Hi Guys,
I have a question. There is a requirement about monitoring. Any documenation or links will be really appreciated.
My client needs me to use CCMS agents, alert monitoring for both ABAP and JAVA stacks, SNMP traps, sending SNMP traps, interface CCMS with third party monitoring tools. Mostly, the ,monitoring is done thru RZ20.
Anybody can point me in right direction or material.
Thanks
Venky
Hi,
Check these CCMS Weblogs. Really good ones...
/people/federico.babelis2/blog/2006/04/26/ccms-rule-based-monitors-configuration-guide-for-dummies
/people/aravindh.prasanna/blog/2005/12/23/configuring-scenario-specific-e-mail-alerts-in-xi-ccms-part--1
/people/aravindh.prasanna/blog/2006/02/20/configuring-scenario-specific-e-mail-alerts-in-xi-ccms-part-3
Feel free to revert back.
--Ragu
Similar Messages
-
SolMan 7.1 Alerts to SNMP traps
Hi all,
We will start the process of implement SolMan 7.1 and with this we will migrate all the alerting that we have in SolMan/CCMS 7.0 using CCMS autoreactions methods to the new Alert infrastructre provided in SolMan 7.1. It is my understanding that in SolMan 7.1 only emails are sent in case of alerts.
Has somebody configured SolMan 7.1 alerting with SNMP traps?
It is my undestanding that there is some kind of custom development required for this.
Please help me to understand the effort and any tips
Thanks,
ZarehHello Karthik,
You only need an ABAP developer, if you want to use a custom BADI.
But instead you can also use the "standard" SNMP configuration.
see HOW-To guide:
Description: see page 8
3.2 [SAP-Standard] usage
Starting with Solution Manager 7.10 SP06, a [SAP-Standard] BAdI implementation is shipped:
Configuration: see page 15
4 [SAP-STANDARD] SNMP CONFIGURATION
As of Solution Manager 7.10 SP06, a dedicated User Interface has been implemented to configure the SNMP Traps.
Make sure in transaction SICF that the service “mai_snmp_trap_config” is active.
4.1 User Interface
http://<SolutionManagerHost>:<port>/sap/bc/webdynpro/sap/mai_snmp_trap_config?sap-language=EN
Best regards -
Send solman alerts as SNMP traps?
We want to send solman alerts as SNMP traps to an external monitoring solution.
Can someone please provide info on how to do it?
ThanksHello Prasad,
a search for SNMP in the Online Documentation returns [Sending and Receiving Alerts Using SNMP Traps|http://help.sap.com/saphelp_nw70ehp1/helpdata/en/ff/0620fbf6a404479d48b9e24552f770/frameset.htm].
Regards, Michael -
Sending alerts as SNMP-Traps from Solman to Nagios
Hi!
we would like to set up the alerting structure for sending the alerts as SNMP-Traps from Solman to Nagios.
The questions:
1) Is such integration possible? If yes, how complexe?
2) What are the technical steps to perform in order to realize these steps?
3) What are the steps to perform on Nagios server?
Thank you very much!
regards
H. ThomassonHello Prasad,
a search for SNMP in the Online Documentation returns [Sending and Receiving Alerts Using SNMP Traps|http://help.sap.com/saphelp_nw70ehp1/helpdata/en/ff/0620fbf6a404479d48b9e24552f770/frameset.htm].
Regards, Michael -
Monitoring SNMP Traps from Windows Server
Hello All
im looking for a way to monitor an application that runs with os windows server 2003 and windows 2008 r2 and send its alarms as a snmp traps with system center operations maanger 2012 R2.
in the scom 2007 environment i could discover the servers as network device and recive traps and genrate alerts.
is there a way to edit the existing management pack to enable the windows server discovery as a network device
and enable traps with a microsoft oid to be resived ?
i understand that this is by desigin from
http://technet.microsoft.com/en-us/library/hh212935.aspx
or is there another option to create this monitor with scom 2012 R2?
