Catch frame's closing event

Hi,
I was wondering how to accomplish this...
How can I catch the closing event, that a user creates by clicking on the X on the top upper right of a jframe?
I have a cancel button that calls an onCancel method, and I need to also call that onCancel method for that action.
public void onCancel() {
   // Cancel the operation
}Any suggestions?
V

I'll answer;
myframe.addWindowListener(new WindowAdapter()
                                public void windowClosing(WindowEvent we)
                                                 {onCancel();}
                               });Another way would be to:
class MyWindowListener extends WindowAdapter()
private MyClassWithOnCancelMethod mcwocm;
public MyWindowListener(MyClassWithOnCancelMethod moc)
   mcwocm = moc;
public void windowClosing(WindowEvent we)
   mcwocm.onCancel();
}And then, in your previous class:
MyWindowListener mwl = new MyWindowListener(this);
myframe.addWindowListener(mwl);Kinda your choice.
~David

Similar Messages

  • Identify Frame generating 'closed'-event

    I have a jSplittedPane with a jTree on the left, a JDesktopPane on the right.
    When i select an item in the tree on the left, an jInternalFrame (application) is added (and displayed) on the jDesktopPane.
    I can switch to any item (app) at any moment by selecting other items.
    I have added a 'closed'-propertylistener to each frame added on the jDesktopPane.
    myFrame.addPropertyChangeListener("closed", new closeInternalFrame()); When i close a frame (app) on the jDesktopPane, the listener is triggered and i can do some actions
         class closeInternalFrame implements PropertyChangeListener {
            public void propertyChange(PropertyChangeEvent e) {
                  setCurrentEvent(e);
                  deActivateApplication();
            }To identify the jInternalFrame which triggers the closed-event, i do a test on the 'source' of the event
            if ((getCurrentEvent().getSource() instanceof myApp_x.myAppConstructor)){
                this.myApp_x = null;
                removeFromActiveApplicationList("Application_x");
            }This works nicely but... now comes the tricky part:
    It does not work when i open 2 jInternalFrames using the same class/constructor...
    Question:
    Is there any other way to 'identify' the jInternalFrame which triggers the 'closed'-event?
    I can 'name' my jInternalFrame but i cannot test it when the event is triggered...
            myFrame.setName("Frame1");

    Why aren't you using <tt>InternalFrameListener#windowClosed / windowClosing</tt>?
    db

  • Catching window closing events from JFrame

    I'm having problems catching windowClosing() events from a JFrame (just doesn't get to my event listener it would seem!).
    I register and setup a window listener in the constructor of my JFrame class. Prior to this I set the default close operation as DO_NOTHING_ON_CLOSE (as you're suppose to if tyou want to handle window closing events).
    When user clicks on x (window terminate) button (in WIN systems), nothing is dispatched to my event listener. Any ideas?
    Extract from constructor:
    setDefaultCloseOperation(DO_NOTHING_ON_CLOSE);
    addWindowListener(new MainWindowListener(this));
    MainWindowListener looks as follows (EDImemConvert extends JFrame):
    class MainWindowListener extends WindowAdapter
    private EDImemConvert f;
    public MainWindowListener(EDImemConvert f)
    this.f = f;
    public void windowClosing(WindowEvent e)
    System.out.println("gets here...");
    f.ReturnResources();
    f.dispose();
    System.exit(0);
    }

    This works for meimport java.awt.*;
    import java.awt.event.*;
    import javax.swing.*;
    public class Test extends JFrame {
      public Test() {
        addWindowListener(new WindowAdapter() {
          public void windowClosing(WindowEvent we) { System.exit(0); }
        setSize(300,300);
        setVisible(true);
      public static void main(String args[]) { new Test(); }
    }Normally, I just use this line
    setDefaultCloseOperation(JFrame.EXIT_ON_CLOSE);
    instead of adding a listener. It will clean up everything nicely.

  • How to stop frame from closing?

    Hi,
    ramka.addWindowListener(new WindowAdapter()
                  public void windowClosing(WindowEvent e)
                      Object [] qqq = {"yes", "no"};
                      int answer = JOptionPane.showOptionDialog(
                                null,
                                 "want to close window?",
                                 JOptionPane.YES_NO_OPTION,
                                  JOptionPane.QUESTION_MESSAGE,
                                  null,
                                 qqq,
                                 qqq[1]);
                      if (answer == JOptionPane.YES_OPTION)
                           // WHAT TO DO TO STOP WINDOW FROM CLOSING?
                  });as you can see above i want to stop frame from closing.
    what should i do in the commented line?
    or maybe somewhere else?
    please help,
    thanks

    Hello friend,
    I've found a solution for your query. I think, you'll get a solution from my codings. I've given you below my codings,plz go through it.Verify it. Reply me about my codings.
    import java.awt.*;
    import java.awt.event.*;
    import javax.swing.*;
    import javax.swing.JOptionPane;
    public class MyFrame extends JFrame{
         JButton jb=new JButton("My Details");
         public MyFrame(){
         JPanel jp=new JPanel();
         jp.add(jb,new FlowLayout(FlowLayout.CENTER));
         add(jp);
         jb.addActionListener(new ActionListener(){
         public void actionPerformed(ActionEvent ae){
                   if(ae.getSource()==jb){
                        String str[]={
                             "Name : Karthikeyan.K",
                             "Email-ID : [email protected]"
                        JOptionPane.showMessageDialog(null, str);
    WindowCloser wc=new WindowCloser();
    addWindowListener(wc);
         class WindowCloser extends WindowAdapter{
              public void windowClosing(WindowEvent we){
                   int res=JOptionPane.showConfirmDialog(null,"Do you want to exit from it?","Confirmation!!!",JOptionPane.YES_NO_CANCEL_OPTION,JOptionPane.QUESTION_MESSAGE);
                   switch(res){
                        case JOptionPane.YES_OPTION:
                             dispose();
                             System.exit(0);
                             break;
                        case JOptionPane.NO_OPTION:
                             repaint();
                             doOpenFrame();
                             break;
                        case JOptionPane.CANCEL_OPTION:
                             repaint();
                             doOpenFrame();
                             break;
                        case JOptionPane.CLOSED_OPTION:
                             repaint();
                             doOpenFrame();
                             break;
         public static void doOpenFrame(){
              MyFrame mf=new MyFrame();
              mf.pack();
              mf.setSize(400,400);
              mf.setVisible(true);
         public static void main(String ar[]){
         doOpenFrame();
    }

