Cisco 3925 Enhanced EtherSwitch Service Module

Hello all,
I have a Cisco 3925 router with a SM-ES3G-16-P Etherswitch module. In order for me to access it, I need to put an IP address on the phyiscal interface its attached to. Then I can access it via the service-module command.
My question is -- does it matter what address I give it? Does it need to be a legitimate management address on my network so that I can access it directly from another switch? Or do I always need to go through the router and issue the service-module command? If I do need to always go through the router, I should just be able to give it a 10.10.10.1 address and that should be enough, right?
Thanks for your help in advance,
Bobby Grewal

Thanks Reza...one more question. how does the switch module actually talk to the 3925 router? Through port 17 or 18? If so, do I need to configure those interfaces as routed ports within the same subnet? Or are they just trunks? All connections within the switching module would need to talk to outside devices.

Similar Messages

  • How to configure link between 2921 and SM-D-ES3G-48-P EtherSwitch Service Module

    hi,
    I can't do that like the procedure given by Cisco.
    http://www.cisco.com/en/US/partner/docs/routers/access/interfaces/software/feature/guide/eesm_sw.html#wp1942894
    Cisco Procedure :
    interface gi10/0
    ip address x.x.x.x x.x.x.x
    service-module gigabitethernet 1/0 session
    My result :
    R2921-8CPITR-1(config)#int gi 1/1
    R2921-8CPITR-1(config-if)#ip address 2.2.2.2 255.255.255.192
    % IP addresses may not be configured on L2 links.
    R2921-8CPITR-1(config-if)
    R2921-8CPITR-1(config)#interface gigabitEthernet 1/1.1 ?
    % Unrecognized command
    R2921-8CPITR-1(config)#interface gigabitEthernet 1/1 ?
      <cr>
    R2921-8CPITR-1(config)#
    the session is not possible also ?
    R2921-8CPITR-1#service-module gigabitEthernet 1/1 sess
                                                      ^
    % Invalid input detected at '^' marker.
    R2921-8CPITR-1#
    The routeur said that it's not a L3 port, so how to configure it to allow communication between the 2921 and the card ?
    Is there a bug with that version I'm in 15.1(4)M4 ????
    R2921-8CPITR-1#sh ver
    Cisco IOS Software, C2900 Software (C2900-UNIVERSALK9-M), Version 15.1(4)M4, RELEASE SOFTWARE (fc1)
    Technical Support: http://www.cisco.com/techsupport
    Copyright (c) 1986-2012 by Cisco Systems, Inc.
    Compiled Tue 20-Mar-12 18:57 by prod_rel_team
    ROM: System Bootstrap, Version 15.0(1r)M15, RELEASE SOFTWARE (fc1)
    R2921-8CPITR-1 uptime is 19 hours, 21 minutes
    System returned to ROM by power-on
    System restarted at 16:00:45 GAB Fri Sep 14 2012
    System image file is "flash0:c2900-universalk9-mz.SPA.151-4.M4.bin"
    Last reload type: Normal Reload
    This product contains cryptographic features and is subject to United
    States and local country laws governing import, export, transfer and
    use. Delivery of Cisco cryptographic products does not imply
    third-party authority to import, export, distribute or use encryption.
    Importers, exporters, distributors and users are responsible for
    compliance with U.S. and local country laws. By using this product you
    agree to comply with applicable laws and regulations. If you are unable
    to comply with U.S. and local laws, return this product immediately.
    A summary of U.S. laws governing Cisco cryptographic products may be found at:
    http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
    If you require further assistance please contact us by sending email to
    [email protected].
    Cisco CISCO2921/K9 (revision 1.0) with 479232K/45056K bytes of memory.
    Processor board ID FGL1618119E
    6 Gigabit Ethernet interfaces
    2 terminal lines
    DRAM configuration is 64 bits wide with parity enabled.
    255K bytes of non-volatile configuration memory.
    250880K bytes of ATA System CompactFlash 0 (Read/Write)
    License Info:
    License UDI:
    Device#   PID                   SN
    *0        CISCO2921/K9          FGL1618119E
    Technology Package License Information for Module:'c2900'
    Technology    Technology-package           Technology-package
                  Current       Type           Next reboot
    ipbase        ipbasek9      Permanent      ipbasek9
    security      None          None           None
    uc            None          None           None
    data          None          None           None
    Configuration register is 0x2102
    R2921-8CPITR-1#

