Characteristic USITMMPE is blocked by conversion
I tried to activate an InfoObject and I got:
Characteristic USITMMPE is blocked by conversion. Now I am unable to make any change to this InfoObject. How to unblocked it? Thanks.
Did you change the data type/DDIC for the info-objects. If yes, then delete the data first before acitvating it
refer: info object activation problem
Similar Messages
-
Characteristic 0MATERIAL is blocked by conversion
Hi experts,
I am transporting the 0MATERIAL changes into production (after extra navigational attribute added), while importing into production system, its giving below error message.
Characteristic 0MATERIAL is blocked by conversion
the new navigational attribute is active in production system.
how to resolve this issue?
regards
venuscmHi,
Kindly review this SAP Note 1177708 - CHECK: Change time-dependent attribute to time-independent
For existing data, a time-dependent attribute can only be changed to time-independent if there is exactly one attribute value for each characteristic value in the existing data. Even though there are several attribute values, the check may in some cases report values to be unique. However, the characteristic activation terminates. The subsequent inconsistent state can be cleared only manually.
Please also read & follow the recommendations in SAP Notes:
325296 Conversion lock: Characteristics cannot be edited
451773 Inactive characteristic cannot be activated (inact.
Rgds,
Colum -
Characteristic 0BPARTNER is blocked by conversion(Status 6)
Hi
I have added added 3 attributes to 0bparnter while activating error came.i removed 2 atributes and activated againg i got error :Characteristic 0BPARTNER is blocked by conversion(Status 6) .infoobject has data which loading from crm.i found sapnote_0000325296 can i apply.do i need delete data or without also possible to apply this note.Hello,
Adding an attribute should not be a problem in any infoobject.
You can delete the data from the infoobject if its not used in any cube or if the cubes where its used are not loaded or contains no data.
Otherwise you will have to delete the data from the cubes first and then from infoobject.
This will allow you to change the infoobject.
Even the OSS notes looks old one..so just do a verification if its already applied or not.
Regards
Ajeet -
Characteristic ZEMPLYETD is blocked by conversion
hi
i am geting this error while activating of time depandant of employee. ple let em know
Characteristic ZEMPLYETD is blocked by conversionHi,
check below link,
R7476 - Characteristic OMATERIAL is blocked by conversion
Regards,
Viren -
Characteristic Infoobject is blocked by conversion
Dear All,
Getting message as(Characteristic Infoobject is blocked by conversion).
Unable to activate the infoobject.
Does anybody faced the issue before.
Thanks.Did you change the data type/DDIC for the info-objects. If yes, then delete the data first before acitvating it
refer: info object activation problem -
Characteristic 0EMPLOYEE is blocked by conversion
Hi Gurus.
I added 2 Attributes to 0EMPLOYEE infoobject and made them navigational. Now, when I try to activate 0EMPLOYEE it times out and I get this message when I come and try to enter edit mode for 0EMPLOYEE:
Characteristic 0EMPLOYEE is blocked by conversion
Message no. R7476
Diagnosis
The conversion of master data tables from characteristic 0EMPLOYEE is not completed.
System Response
Characteristic 0EMPLOYEE can not be changed until this conversion has been successfully carried out.
Procedure
Activate characteristic 0EMPLOYEE. The block will be removed following a successful activation.Hi Dinah,
Yes, I was able to fix this.
You need to do the following. In BW, go to tcode SE14 (ABAP Dictionary: Database Utility). Enter the table name that is causing the problem in the Obj. name field. In my case that was the SID table, e.g. /BIC/YEMPLOYEE. You can display all the infoobject tables by typing in EMPLOYEE (your InfoObject name) and F4 for lookup.
Once you type in the correct table name, click on Edit button. On another screen, click on Delete data radio button. Then do an Activate and adjust database. If that does not fix it ..also ..come back and click on Delete database table button.
Hope this helps.
