Can we call a responsibility from a OA Page
Hello All ,
Can we invoke a responsibility from a OA page , for example like opening a Install Base Responsibility with a button click from a SalesUser page .
If so can you give the outline of the process .
A response is highly appreciated.
Thank you ,
P.Srikanth .
Resp. will be tied to a Top Level Menu, which in turn would be launching a Home Page Menu. You can forward to this Home Page Func., to achieve your requirement.
Similar Messages
-
How can i call a zreport from my bsp page.
Hi friends,
How can i call a zreport from my bsp page.
MoosaHi Friend,
These are the codings to be wirtten in BSP for transferring values to the REPORT
DATA:wf_date TYPE ztable-ID.
data:seltab type standard table of rsparams,
wa_seltab like line of seltab,
event TYPE REF TO if_htmlb_data.
DATA:p_value TYPE REF TO CL_HTMLB_INPUTFIELD.
event = cl_htmlb_manager=>get_event( runtime->server->request ).
p_requ ?= CL_HTMLB_MANAGER=>GET_DATA(
request = runtime->server->request
name = 'inputField'
id = 'i1'
if p_requ is not initial.
wf_date = p_requ->value.
endif.
clear wa_seltab.
if wf_date is not initial.
wa_seltab-selname = 'P_REQU'.
wa_seltab-kind = 'P'.
wa_seltab-option = 'EQ'.
wa_seltab-low = wf_date.
append wa_seltab to seltab.
endif.
submit *ZSAMPLEAP1* with selection-table seltab AND RETURN .(ZSAMPLEAP1 refers to the report name and AND RETURN for coming back to the BSP page after the completion of its operation in Report )
IMPORT int_name TO int_name FROM MEMORY ID '*zid*'.(For importing the obtained value from Report)
In Report
REPORT ZSAMPLEAP1.
SELECT-OPTIONS: p_requ FOR ztable-id NO INTERVALS.
SELECT SINGLE name from ztable into int_name WHERE id = p_requ-low.
WRITE:int_name.
EXPORT int_name TO MEMORY ID 'zsharmila'.
With Regards,
SHARMILA BRINDHA.M -
Can we Call a Servlet from a OA Page?
Hi All
My requirement is to call a servlet's doPost method from ProcessFormRequest.
I have created one custom OA page. One submit button is there on OA page.When i click submit button it will go to controller's proessFormRequest method and from this method i have to call servlet's doPost method.
Can we do that?
Please Suggest
Best Regards
MajidHi Majid,
You can use the following method.
pageContext.setForwardURL("ABC.jsp",
null, // not necessary with KEEP_MENU_CONTEXT
OAWebBeanConstants.KEEP_MENU_CONTEXT, // no change to menu context
null, // No need to specify since we're keeping menu context
hashmap, // params, // request parameters
true, // retain the root application module
OAWebBeanConstants.ADD_BREAD_CRUMB_NO ,// display breadcrumbs
OAWebBeanConstants.IGNORE_MESSAGES );//
Thanks
Anoop -
How can I Call the MainVI from its SubVI, and this happen recursively?
Hi All,
How can I Call the MainVI from its SubVI, and this happen recursively?
Actually, LAbView 7.1 doesn't support recurssion?
Plz help me out!Dear GerdW,
Thanks a lot 2 all of u guys,for all the brilliant responses.
Actually, my basic aim is to call the Main VI, containing a SubVI.....
Now, I want to call my main VI from this SubVI...recursively!!!!!..but whenever I tried to put the MainVI in this SubVI..an error message pops out saying recursive calling is not possible.
I also tried using "Call by reference" but tht also didn't worked...an d error is somewat like...VI is invalid..or type matching..or state matching error.
Here, Im attaching the snapshot of the MainVI... Im calling the SUBvi from it... It is running GOOD n FINE...
But prob arrives when I call the Main from the SUBvi, which looks like same as MainVI(with little differences).
I hope, Im clear in my words n not being ambigous.
Plz, correct me where ever im wrong.
Thank You.
