Can`t we configure peer-link on M1 cards?
can`t we configure peer-link on M1 cards? its showing an error while i am configuring the vpc peer link on M1 card.
ERROR: Operation failed: [Interface is not capable of acting as peer-link]
Hi,
The PC peer link can be configured on M1 series I/O modules, but only on the 10GE modules. From the Configuring vPC section of the Nexus 7000 configuration guide:
vPC Peer Links
A vPC peer link is the link that is used to synchronize the states between the vPC peer devices. Both ends of the link must be on 10-Gigabit Ethernet interfaces.
What type are your M1 I/O modules? I can't see from what you attached.
Regards
Similar Messages
-
Can some explain vpc peer-link vlan issues for me?
I remove vlan from vpn peer-link , the vpc is gonna down.
I know this is design ,but why.
thank you!
TomThanks Chad!
Kept racking my brain on that one, and the only time it would make any sense (ie, I was trying to fit a square peg in a round hole), is if you have IGP peering to each 7K from an orphan port (ex, FW), the IGP ECMP hashes a packet to the far-end 7K, and then the traffic sent to the directly attached 7K must be sent across the vpc-peerlink -- and in theory shouldn't be dropped. This is, of course, until you add peer-gateway command, which confuses matters a bit -- especially from an IGP control-plane perspective, but also in this loop-prevention rule, since the local 7K will handle the packets destined to the other's 7K MAC.
To complicate matters worse, the latest 5K release notes say to exclude-vlan for peer-gateway for your backup router vlan... still have to dive into that one. -
Can the wiki be configured to link to a file already on the server rather than uploading it into the page? This would enable users to open (and edit) the original server hosted document rather than downloading a static copy that can't be edited and synced back into the wiki page.
As a workaround I've tried attaching an alias to a file but it doesn't work - the wiki instead uploads the aliased file.
From what I can work out, the default wiki behaviour is to upload a document to a wiki page, which creates a copy of the uploaded document in the wiki database. This copy has no connection to the original document. It can be downloaded and edited, but the edits are not saved back into the wiki hosted version of the document.
I'd like to be able to upload a link or alias to a document (with preview please!) already on the server. A user could then preview the document or click to open and edit it.
The only way I can do this at the moment is to create a link "afp://123.../doc.rtf" to the original. This is timeconsuming and confusing for non-technical users and doesn't offer the benefits of the attach function (ie document preview).
Is there any way the wiki can be configured to link to documents already on the server using the attach functionality?An update for anyone in a similar situation.
Patch 3944727 for 9.0.4.1 that solves this issue: "USER LOV IASM11SHIP EDIT USER LOV SHOULD SHOW THE NICKNAME ATTRIBUTE." However, the patch is mutually exclusive with the latest CPU's and there's no plan to merge the pacthes given the dwindling support for 9.0.4.1. So that patch is pretty much worthless.
I've been told that this patch is included in newer portal versions, so the real solution is an upgrade.
Trenton -
I just added 2 vlans Port-channel10 on two of my Nexus 5000's that go from the to a 6509 Catalyst switch. I get this error when I do a show log:(VLANs 133-134 on Interface port-channel10 are being suspended. (Reason: Vlan is not allowed on Peer-link) When I do a sh int trunk I see Po10 (int Eth1/3) that Vlans Err-disabled on Trunk. Another odd thing when I do an spanning tree summary neith 133 or 134 is added in to the summary? Why would spanning-tree be ignoring these two new vlans?
They are configured as so:
interface port-channel10
description "vpc 10 eth1/3 to 6506 po10 ten5/4"
switch port mode trunk
switchport trunk native vlan 999
switchport trunk allowed vlan 130.,133-134,139,145,155,160-175,239,242,254,999
vpc10
What can I do to get 133 and 134 vlans to stop erroring on Port-channel 10 on both Nexus 5000's?Firstly I should say I have not used Nexus switches so the following advice should be treated with caution.
Have you added the same vlans to the allowed vlans on your vPC peer link. That is what the error message seems to be telling you ie. they are not currently allowed.
They need to be allowed otherwise the vlans are suspended which is what is happening.