  • Why can not catch the standard BACK event in ALV's USER_COMMAND event,

    Hi expert, why i can not catch the standard BACK event in ALV's USER_COMMAND event,
    Code:
    DATA G_CON_UC_FORM   TYPE SLIS_FORMNAME VALUE 'F_USER_COMMAND',
    CALL FUNCTION 'REUSE_ALV_GRID_DISPLAY'
        EXPORTING
          I_CALLBACK_PROGRAM      = SY-REPID
          I_CALLBACK_TOP_OF_PAGE  = G_CON_FORM
          I_CALLBACK_USER_COMMAND = G_CON_UC_FORM
          IT_FIELDCAT             = G_TAB_FIELDCAT
          IT_SORT                 = G_TAB_SORT_INF
          I_SAVE                  = G_CON_U
    *<<<Liang
        IT_EVENTS               = G_TAB_ALV_EVENTS
    *<<<Liang
        TABLES
          T_OUTTAB                = G_TAB_OUTPUT_DATA
        EXCEPTIONS
          PROGRAM_ERROR           = 1
          OTHERS                  = 2.
    *&      Form  F_USER_COMMAND
          ALV USER COMMAND processing
    FORM F_USER_COMMAND .
      IF SY-UCOMM = '&FO3'.
        LEAVE TO SCREEN 0.
      ENDIF.
    ENDFORM.                    " F_USER_COMMAND
    When I set breakpoint on this subrouting ,and try to click stardard  BACK or CANCEL button, the callback form do not run, but if double click one of line of alv report, the callback form works well,
    so why??