Mishra_RnD
Attachments:
ScrShot.JPG 272 KB -
How can i call a servlet from a servlet ?
Hello,
Can i call a Servlet from within a Servlet ?
and is it "right thing" to Do ?
ThanksJMO, but I wouldn't do it like this.
Don't have a remote object like a servlet doing database queries for your app. That will mean TWO network hops for every query if the database resides on another machine. The network is the biggest bottleneck you've got.
Write a JavaBean that does the database stuff for you and just have the first servlet instantiate it when it needs it. A Bean has a better chance of being reused, too. Write a TableGateway or DAO for your object.
Or write an EJB to do it.
The only time I've done a servlet-to-servlet connection like that was for one servlet running in a DMZ that would authenticate a user and then forward the request to another servlet running inside the second firewall.
I wouldn't encapsulate database query logic in a servlet like that. JMO - MOD -
How can I call a function from a procedure
I have a function named: f_calc_value which return the variable v_result. This function is part of a package.
How can I call this function from a new procedure I am creating?
Thanksor refer this theread....calling function from procedure
-
How can I call a RFC from dynpage ?
Hi!
I would like to know how can I call a RFC from a Portal aplication, dynpage or jspdynpage. there include some libraries ?
any idea?
thanksfor deploying SAP Jra :
https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/ad09cd07-0a01-0010-93a9-933e247d3ba4#search=%22how%20to%20use%20jca%20sapjra%20site%3Asap.com%22
For lookup of SAP Jra use:
com.sapportals.connector.connection.IConnectionFactory connectionFactory =(IConnectionFactory) initctx.lookup( "deployedAdapters/SAPFactory/shareable/SAPFactory");
Using SAP Jra
http://help.sap.com/saphelp_nw04s/helpdata/en/47/13044258bdd417e10000000a1550b0/content.htm
The important jars required are:
connector.jar
Genericconnector.jar
prtjndisupport.jar
Thanks -
I have just recently installed ios6 to my iPad 3 an iPhone 4 my iPhone works fine but my iPad is not working at all I can not get a response from it, it seemed to download an then install but did not reset and turn on and will not turn on HELP!! Withdrawal or what!! Lol
Hi there,
Firstly, try a hard reset. Hold the sleep/wake and home buttons together until the Apple logo appears.
If this doesn't work, try restoring your device. Put it in recovery mode if iTunes doesn't recognise it, and restore it from there. I have linked to instructions below.
Recovery Mode and Restore - Apple
Let me know if this helps,
Nathan -
I have a function from a dll that return a double* string and an integer. How can I call this function from LabVIEW? There is a possibility to work in LabVIEW with a double* string?
pcbv wrote:
> Hello all,<br><br>The header of the function is:
>
> "HRESULT WRAPIEnumerateDevices(WRAPI_NDIS_DEVICE **ppDeviceList, long *plItems);"
>
> where WRAPI_NDIS_DEVICE have this form:
>
> typedef struct WRAPI_NDIS_DEVICE<br>{<br>
> WCHAR *pDeviceName;<br>
> WCHAR *pDeviceDescription;<br><br>}
> WRAPI_NDIS_DEVICE;<br><br>
>
> The function is from WRAPI.dll, used for communication with wireless card.
> For my application I need to call in LabVIEW this function.
Two difficulties I can see with this.
First the application seems to allocate the array of references
internally and return a pointer to that array. In that case there must
be another function which then deallocates that array again.
Then you would need to setup the function call to have a pointer to an
int32 number for the deviceList parameter and another pointer to int32
one for the plItems parameter.
Then create another function in your DLL similar to this:
HRESULT WRAPIEnumExtractDevice(WRAPI_NDIS_DEVICE *lpDeviceList, long i,
CHAR lpszDeviceName, LONG lenDeviceName,
CHAR lpszDeviceDesc, LONG lenDeviceDesc)
if (!lpDeviceList)
return ERROR_INV_PARAMETER;
if (lpDeviceList[i].pDeviceName)
WideCharToMultiByte(CP_ACP, 0,
pDeviceList[i].pDeviceName, -1,
lpszDeviceName, lenDeviceName,
NULL, NULL);
if (lpDeviceList[i].pDeviceName)
WideCharToMultiByte(CP_ACP, 0,
pDeviceList[i].pDeviceDescription, -1,
lpszDeviceDesc, lenDeviceDesc,
NULL, NULL);
return NO_ERROR;
Pass the int32 you got from the first parameter of the previous call as
a simple int32 passed by value to this function (and make sure you don't
call this function with a higher index than (plItems - 1) returned from
the first function.