As I say I haven't used these switches so I can't say for sure if there is any downtime/disruption when you modify the allowed list but I think that is your problem from what I can see.
Jon -
Hello,
In the case I have two N5k acting as a vPC peers and I lose the vPC peer-link between two of them, but I do not lose the vPC peer-keepalive link, what would happen when the vPC peer-link comes back again?
As I understand in the case of vPC peer-link failure all vPC member ports on the secondary N5k will be shut down. When the vPC peer-link comes back again what would happen?
I have read that in that case the vPC member ports will not come back automatically, but they will remain disabled until you do manual recovery. Is that really so?
Is there some way that we can automate the process upon recovery?
ThanksThe reload restore command has been removed/replaced and the new feature is
now called auto recovery. Auto recovery covers the use case that reload
restore addressed, plus more.
If both switches reload, and only one switch boots up, auto-recovery allows
that switch to assume the role of the primary switch. The vPC links come up
after a configurable period of time if the vPC peer-link and the
peer-keepalive fail to become operational within that time. If the peer-link
comes up but the peer-keepalive does not come up, both peer switches keep
the vPC links down. This feature is similar to the reload restore feature in
Cisco NX-OS Release 5.0(2)N1(1) and earlier releases. The reload delay
period can range from 240 to 3600 seconds.
When you disable vPCs on a secondary vPC switch because of a peer-link
failure and then the primary vPC switch fails, the secondary switch
reenables the vPCs. In this scenario, the vPC waits for three consecutive
keepalive failures before recovering the vPC links.
The vPC consistency check cannot be performed when the peer link is lost.
When the vPC peer link is lost, the operational secondary switch suspends
all of its vPC member ports while the vPC member ports remain on the
operational primary switch. If the vPC member ports on the primary switch
flaps afterwards (for example, when the switch or server that connects to
the vPC primary switch is reloaded), the ports remain down due to the vPC
consistency check and you cannot add or bring up more vPCs.
For more information, please refer to the Operations Guide: As a best practice,
auto-recovery should be enabled in vPC.
HTH,
Alex -
VPC peer-link on N7k's 1Gig link?
We are in process of setting up vPC peer between 2 N7ks over a 1Gig link, has anybody done this before? Couldn't find any documents in cisco site which talks about this. All of the documents points to setting up using 10G links.
Cheers
RajaHello Raja,
The vPC peer link must be 10Gb Ethernet otherwise it will not form. It is also mentioned here.
http://www.cisco.com/c/en/us/td/docs/switches/datacenter/sw/4_2/nx-os/interfaces/configuration/guide/if_nxos/if_vPC.html
https://books.google.co.uk/books?id=o3jeY1SwOYcC&pg=PA114&lpg=PA114&dq=peer+link+must+be+10&source=bl&ots=cZSAvLRMto&sig=YviMepi0thKtqUA2P2n3r2JkWnc&hl=en&sa=X&ei=-GauVNXwIs_waMzcgvAG&ved=0CFQQ6AEwCQ#v=onepage&q=peer%20link%20must%20be%2010&f=false
The vPC peer keep alive link by all means can be 1Gb.
HTH
Bilal -
Peer-link - mixing M1 and M2 cards on the same chassis
Hi guys,
for migrations propuses i need to add 2 links from a M2 card to the peer-link port-channel already configured in a M1 card:
N7K-1 VPC Peer link N7K-2
M2 ----------------------- M2
M1 ---------------------- M1
I cant find any documentacion for this specific cards,
we are running 6.2(8a).
Anyone can advise,
thx
regardsNo, you cannot configure the ports from an M1 and M2 series linecard in the same port
channel. This is referenced in our N7K Interfaces Configuration Guide at the following
link:
http://www.cisco.com/en/US/docs/switches/datacenter/sw/6_x/nx-os/interfaces/configuration/
guide/if_portchannel.html#wp1888267
Starting with revision 6.2, you can mix any M Series I/O modules to create a vPC peer as
illustrated in the following table.
