Cancelling Inspection Lots - In Process Lots 03 origin

Hi,
I have recently deployed the QM module of ECC 6 to interact with a LIMS system via QM-IDI interface as part of an overall ECC 6 implementation. I generate inspection lots in the following scenarios:
1. Goods Receipt from Purchase Orders
2. In process inspections during production
3. Goods Receipt from Production
4. Recurring Inspections of existing stocks
5. Customer Returns
For scenario 1,3,4 and 5 the inspeciton lot has an associated goods movement, therefore if there is a cancellation of i.e. a GR then the associated inspection lot is also cancelled. However scenario 3 is driven by the release of a process order and therefore no goods movement. If a process order is cancelled (techo'd) can the associated inspection lot be cancelled?

Yes.. it is done from within the process order.  Not sure of the menu title but it's like the the first one on the left, and then additonal functions if I remember correctly.  You should find Cancel inspection lot listed as a choice.
Craig

Similar Messages

  • Cancel inspection lot of origin 09 type

    Hi,
    i want to cancel inspection lot 09 type and inpection lot status is CRTD CHCR SPRQ.
    So pl help me how i cancel this lot .
    Regards,
    Prakash

    Dear Prakash,
    Inspection lot  with origin 9 is  the lot  generated  for Recurring inspection. You define in Material master  the 'inspection interval'  in days, so once that many days are passed  the system will automatically  post the stock of that batch from  unrestricted to quality.
    Once the lot is generated  you should inspect that lot and post stock to unrestricted.
    If you don't want lots of 09 origin to generate do following :
    1) Remove 09 inspection type from material master.
    2) Remove the Inspection interval from material master
    3) Remove the materials from QA07 (deadline monitoring if batches)
    This will ensure that  no lots from 09 origin are generated.
    Best Regards,
    Shekhar

  • Cancel Inspection Lot where UD has been done

    Hi Experts,
    If a user has Posted Inspection stock wrongly and also made the usage decission for a Inspection Lot.Then user relealised and want to correct the stock postings.In this case I'm going to cancel the inspection lot but sys is giving me the error "ststus check error , Usage decision has been made".
    Kindly give me solution to how to correct the Inspection Lot.
    Regards,
    Sri.....

    HI All,
    I Maintained my own inspection type in the material masters which is the copy of 01 Inspection type.
    1)As you suggested to maintain the inspection type 08 - Stock transfer inspection in the material master then do the transfer posting  for 322 movement type, Do i need to change the material masters every time for this inspection or do i need to maintain 08 defaulty for all the material masters.
    2) In case if GRN is 10 qty
         Accepted qty  is 5
         Returned qty is  5.
    Now in the above case user has entered wrong qty in both Accepted and returned  and did the UD.So how reverse or cancel the lot to process the lot again with correct qty.
    Regards,
    Sri..

  • RE:Cancelled Inspection lot

    Hi All,
    I am facing an issue. Due to some reasons I had to cancel all my operation level confirmations for a production orders which also resulted in the cancellation for the inspection lot for the inspection type 04 created. Now I am trying to process the inspection lot again,but the message the system is prompting is : the inspection lot has been cancelled" Now I cannot proceed further untill I do the inpection.
    Please advice me what should be done in this case.
    One more concern.
    As I have mentioned that I had reversed the confirmation,now when I try to see the confirmation qty for in-process inspection I dont find any qty. I think this is due to reversal of the confirmation.As the confirmation for in process inspection is done while result recording,In my case the RR & UD is also done. So,In case please advice how to proceed.
    Regards,
    Vivek
    Edited by: vivek sharma on Sep 28, 2008 10:05 AM

    hi
    1. as you have cancelled all the operation leval confirmation, so system had  cancell subsequently the lot created against the GR.
    as lot is cancelled you can not process the lot.
    so you need to do the order confirmation again , so sytem will create one more lot.
    2.here i need to advice one point generally the inprocess inspection (03) will not ahve the qty postings. only the stock will be posted against the GR for production(04).
    -ashok

  • Cancel inspection lot when results already recorded

    Hi,
    I have an inspection lot created via the release of a process order, since the lot has been created the process order has been canceled and now there is a requirement to cancel the associated inspection lot also. However there are results recorded and confirmed against the inspection lot and the option in QA02 Functions ->Inspection lot -> cancel is no longer available? Any suggestions on how to cancel this inspection lot would be greatly appreciated.
    Regards,
    Gary

