Changing height of a row in a table control

Hi all,
I have developed a webdynpro application in which i am using a table control in the view. Can anyone tell me how can i change the height of a row in the table control?
thanx in advance
anuradha

hi anuradha,
you can set the number of the rows to be displayed, in the table controller properties, so that those many rows will be disaplayed at a time.
to do this.
Go to table controller properties,
mention the integer( number of rows to be displayed ) value in the <b>visiblerowcount</b> property.
if your requirement is not this then let me know.
bye.
Brahmanandam.

Similar Messages

  • Changing number of rows oin a table control dynamically

    Hi all
    Is there a way to change the no of rows dynamically.
    I have a requirement that at run time , depending on a condition, I have to change the no of rows in the table control to 1 row.
    Is this possible to do?If else How?
    Thanks.

    You can redefine table control attributes eachtime PBO is called, because those attributes are dynamic. So although you defined tc-lines as 1 in first PBO execution, you can redefine to 2 if some condition is achieved,
    One idea could be to create a global var, called tc_lines which is initialized as 1. In your PBO you shoud use: <tc>-lines = tc_lines.
    In PAI, when you obtain your condition, you shoud here add or subract one from this global variable.
    Regards,
    Valter Oliveira.

  • How to display particular ROW of a table control in display/change mode

    Hi,
    Can we make particular ROW in a table control display mode or editable mode depending upon the conditions?.
    Any inputs..
    Rgds,
    Lakshmiraj