Rolf Kalbermatter
Rolf Kalbermatter
CIT Engineering Netherlands
a division of Test & Measurement Solutions -
Can I call a report from pl/sql?
How can I call a report from pl/sql? I would like the output to be pdf and have it outputted to the screen?
We are running Oracle 10g database and 10.1.2.3 application server on LInux Redhat 4.
Thanks.
Shirley
Edited by: jonesfnalgov on Jul 12, 2011 2:17 PM
Edited by: jonesfnalgov on Jul 12, 2011 2:18 PMHello,
a package is provided : srwAPIins.sql installs the Event-Driven Publishing API.
http://download.oracle.com/docs/cd/B14099_17/bi.1012/b14048/pbr_evnt.htm
The Event-Driven Publishing API is a PL/SQL package that provides the basic functions required for the development of procedures that respond to events in the database. Event-driven jobs are submitted using the HTTP protocol. The server assigns a unique job_ident record to every call, useful for tracking the status of the job.
Regards -
Can LabVIEW call a function from a .sys file or is LabVIEW limited to dll access?
My vendor has sent me a .sys file with functions accessing their hardware. Can i call these function from labview directly or do I have to wrapper the .sys with a dll?
Well a sys file is a kernel device driver. LabVIEW does not have any direct way of accessing such a driver. The way kernel drivers are accessed is usually through a DLL which makes calls to WinAPI functions such as CreateFile(), ReadFile(), WriteFile(), CloseHandle() and DeviceIORequest(). Since these WinAPI calls are basically just DLL calls too, you could theoretically use the Call Library Node to call them and access the kernel device driver in such a way.
However for any kernel device driver with more than one or two device driver calls, it will certainly be easier in terms of development, debugging and maintenance of the code, to write actually a dedicated DLL in C/C++ for this device driver and access that DLL from LabVIEW, especially if you consider the LabVIEW datatype limitations when designing the DLL interface (Basically this same DLL can then be called from any other Windows development environment, be it Visual Basic (similar datatype limitation as LabVIEW), Delphi, (Visual) C, LabVIEW or also various scripting environments like Python and Lua.
Some of the necessary WindAPI calls are rather involved and pose quite a bit of trouble to get the parameter data right in LabVIEw.
Rolf Kalbermatter
CIT Engineering Netherlands
a division of Test & Measurement Solutions -
Can we call a BDC from REPORT program.
hi
can anybody tell me that
can we call a BDC from REPORT program.
thanks®ardsYes, It can be called.
Infact you can generate a program from SHDB recording and in the program generated you can put necessary report logic and call the BDC/CALL TRANSACTION as required.
<b>Please check here for a sample program,</b>
http://www.sapdevelopment.co.uk/bdc/bdc_ctcode.htm
Regards
Kathirvel -
Can we call a transaction from a report
hi
can we call a transaction from a reporthi,
we can call
check it
*& Report ZSALESORDERDETAILS_ASHOK
REPORT ZSALESORDERDETAILS_ASHOK
NO STANDARD PAGE HEADING
LINE-SIZE 50
LINE-COUNT 35(5).
*data declaration.
tables :vbak.
tables: VBAP.
DATA : TVBAK LIKE VBAK OCCURS 0 WITH HEADER LINE,
TVBAP LIKE VBAP OCCURS 0 WITH HEADER LINE,
TEMP TYPE p decimals 5 VALUE '0.0' ,
A type i,
FIELDNAME TYPE STRING,
FIELDVALUE TYPE VBAP-VBELN.
DATA G_CB.
selection-screen begin of block screen1 with frame title TEXT-001.
