Cisco 2960 Series Switch Architecture

Hi all,
I wanted to know if there is a document or an article which describes 2960 series architecture specifically for model WS-C2960-24-S as there is for 2600 series in the following link:
http://www.cisco.com/c/en/us/support/docs/routers/2600-series-multiservice-platforms/23852-2600-architecture-23852.html
Thanks.

Hi,
You should be able to find the information that you need here:
http://www.cisco.com/c/en/us/support/switches/catalyst-2960-24-s-switch/model.html
Thanks,
Jake

Similar Messages

  • Increasing TFTP block size for 2960 series switches

    I have read that some Cisco components can increase the default TFTP block size to values greater than 512 bytes by using the command -
    ip tftp blocksize xxxx
    This doesn't seem to be available on Cisco 2960 series switches. Is there a way to do this with the 2960's?

    I have moved a WS-C2960-24LC-S running LanLite to 12.2(55)SE9 - the current end of the line for this switch - and indeed the command is not present. Sooo....this appears to be a limitation of LanLite.
    My predecessor implemented about 70 switches with LanLite. I put a stop to this about a year ago but it is going to take some time to flush them out of the inventory.
    Thanks for your response.

  • Cisco 2960 series mismatch

    i have a switch, that shows next
    Switch Ports Model              SW Version            SW Image
    *    1 26    WS-C2960S-24TS-S   12.2(55)SE5           C2960S-UNIVERSALK9-M
    but!
    WS-C2960S-24TS-S <- what does this meen?
    what i ask about:
     catalist 2960 have 2960-S-series and simple 2960 (not S), and i hav'nt found WS-C2960 with S-suffix at http://www.cisco.com/c/en/us/products/switches/catalyst-2960-series-switches/models-comparison.html
    there is WS-* only without *S.
    what the device vertion is real and where can i find info about this device?

    I found the following info:
    "WS-C2960S-24TS-L is Lan Lite Switch.but WS-C2960S-24TS-S is the Lan Base. The obvious differences is hardware differences.The LAN Base owns advanced Layer 2 and mainly is designed for large enterprise. However, The LAN Lite offers entry-level L2 features ,which aims at mid market deployments."
    http://www.router-switch.com/ws-c2960s-24ts-s-p-1518.html

  • Nexus 2K to Cisco 2960 IOS Switch

    Hi,
    I am trying to connect Nexus 2K FEX to Cisco 2960 IOS Switch (Trunk config) and causing spanning tree loop having issues. I am aware that I should't be connecting non host port to 2K FEX but it's corner case. I have done similar setup with Access Port configuration and didn't faced any issues.
    Nexus 5K config Config 
    interface Ethernet107/1/47
      switchport mode trunk
      switchport trunk allowed vlan 500-501
      spanning-tree guard root
      spanning-tree bpdufilter enable 
    interface Ethernet108/1/47
      switchport mode trunk
      switchport trunk allowed vlan 500-501
      spanning-tree guard root
      spanning-tree bpdufilter enable 
    2960-Config 
    interface GigabitEthernet1/0/47
      switchport mode trunk
      switchport trunk allowed vlan 500-501
     spanning-tree bpdufilter enable
    interface GigabitEthernet1/0/48
      switchport mode trunk
      switchport trunk allowed vlan 500-501
     spanning-tree bpdufilter enable
    Error Log
    %FWM-2-STM_LOOP_DETECT: Loops detected in the network for mac 001b.1700.0130 among ports Eth107/1/47
    Eth108/1/47 vlan 500 - Disabling dynamic learn notifications for 180 seconds 
    Should I configure port as "spanning-tree port type network" and create VPC and "storm-control broadcast level" to stop future occurrence?  OR Do i have to configure anything else to prevent spanning-tree loops? 
    Thanks for your help
    Ritesh

    Hi,
    spanning-tree port type network is used for VPC peer-link.  Try creating a new VPC and add ports 107/1/47 and 108/1/47 to it and a Portchannel on the 2960 and test.
    HTH

  • Cisco MDS series switch details

    Hello I 'm new to CISCO  Switch world.
    I 'm working as Clariion Admin and have have taken up the responsibilty to manage switches.Since,i am a novice i need little guidance on how work on cisco switches.I know the Zoning (how zoning done on MDS 9000 series switches) part ,but would like to venture deep into the details on CISCO MDS series switches.
    Like, the use of Port channels etc.
    Will really appreciate if some one can help me with a link or place ( not the configuration guide) where in i can find details on concentrated more on the theory part .
    Thanks in advance!