I/O Module Combinations Supported on Both Sides of a vPC Peer Link, Cisco NX-OS Release
6.2
HTH -
(*) - local vPC is down, forwarding via vPC peer-link
Hello
Local VPC status down what is the issue-----
status -
show vpc
Legend:
(*) - local vPC is down, forwarding via vPC peer-link
vPC domain id : 1
Peer status : peer adjacency formed ok
vPC keep-alive status : peer is alive
Configuration consistency status : success
Per-vlan consistency status : success
Type-2 consistency status : success
vPC role : secondary
Number of vPCs configured : 2
Peer Gateway : Disabled
Dual-active excluded VLANs : -
Graceful Consistency Check : Enabled
Auto-recovery status : Enabled (timeout = 240 seconds)
vPC Peer-link status
id Port Status Active vlans
1 Po1 up 1,150
vPC status
id Port Status Consistency Reason Active vlans
10 Po10 down* success success -
20 Po20 down* success success -
# show port-channel summary
Flags: D - Down P - Up in port-channel (members)
I - Individual H - Hot-standby (LACP only)
s - Suspended r - Module-removed
S - Switched R - Routed
U - Up (port-channel)
M - Not in use. Min-links not met
Group Port- Type Protocol Member Ports
Channel
1 Po1(SU) Eth LACP Eth1/1(P) Eth1/2(P)
10 Po10(SD) Eth LACP Eth1/47(I)
20 Po20(SD) Eth LACP Eth1/48(I)Hi,
What is Portchannel 10 and 20 for? They are both down.
Can you post the config from both switches?
HTH -
Duplicate address across VPC peer-link on Nexus 7010
Just set up a VPC peer-link between two 7010 switches. The peer-link is a port-channel of two 10Gb connections. On both sides I'm seeing this in the log:
2010 Jan 5 04:27:34 CRMCN7K-1 %ARP-2-DUP_SRC_IP: arp [3069] Source address of packet received from 0024.f716.b341 on Vlan401(port-channel10) is duplicate of local, 10.180.0.17
and on the other
2010 Jan 5 04:23:39 CRMCN7K-2 %ARP-2-DUP_SRC_IP: arp [3052] Source address of packet received from 0024.f71f.a7c1 on Vlan401(port-channel10) is duplicate of local, 10.180.0.18
VLAN 401 is the only VLAN on them right now with a Layer 3 address. What am I missing? Everything looks correct. Port-Channel10 is up and running fine..or so it seems.Hey Nashwj,
What version of NX-OS are you running?
Are the 7K in a stand alone environment (lab or similar) or connected to other production network devices?
Are both of the VLANs carried across the vPC peer link port-channel?
Are both of the VLANs carried across any vPC port-channel?
Do you have HSRP setup on the VLAN 401 interfaces on each of the 7Ks? If so, what are the real and vip IP addresses?
If you can either provide answers to the above or configuration snapshots of the vPC and SVI interfaces for your VLANs on each of the 7Ks a solution should be reachable. -
How can i wrote configuration file in Log4j
iam new log4j .i have seen one small programme in log4j examples folder ..i e. shown below
Sort.java
=====
package examples;
import org.apache.log4j.PropertyConfigurator;
import org.apache.log4j.Logger;
import org.apache.log4j.Priority;
Example code for log4j to viewed in conjunction with the {@link
examples.SortAlgo SortAlgo} class.
<p>This program expects a configuration file name as its first
argument, and the size of the array to sort as the second and last
argument. See its <b>source
code</b> for more details.
<p>Play around with different values in the configuration file and
watch the changing behavior.
<p>Example configuration files can be found in <a
href="doc-files/sort1.properties">sort1.properties</a>, <a
href="doc-files/sort2.properties">sort2.properties</a>, <a
href="doc-files/sort3.properties">sort3.properties</a> and <a
href="doc-files/sort4.properties">sort4.properties</a> are supplied with the
package.
<p>If you are also interested in logging performance, then have
look at the {@link org.apache.log4j.performance.Logging} class.
