Catalyst 4500, scp, rcp
Does anybody know is it possible to set up a remote access to the Catalyst 4500 series switch thru the rcp or scp protocol? I want to start commands on the remote unix server. Like unix# scp -i identity -B acl.file user@catalyst:system:running-config or unix# rcp acl.file user@catalyst:system:running-config, where acl.file is the file with access-list. It's important to start commands on the remote server, not on the switch. Thanks for any advice.
Hello,
I just tried this on a Cat 4500 using tftp, and successfully changed its hostname, and added a new ACL.
The same should be true for rcp and scp.
Just remember to put "end" as the last line of the file, otherwise you will get a %PARSER-4-BADCFG: Unexpected end of configuration file message (but it still works).
This was tried on Version 12.2(25)EWA4.
Hope this helped,
Michael.
Similar Messages
-
Catalyst 4500 Ethernet and fibre channel passthru
dear sir,
anyone have any idea / documentation showing that the belows device 1.) & 2.) can support Ethernet and fibre channel passthru ? thanks.
1.) WS-X4424-GB-RJ4 (Catalyst 4500 24-port 10/100/1000 Module (RJ45)
2.) WS-X4306-GB (Catalyst 4500 Gigabit Ethernet Module, 6-Ports (GBIC)You're welcome. Check below for the module info. And there is description about support of fibre channel passthru.
http://www.cisco.com/en/US/products/hw/switches/ps4324/products_data_sheet0900aecd802109ea.html
You can also seach Cisco web for more info.
Hope this helps. -
Trunking on Nexus 5000 to Catalyst 4500
I have 2 devices on the each end of a Point to Point. One side has a Nexus 5000 the other end a Catalyst 4500. We want a trunk port on both sides to allow a single VLAN for the moment. I have not worked with Nexus before. Could someone look at the configurations of the Ports and let me know if it looks ok?
nexus 5000
interface Ethernet1/17
description
switchport mode trunk
switchport trunk allowed vlan 141
spanning-tree guard root
spanning-tree bpdufilter enable
speed 1000
Catalyst 4500
interface GigabitEthernet3/39
description
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 141
switchport mode trunk
speed 1000
spanning-tree bpdufilter enable
spanning-tree guard rootThanks guys, we found the issue. The Catalyst is on my side and the Nexus is on the side of the hosting center. The hosting center moved his connection to a different Nexus 5000 and the connection came right up. We dropped the spanning-tree guard root.
It was working on the previous nexus when we set the native vlan for 141. So we thought it was the point to point dropping the tags.
The hosting center engineer this it might have to do with the VPC Peer-Link loop prevention on the previous Nexus.
Anyway it is working the way we need it to. -
WS-X4306-GB - Catalyst 4500 6-port GBIC Module & FC Tape Libraries
WS-X4306-GB - Catalyst 4500 6-port GBIC Module & FC Tape Libraries
I have several Tape Autoloader Libraries from Dell which have Fibre Channel interfaces. I have loop switches that these connect to today. I also have a Catalyst 4506 with a WS-X4306-GB - 6-port GBIC Module. I would like to use the X4306 as a loop switch. Some of the libraries can also connect via point-to-point FC.
Can this be done? If yes, how do I start in making this happen?
Thank You.Sorry but the Catalyst 4500 does not support Fibre Channel connections on the WS-X4306-GB (or on any card). It's strictly an Ethernet switch. Reference
To mix and match Ethernet and FC interfaces, you'd have to be on a new platform like the Nexus 5k series - specifically the UP (Unified Port) variants. -
QoS trust dscp or cos on catalyst 4500
We have a 4510R with Cisco IOS Software, IOS-XE Software, Catalyst 4500 L3 Switch Software cat4500e-UNIVERSALK9-M), Version 03.05.02.E RELEASE SOFTWARE (fc1).
I want use qos trust dscp or qos trust cos on the interface conected to other cisco switch or wlan controller.
