Catalyst 2960 - IBM/Cisco IGESM - Trunk port configuration
Good day all!
I am new in Cisco world and try to configure a trunk between a Catalyst 2960 switch and a IBM Blade Center IGESM switch (manifactured by Cisco).
Unfortunately, it seems that the network traffic doesn't cross the trunk link.
I have followed (at least, I think so) the instructions given on the different Cisco documentation papers but I can't find the mistake in my configuration (lack of experience :-( !).
Both switches are using IOS. 2960 uses IOS 12.2(25)FX and IGESM uses IOS 12.2(22)EA8.
The ports are connected through a cross-over cable Cat5e.
Please find below the configuration for each ports:
Catalyst 2960:
Name: Gi0/1
Switchport: Enabled
Administrative Mode: trunk
Operational Mode: trunk
Administrative Trunking Encapsulation: dot1q
Operational Trunking Encapsulation: dot1q
Negotiation of Trunking: On
Access Mode VLAN: 200 (Workstation VLAN)
Trunking Native Mode VLAN: 200 (Workstation VLAN)
Administrative Native VLAN tagging: enabled
Voice VLAN: none
Administrative private-vlan host-association: none
Administrative private-vlan mapping: none
Administrative private-vlan trunk native VLAN: none
Administrative private-vlan trunk Native VLAN tagging: enabled
Administrative private-vlan trunk encapsulation: dot1q
Administrative private-vlan trunk normal VLANs: none
Administrative private-vlan trunk private VLANs: none
Operational private-vlan: none
Trunking VLANs Enabled: 1,99,200
Pruning VLANs Enabled: 2-1001
Capture Mode Disabled
Capture VLANs Allowed: ALL
Protected: false
Unknown unicast blocked: disabled
Unknown multicast blocked: disabled
Appliance trust: none
IBM/Cisco IGESM:
Name: Gi0/20
Switchport: Enabled
Administrative Mode: trunk
Operational Mode: trunk
Administrative Trunking Encapsulation: dot1q
Operational Trunking Encapsulation: dot1q
Negotiation of Trunking: On
Access Mode VLAN: 200 (Workstation VLAN)
Trunking Native Mode VLAN: 200 (Workstation VLAN)
Voice VLAN: none
Administrative private-vlan host-association: none
Administrative private-vlan mapping: none
Administrative private-vlan trunk native VLAN: none
Administrative private-vlan trunk encapsulation: dot1q
Administrative private-vlan trunk normal VLANs: none
Administrative private-vlan trunk private VLANs: none
Operational private-vlan: none
Trunking VLANs Enabled: 1,99,200
Pruning VLANs Enabled: 2-1001
Capture Mode Disabled
Capture VLANs Allowed: ALL
Protected: false
Unknown unicast blocked: disabled
Unknown multicast blocked: disabled
Appliance trust: none
For my test, I try to ping a blade (connected to IGESM) in VLAN 200 from a workstation connected to Catalyst 2960 (in VLAN 200 too). From a network anaylser (ethereal), I can see the ARP broadcast from each side but none are going across the trunk link.
I am a bit lost about this problem and would be grateful for any assistance in solving it!
Many, many thanks in advance for your time!
Best regards,
Fabian
Hi Glen!
Both switches (Catalyst 2960 & IGESM) are brand new and most ports are still reflecting manufacturer's default configuration. Vlan 2 is the default native vlan for IGESM ports (excluding ports used for switch management which use vlan 1 as most Cisco switches).
I changed the native vlan for g0/5 on IGESM to 200. Now, ports g0/5 (access mode) and g0/20 (trunk mode) are on native vlan 200. On g0/5 is installed Windows 2003 instance (firewall disabled). The only purpose is to receive and send ping request to test connectivity.
My workstation is connected to 2960 switch on port fa0/1 (please find the configuration below). I can successfully ping other vlan 200 machines connected on the same switch. For testing purpose, I try to ping the blade machine connected on port g0/5 on IGESM.
