CEWB:Inspection Plan upload
Hi! Experts,
We are having a requirement wherein we need to upload mass number of Inspection Plans.
Currently, we are thinking of using LSMW.
Can anybody also explore on the possibilities of using Engineering Workbench tool.
(i)Steps involved in CEWB--- (T-code wise)
(ii)Feasibility as compared to LSMW/BDC.
Thanks in advance,
Rishi
Hi,
Find information on CEWB here:
http://help.sap.com/saphelp_erp2005/helpdata/en/73/517c3545413671e10000009b38f889/frameset.htm
Regards
R.Brahmankar
Similar Messages
-
How to create inspection plan in mass for material
Dear Guru,
How to create inpection plan for material in MASS, usually we will create inspection plan in QP01 but in mass for more than one material how to maintaain? Please help
Regards
Karthik.Hi raja
refer following lonks
QM- LSMW FOR INSPECTION PLAN
Re: CEWB:Inspection Plan upload
bapi for qm inspection plan
Regards
Sujit -
Long text problem while uploading Inspection plan through BDC.
Hi,
I am facing some problem while uploading the inspection plan. There are few MICs for which we are having long text, while uploading the inspection plan through BDC - some other long text is getting copied into the MIC's long text. After checking I came to know that in function module, read_text - some text which is stored in ABAP memory is getting copied into the inspection plan.
I am working in SAP release 4.7. I have checked with SAP notes: 97419, but it is also not satisfying.
Waiting for quick solution.
Thanks in advance.
FahiéHi a®s,
Thanks a lot for your kind reply.
My requirement is I want to maintain long text for few MICs (which are not having long texts at MIC level) in inspection plan (QP01).
When I am trying to manually assign the MIC's to inspection plan (QP01), long text is copied whereas I am not clicking the long text icon in (QP01). Long text is not maintained in MIC level, still some long text is copied to this MIC. This was also happening while uploading the inspection plan thro' BDC.
I believe what you have mentioned about function module SAVE_TEXT cannot be used here since long text is already copied before we pass the long text. Also if we pass some long text, still apart from the long text what we have passed there is some other long text copied (extra long text).
Waiting for quick solution.
Thanks in advance.
Fahié -
Error in LSMW in Uploading Inspection Plan in QP01
Hi All,
I am facing problem when executing LSMW, I am Uploading Inspection Plan in QP01 transaction using Direct Input methos. The problem is on 13th step :Error that I get is 'No profile with entry tool for task list / / / in session INSPECTION_OBJ', here INSPECTION_OBJ is the name of the session. I have given the constant value of field profile (BIPKO-PROFIDNETZ) in mapping step and also activated check box 'entry tool' under profile to remove this error. But in that case i can pass only the header data while processing the session and control does not get into Operation and characteristic screen.
Can anyone pls help me..
Thanks in advance...You might need to redo the recording all over again, BDC has plentty of scenario for screen selection to go wrong, so can't really tell what cause your problem based on your desc. I have been stop using BDC to uplaod material since 5 years ago, I always use Direct input in LSMW and it works much better. I recomend you try the Direct input method instead of BDC if still getting problem.
-
Lsmw by bapi for qm to upload inspection plan qp01
I want to upload Inspection plan by Transaction qp01
<Edited by Moderator - Bhavesh Kantilal. Removed all Capitals post. User has been warned and request to move this thread to the appropriate forum has been raised.>
Edited by: Bhavesh Kantilal on Dec 20, 2008 1:50 AMPost it here:
ABAP Connectivity
Also, Please do not use all CAPS.
It is understood as shouting at people.
Regards,
Ravi -
Best Way to upload Inspection plan
Dear all,
Which is best way to upload inspection plan.
Thanx & Regards,
Harish Parab.Hi Harish,
The Best Method is BDC as posted by others in the thread.
Please also go through the below thread for approach for Master Data Migration as discussed earlier.
[Link|Extension of Quality/Inspection Plan;
Thanks,
RKM. -
Error while uploading Inspection plan
Dear Friends,
I am creating inspection plans using BDC. The MIChas 2 versions. When i am using version 1, the inspection plan is created. Whereas when i am using MIC version 2 i am getting error "error occured while checking type group".Kindly let me know how do i resolve this.
Regards
VivekHi,
Thanks for the reply. when i am trying to create a inspection plan in other plant, we have 4-5 sampling procesures to select from. But for this perticular plant where we are having problem, its showing only one. How do i get more options?How do i extend a sampling procedure to a new plant.
Vivek
Edited by: vivek mankad on Feb 23, 2010 7:57 AM -
Errors while creating Inspection plan using BAPI_INSPECTIONPLAN_CREATE
Hi All,
I am writing an upload tool for inspection plans. In this program I use bapi: BAPI_INSPECTIONPLAN_CREATE.
I made an extraction of a excisting inspection plan with SXDA_TOOLS which uses the same bapi and filled the bapi structures with the similar data. Now I am getting strange messeges in the return structure as below.
1. Material is not maintained for plant NNNN. But the material is mainained for that plant.
2. Consistency check not successful when creating operation
3. Inspection characteristic cannot be uniquely assigned to one operation
Let me know your suggestions
Thanks,
SabuHi All,
Have any one used this BAPI, BAPI_INSPECTIONPLAN_CREATE to create Inspection Plan ?
Can you help me on above errors?
Thanks in advance,
Sabu -
QM Inspection Plans migration - How to migrate deleted plans.
Hello All,
I'm currently working on a migration project from 4.7 to 6.0.
Our customer wants to migrate all QM inspection plans, including those are marked as deleted (PLKO-LOEKZ = 'X').
