CatOS image upgradation in Cisco 6509

what is the procedure for upgrading the CatOS in Cisco 6509, can any provide step by step configuration?

The link below has the step-by-step procedure to upgrade the CatOS image.
http://www.cisco.com/en/US/products/hw/switches/ps700/products_configuration_example09186a0080116ff0.shtml
HTH,
Sundar
*Please rate all helpful posts.

Similar Messages

  • LLQ priority issue after upgrading to Sup32 on Cisco 6509

    Hi,
    I have 1x Cisco 6509 with Sup2 and MSFC2 and it is running on IOS (c6k222-jk9sv-mz.122-17d.SXB11).
    I have following policy map :
    Policy Map VOIP
        Class IPPHONE
          priority percent 75
    and the following command on each interface:
    service-policy output VOIP
    those configuration are working fine on SUP2 with MSFC2 but last week I tried to upgrade the SUP2 to SUP32 on the switch and upgrade the IOS to the latest version (s3223-adventerprisek9-mz.122-33.SXJ4)
    but when I try to put service-policy output VOIP on each physical interface I am getting the following error:
    "Priority command is not supported in output direction for this interface"
    and when I try to add service-policy output VOIP on a VLAN interface I am getting following error:
    MQC features are not supported in output direction for this interface.
    Please let me know if I need to change something after upgrading to SUP32.
    Thanks

    Hi
    Hi
    Sup32 uses PFC3B for Hardware forwarding and implemenation of features like qos, acl, netflow etc
    PFC QoS does not support these policy map class commands:
    •bandwidth
    •priority
    •queue-limit
    •random-detect
    •set qos-group
    •service-policy
    http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/ios/12.2SX/configuration/guide/qos.html
    Thanks
    Raju

  • Bootloader and IOS image into a Catalyst 6509 running hybrid mode

    Hi all,
    I have a Catalyst 6509 running CatOS and IOS (hybrid mode)
    The chassis is based on a SUP1A and a MSFC2
    The MSFC is using images:
    boot system bootflash:c6msfc2-is-mz.121-2.E
    boot bootldr bootflash:c6msfc2-boot-mz.121-2.E
    I would like to know if is possible to add the next command to the MSFC configuration in order to load the new image before erase the old one, even while the chassis boot using the old bootloader image:
    boot system tftp c6msfc2-pk2o3sv-mz.121-26.E2.bin 10.10.5.15
    Thanks.

    Thanks Amit, thanks Ankur,
    Yeah! I know about the limits of the bootflash space as the PCMCIA option.
    It is a bit complicated to explaint the situation here but I will try.
    Neither the actual CatOS or IOS will recognize the new PCMCIA we bought to this upgrade. :P
    First, I will upgrade CatOS using rommon and xmodem command in order to execute a new catos release that can view the PCMCIA, then I will format it and I will copy the new catos image and the new ios image there.
    Then I will change the catos boot config and I will do a reset.
    I must do that because the new release don't enter into the bootflash and the actual CatOS don't support boot from the network :P. It is CatOS 5.5.1 :PPP
    After that, I need also to upgrade the MSFC because as I read that the actual IOS won't see the PCMCIA filesystem. In order to do that I would like to prepare the MSFC to boot from a TFTP server and then modify the configuration to boot from sup-slot0: forever :)
    Let me know what do you think about this steps.