    Actually the best info is in the configuration guides.  There are some external companies that run training sessions on the MDS to provide in depth training.  There is the MDS cookbook available on CCO that is also a good point of information.    If you search on 'MDS white papers' after you login into Cisco.com, there are several good documents that might meet your needs.
    Hope this hels,
    Mike

  • Cisco 4500 series switch

    Dear support taem, in cisco 4500 series switch i am getting error interface TenGigabitethernet 1/14 utlization threshold violated.current in traffic 705.228 (70.52 %) and out traffic 707.462 ( 70.75 %) whereas configured threshold is 30 %.
    i have checked on switch but qos is there in configuration.
    where i need to check if any restriction is there for incoming and outgoing traffic.
    and what necassery troubleshooting i need to be done.

    This looks like a policy shaping.

  • Cisco 4003 series switch

    Hi...All.
    In cisco 4003 series switch i m getting error in post test its says , rtc failed, after that supervisorengineer wxx4012 LED status is Red.can any one tell me wt that means and hw to solve that problem.

    plz fine the post test script...
    003-B-Ground> (enable) 0:00.523556: Please set IPAddr variable
    0:00.524147: Please set Netmask variable
    0:00.524511: Please set Broadcast variable
    0:00.525113: Please set TftpServer variable to do tftp downloads
    0:00.525658: Network is not configured
    WS-X4012 bootrom version 5.4(1), built on 2000.02.17 18:28:09
    H/W Revisions: Meteor: 4 Comet: 8 Board: 2
    Supervisor MAC addresses: 00:02:16:d2:5a:00 through 00:02:16:d2:5d:ff (1024 addr
    esses)
    Installed memory: 64 MB
    Testing LEDs.... done!
    The system will autoboot in 5 seconds.
    Type control-C to prevent autobooting.
    rommon 1 >
    The system will now begin autobooting.
    Autobooting image: "bootflash:cat4000.5-4-2.bin"
    CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
    CCCCCCCCCCCCCCCCCCCCCCCCCCC#############################
    Starting Off-line Diagnostics
    Mapping in TempFs
    Board type is WS-X4012
    DiagBootMode value is "post"
    Telling ApkPageMan that we have 12288 pages of memory
    Loading diagnostics...
    Power-on-self-test for Module 1: WS-X4012
    Status: (. = Pass, F = Fail)
    processor: . cpu sdram: . rtc: F
    eprom: . nvram: . flash: .
    temperature sensor: . enet console port: . switch port 0: .
    switch port 1: . switch port 2: . switch port 3: .
    switch port 4: . switch port 5: . switch port 6: .
    switch port 7: . switch port 8: . switch port 9: .
    switch port 10: . switch port 11: . switch registers: .
    switch sram: .
    Module 1 Failed
    Power-on-self-test for Module 2: not present
    Port status: (. = Pass, F = Fail)
    Module 2 Ignored
    Power-on-self-test for Module 3: not present
    Port status: (. = Pass, F = Fail)
    Module 3 Ignored
    Exiting Off-line Diagnostics
    Failed Module Bringup Process
    Use 'show test 1' to see results of tests.
    Cisco Systems, Inc. Console

  • Recovery missing or corrupted IOS of Cisco 2960 Catalyst Switch

    Dear Team,
    I have Cisco 2960 48P switch, It is keep getting restarted and config was erased.
    when I tried to run the IOS from hypertrm in room mode, I am getting below error..
    My doubt is, is there any issue with hardware & what is the cause of for below error 
    suggest me, is there any option to upgrade the IOS?
    switch: flash_init
    Initializing Flash...
    flashfs[0]: 0 files, 1 directories
    flashfs[0]: 0 orphaned files, 0 orphaned directories
    flashfs[0]: Total bytes: 32514048
    flashfs[0]: Bytes used: 1024
    flashfs[0]: Bytes available: 32513024
    flashfs[0]: flashfs fsck took 9 seconds.
    ...done Initializing Flash.
    switch: copy xmodem: flash:c2960-lanbasek9-mz.122-50.SE5.bin
    Begin the Xmodem or Xmodem-1K transfer now...
    CCCCBB0BB0................flashfs[0]: filesystem marked down.  Use "fsck" to rec
    over.
    flash:c2960-lanbasek9-mz.122-50.SE5.bin: interrupted system call
    switch:

    Error message means your BIN file is corrupt.  You need to download again from the Cisco website.