SELECTION-SCREEN SKIP.
SELECTION-SCREEN COMMENT /32(35) COMM1.
SELECTION-SCREEN ULINE /27(35).
SELECTION-SCREEN SKIP.
SELECT-OPTIONS TVBELN FOR VBAK-VBELN.
SELECTION-SCREEN SKIP.
SELECTION-SCREEN ULINE.
SELECTION-SCREEN COMMENT /30(50) COMM2.
SELECTION-SCREEN ULINE /27(40).
SELECTION-SCREEN SKIP.
SELECT-OPTIONS TERDAT FOR VBAK-ERDAT.
SELECTION-SCREEN SKIP.
selection-screen end of block screen1.
*Initialization
Initialization .
TVBELN-low = 4000.
TVBELN-high = 5000.
TVBELN-option = 'BT'.
TVBELN-sign = 'I'.
APPEND TVBELN.
TERDAT-low = '19960202'.
TERDAT-high = '20020302' .
APPEND TERDAT.
AT SELECTION-SCREEN .
SELECT *
FROM VBAK
INTO TABLE TVBAK
WHERE VBELN IN TVBELN AND erdat IN Terdat .
IF sy-subrc ne 0.
MESSAGE 'ENTERED ORDER NOT FOUND' type 'E'.
ENDIF.
START-OF-SELECTION.
REFRESH TVBAK.
SELECT *
FROM VBAK
INTO TABLE TVBAK
WHERE VBELN IN TVBELN AND ERDAT IN TERDAT.
END-OF-SELECTION.
LOOP AT TVBAK.
WRITE: /2 SY-VLINE,
TVBAK-VBELN INPUT ON ,
15 SY-VLINE,TVBAK-ERDAT hotspot on,
30 SY-VLINE, 35 TVBAK-ERNAM,
46 SY-VLINE,
g_cb AS CHECKBOX.
ENDLOOP.
A = SY-LINCT - SY-LINNO - 1.
SKIP A .
RESERVE A LINES.
AT SELECTION-SCREEN OUTPUT.
comm1 ='SELECT SALES ORDER RANGE'.
comm2 ='SELECT SALES ORDER CREATION DATE'.
TOP-OF-PAGE.
ULINE.
WRITE /15 ' SALES ORDER REPORT ' COLOR = 1 .
ULINE.
WRITE : /7 ' VBELN ' COLOR = 5 ,
19 ' ERDAT ' COLOR = 5,
34 ' ERNAM ' COLOR = 5.
ULINE.
END-OF-PAGE.
IF SY-LSIND = 0.
ULINE.
WRITE : /2 'NUMBER OF LINE IN THIS PAGE = ', SY-LINNO.
SKIP.
WRITE: /30 'PAGE NUMBER = ', SY-PAGNO.
ULINE.
ELSEIF SY-LSIND = 1.
ULINE.
WRITE : /12 'TOTAL PRICE = ' ,TEMP.
CLEAR TEMP.
SKIP.
WRITE : /30 'PAGE NUMBER = ', SY-PAGNO.
ULINE.
ENDIF.
at line-selection.
GET CURSOR FIELD FIELDNAME VALUE FIELDVALUE.
IF FIELDNAME = 'TVBAK-VBELN'.
CALL FUNCTION 'CONVERSION_EXIT_ALPHA_INPUT'
EXPORTING
INPUT = FIELDVALUE
IMPORTING
OUTPUT = FIELDVALUE.
WINDOW STARTING AT 60 2 ENDING AT 120 25.
IF SY-LSIND = 1.
SELECT
FROM VBAP
INTO TABLE TVBAP
WHERE VBELN EQ FIELDVALUE.
LOOP AT TVBAP.
TEMP = TEMP + TVBAP-NETPR.
WRITE : /2 SY-VLINE, TVBAP-matnr,
17 SY-VLINE,TVBAP-VBELN,
30 SY-VLINE,TVBAP-NETPR currency 'IN',
49 SY-VLINE.
ENDLOOP.
ULINE.
A = SY-LINCT - SY-LINNO - 1.
