Can a server process be assigned fixed (Logos) port?

Hi, This question relates to protecting logos traffic between a web client and a server process. We have a number of internet users accessing their own server processes on a single server machine. We would like to set up multiple VPNs for each server process so that users cannot interact with others server processes. However, because each server process is dynamically assiged a port by Logos at startup we cannot do this. Does anyone know if it is possible to set a predetermined port for each process via logos or are there any other alternatives to secure the traffic? Thanks

TRL,
OK...I missed that part .
Lookout does implement a "network security layer" that provides access privileges to each process, object and subfolders. Its drawback is the "lookout.sec" file, you have to copy it manually (or get it copied) to each client computer.
Also, there are some default settings you should change in order to get it working.
First: create a good lookout.sec file.
Give the Administrator account a password(by default it doesn't have one) and be sure it is not the default login user.
Create as many users (or groups of users) as you need (maybe one per process) using the User Manager. After doing that you can distribute "lookout.sec".
Second: Set network security properties to each process.
Open the "Network Securi
ty Properties" window by rigth clicking (in the object explorer) over the process you want to restrict access and left-click "Configure Network Security". Push "Permission..." button and select the user want to allow or restrict access.
Refer to chapter 10 Security to get more information about the available options.
Hope it works for you
JSS

Similar Messages

  • I installed OSX server 10.6 snow leopard on my IMAC, but still have choppy videos. can anyone tell me how to fix the problem

    I installed OSX server 10.6 snow leopard on my IMAC, but still have choppy videos. can anyone tell me how to fix the problem

    By your use of "still", did this problem exist before OS X Server was installed?  OS X Server itself has no particular linkages to video processing, beyond what OS X client provides.
    Some details on the configuration might be useful.  Are these videos you're having issues with stored locally in files, or are these videos received over the network and played?  If the videos are local, have you tried playing the videos from a different disk?  If the video files are remote, can you download the videos and play them as a test?
    What software are you using to play the videos?  QuickTime?  QuickTime X?  Does using VLC or another player work better?  There are some discussions of choppy videos around the forums, too.

  • I have a macbook and when I power it on and then select myself as a user...It won't power up. It stays in the white screen with the apple logo. I am online currently under 'guest user'. Is there anything I can do from the keyboard to fix this??? Help!!!

    I have a macbook and when I power it on and then select myself as a user...It won't power up. It stays in the white screen with the apple logo. I am online currently under 'guest user'. Is there anything I can do from the keyboard to fix this??? Help!!!

    Could you specify the model of MacBook and the OS X it's running, please? Some of the advice or references vary along with the system, so this could be helpful to formulate a reply. I've never used a Guest User selection, but do have more than one User.
    If the computer does not have an optical drive, you may be able to boot it into a recovery disk mode or something; in an attempt to see what is wrong and maybe fix it.
    Good luck & happy computing!

  • I have mac osx 10.6.8 and I keep getting update notices that do nothing, just search for update server. Happens every day. What can you or I do to fix this?

    I have mac osx 10.6.8 and I keep getting update notices that do nothing, just search for update server. Happens every day. What can you or I do to fix this? Other people I work with and use macs have the same issue.

    If you have problems with updating or with the permissions then easiest is to download the full version and trash the currently installed version to do a clean install of the new version.
    Download a new copy of the Firefox program and save the DMG file to the desktop
    * Firefox 6.0.x: http://www.mozilla.com/en-US/firefox/all.html
    * Trash the current Firefox application to do a clean (re-)install
    * Install the new version that you have downloaded
    Your profile data is stored elsewhere in the Firefox Profile Folder, so you won't lose your bookmarks and other personal data.
    * http://kb.mozillazine.org/Profile_folder_-_Firefox

  • Can I find out how many clients are connected to a server process?

    Hi, I am hoping I can find out how many clients are connected to a server process. This could be either a programmatic lookout number, a number in a log file etc.
    By the way, does lookout have any application (not data) logs? I have noticed that occasionally lookout will crash and I cannot find any logs to determine why, what processes were running, who last accessed it etc.
    Thanks

    Hello,
    There's currently no way to acquire this data. I think that'd be a great suggestion for the product. Please submit your feedback to our developers at the following link: http://digital.ni.com/applications/psc.nsf/default?OpenForm&temp1=&node=
    Best regards,
    Yusuf C
    Application Engineer
    National Instruments

  • When spanning new tabs (firefox) my users are asked to re-authenticate with pages already signed into. Can you tell me how to fix this issue for firefox users?