    hi
    good
    check this report and change your code accordingly.
    THESE LINES ARE FOR THE MAIN PROGRAM ***
    SAP V40B ***
    REPORT Z_PICK_LIST .
    TABLES: RESB.
    SELECTION-SCREEN BEGIN OF BLOCK BL1 WITH FRAME TITLE TEXT-BL1.
    SELECT-OPTIONS: S_WERKS FOR RESB-WERKS," Plant
                    S_AUFNR FOR RESB-AUFNR," Order number
                    S_BDTER FOR RESB-BDTER." Req. date
    SELECTION-SCREEN END OF BLOCK BL1.
    PARAMETERS: P_VARI LIKE DISVARIANT-VARIANT DEFAULT '/STANDARD'.
    DATA: BEGIN OF OUT OCCURS 10,
            AUFNR LIKE RESB-AUFNR,         " Order number
            MATNR LIKE RESB-MATNR,         " Material
            BDMNG LIKE RESB-BDMNG,         " Requirements in UM
            MEINS LIKE RESB-MEINS,         " Unit of Measure (UM)
            ERFMG LIKE RESB-ERFMG,         " Requirements in UE
            ERFME LIKE RESB-ERFME,         " Unit of Entry (UE)
            MAKTX LIKE MAKT-MAKTX,         " Mat. description
          END OF OUT.
    INCLUDE Z_ALV_VARIABLES.
    INITIALIZATION.
      REPNAME = SY-REPID.
      PERFORM INITIALIZE_FIELDCAT USING FIELDTAB[].
      PERFORM BUILD_EVENTTAB USING EVENTS[].
      PERFORM BUILD_COMMENT USING HEADING[].
      PERFORM INITIALIZE_VARIANT.
    AT SELECTION-SCREEN ON VALUE-REQUEST FOR P_VARI.
      PERFORM F4_FOR_VARIANT.
    AT SELECTION-SCREEN.
      PERFORM PAI_OF_SELECTION_SCREEN.
    START-OF-SELECTION.
      PERFORM GET_ORDERS.
      PERFORM GET_MATERIAL_DESCRIPTION.
    END-OF-SELECTION.
      PERFORM BUILD_LAYOUT USING LAYOUT.
      PERFORM BUILD_PRINT  USING PRINTS.
      PERFORM WRITE_USING_ALV.
          FORM INITIALIZE_FIELDCAT                               *
    -->  P_TAB                                                         *
    FORM INITIALIZE_FIELDCAT USING P_TAB TYPE SLIS_T_FIELDCAT_ALV.
      DATA: CAT TYPE SLIS_FIELDCAT_ALV.
      CLEAR CAT.
    ENDFORM.                               " INITIALIZE_FIELDCAT
    *&      Form  GET_ORDERS
          text
    FORM GET_ORDERS.
      SELECT AUFNR MATNR BDMNG MEINS ERFMG ERFME
             FROM RESB
             APPENDING TABLE OUT
             WHERE XLOEK EQ SPACE          " deletion indicator
             AND   XWAOK EQ 'X'            " goods movement indicator
             AND   WERKS IN S_WERKS        " plant
             AND   BDTER IN S_BDTER        " req. date
             AND   AUFNR IN S_AUFNR.       " pr. order
    ENDFORM.                               " GET_ORDERS
    *&      Form  GET_MATERIAL_DESCRIPTION
          text
    FORM GET_MATERIAL_DESCRIPTION.
      SORT OUT BY MATNR.
      LOOP AT OUT.
        SELECT SINGLE MAKTX
               INTO OUT-MAKTX
               FROM MAKT
               WHERE MATNR EQ OUT-MATNR
               AND   SPRAS EQ 'EN'.
        MODIFY OUT.
      ENDLOOP.
      SORT OUT BY AUFNR MATNR.
    ENDFORM.                               " GET_MATERIAL_DESCRIPTION
          FORM TOP_OF_PAGE                                              *
    FORM TOP_OF_PAGE.
      DATA: L_POS TYPE P.
    first line
      WRITE:/ TEXT-001.                    " Plant:
      IF S_WERKS-HIGH NE SPACE.
        WRITE: S_WERKS-LOW, TEXT-TO1, S_WERKS-HIGH.
      ELSEIF S_WERKS-LOW NE SPACE.
        LOOP AT S_WERKS.
          WRITE: S_WERKS-LOW.
        ENDLOOP.
      ELSEIF S_WERKS-LOW EQ SPACE.
        WRITE: TEXT-ALL.
      ENDIF.
      L_POS = ( SY-LINSZ DIV 2 ) - ( STRLEN( TEXT-TIT ) DIV 2 ).
      POSITION L_POS. WRITE: TEXT-TIT.
      L_POS = SY-LINSZ - 20.
      POSITION L_POS. WRITE: TEXT-011, SY-UNAME RIGHT-JUSTIFIED.  " User:
    second line
      WRITE:/ TEXT-002.                    " Order:
      IF S_AUFNR-HIGH NE SPACE.
        WRITE: S_AUFNR-LOW, TEXT-TO1, S_AUFNR-HIGH.
      ELSEIF S_AUFNR-LOW NE SPACE.
        LOOP AT S_AUFNR.
          WRITE: S_AUFNR-LOW.
        ENDLOOP.
      ELSEIF S_AUFNR-LOW EQ SPACE.
        WRITE: TEXT-ALL.
      ENDIF.
      L_POS = SY-LINSZ - 20.
      POSITION L_POS. WRITE: TEXT-012,SY-DATUM.      " Date:
    third line
      WRITE:/ TEXT-003.                    " Req. Date:
      IF S_BDTER-HIGH(1) NE '0'.
        WRITE: S_BDTER-LOW, TEXT-TO1, S_BDTER-HIGH.
      ELSEIF S_BDTER-LOW(1) NE '0'.
        LOOP AT S_BDTER.
          WRITE: S_BDTER-LOW.
        ENDLOOP.
      ELSEIF S_BDTER-LOW(1) EQ '0'.
        WRITE: TEXT-ALL.
      ENDIF.
      L_POS = SY-LINSZ - 20.
      POSITION L_POS. WRITE: TEXT-013, SY-PAGNO.   " Page:
    ENDFORM.                               " TOP_OF_PAGE
          FORM END_OF_LIST                                              *
    FORM END_OF_LIST.
      DATA: L_POS TYPE P.
      ULINE.
      WRITE:/ '|', TEXT-021.      " Delivered by:
      L_POS = SY-LINSZ DIV 2.
      POSITION L_POS. WRITE: '|', TEXT-031.            " Received by:
      L_POS = SY-LINSZ.
      POSITION L_POS. WRITE: '|'.
      WRITE:/ '|'.
      L_POS = SY-LINSZ DIV 2.
      POSITION L_POS. WRITE: '|'.
      L_POS = SY-LINSZ.
      POSITION L_POS. WRITE: '|'.
      ULINE.
      WRITE:/ '|', TEXT-012.      " Date:
      L_POS = SY-LINSZ DIV 2.
      POSITION L_POS. WRITE: '|', TEXT-012.            " Date:
      L_POS = SY-LINSZ.
      POSITION L_POS. WRITE: '|'.
      WRITE:/ '|'.
      L_POS = SY-LINSZ DIV 2.
      POSITION L_POS. WRITE: '|'.
      L_POS = SY-LINSZ.
      POSITION L_POS. WRITE: '|'.
      ULINE.
    ENDFORM.                               " END_OF_LIST
    *&      Form  WRITE_USING_ALV
          text
    FORM WRITE_USING_ALV.
      CALL FUNCTION 'REUSE_ALV_FIELDCATALOG_MERGE'
           EXPORTING
                I_PROGRAM_NAME     = REPNAME
                I_INTERNAL_TABNAME = 'OUT'
                I_INCLNAME         = REPNAME
           CHANGING
                CT_FIELDCAT        = FIELDTAB.
      IF SY-SUBRC <> 0.
        WRITE: 'SY-SUBRC: ', SY-SUBRC, 'REUSE_ALV_FIELDCATALOG_MERGE'.
      ENDIF.
      CALL FUNCTION 'REUSE_ALV_LIST_DISPLAY'
           EXPORTING
                I_CALLBACK_PROGRAM       = REPNAME
               i_callback_pf_status_set = 'PF_STATUS_SET'
               i_callback_user_command  = 'USER_COMMAND'