SKIP A .
RESERVE A LINES.
ENDIF.
<b>ELSEIF SY-LSIND = 2.
call transaction 'MM01' .
ENDIF.</b>
TOP-OF-PAGE DURING LINE-SELECTION.
WRITE : / SY-ULINE,
/7 ' DETAIL OF GIVEN SALES ORDER ' COLOR = 5,
/ SY-ULINE,
/4 'MATNR',
22 'VBELN',
35 'NETPR',
/ SY-ULINE.
Regards
ASHOK
Message was edited by:
ASHOK KUMAR -
Can we call a bdc from a report program?
hi
Can we call a bdc from a report program?
Thanks
RamaHello,
Yes..
Check this example:
FORM USER_COMMAND USING R_UCOMM LIKE SY-UCOMM
RS_SELFIELD TYPE SLIS_SELFIELD.
DATA : L_EBELN TYPE EKPO-EBELN,
L_EBELP TYPE EKPO-EBELP.
DATA : L_DATE1 TYPE SY-DATUM,
L_DATE2 TYPE SY-DATUM,
L_YEAR(4),
L_MONTH(2),
L_DATE(2).
DATA: L_AMOUNT1 LIKE RK40C-WTGBTR.
DATA: L_POSID_OLD TYPE PS_POSID.
DATA: L_POSID_NEW TYPE PS_POSID.
DATA: LS_COBK LIKE COBK.
DATA: LT_ITEMS LIKE RK40C OCCURS 0 WITH HEADER LINE,
LT_COEP LIKE COEP OCCURS 0 WITH HEADER LINE,
LT_COEPL LIKE COEPL OCCURS 0 WITH HEADER LINE,
LT_COEPR LIKE COEPR OCCURS 0 WITH HEADER LINE,
LT_MESG LIKE MESG OCCURS 0 WITH HEADER LINE.
DATA: LV_NUM TYPE POSNR_ACC VALUE '1'.
DATA: CD_SEND_REC_REL LIKE COHEADER-SEND_REC_REL,
LD_STATUS LIKE RK23F-STATUS.
DATA: L_DYNNR LIKE FELD-DYNNR.
CLEAR : L_DATE,L_DATE1,L_DATE2,L_YEAR,L_MONTH.
L_DATE1 = SY-DATUM.
L_YEAR = L_DATE1(4).
L_MONTH = L_DATE1+4(2).
L_DATE = L_DATE1+6(2).
CONCATENATE L_DATE L_MONTH L_YEAR INTO L_DATE2 .
CASE R_UCOMM.
WHEN '&IC1'. "doubleclick
CHECK RS_SELFIELD-FIELDNAME = 'EBELN'.
READ TABLE G_T_FINAL INDEX RS_SELFIELD-TABINDEX.
IF SY-SUBRC = 0.
READ TABLE G_T_TEMP WITH KEY LOGNUM = G_T_FINAL-LOGNUM.
IF SY-SUBRC = 0.
MESSAGE I899(KB) WITH TEXT-004.
ELSE.
CLEAR : L_EBELN,L_EBELP,LS_COBK,LT_ITEMS,G_T_BDC,G_T_MESSAGE,
CD_SEND_REC_REL,LD_STATUS.
REFRESH: LT_ITEMS,G_T_BDC,G_T_MESSAGE.
SET PARAMETER ID 'BES' FIELD G_T_FINAL-EBELN.
GET PARAMETER ID 'BES' FIELD L_EBELN.
SET PARAMETER ID 'BSP' FIELD G_T_FINAL-EBELP.
GET PARAMETER ID 'BSP' FIELD L_EBELP.
SORT G_T_FINAL BY EBELN EBELP.
READ TABLE G_T_FINAL WITH KEY EBELN = L_EBELN
EBELP = L_EBELP
BINARY SEARCH.
IF SY-SUBRC = 0.
LS_COBK-KOKRS = G_T_FINAL-KOKRS.
LS_COBK-GJAHR = SY-DATUM+0(4).
LS_COBK-VRGNG = 'RKU1'.
