Can't restart our input and output frs

Hi,
last month we used our AT BOXI system to help restore a folder's worth of reports that an unfortunate user had deleted in production. In the course of the restore the AT BOXI CMS and input and output frs were pointed at the restored databases.
I've now tried to repoint the CMS and frs's back to the original databases and though the CMS restarts ok the frs's refuse to restart.
The shared drive with the frs on it was 'unshared' for a while according to our server guy who helped with the restore but he says he's put it back now just as it was (though I believe the old name was atboxifrs and it's now ATboxifrs). He also says all the access rights to the share are the same.
What could be preventing the frs from restarting?
We have BOXIr2 SP4 on a Windows server.
thanks
Keith

I added the -trace parameter and created a log file, the file shows the following problem:
[Thu Oct 29 10:17:59 2009]     4628     8280     Log: level=0 cat=28 msg=35600 p=Failed to setup the root directory
sdorsf004\ATboxifrs\boxi_frs\input\ for use. Please make sure permissions are correct and there is no sharing violation.
[Thu Oct 29 10:17:59 2009]     4628     8280     Log: level=0 cat=28 msg=35600 p=Failed to setup the root directory
sdorsf004\ATboxifrs\boxi_frs\input\ for use. Please make sure permissions are correct and there is no sharing violation.
[Thu Oct 29 10:17:59 2009]     4628     8280     Log: level=0 cat=14 msg=35101 p=The root server reported an error Internal Error. (Reason: Fail to initialize file system.  Please see event log for details.).
[Thu Oct 29 10:17:59 2009]     4628     8280     trace message: SIServerController:run: Fail to initialize or uninitialize.  Reason is The root server reported an error Internal Error. (Reason: Fail to initialize file system.  Please see event log for details.).:
My server guy reckons that the account we are using has the correct permissions (though I've asked him to check that again). Is there anyway of checking for myself, or is there anything else this error message could be teeling me that I'm missing?
thanks
Keith

Similar Messages

  • Selecting separate input and output devices!

    hi, i have logic pro 8 and cant find out how to select separate devises for input and output!
    for my output (and input when recording drums) i use a alesis multimix 16 (16 track firewire desc) but for recording guitars and bass and poss vocals i would like to use my line 6 x3 live as my input devise but still using the alesis for monitoring.
    is this possible? cant figure how to do it.
    any help is great help! cheers, Dan

    In Logic 9 you can easily select different input and output devices in the Preferences Devices area. In Logic 8 you must create an aggregate device -
    http://support.apple.com/kb/HT1215
    JG

  • How can I use a different driver for audio input and output?

    I did a search of course, and came up with something about an aggregate. I have no idea what this is, how to do it, or if it would even work for me.
    What I am trying to do is:
    1) Record into Logic Express using my Tascam US-122.
    2) Have playback come out of my computer sound system, not the Tascam.
    If I go over to the Audio setup window, I can only record when the driver is set to Tascam US-122. Likewise, I can only listen to sound when my Built-In Audio is selected. It gets rather annoying going between the two.
    So, would this aggregate thing solve my problem? If so, how do I do it? Thanks for any help!
    -allen

    Yes it should do what you want.
    Go to "Audio Midi Setup", and go to the Audio menu and click "Open Aggregate Device Editor". The interface is pretty simple but if you do get stuck, just use the help function in Audio Midi Setup, as it has a step by step guide.
    Then when you return to logic, go to the Preferences>Audio>Drivers section and select Aggregate Device as the new driver rather than either the built in sound or the tascam. Then the inputs and outputs will apply to BOTH devices.

  • How can I make Apple Earphones be the Input and Output for Audio

    I have some older headphones and they aren't compatible with a Mid 2010 (Intel Core i3) 21.5 Inch iMac
    Is there some way to make Apple Earphones be the Input and Output for Audio in the iMac
    This is a problem for me personally as when I am talking to someone on Skype the iMac picks up the In-built Microphone audio, and yes the headphones I'm using do work straight from the iMac as audio output
    Any help is appreciated

    you can connect the headset to something like this
    http://www.ebay.com/itm/NEW-MaelineA-3-5mm-Female-to-2-Male-Gold-Plated-Headphon e-Mic-Audio-Y-Splitter-/381100440348
    and then connect the mic to the input and the headset to the headset port

  • I have on;y one audio port can i use it for input and output at the same time?

    i have the new macbook pro 13 in and i want to connect aguitar as input and output on an amp but i have only one audio port

    You can't use the jack as an input and output simultaneously. The solution is to look for a USB or Firewire interface to get your guitar sound into the computer.

