Catalyst 2950 Protocol

Hi,
We received this question from our CSC Twitter community.
Miles312
@cisco_support Am a Netacad student; was working with a Catalyst 2950, and ping gave protocol not running error. How can I check protocols?

Had Layer 3 up, as we could test that with other devices, and had a VLAN set, as management vlan and had native vlan through it with IP set.
Even pinging from the switch to another directly connected switch with the management vlan address (same subnet, layer 3 unnecessary) gave me that error.
However, two switches on either side of the one giving me this issue could ping one another, and the PC's connected to this switch could ping to one another, and to the management interfaces through layer 3.
See my bafflement?
Thanks for the reply, though! Will check the procs.

Similar Messages

  • Help with Catalyst 2950 G

    Hi,
    I have a doubt about the Catalyst 2950 series, i need to pass both IP and OSI traffic trought a 2950 switch. Is it supported?
    Thanks

    The 2950 is a layer2 switch. Anything carried over ethernet will go, no matter which layer3 protocol is used.
    Regards,
    Leo

  • RARP Server for Catalyst 2950 Switch

    Is there a RARP Server capability for the Cisco Catalyst 2950 Switch? I know that Cisco Routers support an "ip rarp-server" command. Do Cisco Switches support RARP?

    To the best of my knowledge, the RARP protocol is working with cisco 2950 switch and also it supports in most of the cisco products.
    http://www.cisco.com/en/US/tech/tk648/tk361/technologies_tech_note09186a00800f0804.shtml

  • Catalyst 2950 interface problem

    Hi, Sirs.
    My Catalyst 2950-24 (IOS Ver 12.1.22EA7)stops communicate with an other switch port of a Catalyst 3512XL-EN after catalyst 2950 powered on 1 or 2 days.
    th show interface shows that 2476498 ignored.
    FastEthernet0/1 is up, line protocol is up (connected)
    Hardware is Fast Ethernet, address is 000d.28c0.cf41 (bia 000d.28c0.cf41)
    MTU 1500 bytes, BW 100000 Kbit, DLY 100 usec,
    reliability 255/255, txload 1/255, rxload 1/255
    Encapsulation ARPA, loopback not set
    Keepalive set (10 sec)
    Full-duplex, 100Mb/s, media type is 100BaseTX
    input flow-control is unsupported output flow-control is unsupported
    ARP type: ARPA, ARP Timeout 04:00:00
    Last input 3d19h, output 00:00:00, output hang never
    Last clearing of "show interface" counters never
    Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
    Queueing strategy: fifo
    Output queue: 0/40 (size/max)
    5 minute input rate 28000 bits/sec, 44 packets/sec
    5 minute output rate 0 bits/sec, 0 packets/sec
    10033048 packets input, 806430104 bytes, 2476489 no buffer
    Received 10031591 broadcasts (0 multicast)
    0 runts, 0 giants, 0 throttles
    0 input errors, 0 CRC, 0 frame, 0 overrun, 2476498 ignored
    0 watchdog, 2217265 multicast, 0 pause input
    0 input packets with dribble condition detected
    357799 packets output, 25835259 bytes, 0 underruns
    0 output errors, 0 collisions, 2 interface resets
    0 babbles, 0 late collision, 0 deferred
    0 lost carrier, 0 no carrier, 0 PAUSE output
    0 output buffer failures, 0 output buffers swapped out
    what does is mean?

    Hello,
    what other switches do you have in your network ? If you have just the 2950 and the 3500, make sure that the 2950 is the root switch for all your VLANs, by configuring the global command:
    spanning-tree vlan x priority 0
    Also, check the log on the 2950 for the following message:
    SCHAN ERROR INTR: SRC=6 DST=5 OPCODE=20 ERRCODE=5
    If you see those, chances are that you have a faulty unit. Here is the relevant bug info:
    CSCdv83336 Bug Details
    Under certain level of traffic load, the (2950) switch will start logging the following messages on the console:
    SCHAN ERROR INTR: SRC=6 DST=5 OPCODE=20 ERRCODE=5
    and after a few seconds, the switch will stop passing any traffic. In some cases, the switch seemed still forwarding broadcast and multicast traffic, which will cause STP problem if the switch has redundant link and is not supposed to be the root for the VLAN, as both port will go forwarding.
    The same error message has been identified in CSCdu87836.
    An assessment of the impact
    Unit stops passing any traffic.
    WORKAROUND
    Several units were returned by CISCO. The units were re-screened to the latest test program, and failed the SDRAM memory test.
    Customer should RMA unit back to Cisco
    Regards,
    Nethelper