LS_COBK-PERAB = SY-DATUM+4(2).
LS_COBK-PERBI = SY-DATUM+4(2).
LS_COBK-BLDAT = SY-DATUM.
LS_COBK-BUDAT = SY-DATUM.
LS_COBK-CPUDT = SY-DATUM.
LS_COBK-USNAM = SY-UNAME.
LS_COBK-WSDAT = SY-DATUM.
LS_COBK-KURST = 'M'.
LS_COBK-VARNR = '05SAP'.
LS_COBK-KWAER = G_T_FINAL-WAERS.
LS_COBK-CPUTM = SY-UZEIT.
CLEAR : L_POSID_OLD,L_POSID_NEW.
CALL FUNCTION 'CONVERSION_EXIT_ABPSP_INPUT'
EXPORTING
INPUT = G_T_FINAL-POSID_NEW
IMPORTING
OUTPUT = L_POSID_NEW.
CALL FUNCTION 'CONVERSION_EXIT_ABPSP_INPUT'
EXPORTING
INPUT = G_T_FINAL-POSID_OLD
IMPORTING
OUTPUT = L_POSID_OLD.
L_AMOUNT1 = G_T_FINAL-AMOUNT.
LT_ITEMS-ZLENR = LV_NUM.
LT_ITEMS-EPSPNR = L_POSID_NEW.
LT_ITEMS-SPSPNR = L_POSID_OLD.
LT_ITEMS-KSTAR = G_T_FINAL-KSTAR.
LT_ITEMS-WAERS = G_T_FINAL-WAERS.
LT_ITEMS-WTGBTR = L_AMOUNT1.
LT_ITEMS-WKGBTR = L_AMOUNT1.
APPEND LT_ITEMS.
CLEAR: LT_ITEMS.
* For reposting the Cost
CHECK NOT LT_ITEMS[] IS INITIAL.
CALL FUNCTION 'K40C_COBK_CHECK_POST'
CHANGING
ITCOBK = LS_COBK
EXCEPTIONS
PERIOD_BLOCKED = 1
EXTERNAL_NUMBER_MISSING = 2
ERROR_OCCURED = 3.
IF SY-SUBRC IS INITIAL.
CALL FUNCTION 'K40C_DOCUMENT_LINE_CHECK'
EXPORTING
DOC_HEADER = LS_COBK
IGNORE_WARNINGS = 'X'
TABLES
DOC_ITEMS = LT_ITEMS.
*...Create Tables for database
CALL FUNCTION 'K40C_DOCUMENT_CREATE'
EXPORTING
DOC_HEADER = LS_COBK
TABLES
DOC_ITEMS = LT_ITEMS
ITCOEP = LT_COEP
ITCOEPL = LT_COEPL
ITCOEPR = LT_COEPR.
CALL FUNCTION 'K40C_DOCUMENT_POST'
TABLES
ITCOEP = LT_COEP
ITCOEPL = LT_COEPL
ITCOEPR = LT_COEPR
CHANGING
DOC_HEADER = LS_COBK.
ENDIF.
ENDIF.
IF SY-SUBRC = 0.
GET PARAMETER ID 'KBXXN_P_VAR_RKU1' FIELD CD_SEND_REC_REL.
GET PARAMETER ID 'KBXX_START_DYNPRO' FIELD LD_STATUS.
IF CD_SEND_REC_REL IS INITIAL AND LD_STATUS IS INITIAL.
CLEAR L_DYNNR.
L_DYNNR = '1220'.
PERFORM BDC_DYNPRO USING 'SAPLK23F1' '1200'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'COHEADER-SEND_REC_REL'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=PVAR'.
PERFORM BDC_FIELD USING 'COHEADER-SEND_REC_REL'
'05SAP'.
PERFORM BDC_FIELD USING 'RK23F-STATUS'
'L'.
PERFORM BDC_FIELD USING 'COHEADER-BLDAT'
L_DATE2.
PERFORM BDC_FIELD USING 'COHEADER-BUDAT'
L_DATE2.
PERFORM BDC_FIELD USING 'COHEADER-PERIO'
L_MONTH.