I'm using BAPI_INSPECTIONPLAN_CREATE. The BAPI works fine when the inspection plan which is being loaded is not marked as deleted. But when I try to upload another one which is mark as deleted (BAPI1191_TSK_C-DEL_IND = 'X'), I get the following error from BAPIRETURN: "The object does not exist for scheduled deletion time" (Message class CPCC_DT, number 214).
Does anybody knows if it is possible to load inspection plans marked as deleted using this BAPI?C N,
The principal Idea is to migrate either
- the original amounts, the installment plan and last the latest payments (you migrate payment history)
- or to migrate the still open amount as one or more open items and subsequently an installment based on that amount.
Kind regards,
Fritz -
I am creating the Inspection Plans by using the BAPI_INSPECTIONPLAN_CREATE.
I got the below errors please provide the solution for this.
1)The valid-from data has been set from today's date
2)Enter another operation number
3)Enter another operation numberhi rk.....
First One is just a Information message and last two is because of invalid activity or operation id entered wrongly...
Also u can have a look at my code for uploading inspection plan using bapi....
[Click here to view code...|https://wiki.sdn.sap.com/wiki/display/Snippets/ABAPProgramtouploadQMInspectionPlanUsingBAPI]
Also take a look at the template and sample data file attached at the given link...
Regards
KArthik D -
Hi,
I am trying to upload inspection plan master data in QP01 tcode.
I was given a program in BDC which does the same. but the problem with this program is that....its not updating inspection characteristics after 13th record. line is not getting incremented. Below is my code .plz help
page_count is initialized to zero.
IF WRK-NUMB_LOOP > 1.
PERFORM F_DYNPRO USING:
' ' TRQPAS_SEL_FLG ' '.
ENDIF.
(This below part is branced out when 13 records are processed....otherwise it skips this and does the normal process)
IF WRK-NUMB_LOOP > 13.
PAGE_COUNT = INCR + ( WRK-NUMB_LOOP * 10 ).
INCR = PAGE_COUNT.
MOVE 2 TO WRK-NUMB_LOOP.
PERFORM F_DYNPRO USING:
'X' 'SAPLQPAA' '0150',
' ' 'RQPAS-AB_MKNR' INCR,
'X' 'SAPLQPAA' '0150'.
ENDIF.
TRQPAS_SEL_FLG+14(2) = WRK-NUMB_LOOP.
TPLMKB_VERWMERKM+16(2) = WRK-NUMB_LOOP.
TRQPAS_QUANTITAT+16(2) = WRK-NUMB_LOOP.
TRQPAS_QUALITAT+15(2) = WRK-NUMB_LOOP.
PERFORM F_DYNPRO USING:
' ' TRQPAS_SEL_FLG 'X',
' ' TPLMKB_VERWMERKM INTQPMK-MKMNR.
(few more performs are here)(when branced out for 13 records...its not performing the below dynpro performs..)
IF PAGE_COUNT > 0.
SUBTRACT 1 FROM WRK-NUMB_LOOP. "TLDD
TRQPAS_SEL_FLG+14(2) = WRK-NUMB_LOOP.
ENDIF.
CLEAR PAGE_COUNT.
wrk-numb_loop increments after one record is completely processed.
After getting to 13th line my program is not reading the perform dynpro.....code ...
any help is appreciated.There is no such direct mapping table, cross-table or Function module that describes how the Qualitative/Quantative fields are populated.
SAP follows certain mapping to populate the values for these fields this can be cheked in SCN for Qualitative and Quantitative control indicators mapping.
Secondly to update these indicators in Inspection plan load, you can use the STEUERKZ field value from QPMK table.
This field is concatenation of the 28 control indicators (QMKST structure for Quali/Quantitative fields).
So while uploading the data for Inspection plan, Inspection chracteristics are updated in system first where STEUERKZ can be updated.
Vice versa to know what each indicator value signifies in
the field QPMK-STEUERKZ, we can use the function module QSS0_QMKST_RQMST.
Regards,
Nidhi -
LSMW for Quality Inspection Plan
Dear All,
I am in process of uploading Quality Inspection Plans through process of LSMW with standard object 0240 (Inspection Plans) with batch input method. With this when I am trying to create Batch Input Session, system is throwing me error as 'Characteristics is not yet created' (Message Number - QS 320). I have maintained all the relevant master data before going to upload Q Inspection Plan.
Could any one pl. throw light on this issue?
Regards,
PrashantDepending on what control indicator key for master inspection characteristics have you implemented in the operations within the plan, the system checks if the characteristics are completely maintained.
This has nothing to do with LSMW, it's just a normal message,.....what I find estrange is that the message you're saying is a warning message not an ERROR message. -
Hi Sapiens,
I am a requirement to upload the Quality Management data through LSMW.
1) Quality Info Recrod
2) Inspection Plan
For the first one, I could able to create Project in LSMW and successfully do for over 200 customers.
I am saying problem in creating and uploading the Inspection Plan data.
I created one inspection plan with a material in QP01 (Tcode), and assigned one customer in "Material Assignment".
We have only hand full of materials (6-10 max) with MICs (10 - 15 max). So I using the same Inspection plan for material and I want to assign all the customer in Inspection plan at "Material Assignment". But at "Run Batch Input Record" in LSMW, it is failing. due to the below errors.
1) Field MAPL-PLNAL(2) is not an input field
2) Field MAPL-MATNR(2) is not an input field
3) Field MAPL-WERKS(2) is not an input field
I understand that these fields are repeating, as these fields are required in "Material Assignment" tab, where I will mention Counter, Matl, Plant and Customer. but it is saying these fields are not for input. If I dont use these fields in Field mapping then it will throw an error during actual recording.