    Same issue here.
    I just waited a few minutes and the interface went down and back up, this time it was a L3 interface.
    My guess is that it was booting the switch module IOS, and it detected it until it was fully booted:
    Apr 11 05:26:52.091: %LINK-3-UPDOWN: Interface GigabitEthernet0/0, changed state to down
    Apr 11 05:26:52.091: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
    Apr 11 05:26:52.091: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
    Apr 11 05:26:52.091: %LINK-3-UPDOWN: Interface GigabitEthernet1/0, changed state to up
    Apr 11 05:26:52.795: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
    Apr 11 05:26:53.091: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/0, changed state to down
    Apr 11 05:26:53.091: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
    Apr 11 05:26:53.091: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
    Apr 11 05:26:53.091: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0, changed state to up
    Apr 11 05:27:46.895: %LINK-5-CHANGED: Interface Embedded-Service-Engine0/0, changed state to administratively down
    Apr 11 05:27:46.895: %LINK-5-CHANGED: Interface GigabitEthernet0/0, changed state to administratively down
    Apr 11 05:27:46.947: %LINK-5-CHANGED: Interface GigabitEthernet0/1, changed state to administratively down
    Apr 11 05:27:47.031: %LINK-5-CHANGED: Interface GigabitEthernet0/2, changed state to administratively down
    Apr 11 05:27:47.083: %LINK-5-CHANGED: Interface GigabitEthernet1/0, changed state to administratively down
    Apr 11 05:27:47.895: %LINEPROTO-5-UPDOWN: Line protocol on Interface Embedded-Service-Engine0/0, changed state to down
    Apr 11 05:27:48.083: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0, changed state to down
    Apr 11 05:27:49.283: %IP-5-WEBINST_KILL: Terminating DNS process
    Apr 11 05:27:52.499: %LINK-3-UPDOWN: Interface GigabitEthernet1/1, changed state to up
    Apr 11 05:27:53.087: %SYS-5-RESTART: System restarted --
    Cisco IOS Software, C2951 Software (C2951-UNIVERSALK9-M), Version 15.1(4)M5, RELEASE SOFTWARE (fc1)
    Technical Support: http://www.cisco.com/techsupport
    Copyright (c) 1986-2012 by Cisco Systems, Inc.
    Compiled Tue 04-Sep-12 16:50 by prod_rel_team
    Apr 11 05:27:53.255: %SNMP-5-COLDSTART: SNMP agent on host Router is undergoing a cold start
    Apr 11 05:27:53.499: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1, changed state to up
    Apr 11 05:28:21.435: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to up
    Apr 11 05:29:22.091: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1, changed state to down
    Apr 11 05:29:22.095: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
    Router>en
    Router#sh ip int brief
    Interface                  IP-Address      OK? Method Status                Protocol
    Embedded-Service-Engine0/0 unassigned      YES unset  administratively down down
    GigabitEthernet0/0         unassigned      YES unset  administratively down down
    GigabitEthernet0/1         unassigned      YES unset  administratively down down
    GigabitEthernet0/2         unassigned      YES unset  administratively down down
    GigabitEthernet1/0         unassigned      YES unset  administratively down down
    GigabitEthernet1/1         unassigned      YES unset  up                    down
    Vlan1                      unassigned      YES unset  down                  down
    Router#
    Apr 11 05:29:46.106: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1, changed state to upconf t
    Enter configuration commands, one per line.  End with CNTL/Z.
    Router(config)#int g1/0
    Router(config-if)#ip add 1.1.1.1 255.255.255.0
    Router(config-if)#no shut
    Router(config-if)#
    Apr 11 05:30:09.046: %LINK-3-UPDOWN: Interface GigabitEthernet1/0, changed state to up
    Apr 11 05:30:10.046: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0, changed state to up
    Router(config-if)#end

  • Two etherswitch service module in same chassis

    I need to connect two NME-X-23ES-!G in the same chassis (Cisco 3845) and i have the following troubleshooting:
    1.- The numbers of the ports of both cards are identical. They are 1/0/2 to 1/0/24 for both modules. It would not have to change the first number depending on in which slot is inserted the card?
    2.- How I can configure the router for being able to arrive at both modules with the same VLAN. If I configure Etherchannel I cannot configure a IP address for the interface g1/0 or g2/0. If I do not have IP address I cannot make a session to switch module.
    3.- If I use the connect command I cannot use slot number 1 of routers because it leaves a message which not this supported. What I can do for being able to use it?

