CATS - Data Transfer to Target Components via CATA - Error "No Data for Trf

Hello
I am recording hours via CAT2 on Network Activity. These hours are then approved.
However, when I run CATA to transfer the hours to CO and PS, I get popup information "No Data for Transfer".
When i proceed further , i get another popup saying all records were read and saved successfully, and no. of confirmations generated.
However, when i run CJI3, I do not see any Actual cost line items.
Please help
JG

Hello Joy,
(1) Perhaps you have on your profile on CAC1, the "Immediate Transfer to HR" flag set.
This way you have the "Release on Saving" flag set, all the time you save data, it gets transferred directly.
(2) But, I see that you are having the issue with the CO and PS, so I highly suggest you to check on if the data is on the interface tables.
  a. First you should make sure that the data exists on CATSDB with Status 30.
  b. Then, you should check the data on CATSPS (Interface table for PS) and CATSCO( interface table for CO).
  c. If you don't have the data on these tables there should be no record after all to transfer.
Regards,
Bentow.

Similar Messages

  • Problem's in data transfer  to target components in SAP PS - CATS

    Hi all
    I am trying to transfer data from CATS to PS and CO for month end closing .
    I have checked the budget in planned/actual/assigned report, and the
    WBS has sufficient budget.
    T-code used is CATA, and we are using a varient, and while transfering the data
    we are mentioning the cost center instead of employee number.
    The following message is displayed which is show in the attachement.
    Can  any body please let me know solution for this.
    What is difference between "Budget exceeded" and "Budget almost exhausted" ?
    How to check the error in the document ?

    "What is difference between "Budget exceeded" and "Budget almost exhausted" ?"
    The tolerance limits have been configured in such a way that when the budget reaches a certain percentage system will pop errors as you are seeing. For e.g. In your case the system might be issuing the message "Budget Exceeded" when 100% of the defined budget is reached. Similarly, system is issuing  the message "Budget almost exhausted" when 90% of the defined budget is reached. Budget almost exhausted message will still allow you to go ahead with the transfer provided you first correct the error in the document.
    "How to check the error in the document ?"
    Try to double click on the error message. That should take you to the details of the error.
    Why are you using the cost center instead of the Personnel number in order to transfer the hours? General practice is to use the personnel number.
    Check tcodes CN30,  COFC and see if you can get to the details of the error.

  • Data Transfer Workbench can copy sales & purchase modules's data?

    Hi,
    Just wondering that,any way to copy the Sales & Purchase Modules's data from existing company to new company? Copy Express can't do it. But how about Data Transfer Workbench can copy?
    Thanks
    Regards,
    Danny
    Edited by: Danny Gan on Mar 18, 2008 5:21 AM

    Danny,
    How many field from the ORDR or RDR1 have to exported depends on the business logic implemented and what was being used.  No one can really provide a standard set of 5 or 10 fields as you know the clients business better than anyone in the Forum.
    If the Client used User fields then data from the user fields should also be exported.
    The base fields from ORDR would be CardCode, DocDate, DocDueDate, Transpcode (shipping code), SlpCode, GroupNum (Payment terms code), etc.
    Similarly on RDR1, ItemCode, Quantity, Price and any additional row level information that may pertain to their business
    Suda

  • CATA: time sheet: transfer to target components

    Could you please please give me an overview of what CATA (t-code) does?
    I have done some config in sandbox:
    I booked time in cat2 with a sender cost ctr + activity type and receiver cost center in ECC 6.0. With out running cata (t-code), I was able to see the actuals in cost center actual line item report and PS.
    I did not understand what was the purpose of CATA ?
    Thank you
    Ravi

    You need to run cata if you want to pass the Entries to all the components which you implemented,
    Else you can use CAT6 for HR exclusive ,
    Let me know the requirement
    Thansk
    Shetty

  • Internal Data Transfer to Funds Management - Version Management Error

    Hi All,
    We are trying to convert the open PO's in our system that were created before FM was implemented, and that are to be converted now before the MIGO stage.
    We are using the following steps:
    1) Select the document
    2) Convert the worklist.
    We had done the first step, and faced no issues. During the conversion of the worklist, we face the following error
    Message ID - MEPO;Message Number - 813; Version Management of purchase order still faulty.
    Message ID - MEDCM; Message Number - 4; Enter short text for version
    Message ID - MEDCM; Message Number - 3; Enter reason for change for version
    In the Control Data for each of the Document Type, the control data, Version Active and Version 0 OK are activated.
    Can someone kindly suggest what could have possibly gone wrong here ?
    Regards,
    Wy