Thank youHello Yan.
thank you for the replay i understand that this is by design,
what im looking for is a way to edit the management pack that discard those OID
or even a 3rd part solution to monitor windoes server snmp genrated alerts.
thank you -
Reporting Agent : Alert Monitor Preview - Short Dump
Hi All,
I have some questions related to Reporting Agent :
1.) When I am executing the Alert Monitor Preview, it ends with short dump.
2.) Where to do the settings for Email, Printing and Alert settings so as to send the notifications to the user using the different output options as mentioned above.
Please provide solutions.Hi Richa,
Chech in txn ST22 for your short dump to analyse the root cause of the error.
See this link for integration of BW Reporting with Alert Monitor.
https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/031faa90-0201-0010-23b3-a5b88e812d15
Cheers!
Amit -
Handling error in XI with CCMS and Alert Monitor
Hello,
I have configured the CCMS for handling XI error and use the auto-reaction method CCMS_Send_Alert_to_ALM for sending an alert when i have for exemple a mapping error.
The issues are :
1) When an alert is catched I can send an email or having a notification in the alertinbox but not the both.
2) When an alert is catched in the CCMS, this alert is in an active status and i can't receive a second alert if another error occurs in XI until i have completed manually the first alert. Is it possible to complet this alert automatically or having more than one alert active for the same node in the CCMS ?
Regards,
Vincent.Gopesh
The alerts are displayed to the recipient in one of the following programs:
.In the Universal Work List (UWL of the Enterprise Portal) as of SAP NetWeaver 04
· In an application that accesses the alerts using an API
· In the Alert Inbox. The Alert Inbox is an application based on Business Server Pages (BSP),which can be called using the transaction ALRTINBOX or the corresponding URL
(http:///sap/bc/bsp/sap/alertinbox).
There are also a number of external communication methods available. You can configure these in SAPconnect (transaction SCOT) and use them in addition to inform the recipient of an alert about the problem: Internet mail, SMS, and fax.
Just to cross check have you configured your alerts using the below urls:
https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/aeeda66b-0a01-0010-6884-876fac1c4a2d
https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/be79a16b-0a01-0010-51b8-9b6d1968338d
Regards,
---Satish -
SCOM 2012 unable to monitor SNMP traps
After installing SCOM 2012 I did not
get the SNMP Trap. I tried the solution
of the topics http://social.technet.microsoft.com/Forums/en-US/operationsmanagergeneral/thread/6826f6a6-bbc3-444b-9b18-288d7fedac3e Nothing
has helped.
Help please, why SCOM can
not take Traps?We had the an issue where device was sending SNMP v1 traps as per Wireshark but the device was discovered as a SNMP v2 device. We forced the device to be discovered as a SNMP v1 device and that worked.
To do so, after you add the device that needs to be discovered within the discovery rule, export the MP called Network Discovery Internal. Open this in notepad and browse to the IP address of your device that needs to be discovered. Change the value for
"AutoDetect" to v1 in case you want to discover his as a V1 DEVICE. Then you will be able to receive traps from the said device that got discovered.
<SeedSystem>
<SeedIPorName>10.100.x.x</SeedIPorName>
<Version>AUTODETECT</Version>
<SNMPPort>161</SNMPPort>
</SeedSystem>
Hope this helps.
Kapil Dham -
Cmd to Monitor SNMP traps 8.1
can anyone tell me the command to monitor or recevie the traps in 8.1
as the command for 10.3 is the below
java weblogic.diagnostics.snmp.cmdline.Manager SnmpTrapMonitor -p
do we have command for 8.1 wls please let me knowWe had the an issue where device was sending SNMP v1 traps as per Wireshark but the device was discovered as a SNMP v2 device. We forced the device to be discovered as a SNMP v1 device and that worked.
To do so, after you add the device that needs to be discovered within the discovery rule, export the MP called Network Discovery Internal. Open this in notepad and browse to the IP address of your device that needs to be discovered. Change the value for
"AutoDetect" to v1 in case you want to discover his as a V1 DEVICE. Then you will be able to receive traps from the said device that got discovered.