Configuration of fa0/1:
Name: Fa0/1
Switchport: Enabled
Administrative Mode: dynamic auto
Operational Mode: static access
Administrative Trunking Encapsulation: dot1q
Operational Trunking Encapsulation: native
Negotiation of Trunking: On
Access Mode VLAN: 200 (Workstation VLAN)
Trunking Native Mode VLAN: 200 (Workstation VLAN)
Administrative Native VLAN tagging: enabled
Voice VLAN: none
Administrative private-vlan host-association: none
Administrative private-vlan mapping: none
Administrative private-vlan trunk native VLAN: none
Administrative private-vlan trunk Native VLAN tagging: enabled
Administrative private-vlan trunk encapsulation: dot1q
Administrative private-vlan trunk normal VLANs: none
Administrative private-vlan trunk private VLANs: none
Operational private-vlan: none
Trunking VLANs Enabled: ALL
Pruning VLANs Enabled: 2-1001
Capture Mode Disabled
Capture VLANs Allowed: ALL
Protected: false
Unknown unicast blocked: disabled
Unknown multicast blocked: disabled
Appliance trust: none
Is there any other information I could provide to better help you to understand the configuration?
Cheers!
Fabian
Similar Messages
-
Catalyst 6500 Block Switching Between Trunk Port
Hello all,
I have a Catalyst 6509-E with SUP2T and a WS-68xx series SFP line card. On this line card I will have 5 trunk connections going to ME3400 4 port access switches. There is one tagged VLAN allowed on all trunk ports and it is the same across them all. I need to have one trunk connection be allowed to switch to all ports within this VLAN and the remaining 3 ports be denied to switch between eachother. The remaining three ports would only be able to switch to the primary trunk port.
For informational purposes I want to point out that the downstream ME3400 access switches are performing QinQ on each connection so that when the traffic reaches the 6509 it will be double tagged.
Traditionally I have been able to do this on 12 port ME3400s using the built in UNI/NNI structure and on ME3800/3600 switches using EVCs and the "split-horizon" keyword on the bridge domain. However, the 6500 doesn't seem to support either one of these commands.
Does anyone have any ideas on how to accomplish this?Duplicate posts.
Go here: https://supportforums.cisco.com/thread/2261414 -
Catalyst 6500 Block Switching Between Trunk Ports
Hello all,
I have a Catalyst 6509-E with SUP2T and a WS-68xx series SFP line card. On this line card I will have 5 trunk connections going to ME3400 4 port access switches. There is one tagged VLAN allowed on all trunk ports and it is the same across them all. I need to have one trunk connection be allowed to switch to all ports within this VLAN and the remaining 3 ports be denied to switch between eachother. The remaining three ports would only be able to switch to the primary trunk port.
For informational purposes I want to point out that the downstream ME3400 access switches are performing QinQ on each connection so that when the traffic reaches the 6509 it will be double tagged.
Traditionally I have been able to do this on 12 port ME3400s using the built in UNI/NNI structure and on ME3800/3600 switches using EVCs and the "split-horizon" keyword on the bridge domain. However, the 6500 doesn't seem to support either one of these commands.
Does anyone have any ideas on how to accomplish this?I'm really not all that savvy on private VLANs but I did look at them as an option. Would they be affective on trunk ports? Most config examples I have seen have shown them applied on access ports.
Can't see switchport protected:
6509(config-if)#switchport protected
^
% Invalid input detected at '^' marker. -
Troubleshooting Fiber Connection on a Catalyst 2960
I am trying to test my fiber connectivity on a Catalyst 2960 before I deploy it. So what I thought I would do is connect it to another switch in my office with a open port for the fiber connection. The other switch is a Catalyst 3560G. Here are the port configurations:
interface GigabitEthernet0/2
switchport trunk allowed vlan 1,100
switchport mode trunk
macro description cisco-switch
interface GigabitEthernet0/25
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 1,100
switchport mode trunk
The first one is the catalyst 2960 and the 3560G is the second.
When you show the interface for each of these it shows that it recognizes the media but the line protocal and the GigbitEthernet Port is down.
Any Ideas?Sorry... a fiber optic cable with a connector on each end.
To aid in troubleshooting, many times we loopback the signal back to the originating device. An optical loopback is just connecting the transmit (Tx) to the receive (Rx).
The multimode SFP/GBIC transceiver you are using will allow you to directly connect the Transmit and Receive ports without damage to the unit. This should provide you with a green link LED.
If so, then you can reconnect your fibers and loopback (connect the two fibers together) at the far end of the fiber link (use an optical adapter) and see if you get a green LED. -
Cisco VLAN Trunking Protocol Vulnerability
I have got a cisco 2821 model router with a c2800nm-advipservicesk9-mz.151-2.T4 IOS, and was reported with 'Cisco VLAN Trunking Protocol Vulnerability'.