                I_STRUCTURE_NAME         = 'OUT'
                IS_LAYOUT                = LAYOUT
                IT_FIELDCAT              = FIELDTAB
                I_DEFAULT                = 'A'
                I_SAVE                   = G_SAVE
                IS_VARIANT               = G_VARIANT
                IT_EVENTS                = EVENTS[]
                IS_PRINT                 = PRINTS
           TABLES
                T_OUTTAB                 = OUT.
      IF SY-SUBRC <> 0.
        WRITE: 'SY-SUBRC: ', SY-SUBRC, 'REUSE_ALV_LIST_DISPLAY'.
      ENDIF.
    ENDFORM.                               " WRITE_USING_ALV
    THESE LINES ARE FOR THE INCLUDE ***
    ***INCLUDE Z_ALV_VARIABLES .
    TYPE-POOLS: SLIS.
    DATA: FIELDTAB TYPE SLIS_T_FIELDCAT_ALV,
          HEADING  TYPE SLIS_T_LISTHEADER,
          LAYOUT   TYPE SLIS_LAYOUT_ALV,
          EVENTS   TYPE SLIS_T_EVENT,
          REPNAME  LIKE SY-REPID,
          F2CODE   LIKE SY-UCOMM VALUE  '&ETA',
          PRINTS   TYPE SLIS_PRINT_ALV,
          TITLE(40) TYPE C,
          G_SAVE(1) TYPE C,
          G_EXIT(1) TYPE C,
          G_VARIANT LIKE DISVARIANT,
          GX_VARIANT LIKE DISVARIANT.
    CONSTANTS: FORMNAME_TOP_OF_PAGE TYPE SLIS_FORMNAME VALUE 'TOP_OF_PAGE',
               FORMNAME_END_OF_PAGE TYPE SLIS_FORMNAME VALUE 'END_OF_PAGE',
               FORMNAME_END_OF_LIST TYPE SLIS_FORMNAME VALUE 'END_OF_LIST',
               FORMNAME_BEFORE_LINE TYPE SLIS_FORMNAME VALUE 'BEFORE_LINE',
               FORMNAME_AFTER_LINE TYPE SLIS_FORMNAME VALUE 'AFTER_LINE'.
          FORM MAIN_STATEMENTS                                          *
    THIS IS THE CODE THAT MUST BE INSERTED IN THE MAIN PROGRAM
    FORM MAIN_STATEMENTS.
    Declare the parameter P_VARI wherever you want it. If you don't
    want it, hide it with NO-DISPLAY, but it must exist.
    parameters: p_vari like disvariant-variant. " ALV Variant
    You have to add the following line after the data and parameter
    declaration:
    include z_alv_variables.
    Then, after the data/parameter declaration, add these lines:
    *initialization.
    repname = sy-repid.
    perform initialize_fieldcat using fieldtab[].
    perform build_eventtab using events[].
    perform build_comment using heading[].
    perform initialize_variant.
    If you are using the variable P_VARI (ALV Variant), also add this:
    *at selection-screen on value-request for p_vari.
    perform f4_for_variant.
    *at selection-screen.
    perform pai_of_selection_screen.
    After the "END-OF-SELECTION" statement, add these lines:
    perform build_layout using layout.
    perform build_print  using prints.
    perform write_using_alv.
    You also have to create the following forms: (you can find samples
    in this program)
    INITIALIZE_FIELDCAT
    USER_COMMAND     (only if you are creating a STATUS)
    WRITE_USING_ALV
    ENDFORM.
    *&      Form  INITIALIZE_FIELDCAT_SAMPLE
          THIS IS A SAMPLE, DO NOT USE THIS FORM IN YOUR PROGRAM
         -->P_FIELDTAB[]  text                                           *
    FORM INITIALIZE_FIELDCAT_SAMPLE USING P_TAB TYPE SLIS_T_FIELDCAT_ALV.
      DATA: CAT TYPE SLIS_FIELDCAT_ALV.
      CLEAR CAT.                           " Always clear before use
      CAT-TABNAME = 'I'.                   " Your internal table
      CAT-REF_TABNAME = 'ZCUSTMAS'.  " The data dictionary reference table
      CAT-FIELDNAME = 'KUNNR'.       " Name of your field in the itable.
      CAT-COL_POS   = 1.                   " Output position
      APPEND CAT TO P_TAB.
      CAT-FIELDNAME = 'NAME1'.             " Next field
      CAT-COL_POS   = 2.
      APPEND CAT TO P_TAB.
      CAT-FIELDNAME = 'STRAS'.             " and the next
      CAT-COL_POS   = 3.
      APPEND CAT TO P_TAB.
      CAT-FIELDNAME = 'LOEVM'.
      CAT-SELTEXT_S = 'Del'.         " You can always override the descrip-
      CAT-SELTEXT_M = 'Delivery'.          " tion (short, medium, large)
      CAT-SELTEXT_L = 'Delivery Num'.
      CAT-COL_POS   = 4.
      APPEND CAT TO P_TAB.
      CAT-FIELDNAME = 'FKIMG'.
      CAT-DO_SUM    = 'X'.                 " You want totals calculated.
      CAT-NO_OUT    = 'X'.                 " and hidden.
      APPEND CAT TO P_TAB.
    ENDFORM.                               " INITIALIZE_FIELDCAT
    *&      Form  BUILD_EVENTTAB
          THIS IS THE SAME FOR ALL THE PROGRAMS
         -->P_EVENTS[]  text                                             *
    FORM BUILD_EVENTTAB USING P_EVENTS TYPE SLIS_T_EVENT.
      DATA: LS_EVENT TYPE SLIS_ALV_EVENT.
      CALL FUNCTION 'REUSE_ALV_EVENTS_GET'
           EXPORTING
                I_LIST_TYPE = 0
           IMPORTING
                ET_EVENTS   = P_EVENTS.
      READ TABLE P_EVENTS WITH KEY NAME = SLIS_EV_TOP_OF_PAGE
                               INTO LS_EVENT.
      IF SY-SUBRC = 0.
        MOVE FORMNAME_TOP_OF_PAGE TO LS_EVENT-FORM.
        APPEND LS_EVENT TO P_EVENTS.
      ENDIF.
      CLEAR LS_EVENT.
      READ TABLE P_EVENTS WITH KEY NAME = SLIS_EV_END_OF_LIST
                               INTO LS_EVENT.
      IF SY-SUBRC = 0.
        MOVE FORMNAME_END_OF_LIST TO LS_EVENT-FORM.
        APPEND LS_EVENT TO P_EVENTS.
      ENDIF.
      CLEAR LS_EVENT.
      READ TABLE P_EVENTS WITH KEY NAME = SLIS_EV_BEFORE_LINE_OUTPUT
                               INTO LS_EVENT.
      IF SY-SUBRC = 0.
        MOVE FORMNAME_BEFORE_LINE TO LS_EVENT-FORM.
        APPEND LS_EVENT TO P_EVENTS.
      ENDIF.
      CLEAR LS_EVENT.
      READ TABLE P_EVENTS WITH KEY NAME = SLIS_EV_AFTER_LINE_OUTPUT
                               INTO LS_EVENT.
      IF SY-SUBRC = 0.
        MOVE FORMNAME_AFTER_LINE TO LS_EVENT-FORM.
        APPEND LS_EVENT TO P_EVENTS.
      ENDIF.
      CLEAR LS_EVENT.
      READ TABLE P_EVENTS WITH KEY NAME = SLIS_EV_END_OF_PAGE
                               INTO LS_EVENT.
      IF SY-SUBRC = 0.
        MOVE FORMNAME_END_OF_PAGE TO LS_EVENT-FORM.
        APPEND LS_EVENT TO P_EVENTS.
      ENDIF.
    ENDFORM.                               " BUILD_EVENTTAB
    *&      Form  BUILD_COMMENT
