Catalyst 2960 POE Consumption
Hi,
I've been advised by a third party vendor to put my catalyst 2960 poe switch into consumption mode. Is that possible with this model?
Thanks,
This is what you can do:
Supported Protocols and Standards
The switch uses these protocols and standards to support PoE:
•CDP with power consumption—The powered device notifies the switch of the amount of power it is consuming. The switch does not reply to the power-consumption messages. The switch can only supply power to or remove power from the PoE port.
•Cisco intelligent power management—The powered device and the switch negotiate through power-negotiation CDP messages for an agreed power-consumption level. The negotiation allows a high-power Cisco powered device, which consumes more than 7 W, to operate at its highest power mode. The powered device first boots up in low-power mode, consumes less than 7 W, and negotiates to obtain enough power to operate in high-power mode. The device changes to high-power mode only when it receives confirmation from the switch.
High-power devices can operate in low-power mode on switches that do not support power-negotiation CDP.
Cisco intelligent power management is backward-compatible with CDP with power consumption; the switch responds according to the CDP message that it receives. CDP is not supported on third-party powered devices; therefore, the switch uses the IEEE classification to determine the power usage of the device.
•IEEE 802.3af—The major features of this standard are powered-device discovery, power administration, disconnect detection, and optional powered-device power classification. For more information, see the standard.
•IEEE 802.3at (Catalyst 2960-S only)—This PoE+ standard supports all the features of 802.1af and increases the maximum power available on each PoE port from 15.4 W to 30 W.
Powered-Device Detection and Initial Power Allocation
The switch detects a Cisco pre-standard or an IEEE-compliant powered device when the PoE-capable port is in the no-shutdown state, PoE is enabled (the default), and the connected device is not being powered by an AC adaptor.
After device detection, the switch determines the device power requirements based on its type:
•A Cisco pre-standard powered device does not provide its power requirement when the switch detects it, so a Catalyst 2960 switch allocates 15.4 W as the initial allocation for power budgeting; a Catalyst 2960-S switch allocates 30 W (PoE+).
The initial power allocation is the maximum amount of power that a powered device requires. The switch initially allocates this amount of power when it detects and powers the powered device. As the switch receives CDP messages from the powered device and as the powered device negotiates power levels with the switch through CDP power-negotiation messages, the initial power allocation might be adjusted.
•The switch classifies the detected IEEE device within a power consumption class. Based on the available power in the power budget, the switch determines if a port can be powered. Table 12-1 lists these levels.
Table 12-1 IEEE Power Classifications
Class
Maximum Power Level Required from the Switch
0 (class status unknown)
15.4 W
1
4 W
2
7 W
3
15.4 W
4
30 W (Catalyst 2960-S only)
Similar Messages
-
Catalyst 2960 POE Switch Consumption Mode
Hi,
I'm curious how I can configure a 2960 to function in POE consumption mode. I know with other switches you can explicitly configure them to only give devices the power they consume and not power based on what class the belong to.
I have read that the following command should do what I need:
power inline consumption wattage
...although I would have thought I wouldn't need to specify the wattage if I wanted the device to tell the switch how much power it needs.
ThanksHi,
The "power inline consumption" command is a global config that applies to the entire switch to override the default:
from the command reference guide
Use the power inline consumption global or interface configuration command on the switch stack or on a standalone switch to override the amount of power specified by the IEEE classification for the device by specifying the wattage used by each powered device. Use the no form of this command to return to the default power setting.
http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst3750e_3560e/software/release/12-2_44_se/command/reference/cr1/cli1.html#wp8821622
HTH -
SFP Mini-GBIC for Catalyst 2960
We are looking at getting the SFP Mini-GBIC from HP HP-J4858C. This transceiver module is Gigabit-SX-LC Mini-GBIC. Will this module work on our Catalyst 2960 PoE switches and will it also work using a MultiMode fiber?
I've used non-Cisco GBICs successfully in Cisco gear. In the event of a problem related to the link, the TAC MAY refer you back to the HP or suggest using a Cisco transceiver.