  • Catalyst 2950 trouble

    I have been trying to get a Catalyst 2950 switch to work for over a week now. I received the switches with no box or packaging and I was told that there were no previous setup attempts on it. I tried performing the express setup but the lights on the server don't seem to behave the way the instructions explain. I also was never able to make a connection between the linux server I am trying to use to configure the switch and the switch. All i received was the switch and nothing else. I have an AC power cord and I also found an RJ45 - DB 9 adapter if needed. I have looked through alot of the manuals on the cisco main pages and nothing seems to be working or clicking. Please help!

    Results of pinging from switch to linux box and switch to switch were both 0%.
    Switch2>show arp
    Protocol Address Age (min) Hardware Addr Type Interface
    Internet 192.168.1.10 - 000a.8a7a.f280 ARPA Vlan1
    No luck pinging switch from linux box again...
    Arp -a Results
    c358-hsrp102.xxxxx.com (xxx.xxx.102.1) at 00:00:0C:07:xx:xx [ether] on eth0
    Route -n Results
    Kernel IP routing table
    Destination Gateway Genmask Flags Metric Ref Use Iface
    192.168.1.0 0.0.0.0 255.255.255.0 U 0 0 0 eth1
    xxx.xxx.102.0 0.0.0.0 255.255.254.0 U 0 0 0 eth0
    169.254.0.0 0.0.0.0 255.255.0.0 U 0 0 0 eth1
    0.0.0.0 148.174.102.1 0.0.0.0 UG 0 0 0 eth0
    Ifconfig results
    eth0 Link encap:Ethernet HWaddr 00:13:72:FD:xx:xx
    inet addr:xxx.xxx.102.78 Bcast:148.174.103.255 Mask:255.255.254.0
    inet6 addr: fe80::213:72ff:fefd:871d/64 Scope:Link
    UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1
    RX packets:38172 errors:0 dropped:0 overruns:0 frame:0
    TX packets:16406 errors:0 dropped:0 overruns:0 carrier:0
    collisions:224 txqueuelen:1000
    RX bytes:8127476 (7.7 MiB) TX bytes:3941903 (3.7 MiB)
    Interrupt:169
    eth1 Link encap:Ethernet HWaddr 00:13:72:FD:87:1E
    inet addr:192.168.1.1 Bcast:192.168.1.255 Mask:255.255.255.0
    inet6 addr: fe80::213:72ff:fefd:871e/64 Scope:Link
    UP BROADCAST MULTICAST MTU:1500 Metric:1
    RX packets:0 errors:0 dropped:0 overruns:0 frame:0
    TX packets:0 errors:0 dropped:0 overruns:0 carrier:0
    collisions:0 txqueuelen:1000
    RX bytes:0 (0.0 b) TX bytes:0 (0.0 b)
    Interrupt:225
    eth2 Link encap:Ethernet HWaddr 00:04:23:CD:B5:6A
    BROADCAST MULTICAST MTU:1500 Metric:1
    RX packets:0 errors:0 dropped:0 overruns:0 frame:0
    TX packets:0 errors:0 dropped:0 overruns:0 carrier:0
    collisions:0 txqueuelen:1000
    RX bytes:0 (0.0 b) TX bytes:0 (0.0 b)
    Base address:0xecc0 Memory:fe9e0000-fea00000
    eth3 Link encap:Ethernet HWaddr 00:04:23:CD:B5:6B
    BROADCAST MULTICAST MTU:1500 Metric:1
    RX packets:0 errors:0 dropped:0 overruns:0 frame:0
    TX packets:0 errors:0 dropped:0 overruns:0 carrier:0
    collisions:0 txqueuelen:1000
    RX bytes:0 (0.0 b) TX bytes:0 (0.0 b)
    Base address:0xec80 Memory:fe9c0000-fe9e0000
    lo Link encap:Local Loopback
    inet addr:127.0.0.1 Mask:255.0.0.0
    inet6 addr: ::1/128 Scope:Host
    UP LOOPBACK RUNNING MTU:16436 Metric:1
    RX packets:6376 errors:0 dropped:0 overruns:0 frame:0
    TX packets:6376 errors:0 dropped:0 overruns:0 carrier:0
    collisions:0 txqueuelen:0
    RX bytes:4647441 (4.4 MiB) TX bytes:4647441 (4.4 MiB)
    sit0 Link encap:IPv6-in-IPv4
    NOARP MTU:1480 Metric:1
    RX packets:0 errors:0 dropped:0 overruns:0 frame:0
    TX packets:0 errors:0 dropped:0 overruns:0 carrier:0
    collisions:0 txqueuelen:0
    RX bytes:0 (0.0 b) TX bytes:0 (0.0 b)
    Lot of info there you are only allowed 3 attachments thats why i put it all in here and attached the last 2 hope you can find everything ok.