<SeedSystem>
<SeedIPorName>10.100.x.x</SeedIPorName>
<Version>AUTODETECT</Version>
<SNMPPort>161</SNMPPort>
</SeedSystem>
Hope this helps.
Kapil Dham -
SCOM 2012 SP1 - Show on event view all snmp trap (SNMP monitoring work)
Hello everybody,
Sorry for my english, I write normaly in french, but we have more result in english.
I have a problem with SCOM 2012. I try to catch all snmp traps sended by a 2960 CISCO switch on a EventView with a specific rule (Authoring->Rule->Collection Rules -> Event Based -> SNMP Trap (Event) based on the object target "Node")
I creat a specific management pack juste for the rule and the views.
SNMP Monitoring - CISOC 2960 => It's OK, I can have the processor state, utilization, etc ...
SNMP Monitoring Ubuntu computer => It's OK, I can have all the state I want.
SNMP Traps => The switch or the computer send traps over the network, and I can see in wireshark, the server receive the traps
SNMP Service (Windows service) => Disabled
SNMP trap (Windows service) => Disabled
Health Service (Windows service) => Enabled
Port 162 UDP => Open and listenning by the MonitoringHost.exe
Firewall rules => Everythinks is OK
SNMP Trap send version is => 2c
SNMP Monitoring device version is => 2c
I try too many of solution on different web site like :
http://scom-2012.blogspot.ch/2012/07/setting-up-snmp-monitoring-in-scom-2012.html
http://social.technet.microsoft.com/Forums/systemcenter/en-US/731661b9-10a1-4d3f-ba83-8e84d25ab760/event-collection-for-network-devices-scom-2012
http://social.technet.microsoft.com/Forums/systemcenter/en-US/a15bce49-fb62-4fd4-93cf-f87c3b734d58/snmp-trap-based-monitoring?forum=operationsmanagergeneral
http://social.technet.microsoft.com/Forums/systemcenter/en-US/41f5b6ef-c8b9-461d-bdcb-81fde5a89f50/scom-2012-unable-to-monitor-snmp-traps?forum=operationsmanagergeneral
http://social.technet.microsoft.com/Forums/systemcenter/en-US/4051fbd1-06f1-49e0-9ad4-4cbe4d2d7d4d/discover-windows-computer-as-network-device-w-snmp?forum=operationsmanagerauthoring
http://technet.microsoft.com/en-us/library/hh563870.aspx
http://social.technet.microsoft.com/Forums/en-US/cad1d3f9-594f-4f06-a5aa-660ccc2e9192/snmp-trap-based-monitoring-in-scom-2012-sp1?forum=operationsmanagerauthoring
http://social.technet.microsoft.com/Forums/en-US/41f5b6ef-c8b9-461d-bdcb-81fde5a89f50/scom-2012-unable-to-monitor-snmp-traps?forum=operationsmanagergeneral
http://social.technet.microsoft.com/Forums/en-US/e05a1c8f-7280-4f80-86cf-aabb4269bb87/scom-2012-customizing-snmp-trap-event-data?forum=operationsmanagergeneral
http://social.technet.microsoft.com/Forums/en-US/6826f6a6-bbc3-444b-9b18-288d7fedac3e/scom-unable-to-monitor-snmp-traps?forum=operationsmanagergeneral
http://social.technet.microsoft.com/Forums/en-US/7cd1571a-d292-4efc-9921-5a068f6f1691/scom-2012-sp1-ur2-snmp-monitoring?forum=operationsmanagermgmtpacks
Do you know a workaround? Or a different way to catch all the traps from a network device and show them (traps) on a event views.
Thank you in advance.
KimBaxZ
Computer expert system technologyHello Yan Li,
I read your link, and I found this :
The network devices must be discovered and registered as ICMPSNMP devices.