Running a multimode connection that close to the length limit is not the best idea but if that's all you have installed (and you can't get a single mode link installed) then it is what it is. A single mode GBIC WILL NOT operate over multimode fiber.
The high level specs cite distance but the real indicator of usability is better characterized by loss. As long as you getting adequate light levels at the receiver, you will be OK. Problem is, it's not easy to tell light levels (on a non-SMD type transceiver such as Leo suggested) without some relatively costly measurement equipment. -
Error in switch ports POE model, "Cisco Catalyst 2960S-24PS-L Switch"
I have problem with the poe switch Cisco Catalyst 2960S-24PS-L posts does not respond, and me the following error resporta was t
%PLATFORM_ENV-3-ILP_PORT_POST_ERR: %s can’t be brought up because it failed POST
in Inline Power test.
he source of that error and what are the possible causesHey Dustin,
Device needs to be RMA'ed. The inline power supply has failed.
HTH.
Regards,
RS. -
Catalyst 2960S-LPS-L PoE only on specific ports not working
Hi,
we have Catalyst 2960S-LPS-L (48 Ports) here which in general works fine.
If i connect a Cisco Access Point (2602), it´s powered up via PoE, but on some ports this is not working; it just doesn´t power up. The port configuration is exactly the same. I rebooted the switch, but still the same.
Any ideas how to troubleshoot this? Is it possible, that the PoE capability on some ports is just broken?
Thanks
HeinzHi,
it did all this, but there are no irregularities. IOS is version 152-1.E2
#sho post
Stored system POST messages:
Switch 1
POST: MA BIST : Begin
FC 1 MBIST Test Passed.
DP Sg1 MBIST Test Passed.
DP Xg1 MBIST Test Passed.
NI 1 MBIST Test Passed.
FC 0 MBIST Test Passed.
DP Sg0 MBIST Test Passed.
DP Xg0 MBIST Test Passed.
NI 0 MBIST Test Passed.
UPB MBIST Test Passed.
POST: MA BIST : End, Status Passed
POST: TCAM BIST : Begin
POST: TCAM BIST : End, Status Passed
POST: Inline Power Controller Tests : Begin
POST: Inline Power Controller Tests : End, Status Passed
POST: Thermal, Fan Tests : Begin
POST: Thermal, Fan Tests : End, Status Passed
POST: PortASIC Stack Port Loopback Tests : Begin
POST: PortASIC Stack Port Loopback Tests : End, Status Passed
POST: PortASIC Port Loopback Tests : Begin
POST: PortASIC Port Loopback Tests : End, Status Passed
POST: EMAC Loopback Tests : Begin
POST: EMAC Loopback Tests : End, Status Passed
#sho power inline
fti-mco01-ssw01#sho power inline
Module Available Used Remaining
(Watts) (Watts) (Watts)
1 370.0 84.7 285.3
2 370.0 56.7 313.3
3 370.0 169.4 200.6
Interface Admin Oper Power Device Class Max
(Watts)
Gi1/0/1 auto on 6.3 IP Phone 7940 n/a 30.0
Gi1/0/2 auto off 0.0 n/a n/a 30.0