  • Cisco 6509 with 10G Module

    Hello,
    We have Cisco 6509 Core Switch with following details & we need to install WS-X6716-10T-3C module in int.
    Can some body advise which slot number i should use in 6509 ?
    Do i need to upgrade supervisor engine IOS for this ?
    Is it hot swapable module & can i install this module in production ?
     6509_CORE#sh ver
    Cisco IOS Software, s72033_rp Software (s72033_rp-ADVENTERPRISEK9_WAN-M), Version 12.2(33)SXI6, RELEASE SOFTWARE (fc4)
    Technical Support: http://www.cisco.com/techsupport
    Copyright (c) 1986-2011 by Cisco Systems, Inc.
    Compiled Mon 28-Mar-11 12:09 by prod_rel_team
    ROM: System Bootstrap, Version 12.2(17r)SX7, RELEASE SOFTWARE (fc1)
    6509_CORE uptime is 2 years, 30 weeks, 1 day, 3 hours, 13 minutes
    Uptime for this control processor is 2 years, 30 weeks, 1 day, 1 hour, 44 minutes
    Time since AUB_CORE switched to active is 2 years, 30 weeks, 1 day, 1 hour, 44 minutes
    System returned to ROM by  power cycle at 11:55:23 UTC Wed Apr 27 2011 (SP by power-on)
    System restarted at 11:16:22 AST Sun Jun 26 2011
    System image file is "sup-bootdisk:s72033-adventerprisek9_wan-mz.122-33.SXI6.bin"
    Last reload reason: Reload Command
    cisco WS-C6509-E (R7000) processor (revision 1.5) with 983008K/65536K bytes of memory.
    Processor board ID SMC1426001S
    SR71000 CPU at 600Mhz, Implementation 0x504, Rev 1.2, 512KB L2 Cache
    Last reset from s/w reset
    4294967295 Ethernet interfaces
    33 Virtual Ethernet interfaces
    150 Gigabit Ethernet interfaces
    100 Ten Gigabit Ethernet interfaces
    1917K bytes of non-volatile configuration memory.
    8192K bytes of packet buffer memory.
    65536K bytes of Flash internal SIMM (Sector size 512K).
    Configuration register is 0x2102
    6509_CORE#sh module
    Mod Ports Card Type                              Model              Serial No.
      1   24  CEF720 24 port 1000mb SFP              WS-X6724-SFP       SAL1430P2QU
      2   48  CEF720 48 port 10/100/1000mb Ethernet  WS-X6748-GE-TX     SAL1429N6XB
      3   16  CEF720 16 port 10GE                    WS-X6716-10GE      SAL1430NYUE
      4   16  CEF720 16 port 10GE                    WS-X6716-10GE      SAL1430NX5A
      5    5  Supervisor Engine 720 10GE (Active)    VS-S720-10G        SAL1430NUJE
      7   16  CEF720 16 port 10GE                    WS-X6716-10GE      SAL1645RJTF
    Mod MAC addresses                       Hw    Fw           Sw           Status
      1  d0d0.fd62.d9e0 to d0d0.fd62.d9f7   4.4   12.2(18r)S1  12.2(33)SXI6 Ok
      2  c84c.75b8.596c to c84c.75b8.599b   3.4   12.2(18r)S1  12.2(33)SXI6 Ok
      3  001f.6cac.11d0 to 001f.6cac.11df   1.0   12.2(18r)S1  12.2(33)SXI6 Ok
      4  5475.d06e.0988 to 5475.d06e.0997   1.0   12.2(18r)S1  12.2(33)SXI6 Ok
      5  001e.4a7f.3068 to 001e.4a7f.306f   3.2   8.5(4)       12.2(33)SXI6 Ok
      7  fc99.4736.2d80 to fc99.4736.2d8f   1.1   12.2(18r)S1  12.2(33)SXI6 Ok
    Mod  Sub-Module                  Model              Serial       Hw     Status
      1  Distributed Forwarding Card WS-F6700-DFC3C     SAL1430P282  1.4    Ok
      2  Centralized Forwarding Card WS-F6700-CFC       SAL1430NRAS  4.1    Ok
      3  Distributed Forwarding Card WS-F6700-DFC3C     SAL1430P26L  1.4    Ok
      4  Distributed Forwarding Card WS-F6700-DFC3C     SAL1430NZRM  1.4    Ok
      5  Policy Feature Card 3       VS-F6K-PFC3C       SAL1429N6B7  1.1    Ok
      5  MSFC3 Daughterboard         VS-F6K-MSFC3       SAL1430NN3R  5.0    Ok
      7  Distributed Forwarding Card WS-F6700-DFC3C     SAL1644RAZF  1.5    Ok
    Mod  Online Diag Status
      1  Pass
      2  Pass
      3  Pass
      4  Pass
      5  Pass
      7  Pass

