Can I use labview 7.1 run time in windows 98?

I am going on update a too old test system. I use labview 7.1,but I find I can't install labview 7.1 runtime in windows 98.
so should I use labview 6.1 instead of it?
Sonic
Diffrent Strokes for Different Folks

Why cnt you update both ?!
- Partha
LabVIEW - Wires that catch bugs!

Similar Messages

  • Why is VI not executable using Labview 7.1 Run-Time Engine?

    Hi,
    In our Teststand sequence, we have a Labview Action step which is returning an error: "The VI is not executable", along with the error code: -18002.
    This error occurs on a Production PC using the L.V. 7.1 Run-Time Engine.
    I'm aware of Mass Compiling to ensure all the VI's are the correct version, but this has not resolved the problem.
    The software was installed on the production PC using a Teststand created installer, with the Labview Adapter set
    correctly to the Run-Time Engine, i.e. not trying to open the Labview Developer Server to execute the step at run time.
    Because it's the 1st Labview module to be executed, I added another similar step to run beforehand, i.e. the new simple
    Labview code ran first. This executed correctly, but then the next step caused the error above.
    The small number of associated sub-vi's are on the target PC, and have been mass compiled.
    I've had -18002 errors before, but this is one I cannot cure.
    All suggestions gratefully received.
    Gary.

    Hi Guys,
    Regarding this -18002 error when using the Run Time Engine instead of the Development Environment, what is the VI within the step that is failing (in any of the cases you've mentioned) trying to do? Are they built around any toolkits?
    In my experiments with a simple VI (with just a user dialogue) using the LabVIEW 7.1 RTE in both TestStand 3.1 and 3.5 this morning, I haven't found any issues
    There is a possibility if any of the sub-VIs or toolkits you use contain a Merge Errors.vi, that the Run Time Engine picks up a copy of the VI built for previous versions of the RunTime Engine (due to the order in which the sub-VI directories are scanned), and it cannot convert it.
    There are a few solutions for this, the easiest one looks to be to copy the error.llb\Merge Errors.vi for LabVIEW 7.1 into the same directory as the VI you're calling (so TestStand can pick it up easily).
    Can you let me know if this solution helps at all? If not, would it be possible to post up any of the code or sequence you're having problems with?
    Best wishes,
    Mark
    Applications Engineer
    National Instruments

  • How to send data to labview code at run time while using with (or executing the sequence)the teststand

    Hello
    I am new to the Teststand.
    I am using labview8.0 with teststand 3.1
    I have developed some labview codemodules as vi's without using the teststand utility library pallete
    Now i have to run them in teststand.
    While executing them(as a sequence) in teststand,i need to enter the data to the labview code at run time.For this labview front panel should appear as GUI or popup (while executing).Is it possible to do this without using teststand pallete.
    or i need to change the code with teststand pallete(i think it is difficult now to change the code)
    Plz provide a solution to this problem
    Also one more,how and where to use the 'pass by reference' option
    Thanks and Regards
      Mudigondla

    Hi,
    see your other post http://forums.ni.com/ni/board/message?board.id=330&message.id=13914
    Also, you can, specify to display the front panel of your VI when you specify your VI in your sequence file.
    There are examples, for dialog panel using LabVIEW, in the examples folder of TestStand and on the NI Web Site.
    Regards
    Ray Farmer
    Regards
    Ray Farmer

  • Can i use pci-7352 to run 4 or 6 axis (motors) if i am not using them same time

    can i use pci-7352 to run 4 or 6 axis (motors) if i am not using them same time. This is a stepper motor

    This is a duplicate posting. I have answered this question here.
    Jochen Klier
    National Instruments Germany

  • LabVIEW VI with Report Generation Toolkit elements in a TestStand sequence does not run with a LabVIEW 8.5 Run-Time Engine