    Hi,
    Yes it is possible. check the follwoing code for help.
    *&  Include           Z101954_ASSIGNMENT1I01
    *&      Module  VALIDATE_SALES_ORG  INPUT
          text
    MODULE validate_sales_org INPUT.
    SELECT SINGLE zvkorg FROM vbak INTO zvbak-zvkorg
    *WHERE zvbeln = zbookhdr-zvbeln.
    IF sy-subrc <> 0.
       MESSAGE 'INVALID AIRLINE ID INPUT' TYPE 'I'.
       CALL SCREEN 1000.
    ENDIF.
    ENDMODULE.                 " VALIDATE_SALES_ORG  INPUT
    *&      Module  USER_COMMAND_1001  INPUT
          text
    MODULE user_command_1001 INPUT.
      var3 = 1.
      IF sy-ucomm <> 'SAVE'.
        PERFORM material_check.
        IF sy-subrc <> 0.
          MESSAGE 'ENTER THE CORRECT MATERIAL NUMBER' TYPE 'I'.
        ELSE.
          SELECT SINGLE zmaktx zmeins zwaerk zstprs FROM zmara
            INTO CORRESPONDING FIELDS OF it_salesitems
             WHERE zmatnr = it_salesitems-zmatnr.
          SELECT SINGLE zwerks zlgort FROM zorg
            INTO CORRESPONDING FIELDS OF it_salesitems
            WHERE zvkorg = wa_salesorder-zvkorg
             AND zvtweg = wa_salesorder-zvtweg
             AND zspart = wa_salesorder-zspart.
          it_salesitems-znetwr = it_salesitems-zstprs * it_salesitems-zbrgew.
         MODIFY it_salesitems FROM it_salesitems  INDEX sy-tabix.
          MOVE-CORRESPONDING it_salesitems TO temp_salesitems.
          APPEND temp_salesitems.
          REFRESH it_salesitems.
        ENDIF.
      ENDIF.
    LOOP AT temp_salesitems.
      if it_salesitems-pick = 'X'.
               LOOP AT SCREEN.
             IF screen-name EQ 'DETAIL'.
               screen-input = 1.
               MODIFY SCREEN.
             ENDIF.
           ENDLOOP.
           endif.
           endloop.
      CASE sy-ucomm.
        WHEN 'SAVE'.
          PERFORM check_ship_to_party.
          IF sy-subrc <> 0.
            MESSAGE 'ENTER THE CORRECT SHIP TO PARTY ' TYPE 'I'.
          ELSE.
            PERFORM check_payer.
            IF sy-subrc <> 0.
              MESSAGE 'ENTER THE CORRECT PAYER' TYPE 'I'.
            ELSE.
              PERFORM check_bill_to_party.
              IF sy-subrc <> 0.
                MESSAGE 'ENTER THE CORRECT BILL TO PARTY' TYPE 'I'.
              ELSE.
                wa_salesorder-zernam = sy-uname.
                MOVE-CORRESPONDING wa_salesorder TO zvbak.
                MODIFY zvbak.
                LOOP AT it_salesitems.
                  it_salesitems-zvbeln = wa_salesorder-zvbeln.
                  MOVE-CORRESPONDING it_salesitems TO zvbap.
                  MODIFY zvbap.
                ENDLOOP.
                IF sy-subrc = 0.
                  MESSAGE 'THE DATA IS SAVED SUCCESSFULLY' TYPE 'I'.
                  CLEAR wa_salesorder.
                  REFRESH it_salesitems.
                  REFRESH temp_salesitems.
                  IF sy-tcode = 'ZVA01'.
                    CALL SCREEN '1000'.
                  ELSE.
                    CALL SCREEN '1003'.
                  ENDIF.
                ENDIF.
              ENDIF.
            ENDIF.
          ENDIF.
        WHEN 'DETAIL'.
          CALL SCREEN '1002'.
        WHEN 'BACK'.
          IF sy-tcode = 'ZVA03'.
            CLEAR wa_salesorder.
            CALL SCREEN '1003'.
          ELSE.
            PERFORM pop_up.
          ENDIF.
        WHEN 'EXIT'.
          IF sy-tcode = 'ZVA03'.
            LEAVE PROGRAM.
          ELSE.
            PERFORM pop_up.
          ENDIF.
        WHEN 'CANCEL'.
          IF sy-tcode = 'ZVA03'.
            CLEAR wa_salesorder.
            CALL SCREEN '1003'.
          ELSE.
            PERFORM pop_up.
          ENDIF.
      ENDCASE.
    ENDMODULE.                 " USER_COMMAND_1001  INPUT
    *&      Module  input_help_sold_to_party  INPUT
          text
    MODULE input_help_sold_to_party INPUT.
      SELECT zkunag FROM zvbak INTO CORRESPONDING FIELDS OF TABLE
        itab.
      CALL FUNCTION 'F4IF_INT_TABLE_VALUE_REQUEST'
        EXPORTING
      DDIC_STRUCTURE         = ' '
          retfield               = 'ZKUNAG'
      PVALKEY                = ' '
         dynpprog               = sy-cprog
         dynpnr                 = '1000'
         dynprofield            = 'ZKUNAG'
      STEPL                  = 0
      WINDOW_TITLE           =
      VALUE                  = ' '
         value_org              = 'S'
      MULTIPLE_CHOICE        = ' '
      DISPLAY                = ' '
      CALLBACK_PROGRAM       = ' '
      CALLBACK_FORM          = ' '
      MARK_TAB               =
    IMPORTING
      USER_RESET             =
        TABLES
          value_tab              = itab
      FIELD_TAB              =
      RETURN_TAB             =
      DYNPFLD_MAPPING        =
    EXCEPTIONS
      PARAMETER_ERROR        = 1
      NO_VALUES_FOUND        = 2
      OTHERS                 = 3
      IF sy-subrc <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
            WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
      ENDIF.
    ENDMODULE.                 " input_help_sold_to_party  INPUT
    *&      Form  pop_up
          text
    -->  p1        text
    <--  p2        text
    FORM pop_up .
      CALL FUNCTION 'POPUP_TO_CONFIRM'
        EXPORTING
      TITLEBAR                    = ' '
      DIAGNOSE_OBJECT             = ' '
          text_question               = 'DO YOU WANT TO SAVE THE ORDER?'
         text_button_1               = 'YES'(001)
         icon_button_1               = ' '
         text_button_2               = 'No'(002)
         icon_button_2               = ' '
         default_button              = '1'
         display_cancel_button       = 'X'
         userdefined_f1_help         = ' '
      START_COLUMN                = 25
      START_ROW                   = 6
      POPUP_TYPE                  =