    Hello,
    I think you need to configure stacking for both modules, here is what CCO says:
    Configuring Stacking
    Stacking is the connection of two switch modules resident in the same chassis so that they behave as a single switch. When a chassis is populated with two switch modules, the user must configure both of them to operate in stacked mode. This is done by selecting one port from each switch module and configuring it to be a stacking partner. The user must then connect with a cable the stacking partners from each switch module to physically stack the switch modules. Any one port in a switch module can be designated as the stacking partner for that switch module.
    Beginning in privileged EXEC mode, follow these steps to configure a pair of ports on two different switch modules as stacking partners.
    SUMMARY STEPS
    1. interface fastethernet interface-id
    2. no shutdown
    3. switchport stacking-partner interface FastEthernet partner-interface-id
    4. exit
    5. interface fastethernet partner-interface-id
    6. no shutdown
    7. end
    HTH,
    GP

  • Service-module g2/0 session access fails

    I did not add a vty/telnet password when I initially configured my NME-X-23ES-1G switch in my 3825 router. Now, of course I can not telnet to the switch, but the session access fails as well. How do I recover this?
    Config in 3825:
    interface GigabitEthernet2/0
    ip address 106.40.x.x.255.255.0
    Attempt to access switch module:
    3825_Router2#service-module g2/0 sess
    Trying 106.40.77.254, 2130 ...
    % Connection refused by remote host

    The default configuration for Cisco EtherSwitch service modules allows an end user to recover from a lost password. The password recovery disable feature allows the system administrator to protect access to the switch password by disabling part of this functionality and allowing the user to interrupt the boot process only by agreeing to set the system back to the default configuration. With password recovery disabled, the user can still interrupt the boot process and change the password, but the configuration file (config.text) and the VLAN database file (vlan.dat) are deleted.
    The following document shows how to recover from a lost or forgotten password.
    http://www.cisco.com/en/US/products/hw/modules/ps2797/products_feature_guide09186a0080415bae.html#wp1776357

  • Service Module is failed

    when i show service-module ids-sensor 1/0 status
    i have the following output
    Service Module is Cisco IDS-Sensor1/0
    Service Module supports session via TTY
    Service Module is failed
    Service Module status is not available
    what is the problem and how can i recover it?
    note i make restart for the service module by the command
    service-module ids-snsor 1/0 reset
    but it remain failed
    please help me as soon as possible

    You've powered off and re-seated the card and this was working at one point?  Beyond that, if there is no output from the CUE console (while connected to the module via "service-module service-engine 0/1 session"), then the module is likely defective.

  • Service Module is trying to recover from error - Please help

    HI Guys
    I am currently installing a NM-AIR -WLC 6  wireless module in a 2811 and its giving me the follwing errors below and status
    I have checked the troubleshooting pdf and says might be possible hardware error ,but before i go down that road would like to know if any of the engineers have solved this problem
    Info about router and module is as follows
    Router#service-module wlan-controller 1/0 status
    Service Module is Cisco wlan-controller1/0
    Service Module supports session via TTY line 66
    Service Module is trying to recover from error
    Service Module status is not available
    Router#
    Trying to reset Service Module wlan-controller1/0
    *Mar 28 21:49:06.379: %LINEPROTO-5-UPDOWN: Line protocol on Interface wlan-controller1/0, changed state to down
    *Mar 28 21:49:26.379: %LINEPROTO-5-UPDOWN: Line protocol on Interface wlan-controller1/0, changed state to up
    Router#
    Router#service-module wlan-controller 1/0 status
    Service Module is Cisco wlan-controller1/0
    Service Module supports session via TTY line 66
    Service Module is trying to recover from reset/shutdown
    Service Module status is not available
    sh version
    Router#sh ver  
    Cisco IOS Software, 2800 Software (C2800NM-ADVIPSERVICESK9-M), Version 12.4(15)T17, RELEASE SOFTWARE (fc2)
    Technical Support: http://www.cisco.com/techsupport
    Copyright (c) 1986-2012 by Cisco Systems, Inc.
    Compiled Tue 24-Jan-12 07:41 by prod_rel_team
    ROM: System Bootstrap, Version 12.3(8r)T7, RELEASE SOFTWARE (fc1)
    Router uptime is 28 minutes
    System returned to ROM by power-on
    System image file is "flash:c2800nm-advipservicesk9-mz.124-15.T17.bin"
    This product contains cryptographic features and is subject to United
    States and local country laws governing import, export, transfer and
    use. Delivery of Cisco cryptographic products does not imply
    third-party authority to import, export, distribute or use encryption.
    Importers, exporters, distributors and users are responsible for
    compliance with U.S. and local country laws. By using this product you
    agree to comply with applicable laws and regulations. If you are unable
    to comply with U.S. and local laws, return this product immediately.
    A summary of U.S. laws governing Cisco cryptographic products may be found at:
    http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
    If you require further assistance please contact us by sending email to
    [email protected].
    Cisco 2811 (revision 53.51) with 249856K/12288K bytes of memory.
    Processor board ID FCZ0932701R
    2 FastEthernet interfaces
    1 Serial(sync/async) interface
    1 terminal line
    1 Virtual Private Network (VPN) Module
    1 cisco Wireless LAN Controller(s)
    DRAM configuration is 64 bits wide with parity enabled.
    239K bytes of non-volatile configuration memory.
    62720K bytes of ATA CompactFlash (Read/Write)
    Configuration register is 0x2102
    Router#

