Hi,
I have been using the Frame API for CAN communication and now I am working on making a simpler application which will utilize a database file that I will specify in MAX.  The database file only consists of messages that my LabVIEW application will write to the device and does not contain the messages that the device will send to my LabVIEW application.  I tried to run a write command to see if data is actually being written and an error came up pointing me to the nicanErr.txt file and said that I should talk to someone at NI to work through this problem.  Attached is the vi, the .ncd file, and the text file.  Can someone tell me what I am doing wrong?
Thanks,
Gary
Attachments:
Channel API.zip ‏24 KB

Hello,
Sorry about that, I have attached the file as an 8.2 file.
You can navigate to the NI-CAN 2.6 drivers page .  You will have to be logged in to your NI profile.
In the readme you should find that your PCMCIA CAN device is supported by the driver version.
Let me know how this goes.
Thank you. 
Christian A
National Instruments
Applications Engineer
Attachments:
main_modified.vi ‏36 KB

Similar Messages

  • DI API Error Code - 1, Error Message - General Error while adding order

    Hi All,
        While adding sales order using di api(in .net web application), i receives error(code-1, message-general error) if some particular items are inserted as line items. For all other items, it works fine.
        I put code to export the order to be added as xml if its giving such error. Then I have written one vb code which accepts xml as input and adds order from it. I tried exported xml with this application and it worked, without any change in exported xml order.
        So I thought if general error comes, .net web page should export order xml and import it again and then use add method. But its not working. Though exported xml gets imported and order gets created if I use the other vb code(i run this after some 5 to 10 min, after order is not created from web application).
        Please help me out of this problem.
    Thanks and Regards,
    Yogesh.

    Hi Yogesh,
    I am not sure about the cause for your problem, but I would recommend to:
    a) use SQL Profiler to find out (hopefully) where the transaction actually breaks and
    b) involve SAP Support to find out what doesn't work when you use these particular items.
    HTH,
    Frank

  • CAN error with Channel API

    Hello All,
    Right now i am facing a CAN error when run my script which was developed using channel APIs. I am not able to trace out the the reason of the error. Pls find attached code and Error description. I have uploaded the sample code here and I am writing several messages in the same VI as same like in the code. Pls guide me in this
    Thanks in advance
    Anoop
    Attachments:
    CAN Channel API error.JPG ‏22 KB
    Channel API test.vi ‏29 KB

    Hi Anoop,
    Is the code you posted the exact code you are using when you get the error?  The reason I ask is, usually this error is associated with using the Set Property VI after the interface has already been started, such as in a loop.
    Are you able to use any examples from the Example Finder successfully? (Help > Find Examples)  You can Browse to CAN examples by clicking Hardware Input and Output > CAN > Channel API.
    Hope this helps!
    Adam W
    Applications Engineering
    National Instruments

  • Wininet error code -105

    I have reinstalled my windows xp i know it is discontinued
    was trying to reinstall a very old game pharoh
    i received wininet error code -105
    not a computer genius what should i do it said see online help 

    I'm not 100% sure, so maybe check other forums that reported similar issues. Here is one:
    http://answers.microsoft.com/en-us/windows/forum/windows_7-windows_programs/error-105/7adb126a-2bea-41b2-9718-29831dceb61f
    This error code is definitely not related to Bing Ads API error code 105.. that much I can say.
    I hope this helps!