  • Catalyst 2950 / ip dhcp-server

    Hello,
    who can explain the use of ip dhcp-server on Catalyst 2950?
    cat2950-03(config)#ip dhcp-server ?
    Hostname or A.B.C.D IP address or Name of DHCP server
    The "Catalyst 2950 and 2955 Cisco IOS Commands":
    http://www.cisco.com/univercd/cc/td/doc/product/lan/cat2950/12122ea2/2950cr/2950cr.pdf
    does not list that command.
    Is it the same as "ip helper-address xxx.xxx.xxx.xxx" without forwarding the other protocols like dns, netbios, and so in or does it configure the ios dhcp-server ( that should not be included on cat2950 - as far as I know)
    Greetings from Germany
    Sven

    Looks like it configures a remote DHCP server.
    cat2950-03(config)#ip dhcp-server ?
    Hostname or A.B.C.D IP address or Name of DHCP server
    So, say you have a DHCP server address of 10.34.1.1, the command would be
    cat2950-03(config)#ip dhcp-server 10.34.1.1
    That way the hosts on the switch will now where to send the requests for an IP address. Kinda like a Gateway address.
    Just my thoughts, Please rate if this helps
    Scott

  • Cisco ISE and Catalyst 2950

    Hello!
    Please, could you help me? Is it possible to install ISE on Catalyst 2950? In Component Compatibility Guide
    http://www.cisco.com/en/US/docs/security/ise/1.0.4/compatibility/ise104_sdt.html
    Catalyst 2950 only support 802.1X and VLAN.
    At first I need to know about VLAN change(from resticted to corporate). Is Catalyst 2950 support it?
    Thaks for help!

    this would let both user and machine authenticate. for"5434Endpoint conducted several failed authentications of the same scenario" check  Suppress Anomalous Clients option.  This issue comes in to picture when endpoint attempts a couple of failed authentications and if Suppress Anomalous Clients option with Reject Requests After Detection is enabled then  ISE Policy nodes protect themselves from overwhelming numbers of authentication requests by sending an immediate reject for suppressed clients as opposed to processing all the steps in a normal authentication. So if that user did some authentication failure, he will be locked for 1 hours (bydefault).