  • Can you perform simultaneous timed digital input and output using a PCI-6120?

    Is it possible to do simultaneous timed digital input and output using a PCI-6120? It seems that timed digital operations require using the group read/write commands, which utilize an entire port. Since the PCI-6120 has only 1 digital I/O port, I would like to be able to use 2 lines as outputs and 1 line as input, and do both in a deterministic fashion. i.e. create a digital signal with known pulse widths and read an input line at a known time after the outputs were set. Is this possible to do with only one digital I/O port?

    Hello,
    This can be done in LabVIEW. There is actually an example that installs with NI-DAQ.
    Below is a link to a Knowledge Base that explains how to find the correlated digital I/O examples.
    http://digital.ni.com/public.nsf/websearch/B849664604EB34B886256D12005B5520?OpenDocument
    Just take a look at the example titled �Continuous CDIO with external clock (E).vi�
    Best regards,
    Justin Tipton
    National Instruments

  • Sound Input and Output Disappeared

    I am considering a purchase of a used Macbook Pro (4,1) from early 2008 with Snow Leopard 10.6.8 installed. When I first tried the machine, the sound input and output were absent. After removing preference files, resetting NVRAM, etc., I finally got them to work. They worked for a few weeks, but recently they disappeared again. This time, my efforts to ressurrect them have been fruitless.
    Here is what I have done in an attempt to remedy the situation:
    •Delete com.apple.audio.DeviceSettings.plist and com.apple.audio.SystemSettings.plist
    •Jiggle a digital headphone jack in the headphone port
    •Verifiy Disk and Repair Permissions
    •Reset NVRAM
    •Reset SMC
    I have read online that some people have replaced the AppleHDA.kext file with the one from 10.6.7 - however, every effort I have made to find this file has resulted in failure. I am not able to locate MacOSXupdCombo 10.6.7.pkg anywhere on the web
    Any recommendations? I was able to fix this once before - why not now? Thanks for any and all constructive input...

    Did you recieve the install disk(s) when you purchase the machine? I would try doing a back up of your data then a fresh install of the OS. Insert the disk into the mac then click restart and hold the c key, ten follow the prompts.
    If you wish to take this route, I would try the 10.6.8 combo update first (it should be fine to run it again), then if you wish you may try the 10.6.7 update. Altough I would just do a OS X reinstall and then run software update till you bring it up to date. On disk 2 there should be the AHT (Apple Hardware Test) that you can run by booting the disk holding the D key to check for a hardware fault.
    You may also make a Genius bar appointment for a free evaluation, they have more extensive diagnosis tools and would then tell you what your otions would be. (hey it's free)
    Genius Bar appointment http://support.apple.com/kb/DL1361
    10.6.8 Combo update
    http://support.apple.com/kb/DL1399
    10.6.7 Combo Update:
    http://support.apple.com/kb/DL1361
    All the Best

  • 3.1 Input and Output File Repositories

    I am having an issue with setting the input and output file repositories in 3.1.
    When I go into the CMC under servers and select them I go to the bottom of the properties and change the File Store Directory location.
    Once I do that there is a second box that says Current: %DefaultInputFRSDir% and a note in Red that I must restart the server for settings to take effect.
    I have restarted all the BO services and restarted the physical server and yet the note remains and the setting doesn't appear to take effect.
    Does anyone know what I am doing wrong?
    Also, our repositories are on a file server, and in XI R2 we changed the services in Windows to run as a user account that had access to them. How do you do that in this version?

    Got it.
    Changed the ID used to run the SIA and everything is working now.