    Hi All,
    Just to clarify, I went through note 800784 and found that in our system
    1. None of the fields - 'Reason,' 'Description,' 'Req By,' 'Req By Ext' or 'Post Date' -  is a required entry in the version management  field selection
    2. None of the fields - EKPO-ELIKZ or EKPO-EREKZ or EBAKZ - are set as Version-Relevant Fields of Purchase Requisitions.
    Cant figure out why I am not able to assign the fund centre and commitment item here, although I am able to perform MIGO and MIRO on that.
    Regards,
    Wy

  • External Data Transfer to FI-SL Using RGUREC00 - Is Plan Data Supported?

    Hi,
    I  copied standard  program (RGUREC00- to load PLAN data into FI-SL )  to z program and changed as per the requirement from client but it dosen't work for 'PLAN Data', it works only for 'Actuals'.
    Is there any other program to load PLAN data ?
    Please guide me.

    Check RKEPCU20.
    Rob

  • Unable to connect via "Data Transfer" Mode On N95 ...

    Its been happening for a little while now. When i plug the USB cable in, it asks if i wanna connect via PC Suite, Data Transfer etc
    When i click Data Transfer it says the following:
    "Unable to activate Data Transfer Mode. Mass Memory is in use by another application"
    Does anyone know the fix for this problem?
    Many thanks
    Message Edited by tiff777 on 06-Nov-2008 07:56 PM
    Message Edited by tiff777 on 06-Nov-2008 07:57 PM

    Hi There
    Im not sure this would work for you all but i came accross this discussion after suffering the same problem and after pulling my hair out i finally solved it and thought it was only fair i posted how.
    I had tried all options on here apart from deleteing everything off my memory card ( i wasn't keen on this option ) i checked the running apps and it just showed that standby was running,
    So i thought i would try uninstalling recently installed item one by one, i had recently installed some  software called CALL RECORDER  and although it was not showing up that it was running it was in the background after deleting this the problem was solved ,
    So try and think if there are any apps that you have installed that may be running in the background but not showing up , i would advise deleting these one by one as i did and if it still doesnt work you can reinstall it ,
    hope this helps
    BUT EVEN AFTER ALL THIS I STILL LOVE MY N95 8GB !!!!!!!!!!!!!!!!!!!!!!!

  • Data S Default data transfer Options

    Hi
    What do the below mentioned terms mean in infopackage-Schedular--Data S Default data transfer
    1Max size of datapakcet in kbytes
    2Max no of dailogues process for sending data
    3No of data packet per info idoc
    Please help me with an example and what importance it has when we increase/ decrease the lengh of the above 3 mentioned do we have any interconnection in all three or they are all independent.
    Thanks
    Puneet