  • Cisco 500 series switches

    Dear support,
    Can Cisco 500 series switches deliver 24V on the access port for POE operation?
    Best Regards

    I belive the 802..2F and 802.2at poe standard is strictly 48v.  I haven't found anything to the contrary.  There are inline convertes 48v-24v or something like this that can be used with a non poe switch: http://www.digital-loggers.com/poe24.html but that means all conected device would be off the same access port / vlan. 

  • SNMPv3 on Cisco 2960-S Switch to NCS

    Can anyone point me to some good instructions on how to set up SNMPv3 on a Cisco Catalyst 2960-S switch in order to manage it with Cisco Prime NCS?

    here is link which explains snmp config for 2960s
    http://www.cisco.com/en/US/docs/switches/lan/catalyst2960/software/release/12.2_55_se/configuration/guide/swsnmp.html#wp1076836

  • Cisco 300 series switches with 802.3at standard

    I'm a bit confused as to which of the 300 series switches supports the 802.3at standard. According to the website, the SG300-28P supports it. But in the quick start guide for the 300 series, only the MP models (excluding the SF302-08MP and SG300-10MP) including the SG300-52P has it. Can someone give me a difinitive answer to this? Thanks!

    LJ,
    P    = PoE capable. On the 300 series, half of the ports can provide 15.4W, or all can provide half that.
    PoE+ is NOT SUPPORTED.
    MP = Maximum Power. This means that all ports can provide up to 15.4W. PoE+ is supported on some models only.
    PP = PoE Plus. Can provide up to 30W on a single port. Note the maximum PoE budget for each switch. Also,
    half of the ports can provide 15.4W, or all can provide half that - any extra power used by PoE+
    MPP = Maximum Power and PoE Plus. This means that all ports can provide up to 15.4W - any extra power used by PoE+
    According to the Data Sheet:
    "Switches support 802.3at PoE+, 802.3af, and Cisco pre-standard (legacy) PoE. Maximum power of 30.0W to any 10/100 or Gigabit Ethernet port for PoE+ supported devices and 15.4W for PoE supported devices, until the PoE budget for the switch is reached"
    The PoE+ models are brand new and are not widey available yet. I did a web search for SG300-28PP and found that at least a few online resellers have it in stock.
    - Marty
    Message was edited by: Martin Pyhala

  • Help for Cisco 2960 48port switch not working

    I had downloaded the template from the wiki for Cisco 48 port switch,unfortunately, it seems doesn't work.Are there other places where i can find WS-C2960S-48TS-L switch ? I also search the internet to find most people like to buy cisco product at Router-Switch.com with reliable quality and competitive price.Can give me the advice if i want to buy switch on this website ?

    Please read over this FAQ and see if any of it might apply to you.
    http://www.blackberryfaq.com/index.php/Errors_syncing_the_BB_with_Desktop_Manager
    1. If any post helps you please click the below the post(s) that helped you.
    2. Please resolve your thread by marking the post "Solution?" which solved it for you!
    3. Install free BlackBerry Protect today for backups of contacts and data.
    4. Guide to Unlocking your BlackBerry & Unlock Codes
    Join our BBM Channels (Beta)
    BlackBerry Support Forums Channel
    PIN: C0001B7B4   Display/Scan Bar Code
    Knowledge Base Updates
    PIN: C0005A9AA   Display/Scan Bar Code

  • Unable to hard code the ports of cisco 3750x series switch

    hello,
    I have tried with hardcode to 1000 7 Full on the ports which are connected to another switch.
    After changing the port to auto from one side of the switch port came up. Is there any solution to make port up when both sides are hard coded to 1000 & full duplex.
    Simple Words:
    Switch 1 --> Switch 2 --> Hard coded to 1000 & Full --> Down.
    Switch 1 --> Switch 2 --> Auto on one end to Switch 1  --> Up.
    Switch model:
    Switch 1 Cisco 3750x (Gi Switch)
    Switch 2 Cisco 3750 (Gi Switch)
    Regards,
    Ezra.