    Hello cmarva,
    I got power requirement from core switch:
    6509_CORE#show power
    system power redundancy mode = redundant
    system power total =     3795.12 Watts (90.36 Amps @ 42V)
    system power used =      2748.06 Watts (65.43 Amps @ 42V)
    system power available = 1047.06 Watts (24.93 Amps @ 42V)
                            Power-Capacity PS-Fan Output Oper
    PS   Type               Watts   A @42V Status Status State
    1    WS-CAC-4000W-INT   3795.12 90.36  OK     OK     on
    2    WS-CAC-4000W-INT   3795.12 90.36  OK     OK     on
                            Pwr-Allocated  Oper
    Fan  Type               Watts   A @42V State
    1    WS-C6509-E-FAN      210.00  5.00  OK
                            Pwr-Requested  Pwr-Allocated  Admin Oper
    Slot Card-Type          Watts   A @42V Watts   A @42V State State
    1    WS-X6724-SFP        162.96  3.88   162.96  3.88  on    on
    2    WS-X6748-GE-TX      325.50  7.75   325.50  7.75  on    on
    3    WS-X6716-10GE       457.80 10.90   457.80 10.90  on    on
    4    WS-X6716-10GE       457.80 10.90   457.80 10.90  on    on
    5    VS-S720-10G         338.10  8.05   338.10  8.05  on    on
    6    (Redundant Sup)       -     -      338.10  8.05  -     -
    7    WS-X6716-10GE       457.80 10.90   457.80 10.90  on    on
    system auxiliary power mode = off
    system auxiliary power redundancy operationally = non-redundant
    system primary connector power limit =   10920.00 Watts (260.00 Amps @ 42V)
    system auxiliary connector power limit = 10500.00 Watts (250.00 Amps @ 42V)
    system primary power used =              2748.06 Watts (65.43 Amps @ 42V)
    system auxiliary power used =            0 Watt
    As per Cisco document i require this power WS-X6716-10T-3C: 509.3W (12.1A @ 42V) & from output available power is system power available = 1047.06 Watts (24.93 Amps @ 42V)
    Looks like im good to go. Can you verify please ?
    http://www.cisco.com/c/en/us/products/collateral/switches/catalyst-6500-series-switches/product_data_sheet09186a00801dce34.html
    Regards,

  • ACS SE base image UPgrade

    HI,
    We have upgraded the ACS SE 1112 as following.
    Cisco Secure ACS : 4.0.1.42  to 4.1.1.23
    Appliance Management Software:4.0.1.42to 4.1.1.23
    Appliance Base Image needs to upgrade from 3.3.1.8 to 4.1.1.4 but we are not able to download the package at download centre as it is not available.
    Kindly suggest for base image upgrade.
    Regards,

    It should work as long as you don't miss anything, and yes you are supposed to install an agent that matches the version you are running. You might want to go ahead and put the latest updates on the ACS before you put it into operation. The process is kind of different than other updates. You might want to read my other ACS posts. I recently killed one of my ACS boxes because I did not install the CSUPdate cumulative patch before installing the lastest patch of the same rev level. (i.e. read directions carefully). Make sure you do an FTP backup before updating the software. If anything goes wrong you could have to reimage the box. There were lots of bug fixes in the updates since 4.1.1.
    Randy

  • Wireless Controller Image Upgradation

    Cisco recommends image upgrade procedure on 4402 WLC to the latest release 4.1 to be performed in three steps:-
    1)3.1.105.0 ------>3.2.78.0
    2)3.2.78.0 ------->3.2.195.13
    3)3.2.195.13------>4.1.185.0
    Unfortunately, while upgrade from 3.1.105.0 ------>3.2.78.0
    I got the below error message as shown on both CLI and GUI as well.
    "TFTP Failure while storing in flash!"
    I have tried Tftpd32 which Cisco recommends also tried other TFTP versions a couple of times but resulted in the same error.
    Could someone please suggest TFTP server software package which will support file transfers larger than 32 MB ?
    Awaiting your reply and valuable suggestions.

    Hey Sanoj,
    I've got similar restrictions on some of my controllers. One thing to keep in mind is that the controller won't actually load the new OS until you reboot. Depending on how restrictive your change control process is, you may be able to attempt loadint the software outside of your change window. Once you have a successful tftp transfer, you can schedule a window for a reboot, which will actually load the new OS. I wouldn't leave too much time between the tftp transfer and then reboot, but I understand your frustration with the tftp transfers... I have about an 80% failue rate on tftp transfers (using tftpd32) over any wan link, no matter how high I set my timeouts and retransmits.