    Hello Puneet,
    These are some standard BW Settings done in transaction SPRO.
    SPRO ->SAP Customizing Implementation Guide->SAP NetWeaver->SAP Business Information Warehouse->Links to Other Systems->Maintain Control Parameters for the data transfer
    Maximum size of a data packet in kilo bytes.
    The individual records are sent in packages of varying sizes in the data transfer to the Business Information Warehouse. Using these parameters you determine the maximum size of such a package and therefore how much of the main memory may be used for the creation of the data package.
    SAP recommends a data package size between 10 and 50 MB.
    Frequency with which status Idocs are sent
    With this frequency you establish how many data IDocs should be sent in an Info IDoc.
    Maintain Control Parameters for the data transfer
    Standard settings
    For SAP source systems, you change the control parameter settings in the transaction SBIW (Customizing for Extractors), under Business Information Warehouse -> General Settings -> Control Parameters -> Maintain Control Parameters for Data Transfer .
    Activities
    1. Maximum size of data packages
    For data transfer into BW, the individual data records are sent in packages of variable size. You use these parameters to control how large such a data package typically is. If no entry is maintained, the data is transferred with a standard setting of 10,000 kbytes per data package. The memory requirement depends not only on the setting for data package size, but also on the width of the transfer structure, and the memory requirement of the  relevant extractor.
    2. Frequency
    With the specified frequency, you detemine after how many data IDocs an Info IDoc is sent, or how many data IDocs are described by an Info IDoc.
    The frequency is set to 1 by default. This means that an Info IDoc follows every data IDoc. Generally, choose a frequency of between 5 and 10, but not greater than 20.
    The larger the package size of a data IDoc, the lower you must set the frequency. In this way you ensure that, when loading data, you receive information on the current data load status at relatively short intervals.
    In the BW Monitor you can use each Info IDoc to see whether the loading process is running without errors. If this is the case for all the data IDocs in an Info IDoc, then the traffic light in the Monitor is green. One of the things the Info IDocs contain information on, is whether the current data IDocs have been loaded correctly.
    3. Size of a PSA partition
    Here, you can set the number of records at which a new partition is generated. This value is set to 1.000.000 records as standard.
    When you are integrating with Other SAP Components then
    SPRO ->SAP Customizing Implementation Guide->Integration with Other SAP Components->Data Transfer to the SAP Business Information Warehouse->General Settings->Maintain Control Parameters for the data transfer
    Maintain Control Parameters for Data Transfer
    Activities
    1. Source System
    Enter the logical system of your source client and assign the control parameters you selected to it.
    You can find further information on the source client in the source system by choosing the path Tools -> Administration -> Management -> Client Maintenance.
    2. Maximum Size of the Data Package
    When you transfer data into BW, the individual data records are sent in packages of variable size. You can use these parameters to control how large a typical data packet like this is.
    If no entry was maintained then the data is transferred with a default setting of 10,000 kBytes per data packet. The memory requirement not only depends on the settings of the data package, but also on the size of the transfer structure and the memory requirement of the relevant extractor.
    3. Maximum Number of Rows in a Data Package
    With large data packages, the memory requirement mainly depends on the number of data recrods that are transferred with this package. Using this parameter you control the maximum number of data records that the data package should contain.
    By default a maximum of 100,000 records are transferred per  data package.
    The maximum main memory requiremen per data package is approximately 2'Max. Rows'1000 Byte.
    4. Frequency
    The specified frequency determines the number of IDocs that an Info IDoc is to be sent to, or how many data IDocs an Info Idoc describes.
    Frequency 1 is set by default.. This means that an Info Idoc follows every data Idoc. In general, you should select a frequency between 5 and 10 but no higher than 20.
    The bigger the data IDoc packet, the lower the frequency setting should be. In this way, when you upload you can obtain information on the respective data loading in relatively short spans of time .
    With the help of every Info IDoc, you can check the BW monitor to see if there are any errors in the loading process. If there are none, then the traffic light in the monitor will be green. The Info IDocs contain information such as whether the respective data IDocs were uploaded correctly.
    5. Maximum number of parallel processes for the data transfer
    An entry in this field is only relevant from release 3.1I onwards.
    Enter a number larger than 0. The maximum number of parallel processes is set by default at 2. The ideal parameter selection depends on the configuration of the application server, which you use for transferring data.
    6. Background job target system
    Enter the name of the application server on which the extraction job is to be processed.
    To determine the name of the application server, choose Tools -> Administration -> Monitor -> System monitoring -> Server. The name of the application server is displayed in the column Computer.
    7. Maximum Number of Data Packages in a Delta Request
    With this parameter, you can restrict the number of data packages in a delta request or in the repetition of a delta request.
    Only use this restriction when you expect delta requests with a very high data volume, so that, despite sufficiently large data package sizes, more than 1000 data packages can result in a request.
    With an initial value or when the value is 0, there is no restriction. Only a value larger than 0 leads to a restriction in the number of data packages. For reasons of consistency, this number is not generally exactly adhered to. The actual restriction can, depending on how much the data is compressed in the qRFC queue , deviate from the given limit by up to 100.
    Thanks
    Chandran

  • Issues in Data Transfer Process

    Hello All,
    After creating transformation from Infosource to InfoCube, now i am trying to data transfer process.
    In DTP Type it displays "DTP for direct process", but i need DTP type as Standard(Can be scheduled).
    Its giving me an error as "Source does not support direct access"
    Could any one help me to solve this error.
    Thanks in advance
    Regards,
    Nithin

    Hi,
    You can only use the type DTP for Direct Access as the target of the data transfer process for a VirtualProvider.
    Check the below links
    http://help.sap.com/saphelp_nw04s/helpdata/en/42/fa50e40f501a77e10000000a422035/content.htm
    http://help.sap.com/saphelp_nw04s/helpdata/en/42/fb8ed8481e1a61e10000000a422035/frameset.htm
    Regards
    KP
    Edited by: prashanthk on Jan 19, 2011 5:15 PM

  • RE: Transformation and Data transfer process.