    With some research I found regedit setting called “TabProcGrowth” that allows tabs to span without re-authenticating with certain browsers. Can you tell me how to fix this issue for my Mozilla Firefox users? Our current version of Mozilla Firefox is: 24.5.0 (x86 en-US). This was first noticed with a product called Confluence that we use in our Tech Support area. Users are having to reenter their password every time they click on a new link in confluence. Any help would be appreciated.
    Thank you,

    Hi Bernie:
    As long as you are accessing your internal server on http:// or https:// then I would expect the normal rules to apply. To see whether some external requests are being blocked, you might try using Firefox's Web Console, Network tab.
    You can open the console in the lower part of a tab using either:
    * Ctrl+Shift+k
    * "3-bar" menu button > Developer > Web Console
    * (menu bar) Tools menu > Web Developer > Web Console
    Click "Network" on the top bar of the Web Console.
    Then use the address bar or a bookmark to launch Confluence in the same tab. Each request made by Firefox should be displayed along with the result. You can click a row for more details.
    When I look up "TabProcGrowth" it seems related to the Protected Mode feature of IE8 and newer, which is not (yet) applicable to Firefox. http://blogs.msdn.com/b/askie/archive/2009/03/09/opening-a-new-tab-may-launch-a-new-process-with-internet-explorer-8-0.aspx
    However, if Confluence is heavily reliant on plugins such as Flash or Java, that could be a factor because plugins are run out-of-process in Firefox. In that case I suggest checking with Confluence for suggestions.

  • Configure server process

    Dear All,
    We are in the process of upgrading oracle applciation r11.5.10.2 to  r 12.1.3 , 12.1 upgrade is about to complete,
    a) can I upgrade to R12.1.3 with all latest RPC and patch fixes, and then configure "Configure and start server processes using rapidwiz"?. or I have to do this after upgrading to R12.1.1
    b) in the above scenario, if I configure server process after upgrade to r12.1.3, then can I upgrade OAS to 10.1.3.5 later ?
    c) Do I have to run rapid wiz (configure server process) as root user or app tier user?
    Please advise

    a) can I upgrade to R12.1.3 with all latest RPC and patch fixes, and then configure "Configure and start server processes using rapidwiz"?. or I have to do this after upgrading to R12.1.1
    You have to apply those patches after you configure and start the server processes.
    b) in the above scenario, if I configure server process after upgrade to r12.1.3, then can I upgrade OAS to 10.1.3.5 later ?
    Yes.
    c) Do I have to run rapid wiz (configure server process) as root user or app tier user?
    As root user if you are using (applmgr and oracle) users to maintain the application and database tier node files. If only one user maintains all application/database tier nodes files then run Rapid Install as that user -- Just run Rapid Install as you did when you had to lay down R12 software.
    Thanks,
    Hussein

  • Directing requests to a particular server process

    Hi
    If I have two Server process connected to a single Java dispacther how can I force my web dynpro application to be run from one or the other .
    I am aware that the J2EE Engine uses cookies to register a request with a particular server process and thus by which dedicate all requests with specific cookie information to specific server processes.
    Is there a way to provide dispatcher+server instance details in a URL and thus forcing a particular server process to service this request.
    Regards
    Pran

    Hi,
    Sorry to say but all servers which are member of same RD Farm name are expected to have access of all application installed. We cannot control which specific server in a RD Farm a user is directed to. Still we can configure RemoteApp under RDSH server and assign
    the user to connect to the specific RemoteApp by assigning RemoteApp User Assignment.
    By this way, suppose we install WordPad as RemoteApp on RDSH server 1 and Notepad as RemoteApp on RDSH server 2 then provide the access to the specific user to access that RemoteApp under user assignment and don’t allow under other App so that specific user
    can only access the assigned RemoteApp.
    Anyway for redirection of server is managed by RDCB and there are different ways now to handle such as DNS RR, NLB, Hardware Load balancer or Dedicated Farm redirection and it depends on you what you prefer for your environment.
    More detail.
    Introducing RemoteApp User Assignment
    http://blogs.msdn.com/b/rds/archive/2009/06/12/introducing-remoteapp-user-assignment.aspx
    Hope it helps!
    Thanks.
    Dharmesh Solanki
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Support, contact [email protected]