  • URGENT:upgrade to 3.0.8 issue Call to WPG_SESSION API Failed.Error-Code:6550

    I ran upgrade scripts to 3.0.8 from 3.0.6 and completed with no errors.
    csh diag.csh reports no errors.
    sqlplus to connect string works fine
    DAD connect string is correct.
    err text:
    Call to WPG_SESSION API Failed.
    Error-Code:6550
    Error TimeStamp:Tue, 5 Jun 2001 03:36:50 GMT
    Database Log In Failed
    TNS is unable to connect to destination. Invalid TNS address supplied or destination is not listening. This error can also occur because of underlying network transport problems.
    Verify that the TNS name in the connectstring entry of the DAD for this URL is valid and the database listener is running.
    DIAG.CSH output
    oracle(dba)@ws12:/export/home/upgrade:$csh diag.csh -s portal30 -p portal30 ->
    Begining Portal Diagnostics
    ...portal_schema: portal30
    ...portal_password: *************
    ...connect_string: iforce
    Loading java class for Portal Diagnostics ...SQL*Plus: Release 8.1.6.0.0 - Production on Mon Jun 4 20:48:59 2001
    (c) Copyright 1999 Oracle Corporation. All rights reserved.
    Connected to:
    Oracle8i Enterprise Edition Release 8.1.6.0.0 - Production
    With the Partitioning option
    JServer Release 8.1.6.0.0 - Production
    SQL> SQL> Creating Table 'wwsec_diagnostic$'
    Creating Sequence 'wwsec_diagnostic_seq'
    Diagnostics Report v 1.0: Oracle Portal v 3.0.8.9.8
    As of 04-Jun-2001 20:49:02 Schema Name: PORTAL30 SSO Schema Name: portal30_sso
    PORTAL30.wwsec_enabler_config_info$
    Login Server URL : http://ws12.sempi.eng.sun.com:7777/pls/portal30_sso/portal30_sso.wwsso_app_admin.ls_login
    DAD : portal30_sso
    Host connection : successful.
    mod_plsql : working.
    JServ : working.
    Schema name : portal30_sso
    Connect string : iforce
    Authentication mode : Single Sign-On
    portal30_sso.wwsec_enabler_config_info$
    Login Server URL : http://ws12.sempi.eng.sun.com:7777/pls/portal30_sso/portal30_sso.wwsso_app_admin.ls_login
    DAD : portal30_sso
    Host connection : successful.
    mod_plsql : working.
    JServ : working.
    Schema name : portal30_sso
    Connect string : iforce
    Authentication mode : Single Sign-On
    Partner Application Information
    **** Oracle Portal (portal30) ****
    Home URL : http://ws12.sempi.eng.sun.com:7777/pls/portal30/portal30.home
    Success URL : http://ws12.sempi.eng.sun.com:7777/pls/portal30/portal30.wwsec_app_priv.process_signon
    DAD : portal30
    Host connection : successful.
    mod_plsql : working.
    JServ : working.
    Schema name : portal30
    Connect string : iforce
    Authentication mode : Single Sign-On
    **** The Login Server (portal30_sso) ****
    Home URL : http://ws12.sempi.eng.sun.com:7777/pls/portal30_sso/portal30_sso.home
    Success URL : http://ws12.sempi.eng.sun.com:7777/pls/portal30_sso/portal30_sso.wwsso_home.process_signon
    DAD : portal30_sso
    Host connection : successful.
    mod_plsql : working.
    JServ : working.
    Schema name : portal30_sso
    Connect string : iforce
    Authentication mode : Single Sign-On
    Diagnostics completed successfully!
    Disconnected from Oracle8i Enterprise Edition Release 8.1.6.0.0 - Production
    With the Partitioning option
    JServer Release 8.1.6.0.0 - Production
    null

    Venu
    Have you also upgraded your 9iAS instance to 1.0.2.2? The WPG_SESSION API error commonly appears when you are not using the lastest version of mod_plsql contained in 1.0.2.2.
    See: Migration Guide for Oracle9iAS Solaris or NT/2000.