    Hi guys,
    Please some bosy help me out by providing the differences between Transformation and Data Transfer Process.
    thanks in adwance
    omkar

    Hi Omkar,
       Trnasformations providing the mapping between Sorce fields( datasource to  data target).  only map the structures..
    <b>Transformations:</b>----
    -->Trsnsformations are used to create mappings between two BI Objects and to
    transform data from BI Source(From where) to BI Target .
    -->You can create One-One Mappings between source and target in BI
    -->In transformations Source is : DataSource, InfoSource, DataStore object,
    InfoCube, InfoObject and InfoSet
    -->Target is: InfoSource, InfoObject, DataStore object and InfoCube.
    -->Transformations replaces the transfer and update rules.It's like creating transfer
    rules and update rules.Through these rules/mappings/transformations, the
    system is going to transform data from Source to Target.
      but DTP  means.. the data loading procedure will be  done with this step..
    <b>DTP :</b>
       DTP is used to transfer data from PSA to the infoprovider.
    The data transfer process can also be used to control data distribution from a BI system into any target outside of the BI system. For this purpose, a data transfer process with an open hub destination is used as the target.
           Since Deltas are now based on request from PSA ,you can have multiple datatargets pulling data with same selection criteria from same datasource(ECC) with INITS/DELTA,not possible earlier.
    http://help.sap.com/saphelp_nw2004s/helpdata/en/42/f98e07cc483255e10000000a1553f7/frameset.htm
    Creating DTP
    http://help.sap.com/saphelp_nw2004s/helpdata/en/42/fa50e40f501a77e10000000a422035/content.htm
    regards
    @jay

  • Init with out data transfer option is not enabled

    Hi Friends,
    I am loading data from the data soruce 0CO_OM_OPA_7 - (Internal order items) into BI. This datasoruce is delta enabled. Flow is designed in 3.5.  I checked the extractor RSA3, it shows 9 records and then i tried to load using init with data transfer, the load is not successful, it is in yellow for long time and gives the messages no record found. I tried with full load then load is successful. why init load is not successful?  Is there any setting i am missing here?
    Then I tried to go other option, run init without data transfer and then a full load, but I could not change the radio button to without data transfer option, it is defaultly taken init with data transfer and greyed out. How can i check init without transfer option?
    thanks in advance.
    Regards
    Sreekanth

    Hi,
    In the present case you need to delete the earlier initialization flag from infopackage. Once done then you can be able to view the init without data transfer option.
    So delete the flag in the menu bar --> Initialization option for source system
    in the popup select the init entry and use the trash icon to delete the same.
    Before doing that you can mark your earlier init load to Red and then perofrm this activity.
    Once done then you can execute init-without transfer wiht no issue.
    Once after this you can perform repair full load to load the data to your target.
    Hope this helps.
    Murali

  • Determining Data transfer rate through modem in java

    Hi,
    I want to write an application in java which will communicate with
    connected modem of the system and it will detect the data transfer rate.
    I want to know how much data is transferring(upload/download)through modem and in a specific time how much data is transferred.
    I will give some max upload/downloading limit for a specific time and if data transfer exceeds that limit,it will show message.
    e.g if i fix max upload/download data transfer limit by the modem is say 10GB/20GB for a specific time span say for 15 days.Then my program automatically will start when the Modem will be connected and keep a log of data transfer(upload/download)and if data transfer goes beyond limit then it will show message.Also i would be able to see how much data is transferred for any specific day.
    I want to know this type of application is possible in java.If yes then
    which API's i need to use.
    If this type of program is available in some site in other language then also i will be helpful.Pl give the links.
    byeeeeeeee
    Pradipto

    Hi,
    i want to do it in java only to explore the power of
    java.I agree with Abuse, Java is not designed for such applications. I'm not even sure if you can solve your problems with Java.