    Hi all,
    I am using LabVIEW 8.5.1 and TestStand 4.1. I have done a TestStand sequence with a VI in it, which uses Report Generation Toolkit elements. On my machine I am using LabVIEW and TestStand with a Development System license. On the other machine I am using TestStand with a Base Deployment license and I have chosen the LabVIEW 8.5 Run-Time Engine in the Adapter Configuration. Everything is running well except of this VI with Report Generation Toolkit elements. The error message is showing that the VI is not executable. It works well only after I have installed LabVIEW with an Evaluation license and chosen LabVIEW 8.5 Development System in the Adapter Configuration.
    I have found other posts and a document in the KnowledgeBase with a similar problem: http://digital.ni.com/public.nsf/allkb/8A0E6274D9B​D7B1986256F62006AD402?OpenDocument But I am not using EXE files in my sequence, so I don't know how to solve mine. Anybody has an idea?
    Solved!
    Go to Solution.

    Hello guys,
    thank you very much for your answers!
    @Ruediger:
    I tried to follow the instruction for Method 2 in the mentioned document: http://digital.ni.com/public.nsf/allkb/F3DC40A6E3F​3B25B862570AD005D1D3D?OpenDocument, but the steps on my machine are different starting from step 4. After I click "Continue..." in step 3, I dont get a window, the system just makes a new folder with the same VI. 
    To be honest, I am new to LabVIEW and have some difficulties at this time. What I understood from your reply is, that I need to make a LLB-File, where the files from Report Generation Toolkit are in!?
    @GovBob:
    I was following the instruction in the document: http://digital.ni.com/public.nsf/allkb/9E00E7EFE06​35E678625734600779EFE, but it wasnt working. Can you please tell me how I can check if the VI Server is installed and running on the machine?
    I am using LabVIEW 8.5.1 and TestStand 4.1 on my machine, on the deploy machine there is TestStand 4.1.1. The version of my Report Generation Toolkit is 1.1.2.
    Kind regards, Roman

  • LabVIEW 8.0 Run Time Engine

    Hi,
    I've a question about LabVIEW 8.0 run time engine.
    I installed "LabVIEW_8.0_Runtime_Engine" from the NI website, but NI software in Add/Remove Programs does not list LabVIEW 8.0 Runtime Engine. However, LV 7.0 and 7.1.1 run time engines are listed in there. 
    Did anyone notice this?
    I also have installed TestStand 3.5 on the same computer.
    When I run an executable created in LabVIEW 8.0, I get the error message:
    "VI version is too early to convert to the current LabVIEW version" 
    Comments/suggestions are appreciated.
    Thanks.

    CarlaU wrote:
    The first thing that I would check is to go into Measurement and Automation Explorer (MAX) and click on the Software Tab. I would then check to see which version of the LabVIEW RTE shows up (if any). In theory, if the RTE shows up in MAX, then it should show up in Add or Remove Programs under National Instruments Software (highlight this and click Change....this should pull up a list of all NI products on your computer).
    It's in MAX, but not Add/Remove Programs>NI
    CarlaU wrote:
    If it doesn't show up there, then there are two other things that can be done. The first one involves modifying the Windows Registry. There are a great KnowledgeBase article that discusses how to do this in order to remove the driver.
    Nope - there's nothing to do with the RTE there either.
    CarlaU wrote:
    The second idea is to use a utility we have that I cannot post on the forum. If you create a service request via email or phone then we would be able to help you get the older versions fully uninstalled. You can create a service request at www.ni.com/ask. I hope this helps!
    Thanks Carla - I'll try that avenue.
    Copyright © 2004-2015 Christopher G. Relf. Some Rights Reserved. This posting is licensed under a Creative Commons Attribution 2.5 License.

  • LabVIEW 8.0 Run-Time engine & shared variables

    Has LabVIEW 8.0 Run-Time Engine the shared variable's support, I wonder?
    The thing is that .exe with globals/locals runs alright, but beeing replaced with shared variables it refuses to run.
    What's wrong? May be need in library(s) absend?
    Thanks.