    HI Guys
    And it gets worse I am now getting the following error
    Router#service-module wlan-controller 1/0 status
    Service Module is Cisco wlan-controller1/0
    Service Module supports session via TTY line 66
    Service Module is failed
    Service Module status is not available
    regards Thags Govender

  • Cisco 3925 and SFP modules

    I'm trying to install a MGBSX1 into the Cisco 3925 but it's doesn't seem it's detecting it for some reason.
    I've changed media type and I've tested with another SFP module (GLC-SX-MM) which works fine.
    Am I missing a command to enable this type of module on the Cisco 3925?
    Thanks

    Hi,
    Looking at the SFP compatability table for 39XX series routers.
    http://www.cisco.com/c/en/us/products/routers/3900-series-integrated-services-routers-isr/relevant-interfaces-and-modules.html#formfactor
    The MGBSX1 is NOT mentioned
    Looks like the MGBSX1 is only compatable with the Small Business switch family.
    http://www.cisco.com/c/dam/en/us/td/docs/interfaces_modules/csbna/mgb/quick_start/guide/Optical_Module_QSG_en-US.pdf
    Regards
    Alex

  • Cisco 3560 service module failed state

    Hi Expert,
    My office has a Cisco 2911 ISR router, we installed a 3560 service module 16P on it.
    But I use command "sh ip int bri" in 2911 router when we finished installation.
    The result shows that the interface Gi 1/1 doesn't work, I have try to re-install SM 16P twice, the result is the same.
    The normal 2911 ISR + 3560 SM 16P show as below,
    2911#sh ip int brief 
    Interface                  IP-Address      OK? Method Status                Protocol
    Embedded-Service-Engine0/0 unassigned      YES NVRAM  administrativelwy down down 
    GigabitEthernet0/0         xxx.xxx.xxx.xxx     YES manual up                    up      
    GigabitEthernet0/1         xxx.xxx.xxx.xxx     YES NVRAM  up                    up      
    GigabitEthernet0/2         unassigned           YES NVRAM  down                  down    
    GigabitEthernet1/0         xxx.xxx.xxx.xxx      YES NVRAM  up                    up      
    GigabitEthernet1/1         unassigned           YES unset  up                    up
    The BAD 2911 ISR + 3560 SM 16P show as below,
    2911#sh ip int brief
    Interface                  IP-Address      OK? Method Status                Protocol
    GigabitEthernet0/0         xxx.xxx.xxx.xxx    YES NVRAM  up                    up
    GigabitEthernet0/1         unassigned          YES NVRAM  administratively down down
    GigabitEthernet0/2         unassigned          YES NVRAM  administratively down down
    GigabitEthernet1/0         unassigned          YES NVRAM  administratively down down