    Dear,
    You need to use transaction QA12. In the intial screen enter the Inspection lot number and enter. From menu bar "Usage Decision" ->Functions->Cancel Lot and then save the lot.
    Please refer this link,
    [ Cancel Inspection Lot |Re: cancel QM inspection lot]
    Regards,
    R.Brahmankar

  • Cancel Inspection Lots

    Hi,
    We need cancel inspection lots should be disappear automatically without UD
    Regards,
    SADAN

    Hi Graig,
    Some times Inspection lot created after production is cancelled due to some reason, i.e we cancel the confirmation of the process order and again reconfirm the process order. So after above activities we get two inspection lot, Previous one has status  LTCA and last one has status REL. We proceed ahead against REL only and Lot which has status LTCA remain reflecting useless in the system.
    So we need LTCA Status should not be dispalyed after some time (let say 5 days).
    This is my concern only.
    Regards,
    SADAN

  • Inspection Lot for Process Order without Header Material

    Guys,
    We have an scenario that we create a Process Order without Header material using T code CORO. Is it possible to assign or create  a Inspection lot for Process order?
    Regards,
    Senthilraja

    Hi
    Please refer
    QPL10004 User subscreen for displaying additional data in insp. lot
    Regards
    Sujit

  • How to differentiate the insp lots with same lot origin

    Hi,
    My client is
    1. Procuring a  Finished good directly ( same way as Raw material is being procured ) & then sale it.
    2. In another scinarion the same material may be produced at Vendor's end ( Sub contracting )
    3. In another scinario this is in house produced material.
    Now the requirement is seperate tracking / list for each case.
    Inspection type 04 can be activated to address the 3'rd case.
    But how to segregate 1'st & 2'nd case from each other ???
    I have created one new inspection type Z01 for lot origin 01. Similarly insp type 01 is also activated.
    If Z01 insp type is marked as preferred insp type, then system always consider this insp type.
    How to differentiate inspection type Z01 & 01  at incoming inspection stage ????
    regards,

    Dear Gajesh / Roderick
    Thanks for reply & Sorry for the delayed reply from my side.
    Gajesh as per your suggestion i used the break point in user exit QAAT0001 & after that i have executed PO & MIGO transaction, But after executiing it did not stop at a particular break point.
    AM i doing some thing wrong???? or any alternate solution is there??
    Roderick,  i have explored the status profile but found to be use fulll for changing stage one time only.  i.e. between 0101 to 01. But here i want to choose the inspection type base on PO type.
    Kindly suggest further action.
    Once abain thanks.
    regards,
    Singh
    Edited by: Singh15667 on Jul 24, 2009 10:54 AM

  • Copy the inspection  result  from one lot to multiples lots!!

    Hi SAP expert,
    I want to copy the inspection  result  from one lot to multiples lots, currently i know how to setup  the copy to another lot(SAML Response from SAP ID Service ) , but  i dont know to do to multiples lot.
    ¿Someone can help me?
    Thank you

    First you have to customizing the functionality of Copy of Inspection Results using the following path, where you have to entry the inspection types, plant .etc., where you want to have the functionality.
    SPRO -> Quality Management -> Quality Inspection -> Make Settings for Copy of Inspection Results
    Then when you are in Record Result screen you select Menu -> Edit -> Copy Inspection Results ,
    then a pop-up window is displayed and you filled in with the inspection lot which has the results and then another pop-up window is displayed to select the characteristics that you want to copy.
    A.P.