    You can use the Shared Variable in the Run-Time Engine (you do not need DSC).
    Can you be more specific about what happens when it refuses to run? Are you seeing an error message?
    If you are using Network-Published shared variables, they need to be deployed before you run the application.  You can either deploy them manually with the project, or your application can programmatically deploy them.  You can find some more information about this in the LabVIEW Help under "Shared Variables and Stand-Alone Applications or Shared Libraries" (follow this link and scroll down to the bottom):
    http://zone.ni.com/reference/en-XX/help/371361A-01/lvconcepts/project_variables/
    -Chris

  • LabVIEW 2009 SP1 Run-Time Engine (Minimum) (32-bit) for Windows - Supported Features

    Hi,
    Can some one please point out what features are supported by the LV RTE (Minimum ) [LabVIEW 2009 SP1 Run-Time Engine (Minimum) (32-bit) for Windows]
    1) Is there a limit on the size of the exe which can be run on it?
    2) Will this support additional modules like DAQ etc.,? Or do we have to chose the regular installer ( 170 Mb ) for that purpose?
    3) If a list of what it does or does not support is available, it would be extremely helpful.
    Thanks In advance.
    Regards,
    Vijay

    Anand, 
    I did go through both the links that you had sent earlier before posting on the forum. For eaxample refer the following link where it says,
    http://joule.ni.com/nidu/cds/view/p/lang/en/id/1599
    It does not contain the full run-time engine, but will allow some executables to run.
    1) What do they mean by 'some' executables. Is there a list of yay's and no's available?
    2) Can someone from NI reply to this and shed more knowledge?
    Regards,
    Vijay 

  • Can't reload Photoshop elements 7 on my windows 7 operating system. Everything goes well and it appears to be installing. All of the sudden the Installer starts to roll back everything and error message shows up saying I can't use this product at this tim

    can't reload Photoshop elements 7 on my windows 7 operating system. Everything goes well and it appears to be installing. All of the sudden the Installer starts to roll back everything and error message shows up saying I can't use this product at this time.

    How do I do that? I'm the only user on the laptop - I kind of assumed I already was running the install as the admin.

  • Can I use LabVIEW to program a Galil controller​, such as the DMC 740?

    Can I use LabVIEW to program a Galil controller, such as the DMC 740?  need a driver.

    vmagui,
    I don't know a Galil DMC-740. Do you mean the Galil DMC-1740? In this case you are talking about an ISA bus board and it might be hard to find a PC that provides ISA bus slots and enough power to run an up to date LabVIEW version.
    In general LabVIEW is an open platform, so if Galil provides a LabVIEW library or at least a well documented DLL you should be able to use their boards in LabVIEW. You should contact Galil for this information.
    If you are really talking about an ISA board you should consider an upgrade to a newer bus technology like PCI. NI also provides a whole range of high quality motion control products that are at least comparable to Galil boards (http://www.ni.com/motion). A good LabVIEW integration for these devices is self-evident and they integrate easily with other NI products like multifunction data acquisition boards, machine vision products and bus interfaces.
    Kind regards,
    Jochen Klier
    National Instruments
    Message Edited by Jochen on 07-22-2008 04:37 PM

  • Is Labview 5.0 run-time compatible with windows XP?

    A client has a Labview 5.0 application (in japanese) running on a Win98 computer, they need to run it on a WinXP computer,
    is it enough to install the LabVIEW 5.0 run-time on the WinXP computer for the application to work?
    Where can I get the LabVIEW 5.0 run-time engine?

    See here.
    Time for your client to upgrade.

  • HT4901 I have HughesNet with a capped amount of Internet capacity. How can I use iCloud but adjust the time it is on to conserve my Internet allowance and not have to backup my information all the time????