So, I need some inputs on it and all of your suggestions will be valuable.
Awaiting of your reply on this soon.
thanks,
MukeshHi Mukesh,
I would suggest to go for BAPI instead of LSMW for the inspection plans, if possible.
Regards,
Rahul -
Hello friends,
We have writting one BDC for creating and changing the inspection plan, In this, the plan creation is successfully done.
when we go for change, the system throws the error "task list is invalid create task list".
once we log out the session and login again that uploaded inspection plan is shown with out any error.
we can't address this issue? Kindly help us to fix this....
regards,
sathesHi,
Please clarify that uploaded inspection plan is created one or changed one. To execute the changes for inspection plan the criteria in task list might be inavalid. Hence triggering the error. Please create new task list group in IA05. Thanking you. -
QP01 - To Create a Inspection Plan
Hi Associates and Consultants,
Have any one worked on T-Code QP01 to create a Inspection Plan Using BDC's or BAPI's.
If so please try to ping me.
Regards,
sg*& Report ZQMB_QP01_INSP_PLAN_NEW
REPORT ZQMB_QP01_INSP_PLAN_NEW
NO STANDARD PAGE HEADING LINE-SIZE 255 MESSAGE-ID ZQMB_INSP_PLAN_NEW.
D A T A D E C L A R A T I O N *
TYPES: BEGIN OF TY_TABDATA,
MATNR TYPE RC27M-MATNR, "Material No
WERKS TYPE RC27M-WERKS, "Plant
PLNNR TYPE RC271-PLNNR, "Key for Task List Group
AENNR TYPE RC271-AENNR, "Change Number
KTEXT TYPE PLKOD-KTEXT, "Task list description
VERWE TYPE PLKOD-VERWE, "Task list usage
STATU TYPE PLKOD-STATU, "Status
SLWBEZ TYPE PLKOD-SLWBEZ, "Identification for the Inspection Point Field Combination
QPRZIEHVER TYPE PLKOD-QPRZIEHVER, "Sample-Drawing Procedure
END OF TY_TABDATA.
TYPES: BEGIN OF TY_TBCTRL1,
MATNR TYPE RC27M-MATNR, "Material No
WERKS TYPE RC27M-WERKS, "Plant
PLNNR TYPE RC271-PLNNR, "Key for Task List Group
AENNR TYPE RC271-AENNR, "Change Number
ARBPL TYPE PLPOD-ARBPL, "Work center
STEUS TYPE PLPOD-STEUS, "Control key
LTXA1 TYPE PLPOD-LTXA1, "Operation short text
END OF TY_TBCTRL1.
TYPES: BEGIN OF TY_TBCTRL2,
MATNR TYPE RC27M-MATNR, "Material No
WERKS TYPE RC27M-WERKS, "Plant
PLNNR TYPE RC271-PLNNR, "Key for Task List Group
AENNR TYPE RC271-AENNR, "Change Number
ARBPL TYPE PLPOD-ARBPL, "Work center
STEUS TYPE PLPOD-STEUS, "Control key
VERWMERKM TYPE PLMKB-VERWMERKM, "Master Inspection Characteristics
PMETHODE TYPE PLMKB-PMETHODE, "Inspection Method
PMTVERSION TYPE PLMKB-PMTVERSION, "Version Number of the Inspection Method
STICHPRVER TYPE PLMKB-STICHPRVER, "Sampling Procedure in Inspection Characteristic
PRUEFEINH(7)," TYPE PLMKB-PRUEFEINH, " Value
PROBEMGEH(3)," TYPE PLMKB-PROBEMGEH, "Unit
STELLEN(3), "TYPE PLMKB-STELLEN, "Number of Places to the Right of a Decimal Point (Accuracy)
MASSEINHSW TYPE RQPAS-MASSEINHSW, "Measurement Unit in Which Quantitative Data Is Maintained
SOLLWERT TYPE QFLTP-SOLLWERT, "Target Value for a Quantitative Characteristic
TOLERANZUN TYPE QFLTP-TOLERANZUN, "Lower Specification Limit
TOLERANZOB TYPE QFLTP-TOLERANZOB, "Upper Specification Limit
DUMMY10 TYPE PLMKB-DUMMY10, "Info Field1
DUMMY20 TYPE PLMKB-DUMMY20, "Info Field2
DUMMY40 TYPE PLMKB-DUMMY40, "Info Field3
END OF TY_TBCTRL2.
TYPES: BEGIN OF TY_CHECK,
MATNR TYPE RC27M-MATNR, "Material No
WERKS TYPE RC27M-WERKS, "Plant
PLNNR TYPE RC271-PLNNR, "Key for Task List Group
AENNR TYPE RC271-AENNR, "Change Number
END OF TY_CHECK.
Declaration of the Internal Table & Work Area.
DATA: ITST_TABDATA TYPE SORTED TABLE OF TY_TABDATA WITH
UNIQUE KEY MATNR WERKS PLNNR, " AENNR,
" Internal table for Non-Table Control Records
WA_TABDATA TYPE TY_TABDATA,
ITST_TABCTRL1 TYPE TABLE OF TY_TBCTRL1 , " Internal table for the First Screen with Table Control
WA_TABCTRL1 TYPE TY_TBCTRL1,
ITST_TABCTRL2 TYPE TABLE OF TY_TBCTRL2, " Internal table for the Second Screen with Table Control
WA_TABCTRL2 TYPE TY_TBCTRL2,
ITST_CHECK TYPE TABLE OF TY_CHECK, " Internal table to check if record already exists
WA_CHECK TYPE TY_CHECK.