And when I make the dicovery the first time, ICMP doesn't work, so I put only SNMP. This morning I tried with ICMP and SNMP, but the same problem come to me. And I found the rootcause of the problem with this post : http://www.code4ward.net/main/Blog/tabid/70/EntryId/105/Troubleshooting-Network-Discovery-in-SCOM-2012.aspx
I allowed the SNMP service, ping, and Health Service, just after I try a second time to dicover my device and it's work (ICMP and SNMP).
I recreat all my management pack and the rule. And now it's work! Thank you very much for your help!!
Have a nice day
Best regards
KimBAxZ
Computer expert system technology -
Hi
Is there any way to send the alert with snmp trap instead of SMTP message?
Regards
GregIs there any way to send the alert with snmp trap instead of SMTP message?
Unfortunately today the SNMP support on the S-series is fairly limited - and traps are one of the things which is missing.
The good news is that we're fixing this, and the next version of AsyncOS for the S-series will have much better SNMP support, including traps.
So for the moment you're stuck with using either email messages or Syslog - but you shouldn't have to wait too long for SNMP traps! -
SCOM receiving SNMP traps from HP IMC
Hi all,
I've been tasked with creating SCOM alerts from SNMP traps which are forwarded from HP IMC. Each SNMP trap will arrive at SCOM from a single source (IMC server) but each will contain different information. Can someone suggest the best way for me to generate
individual alerts from this? I'd also appreciate any comments on alternative ways to do this (apart from simply using both systems separately!).
The environment is SCOM 2007 R2 on a 2003 R2 server.
Thanks in advance for any suggestions.Hi
This comes up on the forums quite often so here are a summary of some of the best articles I’ve found on the net:
Configuring using the GUI:
The System Center Central team have a great series –
Part I,
Part II,
Part III, and
Part IV
David Allen has a good walkthrough here about creating
SNMP Probe based monitors.
Issues with using the GUI to create monitors with numeric expressions – see Raphael Burri’s
blog
SNMPVarBinds and the Alert Description Field –
http://blogs.msdn.com/b/rslaten/archive/2007/10/31/snmpvarbinds-and-the-alert-description-field-in-opsmgr-2007.aspx
oring Console:
Kris Bash at Operating Quadrant has some great articles on SNMP monitoring.
The only thing to be careful of before investing too much time in customisation for network devices on SCOM 2007 R2 is that when you move to SCOM 2012, you might well need to redo them as network monitoring has changed.
http://blogs.technet.com/b/momteam/archive/2011/10/24/migrating-operations-manager-2007-network-monitoring.aspx
Cheers
Graham
Regards Graham New System Center 2012 Blog! -
http://www.systemcentersolutions.co.uk
View OpsMgr tips and tricks at
http://systemcentersolutions.wordpress.com/ -
No SNMP traps from sun x4150 ILOM server
Hi all,
I have set up the ILOM alerts with SNMP traps (v2c,public) according to the ILOM user guide and pressed the "send test alerts". Nothing shows up in the SNMP trap monitor (using MG-SOFT software). When I add another alert of IPMI pet type (same destination ip as of SNMP trap alert) I see events in the trap monitor. It looks like the ILOM does not generate SNMP traps but only IPMI traps.
In the ILOM user guide there is an explicit example of traps sent from the ILOM (in addition to the fact that the ILOM features include SNMP traps AS WELL as IPMI) so it seems this is possible...
my ILOM version is
SP Firmware Version 2.0.2.6
Does anyone have any idea of any step I have missed ?
Thanks in advance.
LiorOnce the Network Device (Linux server in this case) is discovered you will still need a rule that targets that class and accepts incoming SNMP Traps for that OID, or All OIDs if you prefer. I found 2 links that may be of help, the first is just a basic
overview of the SNMP listener in SCOM 2012 as it has changed from the OS Listener in 2007 to a dedicated one.
http://systemcentertech.com/2012/05/17/scom-2012-built-in-snmp-trap-listener/
The second link covers SNMP setup, but starting at Step 7 there is a great how-to on creating your own SNMP rule which will be needed to collect your traps.
http://scom-2012.blogspot.com/2012/07/setting-up-snmp-monitoring-in-scom-2012.html
www.Practice2Perfect.com -
Hi Experts,
I am doing SAP CCMS agent installation to monitor a non-SAP system which will be monitored by a Central monitoring system.