    NOT REALLY NEEDED, BUT I'LL LEAVE IT THERE, JUST IN CASE...
         -->P_HEADING[]  text                                            *
    FORM BUILD_COMMENT USING P_HEADING TYPE SLIS_T_LISTHEADER.
      DATA: HLINE TYPE SLIS_LISTHEADER,
            TEXT(60) TYPE C,
            SEP(20) TYPE C.
      CLEAR: HLINE, TEXT.
      HLINE-TYP  = 'H'.
    write: text-101 to text+23.
      HLINE-INFO = TEXT.
      APPEND HLINE TO P_HEADING.
    ENDFORM.                               " BUILD_COMMENT
    *&      Form  INITIALIZE_VARIANT
    VERY IMPORTANT WHEN YOU USE VARIANTS!!!
    FORM INITIALIZE_VARIANT.
      G_SAVE = 'A'.
      CLEAR G_VARIANT.
      G_VARIANT-REPORT = REPNAME.
      GX_VARIANT = G_VARIANT.
      CALL FUNCTION 'REUSE_ALV_VARIANT_DEFAULT_GET'
           EXPORTING
                I_SAVE     = G_SAVE
           CHANGING
                CS_VARIANT = GX_VARIANT
           EXCEPTIONS
                NOT_FOUND  = 2.
      IF SY-SUBRC = 0.
        P_VARI = GX_VARIANT-VARIANT.
      ENDIF.
    ENDFORM.                               " INITIALIZE_VARIANT
    *&      Form  PAI_OF_SELECTION_SCREEN
    ALSO FOR VARIANTS
    FORM PAI_OF_SELECTION_SCREEN.
      IF NOT P_VARI IS INITIAL.
        MOVE G_VARIANT TO GX_VARIANT.
        MOVE P_VARI TO GX_VARIANT-VARIANT.
        CALL FUNCTION 'REUSE_ALV_VARIANT_EXISTENCE'
             EXPORTING
                  I_SAVE     = G_SAVE
             CHANGING
                  CS_VARIANT = GX_VARIANT
             EXCEPTIONS
                  WRONG_INPUT   = 1
                  NOT_FOUND     = 2
                  PROGRAM_ERROR = 3.
        IF SY-SUBRC EQ 0.
          G_VARIANT = GX_VARIANT.
        ELSE.
          PERFORM INITIALIZE_VARIANT.
        ENDIF.
      ELSE.
        PERFORM INITIALIZE_VARIANT.
      ENDIF.
    ENDFORM.                               " PAI_OF_SELECTION_SCREEN
    *&      Form  F4_FOR_VARIANT
          text
    FORM F4_FOR_VARIANT.
      CALL FUNCTION 'REUSE_ALV_VARIANT_F4'
           EXPORTING
                IS_VARIANT = G_VARIANT
                I_SAVE     = G_SAVE
           IMPORTING
                E_EXIT     = G_EXIT
                ES_VARIANT = GX_VARIANT
           EXCEPTIONS
                NOT_FOUND  = 2.
      IF SY-SUBRC = 2.
        MESSAGE ID SY-MSGID TYPE 'S'      NUMBER SY-MSGNO
                WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
      ELSE.
        IF G_EXIT = SPACE.
          P_VARI = GX_VARIANT-VARIANT.
        ENDIF.
      ENDIF.
    ENDFORM.                               " F4_FOR_VARIANT
    *&      Form  BUILD_LAYOUT
    STANDARD LAYOUT
         -->P_LAYOUT  text                                               *
    FORM BUILD_LAYOUT USING P_LAYOUT TYPE SLIS_LAYOUT_ALV.
      P_LAYOUT-F2CODE       = F2CODE.
      P_LAYOUT-ZEBRA        = 'X'.
    p_layout-detail_popup = 'X'.
      P_LAYOUT-TOTALS_TEXT  = SPACE.
      P_LAYOUT-SUBTOTALS_TEXT = SPACE.
    ENDFORM.                               " BUILD_LAYOUT
          FORM BUILD_PRINT                                              *
    STANDARD PRINT OPTIONS                                             *
    -->  P_PRINT                                                       *
    FORM BUILD_PRINT USING P_PRINT TYPE SLIS_PRINT_ALV.
      P_PRINT-NO_PRINT_LISTINFOS = 'X'.
      P_PRINT-NO_PRINT_SELINFOS  = ' '.
    ENDFORM.                               " BUILD_PRINT
          FORM PF_STATUS_SET                                            *
    NAME YOUR STATUS ALV. IF YOU NEED IT..                             *
    FORM PF_STATUS_SET USING EXTAB TYPE SLIS_T_EXTAB.
      SET PF-STATUS 'ALV' EXCLUDING EXTAB.
    ENDFORM.                               " PF_STATUS_SET
          FORM USER_COMMAND_SAMPLE                                      *
    -->  UCOMM                                                         *
    -->  SELFIELD                                                      *
    FORM USER_COMMAND_SAMPLE USING UCOMM    LIKE SY-UCOMM
                               SELFIELD TYPE SLIS_SELFIELD.
      CASE UCOMM.
        WHEN 'MSXL'.                       " Export to Excel
         perform set_excel_export.
          CLEAR UCOMM.
        WHEN 'MM03'.
         set parameter id 'MAT' field selfield-value.
         call transaction 'MM03' and skip first screen.
          CLEAR UCOMM.
        WHEN 'BGR1'.
         perform fill_available.
         perform graph_available.
          CLEAR UCOMM.
        WHEN 'DOCU'.
         call function 'Z_HELP' exporting repname = repname.
      ENDCASE.
    ENDFORM.                               " USER_COMMAND
    *&      Form  WRITE_USING_ALV_SAMPLE
    *THIS IS A SAMPLE AND MUST BE WRITTEN DIRECTLY IN THE MAIN PROGRAM
    FORM WRITE_USING_ALV_SAMPLE.
    YOU CAN MERGE WITH A DATA DICTIONARY TABLE USING THIS:
    call function 'REUSE_ALV_FIELDCATALOG_MERGE'
          exporting
               i_program_name     = repname
               i_internal_tabname = 'I'
               i_inclname         = repname
          changing
               ct_fieldcat        = fieldtab.
    if sy-subrc <> 0.
       write: 'SY-SUBRC: ', sy-subrc, 'REUSE_ALV_FIELDCATALOG_MERGE'.
    endif.
    OR JUST DISPLAY IT USING THIS:
    call function 'REUSE_ALV_LIST_DISPLAY'
          exporting
               i_callback_program       = repname
               i_callback_pf_status_set = 'PF_STATUS_SET'
               i_callback_user_command  = 'USER_COMMAND'
               i_structure_name         = 'I'
               is_layout                = layout
               it_fieldcat              = fieldtab
               i_default                = 'A'
               i_save                   = g_save
               is_variant               = g_variant
               it_events                = events[]
               is_print                 = prints
          tables
               t_outtab                 = i.
    if sy-subrc <> 0.
       write: 'SY-SUBRC: ', sy-subrc, 'REUSE_ALV_LIST_DISPLAY'.
    endif.
    ENDFORM.                               " WRITE_USING_ALV
    thanks
    mrutyun^