The current IOS version, do not support qos trust dscp:
SW(config)#interface gi10/16
SW(config-if)#qos tr
SW(config-if)#qos trust ?
device trusted device class
extend Extend trust through a connected device
SW(config-if)#qos trust device ?
cisco-phone Cisco IP Phone
cts Cisco-telepresence
ip-camera Cisco video surveillance camera
media-player Cisco Digital Media Player
SW(config-if)#qos trust device
What is the software that I need for this?. I tried with command lookup tool but the cat4500 do not appears.That is even new for me.
I did a search and found that, now a days you no longer have to provide the Trust DSCP command, it is by default trusted.
Went through this White Paper and excerpts are below:
http://www.cisco.com/c/en/us/products/collateral/switches/catalyst-4500-series-switches/white_paper_c11-539588.html
The answer to your question comes from the following excerpt :-
"Previously supervisor engines relied on “port trust” to classify traffic; however, this does not fall into the MQC CLI construct. MQC provides a more flexible capability, i.e. all traffic is trusted by default, an administrator can change this trust state using a policy map. Another difference is the “internal DSCP” value used within the switch to place packets in the proper queue.
Cisco Catalyst 4500E Supervisor Engines do not use “internal DSCP”; rather, it relies on explicit matching of QoS values using class maps so that packets can be placed in the correct queue.
Also, note that there is no specific priority queue: it is not queue 3 or queue 1. The priority queue is simply configured within a class; therefore, it is not tied to a specific queue. One final difference is that of classification. Cisco Catalyst 4500E Supervisor Engines provide sequential classification rather than parallel. This allows the network administrator to classify traffic at egress based on the ingress markings. These markings can be done unconditionally, using a policer or using a table map. Based on these changes, QoS CLI will now be more contiguous on the Supervisor Engines as it will now have standard Cisco MQC CLI, making configuration management much simpler"
HTH,
Please rate all helpful posts.
Regards -
Catalyst 4500-X, VSS, and SVI
Hello, everybody!
I have a proyect to implement the feature VSS, with two catalyst 4500-X, it will be the layer Core/Distribution.
So, I want integrate in the catalyst 4500X, Inter vlan routing (SVI) and vtp domain, in the layer access, we´ll have SW 3750-X with PoE.
Is possible configure SVI in my catalyst 4500-X. to separate traffic across VLANs. and the routing will be in the 4500X too. ???
My customer does not have sufficient space to mount the serie 4500E in the Rack, so he prefer the 4500-X.
Help me!
Thanks!
RegardsHi,
Is possible configure SVI in my catalyst 4500-X. to separate traffic across VLANs. and the routing will be in the 4500X too. ???
Yes, there is no different between a VSS pair and non-VSS when it comes to SVI and inter-vlan routing. It works the same way as if the 4500-X ware separate.
HTH -
Hi,
I have an issue with a Catalyst-4500 (4507R-E, ipbase, 12.2.46SG), that is running very hi CPU since some days:
By investigating, I observed a couple of processes that are realy CPU-consuming:
I don't know where to look ...
Some help and/or some suggestion ?
Best regars,
ClaudioTwo good resources for troubleshooting high CPU on the 4K
High CPU Utilization on Cisco IOS Software-Based Catalyst 4500 Switches
http://www.cisco.com/c/en/us/support/docs/switches/catalyst-4000-series-switches/65591-cat4500-high-cpu.html
Troubleshooting High CPU on the Catalyst 4500-E Series Switch
http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4500/troubleshooting/cpu_util.html
HTH
Luke -
Catalyst 4500, supervisor II+, EIGRP
Hi,
We're bought a catalyst 4500 sup II+ with image cat4000-i9s-mz.122-25.EWA4.bin
In feature navigator isn't anything about EIGRP in this image, but in CLI I may configure EIGRP.
How is that possible?
thxHi,
You can only configure the EIGRP stub on the Sup 2+. EIGRP fully is not supported on sup2+.
http://www.cisco.com/univercd/cc/td/doc/product/lan/cat4000/12_2_31s/conf/l3_int.htm#wp1042868
http://www.cisco.com/en/US/products/hw/switches/ps4324/products_data_sheet09186a0080197424.html
HTH, Please rate if it does.