PERFORM BDC_DYNPRO USING 'SAPLK23F1' '1200'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'RK23F-STATUS'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=LISI'.
PERFORM BDC_FIELD USING 'COHEADER-SEND_REC_REL'
'05SAP'.
PERFORM BDC_FIELD USING 'RK23F-STATUS'
'S'.
PERFORM BDC_FIELD USING 'COHEADER-BLDAT'
L_DATE2.
PERFORM BDC_FIELD USING 'COHEADER-BUDAT'
L_DATE2.
PERFORM BDC_FIELD USING 'COHEADER-PERIO'
L_MONTH.
PERFORM FILL_BDC_SCREEN USING L_DYNNR L_DATE2 L_MONTH.
ENDIF.
IF CD_SEND_REC_REL EQ '05SAP' AND LD_STATUS EQ 'S'.
CLEAR L_DYNNR.
L_DYNNR = '1220'.
PERFORM FILL_BDC_SCREEN USING L_DYNNR L_DATE2 L_MONTH.
ELSEIF CD_SEND_REC_REL EQ '05SAP' AND LD_STATUS EQ 'L'.
CLEAR L_DYNNR.
L_DYNNR = '1220'.
PERFORM BDC_DYNPRO USING 'SAPLK23F1' L_DYNNR.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'RK23F-STATUS'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=LISI'.
PERFORM BDC_FIELD USING 'COHEADER-SEND_REC_REL'
'05SAP'.
PERFORM BDC_FIELD USING 'RK23F-STATUS'
'S'.
PERFORM BDC_FIELD USING 'COHEADER-BLDAT'
L_DATE2.
PERFORM BDC_FIELD USING 'COHEADER-BUDAT'
L_DATE2.
PERFORM BDC_FIELD USING 'COHEADER-PERIO'
L_MONTH.
PERFORM FILL_BDC_SCREEN USING L_DYNNR L_DATE2 L_MONTH.
ELSEIF CD_SEND_REC_REL NE '05SAP' AND LD_STATUS EQ 'S'.
CASE CD_SEND_REC_REL.
WHEN '01SAP' OR '02SAP' OR '04SAP' OR '08SAP' OR '09SAP'.
CLEAR L_DYNNR.
L_DYNNR = '1220'.
WHEN '03SAP' OR '07SAP'.
CLEAR L_DYNNR.
L_DYNNR = '1230' .
WHEN '06SAP'.
CLEAR L_DYNNR.
L_DYNNR = '1210'.
WHEN '10SAP'.
CLEAR L_DYNNR.
L_DYNNR = '1270'.
ENDCASE.
PERFORM BDC_DYNPRO USING 'SAPLK23F1' L_DYNNR.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'COHEADER-SEND_REC_REL'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=PVAR'.
PERFORM BDC_FIELD USING 'COHEADER-SEND_REC_REL'
'05SAP'.
PERFORM BDC_FIELD USING 'RK23F-STATUS'
'S'.
PERFORM BDC_FIELD USING 'COHEADER-BLDAT'
L_DATE2.
PERFORM BDC_FIELD USING 'COHEADER-BUDAT'
L_DATE2.
PERFORM BDC_FIELD USING 'COHEADER-PERIO'
L_MONTH.
PERFORM BDC_FIELD USING 'RK23F-WAERS'
'EUR'.
PERFORM FILL_BDC_SCREEN USING L_DYNNR L_DATE2 L_MONTH.
ELSEIF CD_SEND_REC_REL NE '05SAP' AND LD_STATUS EQ 'L'.
CASE CD_SEND_REC_REL.
WHEN '01SAP' OR '02SAP' OR '04SAP' OR '08SAP' OR '09SAP'.
CLEAR L_DYNNR.
L_DYNNR = '1220'.
WHEN '03SAP' OR '07SAP'.
CLEAR L_DYNNR.
L_DYNNR = '1230' .
WHEN '06SAP'.
CLEAR L_DYNNR.
L_DYNNR = '1210'.
WHEN '10SAP'.
CLEAR L_DYNNR.
