CIF interface: Error transfering material plant
Hello Experts,
I am traying to transfer a material plant across CIF interface. The problem is, when I activate the integration model, it fails. The error message is exactly this: "Location does not exist for external location 1790 , type 1040, and BSG BS"
Any idea what the reson could be?
Many thanks
Aban
Hello Aparna,
I created a new IM and trying to CIF only location. But this time I get another error message complaing that location 1790 type 1002 already exists:
"Text: Location 1790 of type 1002 (BSG BSG1) already exist"
I checked the table /SAPAPO/LOC in APO and realized that location 1790 exists as type 1001. Now I changed it and would like to CIF it as type 1002.
How should I proceed if I change the location type from 1001 to 1002?
Another question: I tried to debug the CIF transfer by implementing an endlos loop in include "ZXCIFU08" (enhancement CIFLOC01) but this seems to have no effect. Is this the right enhancement (on ECC side)?
Thank you for your help
Aban
Similar Messages
-
Material transfers between plants and storage locations report
Hello experts.
I´m looking for some help.
Actually i am looking for a report that show information about material transfers between plants and storage locations. Is there any report that shows the source of the material (plant, storage location) and also shows the target (plant, storage location).
Thanks for your help.Hi,
Though you may not get report for the same , but you can narrow down the check by using the table MSEG or MB51 using the moment types like 311 643 (sd delivery moments )which are for stock transfers .
or if you want storage location stock many reports are available like MMBE, or MB53 etc.
Regards -
Report to Report Interface Error
Hello,
I have a summary query which needs to go to detail query. I used the RSBBS transaction to designate the sender and receiver query. I can see the "go to" option in the context box when I try to link from my summary to detail and see the detail query as available. However, when it tries to transfer, I get the following error. I know these queries are saved and active. I can run them each independently but cannot get the Report-to-Report Interface to work. Any help would be greatly appreciated.
Thanks,
Lynda
error:
query &v2 on infoprovider &v3 can't be assigned to the dataprovider &v1,
because it does not exist on the BW Server.Hi Chandran,
Thank you for your reply and the two links. I am reviewing the assignment details and have a few questions. I currently only have 2 fields assigned - as variables - material and plant.
Everything else is set to generic.
My first query is driven by one date variable which I created which takes a default of January 2008 and pulls Feb - Dec (used offset +1, +2, etc).
The summary report comes up with correct data.
Material Plant UOM Yearly Budgeted Amt Jan/Yr Feb/Yr March/Yr etc
The user then wants to drilldown to detail behind a month. i.e. Jan/Yr
I created the detail query to ask for material and plant which then provides
Material Plant Purchase Order Main Vendor Freight Vendor UOM Qty Recvd Price and Freight Amoutn
There will be multiple Purchase Orders.
One thing I am not sure about transferring fields. Do I need to designate the month/year as a variable in my detail query along with material and plant? I am a bit fuzzy as to the whole process.
Someone I worked with before mentioned that the sending query will pass the fields on the line where you click "go to"????
Thanks for your patience and help...
Lynda -
ALE IDOC Transfering Material Master From One Client to Another Client
I am using ALE Idoc transfering material master from one client to another client with MATMAS msgtype the details of Idoc received on receiver side is showing message i.e no Idoc is selected at receiving side after passing partner number in WE02 transaction.
As I am new to ALE/IDOCS , I am transferring material master from one client to another client with in same system on IDES using ALE/Idocs the details of IDOC received on receiver side is showing message i.e no IDOC is selected at receiving side after passing partner number in WE02 transaction and showing current status 51 instead of 53 i.e no details of IDOC is received at receiver side using MATMAS Message-Type. It is <removed by moderator>
Kindly provide solution.
Naveen
Message was edited by: Naveen Grover
Message was edited by: Manish Kumar : Subject and formatting changedHello Naveen,
If the connection is available (test with SM59 + Connection identifier),
after choosing your Connection you can test the connection:
you might find the idocs with the daate when they where sent in SM58:
The message says in this case there was no service, there might also be other errors like "wrong password" and so on.
After solving the error, you can restart sending the idoc from this screen.
Hope this helps .
Regards,
Gerlinde -
No valid task list for material "" plant "" for selection criteria
I am getting the following error while creating a production order:
No valid task list for material "" plant "" for selection criteria
Does anyone know how to fix this?
thanks,
ScottDear,
1. Check in Order type dependent parameter - OPL8, select your Plant & Order type. In this check the task list, it should be N. then selection priority in OPJF settings
2. Chek the routing valid from date for this material by CA02. The production order start date must be between valid date.
3)Kindly check the routing header.Whether it is for usage 1 and Release status '4'
4) Task list we maintain in OP8B please check and come back.
Regards,
R.Brahmankar
Edited by: R Brahmankar on Nov 19, 2008 9:57 AM -
MFBF window Missing BOM Components error "no material components available"
Hello !!
I need your help.