Thanks -
Characteristic 0TCTUSERNM is blocked by conversion
Dear All,
I am trying to activate the infoobject 0TCTUSERNM but it is giving error as below,
Characteristic 0TCTUSERNM is blocked by conversion
Message no. R7476
Diagnosis
The conversion of master data tables from characteristic 0TCTUSERNM is not completed.
System Response
Characteristic 0TCTUSERNM can not be changed until this conversion has been successfully carried out.
Procedure
Activate characteristic 0TCTUSERNM. The block will be removed following a successful activation.
When I activate the infoobject, it is giving short dump.
Does anyone have faced such issues?
I tried force conversion in SE14 and also tried to activate and adjust tables in SE14 for this infoobject. It didn't helped.
Any pointers to solve the issue will be helpful.
Regards,
NirajHi,
I tried both the options suggested by you. Deleted the table from SE14 and adjust and activate. The issue did not resolved.
i tried activation in background and job was getting cancelled.
To solve the issue I went to infoobject> Extras>Remove conversion lock
it gace a warning and then activated manually.
Thanks for all the suggestions.
Regards,
Niraj -
Characteristic 0BPARTNER is blocked by conversion
Hello,
I´m trying to activate 0BPARTNER characteristic but it is blocked by conversion. System sais that problem will be solved activating 0BPARTNER but it is impossible to do it:
Message no. R7476
Diagnosis
The conversion of master data tables from characteristic 0BPARTNER is not completed.
System Response
Characteristic 0BPARTNER can not be changed until this conversion has been successfully carried out.
Procedure
Activate characteristic 0BPARTNER. The block will be removed following a successful activation.
But I can´t activate it.
Best regards,
CarmenI had a colleague reinstall the object from BCT- additionally he also activated a few related datasources in R/3 (RSA5) and then activated 0BPARTNER and it was successful!!
I guess I was facing some authorization glitches due to the recent upgrade to 2004s- note that my colleague and I have the same authorizations- and the exact above steps did not work for me but worked for him!
But thanks all for your valuable suggestions and interest in this thread.
This issues is now closed.
regards
Naresh -
"Characteristic is blocked by conversion" -- "No Nametab Exist"
Hi all,
I have a serious problem. I have an infoobject with master data time dependent. I have switched one field from "Time-Dependent" to "not Time Dependent". In development environment no problem arises.
When transporting in quality environment, the Change request goes in Red with following message:
Table /BI0/PXXX: Error in creating index 0 (2)
Characteristic 0XXX is blocked by conversion
I check in quality and I see that the /BI0/QXXX table is not active. When I try to activate it, the following error message appears:
No active nametab exists for /BI0/QXXX
Termination due to inconsistencies
Table /BI0/QXXX (Statements could not be generated)
Any ideas?
Thanks,
GianlucaOSS Note 211492
-
Characteristic is blocked by conversion (status 4)
Dear all,
There is a infoobject had many nav attributes,and much data in master data table.
And then,i change nav attributes from time-dependent to notime-dependent.
when i active it, there was error,and is blocked by conversion.
So, status of the char is inactive, not executable.
I Delete lock in SM12 ,and it didn't help. Locks appear again.
error message shows the following:
Internal Activation (InfoObject )
Preprocessing / Creation of DDIC Objects for InfoObject ZCO_ELMNT
Characteristic ZCO_ELMNT : Converting the Master Data Tables
Table /BIC/PZCO_ELMNT: Error in creating index 0 (2)
Resetting of Incorrect Objects Back to the Active Version (InfoObject )
Preprocessing / Creation of DDIC Objects for InfoObject ZCO_ELMNT
Characteristic ZCO_ELMNT is blocked by conversion
How to active the IO,or delete the block from IO?
Best regards,
PlatoI was facing this problem in bi 7.0 . the object can be unlocked by using TCODE RSA1OLD.
Go to RSA1OLD.
Double click on the object.
then from menu, choose EXTRAS->REMOVE CONVERSION LOCK.
This will remove the lock and will allow you to change the object.