  • ORA-12500 TNSLISTENER failed to start a dedicated server process

    Environment W2000 Pro SP4 latest fixes
    I just installed database 10g (10.1.0) in order to have a 10g (10.1) database (ORCL1) as required by Oracle Warehouse builder and other business intelligrence products like disoverer (from discoverer suite) and Portal 10g (9.0.4)
    during installation of 10g database I got following messages
    ==>Oracle Cluster Registry failed to initialize (in french) and went on
    ==>error when starting OracleCsservice
    i retried and went on.
    Install finishes correctly
    I can access the new database (type warehouse) with sqlplus in a dos window
    However I can't reach it through SQL*Plus of oracle 10g database and get ORA-12500 TNSLISTENER failed to start a dedicated server process message
    OracleCSService starting
    OracleDBConsoleORCL1 started
    OracleINFRASControl started
    OracleINFRAprocessManager started
    OracleINFRATNSListener started
    OracleOraDb10g_home1iSQL*Plus Started
    OraclePORTALBIASontrol Started
    OraclePORTALBIProcessManager Started
    OracleServiceASDB Started
    OracleServiceORCL1 Started
    ...... other databases.....
    I only have one LISTENER service (the one that was created for INFRAstructure instance) is it OK ?
    All other databases instances I am using where created from INFRA DBCA. and all defined with a dedicated server.
    I tried to define it through DBCA of Oracle database
    left dedicated server and finish
    won't work DBCA refuses
    I also tried to Stop/start OracleServiceOrcl1 but it won't stop
    database ORCL1 is unreachable from other instances:
    from Oracle WareHouse Builder's Enterprise Manager console I get the same ORA-12500 message
    same with Oracle Net Configuration Assistant of
    Oracle Developer Suite Net assistant
    What's wrong,
    is one listener enough? is there a bug in the product?..
    I read quite a few enties but didnt get the answer to my problem

    Hello Werner,
    What means error 1058?
    i posted an entry in application server
    Listener.ora and tsnames .ora where updated on INFRAstructure instance to be nearly identical to 10g DB instance (diference is one db definition)
    However starting infrastructure and portal instances has become erratic and error prone:u
    It takes about 20 minutes to start these two instances by hand has before i had only to start them and everything went smoothly (but took also a long time).
    Now i get the following messages and have to use following opmnctl commands to have the whole thing running as follows:
    ==> start INFRASTRUCTURE
    lancement de tnslsnr: veuillez patientez...
    failed to start service, error 1058 ==> new message
    TNS-12536: l'opération provoquerait le blocage ==>new
    TNS-12560 erreur d'adaptateur de protocole ==> not new and didn(t care
    TNS-00506 l'opération provoquerait un blocage ==> new
    32-bits Windows Error: 997: Unknown error ==>not new and didn't care
    I also get from SMTP the following mail:
    Nom=LISTENER_ternes-1-81-57-68-1.fbx.proxad.net
    Type=Listener
    Hôte=ternes-1-81-57-68-1.fbx.proxad.net
    Mesure=Status
    Horodatage=2 nov. 2004 23 h 34 CET
    Gravité=Critique
    Message=The listener is down: TNS-12541: TNS:no listener .
    Nom de la règle=Listener Availability
    Propriétaire de la règle=SYSMAN
    1-opmnctl status
    opmnctl status
    IAS-component process-type pid status
    OID OID N/A Down
    OC4J OC4J_SECURITY N/A Down
    HTTP_Server HTPP_Server 1588 Alive
    dsm-daemon dcm-daemon N/A Down
    LogLoader logloaderd N/A Down
    here its very erratic sometimes OID is in STOP status
    2-opmnctl startall
    opmnctl status
    opmnctl status
    IAS-component process-type pid status
    OID OID 3504 Alive
    OC4J OC4J_SECURITY 3416 Alive
    HTTP_Server HTPP_Server 1588 Alive
    dsm-daemon dcm-daemon N/A Down
    LogLoader logloaderd N/A Down
    3_opmnctl startproc ias-component=dcm-daemon
    opmnctl status
    IAS-component process-type pid status
    OID OID 3504 Alive
    OC4J OC4J_SECURITY 3416 Alive
    HTTP_Server HTPP_Server 1588 Alive
    dsm-daemon dcm-daemon 5524 Alive
    LogLoader logloaderd N/A Down
    At that point i can start Portal instance
    Processes in Instance: PORTALBI.ternes-1-81-57-68-1.fbx.proxad.net
    ----------------------------------------------+---------
    ias-component | process-type | pid | status
    ----------------------------------------------+---------
    wireless | OC4J_Wireless | 5292 | Alive
    wireless | messaging_server | 3456 | Alive
    wireless | performance_server | 1364 | Alive
    Discoverer | PreferenceServer | 2080 | Alive
    Discoverer | OAD | 2124 | Alive
    Discoverer | OSAgent | 1688 | Alive
    OC4J | OC4J_WSRP | 820 | Alive
    OC4J | OC4J_Portal | 4264 | Alive
    OC4J | OC4J_BI_Forms | 5020 | Alive
    OC4J | home | 4948 | Alive
    WebCache | WebCacheAdmin | 1976 | Alive
    WebCache | WebCache | 3500 | Alive
    HTTP_Server | HTTP_Server | 1912 | Alive
    dcm-daemon | dcm-daemon | 5048 | Alive
    LogLoader | logloaderd | N/A | Down