  • Call to WPG_SESSION API Failed. Error-Code:6550

    Can someone please help me figure out what I may be doing wrong? Using recent downloaded versions of 8i and 9iAS I cannot access Portal30 using IE5 browser. Please see error below. During portal configuration I specified connect string of oracle:1521:dba1. The connectstring entry of the DAD is dba1. I ran ssodatan. The database is open, listener is listening and SQL*Plus, DBA Studio, Net8 Assistant all connect to dba1 fine. Discussions mention cookies, upgrades, etc., but nothing definitive. Troubleshooting Guide does not reference error 6550. I am at a loss. Any suggestions would be appreciated.
    I downloaded and installed 8.1.7 on NT host oracle then downloaded and installed 9iAS on another NT host. Portal Diagnostics are successful, however I get database login failed when attempting to use IE5 browser to access portal at http://oracle/pls/portal30/PORTAL30.home
    Here's the diags:
    D:\ora9ias\portal30\admin\plsql>set ORACLE_HOME=d:\ora9ias
    D:\ora9ias\portal30\admin\plsql>diag -s portal30 -c dba1
    Begining Portal Diagnostics
    ...portal_schema: portal30
    ...portal_password: *************
    ...portal_connect_string: dba1
    Loading java class for Portal Diagnostics ...
    SQL*Plus: Release 8.1.7.0.0 - Production on Wed Jul 25 08:41:58 2001
    (c) Copyright 2000 Oracle Corporation. All rights reserved.
    Connected to:
    Oracle8i Enterprise Edition Release 8.1.7.0.0 - Production
    With the Partitioning option
    JServer Release 8.1.7.0.0 - Production
    Creating Table 'wwsec_diagnostic$'
    Creating Sequence 'wwsec_diagnostic_seq'
    Diagnostics Report v 1.01: Oracle Portal v 3.0.9.8.0
    As of 25-Jul-2001 08:42:17 Schema Name: PORTAL30 SSO Schema Name: portal30
    _sso
    Proxy Server Settings:
    HTTP Server:
    HTTP Server Port:
    No Proxy Servers for Domains beginning with:
    URL Connection Time-Out (seconds):
    PORTAL30.wwsec_enabler_config_info$
    Login Server URL : http://oracle/pls/portal30_sso/portal30_sso.wwsso_app_admi
    n.ls_login
    DAD : portal30_sso
    Host connection : successful.
    mod_plsql : working.
    JServ : working.
    Schema name : portal30_sso
    Connect string : dba1
    Authentication mode : Single Sign-On
    Partner Application Information
    **** The Login Server (portal30_sso) ****
    Home URL : http://oracle/pls/portal30_sso/portal30_sso.home
    Success URL : http://oracle/pls/portal30_sso/portal30_sso.wwsso_home.pro
    cess_signon
    DAD : portal30_sso
    Host connection : successful.
    mod_plsql : working.
    JServ : working.
    Schema name : portal30_sso
    Connect string : dba1
    Authentication mode : Single Sign-On
    **** Oracle Portal (portal30) ****
    Home URL : http://oracle/pls/portal30/portal30.home
    Success URL : http://oracle/pls/portal30/portal30.wwsec_app_priv.process
    _signon
    DAD : portal30
    Host connection : successful.
    mod_plsql : working.
    JServ : working.
    Schema name : portal30
    Connect string : dba1
    Authentication mode : Single Sign-On
    **** The Login Server (portal30_sso) ****
    Home URL : http://oracle/pls/portal30_sso/portal30_sso.home
    Success URL : http://oracle/pls/portal30_sso/portal30_sso.wwsso_home.pro
    cess_signon
    DAD : portal30_sso
    Host connection : successful.
    mod_plsql : working.
    JServ : working.
    Schema name : portal30_sso
    Connect string : dba1
    Authentication mode : Single Sign-On
    Diagnostics completed successfully!
    Disconnected from Oracle8i Enterprise Edition Release 8.1.7.0.0 - Production
    With the Partitioning option
    JServer Release 8.1.7.0.0 - Production
    D:\ora9ias\portal30\ admin\plsql>
    Call to WPG_SESSION API Failed.
    Error-Code:6550
    Error TimeStamp:Wed, 25 Jul 2001 12:33:52 GMT
    Database Log In Failed
    TNS is unable to connect to destination. Invalid TNS address supplied or destination is not listening. This error can also occur because of underlying network transport problems.
    Verify that the TNS name in the connectstring entry of the DAD for this URL is valid and the database listener is running.
    null

    I met that error several times. Check TNS connection from web server box to database server, if applicable. - use tnsping.
    That's the only cause that produces the error. If the web server box has more than one Oracle Home, find the correct one. Check $iAS_home/Apache/bin/apachectl script which will tell you its oracle home directory. It may not use $TNS_ADMIN/tnsnames.ora, but $ORACLE_HOME/network/admin/tnsnames.ora.

  • Why do I get error -1074388985 at CAN Connect Terminals when the Channel API has been stopped?

    While trying to establish synchronized CAN and DAQ using the Channel API, I get the error -1074388985 while attempting to connect the RTSI Clock to the master timebase.  The error message occurs each time I try to run the example VIs shipped with LabVIEW 6.1.  I am using a Series 2 PCI CAN card with a 6034E DAQ card.  Any ideas?  Tech support did not have a solution.

    Hi AVR,
    This warning means you have tried to change an attribute on a running object. This causes the warning and should not take place.
    Use the "Initialize' function instead of the "initStart" Function, then change the Attribute and use the "Start" function to start the communication, or stop the communication using the "stop" Function before you change any Attribute and then start again.
    Hope that helps
    DirkW

  • Error Code -50150 from DAQmx Create Channel (AI-Voltag​e-Basic).v​i

    I have an executable, built from Labview 7.1 VI's. All it is doing is reading 6 voltages back from a 6008 USB-DAQ, and reporting the results back. Occasionally, it is throwing an Error -50150 from DAQmx Create Channel (AI-Voltage-Basic).vi. The full error message is:
    Error Code: -50150
    DAQmx Create Channel (AI-Voltage-Basic).vi<append>
    <B>Task Name: </B>_unnamedTask<0>
    Can anyone shed some light on this problem?
    Cheers.