-amit singh -
Hi All
I got 2 cisco catalyst 4500 l3 switches (Cisco IOS Software, IOS-XE Software, Version 03.02.00.XO RELEASE SOFTWARE (fc1))
I enabled Autoqos on one sw successfully without any issue
but facing issue on the second, below is the screenshot for your reference kindly suggest
Thanks!Yes it is.
See this link for details -
http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4500/12-2/54sg/configuration/guide/config/RPR.html#wp1130150
Jon -
SFP-10G-ZR support on Catalyst 4500 SUP6E
Hello,
is the SFP-10G-ZR supported on the SUP6-E with the OneX converter?
BR
O.GEnd-of-Sale and End-of-Life Announcement for the Cisco Catalyst 4500 Supervisor Engine 6-E
The chances of your SE submitting the PER is now ZERO. You'll be forced to upgrade to Sup7E. -
Is it possible to configure a catalyst 4500 for example, to be a AAA Server and hold a local username and password database for other switches/routers to authenticate against?
Thanks
WayneWayne
While it is possible to configure a catalyst switch as aaa client, and it is possible to configure a catalyst switch to do local authentication using a locally configured username/password database, I believe that it is not possible to configure a catalyst switch to provide authentication to other switches based on its local username/password database. I do not believe that the catalyst swithes include the server code for aaa.
HTH
Rick -
Subinterfaces - hardware limitation on catalyst 4500-X
Hi there,
We are currently building a VSS and our design has L3 subinterfaces however we have hit a major wall while trying to do the following
Create physical subinterface on VSS switch – Fail
Create port-channel subinterface on VSS switch – Fail
Create physical subinterface on standalone switch – Fail
Create port-channel subinterface on standalone switch – Fail
Below is the output showing that the option of a subinterfaces seems to be available, but it still doesn’t apply
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#int po1
Switch(config-if)#no swi
Switch(config-if)#no switchport
Switch(config-if)#int po1.1
^
% Invalid input detected at '^' marker.
Switch(config)#int po
Switch(config)#int port-channel 1.?
<0-4294967295> Port-channel interface number
Switch(config)#int port-channel 1.1
^
% Invalid input detected at '^' marker.
Switch(config)#int tenGigabitEthernet 1/1
Switch(config-if)#no swi
Switch(config-if)#no switchport
Switch(config-if)#exit
Switch(config)#int tenGigabitEthernet 1/1.?
<0-4294967295> TenGigabitEthernet interface number
Switch(config)#int tenGigabitEthernet 1/1.1
^
% Invalid input detected at '^' marker.
Switch(config)#
Here’s the show ver and show module output
Switch#show ver
Cisco IOS Software, IOS-XE Software, Catalyst 4500 L3 Switch Software (cat4500e-UNIVERSALK9-M), Version 03.07.00.E RELEASE SOFTWARE (fc4)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2014 by Cisco Systems, Inc.
Compiled Sun 07-Dec-14 22:13 by prod_rel_team
Cisco IOS-XE software, Copyright (c) 2005-2014 by cisco Systems, Inc.
All rights reserved. Certain components of Cisco IOS-XE software are
licensed under the GNU General Public License ("GPL") Version 2.0. The
software code licensed under GPL Version 2.0 is free software that comes
with ABSOLUTELY NO WARRANTY. You can redistribute and/or modify such
GPL code under the terms of GPL Version 2.0.
(http://www.gnu.org/licenses/gpl-2.0.html) For more details, see the
documentation or "License Notice" file accompanying the IOS-XE software,
or the applicable URL provided on the flyer accompanying the IOS-XE
software.
ROM: 15.0(1r)SG11
Switch uptime is 5 minutes
System returned to ROM by power-on
Running default software
Jawa Revision 2, Winter Revision 0x0.0x41
Last reload reason: power-on
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
[email protected].
*Apr 29 18:56:44.596: %SYS-5-CONFIG_I: Configured from console by console
License Information for 'WS-C4500X-32'
License Level: entservices Type: Permanent
Next reboot license Level: entservices
cisco WS-C4500X-32 (MPC8572) processor (revision 9) with 4194304K bytes of physical memory.