  • Can web server plugin point to multiple cluster ?

    Hi,
              Can you point a web server plugin to multiple Weblogic 8.1 clusters ? If yes, how does the dynamic list work ?
              E.g. Web server X -> Cluster Y & Cluster Z
              In the plugin documentation it is not explicit that you can or can't do so (http://edocs.bea.com/wls/docs81/plugins/plugin_params.html#1149781).
              "WebLogicCluster : List of WebLogic Servers that can be used for load balancing. The server or cluster list is a list of host:port entries. If a mixed set of clusters and unclustered servers is specified, the dynamic list returned for this parameter will return only the clustered servers."
              Thanks,
              Antonio Goncalves

    you need to introduce a 'NameTrans' directive to redirect the url that you want to send to the back end
    for example, edit your obj.conf to look like
    <Object name="default">
    NameTrans fn="assign-name" name="passthrough" from="<give a top level url that you want to send to the back end"
    and restart the server.
    disabling java will reduce the web server process size significantly. unfortunately, this is a very manual process in 6.1. however, if you could consider migrating to web server 7 u2, where reverse proxy plugin is integrated within the produce (rather than as a separate plugin), u could easily disable-java and configure reverse proxy through either gui or cli command
    http://docs.sun.com/app/docs/doc/820-2204/disable-java-1?a=view
    http://docs.sun.com/app/docs/doc/820-2204/create-reverse-proxy-1?a=view
    pl. remember to run a deploy-config as soon as you run each of this above command. again, this would be relevant only if want to upgrade to web server 7

  • How do Server process and cliend process communicate ?

    Hi
    When a client session is started, the client contacts the listener (running on a port - 1521, let us say).The listener creates a Server process to server the client.
    Now how do the client process and the server process communicate. I mean does the server process run on a seperate por( Just as the listener runs on a specific port).
    Can someone plese clarify.
    Thanks,
    Prasad

    Have a look at this note:
    Oracle Connections and Firewalls [ID 125021.1]
    When the Oracle client makes a connection to the database e.g. (sqlplus userid/password@alias), it compares the alias name supplied in the sqlplus line and looks for a match in the TNSNAMES.ORA file or Names server. Once it obtains the address for the database server, a connection attempt is made to the server from the client. The Listener is contacted on the database server and port redirection can take place depending on the platform, configuration of the INIT<SID>.ORA file and/or the Oracle product being used. The underlying network layer on the server will obtain a free port from the Operating System (OS) and send back to the client via the Listener the new port assignment. The client will then try to connect to the database on a new port. This is where connection failure normally occurs.
    A remote Oracle client making a connection to an Oracle database can fail if there is a firewall installed between the client and the server and if port redirection is taking place. The firewall will block the connection to the new port when the Oracle client connects to the database - the client typically fails with Oracle errors ORA-12203 or ORA-12535. The client connection failure is due to port redirection from the Database Server's operating system. Port redirection requires the client to connect to the database using a different port than originally configured in the configuration files. Oracle Multi-Threaded Server (MTS) on Unix platforms, (without specifying the address with the ports in the INIT<SID>.ORA file), Oracle Secure Sockets Layer (SSL) and Windows NT/2000 platforms will cause port redirection.
    ...