Constants
CONSTANTS: C_QP01 TYPE CHAR4 VALUE 'QP01', " Transaction Name
C_A TYPE CHAR1 VALUE 'A', " Mode
C_S TYPE CHAR1 VALUE 'S'. " Status
Global data Declaration
DATA: GV_YEAR(4) TYPE C, " Year part for Date
GV_MNTH(2) TYPE C, " Month part for Date
GV_DATE(2) TYPE C, " Day part for Date
GV_DATUM(10) TYPE C, " Concatenated Date in dd.mm.yyyy Format
GV_ANS TYPE C, " Answer to Continue
GV_FLAG_NEW(1) TYPE N VALUE 0. " Flag to set if Inspection Plan exists.
Declaration of the Internal Table with Header Line comprising of the uploaded data.
DATA: BEGIN OF IT_FILE_UPLOAD OCCURS 0.
INCLUDE STRUCTURE ALSMEX_TABLINE. " Rows for Table with Excel Data
DATA: END OF IT_FILE_UPLOAD.
Batch Input Data for a single Transaction.
Message of Call Transaction.
DATA: ITST_BDCDATA LIKE BDCDATA OCCURS 0 WITH HEADER LINE, " BDC Table
ITST_MSGTAB LIKE BDCMSGCOLL OCCURS 0 WITH HEADER LINE. " BDC Messages
S E L E C T I O N - S C R E E N *
SELECTION-SCREEN: BEGIN OF BLOCK B1 WITH FRAME TITLE TEXT-001,
BEGIN OF BLOCK B2 WITH FRAME TITLE TEXT-004.
PARAMETERS: P_FNAME LIKE RLGRAP-FILENAME OBLIGATORY.
SELECTION-SCREEN: END OF BLOCK B2,
END OF BLOCK B1.
E V E N T : AT S E L E C T I O N - S C R E E N *
AT SELECTION-SCREEN ON VALUE-REQUEST FOR P_FNAME.
CALL FUNCTION 'KD_GET_FILENAME_ON_F4'
EXPORTING
STATIC = 'X'
CHANGING
FILE_NAME = P_FNAME.
E V E N T : S T A R T - O F - S E L E C T I O N *
START-OF-SELECTION.
Upload Excel file into Internal Table.
PERFORM UPLOAD_EXCEL_FILE. " To Upload the Excel File
IF NOT IT_FILE_UPLOAD IS INITIAL.
Confirm whether you want to proceed with the Upload.
PERFORM CONFIRM_UPLOAD.
IF GV_ANS EQ '1'.
Organize the uploaded data into another Internal Table.
PERFORM ORGANIZE_UPLOADED_DATA.
Validate if already some Inspection Plan exists for that Material Plant
IF ITST_TABDATA[] IS NOT INITIAL.
SELECT MATNR
WERKS
PLNNR
FROM MAPL
INTO TABLE ITST_CHECK
FOR ALL ENTRIES IN ITST_TABDATA
WHERE MATNR = ITST_TABDATA-MATNR AND WERKS = ITST_TABDATA-WERKS AND
PLNNR = ITST_TABDATA-PLNNR
AND PLNTY = 'Q' AND LOEKZ <> 'X'.
ENDIF.
LOOP AT ITST_CHECK INTO WA_CHECK .
LOOP AT ITST_TABDATA INTO WA_TABDATA WHERE MATNR = WA_CHECK-MATNR
AND WERKS = WA_CHECK-WERKS AND PLNNR = WA_CHECK-PLNNR.
AND AENNR = WA_CHECK-AENNR.
IF SY-SUBRC = 0. " If exists SET FLAG = 1.
GV_FLAG_NEW = 1.
DELETE ITST_TABDATA WHERE MATNR = WA_CHECK-MATNR AND WERKS = WA_CHECK-WERKS
AND PLNNR = WA_CHECK-PLNNR.
AND AENNR = WA_CHECK-AENNR.
DELETE ITST_TABCTRL1 WHERE MATNR = WA_CHECK-MATNR AND WERKS = WA_CHECK-WERKS
AND PLNNR = WA_CHECK-PLNNR.
AND AENNR = WA_CHECK-AENNR.
DELETE ITST_TABCTRL2 WHERE MATNR = WA_CHECK-MATNR AND WERKS = WA_CHECK-WERKS
AND PLNNR = WA_CHECK-PLNNR.
AND AENNR = WA_CHECK-AENNR.
ENDIF.
ENDLOOP.
ENDLOOP.
Kick-start BDC Operation
PERFORM F_START_BDC. " If answer is YES, then start BDC Operations
ENDIF.
ELSE.
LEAVE PROGRAM. " If answer is NO or CANCEL then leave program
ENDIF.
*& Form F_START_BDC
text
--> p1 text
<-- p2 text
FORM F_START_BDC .
DATA : LV_FNAM(20) TYPE C, " Concatenated field name
LV_IDX1(3) TYPE N VALUE 1, " Index For Table Control 1
LV_IDX2(3) TYPE N VALUE 1, " Index For Table Control 2
LV_GOTO(4) TYPE N , " Index for GoTo Line No incase of Page Down
LV_PG(3) TYPE N VALUE 1, " Index for Page No
LV_IDX(3) TYPE N VALUE 1.
IF ITST_TABDATA[] IS INITIAL.
MESSAGE E000. " If Inspection Plan exists for all items in file, show error message
ENDIF.
LOOP AT ITST_TABDATA INTO WA_TABDATA.
LV_IDX2 = '1'.
CLEAR ITST_BDCDATA.
REFRESH ITST_BDCDATA.
GV_YEAR = SY-DATUM+0(4).