  • SSIS: How to use one Variable as Input and Output Parameter in an Execute SQL Task

    Hello,
    i need your help,I'm working on this issue since yesterday and have no idea how to deal with it.
    As I already said in the tilte i want to start a stored procedure via a Execute SQL Task which has around 15 prameters. 10 of these should be used as input AND output value.
    As an example:
    i have three  Variable:
    var1    int        2
    var2    int     100
    var3    int     200
    the stroed procedure:
       sp_test
          @var1 int
          @var2 int output
          @var3 int output
       AS
       BEGIN
            SET @var2 = @var2 * @var1
            SET @var3 = @var3 + @var1
       END
    So in the Execute SQL Task i call the Stored Procedure as follwos:
        Exec sp_test  @var1 = ?, @var2 = ? output, @var3 = ? output
    (I use an OLE DB Connection)
    The parameter mapping is as follows:
    User::Var1        input                   numeric              0                 -1
    User::Var2        input/output         numeric              1                 -1
    User::Var3        input/output         numeric              2                 -1
    Now my problem. If i set  Var2 and Var3 as Input parameter the values are still the same after running the package. If i set them to a output value the are both Null because the procedure doesnt get any values.
    I already tried to list them a second time - like
        User::Var2        input                  numeric              1                 -1
        User::Var2        output                 numeric              1                 -1
    or i use a new variable
        User::Var2                  input                  numeric              1                 -1
        User::Var2Return        output                 numeric              1                 -1
    but i alwas get the error
    "Multiple-step OLE DB operation generated errors. Check each OLE DB status value, if available. No work was done."
    Has anybody an idea how I can solve this problem?
    Thanks a lot.
    Kind Regards,
    Alice

    Hi Alain,
    thx for your answer.
    I have around 15 procedures called one after the other to calculated and modify my values. Each procedure is responsible for an other but overlapping set of variables. So i thought it would be a good idea to call them one after the other with the needed variables via a execute sql task.
    So if i use a result set, how i get my stored procedure to return 10 values? I would have to use a Function instead of a procedure, wouldn't i?
    As if i have 15 procedures this would be a lot of work.
    But thanks a lot for the idea. I think an other idea would be to create one function which calls all stored procedures and returns all the calculated values as a result set, wouldn't it?.
    Kind Regards.
    Alice

  • How to use a bluetooth cellphone for audio input and output

    Hello, I was wondering how to set-up my Mac Book so that I can use my bluetooth cellphone for audio in and audio out. Ideally, I would like to use my handset for talking on iChat and Skype. Has anyone had any luck doing this? When I bond my cellphone these optiosn do not appear. I know that this is easy to do on a Windows machine but I am not sure about how to do it on my Mac Book.
    Thanks!

    Yes it should do what you want.
    Go to "Audio Midi Setup", and go to the Audio menu and click "Open Aggregate Device Editor". The interface is pretty simple but if you do get stuck, just use the help function in Audio Midi Setup, as it has a step by step guide.
    Then when you return to logic, go to the Preferences>Audio>Drivers section and select Aggregate Device as the new driver rather than either the built in sound or the tascam. Then the inputs and outputs will apply to BOTH devices.

  • How do I create an xControl with multiple inputs and outputs?

    Hello,
    i am trying to write a new Xcontrol Element. In the data model I can create data types using the cluster to create compound types, eg an int and an int array. But how do I create an xcontrol which has multiple data inputs and outputs?
    Kind Regards

    Limping_Twerp wrote:
    Alright: I see: An xcontrol is either an input OR an output. How do I achieve an output? Secondly: So you are saying the only Elements that can have multiple inputs and outputs are VIs?
    Can you take a few steps back and explain what you are actually trying to do. SubVIs and Xcontrols have nothing in common and it is not clear why you even try to compare them side by side (e.g. in terms of the number of connectors).
    Your questions about input or output tell us that you seems to have some misconceptions about xcontrols. Xcontrols are like regular controls, except they have some built-in intelligence that you can program. Most front panel object can be either controls or indicators and the same is true for Xcontrol. You create an Xcontrol, and after placing it on the front panel you can decide if it should be a control (where the code reads the value) or an indicator (were the code writes values to it). When you define the xcontrol facade, you also need to program how the visuals change if it is changed from control to indicator or vice versa.
    As a first step, you should opend the example finder and look at some xcontrol examples.
    Again, what are you actually trying to do? 
    LabVIEW Champion . Do more with less code and in less time .

  • FINALLY INPUTTING and OUTPUTTING Annotations!