  • Image upgrade for 2811-Error SWIM5004

    Hi ,
    While doing the image repository of the 2811 routers I am receiving the below error, these errors only appearing when I am doing image upgrade/repository for 2811 routers only.
    We cannot use the snmp write due to company policy. If any other solution exist then please advise me.
    "SWIM1125: Failed to copy the image to Flash due to the reason - SWIM5004: Cannot initiate SNMP-set operation.
    The SNMP Write Community String might be wrong.
    Check whether the correct SNMP Write Community String is entered in Device and Credential Repository..
    Retry the operation. If the problem persists, check the Bug Toolkit application for any known issues on the running image version.
    We are using SNMP v3 and have checked the SNMP settings ,it is ok.
    We have also verified that the TFTP service is working properly on the Ciscoworks server.
    I am using
    LMS:3.2
    RME:4.3.1
    THANKS

    If you cannot use SNMP write access, you will not be able to use SWIM to upgrade this 2811 using TFTP.  In order to upgrade the 2800s, RME will perform an SNMP Set of the CISCO-FLASH-MIB to trigger a copy of the image from the RME server to the router.  You can use SCP instead in which case the device will be the server.  In order to do this, you need to have SSH configured on the device, and the user configured in DCR must be allowed to login to the device with enable level access.

  • Cisco 6509 with Reliability 255/255, txload 238/255, rxload 8/255 interface

    Hi there,
       I'm having an issue with my Cisco 6509. One of Internet configured as trunk Interface direct with a HP7500 is showing reliability 255/255, txload 238/255, rxload 8/255.
       The Issue is that my Cacti Server show me that only 10% of the link is in use but if you look at txload you can see that almost 100% of the bandwidth is in use..  
      What can I do in order to figure out what's going on with this Interface.  I'm thing about to put wireshark and configure a port monitor in order to capture the packets.
    Is anyone has any tip to do a troubleshoot with this issue??
    SWITCH01#show int port-channel 10
    Port-channel10 is up, line protocol is up (connected)
      Hardware is EtherChannel, address is c47d.4fbf.a8c2 (bia c47d.4fbf.a8c2)
      Description: CORECISCO_X_COREHP
      MTU 1500 bytes, BW 2000000 Kbit, DLY 10 usec,
         reliability 255/255, txload 238/255, rxload 8/255
      Encapsulation ARPA, loopback not set
      Full-duplex, 1000Mb/s
      input flow-control is off, output flow-control is unsupported
      Members in this channel: Gi8/19 Gi8/20
      ARP type: ARPA, ARP Timeout 04:00:00
      Last input never, output never, output hang never
      Last clearing of "show interface" counters 1w0d
      Input queue: 0/2000/0/0 (size/max/drops/flushes); Total output drops: 0
      Queueing strategy: fifo
      Output queue: 0/40 (size/max)
      5 minute input rate 66043000 bits/sec, 23041 packets/sec
      5 minute output rate 1871148000 bits/sec, 186439 packets/sec
         15127300343 packets input, 6121405739799 bytes, 0 no buffer
         Received 232321316 broadcasts (161670914 multicast)
         0 runts, 0 giants, 0 throttles
         0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
         0 watchdog, 0 multicast, 0 pause input
         0 input packets with dribble condition detected
         118621325538 packets output, 141124879219641 bytes, 0 underruns
         0 output errors, 0 collisions, 0 interface resets
         0 babbles, 0 late collision, 0 deferred
         0 lost carrier, 0 no carrier, 0 PAUSE output
         0 output buffer failures, 0 output buffers swapped out
    SWITCH01#
    Regards 
    Adriano

      This pretty much tells you your port channel is pretty full.  How many ports in the channel?
    5 minute input rate 66043000 bits/sec, 23041 packets/sec
      5 minute output rate 1871148000 bits/sec, 186439 packets/sec

  • Upgrade from Cisco Prime infrastructure verion 2.0 to 2.1

    Request you all to please let me know if i have to install point patch before upgrading the cisco prime infrastructure 2.0 to 2.1.