@author Ceki Gülcü */
public class Sort {
static Logger logger = Logger.getLogger(Sort.class.getName());
public static void main(String[] args) {
if(args.length != 2) {
usage("Incorrect number of parameters.");
int arraySize = -1;
try {
arraySize = Integer.valueOf(args[1]).intValue();
if(arraySize <= 0)
usage("Negative array size.");
catch(java.lang.NumberFormatException e) {
usage("Could not number format ["+args[1]+"].");
PropertyConfigurator.configure(args[0]);
int[] intArray = new int[arraySize];
logger.info("Populating an array of " + arraySize + " elements in" +" reverse order.");
for(int i = arraySize -1 ; i >= 0; i--) {
intArray[i] = arraySize - i - 1;
SortAlgo sa1 = new SortAlgo(intArray);
sa1.bubbleSort();
sa1.dump();
// We intentionally initilize sa2 with null.
SortAlgo sa2 = new SortAlgo(null);
logger.info("The next log statement should be an error message.");
sa2.dump();
logger.info("Exiting main method.");
static void usage(String errMsg) {
System.err.println(errMsg);
System.err.println("\nUsage: java org.apache.examples.Sort " + "configFile ARRAY_SIZE\n"+
"where configFile is a configuration file\n"+" ARRAY_SIZE is a positive integer.\n");
System.exit(1);
and
SortAlgo.java
==========
package examples;
import org.apache.log4j.Category;
import org.apache.log4j.NDC;
Example code for log4j to viewed in conjunction with the {@link
examples.Sort Sort} class.
<p>SortAlgo uses the bubble sort algorithm to sort an integer
array. See also its <b>source
code</b>.
@author Ceki Gülcü */
public class SortAlgo {
final static String className = SortAlgo.class.getName();
final static Category CAT = Category.getInstance(className);
final static Category OUTER = Category.getInstance(className + ".OUTER");
final static Category INNER = Category.getInstance(className + ".INNER");
final static Category DUMP = Category.getInstance(className + ".DUMP");
final static Category SWAP = Category.getInstance(className + ".SWAP");
int[] intArray;
SortAlgo(int[] intArray) {
this.intArray = intArray;
void bubbleSort() {
CAT.info( "Entered the sort method.");
for(int i = intArray.length -1; i >= 0 ; i--) {
NDC.push("i=" + i);
OUTER.debug("in outer loop.");
for(int j = 0; j < i; j++) {
NDC.push("j=" + j);
// It is poor practice to ship code with log staments in tight loops.
// We do it anyway in this example.
INNER.debug( "in inner loop.");
if(intArray[j] > intArray[j+1])
swap(j, j+1);
NDC.pop();
NDC.pop();
void dump() {
if(! (this.intArray instanceof int[])) {
DUMP.error("Tried to dump an uninitialized array.");
return;
DUMP.info("Dump of integer array:");
for(int i = 0; i < this.intArray.length; i++) {
DUMP.info("Element [" + i + "]=" + this.intArray);
void swap(int l, int r) {
// It is poor practice to ship code with log staments in tight
// loops or code called potentially millions of times.
SWAP.debug( "Swapping intArray["+l+"]=" + intArray[l] +
" and intArray["+r+"]=" + intArray[r]);
int temp = this.intArray[l];
this.intArray[l] = this.intArray[r];
this.intArray[r] = temp;
This program expects a configuration file name as its first
argument, and the size of the array to sort as the second and last
argument. See its <b>source
code</b> for more details.
please help me how can write that configuration file
thanksHi bala,
check that log4j manual I pointed to in yer previous thread.
This is a pot-boiler config file... Copy it into some file say "props.conf" and use it.
# Set root logger level to DEBUG and its only appender to A1.
log4j.rootLogger=DEBUG, A1
# A1 is set to be a ConsoleAppender.
log4j.appender.A1=org.apache.log4j.ConsoleAppender
# A1 uses PatternLayout.
log4j.appender.A1.layout=org.apache.log4j.PatternLayout
log4j.appender.A1.layout.ConversionPattern=%-4r [%t] %-5p %c %x - %m%nCheers, -
How can i add a new link to Portal favorites?
Hi,
I have created a portal application and configured it to a porta frame work page byy adding iViews and portal pages.
I would like to display an iView as a link in the portal favorites. I have added it to portal favorites as related link. But nothing is displayed in the portal favorites when i logged in as application user.
How can i add a link to the created iView just like the "DeveloperContent" link shown in portal favorites when we login as portal administrator?