  • Managing server process ports

    Hello,
    I have some questions about ports used by oracle server processes.
    Supoose we have listener on 1521
    1. Dedicated server: when client connects to the database the listener spawns new process which is also using 1521 (port sharing), right? And if there's another client connecting to the db, and listener spawns another server process, it's also using 1521?
    2. Shared server process. We define 4 dispatchers for example.. Are they all using the same port? For example
    dispatchers=(address=(protocol=TCP)(Host=myhost)(PORT=1561)(dispatchers=4)"
    does it mean all 4 dispatchers are accessible on 1561 ports? What about shared server processes then? If we define shared_server=3 for example, on which port numbers are they listening?
    Thanks in advance for help,
    Aliq

    Aliq,
    You need to check whether you are using port redirection.
    You can do that by running netstat -a, or by tracing sqlnet (on level 16)
    The word 'redirect' will be in your trace file.
    The best solution to use one port, is to install Oracle Connection Manager, using a custom install, and to set up all connections for Oracle Connection Manager. You now have
    server client
    session -------(random port) connection manager----fixed port session
    You can misuse shared server for this purpose but you are risking to open extra ports as the number of sessions increases.
    Used_shared_sockets will result in a disconnect of all sessions, when you stop the listener. Not a good idea
    2
    If you hardcode a portnumber for the first dispatcher (and using CMAN you don't need to anymore), subsequent dispatchers will just use the first free port. This may be in your case 1562, or 1566, or ... who knows?
    Hth
    Sybrand Bakker
    Senior Oracle DBA

  • Assign fixed values through CMOD

    Hello all,
    I have been asked to make an enhancemet to assing fixed values to a field, so there would be a drop down after wards. Is this posible through CMOD? I know i can do it through se11 and fix the domain, but not sure if it is the correct process.
    Thanks.

    Hi,
    Enhancement(SMOD,CMOD) or BADI (SE18,SE19) are just predefined user exit for customer to implement their specific logic in the specific application/component .
    So your question is depending on whether there is a prefined user exit for that field. In my opinion, enhancement for assigning fiexed values to field mostly don't have predefined user exit.
    But you can achieve it with it's search help exit instead, do as below:
    1. If  a search help already been attached to that field, just implement search help exit via se11(choose search help and change)
    Hope helps,
    Chen Jian