    Ok, before everyone thinks that this is a very bad solution, I have to tell that I`m no programmer and my knowledge of PostgreSQL, Ruby or any other language is very poor.
    With useful help from Jamie Hodge, fbm and Nicholas Stokes (mainly)
    I could manage to write a command for inputting and outputting from Final Cut Server Annotations.
    So lets go to the fun part:
    INPUTTING:
    1- Create a Response called "Annotations IN" (or whatever you want):
    a - Reponse Action: "Run an external script or command"
    b - Run Script > *Commnad Path: /Library/Application Support/Final Cut Server/Final Cut Server.bundle/Contents/Resources/sbin/fcsvr_run
    Command Parameters: psql px pxdb -c "COPY pxtcmdvalue FROM '/FCSRV/annotation-in.txt' USING DELIMITERS '|';"
    2 - Create a poll Watcher with name: "Watch for Annotations IN"
    a - Enable: true
    b - Monitor Address: Chooses a Device (create a new one or use a tmp one) and path to where you`ll going to put a txt file with the annotations.
    c - Response List: Choose the Response you created "Annotations IN" in my case.
    d - Event Type Filter: Created, Modified
    e - Poll Watcher > Listing Frequency: 2 (or any number of seconds you feel like it).
    Listing multiple: 2
    Wildcard include Filter: *.txt (or any custom extensions you want)
    3 - Create a txt file and use this as a template:
    {ASSET_ENTITYID}|1527|{TCIN}/(30000,1001)|{TCOUT}/(30000,1001)|{Annotation}|{USE RID}|{DATE}
    Where:
    {ASSET_ENTITYID} = Is the entityid of your asset. You can find what number it is by issuing:
    /Library/Application\ Support/Final\ Cut\ Server/Final\ Cut\ Server.bundle/Contents/Resources/sbin/fcsvr_run psql px pxdb -c "SELECT pxmdvalue.entityid, pxmdvalue.value AS asset_name FROM pxmdvalue INNER JOIN pxentity ON pxentity.entityid = pxmdvalue.entityid WHERE pxmdvalue.fieldid='1543' AND pxentity.address LIKE '/asset/%';"
    This will output ALL your assets, so if you know the name or want to parse the name you can use:
    /Library/Application\ Support/Final\ Cut\ Server/Final\ Cut\ Server.bundle/Contents/Resources/sbin/fcsvr_run psql px pxdb -c "SELECT pxmdvalue.entityid, pxmdvalue.value AS asset_name FROM pxmdvalue INNER JOIN pxentity ON pxentity.entityid = pxmdvalue.entityid WHERE pxmdvalue.fieldid='1543' AND pxmdvalue.value='ASSETNAME' AND pxentity.address LIKE '/asset/%';"
    Where in ASSETNAME you`ll have to put your Asset Name without extension.
    {TCIN} and {TCOUT} is, of course, the TC`s points. In the form of: HH:MM:SS;FF
    {Annotation} is the commentary.
    {USERID} (in my case was 1)
    {DATE}: This one is tricky. My example is 2009-03-15 19:31:15.839795-03
    So is in the form YYYY-MM-DD HH:MM:SS.????? I really don`t know the rest. Could be milliseconds?
    Of course one can write a script to translate everything from a txt file like:
    ASSETNAME | TCIN | TCOUT | ANNOTATIONS | USER
    But as I`ve said I`m no programmer
    Ok.. now the time for the OUTPUT:
    The command-line is:
    /Library/Application\ Support/Final\ Cut\ Server/Final\ Cut\ Server.bundle/Contents/Resources/sbin/fcsvr_run psql px pxdb -c "SELECT pxmdvalue.value AS Asset_NAME, pxtcmdvalue.value, pxtcmdvalue.begintc, pxtcmdvalue.endtc FROM pxmdvalue INNER JOIN pxtcmdvalue ON pxmdvalue.entityid = pxtcmdvalue.entityid WHERE pxmdvalue.value='ASSETNAME';"
    Where ASSETNAME is the Asset name without the extension.
    Or issuing the following to OUTPUT ANNOTATIONS from ALL assets:
    /Library/Application\ Support/Final\ Cut\ Server/Final\ Cut\ Server.bundle/Contents/Resources/sbin/fcsvr_run psql px pxdb -c "select * from pxtcmdvalue;"
    Adding "> /PATHTO_WHERE_IN_WANT/ANNOTATIONSOUTPUT.TXT" at the end will put all output into a txt file.
    It`s possible (in theory) to:
    1- Create a boolean md field in FCSRV called "EXPORT Annotations" (don`t choose lookup)
    2- add or create a md group called "Export Annotations" and add the above md field to it (don`t choose lookup)
    3- Add "Export Annotations" md field to Asset Filter md group
    4- Make a Response for Running external command. Command path: /Library/Application Support/Final Cut Server/Final Cut Server.bundle/Contents/Resources/sbin/fcsvr_run
    Command Parameters: psql px pxdb -c 'SELECT pxmdvalue.value AS Asset_NAME, pxtcmdvalue.value, pxtcmdvalue.begintc, pxtcmdvalue.endtc FROM pxmdvalue INNER JOIN pxtcmdvalue ON pxmdvalue.entityid = pxtcmdvalue.entityid WHERE pxmdvalue.value=[FileName];' > ~/Desktop/ann-out.txt
    (I`m having problem with this, it doesn`t work).
    5- Make a Subscription that if Export Annotations modified = true, trigger if changed and trigger the Response above.
    6- Add exporting annotations md group to Media md set.
    In theory it`s possible to modify the FinalCutServerIntegrationSample get and input annotations instead of adding another "comment" field to md group list.
    Few!
    Ok so please help beautify this out!
    This will be very useful for a lot of people.... We know that it`s only a matter of time to FCSVR have this function built-in... but this "time" could be years.
    So let`s start ourselves!
    Thank you very much!!
    Regards!