  • Catching the browser close event...

    Hello Fellow Portal-Heads,
    There's a nagging issue that I've been pondering (RE EP6 NW04).  In the MSS iViews there is the potential issue of a user viewing an employee and then closing the browser via the 'X' (vs. clicking the logoff link).  This 'X-ing' out of the browser leaves the viewed employee locked which is to be expected.  So... anyone have a good way to catch the 'X-ing' out of the browser and then trigger some code to perform a proper logoff?  I've tried inserting code in the masthead which catches a browser unonload() event... but it was not the smoothest operator.
    Cheers,
    Mike
    Message was edited by: Mike Yang

    Hi Mike,
    I have got a chance to work in a similar issue.The following code traps the 'X' of the browser and logoff the user.
    <script type="text/javascript">
    window.onunload = function unloadEvent()
         if (gIsPreviewMode)
              return;
         else
              if(window.screenLeft < 10004)
                     //this is refresh
              else
                     logoff();
    </script>
    Preview is taken care and the code is working fine. I am posting code so that somebody else can use it,
    Regards
    Message was edited by: Rem Swa
    This is for EP6 SP2

  • Frame window closing

    Hi friends,
    please help me in following situation.
    I have a frame1, where i have a button to open new frame2. this frame 2 opens some other frames.
    When i close main frame1, i want to trigger a event or execute a method on other frames. i tried window closing and window closed events from frame1 or frame2.
    frame2 and frame3 windows r just closing without any events when i close main frame1.
    frame2 and frame3 must extend JFrame not JDialog.
    thanks,

    make in each frame a lille method that calls the next frame (if there is one) and waits until he gets something in return...
    so 1 calls 2, 2 calls 3....
    3 is the last frame and shuts itself down, but first it returns a value to 2.
    then 2 knows it can return a value to 1 and closes itself...
    that's the thing i would do... but never tried it yet so dunno about the speed it goes....
    leme know if I helped you out.
    SeJo