  • Cluster Management Software on Catalyst 2950

    Hi There,
    I was wondering if anyone would be kind enough to provide me with some help on getting the CMS software running on a Cisco Catalyst 2950 Switch. I have followed all the instructions I could find on getting the software to load from the Switch, but it will not load. Can anyone help me?
    Thank you in advance.
    John Grikes
    [email protected]

    You can start from: http://www.cisco.com/warp/public/473/59.html

  • Catalyst 2950 Switch flash_init error

    Hi Everyone,
    I'm new to Cisco products and have a small home lab set up. I have a Catalyst 2950 switch that I would like to restore to factory defaults. Here is the issue I'm having and can't figure out.
    I pull the power, telnet into the console port, hold the mode button and restore power. The boot loader (Version 12.1(11r) starts and says the usual message the system was interrupted prior to flash initialization (Paraphrasing here)
    I get to the switch: command line, enter flash_init. Flash states it initialized and then all I get is a < with an underscore under it prompt. Anything I try to type comes up as bizarre characters and I can not get back to a switch: prompt unless I reboot the switch manually. Unsure of what to do here.
    Thanks in advance!
    -Matt
    Telnet session:
    C2950 Boot Loader (C2950-HBOOT-M) Version 12.1(11r)EA1, RELEASE SOFTWARE (fc1)
    Compiled Mon 22-Jul-02 18:57 by antonino
    WS-C2950T-24 starting...
    Base ethernet MAC Address: 00:06:52:bb:c9:40
    Xmodem file system is available.
    The system has been interrupted prior to initializing the
    flash filesystem.  The following commands will initialize
    the flash filesystem, and finish loading the operating
    system software:
        flash_init
        load_helper
        boot
    switch: flash_init
    Initializing Flash...
    flashfs[0]: 4 files, 2 directories
    flashfs[0]: 0 orphaned files, 0 orphaned directories
    flashfs[0]: Total bytes: 7741440
    flashfs[0]: Bytes used: 3726848
    flashfs[0]: Bytes available: 4014592
    flashfs[0]: flashfs fsck took 7 seconds.
    ...done initializing flash.
    Boot Sector Filesystem (bs:) installed, fsid: 3
    Parameter Block Filesystem (pb:) installed, fsid: 4
    õíííííí   <---These characters appear no matter what keys I hit.

    Hi mattymattlynch
    Check the workaround on the following documents:
    http://www.cisco.com/c/en/us/support/docs/switches/catalyst-2950-series-switches/41845-192.html
    http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst2950/software/release/12-1_22_ea11x/configuration/guide/scg/swtrbl.html
    If no luck , the flash might be corrupted and requires a replacement.
    Hope this helps
    -Randy-

  • Cisco Catalyst 2950/2960/3750 Multicast Traffic Preference

    Hello all,
    we, as a student company act as an ISP for university dormitories. We would like to (if it's possible) deploy QoS to prefer multicast traffic over all other types of traffic. 
    Devices used in network:
    Acces layer: Cisco Catalyst 2950,  12.1(22)EA14
    Dristribution layer: Cisco Catalyst 2960G, 12.2(58)SE1 
    Core layer: Cisco Catalyst 3750G, 12.2(52)SE
    Do you see any possibility to solve this with these devices? We have almost no experience with QoS, therefore any help would be greatly appreciated. 
    Thanks in advance.

    Disclaimer
    The Author of this posting offers the information contained within this posting without consideration and with the reader's understanding that there's no implied or expressed suitability or fitness for any purpose. Information provided is for informational purposes only and should not be construed as rendering professional advice of any kind. Usage of this posting's information is solely at reader's own risk.
    Liability Disclaimer
    In no event shall Author be liable for any damages whatsoever (including, without limitation, damages for loss of use, data or profit) arising out of the use or inability to use the posting's information even if Author has been advised of the possibility of such damage.
    Posting
    Hmm, I think it should be doable although the 2950s, if non-E variants, are especially weak in QoS features.  I.e. those might create some issues.
    With the 2960G and 3750G, you often will create problems when you enable QoS because QoS, by default, allocates its buffers resources for 4 egress queues per port rather than using all for 1 egress queue per port.  However, this can be countered by QoS parameter tuning, but that takes some QoS expertize to match to your traffic and your overall QoS policy.