    Hi Krishnendu,
    I understand what you mean, I have done this work for assign Gi 1/0 an IP address, and then using command "service-module gi 1/0 session" to enter the service-module to configure it at all.
    But I just want to know what is the Gi1/1 interface used for?
    I use command "sh cdp nei" on others 2911 ISR + 3560 service module, all of the has the Gi 1/1 interface, and 2911 router using Gi 1/1 interface connected service module Gi 0/17. And Gi 1/1, Gi 0/17 is configured with "trunk interface".
    I'm wondering whether my 2911 router Gi 1/1 has some physics error? or maybe it has another command to to "OPEN" the Gi 1/1 on 2911?
    The "normal" switch display as below,
    rtr001#sh cdp neighbors 
    Capability Codes: R - Router, T - Trans Bridge, B - Source Route Bridge
                      S - Switch, H - Host, I - IGMP, r - Repeater, P - Phone, 
                      D - Remote, C - CVTA, M - Two-port Mac Relay 
    Device ID        Local Intrfce     Holdtme    Capability  Platform  Port ID
    swt000.nneas.net
                     Gig 1/0           129             R S I  SM-ES3G-1 Gig 0/18
    swt000.nneas.net
                     Gig 1/1           129             R S I  SM-ES3G-1 Gig 0/17
    Thanks in advance,
    BR Frank

  • Cisco SSL Services Module (on 6500)

    Hi all,
    A customer has asked me a few questions on an SSL Services Module they have (that we haven't sold and have little experience with). I've been reading the documents, but I have some questions and things to verify...
    As I can understand, they already have services and trustpoints configured on the module, but with certificates created with a previously-existing internal AD-integrated CA. Now, they want to switch their services to run a certificate they've obtained from a legitimate CA.
    1) They are trying to import the new certificate with copy-paste method, through the terminal. As far as I can see, both the server certificate and the CA certificate issuing the server cert. should be in base64 encoded for this to work, right? Or, can we import somehow PKCS or PEM certs thorough the terminal?
    2) They would like to use a wildcard certificate for a few of their servers/services they publish. (Like, instead of getting 3 different certificates for service1.domain.com, service2.domain.com and service3.domain.com, they'd like a certificate for *.domain.com which would work for all of the 3 services.) Is this possible? Should they need to change their configuration? (Now I understand that they have different trustpoints, certificates and service configurations for each of the servers...)
    I'd really like if some good soul with experience could shed a little light on this...
    Or, any leads on documentation (that I may have missed) would also be appreciated.
    Thanks in advance,
    Emre

    Good day Emre-
      For question 1 - You can import PEM base64 certificates via the terminal only, all other types need to be loaded over tftp/sftp/ftp. 
      For question 2 - There is nothing special about how the SSLM handles the Issed To field in a certificate, it doesn't matter if it is specifc or wildcard.  Multi domain certificates are also ok (using a Subject Alternative Name field.)  The only thing I can think of here in terms of a difference is you might have less trustpoints and configuration on you SSLM since you no longer require multiple server certificates.
    Outiside of your direct questions, make sure you upload the root and intermediate(s) into the SSLM.  It has to be able to complete the SSL chain from server to root in order to operate.
    Regards,
    Chris Higgins

  • Firewall service module vs ASA

    Hi
    Someone told me that the cisco firewall service module of 6500 has poor performances compared to ASA
    What do you recommend as a core firewall (to protect internal servers): ASA or firewall service module ?
    thanks

    Hi,
    We are using 5 FWSMs at the moment but are moving away from them to ASA5585-X models.
    I wouldnt suggest going to FWSMs anymore at this point if you have any plan on having support for new features.
    End Of Life and End of Sale Notice
    http://www.cisco.com/en/US/prod/collateral/modules/ps2706/eol_c51-699134.html
    The follower for the FWSM is the ASA Service Module which supports the newer softwares (while the FWSM doesnt). Heres a link to a document about the ASASM
    http://www.cisco.com/en/US/prod/collateral/modules/ps2706/ps11621/data_sheet_c78-672507.html
    Also you could always consider a separate ASA models. Here are links to both the orignal ASA 5500 series and new ASA 5500-X series
    ASA 5500 Series
    http://www.cisco.com/en/US/prod/collateral/vpndevc/ps6032/ps6094/ps6120/prod_brochure0900aecd80285492.pdf
    ASA 5500-X Series
    http://www.cisco.com/en/US/prod/collateral/vpndevc/ps6032/ps6094/ps6120/at_a_glance_c45-701635.pdf
    I guess the question for you is what are the requirements for the device regarding performance. All of the above documentation should give you a clue about which model might be the best for you.
    - Jouni

  • VPN service module choice 7600-SSC-400 vs. SPA-IPSEC-2G

    Need to decide between the two VPN service module: 7600-SSC-400 and SPA-IPSEC-2G for a 6509 sup 720 3bxl. Not sure what is the difference and couldnt find too much info just searching the internet. What would be the benefits of one or another?