Though the device is in server mode, I do not have any domain name or trunk port configured.
Is my device really vulnerable? If yes, whats next?Hi Alex,
for the trunk port on Catalyst on port GE 1/0/45, we need to enable the trunk and for on encapsulation dot1q because this catalyst model is ISL capable also and the SF300 working only with Dot1q Encapsultion
The configuration on catalyst should :
#config terminal
#interface Gi 1/0/45
# switchport encapsulation
#switchport trunk encapsulation dot1q
#switchport mode trunk
#switchport trunk allowed vlan 101-103
#spanning-tree portfast
For SF300 the port trunk it looks fine but for the port where the PC should receive an IP address
#interface fastethernet29
#switchport mode access
#switchport ccess vlan 103
Please let me know after this configuration
Thanks
Mehdi
Please rate or mark as answered to help other Cisco Customers -
Catalyst 2960 and SGE500 switches
Hi,
Can we on the same network use Cisco Catalyst 2960 and Cisco SGE500 switches and share the same VLANs ?Hi,
I didn't find VLAN support in key feautures of SGE500 but I'm sure it is there. For VLAN sharing you must configure trunk between switches. The number of VLAN must be the same (exluded some cases).
For sharing VLAN information (VLAN count, names etc) the switches must support VTP protocol, not sure that SGE500 support it. But VTP is not necessary for trunking between switches. -
Hi
I am stacking 6 Catalyst 2960 SF Series PoE 48 ports, I am using the Bladestack cable. I plug it in from 1 to 2 on all the switches. If I look at the lights it shows 4 in on group and 2 in another. If I do a show switch detail it shows the following
Switch/Stack Mac Address : 44ad.d982.a100
H/W Current
Switch# Role Mac Address Priority Version State
1 Member 5006.0425.7e00 1 1 Ready
*2 Master 44ad.d982.a100 1 1 Ready
3 Member 5006.0435.bc00 1 1 Waiting
4 Member 5006.04d8.7000 1 1 Ready
Stack Port Status Neighbors
Switch# Port 1 Port 2 Port 1 Port 2
1 Down Ok None 2
2 Ok Ok 4 1
4 Down Ok None 2Hi , i think only four 2960 SF switches can be stacked into a singe logical switch.
Please refer the link , hope this helps:
http://www.cisco.com/en/US/prod/collateral/switches/ps5718/ps6406/white_paper_c11-578928.html -
I have a router to a 3550 switch feeding in a star toplogy one 2950 off each port. I have port protprected on the ports of each of the 2950s. The question is can I do port protected on all my trunk ports except the uplink port on the 3550? I am wanting to stop any user on the network from seeing another. My other option is to do a vlan per switch but would perfer not to bring down the network as it is already live and in heavy usage.
Thank you for your help in advance.Yes, you can enable protected mode on trunk ports
Configuring Protected Ports
Some applications require that no traffic be forwarded between ports on the same switch so that one neighbor does not see the traffic generated by another neighbor. In such an environment, the use of protected ports ensures that there is no exchange of unicast, broadcast, or multicast traffic between these ports on the switch.
Protected ports have these features:
•A protected port does not forward any traffic (unicast, multicast, or broadcast) to any other port that is also a protected port. Data traffic cannot be forwarded between protected ports at Layer 2; only control traffic, such as PIM packets, is forwarded because these packets are processed by the CPU and forwarded in software. All data traffic passing between protected ports must be forwarded through a Layer 3 device.
•Forwarding behavior between a protected port and a nonprotected port proceeds as usual.
•Protected ports are supported on 802.1Q trunks.
link:
http://www.cisco.com/en/US/docs/switches/lan/catalyst2950/software/release/12.1_20_ea2/configuration/guide/swtrafc.html#wp1158863
HTH -
Bandwidth monitoring on a Catalyst 2960
Hello all, I'm working with two Catalyst 2960 switches and I would like to know if there is a way to monitor bandwidth on individual ports. Ideally I would like to have one graph showing a bandwidth usage reading on each port. I tried using the Network Assistant to accomplish this, but I was only able to view one port at a time. I also tried using a traffic graphing program from Paessler, but a MIB file is needed to allow the program to connect to the switch. When I ran a search on the network management page the 2960 was not on the list for MIB supported products. Is this type of graph possible to do? Or is there a more effective way to accomplish what I would like to do. Any ideas or suggestions would be helpful.