      IV_QUICKINFO_BUTTON_1       = ' '
      IV_QUICKINFO_BUTTON_2       = ' '
    IMPORTING
         answer                      = ans
    TABLES
      PARAMETER                   =
    EXCEPTIONS
      TEXT_NOT_FOUND              = 1
      OTHERS                      = 2
      IF sy-subrc <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
            WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
      ENDIF.
      CASE ans.
        WHEN '001'.
          PERFORM check_ship_to_party.
          IF sy-subrc <> 0.
            MESSAGE 'ENTER THE CORRECT SHIP TO PARTY ' TYPE 'I'.
          ELSE.
            PERFORM check_payer.
            IF sy-subrc <> 0.
              MESSAGE 'ENTER THE CORRECT PAYER' TYPE 'I'.
            ELSE.
              PERFORM check_bill_to_party.
              IF sy-subrc <> 0.
                MESSAGE 'ENTER THE CORRECT BILL TO PARTY' TYPE 'I'.
              ELSE.
                wa_salesorder-zernam = sy-uname.
                MOVE-CORRESPONDING wa_salesorder TO zvbak.
                MODIFY zvbak_101954.
                temp_salesitems-zvbeln = wa_salesorder-zvbeln.
                MOVE-CORRESPONDING temp_salesitems TO zvbap.
                MODIFY zvbap.
                IF sy-subrc = 0.
                  MESSAGE 'THE DATA IS SAVED SUCCESSFULLY' TYPE 'I'.
                  CLEAR wa_salesorder.
                  REFRESH it_salesitems.
                  REFRESH temp_salesitems.
                  IF sy-ucomm = 'EXIT'.
                    LEAVE PROGRAM.
                  ENDIF.
                  IF sy-tcode = 'ZVA01'.
                    CALL SCREEN '1000'.
                  ELSE.
                    CALL SCREEN '1003'.
                  ENDIF.
                ENDIF.
              ENDIF.
            ENDIF.
          ENDIF.
        WHEN '002'.
          IF sy-tcode = 'ZVA01'.
            CLEAR wa_salesorder.
            REFRESH it_salesitems.
            REFRESH temp_salesitems.
            CALL SCREEN '1000'.
          ELSE.
            CLEAR wa_salesorder.
            REFRESH it_salesitems.
            REFRESH temp_salesitems.
            CALL SCREEN '1003'.
            CLEAR ans.
          ENDIF.
      ENDCASE.
    ENDFORM.                    " pop_up
    *&      Module  USER_COMMAND_1002  INPUT
          text
    MODULE user_command_1002 INPUT.
    IF sy-datar = 'X'.
       PERFORM material_check.
       IF sy-subrc <> 0.
         MESSAGE 'ENTER THE CORRECT MATERIAL' TYPE 'I'.
       ELSE.
         SELECT SINGLE zmaktx zmeins zwaerk zstprs FROM zmara_101954
         INTO CORRESPONDING FIELDS OF wa_salesitems
           WHERE zmatnr = wa_salesitems-zmatnr.
         wa_salesitems-znetwr =  wa_salesitems-zstprs * wa_salesitems-zbrgew.
       ENDIF.
       var = 1.
    ENDIF.
      IF sy-ucomm = 'BACK'.
        LOOP AT temp_salesitems.
          MODIFY temp_salesitems FROM wa_salesitems .
        ENDLOOP.
        it_salesitems-pick = ' '.
        CALL SCREEN '1001'.
      ENDIF.
    ENDMODULE.                 " USER_COMMAND_1002  INPUT
    *&      Module  USER_COMMAND_1000  INPUT
          text
    MODULE user_command_1000 INPUT.
      CASE sy-ucomm.
        WHEN 'NEXT'.
          SELECT * FROM zt001k_101954 INTO CORRESPONDING FIELDS OF
            temp_salesorder WHERE
            zvkorg = wa_salesorder-zvkorg AND
            zvtweg = wa_salesorder-zvtweg AND
            zspart = wa_salesorder-zspart.
          ENDSELECT.
          IF sy-subrc = 0.
            CALL SCREEN '1001'.
          ELSE.
            MESSAGE 'Invalid Data Entered' TYPE 'I'.
            CALL SCREEN '1000'.
          ENDIF.
      ENDCASE.
    ENDMODULE.                 " USER_COMMAND_1000  INPUT
    *&      Module  USER_COMMAND_1003  INPUT
          text
    MODULE user_command_1003 INPUT.
      IF sy-ucomm = 'NEXT'.
       IF sy-datar = ' '.
         MESSAGE 'ENTER PURCHASE ORDER NUMBER' TYPE 'I'.
         CALL SCREEN 1000.
        IF NOT wa_salesorder-zvbeln CO '0123456789'.
          MESSAGE 'PURCHASE ORDER NUMBER IS NOT IN THE EXPECTED FORMAT' TYPE 'I'.
          CALL SCREEN '1003'.
        ENDIF.
        var3 = 0.
        CALL SCREEN '1001'.
      ENDIF.
    ENDMODULE.                 " USER_COMMAND_1003  INPUT
    *&      Module  input_help_sales_order  INPUT
          text
    MODULE input_help_sales_order INPUT.
      SELECT zvbeln FROM zvbak_101954 INTO CORRESPONDING FIELDS OF TABLE
      itab1.
      CALL FUNCTION 'F4IF_INT_TABLE_VALUE_REQUEST'
        EXPORTING
      DDIC_STRUCTURE         = ' '
          retfield               = 'ZVBELN'
      PVALKEY                = ' '
         dynpprog               = sy-cprog
         dynpnr                 = '1003'
         dynprofield            = 'ZVBELN'
      STEPL                  = 0
      WINDOW_TITLE           =
      VALUE                  = ' '
         value_org              = 'S'
      MULTIPLE_CHOICE        = ' '
      DISPLAY                = ' '
      CALLBACK_PROGRAM       = ' '
      CALLBACK_FORM          = ' '
      MARK_TAB               =
    IMPORTING
      USER_RESET             =
        TABLES
          value_tab              = itab1
      FIELD_TAB              =
      RETURN_TAB             =
      DYNPFLD_MAPPING        =
    EXCEPTIONS
      PARAMETER_ERROR        = 1
      NO_VALUES_FOUND        = 2
      OTHERS                 = 3
      IF sy-subrc <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
            WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
      ENDIF.
    ENDMODULE.                 " input_help_sales_order  INPUT
    *&      Module  back_command  INPUT
          text
    module back_command input.
    *if sy-ucomm = 'SAVE' OR 'BACK' OR 'DETAIL' OR 'EXIT' OR 'CANCEL'.
    *endif.
    endmodule.                 " back_command  INPUT
    Regards
    Rajesh Kumar