Gi1/0/3 auto off 0.0 n/a n/a 30.0
Gi1/0/4 auto off 0.0 n/a n/a 30.0
Gi1/0/5 auto off 0.0 n/a n/a 30.0
Gi1/0/6 auto off 0.0 n/a n/a 30.0
Gi1/0/7 auto off 0.0 n/a n/a 30.0
Gi1/0/8 auto off 0.0 n/a n/a 30.0
Gi1/0/9 auto off 0.0 n/a n/a 30.0
Gi1/0/10 auto on 6.3 IP Phone 7912 n/a 30.0
Gi1/0/11 auto off 0.0 n/a n/a 30.0
Gi1/0/12 auto off 0.0 n/a n/a 30.0
Gi1/0/13 auto on 6.3 IP Phone 7940 n/a 30.0
Gi1/0/14 auto off 0.0 n/a n/a 30.0
Gi1/0/15 auto off 0.0 n/a n/a 30.0
Gi1/0/16 auto off 0.0 n/a n/a 30.0
Gi1/0/17 auto off 0.0 n/a n/a 30.0
Gi1/0/18 auto on 6.3 IP Phone 7940 n/a 30.0
Gi1/0/19 auto off 0.0 n/a n/a 30.0
Gi1/0/20 auto on 6.3 IP Phone 7940 n/a 30.0
Gi1/0/21 auto on 6.3 IP Phone 7940 n/a 30.0
Gi1/0/22 auto off 0.0 n/a n/a 30.0
Gi1/0/23 auto on 6.3 IP Phone 7960 n/a 30.0
Gi1/0/24 auto off 0.0 n/a n/a 30.0
Gi1/0/25 auto on 6.3 IP Phone 7940 n/a 30.0
Gi1/0/26 auto off 0.0 n/a n/a 30.0
Gi1/0/27 auto off 0.0 n/a n/a 30.0
Gi1/0/28 auto off 0.0 n/a n/a 30.0
Gi1/0/29 auto off 0.0 n/a n/a 30.0
Gi1/0/30 auto off 0.0 n/a n/a 30.0
Gi1/0/31 auto off 0.0 n/a n/a 30.0
Gi1/0/32 auto off 0.0 n/a n/a 30.0
Gi1/0/33 auto off 0.0 n/a n/a 30.0
Gi1/0/34 auto off 0.0 n/a n/a 30.0
Gi1/0/35 auto on 6.3 IP Phone 7960 n/a 30.0
Gi1/0/36 auto off 0.0 n/a n/a 30.0
Gi1/0/37 auto on 6.3 IP Phone 7960 n/a 30.0
Gi1/0/38 auto on 15.4 AIR-SAP2602I-E-K9 3 30.0
Gi1/0/39 auto off 0.0 n/a n/a 30.0
Gi1/0/40 auto off 0.0 n/a n/a 30.0
Gi1/0/41 auto off 0.0 n/a n/a 30.0
Gi1/0/42 auto on 6.3 IP Phone 7912 n/a 30.0
Gi1/0/43 auto off 0.0 n/a n/a 30.0
Gi1/0/44 auto off 0.0 n/a n/a 30.0
Gi1/0/45 auto off 0.0 n/a n/a 30.0
Gi1/0/46 auto off 0.0 n/a n/a 30.0
Port G1/0/44 is not delivering PoE; Port G1/0/38 has exactly the same configuration and it´s working. -
Hi
I am stacking 6 Catalyst 2960 SF Series PoE 48 ports, I am using the Bladestack cable. I plug it in from 1 to 2 on all the switches. If I look at the lights it shows 4 in on group and 2 in another. If I do a show switch detail it shows the following
Switch/Stack Mac Address : 44ad.d982.a100
H/W Current
Switch# Role Mac Address Priority Version State
1 Member 5006.0425.7e00 1 1 Ready
*2 Master 44ad.d982.a100 1 1 Ready
3 Member 5006.0435.bc00 1 1 Waiting
4 Member 5006.04d8.7000 1 1 Ready
Stack Port Status Neighbors
Switch# Port 1 Port 2 Port 1 Port 2
1 Down Ok None 2
2 Ok Ok 4 1
4 Down Ok None 2Hi , i think only four 2960 SF switches can be stacked into a singe logical switch.
Please refer the link , hope this helps:
http://www.cisco.com/en/US/prod/collateral/switches/ps5718/ps6406/white_paper_c11-578928.html -
CiscoWorks LMS3.0 doesn't know the 2960 PoE type
I have several PoE Catalyst 2960 WS-C2960-24PC-L
When I added them to CiscoWokrs I found out that it doesn't know WS-C2960-24PC-L type.
As a result they are unknown.