  • Closing a Swing App with Window Closing Event With Dialogs On Close

    A while back I started a thread discussing how to neatly close a Swing app using both the standard window "X" button and a custom action such as a File menu with an Exit menu item. Ultimately, I came to the conclusion that the cleanest solution in many cases is to use a default close operation of JFrame.EXIT_ON_CLOSE and in any custom actions manually fire a WindowEvent with WindowEvent.WINDOW_CLOSING. Using this strategy, both the "X" button and the custom action act in the same manner and can be successfully intercepted by listening for a window closing event if any cleanup is required; furthermore, the cleanup could use dialogs to prompt for user actions without any ill effects.
    I did, however, encounter one oddity that I mentioned in the previous thread. A dialog launched through SwingUtilities.invokeLater in the cleanup method would cause the app to not shutdown. This is somewhat of an academic curiosity as I am not sure you would ever have a rational need to do this, but I thought it would be interesting to explore more fully. Here is a complete example that demonstrates; see what you think:
    import java.awt.event.ActionEvent;
    import java.awt.event.ActionListener;
    import java.awt.event.WindowAdapter;
    import java.awt.event.WindowEvent;
    import javax.swing.BoxLayout;
    import javax.swing.JButton;
    import javax.swing.JFrame;
    import javax.swing.JOptionPane;
    import javax.swing.JPanel;
    import javax.swing.SwingUtilities;
    public class CloseByWindowClosingTest {
         public static void main(String[] args) {
              SwingUtilities.invokeLater(new Runnable() {
                   public void run() {
                        launchGUI();
         private static void launchGUI() {
              final JFrame frame = new JFrame("Close By Window Closing Test");
              JPanel panel = new JPanel();
              panel.setLayout(new BoxLayout(panel, BoxLayout.Y_AXIS));
              JButton button1 = new JButton("No Dialog Close");
              JButton button2 = new JButton("Dialog On Close");
              JButton button3 = new JButton("Invoke Later Dialog On Close");
              button1.addActionListener(new ActionListener() {
                   public void actionPerformed(ActionEvent e) {
                        postWindowClosingEvent(frame);
              button2.addActionListener(new ActionListener() {
                   public void actionPerformed(ActionEvent e) {
                        JOptionPane.showMessageDialog(frame, "Test Dialog");
                        postWindowClosingEvent(frame);
              button3.addActionListener(new ActionListener() {
                   public void actionPerformed(ActionEvent e) {
                        SwingUtilities.invokeLater(new Runnable() {
                             public void run() {
                                  JOptionPane.showMessageDialog(frame, "Test Dialog");
                        postWindowClosingEvent(frame);
              panel.add(button1);
              panel.add(button2);
              panel.add(button3);
              frame.setContentPane(panel);
              frame.pack();
              frame.setLocationRelativeTo(null);
              frame.setDefaultCloseOperation(JFrame.EXIT_ON_CLOSE);
              frame.addWindowListener(new WindowAdapter() {
                   @Override
                   public void windowClosing(WindowEvent event) {
                        System.out.println("Received Window Closing Event");
              frame.setVisible(true);
         private static void postWindowClosingEvent(JFrame frame) {
              WindowEvent windowClosingEvent = new WindowEvent(frame, WindowEvent.WINDOW_CLOSING);
              frame.getToolkit().getSystemEventQueue().postEvent(windowClosingEvent);
    }An additional note not in the example -- if in the button 3 scenario you were to put the window closing event posting inside the invoke later, the app then again closes. However, as implemented, what is it that causes button 3 to not result in the application closing?
    Edited by: Skotty on Aug 11, 2009 5:08 PM -- Modified example code -- added the WindowAdapter to the frame as a window listener to show which buttons cause listeners to receive the window closing event.

    I'm not sure I understand why any "cleanup" code would need to use SwingUtilities.invokeLater() to do anything. Assuming this "cleanup method" was called in response to a WindowEvent, it's already being called on the EDT.
    IIRC, my approach to this "problem" was to set the JFrame to DO_NOTHING_ON_CLOSE. I create a "doExit()" method that does any cleanup and exits the application (and possibly allows the user to cancel the app closing, if so desired). Then I create a WindowListener that calls doExit() on windowClosingEvents, and have my "exit action" call doExit() as well. Seems to work fine for me.

  • How do I find the root cause of a NetConnection closed event?

    Hi,
    I am maintaining a large project developed in Flex/Actionscript.
    The application is using tunneling (RTMPT), and we often get Netconnection "closed" events.
    There is no problem with the physical network.
    I think the event may be caused by either a TCP/HTTP/RTMP event, or may be caused by
    some function in the client calling close() on the connection.
    How can I find the root cause of the "closed" event being thrown?
    Thanks,
    David

    Thanks for the information.  It is helpful but it seems there must be a specification of
    what the client side is expecting, independent of any server implementation. 
    When I say client side, I mean the Adobe communication libraries.
    Where is the specification or source code for how the client libraries treat HTTP tunneled requests and responses?
    One question in particular:  How does the client side library treat a
       Connection: Keep-Alive
    versuse
       Connection:close
    HTTP header setting?