Hi, we have just swapped all our avaya switches with catalyst 2960 (12, 24 and 48 ports) and 3750 (48 ports with 10gig module).
How do I find what port I should monitor for bandwith graphs?
Target[10.0.0.22_loc1]: 1:@10.0.0.22: -
Error in switch ports POE model, "Cisco Catalyst 2960S-24PS-L Switch"
I have problem with the poe switch Cisco Catalyst 2960S-24PS-L posts does not respond, and me the following error resporta was t
%PLATFORM_ENV-3-ILP_PORT_POST_ERR: %s can’t be brought up because it failed POST
in Inline Power test.
he source of that error and what are the possible causesHey Dustin,
Device needs to be RMA'ed. The inline power supply has failed.
HTH.
Regards,
RS. -
802.1x on Cisco Catalyst 2960
I am trying to enable 802.1x on one of
the switchports of the Cisco Catalyst
2960:
C2960#sh run | i radius
aaa authentication login test group radius local
aaa authentication dot1x default group radius
radius-server host 10.250.97.26 auth-port 1812 acct-port 1813
radius-server source-ports 1645-1646
radius-server key 123456
C2960#sh run | i dot
aaa authentication dot1x default group radius
dot1x system-auth-control
dot1x guest-vlan supplicant
dot1x critical eapol
C2960#conf t
Enter configuration commands, one per line. End with CNTL/Z.
C2960(config)#int g0/14
C2960(config-if)#dot1x ?
% Unrecognized command
C2960(config-if)#dot1x
As you can see, I can not enable 802.1x
at the interface level. The code is am running is 12.2.25SEE4:
Switch Ports Model SW Version SW Image
* 1 24 WS-C2960G-24TC-L 12.2(25)SEE4 C2960-LANBASEK9-M
System image file is "flash:c2960-lanbasek9-mz.122-25.SEE4.bin"
According to Cisco, this image supports
802.1x. Why can't enable it at the
interface level?
Can someone help me out? Thanks.some additional info:
C2960#sh dot1x all
Sysauthcontrol Enabled
Dot1x Protocol Version 2
Critical Recovery Delay 100
Critical EAPOL Enabled
C2960# -
Guys,
Can the IBM BladeCenter chassis be used to connect the blade servers to different subnets (different physical segments also)?? The specific config that I have is using the Cisco IGESM switches.
Thanks guys.Hello,
not sure if this is what you are asking, but I think you need an external router for that, that is, you can configure the ports IGESM ports for different VLANs, but in order to route between the VLANs, you need a routing device.
Check the ´Cisco Systems Intelligent Gigabit Ethernet Switch Modules Software Configuration Guide´ in the link below, and consult the chapter ´Configuring Interface Characteristics´ (Figure 7-1):
http://www.cisco.com/application/pdf/en/us/guest/products/ps6294/c1067/ccmigration_09186a00805b60d4.pdf
Regards,
GP -
Catalyst 2960S-LPS-L PoE only on specific ports not working
Hi,
we have Catalyst 2960S-LPS-L (48 Ports) here which in general works fine.
If i connect a Cisco Access Point (2602), it´s powered up via PoE, but on some ports this is not working; it just doesn´t power up. The port configuration is exactly the same. I rebooted the switch, but still the same.
Any ideas how to troubleshoot this? Is it possible, that the PoE capability on some ports is just broken?
Thanks
HeinzHi,
it did all this, but there are no irregularities. IOS is version 152-1.E2
#sho post
Stored system POST messages:
Switch 1
POST: MA BIST : Begin
FC 1 MBIST Test Passed.
DP Sg1 MBIST Test Passed.
DP Xg1 MBIST Test Passed.
NI 1 MBIST Test Passed.
FC 0 MBIST Test Passed.
DP Sg0 MBIST Test Passed.
DP Xg0 MBIST Test Passed.
NI 0 MBIST Test Passed.
UPB MBIST Test Passed.