Processor board ID JAE191304FG
MPC8572 CPU at 1.5GHz, Cisco Catalyst 4500X
Last reset from PowerUp
1 Virtual Ethernet interface
32 Ten Gigabit Ethernet interfaces
511K bytes of non-volatile configuration memory.
Configuration register is 0x2101
Switch#
Switch#show module
Chassis Type : WS-C4500X-32
Power consumed by backplane : 0 Watts
Mod Ports Card Type Model Serial No.
---+-----+--------------------------------------+------------------+-----------
1 32 4500X-32 10GE (SFP+) WS-C4500X-32 JAE191304FG
M MAC addresses Hw Fw Sw Status
--+--------------------------------+---+------------+----------------+---------
1 b0aa.7777.5840 to b0aa.7777.585f 2.0 15.0(1r)SG11 03.07.00.E Ok
System Failures:
Power Supply: bad/off (see 'show power')
Switch#
All we can find is a little note on the release notes:
A Catalyst 4006 switch with Supervisor Engine III does not support subinterfaces or the encapsulation keyword on
Layer 3 Fast Ethernet, Gigabit Ethernet, 10-Gigabit Ethernet interfaces.
Source: http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4500/XE3-7-0E/15-23E/configuration/guide/xe-370-configuration/l3_int.html
I am assuming this restriction applies to this platform but other than that there is nothing specifying we can't do this. Anyone out there has hit the same issue? or can anyone confirm this is an actual platform restriction
Thank youHi,
The 4500 and 4500x series switches do not support sub-interfaces. Only 6500 series support sub-interfaces.
HTH -
IDS/IPS functionality in Catalyst 4500 ?
Hi,
is there an IDS/IPS functionality in Catalyst 4500 (Supervisor 6-e), or do we need to propose external IDS/IPS device?I think cat 4500 sup 6-e does not have IDS/IPS functionality. You have to externally install it.
http://www.cisco.com/en/US/prod/collateral/modules/ps2797/ps9294/product_data_sheet0900aecd806df543_ps4324_Products_Data_Sheet.html -
We have a 1000v switch uplinked to nexus 5K and Catalyst 4500 switches. I can see all the VEMs(ESX servers) connected to the nexus 5K uplink switch and everything seems working fine. However, I am not able to see the VEMs uplinked to Cisco Catalyst 4500 switch. The "show Module" command shows all VEMs connected to the nexus 5K uplink switches but not the Catalyst 4500 switches.The log file on the 1000V shows the following:
7 09:36:21 NX-1K-100 %VMS-5-DVS_HOSTMEMBER_INFO: A host with name=[IP ADD. OF ESX SERVER] and uuid=[34393232-3035-3255-5839-3430303
03537] is added to the dvs. The host is not found as a module in the VSM configuration.
If anyone have run into similar situation, plpease let me know how you handled it.
ThanksHi bharga,
I did all the checking....
1) all important VLANS including the control vlan are not blocked (No STP issue)
2) The Nexus 5K and the 4500 switch are in layer layer 2 ( They are not directly connected but are in layer two domain or no hop between them)
3) the ESX Server hosting the VSM is connected to the Nexus 5K
Here is some of the show commands that i run on the 4500 switch that is connects the ESX server to the rest ofd the network:-
Catalyst-4500#sh spanning-tree interface gigabitEthernet 1/38
Vlan Role Sts Cost Prio.Nbr Type
VLAN0073 Desg FWD 4 128.38 P2p Edge
VLAN0074 Desg FWD 4 128.38 P2p Edge
VLAN0151 Desg FWD 4 128.38 P2p Edge
VLAN0152 Desg FWD 4 128.38 P2p Edge
VLAN0153 Desg FWD 4 128.38 P2p Edge
VLAN0165 Desg FWD 4 128.38 P2p Edge
Catalyst-4500#sh mac address-table interface gigabitEthernet 1/38
Multicast Entries
vlan mac address type ports
-------+---------------+-------+--------------------------------------------
73 ffff.ffff.ffff system Gi1/32,Gi1/38,Gi1/42,Gi1/45
74 ffff.ffff.ffff system Gi1/38,Gi1/41,Gi1/45
151 ffff.ffff.ffff system Gi1/3,Gi1/5,Gi1/6,Gi1/7,Gi1/9,Gi1/10,Gi1/11