The list of installed applications:
1. LMS Portal 1.0.0
2. CiscoWorks Assistant 1.0.0
3. CiscoView 6.1.6
4. CiscoWorks Common Services 3.1.0
5. Integration Utility 1.7.0
6. Resource Manager Essentials 4.1.0
7. Campus Manager 5.0.0
8. Device Fault Manager 3.0.0
9. Internetwork Performance Monitor 4.0.0
How to add WS-C2960-24PC-L to the LMS?
As I understand I have to update Resource Manager Essentials. Which version should I install ?RME 4.1.1, Campus Manager 5.0.3
Check the doc:
http://www.cisco.com/en/US/docs/net_mgmt/ciscoworks_lan_management_solution/3.2/device_support/table/lms32sdt.html
I understand that is for device :
Cisco Catalyst 2960-24PC-L Switch
(WS-C2960-24PC-L)
with sysobject ID :1.3.6.1.4.1.9.1.950 -
Cisco SG300-28 / SGE2000 / Catalyst 2960
Hello everyone,
I'm looking for switch to accompany Cisco ASA 5520 in data center, with 20+ GE ports and no need for PoE.
I would like to understand the difference between Cisco SG300-28, Cisco SGE2000 and Cisco Catalyst 2960, 2960-C and 2960-S Series (except specific number of ports). As far as I can see the Cisco SGE2000 has 4x SFP and is stackable unlike the SG300 with 2x miniGBIC/SFP, but not much else. Cisco Catalyst 2960 series offers some additional features like USB storage, but I can't imagine I will need that.
Any suggestions?
Thank you
DanHello everyone,
I'm looking for switch to accompany Cisco ASA 5520 in data center, with 20+ GE ports and no need for PoE.
I would like to understand the difference between Cisco SG300-28, Cisco SGE2000 and Cisco Catalyst 2960, 2960-C and 2960-S Series (except specific number of ports). As far as I can see the Cisco SGE2000 has 4x SFP and is stackable unlike the SG300 with 2x miniGBIC/SFP, but not much else. Cisco Catalyst 2960 series offers some additional features like USB storage, but I can't imagine I will need that.
Any suggestions?
Thank you
Dan -
Troubleshooting Fiber Connection on a Catalyst 2960
I am trying to test my fiber connectivity on a Catalyst 2960 before I deploy it. So what I thought I would do is connect it to another switch in my office with a open port for the fiber connection. The other switch is a Catalyst 3560G. Here are the port configurations:
interface GigabitEthernet0/2
switchport trunk allowed vlan 1,100
switchport mode trunk
macro description cisco-switch
interface GigabitEthernet0/25
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 1,100
switchport mode trunk
The first one is the catalyst 2960 and the 3560G is the second.
When you show the interface for each of these it shows that it recognizes the media but the line protocal and the GigbitEthernet Port is down.
Any Ideas?Sorry... a fiber optic cable with a connector on each end.
To aid in troubleshooting, many times we loopback the signal back to the originating device. An optical loopback is just connecting the transmit (Tx) to the receive (Rx).
The multimode SFP/GBIC transceiver you are using will allow you to directly connect the Transmit and Receive ports without damage to the unit. This should provide you with a green link LED.
If so, then you can reconnect your fibers and loopback (connect the two fibers together) at the far end of the fiber link (use an optical adapter) and see if you get a green LED. -
Bandwidth monitoring on a Catalyst 2960
Hello all, I'm working with two Catalyst 2960 switches and I would like to know if there is a way to monitor bandwidth on individual ports. Ideally I would like to have one graph showing a bandwidth usage reading on each port. I tried using the Network Assistant to accomplish this, but I was only able to view one port at a time. I also tried using a traffic graphing program from Paessler, but a MIB file is needed to allow the program to connect to the switch. When I ran a search on the network management page the 2960 was not on the list for MIB supported products. Is this type of graph possible to do? Or is there a more effective way to accomplish what I would like to do. Any ideas or suggestions would be helpful.