Change, save and activate the object. (You can skip this and can do from RSA1 also, just remove lock in this case)
Change and save the object from here and come out of your all transactions. (Log Off from system)
Now, as you have changed the object from RSA1OLD T-Code , it might not be type compatible for RSA1.
So, go to RSA1, you will find that object unlocked. Change the same object (For sake of formality) and save and activate the object.
This will create the active version of object in RSA1.
Your problem is solved now.
Hope this will work for you. -
0Material is blocked by conversion when transporting from Dev to quality Bo
Hi All,
I am transporting omaterial , I had selected with data flow before option while creating the transport request , when importing the request i am getting the following error in the quality box" 0Material is blocked by conversion "i had already transported the table view ( t ocde osml)
Please guide me to resolve this issue .
thanks in Advance
suitable answer will be awardedHi Krishna,
Goto SE14, Give all the relevant tables one by one and Delete data and acivate.
1. SE14
2. Eneter table like /BI0/PMATERAL
3. On the next screen select the option Delete Data and Activate.
4. Repeat step 1 to 3 for all the other tables.
To find out all the tables:
1. Goto Se14
2. /B10/*Materal
3. press F4.
Hope this helps.
best regards,
Kazmi -
Error In InfoObject Activation - Characterstic Blocked By Conversion
When I am going to Activate 0APO_PROD the error message is
1. The SID table for 0APO_PROD cannot be filled
2. The InfoObject 0APO_PROD is Blocked by Conversion.Hi
just on trial basis u can try tcode se14 delte the sid table recreate it and then activate the infoobject
thanks
puneet -
Failed to filter by any characteristic in the block navegacinal an querie
Hello Forum,
I'm giving the following error when trying to filter with a value in any characteristic in the block navigation of the querie:
First, I get the following message:
"No authorization for accesing file dsnutils.err"
and then to try to fix or filter again, gives me a DUMP:
MESSAGE_TYPE_X
Anál.errores
Short text of error message:
Error sist.en progr.SAPLRRK0 and subrut.CHECK_KHANDLE (consider
pl.)
Long text of error message:
Diagnosis
This is an internal errro cancellation selective as the p
state program should not exist.
Procedure
Analyze the situation and report to SAP.
If there has been a cancellation in implementing a qu
Web model or in interaction with the Planning and Modeler és
can play, including a trace (RSTT transaction).
For more information on the recording of a trace, see
documentation on the environment and tools No trace
899572.
Technical information about the message:
Message Class ....... "BRAIN"
Number .............. 299
Variable 1 .......... "SAPLRRK0"
Variable 2 .......... "CHECK_KHANDLE"
Variable 3 .......... ""
Variable 4 .......... ""
Notes to correct errors
Probably the only way to eliminate the error is to correct the program.
If the error occurred in a non-modified SAP program, you may be able to
find an interim solution in an SAP Note.
If you have access to SAP Notes, carry out a search with the following
keywords:
"MESSAGE_TYPE_X"
"SAPLRRK0" or "LRRK0F05"
"CHECK_KHANDLE"
If you can not solve the problem yourself and want to send an error
notification to SAP, include the following information:
1. The description of the current problem (short dump)
To save the description, choose "System-> List-> Save-> Local File
(Unconverted). "
2. Corresponding System log
Display the system by calling transaction log SM21.
Restrict the time interval to 10 minutes before and five minutes
Short after the dump. Then choose "System-> List-> Save-> Local File
(Unconverted). "
3. If the problem occurs in a problem of your own or a modified SAP
program: The source code of the program
In the editor, choose "Utilities-> More
Utilities-> Upload/Download-> Download. "
4. Details about the conditions under which the error occurred or which
Not if you shall know to be the problem, if by any lack of authorization.
A greeting and thanks.See if the table is empty UJA_SVR_DEFAULT, if you run the program and included users UJA3_WRITE_SYS_USERS Domain \ bpc_sys_Admin, Domain \ Domain and bpc_Admin \ bpc_user.
verify that the notes 1481751, 1448691 and 1479393 are applied.