    Hi fellas,
    I have a really similar problem to the one Neilelph had, but I can´t see how to solve it from your answers. I attached a picture of my main .VI.
    It´s basically a photodiode measurment system working as follows:
    1. First the moving stages for the system get ready (X-Y moving stages for the Photodiode and Z stage for the Laser). That´s the CONFIG subVI in the left.
    2. Then there is a For Loop, that repeats N times depending on the Initial Z, final Z and step values. So in this .VI the laser moving stage is the only one changing.
    3. In each loop, the stages go to the X,Y,Z(t) posiition (MOV subVI), wait for the movement (WAIT subVI) and read the position. After that, the DAQmx acquistion part starts. I just sample the output DC voltage coming from the  Photodiode (Dev1/ao1), 1000 samples in 1 second, and then I make an average of all of them with the Basic DC/rms block. So at the end I have 1 position of Z and one DC value. And it worked perfectly. At least for small number of iterations I have no problems. 
    The problem comes with small steps and a great number of iterations. For example last night I ran a measurement. 10000 iterations, the whole range of Z, and today i checked it. It worked fine until 5000 give or take, the half of the range. From that point, the DC ouput recorded in the .lvm file is just 0.00000. It´s the second time it happens, so I´m wondering what´s wrong because I´m affraid to make more long measurments and obtain the same results. 
    The error message I obtained is the same than in the thread title: -50150  DAQmx Create Channel (AI-Voltage-Basic).vi:6<append> <B>Task Name: </B>_unnamedTask<53BC>
    Maybe it would be useful to mention that, sometimes, there is no error and I have some DC Output Voltage value, for random Z potitions, but since the first error message, that barely happens. The output is almost always 0.
    Sorry for my writting skills in English. I hope you can understand my situation.
    Thank you in advance.
    Kind regards,
    frilance.
    Attachments:
    Diagram.JPG ‏83 KB

  • Call to WPG_SESSION API Failed. Error-Code:20000

    Hi,
    to be short:
    Oracle: 8.1.7.0.0
    When trying to login to the portal application I got this error [bottom of message]
    I downloaded the diag tool and run it against my configuration, everything was reported OK.
    I've also searched all through this forum and have read similar problem, but nobody had error code 20000.
    Would you please guide me?
    Call to WPG_SESSION API Failed.
    Error-Code:20000
    Error TimeStamp:Thu, 29 Mar 2001 16:41:15 GMT
    Database Log In Failed
    TNS is unable to connect to destination. Invalid TNS address supplied or destination is not listening. This error can also occur because of underlying network transport problems.
    null

    Reza,
    Is this a new install?
    If so, on a new install, you often need to create an entry in the tnsnames.ora file within the Oracle9iAS $ORACLE_HOME. You can do this simply by copying the information from your tnsnames.ora in your Oracle 8.1.7 $ORACLE_HOME/network/admin.
    A lot of times, it could also be a difference of Portal trying to connect to the database with:
    ORA817.company.com
    instead of
    ORA817
    or vice versa.
    Check http://myhost.mydomain.com/pls/admin_/gateway.htm
    In each DAD, it will specify the connect string that Portal is trying to use to connect with. Make sure your tnsnames.ora is using the same.
    If this is not a new install, you may have just had a problem with the database. If this is not production, rather than debugging the problem connecting to the database. I have found that restarting the database and webserver usually works, that will at least get you back up and running. Then you can check the alert.log in the database for any problems or issues such as too many sessions, etc.
    Thanks,
    Sue

  • Digital I/O board 9478 error code 65548 overcurrent report by channel

    Hi All,
    We are investigating overcurrent on digital outputs. This project is using the Scan Engine instead of FPGA.
    Reading one of the hardware shared variables gives the error code 65548 - One or more channels are in overcurrent or overvoltage protection mode.
    If we used FPGA would we be able to determine which channel is in overcurrent?
    Thanks,
    Paul

    Hello Paul,
    Yes, it can. You can use Module I/O Method and it will indicate if the module runs into overcurrent or not. The previous like is for the 9269, but it also works for the 9478. Remember that if you are using LabVIEW 2012, you won’t be able to create a method by right clicking on the I/O variable because of a known bug. A workaround for this is to open the example “NI 9269 Status Methods.lvproj” and add your target. Then you can right click on the method » Select Item » select your module.
    Regards,
    Daniel REDS
    RF Systems Engineer
    Help us grow.
    If a post solves your question, mark it as The Solution.
    If a post helps, give Kudos to it.