POST: MA BIST : End, Status Passed
POST: TCAM BIST : Begin
POST: TCAM BIST : End, Status Passed
POST: Inline Power Controller Tests : Begin
POST: Inline Power Controller Tests : End, Status Passed
POST: Thermal, Fan Tests : Begin
POST: Thermal, Fan Tests : End, Status Passed
POST: PortASIC Stack Port Loopback Tests : Begin
POST: PortASIC Stack Port Loopback Tests : End, Status Passed
POST: PortASIC Port Loopback Tests : Begin
POST: PortASIC Port Loopback Tests : End, Status Passed
POST: EMAC Loopback Tests : Begin
POST: EMAC Loopback Tests : End, Status Passed
#sho power inline
fti-mco01-ssw01#sho power inline
Module Available Used Remaining
(Watts) (Watts) (Watts)
1 370.0 84.7 285.3
2 370.0 56.7 313.3
3 370.0 169.4 200.6
Interface Admin Oper Power Device Class Max
(Watts)
Gi1/0/1 auto on 6.3 IP Phone 7940 n/a 30.0
Gi1/0/2 auto off 0.0 n/a n/a 30.0
Gi1/0/3 auto off 0.0 n/a n/a 30.0
Gi1/0/4 auto off 0.0 n/a n/a 30.0
Gi1/0/5 auto off 0.0 n/a n/a 30.0
Gi1/0/6 auto off 0.0 n/a n/a 30.0
Gi1/0/7 auto off 0.0 n/a n/a 30.0
Gi1/0/8 auto off 0.0 n/a n/a 30.0
Gi1/0/9 auto off 0.0 n/a n/a 30.0
Gi1/0/10 auto on 6.3 IP Phone 7912 n/a 30.0
Gi1/0/11 auto off 0.0 n/a n/a 30.0
Gi1/0/12 auto off 0.0 n/a n/a 30.0
Gi1/0/13 auto on 6.3 IP Phone 7940 n/a 30.0
Gi1/0/14 auto off 0.0 n/a n/a 30.0
Gi1/0/15 auto off 0.0 n/a n/a 30.0
Gi1/0/16 auto off 0.0 n/a n/a 30.0
Gi1/0/17 auto off 0.0 n/a n/a 30.0
Gi1/0/18 auto on 6.3 IP Phone 7940 n/a 30.0
Gi1/0/19 auto off 0.0 n/a n/a 30.0
Gi1/0/20 auto on 6.3 IP Phone 7940 n/a 30.0
Gi1/0/21 auto on 6.3 IP Phone 7940 n/a 30.0
Gi1/0/22 auto off 0.0 n/a n/a 30.0
Gi1/0/23 auto on 6.3 IP Phone 7960 n/a 30.0
Gi1/0/24 auto off 0.0 n/a n/a 30.0
Gi1/0/25 auto on 6.3 IP Phone 7940 n/a 30.0
Gi1/0/26 auto off 0.0 n/a n/a 30.0
Gi1/0/27 auto off 0.0 n/a n/a 30.0
Gi1/0/28 auto off 0.0 n/a n/a 30.0
Gi1/0/29 auto off 0.0 n/a n/a 30.0
Gi1/0/30 auto off 0.0 n/a n/a 30.0
Gi1/0/31 auto off 0.0 n/a n/a 30.0
Gi1/0/32 auto off 0.0 n/a n/a 30.0
Gi1/0/33 auto off 0.0 n/a n/a 30.0
Gi1/0/34 auto off 0.0 n/a n/a 30.0
Gi1/0/35 auto on 6.3 IP Phone 7960 n/a 30.0
Gi1/0/36 auto off 0.0 n/a n/a 30.0
Gi1/0/37 auto on 6.3 IP Phone 7960 n/a 30.0
Gi1/0/38 auto on 15.4 AIR-SAP2602I-E-K9 3 30.0
Gi1/0/39 auto off 0.0 n/a n/a 30.0
Gi1/0/40 auto off 0.0 n/a n/a 30.0
Gi1/0/41 auto off 0.0 n/a n/a 30.0
Gi1/0/42 auto on 6.3 IP Phone 7912 n/a 30.0
Gi1/0/43 auto off 0.0 n/a n/a 30.0
Gi1/0/44 auto off 0.0 n/a n/a 30.0
Gi1/0/45 auto off 0.0 n/a n/a 30.0
Gi1/0/46 auto off 0.0 n/a n/a 30.0
Port G1/0/44 is not delivering PoE; Port G1/0/38 has exactly the same configuration and it´s working. -
VLAN trunking from Cisco Catalyst 3750 to Cisco SF300-48P issue and related
Hello expert,
I'm having difficulties to configure VLAN trunking between Cisco Catalyst 3750 switch with Cisco SF300-48P switch and my workstation unable to get any DHCP IP from our DHCP server via Cisco SF300-48P switch. Below is the snippet of configuration on both switches:
[Cisco Catalyst 3750 Switch]
interface GigabitEthernet1/0/45
description NCC-CC-1stFlr
no switchport trunk encapsulation dot1q
no switchport trunk allowed vlan 101-103
spanning-tree portfast
[Cisco SF300-48P Switch]
interface fastethernet48
spanning-tree link-type point-to-point
switchport trunk allowed vlan add 101-103
macro description switch
!next command is internal.