  • Reg:Rows display in Table Control

    Dear All,
             I created a Table Control which is displaying 30 rows in the initial screen.But my requirement is to display up to 200 rows in
    the initial screen itself how can it be done??

    Try to change the Vis Length column of the table control....
    All you can do is make the Table Control visible to the entire screen....it will display the number of rows which it can in the that screen....
    Rest will be availabe via vertical and horizontal scroll bars.

  • Insert row and delete row in a table control

    Hi Experts,
    I am using a table control in module pool programming, How can I Insert row and delete row in a table control?
    Thanks in Advance....

    Santhosh,
    Iam using this code..
    FORM fcode_delete_row
                  USING    p_tc_name           TYPE dynfnam
                           p_table_name
                           p_mark_name   .
    -BEGIN OF LOCAL DATA----
      DATA l_table_name       LIKE feld-name.
    data: p_mark_name type c.
      FIELD-SYMBOLS <tc>         TYPE cxtab_control.
      FIELD-SYMBOLS <table>      TYPE STANDARD TABLE.
      FIELD-SYMBOLS <wa>.
      FIELD-SYMBOLS <mark_field>.
    -END OF LOCAL DATA----
      ASSIGN (p_tc_name) TO <tc>.
    get the table, which belongs to the tc                               *
      CONCATENATE p_table_name '[]' INTO l_table_name. "table body
      ASSIGN (l_table_name) TO <table>.                "not headerline
    delete marked lines                                                  *
      DESCRIBE TABLE <table> LINES <tc>-lines.
      LOOP AT <table> ASSIGNING <wa>.
      access to the component 'FLAG' of the table header                 *
        ASSIGN COMPONENT p_mark_name OF STRUCTURE <wa> TO <mark_field>.
    if <MARK_FIELD> = 'X'.
        PERFORM f_save_confirmation_9101.
        IF gv_answer EQ '1'.
          DELETE <table> INDEX syst-tabix.
          IF sy-subrc = 0.
            <tc>-lines = <tc>-lines - 1.
          ENDIF.
          ELSE.
          ENDIF.
        ENDIF.
      ENDLOOP.
    in this code   ASSIGN COMPONENT p_mark_name OF STRUCTURE <wa> TO <mark_field>.
    if <MARK_FIELD> = 'X'.
    this code is not working...