GV_MNTH = SY-DATUM+4(2).
GV_DATE = SY-DATUM+6(2).
CONCATENATE GV_DATE '.' GV_MNTH '.' GV_YEAR INTO GV_DATUM.
PERFORM BDC_DYNPRO USING 'SAPLCPDI' '8010'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'RC27M-MATNR'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'/00'.
PERFORM BDC_FIELD USING 'RC27M-MATNR'
WA_TABDATA-MATNR. " 'kiz0006c'
PERFORM BDC_FIELD USING 'RC27M-WERKS'
WA_TABDATA-WERKS. " 'B001'
PERFORM BDC_FIELD USING 'RC271-PLNNR'
WA_TABDATA-PLNNR. " 60000000-99999999
PERFORM BDC_FIELD USING 'RC271-STTAG'
GV_DATUM. " '16.01.2008'
PERFORM BDC_FIELD USING 'RC271-AENNR'
WA_TABDATA-AENNR. " CHANGE NUMBER
IF GV_FLAG_NEW = 1. " If Exists then diff screen for clicking NEW ENTRIES tab
PERFORM BDC_DYNPRO USING 'SAPLCPDI' '1200'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'RC27X-ENTRY_ACT'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=ANLG'.
PERFORM BDC_FIELD USING 'RC27X-ENTRY_ACT'
'1'.
PERFORM BDC_DYNPRO USING 'SAPLCPDA' '1200'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'/00'.
ELSE.
PERFORM BDC_DYNPRO USING 'SAPLCPDA' '1200'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'/00'.
ENDIF.
IF WA_TABDATA-KTEXT <> SPACE.
PERFORM BDC_FIELD USING 'PLKOD-KTEXT'
WA_TABDATA-KTEXT. " 'ZOLMITRIPTAN STAGE C1111'
ENDIF.
PERFORM BDC_FIELD USING 'PLKOD-VERWE'
WA_TABDATA-VERWE. " '5'
PERFORM BDC_FIELD USING 'PLKOD-STATU'
WA_TABDATA-STATU. " '4'
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'PLKOD-QPRZIEHVER'.
PERFORM BDC_FIELD USING 'PLKOD-SLWBEZ'
WA_TABDATA-SLWBEZ. " '200'
PERFORM BDC_FIELD USING 'PLKOD-QPRZIEHVER'
WA_TABDATA-QPRZIEHVER. " 'ACTIVE'
PERFORM BDC_FIELD USING 'PLKOD-CHRULE'
'1'. " With change number
PERFORM BDC_FIELD USING 'PLKOD-CCOAA'
'1'. " Change Type for all objects
PERFORM BDC_DYNPRO USING 'SAPLCPDA' '1200'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=VOUE'.
LOOP AT ITST_TABCTRL1 INTO WA_TABCTRL1 WHERE MATNR = WA_TABDATA-MATNR
AND WERKS = WA_TABDATA-WERKS
AND PLNNR = WA_TABDATA-PLNNR.
AND AENNR = WA_CHECK-AENNR.
ON CHANGE OF WA_TABCTRL1-MATNR OR WA_TABCTRL1-WERKS OR WA_TABCTRL1-PLNNR." OR WA_TABCTRL1-AENNR.
PERFORM BDC_DYNPRO USING 'SAPLCPDI' '1400'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'PLPOD-LTXA1(01)'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'/00'.
CONCATENATE 'PLPOD-ARBPL(' LV_IDX1 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL1-ARBPL. " 'qc01'
CONCATENATE 'PLPOD-STEUS(' LV_IDX1 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL1-STEUS. " 'qm01'
CONCATENATE 'PLPOD-LTXA1(' LV_IDX1 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL1-LTXA1. " 'opearation1'
PERFORM BDC_DYNPRO USING 'SAPLCPDI' '1400'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'PLPOD-VORNR(01)'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=QMUE'.
PERFORM BDC_FIELD USING 'RC27X-ENTRY_ACT'
'1'.
PERFORM BDC_FIELD USING 'RC27X-FLG_SEL(01)'
'X'.
PERFORM BDC_DYNPRO USING 'SAPLQPAA' '0150'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'PLMKB-STELLEN(01)'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'/00'.
LOOP AT ITST_TABCTRL2 INTO WA_TABCTRL2 WHERE MATNR = WA_TABCTRL1-MATNR AND
WERKS = WA_TABCTRL1-WERKS AND
PLNNR = WA_TABCTRL1-PLNNR.
AND AENNR = WA_TABCTRL1-AENNR.
AND ARBPL = WA_TABCTRL1-ARBPL AND
STEUS = WA_TABCTRL1-STEUS.
LV_GOTO = LV_PG * 140. " For Page Down on Second Table Control
IF LV_IDX2 >= 14.
PERFORM BDC_DYNPRO USING 'SAPLQPAA' '0150'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'RQPAS-AB_MKNR'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'/00'.
PERFORM BDC_FIELD USING 'RQPAS-AB_MKNR'
LV_GOTO .
LV_IDX2 = 2.
LV_PG = LV_PG + 1.
PERFORM BDC_DYNPRO USING 'SAPLQPAA' '0150'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'/00'.
ELSE.
PERFORM BDC_DYNPRO USING 'SAPLQPAA' '0150'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'PLMKB-STELLEN(01)'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'/00'.
ENDIF.
CONCATENATE 'PLMKB-VERWMERKM(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-VERWMERKM. " 'MIC00001'/ ' MIC00050'
IF WA_TABCTRL2-PMETHODE <> SPACE.