Hi, we have just swapped all our avaya switches with catalyst 2960 (12, 24 and 48 ports) and 3750 (48 ports with 10gig module).
How do I find what port I should monitor for bandwith graphs?
Target[10.0.0.22_loc1]: 1:@10.0.0.22: -
Catalyst 2960 Problem with Cisco SPA512
Hi there,
I hope someone can help me.
I don't have much experience with switches, I'm doing the desktop support in our company.
We have Catalyst 4510 R+E to 2 Catalyst 2960 switches and seperate VLAN's for IP Phones and for Internet in one part of our office.
Now I'm running into trouble with some IP Phones that are connected to the 2960 switches. It appears only to happen with Cisco's SPA-512. I've tried FW 7.5.2, 7.5.5 and 7.5.5b. These phones sporadically drop the call / connection, with the red MIC button blinking. Based on my research this means that it looses Internet connection. I have 1 SPA512 with FW 7.5.1 that does not show these symptoms.
I have other phones SPA942 and Polycom IP335 in the same area behind the same switches and no issues.
We've tried to disable auto negotiate and set a fixed transmition rate or either 1Gbps and 100Mbps, both without success.
I also have SPA512 in other areas of the office just connected to our Catalyst 4510 R+E and they work just fine. That's why I don't believe it has anything to do with the 4510, but I can be wrong.
That's all I have for you guys. Hope someone can help me to fix / troubleshoot this..
FrankSSwitch3#test cable-diagnostics tdr int g1/0/16
TDR test started on interface Gi1/0/16
A TDR test can take a few seconds to run on an interface
Use 'show cable-diagnostics tdr' to read the TDR results.
SSwitch3#show cable-diagnostics tdr int g1/0/16
TDR test last run on: June 27 13:39:21
Interface Speed Local pair Pair length Remote pair Pair status
Gi1/0/16 1000M Pair A 52 +/- 10 meters Pair A Normal
Pair B 52 +/- 10 meters Pair B Normal
Pair C 52 +/- 10 meters Pair C Normal
Pair D 52 +/- 10 meters Pair D Normal
SSwitch3# -
Hello,
I would like to know if there is a way to validate that a SFP type 1000baseLX is working properly on catalyst 2960.
I am looking for the loop feature that is available on routers.... but not on switches.
The topology is 2 catalyst 2960 switches with both SFP type 1000baseLX connected together with a fiber. This was working find but actually, the two interfaces are down/down.
The idea is to be sure that the problem is on the fiber and not on one of the SFP....
Thank You for your help.UniDirectional Link Detection (UDLD) addresses your concern regarding the fiber. See http://www.cisco.com/en/US/docs/switches/lan/catalyst2960/software/release/12.2_46_se/configuration/guide/swudld.html for more information.
For the SFPs themselves, you might want to review http://www.cisco.com/en/US/products/hw/modules/ps4999/products_tech_note09186a00807a30d6.shtml for more information.
Hope this helps. -
Problem with Cisco Catalyst 2960
I've got a problem with the Catalyst 2960 / 24TCL switch. The Flash-directory was empty. After I copy with xmodem the firmware bin-file into the flash-directory and installed it .. I miss the HTML-Directory. Can somebody tell me how I can get it back?
SSwitch3#test cable-diagnostics tdr int g1/0/16
TDR test started on interface Gi1/0/16
A TDR test can take a few seconds to run on an interface
Use 'show cable-diagnostics tdr' to read the TDR results.