    After moving to 2.1, there is a 2.1.1 point patch currently available.
    You should install that and the latest device package (4.0 as of this posting).
    As always, the Release Notes are the best place to check the current available updates.

  • Yesterday after upgrading the Cisco AnyConnect app, it stopped working; Today, the app is not available anymore from the apple store, what happened?

    Yesterday after upgrading the Cisco AnyConnect app, it stopped working; Today, the app is not available anymore from the apple store, what happened?

    There is an explanation in the following link in the section "What's new in version 3.0.09440" that there was a problem with the update. It's available again now. https://itunes.apple.com/us/app/cisco-anyconnect/id392790924?mt=8

  • Upgrading from cisco LMS 3.0 to a latest version

    Hello,
    Upgrading from cisco LMS 3.0 to a higher version.
    Whatdoes it require?.
    What is the current version?
    What do we need for upgrading?
    Are there specific codes or new need to buy new products?
    In case of buying new products, which are the configurations?

    H Malik,
    You are correct! Latest version is Cisco prime LMS 4.2. There is no direct upgrade from LMS 3.x to LMS 4.x.
    The procedure is simple:
    Take backup orf old LMS --> Un-install (if same machine)--> Install new LMS --> Restore backup to get old data.
    You would need to purchase new license for it.Cisco Prime LMS is now part of the Cisco Prime Infrastructure bundle and is not orderable separately. Cisco Prime Infrastructure bundle follows a size-based incremental licensing model. Device licenses can be combined and added when applied to a single server installation instance. Customers have the option of adding incremental licenses for additional devices as their network grows.Refer to the Cisco Prime Infrastructure Ordering Guide located at http://www.cisco.com/go/primeinfrastructure for the exact part number that matches your requirement and placing the order.
    Currently even SmartNet or SAS contracts does not cover major upgrades from LMS 2.x and 3.x; an upgrade part number will need to be purchased to move to Cisco Prime LMS 4.2. These upgrade part numbers reflect a significant discount to protect customers' investment in the Cisco Prime product line.
    The data migration process will vary depending on the LMS version from which the data need to be migrated. Migrating data to LMS 4.2:
    • LMS 4.2 supports local upgrade or direct inline upgrade only from LMS 4.0.1 and LMS 4.1.
    • LMS 4.0 customers are encouraged to install LMS 4.0.1 before doing inline upgrade to LMS 4.2.
    • LMS 3.2 and LMS 3.2 Service Pack 1 customers can do a remote upgrade through the LMS backup and restore mechanism.
    • LMS 3.1, LMS 3.0, LMS 3.0 December 2007 Update, LMS 2.6, and LMS 2.6 Service Pack 1 customers need to do a remote upgrade to LMS 4.0.1 and then upgrade to LMS 4.2.
    -Thanks
    Vinod

  • Regarding LACP commands on Cisco 6509 to connect server

    Hi All ,
    We have to connect two servers to cisco 6509 (sup720 with MFFC R7000)  switches and we have to configure LACP on the 6509 to bundle two ports to get 2 Gbps through put.
    Each server has four NIC ports ..out of which two ports will be connected to Switch 1 ( active ) and remaning two ports will be connected to switch 2 ( standby).
    We are going to use below commands for LACP on both the switches.Apart from below commands do we need to have any other commands to make LACP to work as soon as we connect the servers.
    Switch 1 :
    set channelprotocol lacp 1
    set port lacp-channel 1/1-2 73
    set port lacp-channel 1/1-2 mode active
    Set port vlan 10 1/1-2
    set spantree bpdu-guard 1/1-2 enable
    set port lacp-channel 1/9-10 85
    set port lacp-channel 1/9-10 mode active
    Set port vlan 10 1/9-10
    set spantree bpdu-guard 6/9-10 enable
    On the MFFC we have so many vlans along with vlan 10
    int Vlan 10
    ip address 10.10.10.2 255.255.255.0
    standby 10 ip address 10.10.10.1
    standby 10 timers 1 3
    standby 10 priority 200
    same series of port will be used on Switch 2 to connect servers.
    Servers support LACP protocol only.
    diagram is enclosed...If any suggetions on this would be appreciated..
    Thanks ,
    M S K       

    Interesting I thought all sup 720's were non hybrid and used IOS only .  Guess you learn something everyday. Looks like it should work with what you
    have as long as the servers are setup with lacp in a active/standby mode.