    Disclaimer
    The  Author of this posting offers the information contained within this  posting without consideration and with the reader's understanding that  there's no implied or expressed suitability or fitness for any purpose.  Information provided is for informational purposes only and should not  be construed as rendering professional advice of any kind. Usage of this  posting's information is solely at reader's own risk.
    Liability Disclaimer
    In  no event shall Author be liable for any damages whatsoever (including,  without limitation, damages for loss of use, data or profit) arising out  of the use or inability to use the posting's information even if Author  has been advised of the possibility of such damage.
    Posting
    Yes, it's possible without a straight through cable, enable auto/auto both sides.    Otherwise you'll need a cross-over cable.
    BTW, if your standard is hard coding copper gig ports, for speed and duplex, you might consider bringing your standard up to date.  Copper gig standard went much further in how auto/auto is supposed to work.  By disabling auto/auto, I believe, you're also disabling some error monitoring too.  Generally, all the major players, e.g. Cisco, would recommend auto/auto for copper gig Ethernet.

  • Cisco 300 series switches

    hi all
    Ive looked through some of the online content but dont see a definitive answer to my question about the physical size of the switches, are they all 19" rack mountable or desktop?
    I look forward to a confirmation..

    LJ,
    P    = PoE capable. On the 300 series, half of the ports can provide 15.4W, or all can provide half that.
    PoE+ is NOT SUPPORTED.
    MP = Maximum Power. This means that all ports can provide up to 15.4W. PoE+ is supported on some models only.
    PP = PoE Plus. Can provide up to 30W on a single port. Note the maximum PoE budget for each switch. Also,
    half of the ports can provide 15.4W, or all can provide half that - any extra power used by PoE+
    MPP = Maximum Power and PoE Plus. This means that all ports can provide up to 15.4W - any extra power used by PoE+
    According to the Data Sheet:
    "Switches support 802.3at PoE+, 802.3af, and Cisco pre-standard (legacy) PoE. Maximum power of 30.0W to any 10/100 or Gigabit Ethernet port for PoE+ supported devices and 15.4W for PoE supported devices, until the PoE budget for the switch is reached"
    The PoE+ models are brand new and are not widey available yet. I did a web search for SG300-28PP and found that at least a few online resellers have it in stock.
    - Marty
    Message was edited by: Martin Pyhala

  • Cisco 4500 series switch-Supervisor Engine.

    Is it possible to add two different supervisor engine module in a chassis(WS-C4507R+E Chassis)? (WS-X45-SUP7E in slot 3 and WS-X45-SUP6E-
    Redundancy in slot number 4)

    http://www.cisco.com/en/US/docs/switches/lan/catalyst4500/12.2/31sga/configuration/guide/RPR.html
    Redundancy requires both supervisor engines in the  chassis to be of the same supervisor engine model (same model, same  memory, NFL daughter card and so on), and to use the same Cisco IOS  software image.
    Thanks
    Hari.Sivaji

Maybe you are looking for

  • I have forgot my password.  My company changed emails and I can no longer get to the email address that was set up on my iPad.

    Ihave forgot my password to my account. ( I set a new one up to do this). When I go on to retrieve my password, it mails it to an email address I can no longer get to.    I always use the same combination of passwords, so I know it is something simpl

  • Can't simulate Clocking Wizard in ISE 14.7

    Hi! I have developed a simple design for a VGA module where I need to produce a 40Mhz clock out of 100Mhz input for an Artix-7 (XC7A100T-CSG324) on an Digilent Nexys4 evaluation board. In order to aquire this clock I have used a Clock Wizard for a DC

  • Ejb preinvoke errors after long periods of inactivity

    Hi, I have a basic 3-tier ee app -mysql 4.0 db on linux (with mySql's newest stable jdbc driver) -Sun AS 7.02 SE on Linux (rh9), running a J2EE application consisting of : -a number of entity beans -one stateless session bean (facade for entity beans

  • Free version - how to download/print as PDF

    New to the Forms Central tool and trying out the Free version.  I see in the "Features" section that you can download/save/print.  I can't figure out how to do that without upgrading.  Can someone help with how to do that?  I'm really just interested

  • I.d issue

    Hey guys, So i am in a total pickle, my blackberry user id has an invalid email, basically i messed up and put googlemail.co.uk instead of .com, this is now registered on my device, and having upgraded apps or ive been avoiding this as i had forgotte