L_DYNNR = '1270'.
ENDCASE.
PERFORM BDC_DYNPRO USING 'SAPLK23F1' '1200'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'COHEADER-SEND_REC_REL'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=PVAR'.
PERFORM BDC_FIELD USING 'COHEADER-SEND_REC_REL'
'05SAP'.
PERFORM BDC_FIELD USING 'RK23F-STATUS'
'L'.
PERFORM BDC_FIELD USING 'COHEADER-BLDAT'
L_DATE2.
PERFORM BDC_FIELD USING 'COHEADER-BUDAT'
L_DATE2.
PERFORM BDC_FIELD USING 'COHEADER-PERIO'
L_MONTH.
PERFORM BDC_DYNPRO USING 'SAPLK23F1' '1200'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'RK23F-STATUS'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=LISI'.
PERFORM BDC_FIELD USING 'COHEADER-SEND_REC_REL'
'05SAP'.
PERFORM BDC_FIELD USING 'RK23F-STATUS'
'S'.
PERFORM BDC_FIELD USING 'COHEADER-BLDAT'
L_DATE2.
PERFORM BDC_FIELD USING 'COHEADER-BUDAT'
L_DATE2.
PERFORM BDC_FIELD USING 'COHEADER-PERIO'
L_MONTH.
PERFORM FILL_BDC_SCREEN USING L_DYNNR L_DATE2 L_MONTH.
ENDIF.
CALL TRANSACTION 'KB11N' USING G_T_BDC MODE G_MODE MESSAGES
INTO G_T_MESSAGE.
IF NOT G_T_MESSAGE[] IS INITIAL.
READ TABLE G_T_MESSAGE WITH KEY MSGTYP = 'S'.
IF SY-SUBRC = 0.
DELETE FROM BALHDR WHERE LOGNUMBER = G_T_FINAL-LOGNUM AND
OBJECT = G_T_FINAL-OBJECT AND
SUBOBJECT = G_T_FINAL-SUBOBJECT.
COMMIT WORK.
G_T_TEMP = G_T_FINAL.
APPEND G_T_TEMP.
ENDIF.
ENDIF.
ENDIF.
ENDIF.
CLEAR G_T_MESSAGE.
REFRESH G_T_MESSAGE.
*refresh g_t_bdc.
CLEAR G_T_BDC.
REFRESH G_T_BDC.
ENDIF.
ENDCASE.
ENDFORM. " USER_COMMAND
Vasanth -
Can we call a procedure from a trigger
Can we call a procedure from a trigger
thanksWhy cant you test yourself..?
SQL> ed
Wrote file afiedt.buf
1 create or replace procedure p1
2 as
3 begin
4 null;
5* end;
SQL> /
Procedure created.
SQL> ed
Wrote file afiedt.buf
1 create or replace trigger t1
2 after insert on t
3 begin
4 p1;
5* end;
SQL> /
Trigger created.
SQL> insert into t
2 values(5,'n');
1 row created.
Message was edited by:
jeneesh
Maybe you are looking for
-
As the subject suggests I want to restore my iPhone 4 to it's factory settings and am wondering if I need to have an internet and/or itunes connection in order to do that? I just don't want to get 1/2 way through the reset and get stuck because I don
-
REP-110: Unable to open file
9iAS report server has been configured. There is Infrastructure & Business Intelligence Forms home is on same server. When i try to run the demo url from web browser : http://<FQDN server>:8888/reports/rwservlet?destype=cache&desformat=PDF&report=Inv
-
Hi, I need to put an authority check before saving in Tcode VK11. I used BADI SD_COND_SAVE_A to put the checking. I needed to output a message then go back to the same screen with the entered values in the screen still in it. How Can I make the progr
-
How to change subscription from PC to Mac?
How do I change my Windows Creative Cloud to Mac? I am buying a MacBook Pro in September and my subscription will renew tomorrow. Should I cancel and then make another one for Mac?
-
Which software won't work on Intel Macs?
Hi, I wonder if you would know of a list of program versions and compatibillity with the new Intel based Macs. Thanks in advance!