1001 by a centr

  • HT4718 An error. Occurs while trying to run this installations

    I Have bought a second hand MacBook Air from a friend, we have been unable to re install maverick o sx, an error occurs during the verification process. any advice?

  • Comment acheter une application au mexique avec un compte du canada

    Bonjour Apple, j'ai un problème avec des cartes itunes. J'ai acheter au Mexique trois cartes itunes: 2 de 600 pesos et 1 de 300 pesos. Quand je suis arriver je suis arriver pour entrer le code il mon dit que le code devait être utiliser dans un store