We are doing MFBF for the material 12345REF.. but appear the window "Missing BOM components" with the error "no material components available".
-We just review that exist a BOM, and it is valid,
- The material has the RepMfg and has the REM profile.
- exist a prod version and it is valid and has activated the RepMfg.
- Route also exist and has the MfgRep.
What could be generating this issue?
Now Im lost!!Dear Marco,
1.Check whether have you created the BOM component's along with a change number with a release key.
2.If so means goto CC02 and set the release key for that change number.
3.Goto KKF6N,enter the parent material number,plant and create the product cost collector for the producvtion version and save
the preliminary cost estimate for this material and then check in MFBF.
check and revert.
Regards
Mangalraj.S -
C+ 131 (Error message) material price will be negative
Hi
While transfering normal stock to project stock, system responding with error message as "material price will be determined negative value".
Material ledger is already activated - Material price indicator is "V" - e.g., if the material price is below 10$ while doing the MB1C: Stock transfer, system responding as said above. If i increase the material price using MR22, system is not giving any error message and allowing me to post. Here, material is spare part (procured from outside).
Is there any config settings which caused the error message ?
Please share your thoughts if anybody has faced this type of error earlier before.
Thanks in advance for your reply.
VVRDear Team,
While cancellation of GRN document system is showing the message like C+ 131 (Error message) material price will be negative.
As per the analysis the concern Po was belongs to 2008 the material price was 85 MAP.Gooda receipt completed on 22.04.2010.The qty of the gr document is 51.
Now we are unable to cancel the GRN document systemis showing the error message like the above mentioned.
Note: My MAP price 11 rs.I need to know howthe system is reduced this level.where i can see that.Kindly advice to proceed further.
Regards,
Suma Nalluri -
SFGD Material Plant to Plant Transfer
Dear Friends,
we were trying to transfer Plant to Plant SFGD Material (Semi Finished Goods) like Aggregate Production Material
like Plant A Bom Created and Cost run also done (all Process). we want to transfer this Plant A to Plant B
however we transferring Only Quantity updating in B Plant NOT VALUE.
kindly advice ..
Regards,
Rajesh GHI,
check your material price in MM03 for both plant
second you are transferring material with special stock means any WBS element in PO?
Regards
kailas Ugale -
Interface errors (crc, in/output, collisions etc.) via snmp
Hi,
I'm trying to understand how to get interface errors via SNMP. I do get stats via SNMP for ifInErrors / ifOutErrors etc, but I'm trying to get output via SNMP for the errors visible via the 'sh int x' command - CRC errors, input / output errors, collisions, runts. giants etc.).
1) The SNMP ifInError / ifOutError seems to give an overall counter of all errors from the time the device has started - Am I correct about this?
2) Is there any way I can get the interface-specific errors noted above via SNMP?
Thanks,
MarioDepends on the device and version of code, but most likely you will get what you want from the CISCO-IF-EXTENSION-MIB. Look at objects like cieIfInRuntsErrs, cieIfInGiantsErrs, and cieIfInFramingErrs. You will also get some ethernet-specific errors from the ETHERLIKE-MIB.
-
Is there an script that can monitor interface errors (input and output errors) and send an email out when it reaches threshold?
Thanks
Sent from Cisco Technical Support iPhone AppSure. Here's an example:
event manager applet error_monitor_GigabitEthernet0/1
event interface name GigabitEthernet0/1 parameter input_errors entry-op ge entry-val 5 entry-type increment poll-interval 10
action 2.0 cli command "enable"
action 3.0 cli command "show int GigabitEthernet0/1 | inc error"
action 4.0 mail server 10.1.1.1 from [email protected] to [email protected] subject "Errors on interface GigabitEthernet0/1" body "
Interface GigabitEthernet0/1 has seen $_interface_delta_value input errors in the past 10 seconds: $_cli_result" -
Open DeviceNet interface error when TestStand call VIs of NI PCI-8532
Hello,
We use NI PCI-8532 was used as DeviceNet master to do functionality test with a slave (AC Drive).
But when open DeviceNet interface, it happen the error.
We can't find the solution and hope to find help from you.
The basic sequence in TestStand is:
1). Call "Open DeviceNet Interface.vi" to open interface and creat interface object.
Interface(master) setting: interface name=dnet0, MAC ID=0, baudrate=125000bps
2). Call "Open DeviceNet IO.vi" to creat DeviceNet IO object.
Device(slave) setting: MAC ID=63
3). Call "Operate DeviceNet Interface.vi" and operation code=start
4). Call "Wait For State.vi"
5). Call "Read DeviceNet IO.vi" to read data from IO object
6). Call "Close Object.vi" to close IO object handle
7). Call "Close Object.vi" to close interface object handle
Remark, these DeviceNet VIs locates at "C:\Program Files\National Instruments\LabVIEW 2012\vi.lib\DeviceNet\VIAPI".
First time to run sequece in TestStand, it can pass to run step 1) to open DeviceNet interface.