Your help and suggestions solicited...
Best regards,
SudheeshHi Sudheesh,
The Related Links option is for Content Administrators to add links that they think will be useful for a certain page or iView...an end user can't add their own links to the Related Links iView. Also, you don't need Knowledge Management installed in the Portal for the Related Links iView to work. Also, Related Links will be available only on the pages/iViews that the Content Administrator has created them.
Read more about Related Links here:
http://help.sap.com/saphelp_nw04/helpdata/en/e3/1d37600aa111d7b84700047582c9f7/frameset.htm
Portal Favorites is a nice option for end users to decide which iViews or pages they would like to be available from every Portal page.
To open new iViews/pages in a new window, rather than in the current Content Area, adjust the Workprotect mode of the portal (either the user can do it for their preference or the Administrator can do it for everyone):
http://help.sap.com/saphelp_nw04/helpdata/en/15/4b673e214ad112e10000000a11405a/frameset.htm -
There is no ITUnes grogra on my laptop....so nothing to delete. ITunes error says that it can not be configured. Have tried dumping my temp file and restarting....no help.
Hi jackdaniels63,
Welcome to Apple Support Communities.
Try following along with the article linked below, which will have you completely remove iTunes and it's related components before trying to reinstall iTunes again.
Removing and reinstalling iTunes and other software components for Windows Vista, Windows 7, or Windows 8
http://support.apple.com/kb/HT1923
-Jason -
Using SNMP is it possible to find the vPC peer link of a Nexus 5K?
I'm trying to use SNMP to get the Peer Link pair...
hi,
You can include 0calyear characteristic before the structure in the column and set it to no display and show result row.
regards,
Arvind. -
Can MRPG be configured in UCCE
Can MRPG be configured in UCCE? If yes, can you let me know the configuration steps and the interface that will be used between UCCE and MRPG
Hi Jennifer,
check page 93 of the deployment guide of IPCC.
below is the link for your quick ref.
IPCC Deployment Guide.
http://www.google.co.in/url?sa=t&rct=j&q=&esrc=s&source=web&cd=4&ved=0CDgQFjAD&url=http%3A%2F%2Fwww.cisco.com%2Fen%2FUS%2Fdocs%2Fvoice_ip_comm%2Fcust_contact%2Fcontact_center%2Fcisco_interaction_manager%2Fcim_432%2Fuser%2Fguide%2Fcisco_im432deploymentguide.pdf&ei=egsnUtOnEMq6lQXv74GwAw&usg=AFQjCNHrkmgc3UBZgxO6q1BHbJ0grpV4tg&bvm=bv.51495398,d.dGI
Regards
Sandeep -
Can i keep configuration settings (polling frequency...) outside BPEL
Dear All,
Can i keep configuration settings (polling frequency and other which are typically set in BPEL adapter outside BPEL
so that at runtime BPEL will look at this configuration file instead of settings inside BPEL.
Regards
ArcI think you can. If you define them as properties in the Adapter wsdl (by prepending a $), then you can set their values in bpel.xml. And the values in bpel.xml are exposed in the bpel console under the descriptors link. so you can modify these values at runtime, without having to undeploy the bpel process.
--Amit
Maybe you are looking for
-
I'm using my ipad2 with iMovie. When I import photos from my pc and try to use them they are huge. Even when I resize them in photoshop they are still huge and unusable. How do I resize them?
-
Thinkpad X230 displayport goes blank on resolution switch
Hi, I'm using an external monitor NEX MultiSync EA244WMi connected via Displayport to my X230 (Windows 7 Pro 64bit). I happen to use different graphics settings for various purposes - from extended desktop at full resultion to external only at 1024x7
-
Hi all, am having problem to iterate to next record when using when validate record trigger. what else can be used instead of next_record to iterate through? thanks.
-
When try to install n-gage software get error -10254 anyone any ideas?
-
Cannot find Version, Year, Period dimension while reversing Planning App
Hi I am using Planning application as target for dimension loading. When i try to reverse the planning app using RKM Hyperion Planning. On reversing i could not find Version, Year & Period as datastores after reverse. Is it dependent on planning appl