Guilherme Vieira -
Transport Error: Characteristic is blocked by conversion
Hello Everyone,
I had created an Info Object in my development system with some attributes and also compounded with certain other IO. After loading it, I transported it to Quality.
Then I modified the Info Object in development system by adding some navigational attributes and some more compounding. I loaded it again, tested it and then transported it. But it is giving an error now. The log says " The conversion of master data tables from characteristic ZABC is not completed. Characteristic ZABC can not be changed until this conversion has been successfully carried out."
Steps I did to resolve the issue:
1) Deleted the data from Q. Adjusted the tables using SE14 in Q. Collected the object in a new request and transported it again. It dint work.
2) I checked the consistency of tables for this Info Object using SE14. Everything was consistent. There is a SAP Note that talks about this issue: 1248769. But for that I need Basis support.
Why am I facing this problem? Is there a consistent way to solve the issue because this might happen with any info object as we keep modifying the info object's over period of time.
Regards,
AbhishekIt may be because of conversion lock in the characterstic. You can check it in "Extras --> Remove conversion lock" in the characterstic.
-
OBUSOBJECT Blocked for conversion and not getting activated
I have changed the infoobject OBUSOBJECT attribute 0Mainusage fron <b>navigational to display</b> and then tried activating the OBUSOBJECT , , OBUSOBJECT If in the former active version this IO had 0MAINUSAGE as a nav attribute, now, in a revised version, this is just display attribute. surprise that the OBUSOBJECT couldnt be activated by installation.
Please tell me what are the steps now to resolve this. i want to actiovate the OBUSOBJECT in either old active version or activate with new revisions. i am just stuck since it is not getting activated.
please tell if i go to se16 and <b>sdokmia</b> table in first row i put BW* and then in
3 rd row i put what attribute since when i put 0Mainusage (/BI0/OIMAINUSAGE)
it does not show any record what should i put there?? and then what is the next step. if you can help me step by step.
please help me to resolve this
Regards
Soniya KapoorHi Soniya,
If i have understood you properly, you have one attribute of the infoobject navigations, which u changed to display and tried activating and its not getting activated. This particular attribute is used in some othe cube as navigational attribute as well. Without deleting those references, u want to change the infoobject.
If thats the case, you will not be able to activate ur infoobject. All the reference have to be revoved before activating the object. Sorry for that
Regards
Sriram
Maybe you are looking for
-
My LaserWriter Pro 630 thinks it's a LaserJet IIP and prints dirty pages!
I recently aquired a LaserWriter Pro 630, and have been trying to get it to work. I've been using it with a WinXP Pro SP2 laptop as my PowerMac G4 doesn't have a parallel port and my print server has not arrived yet. Basically, the only time it'll pr
-
Hi there, our mac has an IOS version 10.5.8 and i need to update it to 10.6.8 in order to update our itunes account....when i start softwear update it tells me that nothing needs to be updated and i also do not have access to the mac app store...How
-
Apple TV 3 not working with Sony Bravia KLV-26T400A
CURRENT GENERATION APPLE TV (3) Hi I recently bought an ATV 3 which works fine with a Panasonic TV but is not detected on the HDMI input (or any of the others listed in the Sony menu) by a several year old Sony Bravia KLV-26T400A despite the specs sa
-
ITunes 11 has renamed my songs and albums without my permission!
In my itunes, years ago as i acrued single songs, i would edit the song information such as album name, so that each of these singles would appear in one album called "SINGLES." I do not want 10,000 albums in my itunes that all contain one song each.
-
DMVPN + MPLS best-path selection
Dear Community We're in the process of deploying DMVPN as a backup solution to MPLS. All that is working great! The DMVPN wan is dual-cloud, with 2 hub routers in each cloud. Phase 3 (nhrp shortcut) is enabled on all the spokes. For routing, all the