    I have HughesNet satellite for an ISP with a capped amount of Internet capacity. How can I use iCloud but adjust the time it is on to conserve my Internet allowance and not have to back up my information all the time?

    Thanks Roger W1,
    Yes, I was using iTunes to sync over cable without problems since orinigal purchase in 2011 and using 10.6 w/o problem. There was an "update" in Nov 2012 that crashed the sync service. I went to the Apple Store and reviewed the problem with the Geniuses there. It was discovered at that time that the update included mandated use of iCloud but enough of the un-updated code remained that he was able to patch functions to allow Microsoft Office to still sync over iTunes.
    This March (+/-) there was another "update" to 10.6 that totally destroyed the patch that was in place so there was no sync service available between Microsoft and iTunes what-so-ever. Then recently, because of some unknown process, all my notes, contacts, and calendars were erased in both my Apple utilities and Microsoft utilities.
    After many hours of frustration I was able to recover most of the information to the Apple utilities only, but those were unstable. At my visit to the Apple store it was suggested that an upgrade to 10.8 might solve the stability problem. That it did but being connected to the iCloud all the time keeps using up all my Internet time and I have nothing left to check emails or do research.
    This, to me, is not my problem but one created by Apple. I have searched the Internet and support groups and there doesn't seem to be a solution.
    The "aircraft mode" turns off all other communication functions and is not acceptable. Neither is disconnecting/turning off Airport on my MBP.
    Thanks,
    Jay

  • Since installing an icon-editing add-on, I can't open tabs any more / I can only use one tab at a time.

    Ever since I installed the add-on Favicon Picker 2 that lets you change the bookmark icons, I can't open tabs any more. The second tab will open, but if you try to go to a site, the FIRST tab redirects to that site. Basically, I can only use one tab at a time. Is there any way I can keep this add-on and use tabs?

    Oh, wow - look at that, you're right :) I didn't want to uninstall the add-on as I like the feature, but simply by disabling it you can keep the new icons AND use tabs. Thanks dude!
    (The add-on is Favicon Picker 2 0.6.2.15 by the way - some of the user reviews report the same problem.)

  • Can you use Apple TV to run Ap Players on your TV

    I use the comcast xfinity player and the ABC player on my  to watch on-line content.  I also access their respective web site directly from the Mac desktop to watch contents on-line as I cant run them through on my HDMI cabapable TV as my PS3 has an incompatable operating system with the flash player to view those applications or web content on-line,
    Can I use Apple TV to run either the Aps through my TV or to directly access content from on-line sites?  (and yes, I know I can hook my mac to my tv directly via an HDMI cable, but it wont work with my stereo system and the audio is substandard)

    No, the copyright holders have too many restrictions on how you are allowed to distribut content.  So you can not stream copyrighted content over AirPlay, and ATV does not support flash.   You can only watch content on ATV that there is an app for on ATV.  i.e Netflix, Hulu, MBA, etc. etc. etc.  Sorry.

  • How can I use LabVIEW to send the equivalent of a CTRL D (in VT 100 format) out the serial port of my computer?

    I am trying to write a vi that interfaces with a piece of OEM equipment that is set up to talk with a VT 100 terminal. I can't seem to locate the ASCII equivalent string (if there is such a thing) of a CTRL D. Is there a vi that emulates VT 100 commands?

    If I recall, CTRL-D is EOF on most ASCII tables.
    You'd probably have to use an escape sequence
    or if you can use an unsigned 8-bit that might be
    easier.
    In article <[email protected]>, TLS
    wrote:
    > How can I use LabVIEW to send the equivalent of a CTRL D (in VT 100
    > format) out the serial port of my computer?
    >
    > I am trying to write a vi that interfaces with a piece of OEM
    > equipment that is set up to talk with a VT 100 terminal. I can't seem
    > to locate the ASCII equivalent string (if there is such a thing) of a
    > CTRL D. Is there a vi that emulates VT 100 commands?

Maybe you are looking for