    AlphaBlue wrote:
    jverd wrote:
    What were you hoping for? Someone reading your mind for what exactly you need, and handing you a giftwrapped answer, without you doing any work or clearly communicating a specific problem? This site doesn't really work that way.Fair enough. I'm asking for insight into how to input from and output to a StarOffice Spreadsheet into/from a Java program. (Think java.io except with spreadsheet files instead of .txt files.) I already answered that question.
    I need to accomplish this without the use of a community-created library.That's a bizarre requriement. Why?
    >
    Okay, [here you go|http://lmgtfy.com/?q=communication+between+StarOffice+Spreadsheets+and+Java].
    If you don't have any knowledge or experience, on the matter, please refrain from directing me to a google search. I assure you, I have already performed such a task.How would I know that.
    But okay, let's say I know that. Let's say you bothered to point out that you've already done that. Further, let's say I do have knowledge of the subject at hand. Maybe I'm an expert. Maybe I wrote Star Office and an open source library (which wheel for some reason you must reinvent). You are assuming that I also have psychic powers, so that I can read your mind and know exactly what you've read so far and exactly what parts of your very broad and vague question said reading did not answer.
    In short, you have received answers commensurate with your questions.

  • How to temporally match/save Input and Output Channels's data?

    Hello, I have a voltage-input, voltage-output SISO system, and need to indentify its dynamic response (or transfer function) as a reference to a PID control. Without using the system identification toolbox, my goal is to generate/provide a sine sweep input (ranging 1Hz-5kHz for 10sec) to the system and to save the corresponding output response signal as well as the sweep input signal simultaneously.
    I got a sample program online and am trying to modify it as attached, but I really need your advices/comments concerning several problems I am facing with:
    1) With the below setting, the number of the acquired Input channel samples obtained is 5461, which is smaller than expected (i.e., 10000). What would I be missing in setting parameters?
    - H/W: NI-USB-6341 DAQ
    - AO: continuous samples with the waveform timing (1k sampling, 10000 samples => 10 sec, slower sampling just for testing purpose)
    - AI: continuous samples, samples to read: 30k, rate: 1k
    2) I am using flat sequence structure as a way to making the start point of saving AI and AO data same, but wonders if this is a right method or if there is other better approaches. (I had an idea of using an internal clock with "1-sample mode" for sync, but this may not work at the high speed sine sweep like 5kHz, right?)
    3) I just want to provide the sine sweep just once to the system and do not require the "reset" functionality implemented in the original sample program. I failed to remove this "reset" part as I did not fully understand the sample code. If I run the attahed, the generated AO signal is periodically provided to the system. Please give me any advice to modify the program as I want.
    Thanks for your help and valualble time.
    Attachments:
    siso.vi ‏230 KB