  • Advantages of using BAPI over LSMW for data transfer

    Hellow,
    Can anybody please give an input for advantages of using BAPIs in data transfer compare to LSMW. If we use BAPI for data transfer of master and transaction data how it is more usefull compare to LSMWs developed.
    Thanks in advance
    Raghav

    Hi Raghavendra,
    Refer the links..may help.....
    [http://www.*******************/search?q=BAPIandLSMW+comparision]
    [http://www.*******************/search?q=bapi]
    Regards,
    Mdi.Deeba

  • Help me find ghost files after botched data transfer

    I just bought a new MacBook. While setting up the OS upon first boot, I hooked up my old machine (which had a dead LCD, hence the new machine) for the data transfer. Well, after a solid hour+ of data transfer over firewire, there was an error, after which the old machine didn't seem to be a valid source of data transfer for the OS.
    So I boot up the new machine and none of my files appear to have transferred. Ok, I can transfer important things by hand, so it's no problem. I boot the old machine holding down T and it appears as a mounted volume, from which I copy my files.
    Here's the issue: that first, failed attempt to transfer files left "ghost" files somewhere eating up my HD space. Ie, if I sum up the size of all my files and folders in the / directory, they add up to around 60 Gb, which seems reasonable given all my music and such. But if I look at my main partition volume in Disk Utility, it claims I'm using a full on 179 Gb, which is totally unreasonable.
    So there's around 120 Gb of "ghost" usage laying around. How do I track it down?

    Log out and then into the newly created user account. To transfer them, choose Go to Folder from the FInder's Go menu, provide /Users/Shared/ as the path, and drag them there.
    (67061)

  • When transferring HR data from ECC to CRM via change pointers

    When transferring HR data from ECC to CRM via change pointers ,certain data is getting earsed in CRM
    paricularly the last name and first name of BUT000
    Do you have any idea why this could be happening
    Thanks in advance

    Hi Kittu,
    Change pointers. Change pointers are R/3 objects that mark changes to SAP master data. Change pointers are managed by mechanisms in a Shared Master Data (SMD) tool and are based on Change Document (CD) objects. CD objects record the changes occurring to master data at a field level. These changes are stored in tables CDHDR (header table) and CDPOS (detail table). ALE configuration provides a link between CD objects and change pointers. Internal mechanisms update tables BDCP and BDCPS, which host the change pointers. While CD objects are application-data-specific, the processing status of change pointers is message-type-specific. Also, the ALE change pointers are activated first at a general level and then at the message-type level.
    use this links kittu.
    http://help.sap.com/saphelp_nw04/helpdata/en/ab/27bde462848440ba70cf8eb348c86f/frameset.htm
    http://help.sap.com/saphelp_nw04s/helpdata/en/12/83e03c19758e71e10000000a114084/frameset.htm
    http://help.sap.com/saphelp_nw04/helpdata/en/0f/9d563cf19bcb43e10000000a11405a/frameset.htm
    http://help.sap.com/saphelp_nw04/helpdata/en/ab/27bde462848440ba70cf8eb348c86f/frameset.htm
    http://help.sap.com/saphelp_nw04s/helpdata/en/12/83e03c19758e71e10000000a114084/frameset.htm
    Creating a change pointer and subsequently triggering an IDOC
    thanks
    karthik

Maybe you are looking for

  • What are the best bluetooth headsets for running?

    With the new 3.0 software update, I want stereo bluetooth headsets to go running with. Any ideas on what the best brands are?

  • HR ABAP :Report to see charges incurred in all company codes

    HI All, I know i am asking to much but no other go because i dont have any functional details. I am very new to payroll .the requirment is to  create a report that allows the user to see charges incurred in all companies. The charges are selected by

  • Firewire audio interface power options

    I just bought a Presonus Firebox, which connects via Firewire 400 to my iMac. I use it to record audio for maybe 30 min per day. The box is powered by the Firewire, but gets a little warm after it's on for a while. But I don't want to keep unplugging

  • 8 seconds and song stops playing,

    hi, after 8 seconds of playing a song i imported (that works on itunes) the song wont play on the ipod, but if i foward to over 12 seconds the song plays ok, any ideas?

  • Leopard Won't start, I messed with permissions.

    Hi! Ok, i have a Macbook Pro, the hard disk failed and i taken it to repair, a new hard disk was installed and they put all my old disk information in the new one. I was happy. I started to work and realized that every time I wanted to save a file in