Gi1/12,Gi1/14,Gi1/16,Gi1/17,Gi1/18,Gi1/19
Gi1/21,Gi1/22,Gi1/23,Gi1/25,Gi1/26,Gi1/27
I still don't see the VEM connected to port 1/38 of this switch on my nexus 1000v switch. The configuration file show exactly how many VEMs I have as shown below:
Nexus-1000v# sh running-config
host vmware id 34373030-3635-3255-5830-303630344
vem 4
host vmware id 34373030-3635-3255-5830-313130313
vem 5
host vmware id 34373030-3635-3255-5830-303630344
vem 6
host vmware id 34393232-3035-3255-5839-3134303537
vem 7
host vmware id 34373030-3635-3255-5830-313130313
vem 8
host vmware id 33393138-3335-5553-4539-31314e3438
vem 9
host vmware id 34393232-3035-3255-5839-3339303646
vem 10
host vmware id 34393232-3035-3255-5839-3430303035
vem 11
host vmware id 34393232-3035-3255-5839-3339303646
But the show module command on the nexus 1000v shows only those VEMs coonected to the Nexus 5K switches and not those connected to the Catalyst 4500 switches.
the uplink por-profile confguration on the Nexus 1000 V :
vmware port-group
switchport mode trunk
switchport trunk native vlan 74
switchport trunk allowed vlan 73-74,151-153,165,180,811,813,815,817-822,824,826-831
channel-group auto mode on sub-group cdp
no shutdown
system vlan 74,180,811,819-821
state enabled
the corresponding interface on the 4500 switch :
interface GigabitEthernet1/38
switchport trunk encapsulation dot1q
switchport trunk native vlan 74
switchport trunk allowed vlan 73,74,151-153,165,180,811,813,815,817-822,824
switchport trunk allowed vlan add 826-831
switchport mode trunk
mtu 9000
spanning-tree portfast trunk
I really appreciate in finiding out why I can't see the VEM (ESX Servers) connected to the 4500 switches.
Thanks -
Upgrade Catalyst 4500 Supervisor Engine 8-E(IOS XE Software)
Folks,
We are looking to upgrade the Catalyst 4500 Supervisor Engine 8-E(IOS XE Software). As of now we are running on 3.3.1XO and as per the Cisco notes version 3.3.2XO which is suggested version.
I would like to find some comparison documents on both these version and establish if there is a need to do the upgrade. What are the fixes that have been done in this version.
Thanks,!!Hi Nikhil,
Please find release notes of version 3.3.2XO below which can provide you the details to upgrade.
Mainly you need to refer the features it supports and resolved cavets (which means the bugs resolved fro the earlier version on to this.).
http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4500/release/note/OL_29983-01.html
HTH
Regards
Inayath
*Plz rate if this info is helpfull.
Maybe you are looking for
-
Can use adobe livecycle reader extensions es to compile adobe livecycle designer ES3 file?
Hi , I am using livecycle designer ES and livecycle reader extensions es to create some PDF files. I want to use the new feature action builder, so I downloaded the designer ES3. After creating some new files, I tried to use livecycle reader extensio
-
I installed my upgrade for Photoshop CS5 today and then downloaded the Contact Sheet II plug-in.... the plug-in is in my CS5 plug-in folder when I try to launch it in CS5... via the AUTOMATE pull down, it DOES NOT SHOW... it DOES show up in Brdige CS
-
I have Intel Core Duo, will Lion work on it if I decide to upgrade?
My MacBook Pro is run on Intel Core Duo. Albeit, I have Snow Leopard 10.6.8, can I upgrade to Lion?
-
Dreamweaver CS3 has just started to crash when I open any file. I get the following error. Has anyone had the same problem or knows how to fix this. AppName: dreamweaver.exe AppVer: 9.0.0.3481 ModName: dreamweaver.exe ModVer: 9.0.0.3481 Offset: 002da
-
Why don't I have Bookmarks Manager? I have a MacBook Pro
I have Firefox 6.0.2 I have Mac OS X V 10.5.8