  • Get the count of rows in a table control

    Hi Experts,
      How do I get the count of the rows in a table control during run time.
    I am developing a BDC in which I have to check all entries in a table control.
    My requirement is to get the total number of rows in a table control dynamically.
    Thanks
    Kumar

    Hi,
    Use a variable when u r passing the records from the internal table to the screen fields
    and display the same.
    I think this idea may help u.
    And pls explain me ur requirement clearly.
    Refer to the following link this may help u.
    http://sapabapnotes.blogspot.com/2008/03/working-with-ecatt-extended-computer.html
    Reward if helpful.
    Jagadish

  • Can you programmatically change the width of columns in a table control\indicator

    Is it possible to programmatically change the width of columns in a table control\indicator ie to fit to width of the data or in my case the header information.

    Create a property node (or reference) and use the 'Active Cell' property to select which column you want to change and then use the 'Cell size'--> 'Width' property to change the size.
    "There is a God shaped vacuum in the heart of every man which cannot be filled by any created thing, but only by God, the Creator, made known through Jesus." - Blaise Pascal
    Attachments:
    table.vi ‏33 KB

  • Locking a particular row in a table control

    Hi All,
    I have module pool program in which table control is used. I would like to know whether it is possible to lock a particular row in the table so that another person will not be able to edit it until the first user completes his work. It should be only for that particular record which is being currently edited in the table.

    Hi,
      Yes you can lock particular row in a table control..
      In the flow logic..
    PROCESS BEFORE OUTPUT.
      LOOP AT itab INTO wa WITH CONTROL tc.
         MODULE disable_row.
      ENDLOOP.
      MODULE disable_row.
    * call the Enqueue function module..If the
        IF sy-subrc NE 0.
          LOOP AT screen.
               SCREEN-INPUT = 0.    " Disable for input
               MODIFY SCREEN.
          ENDLOOP.
       ENDIF.
      ENDMODULE.
    Thanks
    Naren

  • Insert row in a table control

    Hi,
    I have a requirement to insert a new row and delete an existing row from a table control.
    Please help me how to proceed with this.
    Thanks in advance.
    Suresh

    Hi,
    Sorry for wrongly framed question.
    The question is
    I have a requirement to insert a new <b>column</b> and delete an existing <b>column</b> from a table control.
    Thanks,
    Suresh

  • What is the maximum number of row for a table control in LabWindows/CVI ?

    I use LabWindows CVI 8.5.1 (MMI first developped in version 6.0).
    In one of our many MMI, a table control contains a list of aircraft parameters.
    We can add as many parameters (row) as we want but over 40 000 we observe a crash of the LabWindows CVI runtime.
    Our client want to inscrease the number of parameters (row) up to 200 000 !!!
    So my questions are:
    What is the real maximum number of row for the table control ?
    Is this maximum number of row different on LabWindows 2010 version ?
    Or is there an other solution ?
    Thanks

    Greetings,
    Can you clarify what you mean by "crash"? Is there an error message thrown? Is it possible that you've consumed all of the available memory?
    Please let me know.
    Thanks, James Duvall
    Product Support Engineer
    National Instruments

  • Highlighting one row in a table control

    Hi All,
    Can i highlight one row in a table control. I found some stroke color in the properties for a field in table control. But i am not sure, will it be applied to the entire column or to a particular field.
    Anybody aware of this.?
    Regards,
    Manjunatha.T.S

    Hi,
    This is not currently available in VC.
    Lior

  • How to change background color of row of a table in a panel table

    hi! im trouble right now, somebody help me. i have a matrix of row and column, panel row and panel table in jsp. my problem is how can i change the background color of a row once it clicked. i have row in table which have panel table with panel column and panel row.
    i have already work for it but i only change the background color once i clicked is the first row and first column then the rest row and column is not working..pls.. give me sample code for it..thnx a lot!!!
    Thnank's,
    froilet