  • Application Server (Process Scheduler) Not Booting

    Hello to all!
    Having a quite difficult time booting the App. Server. Not sure what is going on? Not to my knowledge has anything changed to make the App. Server not boot this time. Probably a clinch, but still want to share my frustration. I presently run an Oracle 10g DB, PeopleSoft 8.50, Windows 7 Ulimate PC and here's what I am experiencing (see below):
    Microsoft Windows [Version 6.1.7601]
    Copyright (c) 2009 Microsoft Corporation. All rights reserved.
    C:\Users\afam>cd\
    C:\>cd pt8.50\appserv
    C:\PT8.50\appserv>psadmin
    PSADMIN -- Tools Release: 8.50.14
    Copyright (c) 1988, 2009, Oracle. All rights reserved.
    PeopleSoft Server Administration
    1) Application Server
    2) Process Scheduler
    3) Search Server
    4) Service Setup
    q) Quit
    Command to execute (1-4, q): 1
    PeopleSoft Application Server Administration
    1) Administer a domain
    2) Create a domain
    3) Delete a domain
    4) Import domain configuration
    q) Quit
    Command to execute (1-4, q) : 1
    Tuxedo domain list:
    1) INNOVATI
    Select domain number to administer: 1
    PeopleSoft Domain Administration
    Domain Name: INNOVATI
    1) Boot this domain
    2) Domain shutdown menu
    3) Domain status menu
    4) Configure this domain
    5) TUXEDO command line (tmadmin)
    6) Edit configuration/log files menu
    7) Messaging Server Administration menu
    8) Purge Cache
    9) Preload File Cache
    10) Clean IPC resources of this domain
    q) Quit
    Command to execute (1-10, q) : 1
    PeopleSoft Domain Boot Menu
    Domain Name: INNOVATI
    1) Boot (Serial Boot)
    2) Parallel Boot
    q) Quit
    Command to execute (1-2, q) [q]: 1
    Attempting to boot bulletin board...
    tmadmin - Copyright (c) 2007-2008 Oracle.
    Portions * Copyright 1986-1997 RSA Data Security, Inc.
    All Rights Reserved.
    Distributed under license by Oracle.
    Tuxedo is a registered trademark.
    No bulletin board exists. Entering boot mode.
    INFO: Oracle Tuxedo, Version 10.3.0.0 with VS2005, 32-bit, Patch Level (none)Booting admin processes ...
    exec BBL -A :
    process id=8068 ... Started.
    1 process started.
    Attaching to active bulletin board.
    Attempting to boot ...INFO: Oracle Tuxedo, Version 10.3.0.0 with VS2005, 32-bit, Patch Level (none)
    Booting server processes ...
    exec PSWATCHSRV -o ".\LOGS\stdout" -e ".\LOGS\stderr" -A -- -ID 49520 -D INNOVAT
    I -S PSWATCHSRV :
    process id=6852 ... Started.
    exec PSAPPSRV -o ".\LOGS\stdout" -e ".\LOGS\stderr" [email protected] -- -D INNOVA
    TI -S PSAPPSRV :
    CMDTUX_CAT:1685: ERROR: Application initialization failure
    tmboot: CMDTUX_CAT:827: ERROR: Fatal error encountered; initiating user error ha
    ndler
    tmshutdown -qy
    ==============ERROR!================
    Boot attempt encountered errors!. Check the TUXEDO log for details.
    ==============ERROR!================
    Do you wish to see the error messages in the APPSRV.LOG file? (y/n) [n] :y
    PSADMIN.7352 (0) [12/17/12 21:00:02](0) Begin boot attempt on domain INNOVATI
    PSAPPSRV.4832 (0) [12/17/12 21:00:13](0) PeopleTools Release 8.50.14 (WinX86) st
    arting. Tuxedo server is APPSRV(99)/2
    PSAPPSRV.4832 (0) [12/17/12 21:00:14](0) Cache Directory being used: C:\PT8.50\a
    ppserv\appserv\INNOVATI\CACHE\PSAPPSRV_2\
    PSAPPSRV.4832 (0) [12/17/12 21:00:14](3) File: SQL Access ManagerSQL error. Stmt
    #: 2 Error Position: 0 Return: 1033 - ORA-01033: ORACLE initialization or shu
    tdown in progress
    PSAPPSRV.4832 (0) [12/17/12 21:00:14](1) GenMessageBox(200, 0, M): SQL Access Ma
    nager: File: SQL Access ManagerSQL error. Stmt #: 2 Error Position: 0 Return:
    1033 - ORA-01033: ORACLE initialization or shutdown in progress
    PSAPPSRV.4832 (0) [12/17/12 21:00:14](1) GenMessageBox(0, 0, M): Database Signon
    : Could not sign on to database INNOVATI with user PS.
    PSAPPSRV.4832 (0) [12/17/12 21:00:14](0) Server failed to start
    PSADMIN.7352 (0) [12/17/12 21:00:21](0) End boot attempt on domain INNOVATI
    Do you wish to see the error messages in the TUXLOG.121712 file? (y/n) [n] :y
    210002.KELVIN!PSADMIN.7352: Begin attempt on domain INNOVATI
    210006.KELVIN!tmadmin.7744.5444.-2: TMADMIN_CAT:1330: INFO: Command: boot -A
    210008.KELVIN!tmboot.7652.7332.-2: 12-17-2012: Tuxedo Version 10.3.0.0 with VS20
    05, 32-bit
    210008.KELVIN!tmboot.7652.7332.-2: CMDTUX_CAT:1851: INFO: TM_BOOTTIMEOUT is set
    to 120 seconds
    210008.KELVIN!tmboot.7652.7332.-2: CMDTUX_CAT:1855: INFO: TM_BOOTPRESUMEDFAIL op
    tion is selected
    210010.KELVIN!BBL.8068.7320.0: 12-17-2012: Tuxedo Version 10.3.0.0 with VS2005,
    32-bit, Patch Level (none)
    210010.KELVIN!BBL.8068.7320.0: LIBTUX_CAT:262: INFO: Standard main starting
    210012.KELVIN!tmboot.7248.3440.-2: 12-17-2012: Tuxedo Version 10.3.0.0 with VS20
    05, 32-bit
    210012.KELVIN!tmboot.7248.3440.-2: CMDTUX_CAT:1851: INFO: TM_BOOTTIMEOUT is set
    to 120 seconds
    210012.KELVIN!tmboot.7248.3440.-2: CMDTUX_CAT:1855: INFO: TM_BOOTPRESUMEDFAIL op
    tion is selected
    210012.KELVIN!PSWATCHSRV.6852.4148.-2: 12-17-2012: Tuxedo Version 10.3.0.0 with
    VS2005, 32-bit
    210012.KELVIN!PSWATCHSRV.6852.4148.-2: LIBTUX_CAT:262: INFO: Standard main start
    ing
    210013.KELVIN!PSAPPSRV.4832.4956.0: 12-17-2012: Tuxedo Version 10.3.0.0 with VS2
    005, 32-bit
    210013.KELVIN!PSAPPSRV.4832.4956.0: LIBTUX_CAT:262: INFO: Standard main starting
    210014.KELVIN!PSAPPSRV.4832.4956.0: LIBTUX_CAT:250: ERROR: tpsvrinit() failed
    210014.KELVIN!tmboot.7248.3440.-2: tmboot: CMDTUX_CAT:827: ERROR: Fatal error en
    countered; initiating user error handler
    210018.KELVIN!BBL.8068.7320.0: CMDTUX_CAT:26: INFO: The BBL is exiting system
    210021.KELVIN!PSADMIN.7352: End boot attempt on domain INNOVATI
    Press Enter to continue...
    PeopleSoft Domain Administration
    Domain Name: INNOVATI
    1) Boot this domain
    2) Domain shutdown menu
    3) Domain status menu
    4) Configure this domain
    5) TUXEDO command line (tmadmin)
    6) Edit configuration/log files menu
    7) Messaging Server Administration menu
    8) Purge Cache
    9) Preload File Cache
    10) Clean IPC resources of this domain
    q) Quit
    Command to execute (1-10, q) :
    Any help would be greatly appreciated! Thanks. Be Blessed