But once there is some error with these steps, and it will happen "Open DeviceNet Interface" error (error code=0xBFF62006) when run these steps again.
Then even use LabVIEW DeviceNet example to test, and it happen the same error except restart computer.
The DeviceNet example locates at "C:\Program Files\National Instruments\LabVIEW 2012\examples\NI-Industrial Communications for DeviceNet\Basic Examples\PXI & PCI\MixedCommunication.vi".
Some information more:
PC operate system: Windows XP SP3
LabVIEW version: 2012 SP1
TestStand version: 2012 SP1
PCI 8532 driver version: 2.3.0
Other installed PCI board: PCI 8531 CANOpenThe following errors may be resolved by resetting the CAN, DeviceNET or LIN device:
Error -1074388986 occurred at ...
NI-CAN: (Hex 0xBFF62006) The object is already open in another application. Solutions: Ensure that only one application at a time uses an object , and that you close all objects prior to exiting your application (don't use LabVIEW toolbar's Abort button).
Error -1074388969 occurred at ...
NI-CAN: (Hex 0xBFF62017) This attribute's value must be provided prior to the Open. Solutions: Set the attribute using the Config function before the Open, and do not set the attribute at any later time; Do not configure multiple CAN Objects for the same ID.
SO,you should reset the DeviceNet.
And another similar issue can explain some points of your problem http://digital.ni.com/public.nsf/allkb/7D9383E9BEAD0B21862571640002F687?OpenDocument -
Table to see all screens for particular material, plant combination
Hi,
Anyone can help me to in which table i can find all screens(like basic data,purchasing..etc) for particular material, plant combination?
Regards,
PrabaLook into field PSTAT in table MARA, this should tell you in general which views are created.
Each characters represents a view.
which character is for vwhich view can be obtained in MM50, hit F4 for the field maintenance status.
A different view on the same kind of information is with SE16 for table MSTA -
T code for Material,plant, stock and price data in std sap
Dear All,
In Std SAP is der any t-code to get Material,plant, stock and price data in 1 go..
waiting for ur early reply
Regards
NaineshHi,
Try T.Code: MC.9 and MC.5 etc. These reports will give you total value of the stock but not unit price.
If you are looking at unit price please write a small query using SQVI or append the relevant info structure.
Regards
Srinivas.P -
Error Message: Enter Plant, ME 083 in BAPI_PR_CREATE in Batch Log of batch
Hi Experts,
Am creating the Purc Requisations of EBAN table, by using BAPI_PR_CREATE from my " Z " prog.
They are creating fine, but, in JOB LOG(when scheduled as BATCH JOB), am getting an error as
" ENTER PLANT" of ID is ME # is 083.
I tried all combinations, like populated a value into Procuring plant, Supplying plant, in the folllowing structures of BAPI,(passing follwoing tables)
pritem = it_bapimereqitemimp
pritemx = it_bapimereqitemx
pritemexp = it_bapimereqitem
PRITEMSOURCE = it_BAPIMEREQSOURCE
still getiitng the same error!!!
I debugged, but, culd not able figure it out??
let me know that, Why its so?
How to fix it?
Any SAP NOTE?
thanqHi,
I have the same issue.
Did you ever figure this out ? -
UOM error in Material master.
Hi
When we log on to Spanish language, we are getting error in material master for Unit of measure, that the unit of measure has not been created in the language ES. But same UOM has configured in EN language and its working fine for material, while in Spanish language it appear as *** with error details,
Could you please suggestu2026
regards
VanrajHi,
Extactly you are right..you got to Logon in Languange ES and create the required UOM in t-code CUNI...
this shuld solve the issue..try and revrt back..
Also,In CUNI on top menu Go to-Translation-UOM here maintain Source lang to Target lan
Reg,
JJ
Edited by: Jagsap on Apr 20, 2010 4:10 PM
Edited by: Jagsap on Apr 20, 2010 4:15 PM
Maybe you are looking for
-
I am trying to listen BBC radio news from BBC App, but on pressing the button "live radio" I always get the error "there was an error playing this radio feed". What is the source of this error and how can I remove it?
-
Key Command for "Go to Next Marker" doesn't work properly
Hi there! While using Logic Pro 9.1.8 with Mountain Lion (10.8.2), it seems that the Key Command for "Go to Next/Previous Marker" doesn't work properly. The only effect is, that a grey rectangle moves in the top of the Arrange Area while ignoring the
-
Why is Aperture2iLife so fast on jpg export when compared to Aperture?
I shoot youth sports. On most days I can shoot 1000+ images for 3-4 games. I shoot 70-200mm VR on a D2X in high-speed crop mode to get eight frames/sec so the shots add up fast. Occasionally I switch back to full res but for the most part I am shooti
-
I am beginner in PL/SQL.The Following statement returns only 40 thugh the exact length is 91. SELECT length(1234567891011121314151617181920212223242526272829303132333435363738394041424344454647484950) FROM dual Also, I get the same result whenever th
-