    Ok! I have 2 jsp, the input jsp and display.jsp! Once i input value on input.jsp, it will display on display.jsp. I have also my javascript named updateBin.js. Now, how can i update each row once i clicked it... the succeeding rows and columns..hope u help me with this..here is my code:
    Display.jsp
    <html:html locale="true">
    <head>
         <html:base/><meta http-equiv="content-type" content="text/html; charset=utf-8" />
    <title>Strip Map Loader</title><script type="text/javascript" src="js/updateBin.js"></script>
    </head>
         <%      
              int intRow = Integer.parseInt(request.getParameter("intRows"));
              int intColumn = Integer.parseInt(request.getParameter("intColumns"));
              int intPanelRow = Integer.parseInt(request.getParameter("intPanelRows"));
              int intPanelColumn = Integer.parseInt(request.getParameter("intPanelColumns"));
         %>
    <BODY bgcolor="#33b9ec" leftmargin="50%">
         <b>Strip ID:  </b><font color="red" face="arial"><b><bean:write name="strStripID" scope="request" /></b></font>
         <br><br>
         <font size="3" face="tahoma"><b>Bins Updater Tool:</b></font>
         <table border="1" width="365px" bgcolor="#1ea6f7" height="15">
              <tr>
                   <td valign="top" align="center">
                        <table><tr><td><font size="2">Select Bin Type:</font></td>
                        <td><select id="binType" onchange="updateBin()" size="1">
                             <OPTION></OPTION>
                             <OPTION value="green">Good Bin</OPTION>
                             <OPTION value="red">Reject Bin</OPTION>
                        </select></td></tr></table>
                   </td>
    </tr>
    </table>
    <table id="tbl" align="center" border="1" cellspacing="3" cellpadding="5" bgcolor="#CC9900">
    <tr>
    <td>                                                  
         <%for (int pnlrows=1; pnlrows<=intPanelRow; pnlrows++){%>     
              <table id="table" width="100%" border="1" bgcolor="#CC9900" cellspacing="7" cellpadding="0" align="center">
              <tr>
              <%for(int pnlcols=0; pnlcols<intPanelColumn;pnlcols++){%>               
              <td>
                        <%for (int rows=1;rows<=intRow; rows++){%>                    
                        <table cellspacing="5" width="100px" align="center" bgcolor="#CC9900">
                        <tr>
                             <td>                    
                             <%for(int cols=1; cols<intColumn; cols++){%>
                             </td>     
                             <td id="col" bgcolor="#008000" align="center" ondblclick="changeCol()"> X </td>          
                             <%}%>
                             <td id="row" bgcolor="#008000" align="center" ondblclick="changeRow()"> X </td>
                             <td></td>     
                             <%}%>                                                  
                        </tr>
                        </table>
              <%}%>
              </td>
              </tr>
              </table>     
         <%}%>
    </td>
    </tr>
    </table>
    and this is my javascript code:
         function updateBin()
              var binType=document.getElementById("binType")
              if(binType.value == "green")
              [binType.selectedIndex].value
              //binType = changeR();
              //alert('Good Bin Selected');
              if(binType.value == "red")
              [binType.selectedIndex].value
              //binType = changeC();
              //alert('Reject Bin Selected');
              if(binType.value == "")
                   alert('Please select only on the category!')
         function changeRow()
              if(binType.value=="green")
              x=document.getElementById('row').style.background="green";     
              alert('Updated!')     
              if(binType.value=="red")
              x=document.getElementById('row').style.background="red";
              //alert('Reject Bin Updated!')
         function changeCol()
              if(binType.value=="green")
                   x=document.getElementById('col').style.background="green";     
                   alert('Updated!')     
              if(binType.value=="red")
              x=document.getElementById('col').style.background="red";
              //alert('Reject Bin Updated!')
    this code only updates the first row and column..but the succeeding panel row and panel column can't update...what will i do? theres something wrong in my javascript or in my jsp...pls help me......thanx.....in advance!!

  • How to change the number displaying rows in a table

    Hi all,
    i have a table for resources in Debrief Work order (Standard Screen), we need to change the default displaying rows. inistially it displayed 3 empty rows.
    i tried to change the Records Displayed for the table but it did not affect.
    also it is possible to change the "Add 3 rows" button in the table to add for example 5 rows instead?
    any idea?
    Regards,
    Mahdi Charara

    Hi,
    Through personalization we can do.On standared page top right u will find personalization link.click on the clink next expand all there find apporiate table .Here u will fine reorder button set as u want display and save. then u can see the change.For add row functionality u need to extend the co.