    Herald:
    Thanks for getting back to me! I think you are right in that this would be a question more geared toward to the Peoplesoft folks. The post is there, so thank you for that. However, you noted a key observation that led me to want to investigate more. If we look at a past post that speaks to your observation (ORACLE Initialization or shutdown in progress I believe it gave me more clues to go by. I do shared the same thought as the poster in that, the DB should have started as the service started for the DB as already. At any rate, I ran the instructed command in SQL, I got this script:
    Microsoft Windows [Version 6.1.7601]
    Copyright (c) 2009 Microsoft Corporation. All rights reserved.
    C:\Users\afam>cd\
    C:\>sqlplus/nolog
    SQL*Plus: Release 10.2.0.1.0 - Production on Tue Dec 18 05:36:02 2012
    Copyright (c) 1982, 2005, Oracle. All rights reserved.
    SQL> connect sys/manager as sysdba
    Connected.
    SQL> shutdown immediate
    ORA-01109: database not open
    Database dismounted.
    ORACLE instance shut down.
    SQL> startup
    ORA-32004: obsolete and/or deprecated parameter(s) specified
    ORACLE instance started.
    Total System Global Area 293601280 bytes
    Fixed Size 1248600 bytes
    Variable Size 83886760 bytes
    Database Buffers 201326592 bytes
    Redo Buffers 7139328 bytes
    Database mounted.
    ORA-16038: log 1 sequence# 1337 cannot be archived
    ORA-19809: limit exceeded for recovery files
    ORA-00312: online log 1 thread 1:
    'C:\ORACLE\PRODUCT\10.2.0\ORADATA\INNOVATI\REDO01.LOG'
    SQL>
    What can be made from this observation? Be Blessed

  • Question regarding Listener and Server Processes in dedicated server mode

    Good morning,
    The Oracle documentation states that when a client connection request is received on the server, the Listener creates a Server Process which will work with the database instance to carry out the tasks requested by the user/client process. So far, everything good.
    Now, when the user is at the Oracle server itself, the Listener does not need to be running to establish a connection to the database. It is therefore possible to stop the Listener and still connect using sqlplus and a valid username and password.
    In the above case, the question is: if the Listener is not running, what/who created the Server Process that communicates with the database instance on behalf of the user ? Stated a different way, in the normal case, the Listener would get the request and create the server process. When the Listener is not running what part of Oracle gets the requests and creates the server process ?
    Clarification on how this case is handled is much appreciated, thank you,
    John.