    Hello,
    You will need both. The 7600-SSC-400 is the carrier module of the SPA-IPSec-2G.
    There is more information on this via the following link:
    http://www.cisco.com/en/US/docs/interfaces_modules/shared_port_adapters/configuration/6500series/76ovwvpn.html
    Warm Regards,
    Rose

  • ASA Service module shut down and on automatically

    hello,
    i have a asa service module which is inserted on 6509 chassis.
    This morning when i came to the office i have noticed my asa service module was restarted at last night but 6509 was up.
    one more thing we dont have failover.only have single asa service module.
    ASA SM version is 8.5
    below is the failover history and details
    ciscoasa up 17 hours 11 mins
    ------------------ show crashinfo ------------------
    No crash file found.
    ------------------ show failover history ------------------
    ==========================================================================
    <--- More --->
    From State                 To State                   Reason
    ==========================================================================
    14:28:40 UTC Apr 7 2013
    Not Detected               Disabled                   No Error
    can any one tell me why this happend.
    thanks in advanced
    Khem

    Hi,
    Would seem to me that it would be best to check this through Cisco TAC to determine the cause.
    It would seem though that no Crashinfo file was generated so thats kinda strange.
    You should be able to confirm if the ASASM is set to save a crashinfo file with the command "show crashinfo save"
    - Jouni

  • ASA Service Module on 6500 montoring console session

    We have 6500 with ASA Service Module
    On 6500 how can we configure so that if someone logs in to the ASA Service Module and reboots the firewall we can have logs of it in syslog of switch .
    Thanks for help

    I hate to answer my own posts, but here it is.  TAC tells us that there are 2 choices to make this work.  Apparently the way that worked on an ISR and ISRG2 does not work on the 4000 series routers.  I guess that's progress.
    Option 1. Use a physical cable to connect one of the router's interfaces to one of the etherswitches interfaces and treat it just like the etherswitch is a seperate physical switch.  I'm sure there is a use case for that but I'll not cover that here.
    Option 2. Use the "service instance" feature on the router's internal interface to bind it to a new "BDI" virtual interface on the router.  This is what we'll do.
    On our router ethernet-internal 1/0/0 maps to Gi0/18 on the etherswitch, all internal to the box.  The router will be10.0.0.1 and the switch will be 10.0.0.2.
    Router:
    interface Ethernet-Internal 1/0/0
    service instance 1 ethernet
    encapsulation dot1q 50
    rewrite ingress tag pop 1
    interface BDI 1
    mtu 9216
    ip address 10.0.0.1 255.255.255.0
    Switch:
    interface Gi0/18
    switchport trunk vlan allowed 50
    switchport mode trunk
    vlan 50
    name Egress vlan
    interface vlan 50
    ip address 10.0.0.2 255.255.255.0
    ip route 0.0.0.0 0.0.0.0 10.0.0.1
    Then there are a million ways to design and configure the switch as a normal 3560X switch but that's beyond the scope of my question.

  • RME 4.3.1 Inventory collection failing for cisco 3925

    Hi,
    I've a customer having LMS 3.2 and RME 4.3.1. He has 14 Cisco 3925 routers out of which inventory collection for 2 fails.
    Router IOS is: c3900-universalk9-mz.SPA.150-1.M.bin".
    Can someone suggest what might be going wrong? Attached is the  IC_Server log file for reference.
    Thanks in advance,
    inner_silence