SSwitch3#show cable-diagnostics tdr int g1/0/16
TDR test last run on: June 27 13:39:21
Interface Speed Local pair Pair length Remote pair Pair status
Gi1/0/16 1000M Pair A 52 +/- 10 meters Pair A Normal
Pair B 52 +/- 10 meters Pair B Normal
Pair C 52 +/- 10 meters Pair C Normal
Pair D 52 +/- 10 meters Pair D Normal
SSwitch3# -
Cisco Network Assistant MAC search in Catalyst 2960
Hi,
Since I updated a Catalyst 2960 switch to IOS version 12.2(55)SE1 I can't do searchs by MAC address, when I do "Monitor->Search" the following error appears:
"The software version of the selected switch does not support some of the CLI commands in read-only mode for this window. You must have read-write access to this switch to display complete information in this window"
If packets are captured you can see that the issued command by the CNA host is "GET /exec/show/mac-address-table/", the answer from the switch is:
"show mac-address-table
^
% Invalid input detected at '^' marker.
If I do "Configure->Switching->MAC Address" instead I get the mac address-table correctly. In this case the issued command is "GET /exec/show/mac/address-table/dynamic" and no error is displayed, the answer from the switch is the list of mac-address table.I have some site admins that use CNA. I just upgraded their LAN to 3560v2 switches running 12.2(58)SE2 and had them upgrade their CNA software to CNA 5.7(6). They reported the same error.
I think you clearly indentified the problem. At one time the IOS command parser accepted both "show mac-address" and "show mac address". At some point IOS stopped accepting the older "show mac-address" format, and CNA is still issuing this command regardless of the IOS version it is trying to manage. -
Installed wrong image on Cisco Catalyst 2960
some time ago I did an IOS upgrade on the Catalyst 2960, however I used the wrong image and caused the switch CAN NOT load properly. My switch is c2960 but I used c2960s, what a big mistake.
When the switch boots, and it hangs on the execution of the image, because c2960s image will not work on c2960.
Anyone got some idea how I can fix this? I tried to restart the switch and pressed "Break" on the terminal, and it didn't stopped.
Using driver version 1 for media type 1
Base ethernet MAC Address: fc:fb:fb:f4:5b:00
Xmodem file system is available.
The password-recovery mechanism is enabled.
Initializing Flash...
mifs[2]: 0 files, 1 directories
mifs[2]: Total bytes : 3870720
mifs[2]: Bytes used : 1024
mifs[2]: Bytes available : 3869696
mifs[2]: mifs fsck took 0 seconds.
mifs[3]: 529 files, 19 directories
mifs[3]: Total bytes : 27998208
mifs[3]: Bytes used : 24108032
mifs[3]: Bytes available : 3890176
mifs[3]: mifs fsck took 11 seconds.
...done Initializing Flash.
done.
Loading "flash:/c2960s-universalk9-mz.122-58.SE1.bin"...@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@
File "flash:/c2960s-universalk9-mz.122-58.SE1.bin" uncompressed and installed, entry point: 0x3000
executing...
Thanks,
DavidHi David,
You have interuppt and get to the rommon mode and give boot: <old IOS image> if you have....
if that has been deleted.... then you have go with the recovery procedures like x modem or something
Regards
Karthik
Maybe you are looking for
-
Joining array variable to create a path
Hi, I would like merging 3 variables and using it to copy a file. What am I missing? set-variable -name ModuleVariables -visibility public -Scope Script -Value @("\Trousse\Modules","Variables.psm1") set-variable -name $PCompletTrousse -visibility pub
-
Ml_linkage entries (two modules in one)
I have two modules that I need to incorporate into one since they have shared state. I have successfully done this by adding a second entry to the ml_linkage member of the modlinkage structure. When I run modinfo, there are two entries under the same
-
Experimenting with looping through array
I've got this piece of code to check if some input of monosyllabic or not. Hope I can explain my problem with it. What it now does, is keep track of every first and last position of a vowel in the input. For a word like "bed", it works fine. The firs
-
Mail does not save changes to Preferences Accounts upon quitting
When I upgraded to Mavericks, I encountered two problems with Mail. They may actually be one problem, but I can't tell. The first, broader, and more concerning problem is that when I make a change to any account in Preferences > Accounts and then I q
-
About two tax code in one document
I just want to know, can i put to different different tax codes are except by system & is it possible for PLD also. Please anybody reply as soon as possible.