    When using bequeath protocol the server process is created by the client process: it's the client process that is using ORACLE_SID and ORACLE_HOME to compute shared memory key (under UNIX) to know which SGA to attach (i.e. which instance to connect to):
    Example with SQL*Plus :
    $ ps -fu oracle | grep DB112
    oracle    5675     1  0 18:13 ?        00:00:00 ora_pmon_DB112
    oracle    5677     1  3 18:13 ?        00:00:02 ora_vktm_DB112
    oracle    5681     1  0 18:13 ?        00:00:00 ora_gen0_DB112
    oracle    5683     1  0 18:13 ?        00:00:00 ora_diag_DB112
    oracle    5685     1  0 18:13 ?        00:00:00 ora_dbrm_DB112
    oracle    5687     1  0 18:13 ?        00:00:00 ora_psp0_DB112
    oracle    5689     1  0 18:13 ?        00:00:00 ora_dia0_DB112
    oracle    5691     1  0 18:13 ?        00:00:00 ora_mman_DB112
    oracle    5693     1  0 18:13 ?        00:00:00 ora_dbw0_DB112
    oracle    5695     1  0 18:13 ?        00:00:00 ora_lgwr_DB112
    oracle    5697     1  0 18:13 ?        00:00:00 ora_ckpt_DB112
    oracle    5699     1  0 18:13 ?        00:00:00 ora_smon_DB112
    oracle    5701     1  0 18:13 ?        00:00:00 ora_reco_DB112
    oracle    5703     1  0 18:13 ?        00:00:00 ora_mmon_DB112
    oracle    5705     1  0 18:13 ?        00:00:00 ora_mmnl_DB112
    oracle    5707     1  0 18:13 ?        00:00:00 ora_d000_DB112
    oracle    5709     1  0 18:13 ?        00:00:00 ora_s000_DB112
    oracle    5745     1  0 18:13 ?        00:00:00 ora_arc0_DB112
    oracle    5747     1  0 18:13 ?        00:00:00 ora_arc1_DB112
    oracle    5749     1  0 18:13 ?        00:00:00 ora_arc2_DB112
    oracle    5751     1  0 18:13 ?        00:00:00 ora_arc3_DB112
    oracle    5753     1  0 18:13 ?        00:00:00 ora_qmnc_DB112
    oracle    5769     1  1 18:13 ?        00:00:00 ora_cjq0_DB112
    oracle    5773     1  0 18:13 ?        00:00:00 ora_q000_DB112
    oracle    5775     1  0 18:13 ?        00:00:00 ora_q001_DB112
    oracle    5777     1  1 18:13 ?        00:00:00 ora_vkrm_DB112
    oracle    5785     1 46 18:13 ?        00:00:24 ora_j003_DB112
    oracle    5797  5796  2 18:14 ?        00:00:00 oracleDB112 (DESCRIPTION=(LOCAL=YES)(ADDRESS=(PROTOCOL=beq)))
    oracle    5832  5801  0 18:14 pts/2    00:00:00 grep DB112
    $ ps -fp 5796
    UID        PID  PPID  C STIME TTY          TIME CMD
    oracle    5796  5584  0 18:14 pts/1    00:00:00 sqlplusThis is also documented in 11.2 Net Admin. Guide http://download.oracle.com/docs/cd/E11882_01/network.112/e10836/concepts.htm#CIAFHAEE
    >
    If the client and database exist on the same computer, then a client connection can be passed directly to a dedicated server process without going through the listener. This is known as a bequeath protocol. The application initiating the session spawns a dedicated server process for the connection request. This happens automatically if the application used to start the database is on the same computer as the database.
    >
    Edited by: P. Forstmann on 5 sept. 2010 18:23

Maybe you are looking for

  • How to Suppress the POP UP window for Print out Device

    Hi All, I have One ALV Grid report and in this report I want to SUBMIT another report which, when executes gives the POP UP window for Printer Device and sends the output to that device. if we give LOCL, sends output to Spool. So I want to Suppress t

  • A/P Down Payment Request Error

    Dear Experts, I am getting an error while entering Down Payment Request, i.e. "Down payment payable/receivable account was not defined". Help Required, Thanks

  • How to determine the background job status?

    Hi Gurus, My program is as follows: 1. I have used FM job_open to open a new job. 2. SUBMIT to call another program which creates the file on application server. 3. FM job_close to trigger that job. Now I want to determine the status of that triggere

  • Can't backup my phone

    I have 8.6 GB of "other". I don't understand why I have so much because I only have apps, music and pictures on my phone. I decided to restore my phone but first I have to do a backup. I plugged my phone into iTunes to back it up but I couldn't find

  • Can't get flash to work in firefox

    On I. E. the flash movie works fine but when it is tried in firefox it doesn't appear. A right click of the mouse shows that the flash is there but it doesn't work. Is there something that has to be added or removed in order to make this work properl