  • How to get the closing event (not closed) of Dialog control

    Hi All,
    I have one requirement, that I have to close the Dialog box in an animated way like on clicking of the Dialog close button the popup has to close from top to bottom in a slide effect.
    sap.ui.commons.Dialog
    When I tried closed method of Dialog, it is calling only after dialog box closed but, I need the closing event rather closed event.
    I am putting a UI5 view in Dialog as I need some custom/dynamic content in the dialog.
    Please suggest the solution for this.
    Thanks & Regards,
    Pavan Thirunamala,
    [Moderator Message - Please do not provide contact information like Phone Number etc in the discussion message. It has been removed.]
    Message was edited by: Chandrashekhar Mahajan

    JS Bin - Collaborative JavaScript Debugging&lt;/title&gt; &lt;link rel=&quot;alternate&quot; type=&quot;application/jso…
                sap.ui.getCore().getEventBus().subscribe("sap.ui","__beforePopupClose",
    function(channel, event, params)
      debugger;   
    $(params.domNode).animate({
                      opacity : 1,
                  height : 0

  • NetConnection.Connect.Closed event not triggered in Vista FF3 when in fullscreen mode

    Hello Pals -
    I'm trying to handle the net connection drop and provide some kind of visual cue to user. For this I'm listening to NetConnection.Connect.Closed event and when its triggered, I take further steps. The events are triggered in Vista FF3(window mode)/IE7 but in Vista FF3 full screen mode, the event is not triggered. I forcefully disconnect the network cable to see the NetConnection.Connect.Closed event is triggered.
    I have following piece of code to listen to the event,
    nc = new NetConnection;
    nc.addEventListener(NetStatusEvent.NET_STATUS, onStatus, false, 0, true);
    nc.connect();
    public function onStatus(event:NetStatusEvent):void {
    trace("Status " + event.info.level + " : " + event.info.code);
    The function onStatus should be called whenever there is a status change in net connection. The events are not triggered in Vista FF3 full screen mode. Please share your views/ideas about this here. Thanks in advance. Please let me know incase more information is required.

    The problem decribed as above was caused by a fragile and eventually broken soldered connection on the curcuit board. My local dealer replaced the curcuit board and everything works fine again.
    I still wonder how that happend. I did not try to bend my MacBook and it did not fall of my desk.
    Thanks for reading.

  • Default time frame for ICAL events

    Ever since I upgraded to Lion, the default time frame for ICal events has been set to "entire day".  Is there any way to change this?

    Hi,
    If you add a time to the event description, like "meeting  11am tomorrow", it should create an event (with the title "meeting" on tomorrows date at 11am with a duration of 1 hour.
    Best wishes
    John M

  • How do I stop iPhoto from repeatedly closing Event title boxes when I am in the middle of entering a title?

    How do I stop iPhoto from repeatedly closing Event title boxes when I am in the middle of entering a title?
    This problem started several months ago. I have tried typing more slowly and typing faster; neither help.
    It now takes me about four attempts to complete a title of about twelve characters, achieving about three characters on each attempt.
    I am running iPhoto 9.4.3 on OS X 10.8.3 on a 2.93 GHz Intel Quad-Core i7 iMac with 12 GB of DDR3 memory.

    As a Test:
    Hold down the option (or alt) key and launch iPhoto. From the resulting menu select 'Create Library'
    Import a few pics into this new, blank library. Is the Problem repeated there?

  • How to display internal frame on click event from another internal frame

    hi me developing desktop application in netbean. i have some problem. plz reply me as soon as possible. feedback me on [email protected]
    1. I want to invoke an Internal Frame by click event that is in another internal frame. how i do it. I tried my best
    2. how can i call reports (ireports) from swing application

    Read the JInternalFrame API. You will find a link to the Swing tutorial on "How to Use Internal Frames" which contains a working example.

  • Detect window closing event in AIR application

    How do I detect the window closing event in an AIR app? Tried
    the following.
    deactivate and windowDeactivate events in the
    WindowedApplication tag.
    addEventListener(Event.CLOSING, onClose);
    addEventListener(AIREvent.APPLICATION_DEACTIVATE onClose);
    addEventListener(AIREvent.WINDOW_DEACTIVATE, onClose);
    None of them seem to work.
    Any ideas?
    Thanks
    CS

    The following works for me:
    <mx:WindowedApplication xmlns:mx="
    http://www.adobe.com/2006/mxml"
    layout="absolute"
    closing="traceEvent(event)"
    windowDeactivate="traceEvent(event)"
    applicationDeactivate="traceEvent(event)">
    <mx:Script>
    <![CDATA[
    public function traceEvent(event:Event):void{
    trace(event.type);
    ]]>
    </mx:Script>
    </mx:WindowedApplication>
    As does:
    <mx:WindowedApplication xmlns:mx="
    http://www.adobe.com/2006/mxml"
    layout="absolute"
    applicationComplete="init()">
    <mx:Script>
    <![CDATA[
    import mx.events.AIREvent;
    public function init():void{
    this.addEventListener(Event.CLOSING, traceEvent);
    this.addEventListener(AIREvent.WINDOW_DEACTIVATE,
    traceEvent);
    this.addEventListener(AIREvent.APPLICATION_DEACTIVATE,
    traceEvent);
    public function traceEvent(event:Event):void{
    trace(event.type);
    ]]>
    </mx:Script>
    </mx:WindowedApplication>

Maybe you are looking for

  • DBIF_RSQL_SQL_ERROR while creating the Info record

    Hi, When i try to create the infor record ,it is giving this error while saving the record. Runtime Errors         DBIF_RSQL_SQL_ERROR Except.                CX_SY_OPEN_SQL_DB Date and Time          12/15/2010 09:47:05 Short text      SQL error in th

  • Iphoto will not open since upgrading to OS X 10.10

    upgraded to yosemite on my iMac and now i can not open iPhoto to do downoads

  • Oracle BAM and snmp

    Hi at all, Data passed to BAM (Oracle Suite 11g) from SNMP, it's possible? tnx.

  • BDC - help with passing values

    Hi, The BDC code works fine when the value(3) or any value is hard coded. But it is not working if I use 'RMQAM-AKTIV(p_insty)' where p_insty is the parameter value entered at selection screen. Please let me know how to pass this value. perform scree

  • JQeury Clash