  • Image upgrade failed

    Hello,
    We are running RME 3.4.1, when doing an image upgrade we are receiving the following error :
    Loading image file to flash device : rep_sw_1054534997912433081 -->  flash:c1200-k9w7-tar.123-8.JEC2.tar using TFTP
    Loading image file to flash device :  rep_sw_1054534997912433081 --> flash:c1200-k9w7-tar.123-8.JEC2.tar using TFTP 
    Error loading image to flash.
    Error Message:
    SWIM1125: Failed  to copy the image to Flash due to the reason - copyFileOpenError :invalid file  name; file not found in partition.
    Retry the  operation. If the problem persists, check the Bug Toolkit application for any  known issues on the running image version.
    Is this another bug ?
    Many thanks,
    Lieven Stubbe
    Belgian Railways

    What is the current image running on the device?  It would be helpful to see a sniffer trace filtering on all traffic between the RME server and the device while the SWIM job runs.

  • ThinkPad USB 3.0 dock network port has problems with our Cisco 6509 switch

    We purchased a ThinkPad USB 3.0 dock for and X1 carbon and the main issue we are having is the network port does not seem to work with our Cisco 6509 switch. I tried updating the firmware on the dock but it still hasn't fixed the issue. I was wondering if anyone else had run into this problem with any other networks out there.

    I'm seeing the same issue with a ThinkPad W520.  When I connect my ethernet cable directly to the laptop, my internet speeds are on par with my service provider of 18 Mbps.  When I move that cable to the dock, I will only see 1.5 Mbps.  I have two displays attached to the dock and I'm running Windows 7.  I've updated the dock firmware and have installed the latest system drivers.  Is there anything else to try?

  • Ciscoview Cisco 6509 VSS power supply LED indicators incorrect

    Hello all
    i am experiencing the following problem.
    In the Ciscoview, the LED indicators of the power supply of Cisco 6509 VSS are represented incorrectly. All power inputs and fans are okay actually. however, in the ciscoview, there is only 1 green "INPUT OKAY" for each power supply. And "FAN OKAY" LEDS are off on Active chassis.
    Any assistance would be greatly appreciated.
    LMS 4.1
    IOS Version 12.2(50)SY1
    Device Package:
    38.
    Cat6000
    12.0
    Cat6000 Package
    39.
    Cat6000IOS
    37.0
    Cat6000IOS Device Package

    Check the PS at the back, is there a light?  If there's no light, then you need to RMA the PS as it could be faulty.
    If there's a light on the PS, then you need to RMA the switch. 

Maybe you are looking for

  • Random selection from a list

    I'm setting up a multiple-choice question, and I want to re-arrange the position of the button sprites representing the correct answer and distractors. I can randomly select one of the sprites via gDistractorLoc = random(4). The random function fails

  • Need to Upgrade to RHEL 5.5 on 10.2.0.4.0 DB RAC Servers

    Hello, We need to upgrade the RHEL 4.x OS to RHEL 5.5 on all of our 2-node 10.2.0.4.0 RAC DB servers. I realize that RHEL doesn't support upgrades from MAJOR versions like this in terms that only DB re-linking activities need to be done. As a result,

  • How to reset my eligibility upgrade on the web?

    The unresolved problem I have concerns my iPhone. I returned an iPhone 6 to the Apple store on Sept 24 to exchange for a Plus. I was told at the store that I could order an iPhone 6 Plus immediately online. When I tried to do that I received a messag

  • Moving: G3 to Intel & wireless to wired?

    Hello all, I am due to order my 2 new 24" iMacs this week (yipee!) and will be, in effect moving from a G3 iBook and G3 iMac on an Snow ABS. Currently I have 8Mb broadband. I am wondering, given that these 2 are desktops, whether I need/should to upg

  • Need to create a DVD