CONCATENATE 'PLMKB-PMETHODE(' LV_IDX2')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-PMETHODE. " 'met00001'
CONCATENATE 'PLMKB-PMTVERSION(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-PMTVERSION. " '1'
CONCATENATE 'PLMKB-STICHPRVER(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-STICHPRVER." 'APIFX1'
CONCATENATE 'PLMKB-PRUEFEINH(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-PRUEFEINH. " '20'
CONCATENATE 'PLMKB-PROBEMGEH(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-PROBEMGEH. " 'G'
IF WA_TABCTRL2-STELLEN <> SPACE.
CONCATENATE 'PLMKB-STELLEN(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-STELLEN." '2'
ENDIF.
IF WA_TABCTRL2-MASSEINHSW <> SPACE.
CONCATENATE 'RQPAS-MASSEINHSW(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-MASSEINHSW. " '%'
ENDIF.
IF WA_TABCTRL2-SOLLWERT <> SPACE.
CONCATENATE 'QFLTP-SOLLWERT(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-SOLLWERT." '10'
ENDIF.
IF WA_TABCTRL2-TOLERANZUN <> SPACE.
CONCATENATE 'QFLTP-TOLERANZUN(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-TOLERANZUN." '5'
ENDIF.
IF WA_TABCTRL2-TOLERANZOB <> SPACE.
CONCATENATE 'QFLTP-TOLERANZOB(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-TOLERANZOB." '15'
ENDIF.
IF WA_TABCTRL2-DUMMY10 <> SPACE.
CONCATENATE 'PLMKB-DUMMY10(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-DUMMY10." Info Field 1
ENDIF.
IF WA_TABCTRL2-DUMMY20 <> SPACE.
CONCATENATE 'PLMKB-DUMMY20(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-DUMMY20." Info Field 2
ENDIF.
IF WA_TABCTRL2-DUMMY40 <> SPACE.
CONCATENATE 'PLMKB-DUMMY40(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-DUMMY40." Info Field 3
ENDIF.
PERFORM BDC_DYNPRO USING 'SAPLQPAA' '1501'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=ENT1'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'PLMKB-VERWMERKM'.
PERFORM BDC_DYNPRO USING 'SAPLQPAA' '1502'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=ENT1'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'PLMKB-PMETHODE'.
PERFORM BDC_DYNPRO USING 'SAPLQPAA' '1502'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=ENT1'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'PLMKB-PMETHODE'.
PERFORM BDC_DYNPRO USING 'SAPLQPAA' '0150'.
CONCATENATE 'PLMKB-MERKNR('LV_IDX2')' INTO LV_FNAM.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
LV_FNAM.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=QMAM'.
PERFORM BDC_FIELD USING 'RQPAS-ENTRY_ACT'
'1'.
IF LV_IDX2 = 1. " If only one entry then select it
CONCATENATE 'RQPAS-SEL_FLG('LV_IDX2')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
'X'.
ELSE.
LV_IDX = LV_IDX2 - 1. " Deselect previous entry and select current one
CONCATENATE 'RQPAS-SEL_FLG('LV_IDX')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
CONCATENATE 'RQPAS-SEL_FLG('LV_IDX2')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
'X'.
ENDIF.
PERFORM BDC_DYNPRO USING 'SAPLQPAA' '0160'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=QMBW'.
PERFORM BDC_FIELD USING 'PLMKB-KURZTEXT'
'Description'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'PLMKB-QERGDATH'.
PERFORM BDC_FIELD USING 'PLMKB-QERGDATH'
'01'. " Quality Certificate
ELSE.
CONCATENATE 'PLMKB-PMTVERSION(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-PMTVERSION. " '1'
CONCATENATE 'PLMKB-STICHPRVER(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-STICHPRVER." 'APIFX1'
CONCATENATE 'PLMKB-PRUEFEINH(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-PRUEFEINH. " '20'
CONCATENATE 'PLMKB-PROBEMGEH(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-PROBEMGEH. " 'G'
IF WA_TABCTRL2-STELLEN <> SPACE.
CONCATENATE 'PLMKB-STELLEN(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-STELLEN." '2'
ENDIF.
IF WA_TABCTRL2-MASSEINHSW <> SPACE.
CONCATENATE 'RQPAS-MASSEINHSW(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-MASSEINHSW. " '%'
ENDIF.
IF WA_TABCTRL2-SOLLWERT <> SPACE.
CONCATENATE 'QFLTP-SOLLWERT(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-SOLLWERT." '10'
ENDIF.
IF WA_TABCTRL2-TOLERANZUN <> SPACE.
CONCATENATE 'QFLTP-TOLERANZUN(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-TOLERANZUN." '5'
ENDIF.
IF WA_TABCTRL2-TOLERANZOB <> SPACE.
CONCATENATE 'QFLTP-TOLERANZOB(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-TOLERANZOB." '15'
ENDIF.
IF WA_TABCTRL2-DUMMY10 <> SPACE.
CONCATENATE 'PLMKB-DUMMY10(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-DUMMY10." Info Field 1
ENDIF.
IF WA_TABCTRL2-DUMMY20 <> SPACE.
CONCATENATE 'PLMKB-DUMMY20(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-DUMMY20." Info Field 2
ENDIF.
IF WA_TABCTRL2-DUMMY40 <> SPACE.
CONCATENATE 'PLMKB-DUMMY40(' LV_IDX2 ')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
WA_TABCTRL2-DUMMY40." Info Field 3
ENDIF.
PERFORM BDC_DYNPRO USING 'SAPLQPAA' '1501'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=ENT1'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'PLMKB-QMTB_WERKS'.
PERFORM BDC_FIELD USING 'PLMKB-VERWMERKM'
WA_TABCTRL2-VERWMERKM.