  • To insert a new row in a table control without affecting the other rows

    Halo experts,
    I have a Table control TCTRL in a program .
    The lt_tab contains two cols A and B
    In change mode of the transaction Col A is in display mode and Col B is in change mode
    When i press the + button to insert a new blank entry .I need a blank row with both col A and col B input enabled w/o affecting the display of above and below rows of table control
    In PBO module of subscreen 101
    LOOP AT lt_tab  WITH CONTROL tctrl.
    MODULE tctrl_status.
    endloop.
    In the user command of 0101
    i am writn
    When 'INS'.
    INSERT INITIAL LINE INTO itab.
    Inside MODULE tctrl_status.
    IF lt_tab IS INITIAL.
        LOOP AT SCREEN.
          IF screen-name = 'COLA'.
          screen-input = 1.
      ENDIF.
        ENDLOOP.
          MODIFY SCREEN.
    endif.
    but the problem here is still the Col A is in display mode and Col B is in change mode after output
    .Here modify statement is happening but it does not update the TCTRL-COLS-Screen structure for the col A ( which I have set statically while designing the screen ).I dont want to make the entire row in edit mode only the inserted row ( for both Col A and Col B) and the rest shud remain as it is
    Thanks
    Kallu

    hi Naveen
    I have made my tctrl input disabled for both the columsn and
    I have a module before the PBO loop where I set the like
    module set_tctrl_status.
    IF gv_ok_code NE gc_disp.
        LOOP AT tctrl-cols INTO gs_cols.
          IF gs_cols-screen-name = 'ColB'.
            gs_cols-screen-input = 1.
            MODIFY tctrl-cols FROM gs_cols INDEX sy-tabix.
          ENDIF.
        ENDLOOP.
    This is just to set the Col B in edit mode when in change and create status.
    But if i press the INS button for that change i am coding inside the loop endloop of the pBO like
    if itab is initial.
    LOOP AT tctrl-cols INTO gs_cols.
    gs_cols-screen-input = 1.
    MODIFY tctrl-cols FROM gs_cols INDEX sy-tabix.
    endloop.
    But the problems i it is setting the enite rows as input enabled . I want tos et only that row inpur enabled

  • Disable rows of a table control

    Hi Experts,
      I want to disable a row in table control, whenever SAVE is pressed.
      Scenario: A Table control having 5 rows. User entered data in the first row and pressed SAVE, then
                    that particular row should become greyed out or disabled, so that the user cant change or edit
                    anymore.
    Thanks
    Chandan

    Hi Chandan,
    in the PBO write the code to make the field display by the below logic..
    first read the table control internal table line and check whether the field is filled if the field had value make it display mode else make it input filed..
    see the below logic how to write it..
    PROCESS BEFORE OUTPUT.
    * Table control for OUTPUT
      LOOP AT t_zcxref_classes INTO wa_zcxref_classes
           WITH CONTROL tc_batch .
        MODULE charac_classname_out.            
      ENDLOOP.
    MODULE charac_classname_out OUTPUT.
    * Table control reading values from input screen & displaying on screen
      READ TABLE t_zcxref_classes INTO wa_zcxref_classes
                                INDEX tc_batch-current_line.
    * Logic for screen Display when Required Flag = 'D'
      IF wa_zcxref_classes-required_flag is not intial.      "if the input field has some value making as disaply
        LOOP AT SCREEN.
          IF screen-name = 'WA_ZCXREF_CLASSES-ATWRT'. "field to make as display
            screen-input = 0.
          ENDIF.
          MODIFY SCREEN.
        ENDLOOP.
      ENDIF.
    ENDMODULE.                
    Regards,
    Prabhudas

Maybe you are looking for

  • Search Help to populate field

    Hie guys, As a work around to my clients request i have modified an elementary search help in transaction CV02N. Instead of showing customers under the Obect Links i am showing the business partners. however when the desired business partner is selec

  • Transferring Data from Hierarchy

    Hi Experts, We have a complex bespoke hierarchy in system, consisting of several/different levels of granularity. Hierarchy looks like as follows: <b>- Root</b> <b>-- Level 1.1</b> <b>----Level 1.1.1</b> <b>------Level 1.1.1.1</b> Leaf 1 Leaf 2 <b>--

  • Rendering Asian Fonts (1.4.2_05)

    Hi, I have an application which has to render multiple languages simultaneously. I've not been able to render japanese text without renaming the font.properties.ja file in the JRE directory to font.properties. But when I do this russians characters a

  • Address Book duplicates some names.

    The address book duplicates parts of the names of those I sent to. Example: Babineau Babineau Cheryl Currier Nita D. Currier D. Miller Harvey Harvey But not every person to whom I send has their name duplicated as above. I have used "Edit" on these a

  • Where should I save my free trial of adobe acrobat pro?

    where should I save my free trial of adobe acrobat pro?