macro auto smartport dynamic_type switch
interface fastethernet29
switchport mode general
switchport general allowed vlan add 103 tagged
switchport general pvid 103
Are these are correct? Kindly advice!
Thank you very much!
Regards,
AlexHi Alex,
for the trunk port on Catalyst on port GE 1/0/45, we need to enable the trunk and for on encapsulation dot1q because this catalyst model is ISL capable also and the SF300 working only with Dot1q Encapsultion
The configuration on catalyst should :
#config terminal
#interface Gi 1/0/45
# switchport encapsulation
#switchport trunk encapsulation dot1q
#switchport mode trunk
#switchport trunk allowed vlan 101-103
#spanning-tree portfast
For SF300 the port trunk it looks fine but for the port where the PC should receive an IP address
#interface fastethernet29
#switchport mode access
#switchport ccess vlan 103
Please let me know after this configuration
Thanks
Mehdi
Please rate or mark as answered to help other Cisco Customers -
Cisco SG300-28 / SGE2000 / Catalyst 2960
Hello everyone,
I'm looking for switch to accompany Cisco ASA 5520 in data center, with 20+ GE ports and no need for PoE.
I would like to understand the difference between Cisco SG300-28, Cisco SGE2000 and Cisco Catalyst 2960, 2960-C and 2960-S Series (except specific number of ports). As far as I can see the Cisco SGE2000 has 4x SFP and is stackable unlike the SG300 with 2x miniGBIC/SFP, but not much else. Cisco Catalyst 2960 series offers some additional features like USB storage, but I can't imagine I will need that.
Any suggestions?
Thank you
DanHello everyone,
I'm looking for switch to accompany Cisco ASA 5520 in data center, with 20+ GE ports and no need for PoE.
I would like to understand the difference between Cisco SG300-28, Cisco SGE2000 and Cisco Catalyst 2960, 2960-C and 2960-S Series (except specific number of ports). As far as I can see the Cisco SGE2000 has 4x SFP and is stackable unlike the SG300 with 2x miniGBIC/SFP, but not much else. Cisco Catalyst 2960 series offers some additional features like USB storage, but I can't imagine I will need that.
Any suggestions?
Thank you
Dan
Maybe you are looking for
-
Dear Expert, Currently i am facing a strange issue regarding email notification and I am not sure where was the problem stuck even I have raised a message to SAP but till no any success. In our case we are getting a notification and approval mail in
-
Fonr size change in Webdnypro for ABAP
Hi, We have a requirement to change the font size of UI elements in WDA application which is integrated in Portal via web page composer. To alloborate more, in web page composer WDA application is called as <iframe>http://<host>:<port>/bc.../<webdnyp
-
How does Time Machine handle alias files on the backup volume?
I have been trying to find some info on how Time Machine handles alias files on the backup volume, but can't find anything on that topic. Neither here in this discussion or at the Apple support pages. My concern is if an alias file on the backup volu
-
SQL question - please help!
Hi, I am working on a SQL, please help ms with the question below .... thanks (1)Increase by 10% salary of these captain pilots who have traveled more than 800,000 miles. Routes | | Flights | |Pilots | | | | | | #routeID | | #flightNO | |#pilotID | d
-
HttpURLConnection.getInputStream FileNotFoundException
Hy all, when i try to accessa business servlet from a presentation serlvet i get the folowing exception at java.lang.Throwable.fillInStackTrace(Native Method) at java.lang.Throwable.fillInStackTrace(Compiled Code) at java.lang.Throwable.<init>(Compil