PERFORM BDC_FIELD USING 'PLMKB-QPMK_WERKS'
WA_TABCTRL2-WERKS.
PERFORM BDC_FIELD USING 'PLMKB-QMTB_WERKS'
PERFORM BDC_DYNPRO USING 'SAPLQPAA' '0150'.
CONCATENATE 'PLMKB-MERKNR('LV_IDX2')' INTO LV_FNAM.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
LV_FNAM.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=QMAM'.
PERFORM BDC_FIELD USING 'RQPAS-ENTRY_ACT'
'1'.
IF LV_IDX2 = 1. " If first entry select it
CONCATENATE 'RQPAS-SEL_FLG('LV_IDX2')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
'X'.
ELSE.
LV_IDX = LV_IDX2 - 1. " Deselect Previous entry ans select current one
CONCATENATE 'RQPAS-SEL_FLG('LV_IDX')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
CONCATENATE 'RQPAS-SEL_FLG('LV_IDX2')' INTO LV_FNAM.
PERFORM BDC_FIELD USING LV_FNAM
'X'.
ENDIF.
PERFORM BDC_DYNPRO USING 'SAPLQPAA' '0160'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=QMBW'.
PERFORM BDC_FIELD USING 'PLMKB-KURZTEXT'
'Description'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'PLMKB-QERGDATH'.
PERFORM BDC_FIELD USING 'PLMKB-QERGDATH'
'01'. " Quality Certificate
ENDIF.
LV_IDX2 = LV_IDX2 + 1.
ENDLOOP.
ENDON.
ENDLOOP.
PERFORM BDC_DYNPRO USING 'SAPLQPAA' '0150'.
PERFORM BDC_FIELD USING 'BDC_CURSOR'
'RQPAS-ENTRY_ACT'.
PERFORM BDC_FIELD USING 'BDC_OKCODE'
'=QMBU'.
PERFORM BDC_FIELD USING 'RQPAS-ENTRY_ACT'
'1'.
CALL TRANSACTION C_QP01 USING ITST_BDCDATA
MODE C_A UPDATE C_S
MESSAGES INTO ITST_MSGTAB. "#EC CI_CALLTA
ENDLOOP.
ENDFORM. " F_START_BDC
*& Form UPLOAD_EXCEL_FILE
text
--> p1 text
<-- p2 text
FORM UPLOAD_EXCEL_FILE .
CALL FUNCTION 'ALSM_EXCEL_TO_INTERNAL_TABLE'
EXPORTING
FILENAME = P_FNAME
I_BEGIN_COL = 1
I_BEGIN_ROW = 2
I_END_COL = 24
I_END_ROW = 9999
TABLES
INTERN = IT_FILE_UPLOAD.
ENDFORM. " UPLOAD_EXCEL_FILE
*& Form CONFIRM_UPLOAD
text
--> p1 text
<-- p2 text
FORM CONFIRM_UPLOAD .
CALL FUNCTION 'POPUP_TO_CONFIRM'
EXPORTING
TITLEBAR = TEXT-002
TEXT_QUESTION = TEXT-003
IMPORTING
ANSWER = GV_ANS
EXCEPTIONS
TEXT_NOT_FOUND = 1
OTHERS = 2.
ENDFORM. " CONFIRM_UPLOAD
*& Form BDC_DYNPRO
text
-->P_0589 text
-->P_0590 text
FORM BDC_DYNPRO USING PROGRAM
DYNPRO.
CLEAR: ITST_BDCDATA.
ITST_BDCDATA-PROGRAM = PROGRAM.
ITST_BDCDATA-DYNPRO = DYNPRO.
ITST_BDCDATA-DYNBEGIN = 'X'.
APPEND ITST_BDCDATA.
ENDFORM. " BDC_DYNPRO
*& Form BDC_FIELD
text
-->P_0729 text
-->P_0730 text
FORM BDC_FIELD USING FNAM
FVAL.
CLEAR: ITST_BDCDATA.
ITST_BDCDATA-FNAM = FNAM.
ITST_BDCDATA-FVAL = FVAL.
APPEND ITST_BDCDATA.
ENDFORM. " BDC_FIELD
*& Form ORGANIZE_UPLOADED_DATA
text
--> p1 text
<-- p2 text
FORM ORGANIZE_UPLOADED_DATA .
DATA : LV_TOTROW TYPE I, " Total Records
LV_ROW TYPE I. " Row No
LV_TOTROW = 1.
SORT IT_FILE_UPLOAD BY ROW
COL.
LOOP AT IT_FILE_UPLOAD.
LV_TOTROW = IT_FILE_UPLOAD-ROW. " To find total rows
ENDLOOP.
LV_ROW = 1.
WHILE LV_ROW <= LV_TOTROW.
LOOP AT IT_FILE_UPLOAD WHERE ROW = LV_ROW.
CASE IT_FILE_UPLOAD-COL.
WHEN '0001'. " Material
TRANSLATE IT_FILE_UPLOAD-VALUE TO UPPER CASE.
WA_TABDATA-MATNR = IT_FILE_UPLOAD-VALUE.
WA_TABCTRL1-MATNR = IT_FILE_UPLOAD-VALUE.
WA_TABCTRL2-MATNR = IT_FILE_UPLOAD-VALUE.
WHEN '0002'. " Plant
TRANSLATE IT_FILE_UPLOAD-VALUE TO UPPER CASE.
WA_TABDATA-WERKS = IT_FILE_UPLOAD-VALUE.
WA_TABCTRL1-WERKS = IT_FILE_UPLOAD-VALUE.