    Hi,
    Here are the exception found from the log :-
    [ Fri Mar 18  16:28:24 EDT 2011 ],ERROR,[Thread-17],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,729,Exception for device 10.103.251.12 is
    java.lang.reflect.InvocationTargetException
        at sun.reflect.GeneratedMethodAccessor12.invoke(Unknown Source)
        at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:25)
        at java.lang.reflect.Method.invoke(Method.java:585)
        at com.cisco.nm.rmeng.inventory.ics.core.CollectionController.run(CollectionController.java:719)
        at java.lang.Thread.run(Thread.java:595)
    Caused by: com.cisco.nm.xms.xdi.ags.system.CollectionFailed: java.lang.StringIndexOutOfBoundsException: String index out of range: 2
        at com.cisco.nm.xms.xdi.pkgs.LibInventory.EnergyWise_HelperMethods.getDeviceEnergyWise(EnergyWise_HelperMethods.java:72)
        at com.cisco.nm.xms.xdi.pkgs.SharedInventoryCatIOS.EnergyWiseAGI_ENERGYWISE_Mib.g$eval(EnergyWiseAGI_ENERGYWISE_Mib.java:51)
        at com.cisco.nm.xms.xdi.ags.EnergyWiseAGI.g$eval(EnergyWiseAGI.java:21)
        at com.cisco.nm.xms.xdi.SdiEngine.initAndEvalAGIs(SdiEngine.java:383)
        at com.cisco.nm.xms.xdi.SdiEngine.request(SdiEngine.java:309)
        at com.cisco.nm.xms.xdi.SdiEngine.getDevRepr(SdiEngine.java:302)
        at com.cisco.nm.rmeng.inventory.ics.core.CollectionController.run(CollectionController.java:539)
        ... 1 more
    [ Fri Mar 18  16:28:24 EDT 2011 ],ERROR,[Thread-17],com.cisco.nm.rmeng.inventory.ics.core.CollectionController,761, Collection failed for the device : 63
    com.cisco.nm.xms.xdi.ags.system.CollectionFailed: java.lang.StringIndexOutOfBoundsException: String index out of range: 2
    Kindly check if the your device is running the required IOS on the device as per the device supported list :-
    http://www.cisco.com/en/US/docs/net_mgmt/ciscoworks_lan_management_solution/3.2/device_support/table/lms32sdt.html
    There are two 3925 listed with different versions :-
    Cisco 3925 Integrated Services Router   --> 1.3.6.1.4.1.9.1.1042  --> 15.0(1)M [RME]. if this is your device then upgrade to
    3925 to 150-1.M2
    and
    Cisco 3925E Integrated Services Router  --> 1.3.6.1.4.1.9.1.1144 --> 15.1(1)T
    Thanks,
    Gaganjeet
    If this post answers your question, please click the "Correct Answer" button

  • CUE "Service Module is failed"

                       Dears , i am getting this error on CUE .I reload the router but result is same .what should i do now?? ..
    #service-module service-engine 0/1 status
    Service Module is Cisco Service-Engine0/1
    Service Module supports session via TTY line 258
    Service Module is failed
    Service Module status is not available
    Regards,
    Shib

    You've powered off and re-seated the card and this was working at one point?  Beyond that, if there is no output from the CUE console (while connected to the module via "service-module service-engine 0/1 session"), then the module is likely defective.

Maybe you are looking for

  • Trying to upgrade from 10.4.11 to 10.5.8

    I'm working on restoring my computer after replacing a bad hard drive (G5 see below)... Machine Name: Power Mac G5   Machine Model: PowerMac7,3   CPU Type: PowerPC G5  (3.0)   Number Of CPUs: 1   CPU Speed: 1.8 GHz   L2 Cache (per CPU): 512 KB   Memo

  • How to deal with complex SOAP responses when calling web services ???

    Hi all, I have an issue when calling a web service that returns a complex SOAP response message. With simple responses (e. g. array of strings) it worked. I created the PDF as an Interactive form with Livecycle Designer 8.2. The Javascript looks like

  • Firewire and camera Canon

    hi , my iMac 20'' with iLife '08 bought in december 2008 can't see the Canon MV400 camcorder ( I use the firewire 6 pin to mac and 4 pin to camera ; I have 2 port on my iMac: FireWire 6 pin and FireWire 800); on a Mac+iLife '06 of my friend the camer

  • PL Sql queries

    1. How to display hiredate from an emp table where deptno is 20 as dd/mon/yyy? My Solution:Select hiredate from emp where hiredate ('dd/mm/yyyy') and deptno=20; 2. How to display ename from emp table who joined the company other then 1981? My Solutio

  • TS1717 hi , i have been playing draw something on my iphone 4s

    Hi, I have been playing draw something on my ophone 4s successfully until today when I tried to access the draw free app the screen was/is black please help i m addicted to the game thanks Jeff