  • Error code -88708 with DAQmx Create Channel (AI-Voltage-Basic)

    Hi,
    I am trying to construct a VI that moves a piezoelectric stage, the VI then needs to scan voltages from the DAQ card to build up arrays of the voltage and coordinates before constructing a 3D graph.
    The VI successfully moves the stage and reads the position back to me but when it tries to scan voltages from the DAQ it fails (I'm using the DAQmx Create Channel (AI-Voltage-Basic).vi example, as this has been used in a previous, similar (and successful) VI within my department.)
    I get the following error code:
    Error -88708 occurred at DAQmx Create Channel (AI-Voltage-Basic).vi
    Possible reason(s):
    The specified resource is not available. The operation could not be completed as specified.
    Task Name: _unnamedTask<1>
    Any help on this would be appreciated - I'm fairly new to LabView and am at a loss with how to fix this!
    Thanks
    -Tom

    Is this working when you restart the computer? It might be that the recources are still recerved because the Clear Task.vi wasn't executed (either it`s not present or you did use the abort button).
    Felix
    www.aescusoft.de
    My latest community nugget on producer/consumer design
    My current blog: A journey through uml

  • Call to WPG_SESSION API Failed. Error-Code:20001

    Here is the error I am getting while accessing portal. This error comes 2 out of 5 times.:
    Call to WPG_SESSION API Failed.
    Error-Code:20001
    Error TimeStamp:Fri, 23 Mar 2001 17:28:33 GMT
    Database Log In Failed
    TNS is unable to connect to destination. Invalid TNS address supplied or destination is not listening. This error can also occur because of underlying network transport problems.
    Verify that the TNS name in the connectstring entry of the DAD for this URL is valid and the database listener is running.

    The error code implies an invalid cookie. This could be because the encryption key is invalid or the format of the cookie is corrupted. If the encryption key was invalid, the error would happen all of the time rather than 2 times out of 5. The only way I can see that the cookie format would be bad is if it got truncated. There is a 4K limit on the size of the buffer that passes cookies around, so it could be that the browser is sending more than 4k worth of cookies. However, if this were the case, then the error would be consistent from that browser after you exceeded the limit. Can you give a little more detail on exactly what you are doing when the error occurs?

  • Unknown error in reservation system (API error type A code 3)

    Good Day
    I hope someone can give me some info for the following error.
    I create a travel plan and when I click on Book I do some times get the following error
    "Unknown error in reservation system (API error type A code 3)"
    Can anyone please assist, as this does not always happens.
    Regards
    Jaco Nel

    MONO PKGBUILDs have a number of unique requirements. Have a look at some of the official ones, like Banshee itself, or F-spot, for example.

  • Direct Entitlement API - passing error code

    Hi,
    I'm trying to implement login API in our DPS application. I can see that there is a possibility to provide an errorCode in the SignInWithCredentials action.
    Error Results:
    HTTP 401 Unauthorized
    Body:
    <result httpResponseCode=”401” errorCode=””/>
    How can I read this error code on the app side (in login action from adobeDPS.authenticationService.login(username.val(), password.val()); ) ?
    Will it be available in the error field of this transaction ?
    Or I should retrieve it some other way ?
    I need this error code to show revelant message to the user that din't succeed to log in.
    regards,
    Piotr

    But I get -150 (TransactionAuthenticationUnrecognizedCredentialsError) no matter what errorCode i set in the XML response.
    And I'd like to get the error code which I've set on the server.
    Can I pass a custom code there somehow ?
    Or I need to set the error code to one of the values from that list ?
    Adobe DPS - Library and Store SDK 2.32 : adobeDPS-TransactionErrorType : JsDoc Reference

  • [svn:osmf:] 14488: PARB changes: Mark some APIs as @private ( logging and error codes).

    Revision: 14488
    Revision: 14488
    Author:   [email protected]
    Date:     2010-03-01 15:25:19 -0800 (Mon, 01 Mar 2010)
    Log Message:
    PARB changes: Mark some APIs as @private (logging and error codes).  They're not critical to expose right now, we'll review them, lock them down, and expose them publicly in time for 1.0.
    Modified Paths:
        osmf/trunk/framework/OSMF/org/osmf/events/MediaErrorCodes.as
        osmf/trunk/framework/OSMF/org/osmf/logging/ILogger.as
        osmf/trunk/framework/OSMF/org/osmf/logging/ILoggerFactory.as
        osmf/trunk/framework/OSMF/org/osmf/logging/Log.as
        osmf/trunk/framework/OSMF/org/osmf/logging/TraceLogger.as
        osmf/trunk/framework/OSMF/org/osmf/logging/TraceLoggerFactory.as

    Remember that Arch Arm is a different distribution, but we try to bend the rules and provide limited support for them.  This may or may not be unique to Arch Arm, so you might try asking on their forums as well.

Maybe you are looking for