WA_TABCTRL2-WERKS = IT_FILE_UPLOAD-VALUE.
WHEN '0003'. " Group Key
WA_TABDATA-PLNNR = IT_FILE_UPLOAD-VALUE.
WA_TABCTRL1-PLNNR = IT_FILE_UPLOAD-VALUE.
WA_TABCTRL2-PLNNR = IT_FILE_UPLOAD-VALUE.
WHEN '0004'. " Change Number
WA_TABDATA-AENNR = IT_FILE_UPLOAD-VALUE.
WA_TABCTRL1-AENNR = IT_FILE_UPLOAD-VALUE.
WA_TABCTRL2-AENNR = IT_FILE_UPLOAD-VALUE.
WHEN '0004'. " Group Counter Desc
WA_TABDATA-KTEXT = IT_FILE_UPLOAD-VALUE.
WHEN '0005'. " Usage
WA_TABDATA-VERWE = IT_FILE_UPLOAD-VALUE.
WHEN '0006'. " Status
WA_TABDATA-STATU = IT_FILE_UPLOAD-VALUE.
WHEN '0007'. " Inspection Point
WA_TABDATA-SLWBEZ = IT_FILE_UPLOAD-VALUE.
WHEN '0008'. " Sample Drawing Procedure
WA_TABDATA-QPRZIEHVER = IT_FILE_UPLOAD-VALUE.
WHEN '0009'. " Work Centre
WA_TABCTRL1-ARBPL = IT_FILE_UPLOAD-VALUE.
WA_TABCTRL2-ARBPL = IT_FILE_UPLOAD-VALUE.
WHEN '0010'. " Control Key
WA_TABCTRL1-STEUS = IT_FILE_UPLOAD-VALUE.
WA_TABCTRL2-STEUS = IT_FILE_UPLOAD-VALUE.
WHEN '0011'. " Desc
WA_TABCTRL1-LTXA1 = IT_FILE_UPLOAD-VALUE.
WHEN '0012'. " MIC
WA_TABCTRL2-VERWMERKM = IT_FILE_UPLOAD-VALUE.
WHEN '0013'. " Method
WA_TABCTRL2-PMETHODE = IT_FILE_UPLOAD-VALUE.
WHEN '0014'.
WA_TABCTRL2-PMTVERSION = IT_FILE_UPLOAD-VALUE.
WHEN '0014'. " Sampling
WA_TABCTRL2-STICHPRVER = IT_FILE_UPLOAD-VALUE.
WHEN '0015'.
WA_TABCTRL2-PRUEFEINH = IT_FILE_UPLOAD-VALUE.
WHEN '0016'.
WA_TABCTRL2-PROBEMGEH = IT_FILE_UPLOAD-VALUE.
WHEN '0017'. " Accuracy
WA_TABCTRL2-STELLEN = IT_FILE_UPLOAD-VALUE.
WHEN '0018'. " Unit
WA_TABCTRL2-MASSEINHSW = IT_FILE_UPLOAD-VALUE.
WHEN '0019'. " Target Value
WA_TABCTRL2-SOLLWERT = IT_FILE_UPLOAD-VALUE.
WHEN '0020'. " Lower Limit
WA_TABCTRL2-TOLERANZUN = IT_FILE_UPLOAD-VALUE.
WHEN '0021'. " Upper Limit
WA_TABCTRL2-TOLERANZOB = IT_FILE_UPLOAD-VALUE.
WHEN '0022'. " Info Field1
WA_TABCTRL2-DUMMY10 = IT_FILE_UPLOAD-VALUE.
WHEN '0023'. " Info Field2
WA_TABCTRL2-DUMMY20 = IT_FILE_UPLOAD-VALUE.
WHEN '0024'. " Info Field3
WA_TABCTRL2-DUMMY40 = IT_FILE_UPLOAD-VALUE.
ENDCASE.
ENDLOOP.
LV_ROW = LV_ROW + 1.
INSERT WA_TABDATA INTO TABLE ITST_TABDATA .
APPEND WA_TABCTRL1 TO ITST_TABCTRL1.
APPEND WA_TABCTRL2 TO ITST_TABCTRL2.
CLEAR :WA_TABDATA,WA_TABCTRL1,WA_TABCTRL2.
ENDWHILE.
ENDFORM. " ORGANIZE_UPLOADED_DATA
E N D - O F - S E L E C T I O N *
END-OF-SELECTION.
Free all internal tables
FREE: ITST_TABDATA,
ITST_TABCTRL1,
ITST_TABCTRL2.
Maybe you are looking for
-
I recently unlocked my iphone 4. I am trying to use it on Net 10's network. However, i cannot access the network settings. I have the Net10 Sim already in it. A few notes listed below of what i have tried: 1.) I downloaded the iphone configuation uti
-
IPhone 3G running iOS 4.0 is no longer recognized in iTunes
My iPhone 3G, which I had successfully (after much labor) upgraded to iOS 4.0, started having problems yesterday. I was getting this message after downloading some photos: "An iPhone has been detected but it could not be identified properly Please di
-
Specs posted below...omit the 2000+ for a shitty 800mhz duron right now. A week ago, this board fried my athlon xp 2000+. somehow, after trying over and over again, I got the duron 800mhz that I have to work, and its working, but this is stupid. T
-
Hello, I would like to link my ECC 6.0 system with an (outdated..) 620 Content server This works fine for non secure data Now I would like to enable signed url's. for this you need to enable security=1 in the Content server .ini file. Furrthermore yo
-
Photo editor for macbook pro similar to afterlight, vsco cam, whitagram?
photo editor for macbook pro similar to afterlight, vsco cam, whitagram?