I have followed all the steps as:
http://help.sap.com/saphelp_nw04/helpdata/en/a8/adf7409b9d8531e10000000a1550b0/frameset.htm
http://help.sap.com/saphelp_nw04/helpdata/en/e2/eff640fa4b8631e10000000a1550b0/frameset.htm
1. communication user CSMREG in Central monitoring system.
Created the CSMCONF start file for CCMS agents in monitoring system.
2. CCMAGENT.SAR , SAPOSCOL.SAR , INSTALL_WIN.SAR
And done the configurations required in the monitored system.
3. Register the CCMS agent with CEN and start the agent. By following this step:
<hostname>\saploc\prfclog\sapccmsr.exe -R*
while registering the CCMS agent ,
I ma getting this...
This CCMS agent program sapccmsr is able to actively report alert data into the monitoring system[CEN], which is the central monitoring system.
to enable this feature, you have to setup the user CSMREG in [CEN].
After entering the RFC logon info for the user,
client:001
user:CSMREG
language:EN
host name:
load balancing:n
system number:01
router sting :optionla
trace lavel:0
password for CSMREG user:********
Its showing this error:
ERROR: RFC error during logon: 105 DESTINATION_NOT_EXIST
How to solve this?
Do I have to do any RFC configuration in the Central monitoring system(as I want to monitor a non-SAP system)?
urgently required.
Any help will be appreaciated.
Regards
ManishaHi Manisha,
Yes you will have to create a RFC and a suitable RFC user in the Central Monitoring System (CEN) via txn RZ21 to monitor these remote systems.
Please follow this link:
http://help.sap.com/saphelp_nw04/helpdata/en/a8/adf7409b9d8531e10000000a1550b0/frameset.htm
Please award suitably if helpful.
Regards, Dibya -
SNMP Trap Translation Wrong For Hebrew Language
SR 3-4956842281
sev 2
Cus ISRAEL CREDIT CARDS LTD
=====================
Customer is using OMS 10.2.0.5 on linux server.
They have created an user defined metric on DB cluster instance with alert message written in hebrew.
The OMS console showed the alert in hebrew as expected.
However when they send this alert with snmp trap notification to a second system (HP openview for windows) then the message appeared not cleared (with question marks). This second system get messages in hebrew from other systems without any problems.
+Does setting LANG variable at OMS level will impact this
+Any tracing which can help to find the cause of the issueClosing as issue found at HP openview parameter settings
Maybe you are looking for
-
I installed a Mac Mini Server in my media room. Connected it on my Ethernet, where i also have two other mac mini's a Mac Book Pro throughout the house. They all do "see" and "talk" to each other, and share files, like they are supposed to do. The on
-
Rotate -90 degrees to play in a vertical monitor...
Hi all! Is it possible to Rotate -90 degrees image to play in a vertical monitor... I have all the sequence edited with Motion / FCP / PSPs... now the client needs a dvd to play in a vertical monitor. Is it possible to rotate in DVDsp (at the burn ti
-
Any standard infotypes for capturing project details
Mates client has few departments like finance,hr,it etc and in which project/operation is one of them.They have employee working in different projects say A,B,C..and they are deployed in different places..my doubt is how do we treat this project? co
-
What is wrong in this code .... !
Hi I used the code below to raed a histogram image stored in an two dim. array to detmine the peaks of the histogram or in other words (the tallest rows in the array) but I faced a wrong results. Why ? I couldnt figure out why . Help me plz . Thanks
-
Appmenu-qt causeing trouble since KDE 4.9.5
Hey guys, I just updated to KDE 4.9.5 just to discover that having appmenu-qt installed (I don't use it) makes menu bars go to nirvana. I simply uninstalled the package and the menu bars appeared again. Someone else experiencing the same issue? The p