  • Printing a label listing all SFC-Nr. of a process lot

    Hi
    I would like to print out a document or Label out of SAP ME, listing all SFC of a process lot.
    When printing out the label on binding method SFC, there is 1label/SFC created
    When printing out the label on binding method PROCESS_LOT, only the first SFC is listed, but not all SFC of the Processlot.
    Is the indexing (which is used for example for SFC Data) the right instrument?
    e.g. DATA_BY_PROCESS_LOT.SFC_DATA.SFC_HEADER_DATA.SFC_NUMBER0 (NUMBER0 to NUMBER25)?
    I'm glad for any help.
    BR
    Yvonne

    Hi Stuart
    Thanks for your prompt answer
    We use ME 6.0
    And I would Need a list of all 25 SFC-Nr. in the process lot.
    but unfortunately, I just receive one SFC-Nr. out of the 25SFC, which are in the ProcessLot.
    In the how-to-guide, it is explained, that for SFC-Data, if there are multiple customer data, the SFC_CUSTOM_DATA.ATTRIBUTE Field Needs to be indexed.
    What I was wandering, is whether for the listing of all the SFC-Nr., this would be the same indexing, like I wrote in my first question.
    KR
    Yvonne

  • Booking NC-Codes on single SFC in POD Layout for Process lots

    Hi
    We work with MES 6.0 and work with Process Lots with different amount of SFC in one Process Lot.
    We would like to work with the POD-Layout showing the Process Lots in work-list.
    But on the other side, we need to book NC-Codes on single SFC, but we don't use Standalone-NCcode-Booking.
    Now, what we would like to do, is to Change the jop from the actual POD-Layout to an other one,showing SFC instead of PL, to be able to book NC-Codes. I can do this with an activity, but Operation and Resource stay empty on POD.
    Is there any possiblity to place placeholder in the Activity-Link "com/sap/me/wpmf/Client/template.jsf?WORKSTATION="BLABLA"&OPERATION=value"
    Thanks in advance for an answer
    Kind regards
    Y. Zurbuchen

    Hi Konstantin
    Because I have different operations and resources, and therefore, I'd have lots of different activities and different POD's as I link the "subPOD" at the Operation.
    Regards
    Yvonne

  • Copy  result  to one lot  to all lots

    hear i faced one  business senario  i done  settings  copy inspection results to  one lot to another lot  now  business requirement is  copy inspection result one lot to all lots means i have  01 inspection  type  lots  10 i recorded result one lot  then i want to copy to result  all lots in one shot  is it possible  in sap  if it is possible kindly tell solo

    No its Not possible.Actually process of the copy of Inspection result form one lot to other Automatically/manually is triggered when you go inside the inspection lot to which it has to be transferred.Then you select the lot from the list from where you want to transfer.
    So mass copy is really not possible.
    You may have to create the program customized for the same.

  • I was synching my iphone 4 and unplugged it. It's now stuck on a screen that has the chord and the music note that says itunes under it. I have tried to reboot and have even cancelled my last synching process. My phone is froze

    I was synching my iphone 4 and unplugged it. It's now stuck on a screen that has the chord and the music note that says itunes under it. I have tried to reboot and have even cancelled my last synching process. My phone is froze. I need help.

    You probably have to go through a restore of the phone.
    Plug the phone in and launch iTunes, then select your phone from the left side of the menu.
    There will be an option to restore the phone and click that button.
    That will erase and restore the phone.  After it's done, it will ask you to restore from a recent backup, and you can choose to go ahead and restore.
    You should be back up and running from there, but may have to do some minor tweeks to get yourself back up exactly as you left off.  Some things like your visual voicemail password and email passwords may have to be entered again, but you'll be in good shape.

  • FP05-Payment Lot/ FP25-Check Lot

    Hi
    Can anyone tell me the diffences between the above two T.Codes.
    which transactions code we should use for cheque payment. like single receipt.
    In case of outgoing payment of single cheque with cheque print which transaction i have to use apart from FPY1.
    Thanks

    Hello,
    FP05= Creates Payment Lot
    FP25 = Creates Cheque Lot
    In chq lot you can capture the chq info. It all depends on the policy of your co to choose bt them. usually if the incoming bank file provides you chq no, Chq lot is used
    Even if it is single chq payment, you have to use FPY1.
    Hope this helps
    Rgds
    Rajendra
    pnts!

  • Component Pick Release - Lot, Serial and 'Lot & Serial' Controlled Items

    Hi All,
    Please help understand how Component Pick Release handles Lot, Serial and 'Lot and Serial' Controlled component items.
    Regards,
    Abhishek

    This message pops up, if the supply subinventory has "Allow Reservation" checked. But since you have mentioned that you have checked that. Unable to think of anything else.
    Since the pickset option is turned on, move orders will be generated only if stock is avl for all the components. So, mention as you have already, ensure if avl mtl has been reserved already.