  • Trunking Catalyst 2950 to Catalyst 3750 problem

    I cannot seem to figure out how to trunk a catalyst 3750 to a Catalyst 2950.
    I've set
    3750(config)#interface fastethernet 1/0/2
    switchport mode trunk
    switchport trunk encapsulation dot1q
    BUT my Catalyst 2950 does not offer the "switchport trunk encapsulation dot1q" command
    My 2950 is running IOS version 12.1(20)EA1a
    is there a work around for this situation. Our network still employs a bunch of these 2950's.

    The Catalyst 2950 series can only do 802.1Q trunking. It's the default, and only, choice. So there's no need to specify it when trunking.
    In fact, since you don't have a choice of which encapsulation to use, there's no need for a "switchport trunk encapsulation" command. Which is why it's missing from the Cat2950 switch IOS.
    This took me by surprise too, when I first transitioned out of the 3500XL series into 2950 and 3550 switches.

  • POST error Catalyst 2950

    I have a Catalyst 2950 series 12 prt. switch. When the switch is booting I receive the following error: "00:00:13: POST: Packet DA mismatch on port: 9"
    What does this message means? Can I still use this port?
    Kind regards,

    This is part of the power on self test(POST).
    The switch sets the interface to loopback and sends
    a packet. If anything is wrong or changed with
    the packet then you get an error. In this case
    the DA (destination address) was changed on
    the received packet. I assume since this is a
    switch they are referring to the layer2 address.
    I would think this would indicate a possible hardware
    failure.

  • IP Accounting on catalyst 2950

    Hi all,
    Is there a way to find out traffic information from source IP to destination IP, like ip accounting used on routers, on the catalyst 2950 switch. My switch has the standard image.
    Also what performance impact would it have on the switch, if possible to implement.
    Thanks,
    George

    Hi dukenukem,
    no there is no way of interpreting flow information that way on a c2950. A c2950 is a L2 Device. Normally it doesn't really care about ip adresses.
    Regards,
    Sebastian

  • DHCP on Cisco Catalyst 2950 Switch

    Hello
    I need to configure my cisco catalyst 2950 series switch in order to act as DHCP server for devices connected to its ports.
    Please say me, how to do that ?
    Thank you
    Narek

    Please find the sample DHCP configuration for one of the VLANs.
    Interface Vlan1
    description Cisco DHCP
    ip address 10.10.2.1 255.255.255.0
    ip dhcp pool cisco
    network 10.10.2.0 255.255.255.0
    default-router 10.10.2.1
    domain-name mydomain.com
    dns-server 10.10.2.10
    netbios-name-server 10.10.2.15
    lease 7
    A 24 hour lease is the default if left out and the netbios-name-server is WINS in the Windows world.
    If you want to use DHCP server for other VLANs as well create similar DHCP pools and assign the DG to the corresponding VLAN interface IP.
    HTH, rate if it does
    Narayan

  • CATALYST 2950 SERIES - CLEAR OPT TABLE & DISABLE CASH

    I have 2 cisco switches model - catalyst 2950 series, i recently had an network issue regarding an ip conflict with one of my member servers, after being on the phone with microsoft support for 6 days, we were able to resolve the problem by locating the correct mac address and clearing the "OPT table on the switches" by unplugging and replugging the power cord. In order to prevent this from happening again, Microsoft had asked me to contact cisco and ask the following questions, " Are these swiches managable via the gui?  and we also need to make sure that the "Arp Cash is disabled on the switches" can anyone help in this matter?  Thanks in advance.

    Hi Arrowext289,
    Thank you for your question.  However the Small Business Support Community is limited to Cisco Small Business Products.
    Your question below relates to a Cisco Classic Product which our community would not be able to help you with.
    The best area for you to post your question would be at the Cisco NetPro forums switching area located here: https://supportforums.cisco.com/community/netpro/network-infrastructure/switching
    Best regards,
    Cindy
    Cindy Toy
    Small Business Community Manager
    Customer Advocacy
    Cisco Systems, Inc.
    www.cisco.com/go/smallbizsupport