    Hi J. Kim,
    To begin, you say you want to synchronize your analog input and output so that they start at the exact same time, yes? To achieve tight synchronization, you need to use DAQmx VIs instead of the DAQ Assistant. There's a good overview of DAQmx VIs  here. There's also a document that deals specifically with synchronization in DAQmx here. Additionally, if you go to Help>>Find Examples in the LabVIEW example finder, you can see many other examples of acquiring data using DAQmx.
    As for your configuration, you have your analog input DAQ assistant wired far before your analog output DAQ assistant in your sequence strucutre, so the dataflow of the program will cause the analog input DAQ Assistant to execute before the output. They cannot be in different sequences if they are executing simoultaneously, and I would not use flat sequences here except to start the two tasks in DAQmx. Where did you find this example?
    Best,
    Dan N
    Applications Engineer
    National Instruments 

  • Multiple inputs and outputs using DAQmx VIs

    Hello,
    I am fairly new with the LabView programming language.  I have a few training books that I have been reading, and I have been following online tutorials and reading the forums.  However, I have come to a problem where I don’t see a clear solution.  I am using LabView 2009 (9.0f3) and DAQmx VIs.
    I am using a NI 9172 chassis PLC, with two 9201 AI cards, 9217 AI RTD card, 9472 DO card, 9263 AO card, and two 9237 AI Bridge cards.
    I am reading eight analog inputs with the 9201 cards, two analog RTD inputs with the 9217 card, three digital outputs with the 9472 card, three analog outputs with the 9263, and eight analog inputs with the 9237 cards.
    I wrote a simple program to test one digital output task, two of the analog output tasks, and a single analog input task.  I put all of them in the same while loop, and it worked perfectly.  However, when I add analog input tasks to the same loop, I get an error 200022.    So I tested each sensor individually by changing the channel before each run.  I searched error 200022 and found that this is because I cannot start another analog input task until the previous one ends.  With this said, I don’t know how to acquire an analog voltage in the same task as an analog RTD voltage.  Both inputs take different constants in the start task DAQmx icon.
    Attached is my test program.  It is titled “Test All”. This is the program I used to test the various sensors.  I tested the input sensors one at a time, and it worked fine.  A few tasks are written just to test functionality, and will be added to later.  The data is only displayed on the screen.  I will add triggers and data write to disk functions later.  This program works now, but if I add more analog inputs, it will generate the 200022 error.
    Can someone show me how to correctly write the code for multiple inputs and outputs using DAQmx?  All training materials and tutorials I can find all show a single input or single output, not multiples of each.  Thanks for looking.
    -Randy
    Attachments:
    TestAll-NI.vi ‏32 KB

    Hi RandyC,
    The Knowledge Base article Using Different Types of DAQmx Global Channels in the Same Task goes into a little more depth of what Bryan is talking about, and it also includes some example code to help show what to do.
    Hope that helps,

  • How to Create a Rich Dynamic Input and Output PDF to insert and get data into, from Database (MSSQL)

    HI ,
    I want to use Adobe LiveCycle Designer and Adobe LiveCycle Workbench features to create a Dynamic PDF form which can allow me to store data into database(MSSQL Server) and Can also provide me the Output PDF form with all the information which has been been filled in by the User in input form. Both Input and Output forms must be Dynamic. I am stuck in this process and Need Experts Advice on the Complete optimal process flow of the Adobe.
    Regards
    Ritesh Grover

    HI
    Go to the lay out of your screen and doublr click on the table control fields, you can get the Properties/Attribute of the screen or table control Fields
    Assing a Group GRP1 for all the fields i n the table control.
    in PBO
    if ok_code = 'INPUT'.
    LOOP AT SCREEN.
    IF screen-grp1 = 'GRP1'.
    screen-input = 1.
    modify screen.
    endif.
    ENDLOOP.
    elseif ok_code = 'OUTPUT'.
    LOOP AT SCREEN.
    if screen-grp1 = 'GRP1'.
    screen-input = 0.
    modify screen.
    endif.
    endloop.
    endif.
    Regards
    Ramchander Rao.K
    Edited by: Ramchander Krishnamraju on Aug 8, 2009 5:27 AM